Building 114 - Floor 1 - Site AnalysisR.pdf
PDF 2 MB Posted
- Attached to
- Z2DA--590-19-106 Bathroom Upgrades Federal contract opportunity
- Solicitation number
- 36C24621R0018
About this file
This document includes a site analysis report and federal contract opportunity notice. The site analysis report provides existing and proposed layouts for 17 bathrooms in Building 114 at the Hampton VA Medical Center, identifying clearance issues in several rooms that would require wall modifications to meet ADA and VA accessibility standards. The related federal contract opportunity is a solicitation from the Department of Veterans Affairs for bathroom upgrade projects at the Hampton VA campus with an estimated value between $2-5 million. As a Total Service-Disabled Veteran-Owned Small Business set-aside, it requires current SAM and VetBiz registrations. The general scope of work involves architectural, interior finishes, MEP, and associated work in accordance with provided drawings and specifications. The point of contact is listed for any questions.
View the file
Other files for this federal contract opportunity
Show all 38
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VAMC - HAMPTON
BATHROOM UPGRADES
Project No. ADG18003.00
BUILDING 114 - First Floor
OVERALL FIRST FLOOR
ROOM AG02
ROOM AG07A
ROOM BG05A
ROOM BG06A
ROOM BG07A
ROOM BG08A
ROOM BG09A
ROOM BG013A
ROOM BG014A
ROOM BG015A
ROOM BG016A
ROOM BG017A
SUMMARY BUILDING 114
December 12, 2018
AD
G
3.
BATHROOM UPGRADES| HAMPTON, VIRGINIA
12.07.18
BUILDING 114
3.
EXISTING
3.
PROPOSED
WALL NEEDS
TO BE
WIDENED
TO MEET 30”
REQUIREMENT
FOR
CLEARANCE
OF SINK
3.
3.
3.
WALL NEEDS
TO BE
WIDENED
TO MEET 30”
REQUIREMENT
FOR
3.
3.
3.
3.
3.
3.
WALL NEEDS
TO BE
WIDENED
TO MEET 30”
REQUIREMENT
FOR
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
WALL NEEDS
TO BE
WIDENED
TO MEET 30”
REQUIREMENT
FOR
3.
3.
3.
WALL NEEDS
TO BE
WIDENED
TO MEET 30”
REQUIREMENT
FOR
3.
3.
3.
WALL NEEDS
TO BE
WIDENED
TO MEET 30”
REQUIREMENT
FOR
3.
3.
3.
WALL NEEDS
TO BE
WIDENED
TO MEET 30”
REQUIREMENT
FOR
3.
3.
3.
WALL NEEDS
TO BE
WIDENED
TO MEET 30”
REQUIREMENT
FOR SHOWER
WIDTH
WALL NEEDS
TO BE
WIDENED
TO MEET 30”
CLEARANCE
REQUIREMENT
FOR SINK
3.
3.
BUILDING 114 - FIRST FLOOR - SUMMARY
ROOM AG02
The clearances meet minimum ADA requirements (2010 ADA Standards). Does not meet requirements based on the VA Barrier Free Design Standards.
ROOM AG07A
The clearances meet minimum ADA requirements (2010 ADA Standards). Does not meet requirements based on the VA Barrier Free Design Standards.
ROOM BG05A, BG07A, BG08A, BG09A
The clearances meet minimum ADA requirements (2010 ADA Standards). Does not meet requirements based on the VA Barrier Free Design Standards.
ROOM BG06A, BG13A, BG14A, BG15A, BG16A
The clearances around the sink do not meet ADA requirements (2010 ADA Standards) The walls surrounding the sink would need to be widened.
ROOM BG17A
The clearances around the sink do not meet ADA requirements (2010 ADA Standards) The walls surrounding the sink would need to be widened. The width of the shower does need meet ADA requirements and needs to be widened.
AS DIRECTED BY THE VA, BATHROOMS THAT CANNOT MEET
ACCESSIBILITY REQUIREMENTS WILL ONLY RECEIVE NEW
FINISHES AND FIXTURES.
File details come from the government source that posted it. Updated .