087100 Door Hardware.pdf
PDF 129 KB Posted
- Attached to
- Y1LZ--693-222 | Parking Structure Solicitation Amendment 2 Federal contract opportunity
- Solicitation number
- 36C24420R0075
About this file
This solicitation is for the construction of a new parking structure at the Wilkes-Barre VA Medical Center campus. The project scope includes providing all labor, materials, equipment, permits, testing and reports to construct a parking garage accommodating approximately 435 vehicles, according to the drawings and specifications. The magnitude of the project is estimated between $10-20 million. Offerors must comply with all applicable federal, state and local codes and VA rules. The contractor will be responsible for proper worker classification and wage compliance. Pricing must be in whole dollars. This set-aside procurement utilizes a tiered evaluation process down to the large business tier for SDVOSBs. The solicitation may be canceled before award if in the government's best interest.
View the file
Other files for this federal contract opportunity
Show all 50
Y1LZ--693-222 | Parking Structure Solicitation Amendment 2 has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Parking Garage Project Number 693-222 Department of Veterans Affairs Wilkes-Barre, Pennsylvania
SECTION 087100 DOOR HARDWARE
PART 1 - GENERAL
1.1 SUMMARY:
A. Section Includes: Finish Hardware for door openings, except as otherwise specified herein.
1. Door hardware for steel (hollow metal) doors.
2. Door hardware for aluminum doors.
3. Door hardware for other doors indicated.
4. Keyed cylinders as indicated.
B. Related Sections:
1. Division 6: Rough Carpentry.
2. Division 8: Aluminum Doors and Frames
3. Division 8: Hollow Metal Doors and Frames.
4. Division 26 Electrical
5. Division 28: Electronic Security
C. References: Comply with applicable requirements of the following standards. Where these standards conflict with other specific requirements, the most restrictive shall govern.
1. Builders Hardware Manufacturing Association (BHMA)
2. NFPA 101 Life Safety Code
3. NFPA 80 -Fire Doors and Windows
4. ANSI-A156.xx- Various Performance Standards for Finish Hardware
5. UL10C – Positive Pressure Fire Test of Door Assemblies
6. ANSI-A117.1 – Accessible and Usable Buildings and Facilities
7. DHI /ANSI A115.IG – Installation Guide for Doors and Hardware
8. ICC – International Building Code
D. Intent of Hardware Groups
1. Should items of hardware not definitely specified be required for completion of the Work, furnish such items of type and quality comparable to adjacent hardware and appropriate for service required.
2. Where items of hardware aren’t definitely or correctly specified, are required for completion of the Work, a written statement of such omission, error, or other discrepancy to be submitted to Architect, prior to date specified for receipt of bids for clarification by addendum; or, furnish such items in the type and quality established by this specification, and appropriate to the service intended.
E. Alternates
1. Refer to Division 1 for Alternates and procedures.
Wilkes-Barre, Pennsylvania
1.2 SUBSTITUTIONS:
A. Comply with Division 1.
1.3 SUBMITTALS:
A. Comply with Division 1.
B. Special Submittal Requirements: Combine submittals of this Section with Sections listed below to ensure the "design intent" of the system/assembly is understood and can be reviewed together.
C. Product Data: Manufacturer's specifications and technical data including the following:
1. Detailed specification of construction and fabrication.
2. Manufacturer's installation instructions.
3. Wiring diagrams for each electric product specified. Coordinate voltage with electrical before submitting.
4. Submit 6 copies of catalog cuts with hardware schedule.
5. Provide 9001-Quality Management and 14001-Environmental Management for products listed in
Materials Section 2.2
D. Shop Drawings - Hardware Schedule: Submit 6 complete reproducible copy of detailed hardware schedule in a vertical format.
1. List groups and suffixes in proper sequence.
2. Completely describe door and list architectural door number.
3. Manufacturer, product name, and catalog number.
4. Function, type, and style.
5. Size and finish of each item.
6. Mounting heights.
7. Explanation of abbreviations and symbols used within schedule.
8. Detailed wiring diagrams, specially developed for each opening, indicating all electric hardware, security equipment and access control equipment, and door and frame rough-ins required for specific opening.
E. Templates: Submit templates and "reviewed Hardware Schedule" to door and frame supplier and others as applicable to enable proper and accurate sizing and locations of cutouts and reinforcing.
1. Templates, wiring diagrams and "reviewed Hardware Schedule" of electrical terms to electrical for coordination and verification of voltages and locations.
F. Samples: (If requested by the Architect)
1. 1 sample of Lever and Rose/Escutcheon design, (pair).
2. 3 samples of metal finishes
G. Contract Closeout Submittals: Comply with Division 1 including specific requirements indicated.
1. Operating and maintenance manuals: Submit 3 sets containing the following.
Wilkes-Barre, Pennsylvania
a. Complete information in care, maintenance, and adjustment, and data on repair and replacement parts, and information on preservation of finishes.
b. Catalog pages for each product.
c. Name, address, and phone number of local representatives for each manufacturer.
d. Parts list for each product.
2. Copy of final hardware schedule, edited to reflect, "As installed".
3. Copy of final keying schedule
4. As installed “Wiring Diagrams” for each piece of hardware connected to power, both low voltage and 110 volts.
5. One set of special tools required for maintenance and adjustment of hardware, including changing of cylinders.
1.4 QUALITY ASSURANCE
A. Comply with Division 1.
1. Statement of qualification for distributor and installers.
2. Statement of compliance with regulatory requirements and single source responsibility.
3. Distributor's Qualifications: Firm with 3 years’ experience in the distribution of commercial hardware.
a. Distributor to employ full time Architectural Hardware Consultants (AHC) for the purpose of scheduling and coordinating hardware and establishing keying schedule.
b. Hardware Schedule shall be prepared and signed by an AHC.
4. Installer's Qualifications: Firm with 3 years experienced in installation of similar hardware to that required for this Project, including specific requirements indicated.
5. Regulatory Label Requirements: Provide testing agency label or stamp on hardware for labeled openings.
a. Provide UL listed hardware for labeled and 20-minute openings in conformance with requirements for class of opening scheduled.
b. Underwriters Laboratories requirements have precedence over this specification where conflict exists.
6. Single Source Responsibility: Except where specified in hardware schedule, furnish products of only one manufacturer for each type of hardware.
B. Review Project for extent of finish hardware required to complete the Work. Where there is a conflict between these Specifications and the existing hardware, notify the Architect in writing and furnish hardware in compliance with the Specification unless otherwise directed in writing by the Architect.
Furnish custom strikes, door wrap-arounds as needed. Existing frames and doors may need modification for new hardware as specified. Call out any discrepancies to the architect when submitting shop drawings for approval or before submission.
1.5 DELIVERY, STORAGE, AND HANDLING
A. Packing and Shipping: Comply with Division 1.
Wilkes-Barre, Pennsylvania
1. Deliver products in original unopened packaging with legible manufacturer's identification.
2. Package hardware to prevent damage during transit and storage.
3. Mark hardware to correspond with "reviewed hardware schedule".
4. Deliver hardware to door and frame manufacturer upon request.
B. Storage and Protection: Comply with manufacturer's recommendations.
1.6 PROJECT CONDITIONS:
A. Coordinate hardware with other work. Furnish hardware items of proper design for use on doors and frames of the thickness, profile, swing, security and similar requirements indicated, as necessary for the proper installation and function, regardless of omissions or conflicts in the information on the Contract Documents.
B. Review Shop Drawings for doors and entrances to confirm that adequate provisions will be made for the proper installation of hardware.
1.7 WARRANTY:
A. Refer to Conditions of the Contract
B. Manufacturer’s Warranty:
1. Closers: Thirty years
2. Exit Devices: Five Years
3. Locksets: Limited Lifetime
4. All other Hardware: Two years.
1.8 OWNER’S INSTRUCTION:
A. Instruct Owner’s personnel in operation and maintenance of hardware units.
1.9 MAINTENANCE:
A. Extra Service Materials: Deliver to Owner extra materials from same production run as products installed. Package products with protective covering and identify with descriptive labels. Comply with Division 1 Closeout Submittals Section.
1. Special Tools: Provide special wrenches and tools applicable to each different or special hardware component.
2. Maintenance Tools: Provide maintenance tools and accessories supplied by hardware component manufacturer.
3. Delivery, Storage and Protection: Comply with Owner’s requirements for delivery, storage and protection of extra service materials.
B. Maintenance Service: Submit for Owner’s consideration maintenance service agreement for electronic products installed.
Wilkes-Barre, Pennsylvania
PART 2 - PRODUCTS
2.1 MANUFACTURERS:
A. The following manufacturers are approved subject to compliance with requirements of the Contract Documents. Approval of manufacturers other than those listed shall be in accordance with Division 1.
Item: Manufacturer: Approved:
Hinges Stanley Bommer, McKinney Continuous Hinges Stanley Select, ABH Locksets Yale (No substitute - match the VAMC Master System) Cylinders Yale (No substitute - match the VAMC Master System) Exit Devices Precision Von Duprin 98-32D, Sargent 19-GL-80 Series Closers Stanley D-4550 Dorma 8900, Norton 7500 Push/Pull Plates Trimco Burns, Rockwood Push/Pull Bars Trimco Burns, Rockwood Protection Plates Trimco Burns, Rockwood Overhead Stops Dorma ABH, Glynn Johnson Door Stops Trimco Burns, Rockwood Flush Bolts Trimco ABH, Burns Coordinator & Brackets Trimco ABH, Burns Threshold & Gasketing National Guard Reese, K.N. Crowder
2.2 MATERIALS:
A. Hinges:
1. Template screw hole locations
2. Minimum of 2 permanently lubricated non-detachable bearings
3. Equip with easily seated, non-rising pins
4. Sufficient size to allow 180-degree swing of door
5. Furnish hinges with five knuckles and flush [concealed] bearings
6. Provide hinge type as listed in schedule.
7. Furnish 3 hinges per leaf to 7-foot 6-inch height. Add one for each additional 30 inches in height or fraction thereof.
8. Tested and approved by BHMA for all applicable ANSI Standards for type, size, function and finish
9. UL10C listed for Fire rated doors.
B. Geared Continuous Hinges:
1. Tested and approved by BHMA for ANSI A156.26-1996 Grade 1
2. Anti-spinning through fastener
3. UL10C listed for 3-hour Fire rating
4. Non-handed
5. Lifetime warranty
6. Provide Fire Pins for 1 ½ -hour fire ratings
7. Sufficient size to permit door to swing 180 degrees
Wilkes-Barre, Pennsylvania
C. Mortise Type Locks and Latches:
1. Tested and approved by BHMA for ANSI A156.13, Series 1000, Operational Grade 1, Extra-Heavy Duty, Security Grade 2 and be UL10C.
2. Furnish UL or recognized independent laboratory certified mechanical operational testing to 4 million cycles minimum.
3. Provide 9001-Quality Management and 14001-Environmental Management.
4. Fit ANSI A115.1 door preparation
5. Functions and design as indicated in the hardware groups
6. Solid, one-piece, 3/4-inch (19mm) throw, anti-friction latchbolt made of self-lubricating stainless steel
7. Deadbolt functions shall have 1 inch (25mm) throw bolt made of hardened stainless steel
8. Latchbolt and Deadbolt are to extend into the case a minimum of 3/8 inch (9.5mm) when fully extended
9. Auxiliary deadlatch to be made of one-piece stainless steel, permanently lubricated
10. Provide sufficient curved strike lip to protect door trim
11. Lever handles must be of forged or cast brass, bronze or stainless-steel construction and conform to ANSI A117.1. Levers that contain a hollow cavity are not acceptable
12. Lock shall have self-aligning, thru-bolted trim
13. Levers to operate a roller bearing spindle hub mechanism
14. Mortise cylinders of lock shall have a concealed internal setscrew for securing the cylinder to the lockset. The internal setscrew will be accessible only by removing the core, with the control key, from the cylinder body.
15. Spindle to be designed to prevent forced entry from attacking of lever
16. Provide locksets with 7-pin removable and interchangeable core cylinders
17. Each lever to have independent spring mechanism controlling it
18. Core face must be the same finish as the lockset.
D. Mortise Deadbolt:
1. Tested and approved by ANSI A156.36, Operational Grade 1.
2. Provide 9001-Quality Management and 14001-Environmental Management.
3. Locksets and cores to be of the same manufacturer to maintain complete lockset warranty
4. 2-3/4-inch (70mm) backset
5. 1-inch throw deadbolt
6. Provide locksets with 7-pin core.
E. Exit Devices shall:
1. Tested and approved by BHMA for ANSI 156.3, Grade 1
2. Provide 9001-Quality Management and 14001-Environmental Management.
3. Furnish UL or recognized independent laboratory certified mechanical operational testing to 10 million cycles minimum.
4. Provide a deadlocking latchbolt
5. Non-fire rated exit devices shall have cylinder dogging.
6. Touchpad shall be “T” style
7. Exposed components shall be of architectural metals and finishes.
8. Lever design shall match lockset lever design
Wilkes-Barre, Pennsylvania
9. Provide strikes as required by application.
10. Fire exit devices to be listed for UL10C
11. UL listed for Accident Hazard
12. Shall consist of a cross bar or push pad, the actuating portion of which extends across, shall not be less than one half the width of the door leaf.
13. Provide vandal resistant or breakaway trim
14. Aluminum vertical rod assemblies are acceptable only when provide with the manufacturers optional top and bottom stainless steel rod guard protectors.
F. Cylinders:
1. Provide the necessary cylinder housings, collars, rings & springs as recommended by the manufacturer for proper installation.
2. Provide the proper cylinder cams or tail piece as required to operate all locksets and other keyed hardware items listed in the hardware sets.
3. Coordinate and provide as required for related sections.
G. Door Closers shall:
1. Tested and approved by BHMA for ANSI 156.4, Grade 1
2. UL10C certified
3. Provide 9001-Quality Management and 14001-Environmental Management.
4. Closer shall have extra-duty arms and knuckles
5. Conform to ANSI 117.1
6. Maximum 2 7/16-inch case projection with non-ferrous cover
7. Separate adjusting valves for closing and latching speed, and backcheck
8. Provide adapter plates, shim spacers and blade stop spacers as required by frame and door conditions
9. Full rack and pinion type closer with 1½“ minimum bore
10. Mount closers on non-public side of door, unless otherwise noted in specification
11. Closers shall be non-handed, non-sized and multi-sized.
H. Door Stops: Provide a dome floor or wall stop for every opening as listed in the hardware sets.
1. Wall stop and floor stop shall be wrought bronze, brass or stainless steel.
2. Provide fastener suitable for wall construction.
3. Coordinate reinforcement of walls where wall stop is specified.
4. Provide dome stops where wall stops are not practical. Provide spacers or carpet riser for floor conditions encountered
I. Over Head Stops: Provide a Surface mounted or concealed overhead when a floor or wall stop cannot be used or when listed in the hardware set.
1. Concealed overhead stops shall be heavy duty bronze or stainless steel.
2. Surface overhead stops shall be heavy duty bronze or stainless steel.
J. Push Plates: Provide with four beveled edges ANSI J301, .050 thickness, size as indicated in hardware set. Furnish oval-head countersunk screws to match finish.
Wilkes-Barre, Pennsylvania
K. Pulls with plates: Provide with four beveled edges ANSI J301, .050 thickness Plate s with ANSI J401 Pull as listed in hardware set. Provide proper fasteners for door construction.
L. Kickplates: Provide with four beveled edges ANSI J102, 10 inches high by width less 2 inches on single doors and 1 inch on pairs of doors. Furnish oval-head countersunk screws to match finish.
M. Armor Plates: Provide ANSI J101 with four beveled edges, 40 inches high by width less 1 inch on single or pairs of doors. Furnish oval-head countersunk screws to match finish.
1. Provide cutouts for hardware as listed in the hardware sets.
2. Provide Warnock Hersey labeled plates for 3-hour metal fire doors where allowed by local authority.
N. Door Bolts: Flush bolts for wood or metal doors.
1. Provide a set of Automatic bolts, Certified ANSI/BHMA 156.3 Type 25 for hollow metal label doors.
2. Provide a set of Automatic bolts, Certified ANSI/BHMA 156.3 Type 27 at wood label doors.
3. Manual flush bolts, Certified ANSI/BHMA 156.16 at openings where allowed local authority.
4. Provide Dust Proof Strike, Certified ANSI/BHMA 156.16 at doors with flush bolts without thresholds.
O. Coordinator and Brackets: Provide a surface mounted coordinator when automatic bolts are used in the hardware set.
1. Coordinator, Certified ANSI/BHMA A1156.3 Type 21A for full width of the opening.
2. Provide mounting brackets for soffit applied hardware.
3. Provide hardware preparation (cutouts) for latches as necessary.
P. Quick Connect Power Transfer: Power transfer device shall be a steel housing and flexible tube. Secure and inconspicuous channel is to bring power from the frame to the door.
1. Precision EPT-12C
2. Tube shall contain 12 Wire bundle with Stanley Quick Connect Connectors one 4 wire connector consisting of two 18AWG wires and 2 24AWG wires and one 8 wire connector with 8 24AWG wires.
Q. Surface mounted Door Loop Power Transfer: Armored flex conduit is to bring power from the frame to the door. The tube shall accept up to 1/4” wire bundle and is 18” long.
1. Precision EPT-2
2. Wires as required by others.
R. Power Supply: Provide power supply PS873 series for Electric Latch Retraction exit devices. Provide the appropriate control circuit card necessary to operate the number of EL exit devices used at each opening.
Example PS873X2
1. UL Listed for class II output
2. Include circuit breakers for protection of motherboard
3. 120 Volt AC input at 1 Amp
4. Control module shall include Fire alarm terminal contacts.
Wilkes-Barre, Pennsylvania
S. Power Transfer: Power transfer device shall be a steel housing and flexible tube. Secure and inconspicuous channel is to bring power from the frame to the door.
1. Von Duprin EPT Series
2. EPT-2, two 18 Ga. wires
3. EPT-10 ten 24 Ga. wires
T. Electromagnetic Locks: Certified by BHMA for A156.23; electrically powered, of strength and configuration indicated; with electromagnet attached to frame and armature plate attached to door
1. Type: Full exterior or full interior, as required by application indicated.
2. Strength Ranking: 500 lbf
3. Inductive Kickback Peak Voltage: Not more than 0 V.
4. Residual Magnetism: Not more than 25 lbf to separate door from magnet.
U. Power Supply: UL Listed, Field Selectable 12VDC or 24VDC output. The power supply will specifically be designed to support electric locks and access controls. The power supply uses 115 VACS at 800mA input.
The power shall be able to be expanded to four station controls. The filtered and regulated output power is field selectable for 12 or 24 VDC.
1. Fire Alarm/Life Safety emergency release included in power supply.
2. Available options for multiple door options four or more control stations, Adjustable Time delay relay, Battery charging, Battery Backup.
V. Electric Door Strike: Certified by ANSI/BHMA 156.31, Grade 1. and listed for Burglary Protection ANSI/ UL1034 Grade 1.
1. For General use provide fail-secure electric strike and with fire-rated device.
2. Listed UL10C for Fire Door assemblies
3. Latchbolt monitor switch option when specified in hardware sets.
4. Provide the electric strike in the appropriate model that will accept a 5/8” or 3/4" latchbolt.
W. Door Position Switch: Provide door position switch for door status monitoring as indicated in hardware sets.
1. At all fired rated doors the door and frames, position switch preparation will be provided by the door and frame manufacturer or by an authorized label service agent.
X. Quick Connect plug-in connectors: Stanley quick connect plug-in must be used with a combination of the following components to work as a complete plug and play system.
1. Best locks series 45HW, 45HM, 8KW, 9KW, 9KM
2. To include Quick connectors to Best lock products Suffix “C” Example (45HW-7DEL14H DS C)
3. Precision Exit Devices 2000 Series, DE, DS, TS, TDS, LDS, ELR
4. To include Quick connectors to Precision Electric Exit Device products Prefix “C” Example (C ELR
2108 x V4908A TS)
5. Precision 12 Conductor Electric Power Transfer EPT-12C
6. Stanley 12 Hinges Conductor Hinge CECB179-12C
Y. Quick Connect Wire Harnesses: The Quick Connect wire harness shall have of one four wire connector and one eight wire connector. The four-wire connector has two 18AWG and two 24AWG wires. The
Wilkes-Barre, Pennsylvania eight-wire connector has eight 24AWG wires Stanley quick connect wire harnesses are available in various length’s, 3” (76mm), 6” (152mm), 12” (304mm), 26” (660mm) 32” (812mm) 38” (965mm), 44” (1117mm), 50” (1270mm) and 192” (4876mm).
1. Wire Harness that is terminated at both ends is specified as WH-size (Example WH-3).
2. Wire Harness that is terminated at one end with exposed pin head at the other is specified as WH-size P (Example WH-3P).
3. Wire Harness 6” (152mm) terminated at one end with bray leads on the other is specified as WH-
6E.
Notes the Wire harnesses with suffix “E” has brae wire ends, is used to connect the quick connect harness to a hardwired connection.
Wire harnesses of different lengths may be combined to form a desired length The maximum size hole needed to pass through the quick connect plug is 1” (25MM).
Z. Magnetic Door Holders: Provide magnetic door holders with Tri-Voltage that can be wired 12VDC, 24V AC/DC or 120V AC
1. Wall magnetic door holders shall be Recessed.
2. Armature shall be thru-bolted and can be provided with any projection required.
3. Models will be available in US28, sprayed finishes and US32D.
4 Floor mounted shall be provided for a single door or double door hold open application.
AA. Seals: All seals shall be finished to match adjacent frame color. Seals shall be furnished as listed in schedule. Material shall be UL listed for labeled openings.
BB. Weatherstripping: Provide at head and jambs only those units where resilient or flexible seal strip is easily replaceable. Where bar-type weatherstrip is used with parallel arm mounted closers install weatherstrip first.
1. Weatherstrip shall be resilient seal of (Neoprene, Polyurethane, Vinyl, Pile, Nylon Brush, Silicone)
2. UL10C Positive Pressure rated seal set when required.
CC. Door Bottoms/Sweeps: Surface mounted or concealed door bottom where listed in the hardware sets.
1. Door seal shall be resilient seal of (Neoprene, Polyurethane, Nylon Brush, Silicone)
2. UL10C Positive Pressure rated seal set when required.
DD. Thresholds: Thresholds shall be aluminum beveled type with maximum height of ½” for conformance with ADA requirements. Furnish as specified and per details. Provide fasteners and screws suitable for floor conditions.
EE. Provide one wall mounted Telkee, Lund or MMF series key cabinet complete with hooks, index and tags to accommodate 50% expansion. Coordinate mounting location with architect.
FF. Keystone Web Key Management Software: Provide one, Keystone Web product “KSWN” key management software. Shall include
1. Configurable Password Policy for logins.
2. User friendly interface - Tile Icons and Customizable dashboard.
Wilkes-Barre, Pennsylvania
3. Easy Data Entry & Import to import/append data continuously.
4. Active Directory synchronization to reduce manual entry.
5. Configurable Email notifications for all keys and other items currently due back on a designated day, notifications when keys and items are issued, and notifications when keys and other items are returned.
6. Global Search functionality capable of listing all cores and their location, building and doors.
7. Cross-references people to cores and keys, doors, and buildings they access.
8. Customizable Reports.
9. Self-serve Password retrieval functionality.
10. Program shall be standalone or network capable, LAN or WAN compatible.
11. Flexibility: The software shall be capable of allowing an authorized user secure access to the software from anywhere, provided user can access their organization’s secure network.
12. Encrypted database and SQL server express backend.
13. Software program is to be compatible with Windows 7 Professional 32/64 bit (Standalone PC).
Windows 2008/2012 Server 32/64 bit.
14. Browser Requirements: Internet Explorer 10 or greater Microsoft Edge browser latest Firefox or
Chrome Internet browsers.
15. Minimum Microsoft software Prerequisites: SQL Server 2014 Express or Greater. NET Framework
4.5 or greater.
GG. Silencers: Furnish silencers on all interior frames, 3 for single doors, 2 for pairs. Omit where any type of seals occur.
2.3 FINISH:
A. Designations used in Schedule of Finish Hardware - 3.05, and elsewhere to indicate hardware finishes are those listed in ANSI/BHMA A156.18 including coordination with traditional U.S. finishes shown by certain manufacturers for their products
B. Powder coat door closers to match other hardware, unless otherwise noted.
C. Aluminum items shall be finished to match predominant adjacent material. Seals to coordinate with frame color.
2.4 KEYS AND KEYING:
A. Provide keyed brass construction cores and keys during the construction period. Construction control and operating keys and core shall not be part of the Owner's permanent keying system or furnished in the same keyway (or key section) as the Owner's permanent keying system. Permanent cores and keys (prepared according to the accepted keying schedule) will be furnished to the Owner.
B. Cylinders, removable and interchangeable core system. Yale Locksets matching the existing VAMC system is the only locksets to be provided.
C. Permanent keys and cores: Stamped with the applicable key mark for identification. These visual key control marks or codes will not include the actual key cuts. Permanent keys will also be stamped "Do Not Duplicate."
Wilkes-Barre, Pennsylvania
D. Transmit Grand Masterkeys, Masterkeys and other Security keys to Owner by Registered Mail, return receipt requested.
E. Furnish keys in the following quantities:
1. 1 each Grand Masterkeys
2. 4 each Masterkeys
3. 2 each Change keys each keyed core
4. 15 each Construction masterkeys
5. 1 each Control keys
F. The Owner, or the Owner's agent, will install permanent cores and return the construction cores to the Hardware Supplier. Construction cores and keys remain the property of the Hardware Supplier.
G. Keying Schedule: Arrange for a keying meeting, and programming meeting with Architect Owner and hardware supplier, and other involved parties to ensure locksets and locking hardware, are functionally correct and keying and programming complies with project requirements. Furnish 3 typed copies of keying and programming schedule to Architect.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Verification of conditions: Examine doors, frames, related items and conditions under which Work is to be performed and identify conditions detrimental to proper and or timely completion.
1. Do not proceed until unsatisfactory conditions have been corrected.
3.2 HARDWARE LOCATIONS:
A. Mount hardware units at heights indicated in the following publications except as specifically indicated or required to comply with the governing regulations.
1. Recommended Locations for Builder’s Hardware for Standard Steel Doors and Frames, by the Door and Hardware Institute (DHI).
2. Recommended locations for Architectural Hardware for flush wood doors (DHI).
3. WDMA Industry Standard I.S.-1A-04, Industry Standard for Architectural wood flush doors.
3.3 INSTALLATION:
A. Install each hardware item per manufacturer's instructions and recommendations. Do not install surface mounted items until finishes have been completed on the substrate. Set units level, plumb and true to line and location. Adjust and reinforce the attachment substrate as necessary for proper installation and operation.
B. Conform to local governing agency security ordinance.
Wilkes-Barre, Pennsylvania
C. Install Conforming to ICC/ANSI A117.1 Accessible and Usable Building and Facilities.
1. Adjust door closer sweep periods so that from the open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 inches from the latch, measured to the landing side of the door.
D. Installed hardware using the manufacturers fasteners provided. Drill and tap all screw holes located in metallic materials. Do not use “Riv-Nuts” or similar products.
3.4 FIELD QUALITY CONTROL AND FINAL ADJUSTMENT
A. Contractor/Installers, Field Services: After installation is complete, contractor shall inspect the completed door openings on site to verify installation of hardware is complete and properly adjusted, in accordance with both the Contract Documents and final shop drawings.
1. Check and adjust closers to ensure proper operation.
2. Check latchset, lockset, and exit devices are properly installed and adjusted to ensure proper operation.
a. Verify levers are free from binding.
b. Ensure latchbolts and dead bolts are engaged into strike and hardware is functioning.
3. Report findings, in writing, to architect indicating that all hardware is installed and functioning properly. Include recommendations outlining corrective actions for improperly functioning hardware if required.
3.5 SCHEDULE OF FINISH HARDWARE:
Manufacturer List
Code Name AB ABH Manufacturing Inc.
AIPH AIPH
BM Bommer Industries DM Dorma Door Controls NA National Guard YA Yale SD Stanley Door Closers SPEC Special Lite ST Stanley TR Trimco
Wilkes-Barre, Pennsylvania
Option List
Code Description 6 2-1/4" Door Thickness
C QUICK CONNECT WIRING OPTION
C Quick Connect Wiring System N Thru-Bolt w/ Flow-Thru
CD CYLINDER DOGGING
FL Fire Exit Hardware FP Fire Studs for 3 Hr. Fire Rating LD Less Dogging 3RO Prefix option for 2000 Apex Series AVB Advanced Variable Backcheck CSK COUNTER SINKING OF KICK and MOP PLATES
LBR LESS BOTTOM ROD
MLR MOTORIZED LATCH RETRACTION
VIB Double Visual Indictor Option VIT Visual Indictor Thumb-Turn
S300 STD. STRIKE - RIM AND TOP OF SVR DEVICES
S988 STANDARD. STRIKE - NARROW STILE RIM
CA-03 Cylinder Attachment Kit (Rim/SVR Device) 2-1/4" 2-1/4" Thick Doors
CSK-AP COUNTER SINKING OF ARMOUR PLATES
P45-113 Extra Clearance Offset Brkt.
EPT Prep EPT Prep (full mortise) P45-180D Drop Plate for Narrow Top Rail P45HD-110 Spacer Block HD Arm on Rabbet P45HD-112 Angle Brkt. - Shoe Support HD Arms
B4E-HEAVY-AP BEVELED 4 EDGES - ARMOR PLATES
B4E-HEAVY-KP BEVELED 4 EDGES - KICK PLATES
10-24 SSMS/LA STAINLESS MACHINE SCREWS/LEAD ANCHOR
Cut to Length Cut to Lenght (Specify) Spec. Thickness Special Door Thickness (Specify)
Finish List
Code Description AL Aluminum 626 Satin Chromium Plated 628 Satin Aluminum, Clear Anodized 630 Satin Stainless Steel 652 Satin Chromium Plated 689 Aluminum Painted GREY Grey BLACK Black
Wilkes-Barre, Pennsylvania
US26D Chromium Plated, Dull US32D Stainless Steel, Dull
Hardware Sets
SET #01
Doors: 301A, 301B, 401A, 401B
1 Continuous Hinge 661HD UL Cut to length as required AL ST 1 Continuous Hinge 661HD UL EPT Cut to length as req. AL ST 1 Removable Mullion KR-SL60 628 SPEC 1 Exit Device 3RO C MLR 2103 CA-03 S988 x door thickness as 630 PR req.
1 Exit Device 3RO 2101 LD S988 x door thickness as req. 630 PR 1 Rim Cylinder Match VAMC Master Key System 626 YA 1 Mortise Cylinder Match VAMC Master Key System 626 YA 1 Anti-Vandal Pull 1097PHI-21S-CS4 x door thickness as req. 630 TR 2 Door Closer CLD-4551 EDA AVB P45-180D P45HD-110 689 SD
P45HD-112
2 Overhead Stop 102X SL x size and door thickness as required US32D AB 2 Door Position Switch MC7 DM 2 Door Sweep C699A x LAR NA 1 Saddle Threshold 425 x LAR x 10-24 SSMS/LA AL NA
NOTE: Perimeter frame and door meeting stile weatherstrip to be furnished by the door and frame manufacturer.
SET #02
Doors: B207A, B207B, B235
3 Hinges CB168 4 1/2 X 4 1/2 NRP US26D ST 1 Electro-mech Lock Match VAMC Master Key System 626 YA 1 Door Closer CLD-4551 EDA AVB 689 SD 1 Kick Plate K0050 10" x 2" LDW x B4E-Heavy x CSK 630 TR 1 Convex Wall Stop 1270CX 626 TR 1 Wire Harness WH-XX x coordinate with door for LAR ST 1 Power Transfer EPT-12C PR 1 Wire Harness WH-192P ST 1 Door Position Switch MC7 DM 3 Door Silencers 1229A GREY TR
NOTE: Card reader, controller, head-end, software and infrastructure to be provided by the access control supplier. Presentation of a valid card unlocks the outside lever so that the latch can be retracted and the door opened. The door position switch monitors the door for door prop.
Wilkes-Barre, Pennsylvania
END OF SECTION 087100
| PART 1 - GENERAL |
| 1.1 SUMMARY: |
| A. Section Includes: Finish Hardware for door openings, except as otherwise specified herein. |
| B. Related Sections: |
| C. References: Comply with applicable requirements of the following standards. Where these standards conflict with other specific requirements, the most restrictive shall govern. |
| D. Intent of Hardware Groups |
| E. Alternates |
| 1.2 SUBSTITUTIONS: |
| A. Comply with Division 1. |
| 1.3 SUBMITTALS: |
| A. Comply with Division 1. |
| B. Special Submittal Requirements: Combine submittals of this Section with Sections listed below to ensure the "design intent" of the system/assembly is understood and can be reviewed together. |
| C. Product Data: Manufacturer's specifications and technical data including the following: |
| D. Shop Drawings - Hardware Schedule: Submit 6 complete reproducible copy of detailed hardware schedule in a vertical format. |
| E. Templates: Submit templates and "reviewed Hardware Schedule" to door and frame supplier and others as applicable to enable proper and accurate sizing and locations of cutouts and reinforcing. |
| F. Samples: (If requested by the Architect) |
| G. Contract Closeout Submittals: Comply with Division 1 including specific requirements indicated. |
| 1.4 QUALITY ASSURANCE |
| A. Comply with Division 1. |
| B. Review Project for extent of finish hardware required to complete the Work. Where there is a conflict between these Specifications and the existing hardware, notify the Architect in writing and furnish hardware in compliance with the Specification unless otherwise directed in writing by the Architect. Furnish custom strikes, door wrap-arounds as needed. Existing frames and doors may need modification for new hardware as specified. Call out any discrepancies to the architect when submitting shop drawings for approval or before submission. |
| 1.5 DELIVERY, STORAGE, AND HANDLING |
| A. Packing and Shipping: Comply with Division 1. |
| B. Storage and Protection: Comply with manufacturer's recommendations. |
| 1.6 PROJECT CONDITIONS: |
| A. Coordinate hardware with other work. Furnish hardware items of proper design for use on doors and frames of the thickness, profile, swing, security and similar requirements indicated, as necessary for the proper installation and function, regardless of omissions or conflicts in the information on the Contract Documents. |
| B. Review Shop Drawings for doors and entrances to confirm that adequate provisions will be made for the proper installation of hardware. |
| 1.7 WARRANTY: |
| A. Refer to Conditions of the Contract |
| B. Manufacturer’s Warranty: |
| 1.8 OWNER’S INSTRUCTION: |
| A. Instruct Owner’s personnel in operation and maintenance of hardware units. |
| 1.9 MAINTENANCE: |
| A. Extra Service Materials: Deliver to Owner extra materials from same production run as products installed. Package products with protective covering and identify with descriptive labels. Comply with Division 1 Closeout Submittals Section. |
| B. Maintenance Service: Submit for Owner’s consideration maintenance service agreement for electronic products installed. |
| PART 2 - PRODUCTS |
| 2.1 MANUFACTURERS: |
| A. The following manufacturers are approved subject to compliance with requirements of the Contract Documents. Approval of manufacturers other than those listed shall be in accordance with Division 1. |
| 2.2 MATERIALS: |
| A. Hinges: |
| B. Geared Continuous Hinges: |
| C. Mortise Type Locks and Latches: |
| D. Mortise Deadbolt: |
| E. Exit Devices shall: |
| F. Cylinders: |
| G. Door Closers shall: |
| H. Door Stops: Provide a dome floor or wall stop for every opening as listed in the hardware sets. |
| I. Over Head Stops: Provide a Surface mounted or concealed overhead when a floor or wall stop cannot be used or when listed in the hardware set. |
| J. Push Plates: Provide with four beveled edges ANSI J301, .050 thickness, size as indicated in hardware set. Furnish oval-head countersunk screws to match finish. |
| K. Pulls with plates: Provide with four beveled edges ANSI J301, .050 thickness Plate s with ANSI J401 Pull as listed in hardware set. Provide proper fasteners for door construction. |
| L. Kickplates: Provide with four beveled edges ANSI J102, 10 inches high by width less 2 inches on single doors and 1 inch on pairs of doors. Furnish oval-head countersunk screws to match finish. |
| M. Armor Plates: Provide ANSI J101 with four beveled edges, 40 inches high by width less 1 inch on single or pairs of doors. Furnish oval-head countersunk screws to match finish. |
| N. Door Bolts: Flush bolts for wood or metal doors. |
| O. Coordinator and Brackets: Provide a surface mounted coordinator when automatic bolts are used in the hardware set. |
| P. Quick Connect Power Transfer: Power transfer device shall be a steel housing and flexible tube. Secure and inconspicuous channel is to bring power from the frame to the door. |
| Q. Surface mounted Door Loop Power Transfer: Armored flex conduit is to bring power from the frame to the door. The tube shall accept up to 1/4” wire bundle and is 18” long. |
| R. Power Supply: Provide power supply PS873 series for Electric Latch Retraction exit devices. Provide the appropriate control circuit card necessary to operate the number of EL exit devices used at each opening. Example PS873X2 |
| S. Power Transfer: Power transfer device shall be a steel housing and flexible tube. Secure and inconspicuous channel is to bring power from the frame to the door. |
| T. Electromagnetic Locks: Certified by BHMA for A156.23; electrically powered, of strength and configuration indicated; with electromagnet attached to frame and armature plate attached to door |
| U. Power Supply: UL Listed, Field Selectable 12VDC or 24VDC output. The power supply will specifically be designed to support electric locks and access controls. The power supply uses 115 VACS at 800mA input. The power shall be able to be expanded to four station controls. The filtered and regulated output power is field selectable for 12 or 24 VDC. |
| V. Electric Door Strike: Certified by ANSI/BHMA 156.31, Grade 1. and listed for Burglary Protection ANSI/ UL1034 Grade 1. |
| W. Door Position Switch: Provide door position switch for door status monitoring as indicated in hardware sets. |
| X. Quick Connect plug-in connectors: Stanley quick connect plug-in must be used with a combination of the following components to work as a complete plug and play system. |
| Y. Quick Connect Wire Harnesses: The Quick Connect wire harness shall have of one four wire connector and one eight wire connector. The four-wire connector has two 18AWG and two 24AWG wires. The eight-wire connector has eight 24AWG wires Stanley quick connect wire harnesses are available in various length’s, 3” (76mm), 6” (152mm), 12” (304mm), 26” (660mm) 32” (812mm) 38” (965mm), 44” (1117mm), 50” (1270mm) and 192” (4876mm). |
| Z. Magnetic Door Holders: Provide magnetic door holders with Tri-Voltage that can be wired 12VDC, 24V AC/DC or 120V AC |
| AA. Seals: All seals shall be finished to match adjacent frame color. Seals shall be furnished as listed in schedule. Material shall be UL listed for labeled openings. |
| BB. Weatherstripping: Provide at head and jambs only those units where resilient or flexible seal strip is easily replaceable. Where bar-type weatherstrip is used with parallel arm mounted closers install weatherstrip first. |
| CC. Door Bottoms/Sweeps: Surface mounted or concealed door bottom where listed in the hardware sets. |
| DD. Thresholds: Thresholds shall be aluminum beveled type with maximum height of ½” for conformance with ADA requirements. Furnish as specified and per details. Provide fasteners and screws suitable for floor conditions. |
| EE. Provide one wall mounted Telkee, Lund or MMF series key cabinet complete with hooks, index and tags to accommodate 50% expansion. Coordinate mounting location with architect. |
| FF. Keystone Web Key Management Software: Provide one, Keystone Web product “KSWN” key management software. Shall include |
| GG. Silencers: Furnish silencers on all interior frames, 3 for single doors, 2 for pairs. Omit where any type of seals occur. |
| 2.3 FINISH: |
| A. Designations used in Schedule of Finish Hardware - 3.05, and elsewhere to indicate hardware finishes are those listed in ANSI/BHMA A156.18 including coordination with traditional U.S. finishes shown by certain manufacturers for their products |
| B. Powder coat door closers to match other hardware, unless otherwise noted. |
| C. Aluminum items shall be finished to match predominant adjacent material. Seals to coordinate with frame color. |
| 2.4 KEYS AND KEYING: |
| A. Provide keyed brass construction cores and keys during the construction period. Construction control and operating keys and core shall not be part of the Owner's permanent keying system or furnished in the same keyway (or key section) as the Owner's permanent keying system. Permanent cores and keys (prepared according to the accepted keying schedule) will be furnished to the Owner. |
| B. Cylinders, removable and interchangeable core system. Yale Locksets matching the existing VAMC system is the only locksets to be provided. |
| C. Permanent keys and cores: Stamped with the applicable key mark for identification. These visual key control marks or codes will not include the actual key cuts. Permanent keys will also be stamped "Do Not Duplicate." |
| D. Transmit Grand Masterkeys, Masterkeys and other Security keys to Owner by Registered Mail, return receipt requested. |
| E. Furnish keys in the following quantities: |
| F. The Owner, or the Owner's agent, will install permanent cores and return the construction cores to the Hardware Supplier. Construction cores and keys remain the property of the Hardware Supplier. |
| G. Keying Schedule: Arrange for a keying meeting, and programming meeting with Architect Owner and hardware supplier, and other involved parties to ensure locksets and locking hardware, are functionally correct and keying and programming complies with project requirements. Furnish 3 typed copies of keying and programming schedule to Architect. |
| PART 3 - EXECUTION |
| 3.1 EXAMINATION |
| A. Verification of conditions: Examine doors, frames, related items and conditions under which Work is to be performed and identify conditions detrimental to proper and or timely completion. |
| 3.2 HARDWARE LOCATIONS: |
| A. Mount hardware units at heights indicated in the following publications except as specifically indicated or required to comply with the governing regulations. |
| 3.3 INSTALLATION: |
| A. Install each hardware item per manufacturer's instructions and recommendations. Do not install surface mounted items until finishes have been completed on the substrate. Set units level, plumb and true to line and location. Adjust and reinforce the attachment substrate as necessary for proper installation and operation. |
| B. Conform to local governing agency security ordinance. |
| C. Install Conforming to ICC/ANSI A117.1 Accessible and Usable Building and Facilities. |
| D. Installed hardware using the manufacturers fasteners provided. Drill and tap all screw holes located in metallic materials. Do not use “Riv-Nuts” or similar products. |
| 3.4 FIELD QUALITY CONTROL AND FINAL ADJUSTMENT |
| A. Contractor/Installers, Field Services: After installation is complete, contractor shall inspect the completed door openings on site to verify installation of hardware is complete and properly adjusted, in accordance with both the Contract Documents and final shop drawings. |
3.5 SCHEDULE OF FINISH HARDWARE:
File details come from the government source that posted it. Updated .