This solicitation package outlines requirements for a construction project to build a new parking garage at the Wilkes-Barre VA Medical Center campus in Pennsylvania. The project scope includes providing all labor, materials, tools and equipment to construct a parking structure accommodating approximately 435 vehicles according to the drawings and specifications. The magnitude of the project is estimated between $10-20 million. Temporary interior signage requirements during construction are also specified. Signs will be printed on white paper tags tied with wire to room doors to identify room numbers as designated on floor plans. This procurement is set aside for verified service-disabled veteran-owned small businesses and utilizes a tiered evaluation process considering both small and large businesses. Pricing must be submitted in whole dollar amounts. The selected contractor will be responsible for correct worker classification and wage compliance.
View the file
Other files for this federal contract opportunity
Show all 50
Y1LZ--693-222 | Parking Structure Solicitation Amendment 2 has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PARKING GARAGE PROJECT NUMBER 693-222
DEPARTMENT OF VETERANS AFFAIRS
WILKES-BARRE, PENNSYLVANIA
SECTION 01 58 16
TEMPORARY INTERIOR SIGNAGE
PART 1 GENERAL
DESCRIPTION
This section specifies temporary interior signs.
PART 2 PRODUCTS
2.1 TEMPORARY SIGNS
| A. | Fabricate from 50 Kg (110 pound) mat finish white paper. |
| B. | Cut to 100 mm (4-inch) wide by 300 mm (12 inch) long size tag. |
| C. | Punch 3 mm (1/8-inch) diameter hole centered on 100 mm (4-inch) dimension of tag. Edge of Hole spaced approximately 13 mm (1/2-inch) from one end on tag. |
| D. | Reinforce hole on both sides with gummed cloth washer or other suitable material capable of preventing tie pulling through paper edge. |
| E. | Ties: Steel wire 0.3 mm (0.0120-inch) thick, attach to tag with twist tie, leaving 150 mm (6-inch) long free ends. |
PART 3 EXECUTION
3.1 INSTALLATION
| A. | Install temporary signs attached to room door frame or room door knob, lever, or pull for doors on corridor openings. |
| B. | Mark on signs with felt tip marker having approximately 3 mm (1/8-inch) wide stroke for clearly legible numbers or letters. |
| C. | Identify room with numbers as designated on floor plans. |
3.2 LOCATION
| A. | Install on doors that have room, corridor, and space numbers shown. |
| B. | Doors that do not require signs are as follows: |
| 1. | Corridor barrier doors (cross-corridor) in corridor with same number. |
| 2. | Folding doors or partitions. |
| 3. | Toilet or bathroom doors within and between rooms. |
| 4. | Communicating doors in partitions between rooms with corridor entrance doors. |
| 5. | Closet doors within rooms. |
| C. | Replace missing, damaged, or illegible signs. |
- - - E N D - - - 01 58 16 - 1