Building 43.pdf

PDF 5 MB Posted

Attached to
Z2DA--590-19-106 Bathroom Upgrades Federal contract opportunity
Solicitation number
36C24621R0018
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6

About this file

This document outlines a federal contract opportunity for bathroom upgrades at a Veterans Affairs medical center. The Department of Veterans Affairs, Veterans Integrated Service Network 6 is seeking a contractor to provide all labor, tools, and materials for bathroom upgrades at their Hampton, Virginia campus. The estimated construction value is between $2,000,000 to $5,000,000. The solicitation is set aside for Total Service-Disabled Veteran Owned Small Businesses. Interested vendors should register on the website to receive any amendments or notices, and must have active SAM and VetBiz registrations to be eligible for award. Questions must be emailed to the point of contact by the specified date. The scope of work involves architectural, interior finishes, and mechanical, electrical, and plumbing work throughout the facility in accordance with provided drawings and specifications.

View the file

Other files for this federal contract opportunity

Other files attached to Z2DA--590-19-106 Bathroom Upgrades, newest first.
File Type Posted
Renovate Bathrooms Rev 1 Slab Details R.pdf PDF
138A P101.pdf PDF
02 82 00 HVAMC Bathroom Renovation Asbestos Lead Based Paint Survey.pdf PDF
36C24621R0018_2 0005.docx DOCX document
M600 5.pdf PDF
VAMC Site Map Laydown Area.pdf PDF
138A-P101.pdf PDF
36C24621R0018_2 0003.docx DOCX document
M600.pdf PDF
VAMC Site Map - Laydown Area.pdf PDF
36C24621R0018_2 0004.docx DOCX document
36C24621R0018_2 0002.docx DOCX document
Hampton VAMC Bathroom Renovation Asbestos _ Lead Based Paint Survey - (F).pdf PDF
Building 138A - Site Analysis.pdf PDF
Building 114 - Floor 1 - Site AnalysisR.pdf PDF
Building 114 - Floor 2 - Site AnalysisR.pdf PDF
Building 110B - Site Analysis.pdf PDF
Building 110 - Site Analysis.pdf PDF
Building 137 - Site Analysis.pdf PDF
Building 52 - Site Analysis.pdf PDF
Building 110A - Site Analysis.pdf PDF
Building 37 - Site Analysis.pdf PDF
Building 36 - Site Analysis.pdf PDF
Building 116 - Site Analysis.pdf PDF
Building 146 Area B - Site Analysis.pdf PDF
Building 33 - Site Analysis.pdf PDF
Building 135 - Site Analysis.pdf PDF
Drawing 151 - 307.pdf PDF
Drawing 101 - 150.pdf PDF
Drawing 1-50.pdf PDF
36C24621R0018_2 0001.docx DOCX document
Drawing 51-100.pdf PDF
Attachment A - Base Proposal Item Price Breakdown.xlsx XLSX spreadsheet
Bathroom Upgrade Spec Book.pdf PDF
Attachment C - Past Performance Questionnaire.docx DOCX document
Safety Handbook.pdf PDF
36C24621R0018_2.docx DOCX document
Attachment B - Corp Experience Form.docx DOCX document
Show all 38

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VAMC - HAMPTON

BATHROOM UPGRADES

Project No. ADG18003.00

BUILDING 43

OVERALL

ROOM 104

ROOM 111F

ROOM 113

ROOM 202

ROOM 203

ROOM 204

February 28, 2019

AD

G

3.

BATHROOM UPGRADES| HAMPTON, VIRGINIA

02.28.19

BUILDING 43

3.

EXTEND WALL TO

ACCOMMODATE

GRAB BAR AND

TOILET CLEAR FLOOR

SPACE

REMOVAL OF THIS STALL WOULD

BRING THIS SPACE CLOSER

TO BEING ADA COMPLIANT BUT

WOULD OFFSET BUILDING CODE

FIXTURE COUNT

3.

IN ORDER TO MAKE THE SPACE ADA

COMPLIANT - A TOILET AND 2 SINKS

WOULD HAVE TO BE REMOVED. THIS

WOULD OFFSET THE BUILDING CODE

3.

3.

3.

3.

3.

ACCOMMODATE

CLEAR FLOOR

SPACE FOR DOOR

APPROACH

THIS SPACE IS A

SHOWER ROOM BUT

CURRENTLY IS BEING

USED FOR STORAGE.

3.

3.

3.

3.

3.

3.

3.

3.

THIS SPACE

IS NOT ADA

COMPLIANT

3.

3.

ACCOMMODATE

GRAB BAR AND

TOILET CLEAR FLOOR

SPACE

REMOVAL OF THIS STALL WOULD

BRING THIS SPACE CLOSER

TO BEING ADA COMPLIANT BUT

WOULD OFFSET BUILDING CODE

3.

IN ORDER TO MAKE THE SPACE ADA

COMPLIANT - A TOILET AND 2 SINKS

WOULD HAVE TO BE REMOVED. THIS

WOULD OFFSET THE BUILDING CODE

3.

3.

BUILDING 43 SUMMARY

ROOM 104*, 111F, 113 (Shower room - No Toilets), 202, 204*

The clearances meet ADA Requirements

ROOM 203

The clearances do not meet ADA requirements.

AS DIRECTED BY THE VA, BATHROOMS THAT CANNOT MEET

ACCESSIBILITY REQUIREMENTS WILL ONLY RECEIVE NEW

FINISHES AND FIXTURES

*ROOM 104, 204

In order to make these bathrooms accessible the fixture count was reduced.

File details come from the government source that posted it. Updated .