This document is a Door Hardware specification for the Construct Consolidated Boiler Spaces project at the Loch Raven VA Medical Center. The specification covers detailed requirements for door hardware, including continuous hinges, door closers, locks, exit devices, electromagnetic locks, thresholds, and various accessories. Nine specific hardware sets are defined for different door types across multiple rooms (such as exterior panic doors, rated doors, toilet rooms, and storage areas), with each set listing precise hardware components from manufacturers like SARGENT, McKinney, Rockwood, and Pemko.
The specification provides extensive technical details on hardware installation, including precise mounting heights, hinge requirements, finish specifications, and compliance standards such as ANSI/BHMA, NFPA, and ADA. Notably, the document includes a requirement for all hardware to comply with the Architectural Barriers Act Accessibility Standard and mandates specific warranty periods for different hardware components. Each hardware set includes a caveat about potential waivers required to comply with the Buy American Act, indicating the project's federal nature and procurement constraints.
View the file
Other files
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Construct Consolidated Boiler Spaces Door Hardware Loch Raven VAMC 03-01-24
512-23-154
08 71 00-1
SECTION 08 71 00
DOOR HARDWARE
PART 1 - GENERAL
1.1 DESCRIPTION
Door hardware and related items necessary for complete installation and operation of doors.
1.2 RELATED WORK
Caulking: Section 07 92 00 JOINT SEALANTS.
Application of Hardware: Section 08 11 13, HOLLOW METAL DOORS AND FRAMES Section 08
71 13, AUTOMATIC DOOR OPERATORS Section 08 71 13.11, LOW ENERGY DOOR OPERATORS
Finishes: Section 09 06 00, SCHEDULE FOR FINISHES.
Painting: Section 09 91 00, PAINTING.
Card Readers: Section 28 13 00, PHYSICAL ACCESS CONTROL SYSTEMS.
Electrical: Division 26, ELECTRICAL.
Fire Detection: Section 28 31 00, FIRE DETECTION AND ALARM.
1.3 GENERAL
All hardware shall comply with ABAAS, (Architectural Barriers Act Accessibility Standard) unless specified otherwise.
Provide rated door hardware assemblies where required by most current version of the
International Building Code (IBC).
Hardware for Labeled Fire Doors and Exit Doors: Conform to requirements of NFPA 80 for labeled fire doors and to NFPA 101 for exit doors, as well as to other requirements specified. Provide hardware listed by UL, except where heavier materials, large size, or better grades are specified herein under paragraph HARDWARE SETS. In lieu of UL labeling and listing, test reports from a nationally recognized testing agency may be submitted showing that hardware has been tested in accordance with UL test methods and that it conforms to NFPA requirements.
Hardware for application on metal doors and frames shall be made to standard templates. Furnish templates to the fabricator of these items in sufficient time so as not to delay the construction.
The following items shall be of the same manufacturer, except as otherwise specified:
1. Mortise locksets.
2. Hinges for hollow metal and wood doors.
3. Surface applied overhead door closers.
4. Exit devices.
5. Floor closers.
1.4 WARRANTY
Automatic door operators shall be subject to the terms of FAR Clause 52.246-21, except that the
Warranty period shall be two years in lieu of one year for all items except as noted below:
1. Locks, latchsets, and panic hardware: 5 years.
512-23-154
08 71 00-2
2. Door closers and continuous hinges: 10 years.
1.5 MAINTENANCE MANUALS
In accordance with Section 01 00 00, GENERAL REQUIREMENTS Article titled
"INSTRUCTIONS", furnish maintenance manuals and instructions on all door hardware. Provide installation instructions with the submittal documentation.
1.6 SUBMITTALS
Submittals shall be in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. Submit 6 copies of the schedule per Section 01 33 23. Submit 2 final copies of the final approved schedules to VAMC Locksmith as record copies (VISN Locksmith if the VAMC does not have a locksmith).
Hardware Schedule: AHC certified hardware consultant to prepare and submit hardware schedule in the following form:
Hardware Item
Quantity Size Reference Publication Type No.
Finish Mfr.
Name and Catalog No.
Key Control Symbols
UL Mark (if fire rated and listed)
ANSI/BHMA
Finish Designation
Samples and Manufacturers' Literature:
1. Samples: All hardware items (proposed for the project) that have not been previously approved by Builders Hardware Manufacturers Association shall be submitted for approval.
Tag and mark all items with manufacturer's name, catalog number and project number.
2. Samples are not required for hardware listed in the specifications by manufacturer's catalog number, if the contractor proposes to use the manufacturer's product specified.
Certificate of Compliance and Test Reports: Submit certificates that hardware conforms to the requirements specified herein. Certificates shall be accompanied by copies of reports as referenced. The testing shall have been conducted either in the manufacturer's plant and certified by an independent testing laboratory or conducted in an independent laboratory, within four years of submittal of reports for approval.
Record of opening force measurement for all doors equipped with closers
1.7 DELIVERY AND MARKING
Deliver items of hardware to job site in their original containers, complete with necessary appurtenances including screws, keys, and instructions. Tag one of each different item of hardware and deliver to COR for reference purposes. Tag shall identify items by Project Specification number and manufacturer's catalog number. These items shall remain on file in COR's office until all other similar items
512-23-154
08 71 00-3 have been installed in project, at which time the COR will deliver items on file to Contractor for installation in predetermined locations on the project.
1.8 PREINSTALLATION MEETING
Convene a preinstallation meeting not less than 30 days before start of installation of door hardware. Require attendance of parties directly affecting work of this section, including Contractor and
Installer, Architect, Project Engineer and VA Locksmith, Hardware Consultant, and Hardware
Manufacturer’s Representative. Review the following:
1. Inspection of door hardware.
2. Job and surface readiness.
3. Coordination with other work.
4. Protection of hardware surfaces.
5. Substrate surface protection.
6. Installation.
7. Adjusting.
8. Repair.
9. Field quality control.
10. Cleaning.
1.9 INSTRUCTIONS
Hardware Set Symbols on Drawings: Except for protective plates, door stops, mutes, thresholds and the like specified herein, hardware requirements for each door are indicated on drawings by symbols.
Symbols for hardware sets consist of letters (e.g., "HW") followed by a number. Each number designates a set of hardware items applicable to a door type.
Keying: All cylinders shall be keyed into existing Grand Master Key System. Provide removable core cylinders that are removable only with a special key or tool without disassembly of knob or lockset.
Cylinders shall be 7 pin type. Keying information shall be furnished at a later date by the COR.
1.10 APPLICABLE PUBLICATIONS
The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only. In text, hardware items are referred to by series, types, etc., listed in such specifications and standards, except as otherwise specified.
ASTM International(ASTM):
F883-13 ...................................... Padlocks
E2180-18................Standard Test Method for Determining the Activity of Incorporated
Antimicrobial Agent(s) In Polymeric or Hydrophobic Materials
American National Standards Institute/Builders Hardware Manufacturers Association
(ANSI/BHMA):
A156.1-06 ................................... Butts and Hinges
A156.2-03 ................................... Bored and Pre-assembled Locks and Latches
512-23-154
08 71 00-4
A156.3-08 ................................... Exit Devices, Coordinators, and Auto Flush Bolts
A156.4-08 ................................... Door Controls (Closers)
A156.5-14 ................................... Cylinders and Input Devices for Locks.
A156.6-05 ................................... Architectural Door Trim
A156.8-05 ................................... Door Controls-Overhead Stops and Holders
A156.11-14 ................................. Cabinet Locks
A156.12-05 .............Interconnected Locks and Latches
A156.13-05 ................................. Mortise Locks and Latches Series 1000
A156.14-07 .............Sliding and Folding Door Hardware
A156.15-06 ................................. Release Devices-Closer Holder, Electromagnetic and
Electromechanical
A156.16-08 ................................. Auxiliary Hardware
A156.17-04 .............Self-Closing Hinges and Pivots
A156.18-06 ................................. Materials and Finishes
A156.20-06 .............Strap and Tee Hinges, and Hasps
A156.21-09 ................................. Thresholds
A156.22-05 ................................. Door Gasketing and Edge Seal Systems
A156.23-04 ................................. Electromagnetic Locks
A156.24-03 ................................. Delayed Egress Locking Systems
A156.25-07 .............Electrified Locking Devices
A156.26-06 ................................. Continuous Hinges
A156.28-07 .............Master Keying Systems
A156.29-07 .............Exit Locks and Alarms
A156.30-03 .............High Security Cylinders
A156.31-07 ................................ Electric Strikes and Frame Mounted Actuators
A156.36-10 ................................. Auxiliary Locks
A250.8-03 ................................... Standard Steel Doors and Frames
National Fire Protection Association (NFPA):
80-10 .......................................... Fire Doors and Other Opening Protectives
101-09 ........................................ Life Safety Code
Underwriters Laboratories, Inc. (UL):
Building Materials Directory (2008)
Architectural Barriers Act Accessibility Standards (ABAAS)
512-23-154
08 71 00-5
PART 2 - PRODUCTS
2.1 BUTT HINGES
ANSI A156.1. Provide only three-knuckle hinges, except five-knuckle where the required hinge type is not available in a three-knuckle version (e.g., some types of swing-clear hinges). The following types of butt hinges shall be used for the types of doors listed, except where otherwise specified:
1. Interior Doors: Type A8112/A5112 for doors 900 mm (3 feet) wide or less and Type
A8111/A5111 for doors over 900 mm (3 feet) wide. Hinges for doors exposed to high humidity areas (shower rooms, toilet rooms, kitchens, janitor rooms, etc. shall be of stainless steel material.
Provide quantity and size of hinges per door leaf as follows:
1. Doors up to 1210 mm (4 feet) high: 2 hinges.
2. Doors 1210 mm (4 feet) to 2260 mm (7 feet 5 inches) high: 3 hinges minimum.
3. Doors greater than 2260 mm (7 feet 5 inches) high: 4 hinges.
4. Doors up to 900 mm (3 feet) wide, standard weight: 114 mm x 114 mm (4-1/2 inches x 4-1/2 inches) hinges.
5. Doors over 900 mm (3 feet) to 1065 mm (3 feet 6 inches) wide, standard weight: 127 mm x
114 mm (5 inches x 4-1/2 inches).
6. Doors over 1065 mm (3 feet 6 inches) to 1210 mm (4 feet), heavy weight: 127 mm x 114 mm
(5 inches x 4-1/2 inches).
7. Provide heavy-weight hinges where specified.
8. At doors weighing 330 kg (150 pounds) or more, furnish 127 mm (5 inch) high hinges.
See Articles "MISCELLANEOUS HARDWARE" and "HARDWARE SETS" for pivots and hinges other than butts specified above and continuous hinges specified below.
2.2 CONTINUOUS HINGES
ANSI/BHMA A156.26, Grade 1-600.
1. Listed under Category N in BHMA's "Certified Product Directory."
General: Minimum 0.120-inch- (3.0-mm-) thick, hinge leaves with minimum overall width of 4 inches (102 mm); fabricated to full height of door and frame and to template screw locations; with components finished after milling and drilling are complete
Continuous, Barrel-Type Hinges: Hinge with knuckles formed around a Teflon-coated 6.35mm
(0.25-inch) minimum diameter pin that extends entire length of hinge.
1. Base Metal for Exterior Hinges: Stainless steel.
2. Base Metal for Interior Hinges: Steel.
3. Base Metal for Hinges for Fire-Rated Assemblies: Stainless steel.
4. Provide with non-removable pin (hospital tip option) at lockable outswing doors.
5. Where required to clear adjacent casing, trim, and wall conditions and allow full door swing, provide wide throw hinges of minimum width required.
512-23-154
08 71 00-6
6. Provide with manufacturer’s cut-outs for separate mortised power transfers and/or mortised automatic door bottoms where they occur.
7. Where thru-wire power transfers are integral to the hinge, provide hinge with easily removable portion to allow easy access to wiring connections.
8. Where models are specified that provide an integral wrap-around edge guard for the hinge edge of the door, provide manufacturer’s adjustable threaded stud and machine screw mechanism to allow the door to be adjusted within the wrap-around edge guard.
2.3 DOOR CLOSING DEVICES
Closing devices shall be products of one manufacturer.
2.4 OVERHEAD CLOSERS
Conform to ANSI A156.4, Grade 1.
Closers shall conform to the following:
1. The closer shall have minimum 50 percent adjustable closing force over minimum value for that closer and have adjustable hydraulic back check effective between 60 degrees and 85 degrees of door opening.
2. Where specified, closer shall have hold-open feature.
3. Size Requirements: Provide multi-size closers, sizes 1 through 6, except where multi-size closer is not available for the required application.
4. Material of closer body shall be forged or cast.
5. Arm and brackets for closers shall be steel, malleable iron or high strength ductile cast iron.
6. Where closers are exposed to the exterior or are mounted in rooms that experience high humidity, provide closer body and arm assembly of stainless steel material.
7. Closers shall have full size metal cover; plastic covers will not be accepted.
8. Closers shall have adjustable hydraulic back-check, separate valves for closing and latching speed, adjustable back-check positioning valve, and adjustable delayed action valve.
9. Provide closers with any accessories required for the mounting application, including (but not limited to) drop plates, special soffit plates, spacers for heavy-duty parallel arm fifth screws, bull-nose or other regular arm brackets, longer or shorter arm assemblies, and special factory templating. Provide special arms, drop plates, and templating as needed to allow mounting at doors with overhead stops and/or holders.
10. Closer arms or backcheck valve shall not be used to stop the door from overswing, except in applications where a separate wall, floor, or overhead stop cannot be used.
11. Provide parallel arm closers with heavy duty rigid arm.
12. Where closers are to be installed on the push side of the door, provide parallel arm type except where conditions require use of top jamb arm.
13. Provide all surface closers with the same body attachment screw pattern for ease of replacement and maintenance.
512-23-154
08 71 00-7
14. All closers shall have a 1 ½” (38mm) minimum piston diameter.
2.5 DOOR STOPS
Conform to ANSI A156.16.
Provide door stops wherever an opened door or any item of hardware thereon would strike a wall, column, equipment or other parts of building construction. For concrete, masonry or quarry tile construction, use expansion shields for mounting door stops.
Where cylindrical locks with turn pieces or pushbuttons occur, equip wall bumpers Type L02251
(rubber pads having concave face) to receive turn piece or button.
Provide floor stops (Type L02141 or L02161) in office areas; Type L02121 x 3 screws into floor elsewhere. Wall bumpers, where used, must be installed to impact the trim or the door within the leading half of its width. Floor stops, where used, must be installed within 4-inches of the wall face and impact the door within the leading half of its width.
Provide stop Type L02011, as applicable for exterior doors. At outswing doors where stop can be installed in concrete, provide stop mated to concrete anchor set in 76mm (3-inch) core-drilled hole and filled with quick-setting cement.
Omit stops where floor mounted door holders are required and where automatic operated doors occur.
Provide appropriate roller bumper for each set of doors (except where closet doors occur) where two doors would interfere with each other in swinging.
Provide appropriate door mounted stop on doors in individual toilets where floor or wall mounted stops cannot be used.
Provide door stops on doors where combination closer magnetic holders are specified, except where wall stops cannot be used or where floor stops cannot be installed within 4-inches of the wall.
Where the specified wall or floor stop cannot be used, provide concealed overhead stops (surface-mounted where concealed cannot be used).
2.6 OVERHEAD DOOR STOPS AND HOLDERS
Conform to ANSI Standard A156.8. Overhead holders shall be of sizes recommended by holder manufacturer for each width of door. Set overhead holders for 110 degree opening, unless limited by building construction or equipment. Provide Grade 1 overhead concealed slide type: stop-only at rated doors and security doors, hold-open type with exposed hold-open on/off control at all other doors requiring overhead door stops.
2.7 LOCKS AND LATCHES
Conform to ANSI A156.2. Locks and latches for doors 45 mm (1-3/4 inch) thick or over shall have beveled fronts. Lock cylinders shall have not less than six pins. Cylinders for all locksets shall be removable core type. Cylinders shall be furnished with construction removable cores and construction master keys. Cylinder shall be removable by special key or tool. Construct all cores so that they will be interchangeable into the core housings of all mortise locks, rim locks, cylindrical locks, and any other type
512-23-154
08 71 00-8 lock included in the Great Grand Master Key System. Disassembly of lever or lockset shall not be required to remove core from lockset. All locksets or latches on double doors with fire label shall have latch bolt with
19 mm (3/4 inch) throw, unless shorter throw allowed by the door manufacturer’s fire label. Provide temporary keying device or construction core to allow opening and closing during construction and prior to the installation of final cores.
In addition to above requirements, locks and latches shall comply with following requirements:
1. Mortise Lock and Latch Sets: Conform to ANSI/BHMA A156.13. Mortise locksets shall be series 1000, minimum Grade 2. All locksets and latchsets, except on designated doors in
Psychiatric (Mental Health) areas, shall have lever handles fabricated from cast stainless steel. Provide sectional (lever x rose) lever design matching [__________]. No substitute lever material shall be accepted. All locks and latchsets shall be furnished with 122.55 mm (4-
7/8-inch) curved lip strike and wrought box. At outswing pairs with overlapping astragals, provide flat lip strip with 21mm (7/8-inch) lip-to-center dimension. Lock function F02 shall be furnished with emergency tools/keys for emergency entrance. All lock cases installed on lead lined doors shall be lead lined before applying final hardware finish. Furnish armored fronts for all mortise locks. Where mortise locks are installed in high-humidity locations or where exposed to the exterior on both sides of the opening, provide non-ferrous mortise lock case.
2. Cylindrical Lock and Latch Sets: levers shall meet ADA (Americans with Disabilities Act) requirements. Cylindrical locksets shall be series 4000 Grade I. All locks and latchsets shall be furnished with 122.55 mm (4-7/8-inch) curved lip strike and wrought box. At outswing pairs with overlapping astragals, provide flat lip strip with 21mm (7/8-inch) lip-to-center dimension.
Provide lever design to match design selected by Architect or to match existing lever design.
Where two turn pieces are specified for lock F76, turn piece on inside knob shall lock and unlock inside knob, and turn piece on outside knob shall unlock outside knob when inside knob is in the locked position. (This function is intended to allow emergency entry into these rooms without an emergency key or any special tool.)
3. Auxiliary locks shall be as specified under hardware sets and conform to ANSI A156.36.
2.8 ELECTROMAGNETIC LOCKS
ANSI/BHMA A156.23; electrically powered, of strength and configuration indicated; with electromagnet attached to frame and armature plate attached to door. Listed under Category E in BHMA's
"Certified Product Directory."
1. Type: Full exterior or full interior, as required by application indicated.
2. Strength Ranking: 1500 pound force (6672 N).
3. Inductive Kickback Peak Voltage: Not more than 53 V.
4. Residual Magnetism: Not more than 4 pound force (18 N) to separate door from magnet.
Delayed-Egress Locks: BHMA A156.24. Listed under Category G in BHMA's "Certified Product
Directory".
512-23-154
08 71 00-9
1. Means of Egress Doors: Lock releases within 15 seconds after applying a force not more than
15 pound force (67 N) for not more than 3 seconds, as required by NFPA 101.
2. Security Grade: Activated from secure side of door by initiating device.
3. Movement Grade: Activated by door movement as initiating device.
4. The lock housing shall not project more than 4-inches (101mm) from the underside of the frame head stop.
2.9 ELECTRIC STRIKES
ANSI/ BHMA A156.31 Grade 1.
General: Use fail-secure electric strikes at fire-rated doors.
2.10 KEYS
Stamp all keys with change number and key set symbol. Furnish keys in quantities as follows:
Locks/Keys Quantity
Cylinder locks 2 keys each
Cylinder lock change key blanks 100 each different key way
Master-keyed sets 6 keys each
Grand Master sets 6 keys each
Great Grand Master set 5 keys
Control key 2 keys
Psychiatric keys shall be cut so that first two bittings closest to the key shoulder are shallow to provide greater strength at point of greatest torque.
2.11 KEY CABINET
ANSI Standard A156.11. Provide key cabinet made of cold rolled, 1.2 mm (0.0478 inch) thick furniture steel electro-welded. Doors shall have "no sag" continuous brass-pin piano type hinge and be equipped with chrome plated locking door handles, hook cam and mechanical pushbutton door lock. Key
Cabinet and Key Control System shall accommodate all keys for this project plus 25 percent. Provide minimum number of multiple cabinets where a single cabinet of largest size will not accommodate the required number of keys.
Key tags shall consist of two sets: Permanent self-locking and loan key snaphook type with tag colors as follows: Red fiber marker of the permanent self-locking type approximately 32 mm (1-1/4 inch) in diameter engraved with the legend "FILE KEY MUST NOT BE LOANED." Also furnish for each hook a white cloverleaf key marker with snap-hooks engraved with the legend "LOAN KEY."
The manufacturer of the lock cylinders and locks shall attach a key tag to keys of each lock cylinder and shall mark thereon the respective item number and key change number. Provide each group of keys in a key gathering envelope (supplied by Key Cabinet Manufacturer) in which the lock manufacturer shall include the following information: Item number, key change number and door number.
512-23-154
08 71 00-10
The contractor shall furnish the Key Cabinet Manufacturer the hardware and keying schedules and change keys.
The Key Cabinet Manufacturer shall set up a three-way cross index system, including master keys, listing the keys alphabetically, the hooks numerically and the key changes numerically on different colored index cards. Index cards shall be typewritten and inserted in a durable binder. Attach the keys to the two sets of numbered tags supplied with the cabinet. (The permanent tag and the loan key tag).
Instruct the owner in proper use of the system. Install cabinet as directed by the COR.
2.12 ARMOR PLATES, KICK PLATES, MOP PLATES AND DOOR EDGING
Conform to ANSI Standard A156.6.
Provide protective plates as specified below:
1. Kick plates, mop plates and armor plates of metal, Type J100 series.
2. Provide kick plates and mop plates where specified. Kick plates shall be 254 mm (10 inches) or 305 mm (12 inches) high. Mop plates shall be 152 mm (6 inches) high. Both kick and mop plates shall be minimum 1.27 mm (0.050 inches) thick. Provide kick and mop plates beveled on all 4 edges (B4E). On push side of doors where jamb stop extends to floor, make kick plates 38 mm (1-1/2 inches) less than width of door, except pairs of metal doors which shall have plates 25 mm (1 inch) less than width of each door. Extend all other kick and mop plates to within 6 mm (1/4 inch) of each edge of doors. Kick and mop plates shall butt astragals. For jamb stop requirements, see specification sections pertaining to door frames.
3. Kick plates and/or mop plates are not required on following door sides:
a. Armor plate side of doors;
b. Exterior side of exterior doors;
c. Closet side of closet doors;
d. Both sides of aluminum entrance doors.
4. Armor plates for doors are listed under Article "Hardware Sets". Armor plates shall be thickness as noted in the hardware set, 875 mm (35 inches) high and 38 mm (1-1/2 inches) less than width of doors, except on pairs of metal doors. Provide armor plates beveled on all 4 edges (B4E). Plates on pairs of metal doors shall be 25 mm (1 inch) less than width of each door. Where top of intermediate rail of door is less than 875 mm (35 inches) from door bottom, extend armor plates to within 13 mm (1/2 inch) of top of intermediate rail. On doors equipped with panic devices, extend armor plates to within 13 mm (1/2 inch) of panic bolt push bar.
5. Where louver or grille occurs in lower portion of doors, substitute stretcher plate and kick plate in place of armor plate. Size of stretcher plate and kick plate shall be 254 mm (10 inches) high.
6. Provide stainless steel edge guards where so specified at wood doors. Provide mortised type instead of surface type except where door construction and/or ratings will not allow. Provide edge guards of bevel and thickness to match wood door. Provide edge guards with factory cut-outs for door hardware that must be installed through or extend through the edge guard.
512-23-154
08 71 00-11
Provide full-height edge guards except where door rating does not allow; in such cases, provide edge guards to height of bottom of typical lockset armor front. Forward edge guards to wood door manufacturer for factory installation on doors.
2.13 EXIT DEVICES
Conform to ANSI Standard A156.3. Exit devices shall be Grade 1; type and function are specified in hardware sets. Provide flush with finished floor strikes for vertical rod exit devices in interior of building.
Trim shall have cast satin stainless steel lever handles of design similar to locksets, unless otherwise specified. Provide key cylinders for keyed operating trim and, where specified, cylinder dogging.
Surface vertical rod panics shall only be provided less bottom rod; provide fire pins as required by exit device and door fire labels. Do not provide surface vertical rod panics at exterior doors.
Concealed vertical rod panics shall be provided less bottom rod at interior doors, unless lockable or otherwise specified; provide fire pins as required by exit device and door fire labels. Where concealed vertical rod panics are specified at exterior doors, provide with both top and bottom rods.
Where removable mullions are specified at pairs with rim panic devices, provide mullion with key-removable feature.
At non-rated openings with panic hardware, provide panic hardware with key cylinder dogging feature.
Exit devices for fire doors shall comply with Underwriters Laboratories, Inc., requirements for Fire
Exit Hardware. Submit proof of compliance.
2.14 FLUSH BOLTS (LEVER EXTENSION)
Conform to ANSI A156.16. Flush bolts shall be Type L24081 unless otherwise specified. Furnish proper dustproof strikes conforming to ANSI A156.16, for flush bolts required on lower part of doors.
Lever extension manual flush bolts shall only be used at non-fire-rated pairs for rooms only accessed by maintenance personnel.
Face plates for cylindrical strikes shall be rectangular and not less than 25 mm by 63 mm (1 inch by 2-1/2 inches).
Friction-fit cylindrical dustproof strikes with circular face plate may be used only where metal thresholds occur.
Provide extension rods for top bolt where door height exceeds 2184 mm (7 feet 2 inches).
2.15 FLUSH BOLTS (AUTOMATIC)
Conform to ANSI A156.3. Dimension of flush bolts shall conform to ANSI A115. Bolts shall conform to Underwriters Laboratories, Inc., requirements for fire door hardware. Flush bolts shall automatically latch and unlatch. Furnish dustproof strikes conforming to ANSI A156.16 for bottom flushbolt.
Face plates for dustproof strike shall be rectangular and not less than 38 mm by 90 mm (1-1/2 by 3-1/2 inches).
512-23-154
08 71 00-12
At interior doors, provide auto flush bolts less bottom bolt, unless otherwise specified, except at wood pairs with fire-rating greater than 20 minutes; provide fire pins as required by auto flush bolt and door fire labels.
2.16 DOOR PULLS WITH PLATES
Conform to ANSI A156.6. Pull Type J401, 152 mm CTC (6 inches CTC) length by 19 mm (3/4 inches) diameter minimum with plate Type J302, 90 mm by 381 mm (3-1/2 inches by 15 inches), unless otherwise specified. Provide pull with projection of 57.2 mm (2 1/4 inches) minimum and a clearance of
38.1 mm (1 1/2 inches) minimum. Cut plates of door pull plate for cylinders, or turn pieces where required.
2.17 PUSH PLATES
Conform to ANSI A156.6. Metal, Type J302, 203 mm (8 inches) wide by 406.4 mm (16 inches) high. Provide metal Type J302 plates 102 mm (4 inches) wide by 406.4 mm (16 inches) high where push plates are specified for doors with stiles less than 203 mm (8 inches) wide. Cut plates for cylinders, and turn pieces where required.
2.18 COMBINATION PUSH AND PULL PLATES
Conform to ANSI 156.6. Type J303, stainless steel 3 mm (1/8 inch) thick, 80 mm (3-1/3 inches) wide by 800 mm (16 inches) high), top and bottom edges shall be rounded. Secure plates to wood doors with 38 mm (1-1/2 inch) long No. 12 wood screws. Cut plates for turn pieces, and cylinders where required.
Pull shall be mounted down.
2.19 COORDINATORS
Conform to ANSI A156.16. Coordinators, when specified for fire doors, shall comply with
Underwriters Laboratories, Inc., requirements for fire door hardware. Coordinator may be omitted on exterior pairs of doors where either door will close independently regardless of the position of the other door. Coordinator may be omitted on interior pairs of non-labeled open where open back strike is used.
Open back strike shall not be used on labeled doors. Paint coordinators to match door frames, unless coordinators are plated. Provide bar type coordinators, except where gravity coordinators are required at acoustic pairs. For bar type coordinators, provide filler bars for full width and, as required, brackets for push-side surface mounted closers, overhead stops, and vertical rod panic strikes.
2.20 THRESHOLDS
Conform to ANSI A156.21, mill finish extruded aluminum, except as otherwise specified. In existing construction, thresholds shall be installed in a bed of sealant with ¼-20 stainless steel machine screws and expansion shields. In new construction, embed aluminum anchors coated with epoxy in concrete to secure thresholds. Furnish thresholds for the full width of the openings.
For thresholds at elevators entrances see other sections of specifications.
At exterior doors and any interior doors exposed to moisture, provide threshold with non-slip abrasive finish.
Provide with miter returns where threshold extends more than 12 mm (0.5 inch) beyond face of frame.
512-23-154
08 71 00-13
2.21 AUTOMATIC DOOR BOTTOM SEAL AND RUBBER GASKET FOR LIGHT PROOF OR SOUND
CONTROL DOORS
Conform to ANSI A156.22. Provide mortise or under-door type, except where not practical. For mortise automatic door bottoms, provide type specific for door construction (wood or metal).
2.22 WEATHERSTRIPS (FOR EXTERIOR DOORS)
Conform to ANSI A156.22. Air leakage shall not to exceed 0.50 CFM per foot of crack length
(0.000774m3/s/m).
2.23 MISCELLANEOUS HARDWARE
Access Doors (including Sheet Metal, Screen and Woven Wire Mesh Types): Except for fire-rated doors and doors to Temperature Control Cabinets, equip each single or double metal access door with
Lock Type E07213, conforming to ANSI A156.11. Key locks as directed. Ship lock prepaid to the door manufacturer. Hinges shall be provided by door manufacturer.
Cylinders for Various Partitions and Doors: Key cylinders same as entrance doors of area in which partitions and door occur, except as otherwise specified. Provide cylinders to operate locking devices where specified for following partitions and doors:
1. Folding doors and partitions.
2. Wicket door (in roll-up door assemblies).
3. Slide-up doors.
4. Swing-up doors.
5. Fire-rated access doors-Engineer's key set.
6. Doors from corridor to electromagnetic shielded room.
7. Day gate on vault door.
Mutes: Conform to ANSI A156.16. Provide door mutes or door silencers Type L03011 or L03021, depending on frame material, of white or light gray color, on each steel or wood door frame, except at fire-rated frames, lead-lined frames and frames for sound-resistant, lightproof and electromagnetically shielded doors. Furnish 3 mutes for single doors and 2 mutes for each pair of doors, except double-acting doors.
Provide 4 mutes or silencers for frames for each Dutch type door. Provide 2 mutes for each edge of sliding door which would contact door frame.
2.24 PADLOCKS FOR VARIOUS DOORS, GATES AND HATCHES
ASTM E883, size 50 mm (2 inch) wide chain; furnish extended shackles as required by job conditions. Provide padlocks, with key cylinders, for each door in following areas as noted.
Key padlocks as follows:
1. Roof Access and Scuttles: Engineer's set.
512-23-154
08 71 00-14
2.25
2.26 FINISHES
Exposed surfaces of hardware shall have ANSI A156.18, finishes as specified below. Finishes on all hinges, pivots, closers, thresholds, etc., shall be as specified below under "Miscellaneous Finishes." For field painting (final coat) of ferrous hardware, see Section 09 91 00, PAINTING.
626 or 630: All surfaces on exterior and interior of buildings, except where other finishes are specified.
Miscellaneous Finishes:
1. Hinges --exterior doors: 626 or 630.
2. Hinges --interior doors: 652 or 630.
3. Pivots: Match door trim.
4. Door Closers: Factory applied paint finish. Dull or Satin Aluminum color.
5. Thresholds: Mill finish aluminum.
6. Cover plates for floor hinges and pivots: 630.
7. Other primed steel hardware: 600.
Special Finish: Exposed surfaces of hardware for dark bronze anodized aluminum doors shall have oxidized oil rubbed bronze finish (dark bronze) finish on door closers shall closely match doors.
2.27 BASE METALS
Apply specified U.S. Standard finishes on different base metals as following:
Finish Base Metal
652 Steel
626 Brass or bronze
630 Stainless steel
PART 3 - EXECUTION
3.1 HARDWARE HEIGHTS
For new buildings locate hardware on doors at heights specified below, with all hand-operated hardware centered within 864 mm (34 inches) to 1200 mm (48 inches), unless otherwise noted:
Hardware Heights from Finished Floor:
1. Exit devices centerline of strike (where applicable) 1024 mm (40-5/16 inches).
2. Locksets and latch sets centerline of strike 1024 mm (40-5/16 inches).
3. Deadlocks centerline of strike 1219 mm (48 inches).
4. Hospital arm pull 1168 mm (46 inches) to centerline of bottom supporting bracket.
5. Centerline of door pulls to be 1016 mm (40 inches).
6. Push plates and push-pull shall be 1270 mm (50 inches) to top of plate.
7. Push-pull latch to be 1024 mm (40-5/16 inches) to centerline of strike.
512-23-154
08 71 00-15
8. Locate other hardware at standard commercial heights. Locate push and pull plates to prevent conflict with other hardware.
3.2 INSTALLATION
Closer devices, including those with hold-open features, shall be equipped and mounted to provide maximum door opening permitted by building construction or equipment. Closers shall be mounted on side of door inside rooms, inside stairs, and away from corridors. At exterior doors, closers shall be mounted on interior side. Where closers are mounted on doors they shall be mounted with hex nuts and bolts; foot shall be fastened to frame with machine screws. Door opening force shall not exceed 22.2 N (5 pounds) maximum in accordance with ABAAS. Measure and adjust opening force for all doors equipped with closers.
Hinge Size Requirements:
Door Thickness Door Width Hinge Height
45 mm (1-3/4 inch) 900 mm (3 feet) and less 113 mm (4-1/2 inches)
45 mm (1-3/4 inch) Over 900 mm (3 feet) but not more than 1200 mm (4 feet)
125 mm (5 inches)
35 mm (1-3/8 inch) (hollow core wood doors)
Not over 1200 mm (4 feet) 113 mm (4-1/2 inches)
Hinge leaves shall be sufficiently wide to allow doors to swing clear of door frame trim and surrounding conditions.
Hinges Required Per Door:
Door Description Number butts
Doors 1500 mm (5 ft) or less in height 2 butts
Doors over 1500 mm (5 ft) high and not over 2280 mm (7 ft 6 in) high 3 butts
Doors over 2280 mm (7 feet 6 inches) high 4 butts
Dutch type doors 4 butts
Doors with spring hinges 1370 mm (4 feet 6 inches) high or less 2 butts
Doors with spring hinges over 1370 mm (4 feet 6 inches) 3 butts
Fastenings: Suitable size and type and shall harmonize with hardware as to material and finish.
Provide machine screws and lead expansion shields to secure hardware to concrete, ceramic or quarry floor tile, or solid masonry. Fiber or rawl plugs and adhesives are not permitted. All fastenings exposed to weather shall be of nonferrous metal.
After locks have been installed; show in presence of COR that keys operate their respective locks in accordance with keying requirements. (All keys, Master Key level and above shall be sent Registered
Mail to the Medical Center Director along with the bitting list. Also a copy of the invoice shall be sent to the
512-23-154
08 71 00-16
COR for his records.) Installation of locks which do not meet specified keying requirements shall be considered sufficient justification for rejection and replacement of all locks installed on project.
3.3 FINAL INSPECTION
Installer to provide letter to VA Resident/Project Engineer that upon completion, installer has visited the Project and has accomplished the following:
1. Re-adjust hardware.
2. Evaluate maintenance procedures and recommend changes or additions, and instruct VA personnel.
3. Identify items that have deteriorated or failed.
4. Submit written report identifying problems.
3.4 DEMONSTRATION
Demonstrate efficacy of mechanical hardware and electrical, and electronic hardware systems, including adjustment and maintenance procedures, to satisfaction of Resident/Project Engineer and VA
Locksmith.
3.5 HARDWARE SETS
Following sets of hardware correspond to hardware symbols shown on drawings. Only those hardware sets that are shown on drawings will be required. Disregard hardware sets listed in specifications but not shown on drawings.
Hardware Consultant working on a project will be responsible for providing additional information regarding these hardware sets. The numbers shown in the following sets come from BHMA standards.
ELECTRIC HARDWARE ABBREVIATIONS LEGEND:
ADO = Automatic Door Operator
EMCH = Electro-Mechanical Closer-Holder
MHO = Magnetic Hold-Open (wall- or floor-mounted)
The hardware sets represent the design intent and direction of the owner and architect.
Discrepancies, conflicting hardware and missing items should be brought to the attention of the architect with corrections made prior to the bidding process. Omitted items not included in a hardware set should be scheduled with the appropriate additional hardware required for proper application and functionality.
1) Quantities listed are for each pair of doors, or for each single door.
2) The supplier is responsible for handing and sizing all products.
3) Where multiple options for a piece of hardware are given in a single line item, the supplier shall provide the appropriate application for the opening.
4) At existing openings with new hardware the supplier shall field inspect existing conditions prior to the submittal stage to verify the specified hardware will work as required. Provide alternate solutions and proposals as needed.
Manufacturer’s Abbreviations:
1. MK - McKinney
512-23-154
08 71 00-17
2. SU - Securitron
3. RO - Rockwood
4. SA - SARGENT
5. RU - Corbin Russwin
6. YA - ASSA ABLOY ACCENTRA
7. RF - Rixson
8. NO - Norton
9. PE - Pemko
Sets:
Hardware Sets
Set: 1.0
Doors: 101, 107B, 113A
Description: EXT - PR - PANIC NL
2 Continuous Hinge CFM83HD US32D PE
1 Mullion L980S PC SA
1 Rim Exit Device, Dummy BAA 72 8810 ETP US32D SA
1 Rim Exit Device, Storeroom BAA 72 8804 ETP US32D SA
1 Cylinder [Mullion] 980C1 US26D SA
2 Surface Closer/Stop 351 CPS EN SA
2 Armor Plate K1050 36" X 1" LDW CSK TEK US32D RO
2 Door Stop 463-RKW US32D RO
1 Astragal S772D [ mtg on mull ] PE
1 Gasketing S88BL PE
1 Rain Guard 346C x LAR PE
2 Sweep 3452APK TKSP PE
1 Threshold 2005AT MSES25SS PE
2 Position Switch DPS-M/W -W As Required SU
Notes: *Waiver may be required to comply with Buy American Act. Compliancy of this product to current
Buy American-type regulations must be validated with the manufacturer.
Set: 2.0 https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=134315680,153428482,134325262, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=134315680,153428482,134325262, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211970545, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211869230,211868604,211868307, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211869230,211868604,211868304, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211928231, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211928300, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212002982, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168873931, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168875935, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168874097, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168874125, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168874286, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211955486, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211975386,211975349, 512-23-154
08 71 00-18
Doors: 102A, 102C, 102D
Description: EXT - PANIC NL
1 Continuous Hinge CFM83HD US32D PE
1 Rim Exit Device, Storeroom BAA 72 8804 ETP US32D SA
1 Surface Closer/Stop 351 CPS EN SA
1 Armor Plate K1050 36" X 1.5" LDW CSK TEK US32D RO
1 Door Stop 463-RKW US32D RO
1 Gasketing S88BL PE
1 Rain Guard 346C x LAR PE
1 Sweep 3452APK TKSP PE
Notes: *Waiver may be required to comply with Buy American Act. Compliancy of this product to current
Set: 3.0
Doors: 104B, 105, 106A
Description: EXT - LK
1 Continuous Hinge CFM83HD US32D PE
1 Dormitory/Exit Lock BAA 72 8225 LNP US32D SA
1 Surface Closer/Stop 351 CPS EN SA
1 Armor Plate K1050 36" X 1.5" LDW CSK TEK US32D RO
1 Door Stop 463-RKW US32D RO
1 Gasketing S88BL PE
1 Rain Guard 346C x LAR PE
1 Sweep 3452APK TKSP PE
Notes: *Waiver may be required to comply with Buy American Act. Compliancy of this product to current
Set: 4.0
Doors: 107A, 108
Description: RATED - ELECT https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=153428482,134325262, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=134315680,153428482,134325262, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=134315680,153428482,134325262, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211869230,211868604,211868304, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211928300, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212002982, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168873931, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168874097, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168874125, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168874286, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211955486, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=134315680,153428482,134325262, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=134315680,153428482,134325262, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=134315680,153428482,134325262, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212001598,211870340,211871341, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211928300, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212002982, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168873931, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168874097, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168874125, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168874286, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211955486, 512-23-154
08 71 00-19
3 Hinge T4A3786 x USA US26D MK
1 Rim Exit Device, Storeroom BAA 12 72 8804 ETP US32D SA
1 Surface Closer/Stop 351 CPS EN SA
2 Armor Plate K1050 36" X 1.5" LDW CSK TEK US32D RO
1 Door Stop 409 / 446 [as required] US26D RO
1 Gasketing S88BL PE
Notes: *Waiver may be required to comply with Buy American Act. Compliancy of this product to current
Set: 5.0
Doors: 104
Description: RATED - OFFICE - OHS
3 Hinge T4A3786 x USA US26D MK
1 Office/Entry Lock BAA 72 8255 LNP US26D SA
1 Surface Closer/Stop 351 CPS EN SA
2 Armor Plate K1050 36" X 1.5" LDW CSK TEK US32D RO
Notes: *Waiver may be required to comply with Buy American Act. Compliancy of this product to current
Set: 6.0
Doors: 103, 106B
Description: STOR - OHS
1 Storeroom/Closet Lock BAA 72 8204 LNP US26D SA
1 Surf Overhead Stop 9-X36 689 RF
3 Silencer 608 RO
Notes: *Waiver may be required to comply with Buy American Act. Compliancy of this product to current
Set: 7.0 https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211959684, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211869230,211868604,211868304, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211928300, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212002982, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168873928, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168874097, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=153428482,134325262, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211959684, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212001598,211870340,211871327, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211928300, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212002982, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168874097, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=153428482,134325262, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=134315680,153428482,134325262, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211959684, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212001598,211870340,211871321, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=70787782, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212002982, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212005379, 512-23-154
08 71 00-20
Doors: 110, 111
Description: TOILET - OHS
1 Privacy Lock BAA LB V21 8265 LNP US26D SA
1 Surface Closer/Stop 351 CPS EN SA
Notes: *Waiver may be required to comply with Buy American Act. Compliancy of this product to current
Set: 8.0
Doors: 109, 112
Description: RESTROOM - OHS
1 Pull Plate BF 110 x 70C US32D RO
1 Push Plate 71E [6 X 16] US32D RO
1 Surface Closer/Stop 351 CPS EN SA
2 Armor Plate K1050 36" X 1.5" LDW CSK TEK US32D RO
1 Door Stop 409 / 446 [as required] US26D RO
Notes: *Waiver may be required to comply with Buy American Act. Compliancy of this product to current
Set: 9.0
Doors: 102B
Description: OH DOOR
1 HBO-Balance Balance of hardware by door mfg
Notes: *Waiver may be required to comply with Buy American Act. Compliancy of this product to current https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211959684, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212001598,211870340,211871330, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211928300, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212002982, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168874097, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=153428482,134325262, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=153428482,134325262, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211959684, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168873893, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212029135,168873833, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=211928300, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=212002982, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168873928, https://www.openingsstudio.com/AAOS/AAOS/CutSheetViewer.jsp?IDS=168874097, 512-23-154
08 71 00-21
- - - E N D - - -