ES100 - ELECTRICAL - LEVEL 06 - NEW WORK - SPECIAL SYSTEMS.pdf
PDF 650 KB Posted
- Attached to
- Y1DA--508-22-105 | 6th Floor CLC 16-Bed Bldg. C
- Solicitation number
- 36C24725R0029
About this file
This is an Electrical - Special Systems drawing for a renovation project at the VA Medical Center in Decatur, Georgia. The document details the electrical and special systems work for the 6th floor renovation, which includes creating a 16-bed Short Stay Clinical Logistics Center (CLC). The drawing shows a comprehensive floor plan with detailed electrical specifications, including nurse call systems, access control, telecommunications infrastructure, and various room-specific electrical requirements.
Key technical details include provisions for new fiber optic cabling, relocation of existing access control panels, replacement of card readers, and specific requirements for cable support systems, fire-rated pathways, and telecommunications outlet installations. The project involves complex special systems integration, with notes emphasizing coordination with VA representatives, proper cable management, labeling conventions, and adherence to specific technical standards for telecommunications and electrical infrastructure. The document is part of 100% construction documents issued on 9/21/2023 for the VA Office of Construction and Facilities Management.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CR
CR
C R
CRCR
CR
CR
C R
C R
N C
L
N C
L
N C
L
N C
L
N C
L
N C
L
N C
L
N C
L
N C
L
N C
L
N C
L
N C
L
N C
L
N C
L
N C
L
N C
L
NZL NZL
NZLNZL
NZL NZL NZL NZL
NZL
NEC
NZL
NEC NEC NEC NEC NEC NEC NEC NEC
NECNEC
NECNECNECNECNECNEC
NEC NEC NEC NEC NEC NEC NEC
NECNEC
NECNECNECNECNECNEC
N P
N P
N P
N P
N P
N P
N P
N P
N P
N P
N P
N P
N P
N P
N P
WAP
WAP
WAP
NZL
NZL
K P
C R
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
ND
NMS
ND
N C
L
N E
CN
E
C
N P
CR
CR
K P
C R
133 4 5 6 7 8 9 10 11 12
D
E
F
G
GYM
HAC
ELEV
S-6
ELEV
S-5
STAIR 1
CHART
ELEC.
C.L.
ELEC.
BATH
S.U.
665AHAC
665B
ELEC
TLT.
TLT.
GYM STOR.
O.T. STORAGE
PATIENT 1
PATIENT 2
TLT 1
TLT 2-2
607-2
PATIENT 3-2
609-2
TLT 3
DINING
PATIENT 4-2
612-2
PATIENT 9
TLT 4
TLT 9-1
615-1
PATIENT 10-3
616-3
PATIENT 11-2
619-2
PATIENT 12-3
620-3
TLT 10
TLT 11
CORRIDOR-2
6C63-2
EQUIP.
STORAGE
CORRIDOR-2
6C63-2
ELEV
P-13
ELEV
P-14
HALLWAY
STAIR
S.U.
C.U.
MED.
ELEV
P-3
ELEV
P-4
TLT
D A
T A
ELEV. LOBBY
ELEC
ELEC
ELEV
P-1
ELEV
P-2
SOILED PANT.
CLEAN PANT.
HUDDLE
OFFICE
COPY
TLT.
TLT.
LOCKERS
BREAK
CONFERENCE
PATIENT 5
PATIENT 6
PATIENT 7
PATIENT 8-2
634-2
TLT 8
633TLT 7-2
636-2
TLT 6
TLT 5
OFFICE
LAUNDRY
CORRIDOR
6C60
CORRIDOR
6C60
CORRIDOR
6C60
LIVING
CHAT ROOM-2
630-2
REC ROOM
PATIENT 13-2
628-2
PATIENT 14
PATIENT 15
PATIENT 16
CORRIDOR
6C66
TV
54"
54"AFF
TV
TV
54"AFF
54"AFF
54"AFF
54"AFF
54"AFF 54"AFF54"AFF 54"AFF
54"AFF
54"AFF54"AFF54"AFF54"AFF54"AFF54"AFF
54"AFF
12"x4" 12"x4"
12"x4" 12"x4"
"x
"x
12"x4" 4"ø
4"ø
4"ø
4"ø
12"x4"
54"AFF
S 180
S 180
S 360
S 360
S
S 180
MS
S 360
S 180
ACCESS CONTROL
NURSE CALL
ES100
ES100
8 8
NEW WORK GENERAL NOTES
NOTE
AN "IT" PRE-SUBMITTAL MEETING WILL BE REQUIRED
PRIOR TO SUBMITTAL REVIEW WITH VA "IT" REPRESENTATIVE
AND AE. CONTRACTOR TO COORDINATE WITH
CONTRACTING OFFICER'S REPRESENTATIVE 14 DAYS PRIOR
TO MEETING.
A. REFER TO SHEET E002 FOR SPECIAL SYSTEMS SYMBOLS, SCHEDULES
AND NOTES.
B. THE EXIT POINT OF ALL CONDUIT/SLEEVES POSITIONED HORIZONTALLY
MUST BE FITTED WITH A CONDUIT WATERFALL TYPE SUPPORT SYSTEM
SUCH AS THE PANDUIT CWF 400, OR APPROVED EQUIVALENT, TO
CONTROL THE BEND RADIUS OF THE COMMUNICATION CABLE TO A
MINIMUM OF A 4" RADIUS.
C. ALL OUTLET LOCATIONS ARE IN APPROXIMATE POSITIONS. THE EXACT
LOCATIONS SHALL BE DETERMINED BY PROVIDED BOX LOCATIONS AND
FIELD CONDITIONS. ALL LOCATIONS SHALL BE FIELD VERIFIED PRIOR TO
ROUGH IN.
D. AN INDEPENDENT SUPPORT SUBSYSTEM FASTENED TO STRUCTURAL
STEEL SHALL BE CREATED FOR THE STRUCTURED CABLING SYSTEM.
CABLING SHALL BE SUPPORTED EVERY FOUR (4) TO FIVE (5) FEET
WHEN EXITING BOTH HORIZONTAL AND VERTICAL RACEWAYS.
E. ALL THRU WALL OR THRU FLOOR PENETRATIONS AS WELL AS ANY
CONDUIT PATHWAYS USED FOR THE STRUCTURED CABLING SYSTEM
SHALL BE EITHER RETURNED TO THEIR NORMAL ORIGINAL INTEGRITY,
IF THAT ORIGINAL CONDITION WAS DEFICIENT, IT SHALL BE BROUGHT
UP TO STANDARDS, OR SHALL BE MADE WHOLE BY USE OF AN
APPROPRIATE FIRE-RATED SYSTEM. ALL TELECOMMUNICATIONS
SLEEVES FOR THIS PROJECT SHALL BE FIRE STOPPED. ALL EXTERIOR
ENTRANCE CONDUITS SHALL BE PLUGGED WITH A WATER PROOF
PLUG.
F. ALL OUTLET LOCATIONS SHALL BE IDENTIFIED WITH A TIA/EIA 606-A
COMPLIANT LABELING SYSTEM. LABELING CONVENTIONS SHALL BE
APPROVED BY THE OWNER PRIOR TO ORDERING LABELS. PROVIDE A
LAMINATED 30" X 42" AS-BUILT DOCUMENT SHOWING ALL LABELS AT
EACH OUTLET. THE DOCUMENT SHALL BE FRAMED AND POSTED IN THE
TELECOM ROOM.
G. ALL DRAWINGS ARE DIAGRAMMATIC. CONTRACTOR SHALL PROVIDE
COORDINATION DOCUMENTS IN ACCORDANCE WITH THE
SPECIFICATIONS. ADDITIONAL TRANSITIONS REQUIRED DUE TO FIELD
CONDITIONS ARE THE RESPONSIBILITY OF THE CONTRACTOR.
H. ELECTRICAL DEVICES PROVIDED IN DIVISION 26 ARE SHOWN FOR
COORDINATION PURPOSES ONLY.
I. A PROPOSED CABLE TRAY ROUTING IS SHOWN TO ILLUSTRATE A
FEASIBLE ROUTE BASED ON KNOWN OBSTACLES AND HAS BEEN
COORDINATED WITH OTHER DISCIPLINES. CONTRACTOR SHALL SHALL
PROVIDE AS-BUILT, BIM COORDINATED DRAWINGS TO BE DISCUSSED AT
THE "IT" PRESUBMITTAL MEETING. ROUTING SHALL BE COORDINATED IN
FIELD WITH OTHER TRADES.
KEY PLAN: (NOT TO SCALE)
AREA OF WORK
OUTLET INSTALLED IN WALL MOUNTED FURNITURE SYSTEM.
WALL PLATE FINISH SHALL BE BLACK OR STAINLESS STEEL
TO COORDINATE WITH FURNITURE FINISH.
PROVIDE WALL OUTLET FOR WALL MOUNTED PHONE.
COORDINATE EXACT LOCATION WITH ARCHITECTURAL
PLANS AND SIGNAGE.
PROVIDE 2-4" CONDUITS ABOVE ARCHITECTURAL CEILING
FOR TELECOMMUNICATIONS WIRING.
THE OWNER SHALL REMOVE EXISTING ACTIVE
ELECTRONICS FROM THE EXISTING TELECOM RACK.
COORDINATE WITH THE VA CONTRACTING OFFICER'S
REPRESENTATIVE REGARDING THE REUSE OF THE EXISTING
ACTIVE ELECTRONICS AND ANY NEW REQUIRED
EQUIPMENT/HARDWARE.
CONTRACTOR SHALL PROVIDE FIRE RATED PATHWAY WITH
THREE (3) - 4" OPENING FOR PASSAGE OF CABLING
THROUGH RATED WALL.
PROVIDE NEW FIBER OPTIC CABLE FROM ROOM 2C271 FOR
CONNECTION TO THE NEW JERON 790 NURSE CALL SYSTEM.
USE EXISTING LAN SWITCH PROVIDED FOR FUTURE USE.
CONNECT GATEWAY FOR LEVEL 06 TO THE EXISTING NURSE
CALL NURSE CALL GATEWAYS ON LEVEL 08 AND LEVEL 09
FOR REMOTE SURVIVABILITY.
EXISTING ACCESS CONTROL PANELS SHALL BE RELOCATED
TO THE LOCATION SHOWN. CONTRACTOR SHALL PROVIDE
ALL WIRING AND INTEGRATION TO MAKE SYSTEM WHOLE
AND FUNCTIONAL.
REPLACE EXISTING CARD READER. REUSE EXISTING
RACEWAY TO THE EXTENT FEASIBLE. CONTRACTOR SHALL
PROVIDE ALL WIRING, ACCESSORIES, AND PROGRAMMING
TO MAKE THE SYSTEM FUNCTIONAL AND ACCEPTABLE TO
THE VA CONTRACTING OFFICER'S REPRESENTATIVE.
NEW WORK KEYED NOTES
EXISTING 42U TELECOMMUNICATIONS RACK.
EXISTING KEYED NOTES
NURSE CALL
ACCESS CONTROL
6 7
2 HR FIRE RATED
1 HR FIRE RATED
1 HR SMOKE BARRIER
SMOKE PARTITION
2 HR SMOKE BARRIER
3 HR SMOKE BARRIER
WALL RATING LEGEND
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
Engineering Discipline:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
U D
B e n d e r\ L o c a l R e v it F ile s \2
\4
V A
M C
A tl a n ta th f l\
C E
C e n tr a l M o d e l.
rv t
/5 /2
:1
:3
P M
ES100
ELECTRICAL - LEVEL 06 - NEW
WORK - SPECIAL SYSTEMSCHARLOTTE ENGINEERS
5838 MONROE ROAD, SUITE 100
CHARLOTTE, NC 28212
704.531.3000
GUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS STREET
317.800.6388
RENOVATE 6TH FLOOR FOR 16
BED STORT STAY CLC
1670 CLAIRMONT RD, DECATUR, GA
508-22-105
C
9/21/2023 JCE NMG
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
1/8" = 1'-0"
ELECTRICAL - LEVEL 06 - NEW WORK - SPECIAL SYSTEMS
GRAPHIC SCALE
( in Feet )
1 inch = 8 ft.
8 84 16 32
1/4" = 1'-0"ES100
2 SPECIAL SYSTEMS - DATA 682
1/4" = 1'-0"ES100
3 SPECIAL SYSTEMS - ELEC ROOM 664
Revisions: Date:
Addendum 2 05-06-2025
NOT A CERTIFIED DOCUMENT AS TO THE ORIGINAL DOCUMENT
BUT ONLY AS TO THE REVISION - THIS DOCUMENT ORIGINALLY
ISSUED AND SEALED BY JOHN C. EDWARDS, JR. 050482, 09-21-23
THIS DOCUMENT IS ONLY CERTIFIED AS TO THE REVISIONS.
| Sheets |
| E001 - ELECTRICAL - LEGENDS, SYMBOLS, AND DRAWING INDEX |
| E004 - ELECTRICAL - SPECIAL SYSTEM DETAILS |
| E005 - ELECTRICAL - SPECIAL SYSTEM DETAILS |
| E006 - ELECTRICAL - PARTIAL RISER DIAGRAMS |
| E007 - ELECTRCIAL - PANEL SCHEDULES |
| ED100 - ELECTRICAL - LEVEL 06 - DEMOLITION |
| ES100 - ELECTRICAL - LEVEL 06 - NEW WORK - SPECIAL SYSTEMS |