23 j Mechl DWGs 10of12sp.pdf

PDF 17 MB Posted

Attached to
Y1DA--LTSCI VA Dallas 549-820B Long Term Spinal Cord Injury
Solicitation number
36C10F22R0045
Issued by

About this file

This document provides details on a federal solicitation and related technical drawings. Solicitation number 36C10F22R0045 from the Department of Veterans Affairs Office of Construction and Facilities Management seeks proposals for the Y1DA--LTSCI VA Dallas 549-820B Long Term Spinal Cord Injury opportunity. The opportunity involves providing long term spinal cord injury care services at facility 549-820B. The related technical drawings file 23 j Mechl DWGs 10of12sp.pdf contains diagrams and specifications but no other descriptive information. The solicitation appears to be open with no stated deadline, pricing, or award date provided in the available information.

View the file

Other files

File Type Posted
Part II of II RFI Response.pdf PDF
01 45 00 chart.pdf PDF
36C10F22R0045 0013.docx DOCX document
RE trailer plan REV.pdf PDF
sign IN-01.33.pdf PDF
RE Field Office REV.pdf PDF
ADD-02 SPECs.pdf PDF
ADD-02 DWGs.pdf PDF
36C10F22R0045 0012.docx DOCX document
LTSCI ADDDENDUM 01drawings RV.pdf PDF
36C10F22R0045 0011.docx DOCX document
Bldg 74 ACM Survey Report.pdf PDF
36C10F22R0045 0010.docx DOCX document
36C10F22R0045 0009.docx DOCX document
36C10F22R0045 0008.docx DOCX document
83-GL-101 VA-Attachment RFI.pdf PDF
36C10F22R0045 0007.docx DOCX document
36C10F22R0045 0006.docx DOCX document
36C10F22R0045 0005.docx DOCX document
1 17 RESIDENT ENGINEER FIeld Office.pdf PDF
LTSCI Pre-proposal visit Sign In Sheets.pdf PDF
1 17 RESIDENT ENGINEER RE FIeld Office.pdf PDF
36C10F22R0045 0004.docx DOCX document
36C10F22R0045 0003.docx DOCX document
36C10F22R0045 0002.docx DOCX document
36C10F22R0045 0001.docx DOCX document
23 b Mechl DWGs 2of12sp.pdf PDF
01_a Civil DWGs 1of4 tt1.pdf PDF
01_d Civil DWGs 4of4 oc.pdf PDF
23 d Mechl DWGs 4of12sp.pdf PDF
04 IRRIGATION DWGs 1of1.pdf PDF
22 a Plmbg DWGs 1of8 tt.pdf PDF
27_a TELECOM DWGs 1of1sp.pdf PDF
26_g Elecl DWGs 7of7g.pdf PDF
20_GENERAL Vol 3 DWGs tt.pdf PDF
LTSCI ProjMan VOL 01 part 1of2 div00-div08 tt1.pdf PDF
26_d Elecl DWGs 4of7sp.pdf PDF
09_f Archl DWGs 6of12sp.pdf PDF
08.0 a Structl DWGs 1of4 tt1.pdf PDF
LTSCI ProjMan VOL 01 part 2of2 div09-div14 tt.pdf PDF
83 LTSCI MES part 1of6.pdf PDF
09_l Archl DWGs 12of12sp.pdf PDF
23 f Mechl DWGs 6of12sp.pdf PDF
VA LTSCI Bid Pack B Suppl Info part 2of2 g.pdf PDF
09_j Archl DWGs 10of12sp.pdf PDF
09_h Archl DWGs 8of12sp.pdf PDF
22 f Plmbg DWGs 6of8 tt.pdf PDF
26_b Elecl DWGs 2of7 tt.pdf PDF
26_f Elecl DWGs 6of7 tt.pdf PDF
22 c Plmbg DWGs 3of8 tt1.pdf PDF
Show 40 more

Latest 50 of 117 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

DN

DN UP

1 4

E

F

D

A.8 A.8

B.8 B.8

AA

AA

F.3 F.3

16.2

16.2

E.3

1.8

D.5

D.5

1.5

A.9 A.9

1.9

E.2

D.6

SHEET NOTES

D A

T E

S

A

M P

Drawing Title

Approved Project Director:

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

PSP 309070 Revisions Date

ARCHITECT/ENGINEERS: Office of

Construction and Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

FILE NAME

Project Abbreviation

F

E

D

C

B

A

F

IL

E N

A M

E

KEY PLAN

FULLY SPRINKLERED

(NOT TO SCALE)

Page Southerland Page, LLP.

1800 Main Street Suite 123

Dallas, TX 75201 pagethink.com

TEL

FAX

ARCHITECTURE / ENGINEERING / INTERIORS / CONSULTING

Austin / Dallas / Denver / Houston / Washington DC /

International Affiliate Offices

214 522 3900

214 522 4380

DWG

C

U se rs \b k in m a n \D o c u m e n ts

\3 b M

E -S

C I- R -C

E N

T R A L b k in m a n R K W

J .r v t

/3

/2

:3

:1

P

M

C:\Users\bkinman\Documents\309070b3ME-SCI-R18-CENTRAL_bkinmanR4KWJ.rvt

83-MP-102

CONSTRUCTION

VA-LTSCI-D

AB

549-820B

SH

MECHANICAL PIPING - FLOOR PLAN - LEVEL 02 OVERALL

LONG TERM SPINAL CORD INJURY

VA NORTH TEXAS HEALTH CARE SYSTEM

4500 S. LANCASTER RD. DALLAS, TX 75216OFFICE OF CONSTRUCTION AND FACILITIES

MANAGEMENT DIRECTOR , CENTRAL REGION

06 MAY 2021

BID PACKAGE B

SCALE: 1/16" = 1'-0"F6 MECHANICAL PIPING - OVERALL PLAN - LEVEL 02 0' 16' 32'8' 64'

NORTH

PLAN

BF

C

D

G

A

H

E

1. REFER TO DRAWING 83-M-001 FOR HVAC PIPING LEGENDS,

ABBREVIATIONS AND GENERAL NOTES.

2. COORDINATE WORK ON THIS SHEET WITH ALL TRADES. WORK SHOWN

ON THIS SHEET IS INTENDED TO PROVIDE THE OVERALL ENGINEERING

DESIGN CONCEPT AND DOES NOT PROVIDE FOR RELOCATIONS,

OFFSETS, ETC., THAT ARE REQUIRED BY THE COORDINATION OF

TRADES. THESE SHALL BE PROVIDED BY THE CONTRACTOR AT NO

ADDITIONAL COST TO THE CONTRACT.

3. ALL MECHANICAL EQUIPMENT REQUIRING ACCESS THAT IS LOCATED

ABOVE GYP. BOARD OR OTHERWISE INACCESSIBLE CEILING SHALL BE

PROVIDED WITH A CEILING ACCESS PANEL SUPPLIED AND INSTALLED BY

THE GENERAL CONTRACTOR. THE MECHANICAL CONTRACTOR SHALL

COORDINATE THE EXACT LOCATION OF THESE ACCESS PANELS WITH

THE GENERAL CONTRACTOR.

4. ISOLATION VALVES SHALL BE PROVIDED IN ALL BRANCH PIPING AND AT

EQUIPMENT CONNECTIONS.

5. INSTALL PIPING TO ALLOW FOR EXPANSION AND CONTRACTION

WITHOUT STRESSING PIPE OR EQUIPMENT CONNECTED.

6. IDENTIFY EACH PIPE WITH LABELING AS REQUIRED BY SPECIFICATIONS.

7. ALL PIPE RUN-OUTS TO INDIVIDUAL VAV TERMINAL UNITS SHALL BE 3/4"

UNLESS NOTED OTHERWISE.

8. ALL VAV TERMINAL UNITS SHALL HAVE TWO-WAY CONTROL VALVES

UNLESS NOTED OTHERWISE.

9. ALL LOW PRESSURE RETURN (LPR) TO BE SLOPED TO 1/8"/LF

10 REFER TO SHEET 83-M-614 FOR THE CHILLED WATER RISER DIAGRAM.

11 REFER TO SHEET 83-M-615 FOR THE HEATING WATER RISER DIAGRAM.

12 REFER TO SHEET 83-M-616 FOR THE STEAM/CONDENSATE RISER

DIAGRAM.

SP

F1

83-M-304

B4

83-M-305

B5

83-M-304

1 1/4"

D

B.8 B.8

F.3

F.3

E.3

1.51.9

E.2

D.6

2 1/2"

83-TU-4-60

83-CRC-06

83-TU-1-40

83-TU-1-44

83-TU-1-49

83-TU-1-45

83-TU-1-55

83-TU-1-51

83-TU-1-42

83-TU-4-59

83-TU-1-53

83-TU-1-43

83-TU-1-47

83-TU-1-46

83-TU-1-48

83-TU-1-52

83-TU-1-50

83-TU-1-39

83-TU-1-54

83-TU-4-62

83-TU-4-64

83-TU-4-61

83-TU-4-65

HWR

CHS

CHR

1 1/4"

H W

S

H W

R

1"1"

2"

2"

C H

S C

H R

83-TU-4-63

H W

S

HWS

83-TU-1-41

HWR

CHS

CHR

3"

3"

1 1/2"

1 1/2"

CHS

LPR

1 1/4"

1 1/4"

3/4"

1 1/2"

1 1/4"

3/4"

LPR

LPR

L P

R

L P

R

LPR

LPR

1"

2 1/2"

1"

1"

2"

1"

1 1/2"

2 1/2"2 1/2"

1 1/4" 1 1/4"

HWS HWR

HWS

H W

R

1"

1"

2 1/2"

2"

2"

L P

R

9' - 8"

13' - 10"

L P

R

13' - 11" 14' - 6"

12' - 5"

13' - 8"

11' - 8"

LPR

C H

R C

H S

H W

R H

W S

L P

R

1 1/2" 1"1 1/4"

1 1/4"

3/4"

2 1/2"

2 1/2"1 1/4"

1 1/4"

2"

2 1/2"

1"

1"

1 1/2"

1 1/4"

3/4" 3/4"

1"

1"

3/4"

3/4"

1"

3" 3"

1" 1"

1" 1"

1 1/2"

H W

R

H W

S

L P

R

LPR

HWS

HWS

CHS CHR

H W

R

H W

S

2"

D D

1" CONDENSATE

DOWN

CONNECT 1" CHS/R

1" HWS/R AND 1"

CONDENSATE TO

CRAC UNIT

MATCHLINE

SEE /F6 83-MP-102F

MATCHLINE

SEE

M A

T C

H

LI

N E

S E

E

F

83-M P

-102B

1" LPR UP TO PENTHOUSE.

REFER TO RISER DIAGRAM.

1" LPR UP TO PENTHOUSE.

REFER TO RISER DIAGRAM.

2" LPR UP TO PENTHOUSE.

REFER TO RISER DIAGRAM.

LPR DOWN THROUGH CHASE.

1" LPR UP TO PENTHOUSE.

REFER TO RISER DIAGRAM.

1-1/2 " LPR DOWN TO LEVEL B2.

REFER TO RISER DIAGRAM.

1-1/4 " LPR UP TO

PENTHOUSE.

REFER TO RISER

DIAGRAM.

1-1/2 " LPR DOWN TO

LEVEL B2. REFER TO

RISER DIAGRAM.

3/4" LPR UP TO

PENTHOUSE.

REFER TO RISER

DIAGRAM.

ISOLATION VALVES FOR

BRANCH PIPING SERVING

MULTIPLE TERMINALS (TYPICAL)

1"

SLOPE

S

LO

P E

CONFERENCE

CLASSROOM

2A026

CLERICAL

CUBICLE

2A019

CLERICAL

CUBICLE

2A022

MED. REC. |

QA

2A006

OFFICE AO

2A025

OFFICE MDS

COORDINATOR

2A015

OFFICE ASST

AO

2A024

OFFICE

PHYSICIAN

2A016

OFFICE

PHYSICIAN

2A018

OFFICE

PHYSICIAN

2A017

NURSE

EDUCATOR

2A023

MED

DIRECTOR

2A021

CHIEF OF

SERVICE

2A020

NURSE

ADMINISTRATOR

2A010

NURSE

ADMINISTRATOR

2A011

SECRETARY |

WAITING

2A029

STAFF

LOUNGE

2A014

CONFERENCE

CLASSROOM

2A027

ELEC

2A005

TELE COMM

2A009

SHARED

OFFICE, QA

CARE COOR

2A028

NURSE

ADMINISTRATOR

2A008

PUBLIC

ELEVATOR

LOBBY

2A001

SERVICE

ELEVATOR

LOBBY

2A004

MECH CHASE

N|A

STAFF TLT

2A013

EXIT STAIR

(1)

2A003

PUBLIC

ELEVATOR

CAB (P1)

B1A009B

SERVICE

ELEVATOR

CAB (S3)

B1A010B

RESIDENT

ELEVATOR

CAB (P6)

1B001B

OFFICE

CORRIDOR

2A030

PUBLIC

CONNECTOR

2A032

OFFICE

CORRIDOR

2A031

SECURITY

2A007

HAC

2A012

RESIDENT

ELEVATOR

CAB (P5)

1B001A

SERVICE

ELEVATOR

CAB (S4)

B1A010A

PUBLIC

ELEVATOR

CAB (P2)

B1A009A

STORAGE SCI

HOME CARE

2F005 OFFICE

HOME CARE

COORD.

2F009

FEMALE

PUBLIC

TOILETS

2F006

MALE PUBLIC

TOILETS

2F007

MECH CHASE

N|A

PUBLIC

LOBBY

2A002

PUBLIC

CONNECTOR

2A032

PUBLIC

CONNECTOR

2A032

SHEET NOTES

D A

A M

P

Drawing Title

Approved Project Director:

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

PSP 309070 Revisions Date

ARCHITECT/ENGINEERS: Office of

Construction and Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

FILE NAME

Project Abbreviation

F

E

D

C

B

A

F

IL

E N

A M

E

KEY PLAN

FULLY SPRINKLERED

(NOT TO SCALE)

Page Southerland Page, LLP.

1800 Main Street Suite 123

Dallas, TX 75201 pagethink.com

TEL

FAX

ARCHITECTURE / ENGINEERING / INTERIORS / CONSULTING

Austin / Dallas / Denver / Houston / Washington DC /

International Affiliate Offices

214 522 3900

214 522 4380

DWG

W

V A -L

T S C

IF

-D \3

B M

E -S

C I- R -b k in m a n .R

V T

/3

/2

:5 :0

A

M

W:\VA-LTSCIF-D\309070B3ME-SCI-R18-bkinman.RVT

83-MP-102A

CONSTRUCTION

VA-LTSCI-D

AB

549-820B

SH

MECHANICAL PIPING - FLOOR PLAN - LEVEL 02 AREA A

LONG TERM SPINAL CORD INJURY

VA NORTH TEXAS HEALTH CARE SYSTEM

4500 S. LANCASTER RD. DALLAS, TX 75216OFFICE OF CONSTRUCTION AND FACILITIES

MANAGEMENT DIRECTOR , CENTRAL REGION

06 MAY 2021

BID PACKAGE B

SCALE: 1/8" = 1'-0"F6 MECHANICAL PIPING - FLOOR PLAN - LEVEL 02 AREA A

0' 16' 32'8' 64'

NORTH

PLAN

BF

C

D

G

A

H

E

1. REFER TO DRAWING 83-M-001 FOR HVAC PIPING LEGENDS,

ABBREVIATIONS AND GENERAL NOTES.

2. COORDINATE WORK ON THIS SHEET WITH ALL TRADES. WORK SHOWN

ON THIS SHEET IS INTENDED TO PROVIDE THE OVERALL ENGINEERING

DESIGN CONCEPT AND DOES NOT PROVIDE FOR RELOCATIONS,

OFFSETS, ETC., THAT ARE REQUIRED BY THE COORDINATION OF

TRADES. THESE SHALL BE PROVIDED BY THE CONTRACTOR AT NO

ADDITIONAL COST TO THE CONTRACT.

3. ALL MECHANICAL EQUIPMENT REQUIRING ACCESS THAT IS LOCATED

ABOVE GYP. BOARD OR OTHERWISE INACCESSIBLE CEILING SHALL BE

PROVIDED WITH A CEILING ACCESS PANEL SUPPLIED AND INSTALLED BY

THE GENERAL CONTRACTOR. THE MECHANICAL CONTRACTOR SHALL

COORDINATE THE EXACT LOCATION OF THESE ACCESS PANELS WITH

THE GENERAL CONTRACTOR.

4. ISOLATION VALVES SHALL BE PROVIDED IN ALL BRANCH PIPING AND AT

EQUIPMENT CONNECTIONS.

5. INSTALL PIPING TO ALLOW FOR EXPANSION AND CONTRACTION

WITHOUT STRESSING PIPE OR EQUIPMENT CONNECTED.

6. IDENTIFY EACH PIPE WITH LABELING AS REQUIRED BY SPECIFICATIONS.

7. ALL PIPE RUN-OUTS TO INDIVIDUAL VAV TERMINAL UNITS SHALL BE 3/4"

UNLESS NOTED OTHERWISE.

8. ALL VAV TERMINAL UNITS SHALL HAVE TWO-WAY CONTROL VALVES

UNLESS NOTED OTHERWISE.

9. ALL LOW PRESSURE RETURN (LPR) TO BE SLOPED TO 1/8"/LF

10 REFER TO SHEET 83-M-614 FOR THE CHILLED WATER RISER DIAGRAM.

11 REFER TO SHEET 83-M-615 FOR THE HEATING WATER RISER DIAGRAM.

12 REFER TO SHEET 83-M-616 FOR THE STEAM/CONDENSATE RISER

DIAGRAM.

bkinman Snapshot

DN

SP

ELEC CLOSET

2B004

THERAPIST (7)

2B015

ELEC

2B018

THERAPIST (1)

2B008

ON CALL TLT

2B005

D1

83-M-305

E

F

D

16.2

83-TU-3-36

83-TU-3-37

83-TU-3-34

83-TU-3-32

83-TU-3-33

83-TU-3-40

83-TU-2-34

83-CRC-07

83-TU-2-36

83-TU-2-37

83-TU-3-38

83-TU-3-39

83-TU-3-35

3"

3"

2"

1"

1"

1"

1"

ON CALL

2B007

OCCUPATIONAL

THERAPY

2B021

THERAPIST (2)

2B009

C H R

C H S H W

R

H W

S 2"

3"

3"

2"

83-TU-2-35

83-TU-2-31

83-TU-2-32

83-TU-2-33

3"

3"

1 1/2"

1 1/2"

CHS CHR

2"

1"

LPR

LPR

LPR

L P

R

2" 2"

3"

3"

3" 3"

PUBLIC

CONNECTOR

2B025

2"

HW

S HW

R

14' - 3"

13' - 10"

LP

R

14' - 9"

13' - 10"

LP

R

C H

RC

H S

C H R

C H S

H W

R

H W

S

CHR

CHS

HW

R

HW

S

LP

R

HW

S HW

R CHS

CHR

1 1/2"

1 1/2"

1"

1"

1"

2"

2"

1"

2"

2"

2"

1"

1"

1 1/2"

2 1/2"

1"

2 1/2"

D

1"

1" CONDENSATE

INTO TAIL PIECE

OF SINK

4" LPS

4" VENT UP

6" VENT UP

M A

T C

H L

IN

E

S E

E

F

3-

M P

-1

2A 1" LPR UP TO PENTHOUSE.

REFER TO RISER DIAGRAM.

1" LPR UP TO PENTHOUSE

REFER TO RISER DIAGRAM

1-1/2" LPR UP TO

PENTHOUSE. REFER TO

RISER DIAGRAM.

83-FCU-16

1"1"

1"

D

C H

R

C H

S

ROUTE 1" CONDENSATE

DRAIN TO TAIL PIECE

OF SINK.

CH

R

1" LPR UP TO PENTHOUSE.

REFER TO RISER DIAGRAM.

2-1/2" LPR DOWN TO

LEVEL B2. REFER TO

RISER DIAGRAM

SLOPE

SHEET NOTES

D A

A

M P

Drawing Title

Approved Project Director:

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

PSP 309070 Revisions Date

ARCHITECT/ENGINEERS: Office of

Construction and Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

FILE NAME

Project Abbreviation

F

E

D

C

B

A

F

IL

E N

A M

E

KEY PLAN

FULLY SPRINKLERED

(NOT TO SCALE)

Page Southerland Page, LLP.

1800 Main Street Suite 123

Dallas, TX 75201 pagethink.com

TEL

FAX

ARCHITECTURE / ENGINEERING / INTERIORS / CONSULTING

Austin / Dallas / Denver / Houston / Washington DC /

International Affiliate Offices

214 522 3900

214 522 4380

DWG

C

U se rs \b k in m a n \D o c u m e n ts

\3 b M

E -S

C I- R -C

E N

T R A L b k in m a n R K W

J .r v t

/3

/2

:3

:2

P

M

C:\Users\bkinman\Documents\309070b3ME-SCI-R18-CENTRAL_bkinmanR4KWJ.rvt

83-MP-102B

CONSTRUCTION

VA-LTSCI-D

AB

549-820B

SH

MECHANICAL PIPING - FLOOR PLAN - LEVEL 02 AREA B

LONG TERM SPINAL CORD INJURY

VA NORTH TEXAS HEALTH CARE SYSTEM

4500 S. LANCASTER RD. DALLAS, TX 75216OFFICE OF CONSTRUCTION AND FACILITIES

MANAGEMENT DIRECTOR , CENTRAL REGION

06 MAY 2021

BID PACKAGE B

SCALE: 1/8" = 1'-0"F6 MECHANICAL PIPING - FLOOR PLAN - LEVEL 02 AREA B 0' 16' 32'8' 64'

NORTH

PLAN

BF

C

D

G

A

H

E

1. REFER TO DRAWING 83-M-001 FOR HVAC PIPING LEGENDS,

ABBREVIATIONS AND GENERAL NOTES.

2. COORDINATE WORK ON THIS SHEET WITH ALL TRADES. WORK SHOWN

ON THIS SHEET IS INTENDED TO PROVIDE THE OVERALL ENGINEERING

DESIGN CONCEPT AND DOES NOT PROVIDE FOR RELOCATIONS,

OFFSETS, ETC., THAT ARE REQUIRED BY THE COORDINATION OF

TRADES. THESE SHALL BE PROVIDED BY THE CONTRACTOR AT NO

ADDITIONAL COST TO THE CONTRACT.

3. ALL MECHANICAL EQUIPMENT REQUIRING ACCESS THAT IS LOCATED

ABOVE GYP. BOARD OR OTHERWISE INACCESSIBLE CEILING SHALL BE

PROVIDED WITH A CEILING ACCESS PANEL SUPPLIED AND INSTALLED BY

THE GENERAL CONTRACTOR. THE MECHANICAL CONTRACTOR SHALL

COORDINATE THE EXACT LOCATION OF THESE ACCESS PANELS WITH

THE GENERAL CONTRACTOR.

4. ISOLATION VALVES SHALL BE PROVIDED IN ALL BRANCH PIPING AND AT

EQUIPMENT CONNECTIONS.

5. INSTALL PIPING TO ALLOW FOR EXPANSION AND CONTRACTION

WITHOUT STRESSING PIPE OR EQUIPMENT CONNECTED.

6. IDENTIFY EACH PIPE WITH LABELING AS REQUIRED BY SPECIFICATIONS.

7. ALL PIPE RUN-OUTS TO INDIVIDUAL VAV TERMINAL UNITS SHALL BE 3/4"

UNLESS NOTED OTHERWISE.

8. ALL VAV TERMINAL UNITS SHALL HAVE TWO-WAY CONTROL VALVES

UNLESS NOTED OTHERWISE.

9. ALL LOW PRESSURE RETURN (LPR) TO BE SLOPED TO 1/8"/LF

10 REFER TO SHEET 83-M-614 FOR THE CHILLED WATER RISER DIAGRAM.

11 REFER TO SHEET 83-M-615 FOR THE HEATING WATER RISER DIAGRAM.

F4

83-M-301

B5

83-M-304

1 3

A.8

A.9

83-TU-4-60

83-TU-4-59

83-TU-4-61

83-TU-4-50

83-TU-4-56

83-TU-4-53

83-TU-4-55

83-TU-4-58

83-TU-4-52

83-TU-4-57

83-TU-4-54

3/4"

3/4"

2"

2"

1"

1"

H W

R

1 1/2"

H W

S

HWS

HWR

HWR

HWS

1 1/2"

L P

R

LPR

1 1/2"

1"

1 1/4"

83-TU-4-49

2"

2"

1 1/4"

1 1/4"

9' - 8"

13' - 11"

11' - 8"

LPR

LPR

H W

R H

W S

L P

R

1 1/2" 1"

3/4"

1 1/2"

1"

1"

1"

1"

1 1/2"

1 1/2"

2"

2"

MATCHLINE

SEE /F6 83-MP-102A

PROVIDE 3-WAY

VALVE

1-1/4 " LPR UP TO

PENTHOUSE.

REFER TO RISER

DIAGRAM.

1 " LPR UP TO PENTHOUSE.

REFER TO RISER DIAGRAM.

1-1/2 " LPR DOWN TO

LEVEL B2. REFER TO

RISER DIAGRAM.

S

LO

P E

OFFICE

HOME CARE

COORD.

2F013

OFFICE

HOME CARE

COORD.

2F012

OFFICE

HOME CARE

COORD.

2F011

STORAGE SCI

HOME CARE

2F005 OFFICE

HOME CARE

COORD.

2F009

OFFICE

HOME CARE

COORD.

2F010

FEMALE

PUBLIC

TOILETS

2F006

MALE PUBLIC

TOILETS

2F007

MECH CHASE

N|A

PUBLIC

LOBBY

2A002

INTERVIEW

RM.

2F203

OFFICE

HOME CARE

COORD.

2F202

OFFICE

TELEHEALTH

2F201

OFFICE

HOME CARE

COORD.

2F200

OFFICE

PHYSICIAN

2F199

ELEC

2F198

OFFICE

CORRIDOR

2F197

EXIT STAIR

(9)

1F021

SHEET NOTES

D A

A M

P

Drawing Title

Approved Project Director:

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

PSP 309070 Revisions Date

ARCHITECT/ENGINEERS: Office of

Construction and Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

FILE NAME

Project Abbreviation

F

E

D

C

B

A

F

IL

E N

A M

E

KEY PLAN

FULLY SPRINKLERED

(NOT TO SCALE)

Page Southerland Page, LLP.

1800 Main Street Suite 123

Dallas, TX 75201 pagethink.com

TEL

FAX

ARCHITECTURE / ENGINEERING / INTERIORS / CONSULTING

Austin / Dallas / Denver / Houston / Washington DC /

International Affiliate Offices

214 522 3900

214 522 4380

DWG

W

V A -L

T S C

IF

-D \3

B M

E -S

C I- R -b k in m a n .R

V T

/3

/2

:5 :1

A

M

W:\VA-LTSCIF-D\309070B3ME-SCI-R18-bkinman.RVT

83-MP-102F

CONSTRUCTION

VA-LTSCI-D

AB

549-820B

SH

MECHANICAL PIPING - FLOOR PLAN - LEVEL 02 AREA F

LONG TERM SPINAL CORD INJURY

VA NORTH TEXAS HEALTH CARE SYSTEM

4500 S. LANCASTER RD. DALLAS, TX 75216OFFICE OF CONSTRUCTION AND FACILITIES

MANAGEMENT DIRECTOR , CENTRAL REGION

06 MAY 2021

BID PACKAGE B

SCALE: 1/8" = 1'-0"F6 MECHANICAL PIPING - FLOOR PLAN - LEVEL 02 AREA F

0' 16' 32'8' 64'

NORTH

PLAN

BF

C

D

G

A

H

E

1. REFER TO DRAWING 83-M-001 FOR HVAC PIPING LEGENDS,

ABBREVIATIONS AND GENERAL NOTES.

2. COORDINATE WORK ON THIS SHEET WITH ALL TRADES. WORK SHOWN

ON THIS SHEET IS INTENDED TO PROVIDE THE OVERALL ENGINEERING

DESIGN CONCEPT AND DOES NOT PROVIDE FOR RELOCATIONS,

OFFSETS, ETC., THAT ARE REQUIRED BY THE COORDINATION OF

TRADES. THESE SHALL BE PROVIDED BY THE CONTRACTOR AT NO

ADDITIONAL COST TO THE CONTRACT.

3. ALL MECHANICAL EQUIPMENT REQUIRING ACCESS THAT IS LOCATED

ABOVE GYP. BOARD OR OTHERWISE INACCESSIBLE CEILING SHALL BE

PROVIDED WITH A CEILING ACCESS PANEL SUPPLIED AND INSTALLED BY

THE GENERAL CONTRACTOR. THE MECHANICAL CONTRACTOR SHALL

COORDINATE THE EXACT LOCATION OF THESE ACCESS PANELS WITH

THE GENERAL CONTRACTOR.

4. ISOLATION VALVES SHALL BE PROVIDED IN ALL BRANCH PIPING AND AT

EQUIPMENT CONNECTIONS.

5. INSTALL PIPING TO ALLOW FOR EXPANSION AND CONTRACTION

WITHOUT STRESSING PIPE OR EQUIPMENT CONNECTED.

6. IDENTIFY EACH PIPE WITH LABELING AS REQUIRED BY SPECIFICATIONS.

7. ALL PIPE RUN-OUTS TO INDIVIDUAL VAV TERMINAL UNITS SHALL BE 3/4"

UNLESS NOTED OTHERWISE.

8. ALL VAV TERMINAL UNITS SHALL HAVE TWO-WAY CONTROL VALVES

UNLESS NOTED OTHERWISE.

9. ALL LOW PRESSURE RETURN (LPR) TO BE SLOPED TO 1/8"/LF

10 REFER TO SHEET 83-M-614 FOR THE CHILLED WATER RISER DIAGRAM.

11 REFER TO SHEET 83-M-615 FOR THE HEATING WATER RISER DIAGRAM.

12 REFER TO SHEET 83-M-616 FOR THE STEAM/CONDENSATE RISER

DIAGRAM.

DN

UP

UP

DN

DN

1 4

E

F

F

D

A.8 A.8

B.8 B.8

F.3

16.2

16.2

E.3

D.5

D.5

A.9 A.9

E.2 E.2

D.6

SHEET NOTES

D A

A

M P

Drawing Title

Approved Project Director:

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

PSP 309070 Revisions Date

ARCHITECT/ENGINEERS: Office of

Construction and Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

FILE NAME

Project Abbreviation

F

E

D

C

B

A

F

IL

E N

A M

E

KEY PLAN

FULLY SPRINKLERED

(NOT TO SCALE)

Page Southerland Page, LLP.

1800 Main Street Suite 123

Dallas, TX 75201 pagethink.com

TEL

FAX

ARCHITECTURE / ENGINEERING / INTERIORS / CONSULTING

Austin / Dallas / Denver / Houston / Washington DC /

International Affiliate Offices

214 522 3900

214 522 4380

DWG

C

U se rs \b k in m a n \D o c u m e n ts

\3 b M

E -S

C I- R -C

E N

T R A L b k in m a n R K W

J .r v t

/3

/2

:3

:3

P

M

C:\Users\bkinman\Documents\309070b3ME-SCI-R18-CENTRAL_bkinmanR4KWJ.rvt

83-MP-103

CONSTRUCTION

VA-LTSCI-D

AB

549-820B

SH

MECHANICAL PIPING - FLOOR PLAN - PENTHOUSE

OVERALL

LONG TERM SPINAL CORD INJURY

VA NORTH TEXAS HEALTH CARE SYSTEM

4500 S. LANCASTER RD. DALLAS, TX 75216OFFICE OF CONSTRUCTION AND FACILITIES

MANAGEMENT DIRECTOR , CENTRAL REGION

06 MAY 2021

BID PACKAGE B

SCALE: 1/16" = 1'-0"F6 MECHANICAL PIPING - OVERALL PLAN - PENTHOUSE 0' 16' 32'8' 64'

NORTH

PLAN

BF

C

D

G

A

H

E

1. REFER TO DRAWING 83-M-001 FOR HVAC PIPING LEGENDS,

ABBREVIATIONS AND GENERAL NOTES.

2. COORDINATE WORK ON THIS SHEET WITH ALL TRADES. WORK SHOWN

ON THIS SHEET IS INTENDED TO PROVIDE THE OVERALL ENGINEERING

DESIGN CONCEPT AND DOES NOT PROVIDE FOR RELOCATIONS,

OFFSETS, ETC., THAT ARE REQUIRED BY THE COORDINATION OF

TRADES. THESE SHALL BE PROVIDED BY THE CONTRACTOR AT NO

ADDITIONAL COST TO THE CONTRACT.

3. ALL MECHANICAL EQUIPMENT REQUIRING ACCESS THAT IS LOCATED

ABOVE GYP. BOARD OR OTHERWISE INACCESSIBLE CEILING SHALL BE

PROVIDED WITH A CEILING ACCESS PANEL SUPPLIED AND INSTALLED BY

THE GENERAL CONTRACTOR. THE MECHANICAL CONTRACTOR SHALL

COORDINATE THE EXACT LOCATION OF THESE ACCESS PANELS WITH

THE GENERAL CONTRACTOR.

4. ISOLATION VALVES SHALL BE PROVIDED IN ALL BRANCH PIPING AND AT

EQUIPMENT CONNECTIONS.

5. INSTALL PIPING TO ALLOW FOR EXPANSION AND CONTRACTION

WITHOUT STRESSING PIPE OR EQUIPMENT CONNECTED.

6. IDENTIFY EACH PIPE WITH LABELING AS REQUIRED BY SPECIFICATIONS.

7. ALL PIPE RUN-OUTS TO INDIVIDUAL VAV TERMINAL UNITS SHALL BE 3/4"

UNLESS NOTED OTHERWISE.

8. ALL VAV TERMINAL UNITS SHALL HAVE TWO-WAY CONTROL VALVES

UNLESS NOTED OTHERWISE.

9. ALL LOW PRESSURE RETURN (LPR) TO BE SLOPED TO 1/8"/LF

10 REFER TO SHEET 83-M-614 FOR THE CHILLED WATER RISER DIAGRAM.

11 REFER TO SHEET 83-M-615 FOR THE HEATING WATER RISER DIAGRAM.

UP

DN

DN

F4

83-M-301

F3

83-M-302

2 1/2"

2 1/2"

4"

4"

E

E

D

B.8 B.8

F.3

F.3

E.3

1.51.9

E.2

D.6

83-ARU-01

83-FCU-21

83-ERU-03

83-RF-01

83-ERU-02

83-FCU-19

83-FCU-20

83-FCU-18B

6"

C H

S

HWS

HWR

C H

S

C H

S

C H

R

HWS

CHS

8"

4"

1 1/4"

3/4"

3/4"

2"

L P

S

2 1/2"

H W

S

2 1/2"

H W

R

1 1/4"

83-FCU-24

STEAM PREHEAT

COIL 83-PHC-02

4"

C H

R

4"

C H

S

2 1/2"

H W

R

H W

S

6" 6"

3"3"

CHR

CHS

6"

6"

C H

R

2"

H W

S

3"

C H

R

4"

H W

S

3/4"

H W

R

3/4"

1 1/4"

1 1/4"

3"

3" 6" 6"

4" 4"

C H

S

4"

C H

R

4"

H W

S

2 1/2"

H W

R

2 1/2"

4"

4"

3"

2"

2"

LPS

83-H-B01

83-H-05

83-AHU-05

83-H-01

LPS

83-ARU-02

H W

R

4"

4"

HWS

6"

HWR

6"

4" 4"

LPSLPS

L P

S

LPS

HWR

4"

8"8"

2"

2"

1" 1"

3/4"

3/4"

1 1/2"

3/4"

2"

2"

3/4"

2" 2" 3"

3"

4" 3"

CHR

CHS

HWR

HWS

L P

S

CHS

CHR

LPS

4"

1 1/4"

2 1/2"

1 1/4"

6"

2 1/2"

2 1/2" 4"4"

HWR

HWS

CHR CHS

4"

3"

1 1/4" 1 1/4"

L P

R

1 1/4"

DD

D D

1"

1"

1 1/4"

1 1/2"

1"

1 1/4"

1 1/2"

D

1 1/2" CONDENSATE

DOWN TO FLOOR

DRAIN

1 1/4" FUTURE STEAM

LINE CAPPED FOR FUTURE

83-H-B01

83-PHC-03

1 1/4"

1 1/4"

2" 2" 1"

1"

83-DOAU-01

ROUTE CONDENSATE

DRAINS TO FLOOR SINK.

83-AHU-01

MATCHLINE

SEE /F6 83-MP-103F

M A

T C

H

LI

N E

S E

E

F

-M

P -1

B

1-1/4" LPR DOWN

TO LEVEL 2

ELEC.

3A004

ELEVATOR

MACHINE

ROOM

3B001

EXIT STAIR

(1)

3A003

ELEVATOR

MACHINE

ROOM

3A001

MECHANICAL

PENTHOUSE

3A002

PUBLIC

ELEVATOR

CAB (P1)

B1A009B

SERVICE

ELEVATOR

CAB (S3)

B1A010B

RESIDENT

ELEVATOR

CAB (P6)

1B001B

SERVICE

ELEVATOR

CAB (S4)

B1A010A

PUBLIC

ELEVATOR

CAB (P2)

B1A009A

EXIT STAIR

(1)

VESTIBULE

3A005

SERVICE

ELEVATOR

MACHINE

ROOM

3A006

RESIDENT

ELEVATOR

CAB (P5)

1B001A

MECHANICAL

PENTHOUSE

3A002

SHEET NOTES

KEY NOTES

DESCRIPTIONNUMBER

D A

A M

P

Drawing Title

Approved Project Director:

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

PSP 309070 Revisions Date

ARCHITECT/ENGINEERS: Office of

Construction and Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

FILE NAME

Project Abbreviation

F

E

D

C

B

A

F

IL

E N

A M

E

KEY PLAN

FULLY SPRINKLERED

(NOT TO SCALE)

Page Southerland Page, LLP.

1800 Main Street Suite 123

Dallas, TX 75201 pagethink.com

TEL

FAX

ARCHITECTURE / ENGINEERING / INTERIORS / CONSULTING

Austin / Dallas / Denver / Houston / Washington DC /

International Affiliate Offices

214 522 3900

214 522 4380

DWG

W

V A -L

T S C

IF

-D \3

B M

E -S

C I- R -b k in m a n .R

V T

/3

/2

:0

:5

A

M

W:\VA-LTSCIF-D\309070B3ME-SCI-R18-bkinman.RVT

83-MP-103A

CONSTRUCTION

VA-LTSCI-D

AB

549-820B

SH

MECHANICAL PIPING - FLOOR PLAN - PENTHOUSE AREA A

LONG TERM SPINAL CORD INJURY

VA NORTH TEXAS HEALTH CARE SYSTEM

4500 S. LANCASTER RD. DALLAS, TX 75216OFFICE OF CONSTRUCTION AND FACILITIES

MANAGEMENT DIRECTOR , CENTRAL REGION

06 MAY 2021

BID PACKAGE B

SCALE: 1/8" = 1'-0"F6 MECHANICAL PIPING - FLOOR PLAN - PENTHOUSE AREA A 0' 16' 32'8' 64'

NORTH

PLAN

BF

C

D

G

A

H

E

1 INSTALL STEAM PIPE ANCHOR.

2 INSTALL 4'-2" x 8'-4" EXPANSION LOOP. ON BOTH SIDES OF LOOP, INSTALL PIPE GUIDES 16'-8" FROM CENTER OF LOOP.

3 ROUTE LPR FROM STEAM HUMIDIFIERS AND STEAM PRE-HEAT COILS

DOWN THROUGH FLOORSLAB TO LEVEL 2 CEILING. REFER TO LEVEL 2

PIPING PLANS FOR CONTINUATION, AND 83-M-616 FOR LPR RISER

DIAGRAMS.

4 PROVIDE ISOLATION VALVES IN ALL STEAM, CHILLED, AND HOT WATER

BRANCH PIPE AT POINT OF TAKE-OFF FROM MAINS. IF VALVE ACCESS IS

HINDERED BY DUCTWORK/EQUIPMENT, PROVIDE SECOND SET OF

VALVES, LOCATED WHERE PROPER ACCESS CAN BE HAD. TYPICAL FOR

ALL PENTHOUSE BRANCH PIPING.

5 REFER TO WATER COIL PIPING DETAIL C5/83-M-504.

6 PROVIDE YELLOW AND BLACK DIAGONALLY STRIPED SAFETY TAPE

AROUND THE PERIMETER OF THE HOUSEKEEPING PAD. TAPE SHALL BE

35 MIL WEAR RESISTANT RIGID PVC, SMOOTH SLIP RESISTANT FINISH,

PEEL STRENGTH 14 N / 25MM, TENSILE STRENGTH 80 N / 25 MM. SIMILAR

TO SAFETYTAC HAZARD BY CREATIVE SAFETY SUPPLY OR EQUAL.

1. REFER TO DRAWING 83-M-001 FOR HVAC PIPING LEGENDS,

ABBREVIATIONS AND GENERAL NOTES.

2. COORDINATE WORK ON THIS SHEET WITH ALL TRADES. WORK SHOWN

ON THIS SHEET IS INTENDED TO PROVIDE THE OVERALL ENGINEERING

DESIGN CONCEPT AND DOES NOT PROVIDE FOR RELOCATIONS,

OFFSETS, ETC., THAT ARE REQUIRED BY THE COORDINATION OF

TRADES. THESE SHALL BE PROVIDED BY THE CONTRACTOR AT NO

ADDITIONAL COST TO THE CONTRACT.

3. ALL MECHANICAL EQUIPMENT REQUIRING ACCESS THAT IS LOCATED

ABOVE GYP. BOARD OR OTHERWISE INACCESSIBLE CEILING SHALL BE

PROVIDED WITH A CEILING ACCESS PANEL SUPPLIED AND INSTALLED BY

THE GENERAL CONTRACTOR. THE MECHANICAL CONTRACTOR SHALL

COORDINATE THE EXACT LOCATION OF THESE ACCESS PANELS WITH

THE GENERAL CONTRACTOR.

4. ISOLATION VALVES SHALL BE PROVIDED IN ALL BRANCH PIPING AND AT

EQUIPMENT CONNECTIONS.

5. INSTALL PIPING TO ALLOW FOR EXPANSION AND CONTRACTION

WITHOUT STRESSING PIPE OR EQUIPMENT CONNECTED.

6. IDENTIFY EACH PIPE WITH LABELING AS REQUIRED BY SPECIFICATIONS.

7. ALL PIPE RUN-OUTS TO INDIVIDUAL VAV TERMINAL UNITS SHALL BE 3/4"

UNLESS NOTED OTHERWISE.

8. ALL VAV TERMINAL UNITS SHALL HAVE TWO-WAY CONTROL VALVES

UNLESS NOTED OTHERWISE.

9. ALL LOW PRESSURE RETURN (LPR) TO BE SLOPED TO 1/8"/LF

10 REFER TO SHEET 83-M-614 FOR THE CHILLED WATER RISER DIAGRAM.

11 REFER TO SHEET 83-M-615 FOR THE HEATING WATER RISER DIAGRAM.

12 REFER TO SHEET 83-M-616 FOR THE STEAM/CONDENSATE RISER

DIAGRAM.

E

E

F

F

D

D

83-FCU-21

83-AHU-02

83-AHU-03

83-ERU-01

83-FCU-17B

6" HWS

CHS

8"

4" 4"

2 1/2"

2 1/2"

CHR

CHSHW

R

HW

S

STEAM PREHEAT COIL 83-PHC-01

H W

R

C H

S

C H

R

2 1/2"

4"

83-H-02

4" 2 1/2"

2 1/2" 4"

2"

2"

4"

4"

83-ARU-03

8" 8"

6" 6"

H W

S

83-FCU-25

83-H-03

10"

MECHANICAL

PENTHOUSE

3A002

LPS

HWR

H W

SH

W

R

LPS

H W

S

H W

R

C H S

C H R

LP

S

6"

3/4"

3/4"

3/4"

3/4"

6"

6" 10"

6"

4"

6" 6" 8"

8" 4"

6"

8"

8"

L P

S

2 1/2"

2 1/2"

4"

4"

C H R

C H S

H W

R

H W

S

LPS

ROUTE 1 1/4" CONDENSATE

DOWN TO FLOOR DRAIN

D

D

1 1/4"

ROUTE 1 1/4" CONDENSATE

DOWN TO FLOOR DRAIN

1 1/4"

1" CHS/R, 1 1/4" CONDENSATE

TO FCU-21

DPT

DPT

SPS

ROLL DN

83-DOAU-02

1 1/4"

2"ROUTE 1-1/2"

CONDENSATE DRAIN

TO FLOOR DRAIN.

C H

S

C H

R

2 1/2" 2 1/2"

M A

T C

H

LI

N E

S E

E

F

-M

P -1

A

2 1/2"

2 1/2"

4"

4"

ELEVATOR

MACHINE

ROOM

3B001

RESIDENT

ELEVATOR

CAB (P6)

1B001B

EXIT STAIR

(7)

3B004

ELEC.

3B003

RESIDENT

ELEVATOR

CAB (P5)

1B001A

SHEET NOTES

KEY NOTES

DESCRIPTIONNUMBER

D A

A M

P

Drawing Title

Approved Project Director:

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

PSP 309070 Revisions Date

ARCHITECT/ENGINEERS: Office of

Construction and Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

FILE NAME

Project Abbreviation

F

E

D

C

B

A

F

IL

E N

A M

E

KEY PLAN

FULLY SPRINKLERED

(NOT TO SCALE)

Page Southerland Page, LLP.

1800 Main Street Suite 123

Dallas, TX 75201 pagethink.com

TEL

FAX

ARCHITECTURE / ENGINEERING / INTERIORS / CONSULTING

Austin / Dallas / Denver / Houston / Washington DC /

International Affiliate Offices

214 522 3900

214 522 4380

DWG

C

U se rs \b k in m a n \D o c u m e n ts

\3 b M

E -S

C I- R -C

E N

T R A L b k in m a n R K W

J .r v t

/2

/2

:5 :2

P

M

C:\Users\bkinman\Documents\309070b3ME-SCI-R18-CENTRAL_bkinmanR4KWJ.rvt

83-MP-103B

CONSTRUCTION

VA-LTSCI-D

AB

549-820B

SH

MECHANICAL PIPING - FLOOR PLAN - PENTHOUSE AREA B

LONG TERM SPINAL CORD INJURY

VA NORTH TEXAS HEALTH CARE SYSTEM

4500 S. LANCASTER RD. DALLAS, TX 75216OFFICE OF CONSTRUCTION AND FACILITIES

MANAGEMENT DIRECTOR , CENTRAL REGION

06 MAY 2021

BID PACKAGE B

SCALE: 1/8" = 1'-0"F6 MECHANICAL PIPING - FLOOR PLAN - PENTHOUSE AREA B

0' 16' 32'8' 64'

NORTH

PLAN

BF

C

D

G

A

H

E

1 INSTALL STEAM PIPE ANCHOR.

2 ROUTE LPR FROM STEAM HUMIDIFIERS AND STEAM PRE-HEAT COILS

DOWN THROUGH FLOORSLAB TO LEVEL 2 CEILING. REFER TO LEVEL 2

PIPING PLANS FOR CONTINUATION, AND 83-M-616 FOR LPR RISER

DIAGRAMS.

3 APPROXIMATE LOCATION OF HYDRONIC STATIC PRESSURE SENSOR, (5

PSI ADJ.). COORDINATE EXACT LOCATION WITH TEST AND BALANCE

CONTRACTOR TO ENSURE OPTIMIZED SYSTEM CONTROL.

4 APPROXIMATE LOCATION OF CHILLED AND HOT WATER PRESSURE

DIFFERENTIAL TRANSMITTERS. COORDINATE EXACT LOCATIONS WITH

TEST AND BALANCE CONTRACTOR TO ENSURE OPTIMIZED SYSTEM

CONTROL.

5 PROVIDE ISOLATION VALVES IN ALL STEAM, CHILLED, AND HOT WATER

BRANCH PIPE AT POINT OF TAKE-OFF FROM MAINS. IF VALVE ACCESS

IS HINDERED BY DUCTWORK/EQUIPMENT, PROVIDE SECOND SET OF

VALVES, LOCATED WHERE PROPER ACCESS CAN BE HAD. TYPICAL FOR

ALL PENTHOUSE BRANCH PIPING.

6 REFER TO WATER COIL PIPING DETAIL C5/83-M-504.

7 REFER TO STEAM COIL PIPING DETAIL F6/83-M-505.

8 PROVIDE YELLOW AND BLACK DIAGONALLY STRIPED SAFETY TAPE

AROUND THE PERIMETER OF THE HOUSEKEEPING PAD. TAPE SHALL BE

35 MIL WEAR RESISTANT RIGID PVC, SMOOTH SLIP RESISTANT FINISH,

PEEL STRENGTH 14 N / 25MM, TENSILE STRENGTH 80 N / 25 MM. SIMILAR

TO SAFETYTAC HAZARD BY CREATIVE SAFETY SUPPLY OR EQUAL.

1. REFER TO DRAWING 83-M-001 FOR HVAC PIPING LEGENDS,

ABBREVIATIONS AND GENERAL NOTES.

2. COORDINATE WORK ON THIS SHEET WITH ALL TRADES. WORK SHOWN

ON THIS SHEET IS INTENDED TO PROVIDE THE OVERALL ENGINEERING

DESIGN CONCEPT AND DOES NOT PROVIDE FOR RELOCATIONS,

OFFSETS, ETC., THAT ARE REQUIRED BY THE COORDINATION OF

TRADES. THESE SHALL BE PROVIDED BY THE CONTRACTOR AT NO

ADDITIONAL COST TO THE CONTRACT.

3. ALL MECHANICAL EQUIPMENT REQUIRING ACCESS THAT IS LOCATED

ABOVE GYP. BOARD OR OTHERWISE INACCESSIBLE CEILING SHALL BE

PROVIDED WITH A CEILING ACCESS PANEL SUPPLIED AND INSTALLED BY

THE GENERAL CONTRACTOR. THE MECHANICAL CONTRACTOR SHALL

COORDINATE THE EXACT LOCATION OF THESE ACCESS PANELS WITH

THE GENERAL CONTRACTOR.

4. ISOLATION VALVES SHALL BE PROVIDED IN ALL BRANCH PIPING AND AT

EQUIPMENT CONNECTIONS.

5. INSTALL PIPING TO ALLOW FOR EXPANSION AND CONTRACTION

WITHOUT STRESSING PIPE OR EQUIPMENT CONNECTED.

6. IDENTIFY EACH PIPE WITH LABELING AS REQUIRED BY SPECIFICATIONS.

7. ALL PIPE RUN-OUTS TO INDIVIDUAL VAV TERMINAL UNITS SHALL BE 3/4"

UNLESS NOTED OTHERWISE.

8. ALL VAV TERMINAL UNITS SHALL HAVE TWO-WAY CONTROL VALVES

UNLESS NOTED OTHERWISE.

9. ALL LOW PRESSURE RETURN (LPR) TO BE SLOPED TO 1/8"/LF

10 REFER TO SHEET 83-M-614 FOR THE CHILLED WATER RISER DIAGRAM.

11 REFER TO SHEET 83-M-615 FOR THE HEATING WATER RISER DIAGRAM.

12 REFER TO SHEET 83-M-616 FOR THE STEAM/CONDENSATE RISER

DIAGRAM.

F4

83-M-301

1 3

A.8

B.8

A.9

83-ARU-01

83-AHU-04

83-ERU-03

C H

S

HWS

HWR

4"

L P

S

1 1/4"

3"3"

CHR

CHS

6"

6"

H W

S

3"

C H

R

4"

2"

2"

LPS

83-H-04

H W

R

2"

2"

1" 1"

1 1/4"

4"

4"

3"

3"

4"

3"

3"

3"

4"

4"

L P

R

1 1/4"

STEAM PREHEAT COIL 83-

PHC-03 MOUNTED IN VERTICAL

DUCTWORK

83-PHC-03

MATCHLINE

SEE /F6 83-MP-103A

1-1/4" LPR DOWN

TO LEVEL 2

MECHANICAL

PENTHOUSE

3A002

SHEET NOTES

KEY NOTES

DESCRIPTIONNUMBER

D A

A M

P

Drawing Title

Approved Project Director:

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

PSP 309070 Revisions Date

ARCHITECT/ENGINEERS: Office of

Construction and Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

FILE NAME

Project Abbreviation

F

E

D

C

B

A

F

IL

E N

A M

E

KEY PLAN

FULLY SPRINKLERED

(NOT TO SCALE)

Page Southerland Page, LLP.

1800 Main Street Suite 123

Dallas, TX 75201 pagethink.com

TEL

FAX

ARCHITECTURE / ENGINEERING / INTERIORS / CONSULTING

Austin / Dallas / Denver / Houston / Washington DC /

International Affiliate Offices

214 522 3900

214 522 4380

DWG

W

V A -L

T S C

IF

-D \3

B M

E -S

C I- R -b k in m a n .R

V T

/3

/2

:5 :1

A

M

W:\VA-LTSCIF-D\309070B3ME-SCI-R18-bkinman.RVT

83-MP-103F

CONSTRUCTION

VA-LTSCI-D

AB

549-820B

SH

MECHANICAL PIPING - FLOOR PLAN - PENTHOUSE AREA F

LONG TERM SPINAL CORD INJURY

VA NORTH TEXAS HEALTH CARE SYSTEM

4500 S. LANCASTER RD. DALLAS, TX 75216OFFICE OF CONSTRUCTION AND FACILITIES

MANAGEMENT DIRECTOR , CENTRAL REGION

06 MAY 2021

BID PACKAGE B

0' 16' 32'8' 64'

NORTH

PLAN

BF

C

D

G

A

H

E

SCALE: 1/8" = 1'-0"F6 MECHANICAL PIPING - FLOOR PLAN - PENTHOUSE AREA F

1 ROUTE LPR FROM STEAM HUMIDIFIERS AND STEAM PRE-HEAT COILS

DOWN THROUGH FLOORSLAB TO LEVEL 2 CEILING. REFER TO LEVEL 2

PIPING PLANS FOR CONTINUATION, AND 83-M-616 FOR LPR RISER

DIAGRAMS.

2 PROVIDE ISOLATION VALVES IN ALL STEAM, CHILLED, AND HOT WATER

BRANCH PIPE AT POINT OF TAKE-OFF FROM MAINS. IF VALVE ACCESS IS

HINDERED BY DUCTWORK/EQUIPMENT, PROVIDE SECOND SET OF

VALVES, LOCATED WHERE PROPER ACCESS CAN BE HAD. TYPICAL FOR

ALL PENTHOUSE BRANCH PIPING.

3 REFER TO WATER COIL PIPING DETAIL C5/83-M-504.

1. REFER TO DRAWING 83-M-001 FOR HVAC PIPING LEGENDS,

ABBREVIATIONS AND GENERAL NOTES.

2. COORDINATE WORK ON THIS SHEET WITH ALL TRADES. WORK SHOWN

ON THIS SHEET IS INTENDED TO PROVIDE THE OVERALL ENGINEERING

DESIGN CONCEPT AND DOES NOT PROVIDE FOR RELOCATIONS,

OFFSETS, ETC., THAT ARE REQUIRED BY THE COORDINATION OF

TRADES. THESE SHALL BE PROVIDED BY THE CONTRACTOR AT NO

ADDITIONAL COST TO THE CONTRACT.

3. ALL MECHANICAL EQUIPMENT REQUIRING ACCESS THAT IS LOCATED

ABOVE GYP. BOARD OR OTHERWISE INACCESSIBLE CEILING SHALL BE

PROVIDED WITH A CEILING ACCESS PANEL SUPPLIED AND INSTALLED BY

THE GENERAL CONTRACTOR. THE MECHANICAL CONTRACTOR SHALL

COORDINATE THE EXACT LOCATION OF THESE ACCESS PANELS WITH

THE GENERAL CONTRACTOR.

4. ISOLATION VALVES SHALL BE PROVIDED IN ALL BRANCH PIPING AND AT

EQUIPMENT CONNECTIONS.

5. INSTALL PIPING TO ALLOW FOR EXPANSION AND CONTRACTION

WITHOUT STRESSING PIPE OR EQUIPMENT CONNECTED.

6. IDENTIFY EACH PIPE WITH LABELING AS REQUIRED BY SPECIFICATIONS.

7. ALL PIPE RUN-OUTS TO INDIVIDUAL VAV TERMINAL UNITS SHALL BE 3/4"

UNLESS NOTED OTHERWISE.

8. ALL VAV TERMINAL UNITS SHALL HAVE TWO-WAY CONTROL VALVES

UNLESS NOTED OTHERWISE.

9. ALL LOW PRESSURE RETURN (LPR) TO BE SLOPED TO 1/8"/LF

10 REFER TO SHEET 83-M-614 FOR THE CHILLED WATER RISER DIAGRAM.

11 REFER TO SHEET 83-M-615 FOR THE HEATING WATER RISER DIAGRAM.

12 REFER TO SHEET 83-M-616 FOR THE STEAM/CONDENSATE RISER

DIAGRAM.

PENTHOUSE

568' - 9"

ROOF LEVEL

588' - 9"

36/72 52ø

83-AHU-04

83-EF-04

14/16

24/40

12/24 1 1/4"

3" HWR

3" HWS 4" CHR

4" CHS

L P

S

MECHANICAL

PENTHOUSE

3A002

PENTHOUSE

568' - 9"

ROOF LEVEL

588' - 9"

83-AHU-04

85/31

36/72

83-EF-04

16/14

123/40

72/36

14/16

/3

3"

4"

1 1/4"

HWR

CHR

83-H-04

1"

L P

S

MECHANICAL

PENTHOUSE

3A002

PENTHOUSE

568' - 9"

ROOF LEVEL

588' - 9"

83-ERU-03

40/86

STEAM PREHEAT

COIL 83-PHC-03,

18/36

36/42

MOTORIZED

ISOLATION

DAMPER

MOTORIZED UNIT

ISOLATION DAMPER

/3

120V MOTORIZED UNIT ISOLATION

DAMPER. COORDINATE INSTALLATION

WITH ELECTRICAL CONTRACTOR, TYP.

MANUAL BYPASS

DAMPER

MANUAL

BYPASS

DAMPER

30/32

36/18

52ø

2"

1 1/4"

3"3"

2"

L P

R

83-AHU-05

32/30

CHS

CHR

3"3"

HWSHWR

24/14

MECHANICAL

PENTHOUSE

3A002

PENTHOUSE

568' - 9"

ROOF LEVEL

588' - 9"

83-ERU-03

/2

44/74

52ø

14/16

16/26

16/14

STEAM PREHEAT COIL

83-PHC-03

18/36

120V MOTORIZED

ISOLATION DAMPER

36/42

/1

83-RF-05

83-RF-04

16/26

18/36

/8

44/74

46/74 BEHIND

18/36 BEHIND

MECHANICAL

PENTHOUSE

3A002

PENTHOUSE

568' - 9"

ROOF LEVEL

588' - 9"

47ø

83-RF-01

36/62

30/60

30/66

83-H-01

83-AHU-01

/2

/6

62/24

2 1/2"

3"

2 1/2"

2 1/2"

3"

4"

4"

C H

S

C H

RH

W

R H

W S

L P

S

1"

L P

R

1 1/4"

62/24

MECHANICAL

PENTHOUSE

3A002

PENTHOUSE

568' - 9"

ROOF LEVEL

588' - 9"

30/60

83-RF-01

66/30

83-AHU-01

24/40

/1

1 1/4"

2 1/2"

4"

4"

2 1/2"

C H

S

C H

R

H W

S H W

R

L P

S

HWRHWS

4" 4"

83-H-01

LPR

MECHANICAL

PENTHOUSE

3A002

D A

A M

P

Drawing Title

Approved Project Director:

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

PSP 309070 Revisions Date

ARCHITECT/ENGINEERS: Office of

Construction and Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

FILE NAME

Project Abbreviation

F

E

D

C

B

A

F

IL

E N

A M

E

FULLY SPRINKLERED

Page Southerland Page, LLP.

1800 Main Street Suite 123

Dallas, TX 75201 pagethink.com

TEL

FAX

ARCHITECTURE / ENGINEERING / INTERIORS / CONSULTING

Austin / Dallas / Denver / Houston / Washington DC /

International Affiliate Offices

214 522 3900

214 522 4380

DWG

W

V A -L

T S C

IF

-D \3

B M

E -S

C I- R -b k in m a n .R

V T

/3

/2

:5 :3

A

M

W:\VA-LTSCIF-D\309070B3ME-SCI-R18-bkinman.RVT

83-M-301

CONSTRUCTION

VA-LTSCI-D

JK

549-820B

KV

MECHANICAL - MECHANICAL ROOM SECTIONS

LONG TERM SPINAL CORD INJURY

VA NORTH TEXAS HEALTH CARE SYSTEM

4500 S. LANCASTER RD. DALLAS, TX 75216OFFICE OF CONSTRUCTION AND FACILITIES

MANAGEMENT DIRECTOR , CENTRAL REGION

06 MAY 2021

BID PACKAGE B

SCALE: 1/4" = 1'-0"F1 83-AHU-04 SECTION 02

SCALE: 1/4" = 1'-0"C1 83-AHU-04 SECTION 01

SCALE: 1/4" = 1'-0"C4 83-ERU-03 SECTION 01

SCALE: 1/4" = 1'-0"F4 83-ERU-03 SECTION 02

SCALE: 1/4" = 1'-0"C7 83-AHU-01 SECTION 01

SCALE: 1/4" = 1'-0"F7 83-AHU-01 SECTION 02

ROOF LEVEL

588' - 9"

20/48

30/66

83-AHU-02

20/48

/6

4"

4" 1 1/2"

2 1/2"2 1/2"

4"

8"

H W

R H W

S

C H

R

L P

S

C H

S

1 1/4"

D83-H-02

MECHANICAL

PENTHOUSE

3A002

PENTHOUSE

568' - 9"

ROOF LEVEL

588' - 9"

108/29

57/32

66/20

85/31

83-AHU-02

/2

83-AHU-02

1 1/2"

4"2 1/2"

4"

8"8"6"6"

1"

H W

S H W

R

C H

S

C H

R

L P

S

H W

R C

H R

L P

S L P

R

D

1 1/4"

MECHANICAL

PENTHOUSE

3A002

PENTHOUSE

568' - 9"

ROOF LEVEL

588' - 9"

83-EF-06

83-ERU-02

MANUAL

BYPASS

DAMPER

MOTORIZED ISOLATION

DAMPER

40/100

/4

3"

MECHANICAL

PENTHOUSE

3A002

PENTHOUSE

568' - 9"

ROOF LEVEL

588' - 9"

83-ERU-02

83-EF-06

42/4824/62

STEAM PREHEAT COIL

83-PHC-02, 1026 LB/HR

@15PSI

SD

/5

24/24

36/60

69/122

/7

69/122

MANUAL BYPASS

DAMPER

MOTORIZED

ISOLATION

DAMPER

MOTORIZED

ISOLATION

DAMPER

MOTORIZED

ISOLATION

DAMPER

S

MANUAL

BYPASS

DAMPER

/8

40/50

HWS

CHS CHR

LPS

HWR

MECHANICAL

PENTHOUSE

3A002

PENTHOUSE

568' - 9"

ROOF LEVEL

588' - 9"

83-AHU-04

83-ERU-03

36/72

83-EF-07

24/14

16/26

83-RF-04

52ø 52ø

12/24

/2

/3

16/26

24/40

83-RF-05

14/24 14/24

12/2420/2012/24

STEAM PREHEAT COIL

83-PHC-03

83-AHU-05

83-ARU-01

36/42

/3

1 1/4"

3"

4"

3" 1 1/4"

1"

2"1"

2"

2"

1 1/4" 3"

3"

1"

3/4"

C H

S

C H

R

L P

S

HWR

L P

R

CHS CHS

C H

R

C H

S

H W

SH

W

R

CHR

L P

SC

H

R

C H

S

MANUAL BYPASS DAMPER

MECHANICAL

PENTHOUSE

3A002

D A

A M

P

Drawing Title

Approved Project Director:

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

PSP 309070 Revisions Date

ARCHITECT/ENGINEERS: Office of

Construction and Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

FILE NAME

Project Abbreviation

F

E

D

C

B

A

F

IL

E N

A M

E

FULLY SPRINKLERED

Page Southerland Page, LLP.

1800 Main Street Suite 123

Dallas, TX 75201 pagethink.com

TEL

FAX

ARCHITECTURE / ENGINEERING / INTERIORS / CONSULTING

Austin / Dallas / Denver / Houston / Washington DC /

International Affiliate Offices

214 522 3900

214 522 4380

DWG

W

V A -L

T S C

IF

-D \3

B M

E -S

C I- R -b k in m a n .R

V T

/3

/2

:5 :3

A

M

W:\VA-LTSCIF-D\309070B3ME-SCI-R18-bkinman.RVT

83-M-302

CONSTRUCTION

VA-LTSCI-D

JK

549-820B

KV

MECHANICAL - MECHANICAL ROOM SECTIONS

LONG TERM SPINAL CORD INJURY

VA NORTH TEXAS HEALTH CARE SYSTEM

4500 S. LANCASTER RD. DALLAS, TX 75216OFFICE OF CONSTRUCTION AND FACILITIES

MANAGEMENT DIRECTOR , CENTRAL REGION

06 MAY 2021

BID PACKAGE B

SCALE: 1/4" = 1'-0"F1 83-AHU-02 SECTION 02

SCALE: 1/4" = 1'-0"C1 83-AHU-02 SECTION 01

SCALE: 1/4" = 1'-0"C6 83-ERU-02 SECTION 02

SCALE: 1/4" = 1'-0"C3 83-ERU-02 SECTION 01

SCALE: 1/4" = 1'-0"F3 83-AHU-05 SECTION 01

ROOF LEVEL

588' - 9"

83-AHU-03

36/62

/6

42ø 30/62

36/62

83-H-03

/1

1 1/4"

L P

S

1"

D

MECHANICAL

PENTHOUSE

3A002

PENTHOUSE

568' - 9"

ROOF LEVEL

588' - 9"

83-AHU-03

/2

/3

66/32

83-H-03

36/6262/36

4"

6" 8"

4"

1 1/4"

L P

S

CHR CHS

LPS

CHR

CHR

HWR

CHR

CHS

HWR

MECHANICAL

PENTHOUSE

3A002

PENTHOUSE

568' - 9"

ROOF LEVEL

588' - 9"

83-ERU-01

36/54

36/60

32/66

69/122

/6

SD 32/66

MOTORIZED UNIT

ISOLATION DAMPER

120V MOTORIZED UNIT

ISOLATION DAMPER

120V MOTORIZED UNIT

ISOLATION DAMPER

L P

R

BLANK-OFF UNUSED

PORTION OF LOUVER

120V MOTORIZED

OUTSIDE AIR DAMPER

MECHANICAL

PENTHOUSE

3A002

PENTHOUSE

568' - 9"

ROOF LEVEL

588' - 9"

36/54

83-ERU-01

83-EF-05

66/32

MANUAL VOLUME

DAMPER32/66

60/36

60/36

3/4"

CHS

83-FCU-25

MECHANICAL

PENTHOUSE

3A002

LEVEL 01

535' - 3"

LEVEL B1

519' - 3"

GENERATOR MUFFLER

14ø

REFER TO SPECIFICATION

SECTION 26 32 13.

NORMAL

POWER

SWITCHGEAR

B1B012

D A

A M

P

Drawing Title

Approved Project Director:

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

PSP 309070 Revisions Date

ARCHITECT/ENGINEERS: Office of

Construction and Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

FILE NAME

Project Abbreviation

F

E

D

C

B

A

F

IL

E N

A M

E

FULLY SPRINKLERED

Page Southerland Page, LLP.

1800 Main Street Suite 123

Dallas, TX 75201 pagethink.com

TEL

FAX

ARCHITECTURE / ENGINEERING / INTERIORS / CONSULTING

Austin / Dallas / Denver / Houston / Washington DC /

International Affiliate Offices

214 522 3900

214 522 4380

DWG

W

V A -L

T S C

IF

-D \3

B M

E -S

C I- R -b k in m a n .R

V T

/3

/2

:5 :4

A

M

W:\VA-LTSCIF-D\309070B3ME-SCI-R18-bkinman.RVT

83-M-303

CONSTRUCTION

VA-LTSCI-D

FG

549-820B

KV

MECHANICAL - MECHANICAL ROOM SECTIONS

LONG TERM SPINAL CORD INJURY

VA NORTH TEXAS HEALTH CARE SYSTEM

4500 S. LANCASTER RD. DALLAS, TX 75216OFFICE OF CONSTRUCTION AND FACILITIES

MANAGEMENT DIRECTOR , CENTRAL REGION

06 MAY 2021

BID PACKAGE B

SCALE: 1/4" = 1'-0"C3 83-AHU-03 SECTION 01

SCALE: 1/4" = 1'-0"F3 83-AHU-03 SECTION 02

SCALE: 1/4" = 1'-0"C6 83-ERU-01 SECTION 01

SCALE: 1/4" = 1'-0"F7 83-ERU-01 SECTION 02

SCALE: 1/4" = 1'-0"F1 GENERATOR SECTION

LEVEL 02

552' - 9"

16/24

83-CRC-06

NURSE

ADMINISTRATOR

2A010

16/30

6"ø S-1

120 CFM

6"ø S-1

120 CFM

6"ø S-1

120 CFM

6ø

16/28

6ø

CHR

LPR

1 1/2"

1"

L P

R

NURSE

ADMINISTRATOR

2A011

CORRIDOR

2B023

NURSE

ADMINISTRATOR

2A008

LEVEL 02

552' - 9"

34/18

1 1/2"

8"ø E-1

185 CFM

14ø

12ø

12ø

LPR

PUBLIC

LOBBY

2A002

STORAGE SCI

HOME CARE

2F005

OFFICE

CORRIDOR

2F197

LEVEL 01

535' - 3"

LEVEL 02

552' - 9"

32/14

36/18

24/16

83-TU-1-18

8"ø E-3 190 CFM6"ø S-3

65 CFM

10"ø R-1

265 CFM

HWRHWS

10ø

PATIENT

BATHROOM

1D004

RESIDENT

CORRIDOR

1D001

LEVEL 01

535' - 3"

16/24

14/32 12/26

6"ø S-3 65 CFM 10"ø R-1

245 CFM

10"ø R-1

245 CFM

8"ø S-4

185 CFM

8"ø S-4

185 CFM

8"ø S-4

185 CFM

8"ø S-4

185 CFM

PATIENT

BATHROOM

1D004

ONE-BED

PATIENT

ROOM

1D003

ONE-BED

PATIENT

ROOM

1D005

RESIDENT

CORRIDOR

1D001

LEVEL B1

519' - 3"

LEVEL B2

501' - 3"

/1

83-CHP-02

83-FCU-28

42x18 E-2

1600 CFM

8"

6" 8"

10" HWS

H W

R

H W

S

H W

R

CHR

1"

8"

4" 4"

1"

2" 2"

10" 10" C

H S

C H

R

D

1 1/4"1 1/4"

EXIT STAIR

(7)

B2B001

EQUIPMENT

ROOM

B2B005

MECHANICAL

PUMP ROOM

B2B002

FUTURE

EXPANSION

B1B009

LEVEL B1

519' - 3"

LEVEL B2

501' - 3"

83-FCU-28

/2

14/14

83-CP-01

8"

10/12

14/14

12x10ø S-2

340 CFM

12x10ø S-2

330 CFM

12x10ø S-2

330 CFM

12x10ø S-2

340 CFM

24/16

LPR

PCR

L P

R

P C

R

LPS

V

MPS

H

W R

M P

S

8"

3" 2"

2"

6"8"

1 1/4"

CHR

H W

S

H W

R

V

V

C H

S

C H

S

L P

S

8" 6"

10"

6"10"4"8"

4" 8"

CHILLER ROOM EXHAUST

INTAKE GRILLE

83-HX-01

EQUIPMENT

ROOM

B2B005

EXIT STAIR

(7)

VESTIBULE

B2B003

EQUIPMENT

ROOM

B2B006

MECHANICAL

PUMP ROOM

B2B002

D A

A M

P

Drawing Title

Approved Project Director:

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

PSP 309070 Revisions Date

ARCHITECT/ENGINEERS: Office of

Construction and Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

FILE NAME

Project Abbreviation

F

E

D

C

B

A

F

IL

E N

A M

E

FULLY SPRINKLERED

Page Southerland Page, LLP.

1800 Main Street Suite 123

Dallas, TX 75201 pagethink.com

TEL

FAX

ARCHITECTURE / ENGINEERING / INTERIORS / CONSULTING

Austin / Dallas / Denver / Houston / Washington DC /

International Affiliate Offices

214 522 3900

214 522 4380

DWG

W

V A -L

T S C

IF

-D \3

B M

E -S

C I- R -b k in m a n .R

V T

/3

/2

:5 :5

A

M

W:\VA-LTSCIF-D\309070B3ME-SCI-R18-bkinman.RVT

83-M-304

CONSTRUCTION

VA-LTSCI-D

JK

549-820B

KV

MECHANICAL - MECHANICAL DUCT SECTIONS

LONG TERM SPINAL CORD INJURY

VA NORTH TEXAS HEALTH CARE SYSTEM

4500 S. LANCASTER RD. DALLAS, TX 75216OFFICE OF CONSTRUCTION AND FACILITIES

MANAGEMENT DIRECTOR , CENTRAL REGION

06 MAY 2021

BID PACKAGE B

SCALE: 1/4" = 1'-0"F1 DUCT SECTION 05

SCALE: 1/4" = 1'-0"B5 DUCT SECTION 02

SCALE: 1/4" = 1'-0"F7 DUCT SECTION 07

SCALE: 1/4" = 1'-0"F3 DUCT SECTION 06

SCALE: 1/4" = 1'-0"D1 DUCT SECTION 04

SCALE: 1/4" = 1'-0"B1 DUCT SECTION 01

LEVEL 02

552' - 9"

PENTHOUSE

568' - 9"

16/12 18/3618/34 18/36

16/12

16/18

12"ø R-1

330 CFM

8"ø S-1 175 CFM8"ø S-1

175 CFM

12ø

8ø

OFFICE

CORRIDOR

2A030

LEVEL 01

535' - 3"

LEVEL 02

552' - 9"

16/40 18/56

18/40

10ø

24/22

18/32

10ø

2 1/2"

3/4"

10"ø R-1

275 CFM

8"ø S-1

160 CFM

HWR

HWR

3"

RESIDENT

CORRIDOR

1A041

LEVEL 01

535' - 3"

LEVEL 02

552' - 9"

/5

32/32

46/20 F

6"ø S-1

90 CFM

8"ø E-1

225 CFM

MECH CHASE

N|A

CLEAN

UTILITY

ROOM

1A011

RESIDENT

CORRIDOR

1A041

STORAGE

PATIENT

1A030

LEVEL 01

535' - 3"

LEVEL 02

552' - 9"

18/52

70/18

18/36

12ø

52/18

24/28

6"ø R-1 80 CFM6"ø S-1

80 CFM

8"ø R-1

215 CFM

2"

3/4"

HWRHWR

HWS

MEDICATION

ROOM

1B032

RESIDENT

CORRIDOR

1B009

STORAGE

LITTER

1B027

SUPPLY

CLOSET

1B029

LEVEL B1

519' - 3"

LEVEL B2

501' - 3"

83-CHP-02

10"

10" 10"

10" 8"

8"

6"

2"

CHR

C H

S

HWS

H W

R

V

LEVEL B1

519' - 3"

LEVEL B2

501' - 3"

83-FCU-01

83-CHP-02

83-CHP-01

12x10 S-2

500 CFM

12x10 S-2

500 CFM

12x10 S-2

500 CFM

14/1416/20

8" 6" 6"

4"

P C

R

HWS

HPS

CHS

H P

S

10"10"

10"

2"

1"

D

V

1"

PCR 1" DBEHIND

2"D

EQUIPMENT

ROOM

B2B006

LEVEL B1

519' - 3"

E.3

FIRE RATED

PARTITION.

EXIT STAIR

(1)

B1A007

D A

A M

P

Drawing Title

Approved Project Director:

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

PSP 309070 Revisions Date

ARCHITECT/ENGINEERS: Office of

Construction and Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

FILE NAME

Project Abbreviation

F

E

D

C

B

A

F

IL

E N

A M

E

FULLY SPRINKLERED

Page Southerland Page, LLP.

1800 Main Street Suite 123

Dallas, TX 75201 pagethink.com

TEL

FAX

ARCHITECTURE / ENGINEERING / INTERIORS / CONSULTING

Austin / Dallas / Denver / Houston / Washington DC /

International Affiliate Offices

214 522 3900

214 522 4380

DWG

W

V A -L

T S C

IF

-D \3

B M

E -S

C I- R -b k in m a n .R

V T

/3

/2

:4

:2

A

M

W:\VA-LTSCIF-D\309070B3ME-SCI-R18-bkinman.RVT

83-M-305

CONSTRUCTION

VA-LTSCI-D

RH

549-820B

KV

MECHANICAL - MECHANICAL DUCT SECTIONS

LONG TERM SPINAL CORD INJURY

VA NORTH TEXAS HEALTH CARE SYSTEM

4500 S. LANCASTER RD. DALLAS, TX 75216OFFICE OF CONSTRUCTION AND FACILITIES

MANAGEMENT DIRECTOR , CENTRAL REGION

06 MAY 2021

BID PACKAGE B

SCALE: 1/4" = 1'-0"B4 DUCT SECTION 10

SCALE: 1/4" = 1'-0"B7 DUCT SECTION 11

SCALE: 1/4" = 1'-0"B1 DUCT SECTION 09

SCALE: 1/4" = 1'-0"D1 DUCT SECTION 12

SCALE: 1/4" = 1'-0"F5 MECHANICAL ROOM SECTION 02

SCALE: 1/4" = 1'-0"F1 MECHANICAL ROOM SECTION 01

1" D

SCALE: 1/8" = 1'-0"D7 DUCT SECTION 13

bkinman Snapshot bkinman Snapshot

83-ERU-01

66/32

60/36

30/1430/14

78/4566/32

/6

66/32

66/32

83-EF-06

83-ERU-02

/4

36/40

24/14

60/36

122/69

60/36

50/40

26/14

83-ERU-02

83-ERU-03

32/30

32/30

/3

74/44

36/18

3"

3" 6"

6"

2"

/1

52ø

D A

A

M P

Drawing Title

Approved Project Director:

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

PSP 309070 Revisions Date

ARCHITECT/ENGINEERS: Office of

Construction and Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

FILE NAME

Project Abbreviation

F

E

D

C

B

A

F

IL

E N

A M

E

FULLY SPRINKLERED

Page Southerland Page, LLP.

1800 Main Street Suite 123

Dallas, TX 75201 pagethink.com

TEL

FAX

ARCHITECTURE / ENGINEERING / INTERIORS / CONSULTING

Austin / Dallas / Denver / Houston / Washington DC /

International Affiliate Offices

214 522 3900

214 522 4380

DWG

C

U se rs \b k in m a n \D o c u m e n ts

\3 b M

E -S

C I- R -C

E N

T R A L b k in m a n R K W

J .r v t

/3

/2

:3

:2

P

M

C:\Users\bkinman\Documents\309070b3ME-SCI-R18-CENTRAL_bkinmanR4KWJ.rvt

83-M-306

CONSTRUCTION

VA-LTSCI-D

JK

549-820B

KV

MECHANICAL - MECHANICAL ROOM - 3D VIEWS

LONG TERM SPINAL CORD INJURY

VA NORTH TEXAS HEALTH CARE SYSTEM

4500 S. LANCASTER RD. DALLAS, TX 75216OFFICE OF CONSTRUCTION AND FACILITIES

MANAGEMENT DIRECTOR , CENTRAL REGION

06 MAY 2021

BID PACKAGE B

SCALE:C7 83-ERU-01 - 3D VIEW

SCALE:F3 83-ERU-02 - 3D VIEW

SCALE:F7 83-ERU-03 - 3D VIEW

83-MP-101G
83-MP-102
83-MP-102A
83-MP-102B
83-MP-102F
83-MP-103
83-MP-103A
83-MP-103B
83-MP-103F
83-M-301
83-M-302
83-M-303
83-M-304
83-M-305
83-M-306

File details come from the government source that posted it. Updated .