36C10F19R0003-024.pdf
PDF 1 MB Posted
- Solicitation number
- 36C10F19R0003
About this file
36C10F19R0003 COMBINED ELECTRICAL _ TELECOM.pdf
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DNUP
DN
F B
F B
F B
F B
C R
C R
DC
F
4 5 6
EXISTING BUILDING 1
2ND FLOOR
AREA W
EXISTING BUILDING 30
2ND FLOOR
NE
F
B
S
D
E
E.6
E.7 F
3.4
6.5
6.1
12.8 x.8x.7x.6x.5x.4 x.19 x.18 x.17 x.16 x.14 x.2 x.C
EA
x.J x.L x.N x.P x.3
J 11
D
D
F B
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of
Facilities
Management o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t 4 o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
BIDDING DOCUMENTS - FEBRUARY 22, 2019
VA CARES CONSOLIDATION
VAMC, PITTSBURGH, PA
CONNECTING BRIDGE
ESD-801
646CA2500.23
AuthorChecker
ELECTRICAL DEMOLITION
PLAN
VAPHS UNIVERSITY DRIVE
1 & 30
1/8" = 1'-0"
ELECTRICAL DEMOLITION PLAN
Key Notes
EXISTING RECESSED LIGHTING, EXIT SIGNS, DUPLEX RECEPTACLES AND
FIRE ALARM DEVICES SHOWN HERE SHALL BE DE-ENERGIZED,
DISCONNECTED AND REMOVED BACK TO SOURCE, UNLESS NOTED
OTHERWISE. TYPICAL.
DISCONNECT AND REMOVE EXISTING CARD READERS. REWORK
EXISTING EQUIPMENT, WIRING, CIRCUITS, ETC. TO ACCOMMODATE NEW
CARD READER NEAR THIS LOCATION. SEE ET1-101 FOR NEW WORK.
EXISTING SURFACE MOUNTED FLUORESCENT FIXTURES MOUNTED UNDER
PASSAGE CORRIDOR IN SECOND FLOOR MECHANICAL ROOM SHALL BE
DE-ENERGIZED, DISCONNECTED AND REMOVED TO SOURCE. TYPICAL.
EXISTING PANELBOARD W2D2 SHALL BE DE-ENERGIZED, DISCONNECTED
AND REMOVED. SEE RISER DIAGRAM ON SHEET EP5-101 FOR ADDITIONAL
INFORMATION.
EXISTING PANELBOARD W2D1 SHALL BE DE-ENERGIZED, DISCONNECTED
AND REMOVED. SEE RISER DIAGRAM ON SHEET EP5-101 FOR ADDITIONAL
INFORMATION.
EXISTING PANELBOARD W2E SHALL BE DE-ENERGIZED, DISCONNECTED
AND REMOVED. SEE RISER DIAGRAM ON SHEET EP5-101 FOR ADDITIONAL
INFORMATION.
EXISTING DATA CABLES SERVING EXISTING LAB ARE TO BE DE-
ENERGIZED, DISCONNECTED AND REMOVED BACK TO EXISTING IT
CLOSET.
EXISTING 3/4" EMT CONDUIT WITH 6 #12 AWG CONDUCTOR SHALL BE
RELOCATED TO NEW CHASE. SEE DRAWING EP1-101 FOR ADDITIONAL
INFORMATION.
EXISTING STAIRWELL PAGING SPEAKER TO BE RELOCATED. SEE ET1-101
FOR NEW WIRING SCHEME.
EXISTING CABINET HEATER TO BE DE-ENERGIZED AND DISCONNECTED.
MAINTAIN EXISITNG 120 VOLT 20 AMP CIRCUIT FOR EXTENSION TO NEW
HEATER.
EXISTING STAIRWELL LIGHT FIXTURE TO BE RELOCATED. SEE EL1-101
FOR NEW LOCATION AND WIRING.
MAINTAIN EXISTING NORMAL/EMERGENCY CIRCUIT FOR EXTENSION TO
NEW PA AMPLIFIER IN NEW ELECTRICAL ROOM. SEE EP1-101 FOR NEW
LOCATION.
EXISTING SECURITY TRAC DURESS CEILING SENSOR TO REMAIN AND BE
REINSTALLED IN NEW CEILING. PROTECT FROM PHYSICAL DAMAGE AND
DUST DURING CONSTRUCTION. MAINTAIN EXISTING WIRING.
GENERAL DEMOLITION NOTES:
A. REMOVE ALL ELECTRICAL EQUIPMENT ON OR IN EXISTING WALLS,
CEILINGS AND PARTITIONS WHICH ARE TO BE DEMOLISHED. REMOVE
ALL EXPOSED PORTIONS OF BRANCH CIRCUIT AND CONTROL VOLTAGE
WIRING AND CONDUITS.
B. WHERE EXISTING WALLS ARE TO REMAIN, REMOVE ALL EXPOSED
RACEWAYS, SURFACE AND RECESSED OUTLET BOXES, ETC. WHICH
ARE NOT TO BE REUSED. WHERE NEW CONDUITS AND OUTLETS ARE
TO BE ADDED TO EXISTING WALLS IN FINISHED ROOMS, THEY SHALL
BE CONCEALED BY CUTTING AND PATCHING THE WALLS.
C. UTILIZE EXISTING OUTLET BOXES AND RACEWAY SYSTEMS WHEREVER
PRACTICAL IN RENOVATION AREAS. WHERE SUCH EXISTING OUTLET
BOXES ARE USED, INSTALL NEW WIRING DEVICES, COVERPLATES, AND
WIRING. SPECIAL COVERPLATES MAY BE REQUIRED TO SUIT
CONDITIONS.
D. REARRANGE EXISTING CONDUITS AND WIRING TO ACCOMMODATE NEW
CIRCUIT ARRANGEMENTS INDICATED AND TO MAINTAIN CONTINUITY OF
EXISTING CIRCUITS FEEDING DEVICES THAT ARE TO REMAIN.
E. BE RESPONSIBLE TO REMOVE AND REINSTALL EXISTING ELECTRICAL
EQUIPMENT TO ACCOMMODATE THE WORK OF OR DISTURBED BY ALL
TRADES.
F. STOCKPILE REMOVED LUMINAIRES, POWER AND COMMUNICATION
DEVICES ON JOB SITE FOR REUSE UNTIL TIME OR PROJECT
CLOSEOUT, THEN REMOVE THOSE FROM SITE THAT THE OWNER DOES
NOT WISH TO SALVAGE.
G. EXISTING DEVICE LOCATIONS WERE INDENTIFIED AS COMPLETELY AS
POSSIBLE BY A SITE SURVEY AND BY RECORD DOCUMENTS AS
AVAILABLE. BE RESPONSIBLE FOR PROPER DEMOLITION AND REWORK
OF DEVICES NOT SHOWN ON DRAWINGS TO CONFORM WITH INTENT OF
DOCUMENTS.
H. MAINTAIN CONTINUOUS SERVICE TO ALL LIGHTING, POWER, AND
SIGNALING/ALARM CIRCUITS THAT ARE OUTSIDE OF THE RENOVATION
AREA BUT MAY BE AFFECTED BY THE WORK. CLOSELY COORDINATE
REQUIRED OUTAGES WITH THE VA AND SCHEDULE WORK TO MINIMIZE
DISRUPTION OF SERVICES.
1 AMENDMENT 3 01-31-17
RECESSED/SURFACE/PENDANT
MOUNTED LINEAR FIXTURE
Lighting Symbols
RECESSED/SURFACE
MOUNTED ROUND DOWNLIGHT
WALL/SURFACE MOUNTED FIXTURE
WALL MOUNTED EXIT SIGN - SINGLE
OR DOUBLE FACE AND CHEVRONS AS
SHOWN ON FLOOR PLANS
CEILING MOUNTED EXIT SIGN - SINGLE OR
DOUBLE FACE AND CHEVRONS AS
SHOWN ON FLOOR PLANS
F11
INDICATES
LUMINAIRE TYPE (F11)
INDICATES
CIRCUIT NUMBER(2) -
PANEL INDICATED AT
HOME RUN
LUMINAIRE
SYMBOL
1.
2. THE LIGHTING SYSTEM WIRING SHALL BE SIZED IN
ORDER TO LIMIT THE VOLTAGE DROP TO 3% FROM THE
LAST FIXTURE IN ANY CIRCUIT TO THE PANELBOARD.
3. ALL LIGHTING FIXTURE FINISHES SHALL BE COORDINATED
WITH ARCHITECT PRIOR TO INSTALLATION.
4. LIGHTING SHALL BE MOUNTED UTILIZING METHODS OF
ATTACHMENT IN ACCORDANCE WITH NEC, LATEST
APPLICABLE ARTICLE AND UL REQUIREMENTS.
CONTRACTOR IS RESPONSIBLE TO COORDINATE FIXTURE
INSTALLATION HARDWARE WITH CEILING TYPE.
6.
7.
8.
9.
10.
General Notes
THE ELECTRICAL POWER DISTRIBUTION SYSTEM
WILL PROVIDE A VOLTAGE DROP NOT TO EXCEED
5% BETWEEN THE TRANSFORMER SECONDARY AND
THE EQUIPMENT TO BE SERVED.
ALL EMPTY CONDUITS (ELECTRICAL, TELEPHONE,
DATA, TV, ETC.) SHALL HAVE A CONDUIT MEASURING
TAPE INSTALLED WITHIN THEM. THE TAPE SHALL BE
SUITABLE FOR USE AS A PULLING LINE. TAPE SHALL
BE RATED 130 LB. TENSILE STRENGTH (GREENLEE 435
OR EQUAL) SIZES 2 INCHES OR LARGER SHALL BE
SUPPLEMENTED WITH 200 LB. NYLON LINE, TIED AT
BOTH ENDS TO TAPE.
ALL PULL LINES SHALL BE IDENTIFIED LISTING ORIGIN,
INTERMEDIATE PULL POINTS AND TERMINATION,
SPECIFIC LOCATIONS OF ORIGIN, INTERMEDIATE PULL
POINTS AND TERMINATION. SPECIFIC LOCATIONS OF
ORIGIN, INTERMEDIATE PULL POINTS AND
TERMINATION SHALL BE INDICATED.
WHERE CONDUIT, CABLES, DUCTWORK, OR PIPING
PASSES THROUGH FIRE RATED FLOORS OR WALLS,
THE SLEEVES SHALL BE COMPLETELY SEALED WITH A
FIRESTOP MATERIAL THAT IS UL LISTED, AND
ACCEPTED BY THE BUILDING DEPARTMENT AND FIRE
DEPARTMENT AS BEING SUITABLE FOR THIS SERVICE
SUCH AS DOW CORNING CORP., SILICONE
ELASTOMER, DOW CORNING 3-6548 SILICONE TRV
FOAM, OR APPROVED EQUAL. THIS MATERIAL SHALL
BE INSTALLED IN ACCORDANCE WITH THE
REQUIREMENTS OF THE MANUFACTURER TO MAINTAIN
THE FIRE RATING OF THE PENETRATED WALL OR
FLOOR.
ELECTRICAL DRAWINGS ARE DIAGRAMMATIC ONLY.
REFER TO ARCHITECTURAL DRAWINGS FOR EXACT
LOCATIONS OF DEVICES AND LIGHTING FIXTURE
LOCATIONS.
ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE
LATEST EDITION OF THE NATIONAL ELECTRICAL CODE
(NFPA 70) AND LOCAL APPLICABLE CODES.
PROVIDE PROPER ACCESS PANELS AS REQUIRED IN
WALLS AND GWB CEILINGS FOR ANY EQUIPMENT,
DEVICES, SWITCHES, CONTRACTORS, PULL AND
JUNCTION BOXES ETC. REQUIRING PANELS TO BE
PROVIDED BY TRADE CONTRACTOR FOR INSTALLATION
G.C.
Electrical Symbols
DUPLEX RECEPTACLE
QUAD RECEPTACLE
WEATHER-PROOF GROUND
FAULT ISOLATED DUPLEX
RECEPTACLE
GROUND FAULT ISOLATED DUPLEX RECEPTACLE
DUPLEX RECEPTACLE MOUNTED 6" ABOVE COUNTER
DUPLEX RECEPTACLE MOUNTED 48" AFF
WP/GFI
GFI
+48
SPECIAL RECEPTACLE NEMA TYPE AS SHOWN
MOTOR CONNECTION - THREE PHASE
MOTOR CONNECTION - SINGLE PHASE
BRANCH CIRCUIT -
(2)#12 AWG AND #12AWG G. IN 3/4" C. (EMT) U.N.O.
A-1 HOMERUN TO PANEL BOARD
BRANCH CIRCUIT NUMBER
PANEL DESIGNATION
GROUNDING ROD
PANELBOARD/RELAY LIGHTING CONTROL PANEL
INDICATES:
PANEL (B1)-
CIRCUIT NUMBER (3)B1-3
DEVICE SYMBOL
Electrical Abbreviations
Mounting Heights Schedule
6'-8" AFF (BOTTOM OF DEVICE) OR 6"
BELOW FINISHED CEILING, (TOP OF
DEVICE) WHICH EVER IS LOWER
REFERENCE LUMINAIRE
SCHEDULE FOR MOUNTING
REQUIREMENTS
6'-6"
6'-0"
5'-0"
3'-10"
(CENTER OF DEVICE)
3'-6'
(TOP OF DEVICES)
2'-0"
1'-6"
FIRE ALARM HORNS /
STROBES
PENDANT MOUNTED
LUMINARIES
TOP OF PANELBOARDS,
CABINETS
TOP OF DISCONNECT
SWITCHES, STARTERS,
AND CONTACTORS
LIGHTS SWITCHES, FIRE ALARM
PULL STATIONS, MANUAL
MOTOR STARTERS, FIREMAN'S
TELEPHONES, NURSE CALL
PULL CHORD, PUSH BUTTON,
DUTY STATIONS AND PANIC
BUTTONS
WALL MOUNTED
HANDICAPPED
TELEPHONE OUTLETS
ELECTRICAL
RECEPTACLES IN
MECHANICAL /
ELECTRICAL ROOMS &
ELEVATOR MACHINE
ROOMS
ELECTRICAL RECEPTACLES
(U.N.O.) COMMUNICATIONS /
DATA OUTLETS (U.N.O.)
0'-0" FINISHED
FLOOR
NOTE;
1. CTR - MOUNTED 6" ABOVE COUNTER OR BACKSPLASH.
12. THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL
LOCATIONS OF ELECTRICAL DEVICES PRIOR TO
INSTALLATION. THE ELECTRICAL CONTRACTOR IS
RESPONSIBLE FOR ALL MEANS AND METHODS OF
INSTALLATION OF THE FOLLOWING ELECTRICAL
DEVICES BUT IS NOT LIMITED TO ALL POKE
THROUGH'S, RECEPTACLES, COMMUNICATION ROUGH-
INS, JUNCTION BOXES, ETC. ALL ROUTING AND
INSTALLATION OF RACEWAY FEEDING ELECTRICAL
DEVICES SHALL BE INSTALLED NEAT AND FLUSH TO
SURFACE (WHERE NOT IN DRYWALL) AND SHALL BE
CONCEALED FROM VIEW IN DRYWALL WHERE APPLIED.
PULL BOXPB
JUNCTION BOXJ
DUPLEX RECEPTACLE ON NORMAL / EMERGENCY CIRCUIT
QUAD RECEPTACLE ON NORMAL / EMERGENCY CIRCUIT
SINGLE RECEPTACLE
NORMAL EMERGENCY
SITE LIGHTING BOLLARD
LUMINAIRE TYPES
Electrical Abbreviations
PRI PRIMARY
PRN PRESENT LIGHTING FIXTURE,
SWITCH, DEVICE, ETC., TO BE
REMOVED AND REPLACED WITH
NEW
PRR PRESENT LIGHTING FIXTURE,
SWITCH, DEVICE,, ETC., SHOWN AT
NEW LOCATION
PRX PRESENT LIGHTING FIXTURE,
SWITCH, DEVICE, ETC., TO BE
REMOVED AND OUTLET BOX
EXTENSION INSTALLED FOR
SURFACE CONDUIT OR SMR AND
WIRE EXTENSION TO NEW OUTLET
SHOWN. REINSTALL PRESENT
LIGHTING FIXTURE, SWITCH,
DEVICE, ETC.
PWR POWER
REC/RECPT RECEPTACLE
REQ'D REQUIRED
RGS RIGID GALVANIZED STEEL
RMC RIGID GALVANIZED METAL
CONDUIT
RPC REMOVE PRESENT FIXTURE,
SWITCH, DEVICE, ETC., AND CAP
OUTLET
RPP REMOVE PRESENT FIXTURE,
SWITCH, DEVICE, ETC., PATCH THE
PLASTER IF IN PLASTER: CAP IF IN
METAL OR WOOD
RPX REMOVED PRESENT FIXTURE,
WITCH, DEVICE, ETC., WIRE AND
ALL RELATED EXPOSED RACEWAY
INSOFAR AS IS POSSIBLE. ALL
DAMAGED SURFACES TO BE
REPAIRED
SEC SECONDARY
SM SURFACE MOUNTED
SW SWITCH
SWBD SWITCHBOARD
TEL / TELE TELEPHONE
TL TWIST LOCK
TP TAMPER PROOF
TV TELEVISION
TYP TYPICAL
UC UNDER COUNTER
UCR UNDER COUNTER REFRIGERATOR
RECEPTACLE
UH UNIT HEATER
UL UNDERWRITERS' LABORATORIES,
INC.
UNO UNLESS NOTED OTHERWISE
V VOLTAGE
VT VAPOR TIGHT
W WATT OR WIRE
W/ WITH
W/GRD WITH GROUND WIRE
W/O WITHOUT
WP WEATHER PROOF ENCLOSURE
WT WATER TIGHT
XA EXISTING TO BE REMOVED
COMPLETELY
XR EXISTING TO BE REMOVED AND
RELOCATED
XRN EXISTING TO BE REMOVED AND
REPLACED WITH NEW DEVICE
XRR RELOCATED EXISTING EQUIPMENT
Y STAR OR WYE DISTRIBUTION
SYSTEM
NE NORMAL / EMERGENCY POWER
5.
A/AMP AMPERE
AFCI ARC FAULT INTERRUPTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AL ALUMINUM
AWG AMERICAN WIRE GAUGE
BKR BREAKER
C CONDUIT
CB CIRCUIT BREAKER
CC COMMUNICATION / NETWORK
CONTRACTOR
CCT/CKT CIRCUIT
CLG CEILING
CO CONVENIENCE OUTLET
CONN CONNECTION
CTR COUNTER
CU COPPER
DISC DISCONNECT
DN DOWN
DS DISCONNECT SWITCH
DWG DRAWING
E/EM EMERGENCY OR EMERGENCY
SYSTEM
EA EACH
EC ELECTRICAL CONTRACTOR
EF EXHAUST FAN
EH ELECTRIC HEAT
ELEC ELECTRICAL
EMT ELECTRIC METALLIC TUBING
EQ/EQUIP EQUIPMENT
EUH ELECTRIC UNIT HEATER
EWC ELECTRIC WATER COOLER
EX EXISTING
F FIXTURE
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FBO FURNISHED BY OTHERS WITH ALL
RELATED ELECTRICAL WORK BY
ELECTRICAL CONTRACTOR
FC FOOTCANDLES
FDR FEEDER
FH FUME HOOD
FL FLOOR
FLA FULL LOAD AMPERE
FLUOR FLUORESCENT
GRN/GND GROUND
GC GENERAL CONTRACTOR
GFI GROUND FAULT INTERRUPTER
HC HEATING, VENTILATION, AIR
CONDITIONING CONTRACTOR
HID HIGH INTENSITY DISCHARGE
HP HORSEPOWER
HPF HIGH POWER FACTOR
HTR HEATER
HVAC HEATING, VENTILATION, AIR
CONDITIONING
HZ HERTZ
IN INCH
JB/JBOX JUNCTION BOX
K THOUSAND
KVA KILO-VOLT AMPERES
KW KILOWATT
LED LIGHT EMITTING DIODE
LCP LIGHTING CONTROL PANEL
LTG LIGHTING
LRP LIGHTING REPLAY PANEL
LV LOW VOLTAGE
MC MECHANICAL CONTRACTOR
MCB MAIN CIRCUIT BREAKER
MDP MAIN DISTRIBUTION PANEL
MFR MANUFACTURER
MH MANHOLE
MLO MAIN LUGS ONLY
MSW MAIN SWITCH AND FUSE
MTD MOUNTED
MTG MOUNTING
MTG HT MOUNTING HEIGHT
N/A NON APPLICABLE
NEC NATIONAL ELECTRIC CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURERS ASSOCIATION
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN THIS CONTRACT
NL NIGHT LIGHT
NO / # NUMBER
NTS NOT TO SCALE
OC ON CENTER
OEM ORIGINAL EQUIPMENT
MANUFACTURER
OSHA OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION
P POLE
PB PUSH BUTTON
PBOX PULL BOX
PC PLUMBING CONTRACTOR
PH / Ø PHASE
PNL PANELBOARD
POS POSITION
PR PRESENT LIGHTING FIXTURE, SWITCH,
DEVICE, ETC., TO REMAIN
PENDANT/SURFACE MOUNTED LINEAR
INDUSTRIAL FIXTURE
Fire Alarm Symbols
Communications Symbols
S
Security Symbols
Access Symbols
RECESSED CEILING PAGING SPEAKER WITH GRILLE
EMERGENCY WALL PHONE ROUGH-IN ONLY. PROVIDE A 4"/16"
SQUARE OUTLET BOX WITH A SINGLE GANG DEVICE RING AND A
1" EMT CONDUIT TO NEAREST ACCESSIBLE CEILING (UNLESS
INDICATED OTHERWISE).
ADDRESSABLE FIRE ALARM CONTROL PANEL
COMBO SYNCHRONIZED SPEAKER/STROBE UNIT
ADDRESSABLE CONTROL MODULE
FACP
CM
HD
SD
HEAT DETECTOR
SMOKE DETECTOR
MANUAL PULL STATIONF
DC
CR
DOOR CHIME
CARD READER ROUGH-IN ONLY. PROVIDE A 4- 11/16"
SQUARE OUTLET BOX WITH A SINGLE GANG DEVICE
RING AND A 1" EMT CONDUIT TO NEAREST
ACCESSIBLE CEILING (UNLESS INDICATED
OTHERWISE).
F B
W
SECURITY TRAC DURESS CEILING SENSORD
R-59
CONTROL RELAY NUMBER
WIRE BASKET CABLE TRAY
SINGLE POLE SWITCH, 3'-8" AFF
WALL MOUNTED LINE VOLTAGE
OCCUPANCY SENSOR, 3'-8" AFFOS
LIGHTING FIXTURE SCHEDULE
FIXTURE
TYPE
LAMPING
MOUNTING MANUFACTURERLUMENS WATTSVOLTAGE
BALLAST/
DRIVER
DESCRIPTION
NUMBER LAMP
F01 RECESSED
CEILING
CORELITE # R2XWO2L351CUNV22X2583 277 2'x2' RECESSED LED FIXTURE WITH SMOOTH OPAL ACRYLIC LENS1 LED
F02 1664 2771 LED
F03 SURFACE WALL4462 2771 LED - -
- DIMMABLE
- DIMMABLE
PORTFOLIO # LD4A13DO1OTE -
ERW4A13835 - 4LW1L1
MCGRAW EDISION
#IST-F02-LED-E1-BL3-BZ-P
4" DIAMETER LED DOWNLIGHT FIXTURE WITH SIMI-SPECULAR ALZAK REFLECTOR.
WALL MOUNTED LED LIGHT FIXTURE WITH PHOTO CELL,
WET LOCATION LISTED
RECESSED
CEILING
FO4
EX-2
LED
LED -
EX-1 UNIVERSAL TOP,
END BACK
- 2771 LED - - MULE # ARS-A-1-R-AA SINGLE FACE LED EXIT SIGN FIXTURE WITH EXTRUDED ALUMINUM HOUSING
AND UNIVERSAL MOUNTING.
2786 SURFACE 28 - METALUX #
2-WNLED-LD4-28SL-UNX-L835-X-1
2' LED SURFACE MOUNTED FIXTURE WITH WRAP LENS
UNIVERSAL TOP,
END, BACK
277 - - MULE # ARS-A-2-R-AA DOUBLE FACE LED EXIT SIGN FIXTURE WITH EXTRUDED ALUMINUM HOUSING
AND UNIVERSAL MOUNTING
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of
Facilities
Management o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t 4 o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
BIDDING DOCUMENTS - FEBRUARY 22, 2019
VA CARES CONSOLIDATION
VAMC, PITTSBURGH, PA
CONNECTING BRIDGE
EG0-001
646CA2500.23
AuthorChecker
SYMBOLS & LIGHTING
FIXTURE SCHEDULE
VAPHS UNIVERSITY DRIVE
1 & 30
6.5
FE
D x.G x.J x.L x.5 x.6
E.7
EA
x.12
FO1
NE
FO1
NE
FO1 19
NE
FO1
NE
FO1
NE
FO1
NE
FO1
NE
FO1
NE
FO1
NE
FO1
NE
FO1
NE
FO1
NE
FO1
FO1
FO1
FO1
FO1
FO1
FO1
FO1
FO1
FO1
FO1
FO1 FO1 FO1 FO1 FO1 FO1
FO1 FO1
R-59
R-59
R-59
R-59
R-59
R-59
R-59
R-59
R-59
R-59
R-59
R-10
R-10
R-10
R-10
R-10
NE
R-10
FO2
R-59
FO2
NE
FO2
41R-59
FO2
R-59
FO2
NE
FO2
9 R-1011
NE
EX-1
EX-1
NE
EX-1 NE
EX-1
NE 19
EX-1 NE
EX-1
NE
EX-1
NE
EX-1
NE
EX-1
NE
EL2A-11
LS2HA-19
2HA-41
1 3
LP2-9
D
E
E.6
E.7 F
6.5
6.1
12.8 x.8x.7x.6x.5x.4 x.19x.18x.17x.16x.14 x.2 x.1 x.C
EA
x.L x.N x.P x.3
FO3
FO3
EX-2
NE
os
9FO4
FO1
R-10
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of
Facilities
Management o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t 4 o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
BIDDING DOCUMENTS - FEBRUARY 22, 2019
VA CARES CONSOLIDATION
VAMC, PITTSBURGH, PA
CONNECTING BRIDGE
EL1-101
646CA2500.23
AuthorChecker
BRIDGE LIGHTING PLAN
VAPHS UNIVERSITY DRIVE
1 & 30
Key Notes
1/8" = 1'-0"
BRIDGE LIGHTING PLAN
RELOCATE EXISTING STAIRWELL LIGHT FIXTURE. PROVIDE JUNCTION
BOXES AND ALL WIRING/ RACEWAY MODIFICATION AS REQUIRED.
COORDINATE EXACT LOCATION WITH RELOCATED CABINET HEATER
TO ENSURE PROPER CLEARANCES PER MANUFACTURER'S
RECOMMENDATIONS.
EXISTING LIGHT FIXTURES AND CONTROLS IN UNOCCUPIED SPACE
TO REMAIN AND BE MODIFIED TO ACCOMMODATE NEW CORRIDOR
WALL AND RELOCATION OF DUCT SHAFT. SHIFT EXISTING FIXTURES
THAT ARE IN CONFLICT WITH NEW PARTITIONS TO ADJACENT
CEILING TILES WITHIN THE UNOCCUPIED SPCE AND EXTEND
EXISTING CIRCUITS/CONTROLS TO NEW FIXTURE LOCATION.
PROVIDE NEW SWITCHING ADJACENT TO DOOR FOR CONTROL OF
EXISTING UNOCCUPIED SPACE LIGHTING. INTERCEPT & EXTEND
EXISTING BRANCH CIRCUIT WIRE TO CONTROL UNOCCUPIED AREA
EXISTING LIGHTING.
TO EXISTING BUILDING #1 LIFE SAFETY PANELBOARD EL2A CIRCUIT #
11 LOCATED APPROXIMATELY 100' AWAY. PROVIDE A 20 AMP SINGLE
POLE CIRCUIT BREAKER IN EXISTING SPACE.
WIRE TO EXISTING SPARE 20A-1P CIRCUIT BREAKER IN PANELBOARD
LP2 CIRCUIT #9 LOCATED IN BUILDING #1 ELECTRICAL ROOM 2W130.
CIRCUIT IS TO BE CONTROLLED VIA EXISTING SPARE RELAY #10 IN
LIGHTING CONTROL PANEL '2BT' WHICH IS ALSO LOCATED IN THE
SAME ELECTRICAL ROOM. PROVIDE ALL SOFTWARE MODIFICATIONS
AS REQUIRED TO EXSTING LIGHTING CONTROL PANEL FOR CONTROL
OF CORRIDOR LIGHTING FIXTURES. ROOM W2130 IS
APPROXIMATELY 220' AWAY.
WIRE TO EXISTING SPARE 20A-1P CIRCUIT BREAKER IN PANELBOARD
LS2HA CIRCUIT #19 LOCATED ON THE SECOND FLOOR OF BUILDING #
30 ELECTRICAL ROOM 2A109 APPROXIMATELY 180' AWAY.
WIRE TO EXISTING SPARE 20A-1P CIRCUIT BREAKER IN PANELBOARD
2HA CIRCUIT #41 LOCATED IN BUILDING #30 ELECTRICAL ROOM
2A123. CIRCUIT IS TO BE CONTROLLED VIA EXISTING SPARE RELAY #
59 IN THE LIGHTING CONTROL PANEL WHICH IS ALSO LOCATED IN THE
SAME ELECTRICAL ROOM. PROVIDE ALL SOFTWARE MODIFICATIONS
AS REQUIRED TO EXISTING LIGHTING CONTROL PANEL FOR
CONTROL OF CORRIDOR LIGHTING FIXTURES. ROOM 2A123 IS
APPROXIMATELY 100' AWAY.
EXTERIOR LIGHT FIXTURE TO BE SERVED VIA PANEL LP2 CIRCUIT 9
WITHOUT LIGHTING RELAY CONTROL. FIXTURE IS OPERATED FROM
DUSK TO DAWN VIA INTERNAL FIXTURE PHOTO CELL.
J
J
J
J
J
J
CABINET
HEATER
EXISTING BUILDING 1
2ND FLOOR
AREA W
EXISTING BUILDING 30
2ND FLOOR
W2D2-21
W2D2-23
D
E E.7
F
6.5
6.1
12.8 x.11x.10 x.8x.7x.6x.5x.4 x.19x.18x.17x.16x.14x.2 x.C
EA
x.D x.E x.F x.G x.J x.L x.N
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of
Facilities
Management o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t 4 o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
BIDDING DOCUMENTS - FEBRUARY 22, 2019
VA CARES CONSOLIDATION
VAMC, PITTSBURGH, PA
CONNECTING BRIDGE
EP1-101
646CA2500.23
AuthorChecker
BRIDGE POWER PLAN
VAPHS UNIVERSITY DRIVE
1 & 30
PROVIDE CONNECTION TO POWER OPERATED DOOR WITH CARD READER.
CARD READER SHALL ACTUATE THE DOOR FOR ENTRY FROM THE
UNSECURED SIDE.
NEW PANELBOARD W2D2 - 208/120V 3Ø,4W.
NEW PANELBOARD W2D1 - 208/120V 3Ø 4W.
NEW PANELBOARD W2E - 208/120V 3Ø 4W.
RELOCATED 3/4" EMT CONDUIT WITH 6 #12 AWG CONDUCTORS PROVIDE
JUNCTION BOXES AND ALL WIRING/RACEWAY MODIFICATIONS AS
REQUIRED. COORDINATE RELOCATOIN AND CIRCUIT OUTRAGE WITH
OWNER.
TO EXISTING PANELBOARD LS2LA, CIRCUIT #38 LOCATED APPROX. 300'
AWAY ON THE SECOND FLOOR OF BUILDING 30. PROVIDE #10 AWG WIRE
TO COMPENSATE FOR VOLTAGE DROP.
TO EXISTING PANELBOARD 2LC, CIRCUIT #42 LOCATED APPROX. 100'
AWAY ON THE SECOND FLOOR OF BUILDING 30.
FLOOR IN THIS AREA IS RAISED 14" AND IS TO RAMP DOWN FROM WEST TO
EAST. ALL NEW AND EXISTING ELECTRICAL SERVICES SHALL BE
COORDINATED WITH ALL OTHER TRADES TO MAINTAIN REQUIRED CEILING
HEIGHT.
HANDS FREE DOOR ACTUATOR EMPTY RACEWAY SYSTEM.
EXISTING CABINET HEATER TO BE REPLACED WITH NEW. INTERCEPT
EXISTING 120V 20AMP CIRCUIT CURRENTLY SERVING UNIT AND EXTEND TO
NEW UNIT AS REQUIRED.
PA AMPLIFIER. PROVIDE WALL-MOUNTED SHELF AT 6'-6" AFF AND OF
AMPLE DEPTH FOR NEW AMPLIFIER AND ASSOCIATED WIRING THAT
CONNECTS TO THE BACK OF THE UNIT. PROVIDE RECEPTACLE ADJACENT
TO SHELF AT 6'-6" AFF.
EXTEND EXISTING 120 VOLT, 20 AMP EMERGENCY LIFE SAFETY CIRCUIT
THAT PREVIOUSLY FED CORRIDOR RECEPTACLE (SEE ESD-801) TO NEW
RECEPTACLE FOR PA AMPLIFER AND POWERED DOOR CONNECTION.
PROVIDE GROUND CONNECTION TO NEAREST TELECOMMUNICATIONS
GROUNDING BUS, WIRE SIZE SHALL BE #10G.
PROVIDE GROUND BOND TO NEW STEEL STRUCTURE AT EACH END OF THE
BRIDGE. EXTEND 250KCMIL COPPER CONDUCTOR AND BOND TO EXISTING
BUILDING STRUCTURAL STEEL.
PROVIDE CONNECTION TO NEW POWERED DOOR OPERATOR TO BE
INSTALLED ON EXISTING DOOR. UTILIZE NEXT AVAILABLE SPARE CIRCUIT
FROM THE NEAREST LIFE SAFETY PANELBOARD. UPDATE PANELBOARD
SCHEDULE AS REQUIRED. REFER TO ARCHITECTURAL DRAWINGS FOR
PUSH PLATE ROUGH-IN LOCATIONS. PROVIDE/INSTALL ALL
INTERCONNECTING WIRING AS REQUIRED PER MANUFACTURER'S
INSTALLATION INSTRUCTIONS.
Key Notes
1/8" = 1'-0"
BRIDGE POWER PLAN
4#4/0+1#2G - 2 1/2"C
PB
PANELBOARD W2D1
208/120V, 3Ø, 4W
PANELBOARD W2D2
208/120V, 3Ø, 4W
PANELBOARD W2E
208/120V, 3Ø, 4W
PB
EXISTING
PANELBOARD W2F
208/120V, 3Ø, 4W
(TO REMAIN)
EXISTING
PANELBOARD W2E
208/120V, 3Ø, 4W
(42 POLE)
EXISTING
PANELBOARD W2D1
208/120V, 3Ø, 4W
(42 POLE)
EXISTING
PANELBOARD W2D2
208/120V, 3Ø, 4W
(36 POLE)
EXISTING DIST
BOARD DPW2
208/120V, 3Ø, 4W, 600A
(TO REMAIN)
4#3 +1#8G -1 1/4"C EXISTING 4 #3 +1#8G -1 1/4"C
EXISTING 4#4/0 +1#2G -2 1/2"C
EXISTING PANEL FEEDERS TO BE DE-
ENERGIZED AND REMOVED
FEEDER PULLBOX WITH SPLICE
CONNECTION AS APPLICABLE. SIZE BOX
AS PER NEC REQUIREMENTS (TYPICAL).
111222
EXISTING MAIN HEAD END
EQUIPMENT RACK LOCATED
IN THE BASEMENT MDF ROOM
4 CONDUCTOR 18 AWG - 3/4"C. EC TO
VERIFY CABLE REQUIREMENTS WITH
MANUFACTURER PRIOR TO ROUGH-IN.
BASEMENT
120V,20A
NE PWR
CKT # PER PLANS
S S ~
PA - 100W AMPLIFIER/ CABINET
BOGEN #C100 W/ UPS
4 CONDUCTOR 18 AWG - 3/4"C (TYP). EC
TO VERIFY CABLE REQUIREMENTS WITH
MANUFACTURER PRIOR TO ROUGH-IN.
TYPICAL CORRIDOR PA SPEAKER
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
FACP
FS FS
FSDHDTO NEXT
DEVICE
TO NEXT
DEVICE
CM SD SD
AS REQ'D
BY NFPA 72
FIRE ALARM RISER KEYNOTES (THIS DETAIL)
EXISTING ADDRESSABLE FIRE ALARM CONTROL PANEL. PROVIDE
ADDITIONAL ADDRESSABLE DEVICE CARDS AS REQUIRED. SYSTEM
MAY REQUIRE ADDITIONAL PROVISIONS TO BE MADE TO ADD CARDS.
OTHER EXISTING
DEVICES
OUTPUT
INPUT
NOTIFY NECESSARY STAFF
FOR RESPONSE FOR HEALTH
CARE AND HIGH RISE BUILDING
ONLY (ALARM SIGNAL MAY BE
DIFFERENT ON DIFFERENT
FLOORS)
NOTIFY FIRE
DEPARTMENT
INITIATE SUPERVISORY
SIGNAL TO A 24-HOUR
MANNED POINT FOR
IMMEDIATE RESPONSE
CLOSE ASSOCIATE
SMOKE BARRIER
DOORS ON THE
FLOOR
CLOSE DAMPERS
ON FAN PROXIMATE
TO DETECTOR.
SHUT DOWN AIR
HANDLER SERVED
BY THE DETECTOR
RECALL
ELEVATOR
OPEN LOCKED
EGRESS DOORS
ON FLOOR TO
FIRE ORIGIN
DUCT SMOKE DETECTOR
AREA SMOKE DETECTOR
DOOR RELEASE SMOKE DETECTOR
MANUAL PULL STATION
SPRINKLER WATERFLOW / PRESSURE
SWITCH
WATER CONTROL VALVE TAMPER
HIGH/LOW PRESSURE DRY - PIPE SPRINKLER
SYSTEM
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of
Facilities
Management o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t 4 o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
BIDDING DOCUMENTS - FEBRUARY 22, 2019
VA CARES CONSOLIDATION
VAMC, PITTSBURGH, PA
CONNECTING BRIDGE
EP5-101
646CA2500.23
AuthorChecker
ELECTRICAL SINGLE-LINE
DIAGRAMS
VAPHS UNIVERSITY DRIVE
1 & 30
N.T.S.
ELECTRICAL SINGLE-LINE DIAGRAM
PA SYSTEM RISER DIAGRAM - BUILDING 1
N.T.S.
TYPICAL FIRE ALARM CONNECTION
DIAGRAM
NTS3
FIRE ALARM SYSTEM MATRIX
KEYED NOTES :
1.
PROVIDE NEW PANELBOARDS TO REPLACE EXISTING PANELBOARDS WHICH ARE TO BE REMOVED. INSTALL NEW PANELBOARDS AND TAP EXISTING FEEDERS AS SHOWN. CLOSELY COORDINATE REQUIRED SHUT-DOWNS WITH THE VA TO MINIMIZE DOWNTIME OF EXISTING CIRCUITS. REFER TO PANELBOARD SCHEDULES FOR
ADDITIONAL INFORMATION.
2.
DISCONNECT EXISTING BRANCH CIRCUITS WHICH ARE TO REMAIN FROM THIS PANELBOARD AND REROUTE TO THE NEW PANELBOARD WITH THE SAME DESIGNATION (E.G. - CIRCUITS CURRENTLY FED FROM EXISTING PANELBOARD 'W2D2' WILL BE REFED FROM NEW PANELBOARD 'W2D2'). CLOSELY COORDINATE THIS WORK WITH THE VA TO MINIMIZE DISRUPTION TO EXISTING CIRCUITS AND CUT BRANCH CIRCUITS OVER ONE AT A TIME; NOTE THAT THESE CIRCUITS MAY EXTEND BEYOND THE RENOVATION AREA. AVOID CHANGING THE CIRCUIT NUMBER OF THE EXISTING CIRCUITS. SPLICE AND EXTEND EXISTING BRANCH CIRCUIT WIRING WITH SIMILAR
CONDUCTORS TO THE EXISTING CIRCUITS AS REQUIRED.
3.
AFTER ALL EXISTING BRANCH CIRCUITS WHICH ARE TO REMAIN HAVE BEEN RELOCATED TO THE NEW PANEL, DISCONNECT AND REMOVE EXISTING PANELBOARD.
DEMOLISH EXISTING FEEDER BACK TO THE POINT WHERE THE NEW FEEDER WAS TAPPED. REWORK TAPS AND PROVIDE PERMANENT SPLICES TO THE NEW FEEDERS.
CKT CIRCUIT DESCRIPTION TRIP POLESPOLES A
NOTES: FEED THROUGH LUGS. CIRCUITS NOTED AS "EXISTING LOADS" ARE TO BE RELOCATED FROM EXISTING PANEL "W2D1". MAINTAIN PREVIOUS CIRCUIT NUMBERS.
1 20 A 1
B C
TRIP
20 A
CIRCUIT DESCRIPTION CKT
3 20 A 1 1 20 A
5 20 A 1 1 20 A
7 20 A 1 1 20 A
9 20 A 1 1 20 A
11 20 A 1 1 20 A
13 20 A 1 1 20 A
15 20 A 1 1 20 A
17 20 A 1 1 20 A
19 20 A 1 1 20 A
21 20 A 1 1 20 A
23 20 A 1 1 20 A
25 20 A 1 2 30 A
27 20 A 1
29 15 A 2 2 40 A
31 --- ---
33 20 A 2 2 50 A
35 --- ---
37 30 A 3 3 30 A
39 --- --- --- ---
41 --- --- --- ---
16.5 17.2 17.7TOTAL LOAD:
51.4 KVA
TOTAL LOAD:
Branch Panel: W2D1 (NEW)
LOCATION: 2ND FL BLDG 1
SUPPLY FROM: DPW2
MOUNTING: SURFACE
ENCLOSURE: NEMA 1
VOLTS: 208Y/120V
PHASES: 3
WIRES: 4
A.I.C. Rating: 22,000
Mains Type: MCB
Mains Rating: 225A
MCB Rating: 225A-3P
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
.8 .8
.8 .8
.8 .8
.8 .8
.8 .8
.8 .8
.8 .8
.8 .8
.8 .8
.8 .8
.8 .8
.8 .8
.8 1.5
.8 1.5
.8 2.0
.8 2.0
1.0 2.5
1.0 2.5
2.5 2.5
2.5 2.5
2.5 2.5
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
CKT CIRCUIT DESCRIPTION TRIP POLESPOLES A
NOTES: CIRCUITS NOTED AS "EXISTING LOADS" ARE TO BE RELOCATED FROM EXISTING PANEL "W2D2". MAINTAIN PREVIOUS CIRCUIT NUMBERS.
1 20 A 1
B C
TRIP
20 A
CIRCUIT DESCRIPTION CKT
3 20 A 1 1 20 A
5 20 A 1 1 20 A
7 20 A 1 1 20 A
9 20 A 1 1 20 A
11 20 A 1 1 20 A
13 20 A 1 1 20 A
15 20 A 1 1 20 A
17 20 A 1 1 20 A
19 20 A 1 1 20 A
21 20 A 1 1 20 A
23 20 A 1 1 20 A
25 20 A 1 1 20 A
27 20 A 1 1 20 A
29 20 A 1 1 20 A
31 20 A 1 1 20 A
33 20 A 1 1 20 A
35 20 A 1 1 20 A
37 20 A 1 1 20 A
39 20 A 1 1 20 A
41 20 A 1 1 20 A
8.1 6.6 6.8TOTAL LOAD:
21 KVA
TOTAL LOAD:
Branch Panel: W2D2 (NEW)
LOCATION: 2ND FL BLDG 1
SUPPLY FROM: W2D1
MOUNTING: SURFACE
ENCLOSURE: NEMA 1
VOLTS: 208Y/120V
PHASES: 3
WIRES: 4
A.I.C. Rating: 22,000
Mains Type:
Mains Rating: 225A
MCB Rating: -----
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
REC - CORRIDOR
SPARE
SPARE
REC - LAB
REC - LAB
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
REC - LAB
REC - LAB
1.2 .5
.8 .8
.8 .8
.8 .8
.8 .8
.8 .8
.8 .8
.8 .8
.8 .8
.8 .8
.8 .8
.6 1.2
.8 1.2
SPARE
MLO
Branch Panel: W2E (NEW)
CKT CIRCUIT DESCRIPTION TRIP POLES
LOCATION: 2ND FL BLDG 1
SUPPLY FROM: DPW2
MOUNTING: SURFACE
ENCLOSURE: NEMA 1
VOLTS: 208Y/120V
PHASES: 3
WIRES: 4
A.I.C. Rating: 22,000
Mains Type: MCB
Mains Rating: 225A
MCB Rating: 225A-3P
POLES A
NOTES: CIRCUITS NOTED AS "EXISTING LOADS" ARE TO BE RELOCATED FROM EXISTING PANEL "W2E". MAINTAIN PREVIOUS CIRCUIT NUMBERS.
1 EXISTING LOADS 20 A 1 0.8 0.8
B C
TRIP
20 A
CIRCUIT DESCRIPTION
EXISTING LOADS
CKT
3 20 A 1 1 20 A
5 20 A 1 1 20 A
7 20 A 1 1 20 A
9 20 A 1 1 20 A
11 20 A 1 1 20 A
13 20 A 1 1 20 A
15 20 A 1 1 20 A
17 20 A 1 1 20 A
19 20 A 1 1 20 A
21 20 A 1 1 20 A
23 20 A 1 1 20 A
25 20 A 1 1 20 A
27 20 A 1 1 20 A
29 20 A 1 1 20 A
31 20 A 1 1 20 A
33 20 A 1 1 20 A
35 20 A 1 1 20 A
37 20 A 1 3 70 A EXISTING PANELBOARD W2F
39 20 A 2 - - ----
41 - - - - ----
--- 7.2
1.0 7.2
1.0 7.2
13.6 14.6 13TOTAL LOAD:
41.2 KVA
TOTAL LOAD:
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
EXISTING LOADS
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
0.8 0.8
0.8 0.8
0.8 0.8
0.8 0.8
0.8 0.8
0.8 0.8
0.8 0.8
0.8 0.8
0.8 0.8
0.8 0.8
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of
Facilities
Management o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t 4 o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
BIDDING DOCUMENTS - FEBRUARY 22, 2019
VA CARES CONSOLIDATION
VAMC, PITTSBURGH, PA
CONNECTING BRIDGE
EP6-101
646CA2500.23
AuthorChecker
PANELBOARD SCHEDULES
VAPHS UNIVERSITY DRIVE
1 & 30
CR
CM
CR
S
S
S
S
S
S
S
S
S S S
S
S
S
S
S
CM
F B
F B
F B
F B
F B
F B
F B
PB
F
EXISTING BUILDING 1
2ND FLOOR
AREA W
EXISTING BUILDING 30
2ND FLOOR
S
D
F B
D
F B
F B
F B
SD
SDSD
W W
W
W
SDSD
D
E
E.6
E.7 F
3.4
6.5
6.1
12.8 x.11x.10 x.8x.7x.6x.5x.4 x.19x.18x.17x.16x.14 x.2 x.C
EA
x.D x.E x.F x.G x.J x.L x.N
TW112
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of
Facilities
Management o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t 4 o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
BIDDING DOCUMENTS - FEBRUARY 22, 2019
VA CARES CONSOLIDATION
VAMC, PITTSBURGH, PA
CONNECTING BRIDGE
ET1-101
646CA2500.23
AuthorChecker
BRIDGE SYSTEMS PLAN
VAPHS UNIVERSITY DRIVE
1 & 30
3 - 4" EMT CONDUITS WITH DRAGWIRE FOR FUTURE TELECOMMUNICATION
CABLING.
RELOCATED SURFACE MOUNTED PAGING SPEAKER.
EXISTING SECURITY TRAC DURESS CEILING SENSOR TO BE
REMOVED FROM CEILING AND SUPPORTED ABOVE CEILING FOR
REINSTALLATION BY SECURTY VENDOR.
FIRE ALARM SPEAKER STROBE LOCATED IN BRIDGE SHALL BE
PROGRAMMED TO OPERATE FROM BOTH BUILDING #30 AND BUILDING #1
FIRE ALARM SYSTEMS.
TO NEW PA AMPLIFIER LOCATED IN ELECTRICAL ROOM.
TO NEAREST FIRE ALARM NOTIFICATION APPLIANCE PANEL AND AMPLIFIER
LOCATED IN BUILDING #1. CONTRACTOR TO PROVIDE A NEW BOOSTER
PANEL FOR APPLIANCE DEVICES IF REQUIRED. IF NEW PANEL IS ADDED,
PROVIDE SMOKE DETECTOR AT THIS LOCATION AS REQUIRED.
TO NEAREST FIRE ALARM NOTIFICATION APPLIANCE PANEL AND AMPLIFIER
LOCATED IN BUILDING #30. CONTRACTOR TO PROVIDE A NEW BOOSTER
PANEL FOR APPLIANCE DEVICES IF REQUIRED. IF NEW PANEL IS ADDED,
PROVIDE SMOKE DETECTOR AT THIS LOCATION AS REQUIRED.
TO NEAREST PAGING SYSTEM AMP LOCATED IN BUILDING #30.
PA 100W AMPLIFIER/ CABINET
120V 1 PHASE NE PWR,
BOGEN #C100
CONTACT: NICK WASKIEWICZ FROM DSX AT
412-848-8326
TO NEAREST EXISTING FIRE ALARM TERMINAL CABINET IN BUILDING #1.
PROVIDE NEW CABINET, EXPANSION CARDS, ETC. AS REQUIRED TO
SUPPORT NEW DEVICES.
TO NEAREST EXISTING FIRE ALARM TERMINAL CABINET IN BUILDING #30.
PROVIDE NEW CABINET, EXPANSION CARDS, ETC. AS REQUIRED TO
SUPPORT NEW DEVICES.
EXISTING TELECOMMUNICATIONS ROOM. PROVIDE FOUR (4) 4" SLEEVES
WITH FIRESTOPPING THROUGH WALL FOR FUTURE ACCESS TO NEW CABLE
TRAY.
LOCATE NEW FIRE ALARM PANELS WITHIN EXISTING ELECTRICAL ROOM
2W106. ROUTE NEW BACKBONE CABLING TO EXISTING FA PANEL LOCATED
IN ROOM 1C101 IN BUILDING 29.
Key Notes
1/8" = 1'-0"
BRIDGE SYSTEMS PLAN
NEW FIRE ALARM DEVICES TO BE SERVED FROM THE
EXISTING SIMPLEX BUILDING #30 AND BUILDING #1 FIRE ALARM
CONTROL PANELS. PROVIDE ALL NECESSARY SOFTWARE
MODIFICATION REQUIRED.
1.
General Notes
1 AMENDMENT 3 01-31-17
| ESD-801 - ELECTRICAL DEMOLITION PLAN |
| Sheets |
| EG0-001 - SYMBOLS & LIGHTING FIXTURE SCHEDULE |
| EL1-101 - BRIDGE LIGHTING PLAN |
| EP1-101 - BRIDGE POWER PLAN |
| EP5-101 - ELECTRICAL SINGLE-LINE DIAGRAMS |
| EP6-101 - PANELBOARD SCHEDULES |
| ESD-801 - ELECTRICAL DEMOLITION PLAN |
| ET1-101 - BRIDGE SYSTEMS PLAN |
| EG0-001 - SYMBOLS & LIGHTING FIXTURE SCHEDULE |
| Sheets |
| EG0-001 - SYMBOLS & LIGHTING FIXTURE SCHEDULE |
| EL1-101 - BRIDGE LIGHTING PLAN |
| EP1-101 - BRIDGE POWER PLAN |
| EP5-101 - ELECTRICAL SINGLE-LINE DIAGRAMS |
| EP6-101 - PANELBOARD SCHEDULES |
| ESD-801 - ELECTRICAL DEMOLITION PLAN |
| ET1-101 - BRIDGE SYSTEMS PLAN |
| EL1-101 - BRIDGE LIGHTING PLAN |
| Sheets |
| EG0-001 - SYMBOLS & LIGHTING FIXTURE SCHEDULE |
| EL1-101 - BRIDGE LIGHTING PLAN |
| EP1-101 - BRIDGE POWER PLAN |
| EP5-101 - ELECTRICAL SINGLE-LINE DIAGRAMS |
| EP6-101 - PANELBOARD SCHEDULES |
| ESD-801 - ELECTRICAL DEMOLITION PLAN |
| ET1-101 - BRIDGE SYSTEMS PLAN |
| EP1-101 - BRIDGE POWER PLAN_updated |
| Sheets |
| EP1-101 - BRIDGE POWER PLAN |
| ET1-101 - BRIDGE SYSTEMS PLAN |
| EP5-101 - ELECTRICAL SINGLE-LINE DIAGRAMS |
| Sheets |
| EG0-001 - SYMBOLS & LIGHTING FIXTURE SCHEDULE |
| EL1-101 - BRIDGE LIGHTING PLAN |
| EP1-101 - BRIDGE POWER PLAN |
| EP5-101 - ELECTRICAL SINGLE-LINE DIAGRAMS |
| EP6-101 - PANELBOARD SCHEDULES |
| ESD-801 - ELECTRICAL DEMOLITION PLAN |
| ET1-101 - BRIDGE SYSTEMS PLAN |
| EP6-101 - PANELBOARD SCHEDULES |
| Sheets |
| EG0-001 - SYMBOLS & LIGHTING FIXTURE SCHEDULE |
| EL1-101 - BRIDGE LIGHTING PLAN |
| EP1-101 - BRIDGE POWER PLAN |
| EP5-101 - ELECTRICAL SINGLE-LINE DIAGRAMS |
| EP6-101 - PANELBOARD SCHEDULES |
| ESD-801 - ELECTRICAL DEMOLITION PLAN |
| ET1-101 - BRIDGE SYSTEMS PLAN |
| ET1-101 - BRIDGE SYSTEMS PLAN_updated |
| Sheets |
| EP1-101 - BRIDGE POWER PLAN |
| ET1-101 - BRIDGE SYSTEMS PLAN |
File details come from the government source that posted it.