084113 Aluminum Storefront Systems.pdf

PDF 106 KB Posted

Attached to
Y1LZ--693-222 | Parking Structure Solicitation Amendment 2 Federal contract opportunity
Solicitation number
36C24420R0075
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 4

About this file

This document package includes a specification section and related federal contract opportunity. The specification section outlines requirements for aluminum storefront systems for a parking garage project at the Wilkes-Barre VA Medical Center in Pennsylvania. Key details include YKK AP being specified as the basis of design for storefront framing, entrance doors, and windows. The project involves constructing a new parking garage to accommodate approximately 435 vehicles.

The related federal contract opportunity is a solicitation amendment for Project 693-222 to construct the parking garage. The magnitude of the project is between $10-20 million, with a NAICS code of 236220 for commercial and institutional building construction. This is a set-aside for Service-Disabled Veteran-Owned Small Businesses utilizing tiered evaluation procedures down to the large business tier. The contractor will be responsible for correct worker classification and wage compliance. Pricing must be in whole dollars. The solicitation may be canceled before award but after closing if in the government's best interest.

View the file

Other files for this federal contract opportunity

Other files attached to Y1LZ--693-222 | Parking Structure Solicitation Amendment 2, newest first.
File Type Posted
015000TempFacilitiesControls.pdf PDF
097753 Living Wall System.pdf PDF
074515 Composite Wall Panel.pdf PDF
VMAC_Sketch_SKE-1.pdf PDF
S02 Solicitation 36C24420R0075 AMD 0001.pdf PDF
P03 JA Tyco SimplexGrinnell.pdf PDF
P03 JA Johnson Controls.pdf PDF
36C24420R0075_4.docx DOCX document
2903 312000 Earthwork 02.pdf PDF
280800.pdf PDF
262726.pdf PDF
230800.pdf PDF
221400.pdf PDF
221300.pdf PDF
220523.pdf PDF
210800.pdf PDF
210512.pdf PDF
111200 Parking Control Equipment.pdf PDF
099600 High Performance Coatings.pdf PDF
079020 Garage Waterproofing Systems.tha.pdf PDF
078410 Through Penetration Firestop Systems.pdf PDF
071113 Bituminous Dampproofing.pdf PDF
061000 Rough Carpentry.pdf PDF
055000 Metal Fabrications.pdf PDF
051200 Structural Steel Framing.pdf PDF
034500 Precast Architectural Concrete.pdf PDF
017900 Warranties_Single Prime.pdf PDF
017823 Operation and Maintenance Data_Single Prime.pdf PDF
015000 Temporary Facilities _ Controls_Single Prime.pdf PDF
014535.docx DOCX document
013100 Project Coordination_Single Prime.pdf PDF
012800 Field Engineering_Single Prime.pdf PDF
012600 Modification Procedures_Single Prime.pdf PDF
000000 Table of Contents_Single Prime 02.docx DOCX document
Arch Dwg 11-16.pdf PDF
S02 Dwg C2-E2.pdf PDF
S02 Parking Structure List of Dwgs.pdf PDF
EXHIBIT D - Sample Transmittal Letter for Past Performance Evaluation Questionnaire.docx DOCX document
EXHIBIT A - Past Performance Relevancy Questionnaire.docx DOCX document
334000 Storm Sewer Utilities.pdf PDF
316326 Drilled Caissons.pdf PDF
312319 Dewatering.pdf PDF
280526.pdf PDF
264313.pdf PDF
280500.pdf PDF
260533.pdf PDF
260519.pdf PDF
260511.pdf PDF
230711.pdf PDF
220800.pdf PDF
Show all 50

Y1LZ--693-222 | Parking Structure Solicitation Amendment 2 has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Parking Garage Project Number 693-222 Department of Veterans Affairs Wilkes-Barre, Pennsylvania

SECTION 084113 - ALUMINUM STOREFRONT SYSTEMS

PART 1 – GENERAL

1.1 RELATED DOCUMENTS

A. Drawings, Division 0 - Bidding and Contract Requirements and Division 1 General Requirements apply to this Section.

1.2 SUMMARY

A. This Section includes the following:

1. Exterior and interior storefront framing.

2. Exterior and interior manual-swing entrance doors.

3. Operable window units within storefront systems.

B. Related sections include the following:

1. Division 7 Section "Joint Sealants" for joint sealants installed as part of aluminum entrance and storefront systems.

2. Division 8 Section "Glazing."

3. Division 8 Section “Door Hardware.”

1.3 SYSTEM DESCRIPTION

A. General: Provide aluminum entrance system capable of withstanding loads and thermal and structural movement requirements indicated without failure, based on testing manufacturer's standard units in assemblies similar to those indicated for this Project.

Failure includes the following:

1. Air infiltration and water penetration exceeding specified limits.

2. Framing members transferring stresses, including those caused by thermal and structural movement, to glazing units.

B. Glazing: Physically and thermally isolate glazing from framing members.

C. Glazing-to-Glazing Joints: Provide glazing-to-glazing joints that accommodate thermal and mechanical movements of glazing and system, prevent glazing-to-glazing contact, and maintain required edge clearances.

Wilkes-Barre, Pennsylvania

D. Thermally Broken Construction: Provide systems that isolate aluminum exposed to exterior from aluminum exposed to interior with a material of low thermal conductance.

E. Wind Loads: Provide entrance and storefront systems, including anchorage, capable of withstanding wind-load design pressures calculated according to requirements of authorities having jurisdiction or the American Society of Civil Engineers' ASCE 7, "Minimum Design Loads for Buildings and Other Structures," 6.4.2, "Analytical Procedure," whichever are more stringent.

1. Deflection of framing members in a direction normal to wall plane is limited to 1/175 of clear span or 3/4 inch, whichever is smaller, unless otherwise indicated.

2. Static-Pressure Test Performance: Provide entrance and storefront systems that do not evidence material failures, structural distress, failure of operating components to function normally, or permanent deformation of main framing members exceeding

0.2 percent of clear span when tested according to ASTM E 330.

a. Test Pressure: 150 percent of inward and outward wind-load design pressures.

b. Duration: As required by design wind velocity; fastest 1 mile of wind for relevant exposure category.

F. Dead Loads: Provide entrance- and storefront-system members that do not deflect an amount which will reduce glazing bite below 75 percent of design dimension when carrying full dead load.

1. Provide a minimum 1/8-inch clearance between members and top of glazing or other fixed part immediately below.

2. Provide a minimum 1/16-inch clearance between members and operable windows and doors.

G. Live Loads: Provide entrance and storefront systems, including anchorage, that accommodate the supporting structures' deflection from uniformly distributed and concentrated live loads indicated without failure of materials or permanent deformation.

H. Air Infiltration: Provide entrance and storefront systems with permanent resistance to air leakage through fixed glazing and frame areas of not more than 0.04 cfm/sq. ft. of fixed wall area when tested according to ASTM E 283 at a static-air-pressure difference of 6.24 lbf/sq.

ft.

I. Water Penetration: Provide entrance and storefront systems that do not evidence water leakage through fixed glazing and frame areas when tested according to ASTM E 331 at minimum differential pressure of 20 percent of inward-acting wind-load design pressure as defined by ASCE 7, "Minimum Design Loads for Buildings and Other Structures," but not less than 15.0 lbf/sq. ft. Water leakage is defined as follows:

1. Uncontrolled water infiltrating systems or appearing on systems' normally exposed interior surfaces from sources other than condensation. Water controlled by flashing

Wilkes-Barre, Pennsylvania and gutters that is drained back to the exterior and cannot damage adjacent materials or finishes is not water leakage.

J. Thermal Movements: Provide entrance and storefront systems, including anchorage, that accommodate thermal movements of systems and supporting elements resulting from the following maximum change (range) in ambient and surface temperatures without buckling, damaging stresses on glazing, failure of joint sealants, damaging loads on fasteners, failure of doors or other operating units to function properly, and other detrimental effects.

1. Temperature Change (Range): 120 deg F, ambient; 180 deg F, material surfaces.

K. Structural-Support Movement: Provide entrance and storefront systems that accommodate structural movements including, but not limited to, sway and deflection.

L. Condensation Resistance: Provide storefront systems with condensation resistance factor (CRF) of not less than 45 for the frame when tested according to AAMA 1503.1.

M. Average Thermal Conductance: Provide storefront systems with average U-values of not more than 0.45 Btu/sq. ft. x h x deg F when tested according to AAMA 1503.1.

N. Dimensional Tolerances: Provide entrance and storefront systems that accommodate dimensional tolerances of building frame and other adjacent construction.

O. Performance Requirements of Operable Units: Testing shall demonstrate compliance with requirements indicated in AAMA 101-03 for air infiltration, water penetration, and structural performance for type, grade, and performance class of window units required. Where required design pressure exceed the minimum for specified window grade, comply with requirements of AAMA 101, Section 3, “Optional Performance Classes,” for higher than minimum performance class.

1. Air-infiltration Rate for Operating Units: Not more than 0.10 cfm/ft. of operable sash joint for an inward test pressure of 6.24 lbf/sq.ft.

2. Air infiltration Rate for Fixed Windows: Not more than 0.06 cfm/ft. of area for an inward test pressure of 6.24 lbf/sq.ft.

3. Water Penetration: No water penetration as defined in the test method at an inward test pressure of 20 percent of the design pressure (12psf)

4. Uniform Load Deflection: No deflection in excess of 1/175 of any member’s span during the imposed load, for a positive (inward) and negative (outward) test pressure of 60 lbf/sq.ft

5. Structural Performance: No failure or permanent deflection in excess of 0.4 percent of any member’s span after removing the imposed load, for a positive (inward) and negative (outward) test pressure of 105 psf.

Wilkes-Barre, Pennsylvania

6. Condensation Resistance: Where window units are indicated to be “thermally improved,” provide units tested for thermal performance according to AAMA 1503.1 showing a condensation resistance factor (CRF) of 59 (frame).

7. Thermal Movements: Provide window units that allow thermal movement resulting from the following maximum change (range) in ambient temperature when engineering, fabricating, and installing aluminum windows to prevent buckling, opening of joints, and overstressing of components, connections, and other detrimental effects.

Base engineering calculation on actual surface temperatures of materials due to solar heat gain and nighttime sky heat loss.

8. Temperature Change (Range): 120 deg F, ambient; 180 deg F, material surfaces.

1.4 SUBMITTALS

A. Product Data: For each product specified. Include details of construction relative to materials, dimensions of individual components, profiles, and finishes.

B. Shop Drawings: For entrance system. Show details of fabrication and installation, including plans, elevations, sections, details of components, provisions for expansion and contraction, and attachments to other work.

1. Layout and installation details, including anchors.

Elevations at ¼ inch = 1 foot (1:50) scale and typical window unit elevations at ¾ inch = 1 foot (1:20) scale.

Full-size section details of typical composite members, including reinforcement and stiffeners.

Location of weep holes.

Hardware, including operators.

Glazing details.

Accessories

C. Samples for Verification: Of each type of exposed finish required in manufacturer's standard sizes. Where finishes involve normal color and texture variations, include Sample sets showing the full range of variations expected.

D. Cutaway Sample: Of each vertical-to-horizontal framing intersection of systems, made from minimum 6-inch lengths of full-size components and showing details of the following:

1. Joinery.

2. Anchorage.

3. Expansion provisions.

4. Glazing.

5. Flashing and drainage.

6. Structural-sealant joints.

Wilkes-Barre, Pennsylvania

E. Installer Certificates: Signed by manufacturer certifying that installers comply with specified requirements.

F. Sealant Compatibility and Adhesion Test Reports: From sealant manufacturer, indicating that materials forming joint substrates and joint-sealant backings have been tested for compatibility and adhesion with sealants; include joint sealant manufacturers' written interpretation of test results relative to sealant performance and recommendations for primers and substrate preparation needed to obtain adhesion.

G. Product Test Reports: Based on evaluation of tests performed by manufacturer and witnessed by a qualified independent testing agency, indicate compliance of entrance and storefront systems with requirements based on comprehensive testing of current systems.

1.5 QUALITY ASSURANCE

A. Installer Qualifications: Engage an experienced installer to assume engineering responsibility and perform work of this Section who has specialized in installing entrance and storefront systems similar to those required for this Project and who is acceptable to manufacturer.

1. Engineering Responsibility: Prepare data for entrance and storefront systems, including Shop Drawings, based on testing and engineering analysis of manufacturer's standard units in assemblies similar to those indicated for this Project.

B. Source Limitations: Obtain each type of entrance, storefront framing, and curtain wall system through one source from a single manufacturer.

C. Product Options: Drawings indicate size, profiles, and dimensional requirements of entrance and storefront systems and are based on the specific systems indicated. Other manufacturers' systems with equal performance characteristics may be considered. Refer to Division 1 Section "Substitutions."

1. Do not modify intended aesthetic effect, as judged solely by Architect, except with Architect's approval and only to the extent needed to comply with performance requirements. Where modifications are proposed, submit comprehensive explanatory data to Architect for review.

D. Welding Standards: Comply with applicable provisions of AWS D1.2, "Structural Welding Code--Aluminum."

1.6 PROJECT CONDITIONS

A. Field Measurements: Verify dimensions by field measurements before fabrication and indicate measurements on Shop Drawings. Coordinate fabrication schedule with construction progress to avoid delaying the Work.

1. Established Dimensions: Where field measurements cannot be made without delaying the Work, establish dimensions and proceed with fabricating systems

Wilkes-Barre, Pennsylvania without field measurements. Coordinate construction to ensure actual dimensions correspond to established dimensions.

Wilkes-Barre, Pennsylvania

1.7 WARRANTY

A. General Warranty: The special warranty specified in this Article shall not deprive the Owner of other rights the Owner may have under other provisions of the Contract Documents and shall be in addition to, and run concurrent with, other warranties made by the Contractor under requirements of the Contract Documents.

B. Special Warranty: Submit a written warranty executed by the manufacturer agreeing to repair or replace components of entrance and storefront systems that fail in materials or workmanship within the specified warranty period. Failures include, but are not limited to, the following:

1. Structural failures including, but not limited to, excessive deflection.

2. Adhesive sealant failures.

3. Cohesive sealant failures.

4. Failure of system to meet performance requirements.

5. Deterioration of metals, metal finishes, and other materials beyond normal weathering.

6. Failure of operating components to function normally.

7. Water leakage through fixed glazing and frame areas.

C. Warranty Period: 2 years from date of Substantial Completion.

1. Special Warranty: Submit a written warranty signed by aluminum window manufacturer agreeing to repair or replace window components that fail in materials or workmanship within the specified warranty period. Failures include, but are not limited to the following:

a. Structural failures including excessive deflection, water leakage, air infiltration, or condensation.

b. Faulty operation of sash and hardware.

c. Deterioration of metals, metal finishes, and other materials beyond normal weathering.

2. Warranty Period for Metal Finishes: 10 years from date of Substantial Completion.

3. Warranty Period: 2 years from date of Substantial Completion.

PART 2 – PRODUCTS

2.1 MANUFACTURERS

A. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following.

Wilkes-Barre, Pennsylvania

1. (Basis of Design) YKKAP America Inc. – YES 45TU 2”X4½” storefront system with YKK AP “YOW 225 TU ThermaBond Plus Aluminum Window System.

Doors: 50D Wide stile Door, 5” Wide Stiles, 8” Top Rail, 10-3/4” Bottom Rail

2. Kawneer Company, Inc.

3. EFCO Corporation.

4. Butler Manufacturing Company.

2.2 MATERIALS

A. Aluminum: Alloy and temper recommended by manufacturer for type of use and finish indicated, complying with the requirements of standards indicated below.

1. Sheet and Plate: ASTM B 209 (ASTM B 209M).

2. Extruded Bars, Rods, Shapes, and Tubes: ASTM B 221 (ASTM B 221M).

3. Extruded Structural Pipe and Tubes: ASTM B 429.

4. Bars, Rods, and Wire: ASTM B 211 (ASTM B 211M).

5. Welding Rods and Bare Electrodes: AWS A5.10.

B. Steel Reinforcement: Complying with ASTM A 36 (ASTM A 36M) for structural shapes, plates, and bars; ASTM A 611 for cold-rolled sheet and strip; or ASTM A 570 (ASTM A 570M) for hot-rolled sheet and strip.

C. Glazing as specified in Division 8 Section "Glazing."

D. Glazing Gaskets: Manufacturer's standard pressure-glazing system of black, resilient glazing gaskets, setting blocks, and shims or spacers, fabricated from an elastomer of type and in hardness recommended by system and gasket manufacturer to comply with system performance requirements. Provide gasket assemblies that have corners sealed with sealant recommended by gasket manufacturer.

E. Spacers, Setting Blocks, Gaskets, and Bond Breakers: Manufacturer's standard permanent, nonmigrating types in hardness recommended by manufacturer, compatible with sealants, and suitable for system performance requirements.

F. Structural Silicone Sealant: Type recommended by sealant and system manufacturers that complies with ASTM C 1184 requirements, is compatible with system components with which it comes in contact, and is specifically formulated and tested for use as a structural sealant.

1. Color: As selected by Architect from manufacturer's full range of colors.

2. Tensile Strength: 100 psi (689.5 kPa) minimum.

3. Provide sealant with modulus of elasticity that will not allow movement of more than

25 percent of joint width, unless less movement is required by structural-sealant-glazed systems' design.

4. Use neutral-cure silicone sealant with insulating-glass units.

Wilkes-Barre, Pennsylvania

G. Secondary Sealant: For use as weatherseal, compatible with structural silicone sealant and other system components with which it comes in contact, and that accommodates a 50 percent increase or decrease in joint width at the time of application when measured according to ASTM C 719.

1. Color: As selected by Architect from manufacturer's full range of colors.

2. Use neutral-cure silicone sealant with insulating-glass units.

H. Framing system gaskets, sealants, and joint fillers as recommended by manufacturer for joint type.

I. Sealants and joint fillers for joints at perimeter of entrance and storefront systems as specified in Division 7 Section "Joint Sealants."

J. Bituminous Paint: Cold-applied asphalt-mastic paint complying with SSPC-Paint 12 requirements, except containing no asbestos, formulated for 30-mil thickness per coat.

2.3 COMPONENTS

B. Entrance Doors: Manufacturer's standard glazed entrance doors for manual-swing operation.

Exterior Doors Basis of Design: YKK AP “50XT”, Interior Doors Basis of Design: YKK AP “50D”

1. Door Construction: Extruded-aluminum tubular rail and stile members. Mechanically fasten corners with reinforcing brackets that are deeply penetrated and fillet welded or that incorporate concealed tie rods.

a. Exterior doors to receive 1” insulated glazing units.

b. Interior doors to receive ¼” glazing units.

c. Exterior Door Thermal Construction: High-performance plastic connectors separate aluminum members exposed to the exterior from members exposed to the interior.

2. Door Design: Wide Stile: 5 inch side rails, 8 inch top rail, and 10 inch bottom rail.

a. Provide door stiles of adequate width and depth to accommodate specified door hardware and devices.

3. Glazing Stops and Gaskets: Square, snap-on, extruded-aluminum stops and preformed gaskets.

a. Provide nonremovable glazing stops on outside of door.

4. Double Doors

a. Accommodate removable center lockable mullion for double doors. Refer to Division 08 Section Door Hardware.

Wilkes-Barre, Pennsylvania

B. Brackets and Reinforcements: Provide manufacturer's standard brackets and reinforcements that are compatible with adjacent materials. Provide nonstaining, nonferrous shims for aligning system components.

C. Fasteners and Accessories: Manufacturer's standard corrosion-resistant, nonstaining, nonbleeding fasteners and accessories compatible with adjacent materials.

1. Reinforce members as required to retain fastener threads.

2. Do not use exposed fasteners, except for hardware application. For hardware application, use countersunk Phillips flat-head machine screws finished to match framing members or hardware being fastened, unless otherwise indicated.

D. Concealed Flashing: Manufacturer's standard corrosion-resistant, nonstaining, nonbleeding flashing, compatible with adjacent materials, and of type recommended by manufacturer.

E. Concrete and Masonry Inserts: Hot-dip galvanized cast-iron, malleable-iron, or steel inserts complying with ASTM A 123 or ASTM A 153 requirements.

F. Weather Stripping: Manufacturer's standard replaceable weather stripping as follows:

1. Compression Weather Stripping: Molded neoprene complying with ASTM D 2000 requirements or molded PVC complying with ASTM D 2287 requirements.

2.4 HARDWARE

A. All hardware specified in Section 087100.

2.5 GLAZING

C. Glazing: As specified in Section 088000 "Glazing."

2.6 FABRICATION

A. General: Fabricate components that, when assembled, will have accurately fitted joints with ends coped or mitered to produce hairline joints free of burrs and distortion. After fabrication, clearly mark components to identify their locations in Project according to Shop Drawings.

B. Forming: Form shapes with sharp profiles, straight and free of defects or deformations, before finishing.

C. Prepare components to receive concealed fasteners and anchor and connection devices.

Wilkes-Barre, Pennsylvania

D. Fabricate components to drain water passing joints and condensation and moisture occurring or migrating within the system to the exterior.

E. Welding: Weld components to comply with referenced AWS standard. Weld before finishing components to greatest extent possible. Weld in concealed locations to greatest extent possible to minimize distortion or discoloration of finish. Remove weld spatter and welding oxides from exposed surfaces by descaling or grinding.

F. Glazing Channels: Provide minimum clearances for thickness and type of glass indicated according to FGMA's "Glazing Manual."

G. Metal Protection: Where aluminum will contact dissimilar metals, protect against galvanic action by painting contact surfaces with primer or by applying sealant or tape recommended by manufacturer for this purpose. Where aluminum will contact concrete or masonry, protect against corrosion by painting contact surfaces with bituminous paint.

H. Entrances: Fabricate door framing in profiles indicated. Reinforce as required to support imposed loads. Factory assemble door and frame units and factory install hardware to greatest extent possible. Reinforce door and frame units as required for installing hardware indicated. Cut, drill, and tap for factory-installed hardware before finishing components.

1. Exterior Doors: Provide compression weather stripping at fixed stops. At other locations, provide sliding weather stripping retained in adjustable strip mortised into door edge.

2. Interior Doors: Provide ANSI/BHMA A156.16 silencers at stops to prevent metal to metal contact. Provide 3 silencers on strike jamb of single-door frames and 2 silencers on head of double-door frames.

2.7 ALUMINUM FINISHES

A. General: Comply with NAAMM's "Metal Finishes Manual for Architectural and Metal Products" for recommendations relative to applying and designating finishes.

B. Finish designations prefixed by AA conform to the system established by the Aluminum Association for designating aluminum finishes.

1. Color Anodic Finish: AAMA 611, AA-M12C22A42/A44, Class I, 0.7 mill (18 microns) or thicker. Color may not differ more than 5 Delta E, in accordance with ASTM D 523.

2. Color: As selected by Architect from full range of industry colors and color densities.

3. Provide 10 year finish warranty.

2.8 STEEL PRIMING

A. General: Comply with NAAMM's "Metal Finishes Manual for Architectural and Metal Products" for recommendations relative to applying primer.

Wilkes-Barre, Pennsylvania

B. Surface Preparation: Perform manufacturer's standard cleaning operations to remove dirt, oil, grease, or other contaminants that could impair paint bond. Remove mill scale and rust, if present, from uncoated steel.

C. Priming: Apply manufacturer's standard corrosion-resistant primer immediately after surface preparation and pretreatment.

PART 3 – EXECUTION

3.1 EXAMINATION

A. Examine areas, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of entrance and storefront systems.

Do not proceed with installation until unsatisfactory conditions have been corrected.

3.2 INSTALLATION

A. General: Comply with manufacturer's written instructions for protecting, handling, and installing entrance and storefront systems. Do not install damaged components. Fit frame joints to produce hairline joints free of burrs and distortion. Rigidly secure nonmovement joints. Seal joints watertight.

B. Metal Protection: Where aluminum will contact dissimilar metals, protect against galvanic action by painting contact surfaces with primer or by applying sealant or tape recommended by manufacturer for this purpose. Where aluminum will contact concrete or masonry, protect against corrosion by painting contact surfaces with bituminous paint.

C. Install components to drain water passing joints and condensation and moisture occurring or migrating within the system to the exterior.

D. Set continuous sill members and flashing in a full sealant bed to provide weathertight construction, unless otherwise indicated. Comply with requirements of Division 7 Section "Joint Sealants."

E. Install framing components plumb and true in alignment with established lines and grades without warp or rack of framing members.

F. Install entrances plumb and true in alignment with established lines and grades without warp or rack. Lubricate operating hardware and other moving parts according to hardware manufacturers' written instructions.

1. Install surface-mounted hardware according to manufacturer's written instructions using concealed fasteners to greatest extent possible.

G. Install glazing to comply with requirements of Division 8 Section "Glazing," unless otherwise indicated.

Wilkes-Barre, Pennsylvania

1. Prepare surfaces that will contact structural sealant according to sealant manufacturer's written instructions to ensure compatibility and adhesion.

Preparation includes, but is not limited to, cleaning and priming surfaces.

2. Install structural silicone sealant according to sealant manufacturer's written instructions.

3. Mechanically fasten glazing in place until structural sealant is cured.

4. Remove excess sealant from component surfaces before sealant has cured.

H. Install secondary-sealant weatherseal according to sealant manufacturer's written instructions to provide weatherproof joints. Install joint fillers behind sealant as recommended by sealant manufacturer.

I. Install perimeter sealant to comply with requirements of Division 7 Section "Joint Sealants," unless otherwise indicated.

J. Erection Tolerances: Install entrance and storefront systems to comply with the following maximum tolerances:

1. Variation from Plane: Limit variation from plane or location shown to 1/8 inch in 12 feet; 1/4 inch over total length.

2. Alignment: Where surfaces abut in line, limit offset from true alignment to 1/16 inch.

Where surfaces meet at corners, limit offset from true alignment to 1/32 inch.

3. Diagonal Measurements: Limit difference between diagonal measurements to 1/8 inch.

3.3 ADJUSTING AND CLEANING

A. Adjust doors and hardware to provide tight fit at contact points and weather stripping, smooth operation, and weathertight closure.

B. Remove excess sealant and glazing compounds, and dirt from surfaces.

3.4 PROTECTION

A. Provide final protection and maintain conditions, in a manner acceptable to manufacturer and an installer that will ensure entrance and storefront systems are without damage or deterioration at the time of Substantial Completion.

END OF SECTION 084113

1.1 RELATED DOCUMENTS
1.2 SUMMARY
1.3 SYSTEM DESCRIPTION
1.4 SUBMITTALS
1.5 QUALITY ASSURANCE
1.6 PROJECT CONDITIONS
1.7 WARRANTY
2.1 MANUFACTURERS
2.2 MATERIALS
2.3 COMPONENTS
2.4 HARDWARE
2.5 GLAZING
2.6 FABRICATION
2.7 ALUMINUM FINISHES
1. Color Anodic Finish: AAMA 611, AA-M12C22A42/A44, Class I, 0.7 mill (18 microns) or thicker. Color may not differ more than 5 Delta E, in accordance with ASTM D 523.
2.8 STEEL PRIMING
3.1 EXAMINATION
3.2 INSTALLATION
3.3 ADJUSTING AND CLEANING
3.4 PROTECTION

File details come from the government source that posted it. Updated .