Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
MAY 25, 2018 JPG MAC
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
Dwg. of 164
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
CONSTRUCTION DOCUMENTS 2 SUBMISSION
NATIONAL CEMETERY
OF THE ALLEGHENIES
PHASE III DEVELOPMENT
PACKAGE "A"
935PC2006BID DOCUMENTS
GI100
AREA 6
GRAVESITE YIELD SUMMARY
GENERAL NOTES:
AREA 3
AREA 5
AREA 2
AREA 4
AREA 1
AREA 7
OVERALL SITE DEVELOPMENT PLAN 925PC2006FINAL CONSTRUCTION
DOCUMENTS
FEBRUARY 28, 2020
VACOGilesK Polygon
VACOGilesK Polygon
VACOGilesK Polygon
VACOGilesK Polygon
VACOGilesK Polygon
VACOGilesK Polygon
VACOGilesK Polygon
VACOGilesK Line
VACOGilesK Line
VACOGilesK Text Box Joint sealant missing along curb (estimate 5 joints)
VACOGilesK Line
VACOGilesK Line
VACOGilesK Text Box Joint sealant missing along curb (estimate 8 joints)
VACOGilesK Line
VACOGilesK Text Box Some joints are missing joint sealant or joint sealant is separating/incomplete and needs replaced (estimate 7-9 joints)
VACOGilesK Line
VACOGilesK Text Box Replace joint sealant between back of curb and FWS (estimate 10 LF)
VACOGilesK Text Box Some curb joints are separating/incomplete or have metal stakes embedded that need removed and joint sealant replaced (estimate 23-28 joints)
VACOGilesK Line
VACOGilesK Text Box Joint between back of curb and new sidewalk is separating and needs replaced (estimate 30 LF)
VACOGilesK Line
VACOGilesK Text Box Replace joint sealant between back of curb and FWS (estimate 10 LF)
VACOGilesK Line
VACOGilesK Text Box Replace joint sealant between back of curb and FWS (estimate 10 LF)
VACOGilesK Line
VACOGilesK Line
VACOGilesK Line
VACOGilesK Line
VACOGilesK Line
VACOGilesK Text Box Replace 2 joints at sidewalk (estimate 20 LF)
VACOGilesK Line
VACOGilesK Line
VACOGilesK Text Box Replace selected joints at existing columbarium [see next page] (estimate 55 LF)
Wall: 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
A B C D E F G H I J K L
115 114 103 102 91 90 79 78 67 66 55 54 43 42 31 30 19 18 7 6
116 113 104 101 92 89 80 77 68 65 56 53 44 41 32 29 20 17 8 5
117 112 105 100 93 88 81 76 69 64 57 52 45 40 33 28 21 16 9 4
118 111 106 99 94 87 82 75 70 63 58 51 46 39 34 27 22 15 10 3
119 110 107 98 95 86 83 74 71 62 59 50 47 38 35 26 23 14 11 2
120 109 108 97 96 85 84 73 72 61 60 49 48 37 36 25 24 13 12 1
N O
P
Q
Replace
Colombarium Wall
M
Bench
Existing Columbarium Concrete Sidewalk
Bench Bench BenchBench
Bench
Bench
Bench
Bench
GRASS GRASSGRASS GRASS
Bench
Bench
Bench
R R
J & Adjacent Panel Bench pad between Wall 2 & 3 42 66 C
Joint Sealant to be replaced
| Jt Sealant Replacement Areas.pdf |
| Existing columbarium concrete sidewalk replacement & Jt Sealant Replacement.pdf |
| Sheet1 |