About this file

This document contains details for a federal contract opportunity for bathroom upgrades at a Veterans Affairs medical center campus. The Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 6 is seeking a contractor to provide all labor, tools, and materials to upgrade bathrooms throughout the facility located in Hampton, Virginia. The estimated construction value is between $2,000,000 to $5,000,000. This opportunity is set aside for Total Service-Disabled Veteran Owned Small Businesses. Interested vendors must register on the website to receive any amendments and ensure their SAM and VetBiz registrations are current and active to be eligible for award. Questions regarding this solicitation must be emailed to the point of contact by the specified date.

View the file

Other files for this federal contract opportunity

Other files attached to Z2DA--590-19-106 Bathroom Upgrades, newest first.
File Type Posted
M600 5.pdf PDF
VAMC Site Map Laydown Area.pdf PDF
Renovate Bathrooms Rev 1 Slab Details R.pdf PDF
138A P101.pdf PDF
02 82 00 HVAMC Bathroom Renovation Asbestos Lead Based Paint Survey.pdf PDF
36C24621R0018_2 0005.docx DOCX document
138A-P101.pdf PDF
36C24621R0018_2 0003.docx DOCX document
M600.pdf PDF
VAMC Site Map - Laydown Area.pdf PDF
36C24621R0018_2 0004.docx DOCX document
36C24621R0018_2 0002.docx DOCX document
Building 37 - Site Analysis.pdf PDF
Building 36 - Site Analysis.pdf PDF
Building 116 - Site Analysis.pdf PDF
Hampton VAMC Bathroom Renovation Asbestos _ Lead Based Paint Survey - (F).pdf PDF
Building 43.pdf PDF
Building 138A - Site Analysis.pdf PDF
Building 114 - Floor 1 - Site AnalysisR.pdf PDF
Building 114 - Floor 2 - Site AnalysisR.pdf PDF
Building 110B - Site Analysis.pdf PDF
Building 110 - Site Analysis.pdf PDF
Building 137 - Site Analysis.pdf PDF
Building 52 - Site Analysis.pdf PDF
Building 146 Area B - Site Analysis.pdf PDF
Building 33 - Site Analysis.pdf PDF
Building 135 - Site Analysis.pdf PDF
Drawing 1-50.pdf PDF
36C24621R0018_2 0001.docx DOCX document
Drawing 151 - 307.pdf PDF
Drawing 101 - 150.pdf PDF
Drawing 51-100.pdf PDF
Bathroom Upgrade Spec Book.pdf PDF
Attachment C - Past Performance Questionnaire.docx DOCX document
Attachment A - Base Proposal Item Price Breakdown.xlsx XLSX spreadsheet
Safety Handbook.pdf PDF
36C24621R0018_2.docx DOCX document
Attachment B - Corp Experience Form.docx DOCX document
Show all 38

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VAMC - HAMPTON

BATHROOM UPGRADES

Project No. ADG18003.00

BUILDING 110A

February 12, 2019

ROOM CG50

ROOM CG52

ROOM CG54A

ROOM CG54B

ROOM C110

ROOM C112

ROOM C120

ROOM C146

ROOM C216C1

ROOM C216D

ROOM C216F

ROOM C231

ROOM C240

AD

G

3.

BATHROOM UPGRADES| HAMPTON, VIRGINIA

02.12.19

BUILDING 110A

FP00

3.

EXISTING

WALL NEEDS TO

BE REMOVED IN

ORDER TO HAVE

MANEUVERING

CLEARANCE IN

FRONT OF SHOWER

BATHROOM STALL

TO BE REMOVED TO

HAVE MANEUVERING

CLEARANCE

REMOVE

LOCKERS (3)

3.

PROPOSED

ACCESSIBLE

SHOWER WITH SEAT

RELOCATING SINK

TO ALLOW FOR

MANEUVERING

CLEARANCE

LOCKERS

3.

SHOWER FLOOR TO

BE LEVEL WITH REST

OF ROOM TO BE ADA

ACCESSIBLE

3.

LOCKERS TO BE

REMOVED

3.

THIS PORTION

OF THE WALL

WOULD NEED TO

BE DEMOLISHED

IN ORDER TO HAVE

AN ACCESSIBLE

SHOWER

DOOR SWING

NEEDS TO FLIP

TO HAVE PROPER

MANEUVERING

CLEARANCE

BATHROOM STALL

TO BE REMOVED TO

HAVE MANEUVERING

3.

BE LEVEL WITH REST

3.

3.

SHOWER TO BE

MOVED FORWARD

TO BE EVEN WITH

ADJACENT WALL.

ALLOWS FOR

MANEUVERING

CLEARANCE IN

FRONT OF SHOWER.

3.

3.

THIS PORTION

OF THE WALL

WOULD NEED TO

BE DEMOLISHED

IN ORDER TO HAVE

AN ACCESSIBLE

SHOWER

3.

BATHROOM STALL

TO BE REMOVED TO

HAVE MANEUVERING

3.

BE LEVEL WITH REST

3.

THIS PORTION

OF THE WALL

WOULD NEED TO

BE DEMOLISHED IN

ORDER TO HAVE A

3’-0” DOOR

3.

FIXTURES

RELOCATED TO MAKE

ADA ACCESSIBLE.

3.

3.

THIS PORTION OF

THE WALL TO BE

DEMOLISHED IN

ORDER TO HAVE A

3’-0” DOOR

BATHROOM STALL

TO BE REMOVED TO

ALLOW FOR PROPER

3.

3.

3.

3.

3.

3.

3.

REMOVAL OF 2ND SINK AND

URINAL BRINGS THIS ROOM

CLOSER TO BEING ADA

ACCISSIBLE BUT OFFSETS

THE BUILDING CODE FIXTURE

COUNT

3.

3.

3.

NO MANEUVERING

CLEARANCE FOR

TURN AROUND.

NO MANEUVERING

CLEARANCE FOR

DOOR APPROACH.

3.

3.

3.

NO MANEUVERING

CLEARANCE FOR

TURN AROUND.

NO MANEUVERING

CLEARANCE FOR

DOOR APPROACH.

3.

3.

3.

3.

3.

3.

3.

3.

THIS WALL TO

BE REMOVED TO

ALLOW FOR PROPER

CLEARANCE IN

BATHROOM

DRESSING ROOMS

TO BE REMOVED

TO ALLOW PROPER

3.

BENCH WITH ROD

ABOVE

PRIVACY CURTAIN

TO SEPARATE

BATHROOM FROM

DRESSING ROOM

PRIVACY CURTAIN

3.

3.

BUILDING 110A SUMMARY

ROOM CG54A*, CG54B, C110, C112, C120, C146**, C216F, C231, C240

The clearances meet ADA Requirements

* As long as the shower floors are able to be level with rest of bathroom - This room can be made ada accessible.

** This room can be made accessible but would lose a urinal and sink.

This would offset the building code fixture count.

ROOM CG50*, CG52*,

* As long as the shower floors are able to be level with rest of bathroom - This room can be made ada accessible.

To meet ADA requirements, All existing lockers cannot be accomodated in these spaces. (The lockers able to remain are on the proposed plans)

ROOM C216C1, C216D

The clearances do not meet ADA requirements.

AS DIRECTED BY THE VA, BATHROOMS THAT CANNOT MEET

ACCESSIBILITY REQUIREMENTS WILL ONLY RECEIVE NEW

FINISHES AND FIXTURES