Building 135 - Site Analysis.pdf

PDF 3 MB Posted

Attached to
Z2DA--590-19-106 Bathroom Upgrades Federal contract opportunity
Solicitation number
36C24621R0018
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6

About this file

This document includes a site analysis report and federal contract opportunity notice. The site analysis report provides existing and proposed layouts for 10 bathrooms in Building 135 at the Hampton VA Medical Center, identifying which can and cannot be modified to meet ADA accessibility requirements. The related federal contract opportunity is solicitation number 36C24621R0018 for bathroom upgrade work at the Hampton VAMC with an estimated value between $2 million and $5 million. As a total SDVOSB set-aside, the opportunity is only open to verified Service-Disabled Veteran-Owned Small Businesses. Interested vendors should monitor the website for amendments and direct any questions to the point of contact by email only.

View the file

Other files for this federal contract opportunity

Other files attached to Z2DA--590-19-106 Bathroom Upgrades, newest first.
File Type Posted
Renovate Bathrooms Rev 1 Slab Details R.pdf PDF
138A P101.pdf PDF
02 82 00 HVAMC Bathroom Renovation Asbestos Lead Based Paint Survey.pdf PDF
36C24621R0018_2 0005.docx DOCX document
M600 5.pdf PDF
VAMC Site Map Laydown Area.pdf PDF
138A-P101.pdf PDF
36C24621R0018_2 0003.docx DOCX document
M600.pdf PDF
VAMC Site Map - Laydown Area.pdf PDF
36C24621R0018_2 0004.docx DOCX document
36C24621R0018_2 0002.docx DOCX document
Hampton VAMC Bathroom Renovation Asbestos _ Lead Based Paint Survey - (F).pdf PDF
Building 43.pdf PDF
Building 138A - Site Analysis.pdf PDF
Building 114 - Floor 1 - Site AnalysisR.pdf PDF
Building 114 - Floor 2 - Site AnalysisR.pdf PDF
Building 110B - Site Analysis.pdf PDF
Building 110 - Site Analysis.pdf PDF
Building 137 - Site Analysis.pdf PDF
Building 52 - Site Analysis.pdf PDF
Building 146 Area B - Site Analysis.pdf PDF
Building 33 - Site Analysis.pdf PDF
Building 110A - Site Analysis.pdf PDF
Building 37 - Site Analysis.pdf PDF
Building 36 - Site Analysis.pdf PDF
Building 116 - Site Analysis.pdf PDF
Drawing 151 - 307.pdf PDF
Drawing 101 - 150.pdf PDF
Drawing 51-100.pdf PDF
Drawing 1-50.pdf PDF
36C24621R0018_2 0001.docx DOCX document
Attachment A - Base Proposal Item Price Breakdown.xlsx XLSX spreadsheet
Safety Handbook.pdf PDF
36C24621R0018_2.docx DOCX document
Attachment B - Corp Experience Form.docx DOCX document
Bathroom Upgrade Spec Book.pdf PDF
Attachment C - Past Performance Questionnaire.docx DOCX document
Show all 38

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VAMC - HAMPTON

BATHROOM UPGRADES

Project No. ADG18003.00

BUILDING 135

OVERALL

ROOM AG05

ROOM AG07

ROOM AG17B

ROOM A101D1

ROOM A101E1

ROOM A106

ROOM A108

SUMMARY

February 01, 2019

AD

G

3.

BATHROOM UPGRADES| HAMPTON, VIRGINIA

02.01.19

BUILDING 135

3.

EXISTING

HEATER WOULD

NEED TO EITHER

BE REMOVED OR

RELOCATED IN THE

SPACE

3.

PROPOSED

LOCATION OF

DOOR NEEDS TO BE

MOVED TO BE ADA

COMPLIANT

3.

3.

3.

REMOVAL OF THE 2ND SINK

BRINGS THE BATHROOM

CLOSER TO BEING ADA

COMPLIANT AND DOES

NOT AFFECT THE BUILDING

CODE

APPROACH TO THE

DOOR NEEDS TO

BE WIDENED TO BE

ADA COMPLIANT.

WALL NEEDS TO BE

SHIFTED TO ALLOW

FOR APPROPRIATE

SPACE.

3.

3.

3.

THIS ROOM CANNOT BE

MADE ADA ACCESSIBLE.

ALL MANEUVERING

CLEARANCES DO NOT FIT.

3.

3.

3.

3.

3’-0” DOOR DOES NOT FIT IN

THIS SPACE.

THIS ROOM CANNOT BE

MADE ADA ACCESSIBLE.

3.

3.

3.

THIS ROOM CANNOT BE

MADE ADA ACCESSIBLE.

3.

3.

3.

APPROACH TO THE DOOR NEEDS TO BE

WIDENED TO BE ADA COMPLIANT. WALL

NEEDS TO BE SHIFTED OVER 1’ TO ALLOW

FOR APPROPRIATE SPACE.

NEW FIXTURE

PLACEMENT

ALLOWS FOR

SPACE TO BE

ADA COMPLIANT.

3.

3.

3.

APPROACH TO THE DOOR

NEEDS TO BE WIDENED

TO BE ADA COMPLIANT.

WALL NEEDS TO BE

SHIFTED OVER 1’ TO

ALLOW FOR APPROPRIATE

SPACE.

NEW FIXTURE PLACEMENT ALLOWS

FOR SPACE TO BE ADA COMPLIANT

WITHOUT REMOVING ANY COLUMNS

3.

3.

BUILDING 135 SUMMARY

ROOM AG05, AG07, A106, A108

These rooms can be modified to meet ADA requirements.

ROOM AG17B, A101D1, A101E1,

These rooms do not meet ADA requirements.

PER IBC: BATHROOMS OFF PRIVATE OFFICES ARE NOT

REQUIRED TO BE ACCESSIBLE.

AS DIRECTED BY THE VA, BATHROOMS THAT CANNOT MEET

ACCESSIBILITY REQUIREMENTS WILL ONLY RECEIVE NEW

FINISHES AND FIXTURES