This document outlines requirements for bathroom upgrades at the Hampton VA Medical Center in Hampton, Virginia. The solicitation seeks a contractor to provide all labor, tools, and materials for bathroom upgrades throughout the facility, including architectural and interior finishes work as well as mechanical, electrical, and plumbing work, as specified in the drawings and specifications. The estimated construction value is between $2 million and $5 million. The NAICS code for this project is 236220 with a size standard of $39.5 million. This solicitation is set aside as a total service-disabled veteran-owned small business opportunity. Interested vendors must register on the website provided and check for any amendments, with the response due date not specified. All registration must be current and active for award eligibility. Questions may only be submitted via email to the point of contact provided.
View the file
Other files for this federal contract opportunity
Show all 38
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VAMC - HAMPTON
BATHROOM UPGRADES
Project No. ADG18003.00
BUILDING 33 - SITE ANALYSIS
OVERALL FIRST FLOOR
ROOM 116
ROOM 117
ROOM 212
OVERALL SECOND FLOOR
SUMMARY BUILDING 33
November 7, 2018
AD
G
3.
BATHROOM UPGRADES| HAMPTON, VIRGINIA
10.17.18
BUILDING 33 - OVERALL
3.
BUILDING 33 - ROOM 116
3.
3.
3.
BUILDING 33 - ROOM 117
3.
3.
3.
3.
BUILDING 33 - ROOM 212
3.
3.
3.
BUILDING 33 SUMMARY
ROOM 116
Existing plan can not be made accessible, The removal of urinal and storage drawers does bring it closer to code compliance. The fixture layout is compliant, the door approach does not have the required maneuvering clearance.
ROOM 117
Existing plan can not be made accessible. The relocation of the sink does bring us closer to code compliance. The fixture layout is compliant but the door approach does not have the required maneuvering clearance.
ROOM 212
Existing plan can not be made accessible. Demolition of corner (column or chase) and wall off the window to provide wall space for second grab bar. The fixture layout is compliant but the door approach does not have the required maneuvering clearance.