36C10F19R0003-0005002.pdf
PDF 686 KB Posted
- Solicitation number
- 36C10F19R0003
About this file
36C10F19R0003 0005 AS1-101 - FLOOR PLANS.pdf
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DNUP
DN
UP
DN
UP
TOILET
FLOOR PLAN
GENERAL NOTES
1. SEE DRAWING AS8-102 FOR PARTITION TYPES.
PARTITION RATING LEGEND
S S S S S
1 HOUR FIRE HARZARDOUS AREA
2 HOUR FIRE SHAFT
1 HOUR SMOKE BARRIER SMOKE ZONE
2 HOUR FIRE/SMOKE SMOKE ZONE
3.4
F
F
E E.6DC.6 E.7
x.Gx.G x.J
AS3-101
x.L x.N
AS5-102
AS5-102
AS5-103
6.5
AS3-101
AS3-101
x.4 x.5 x.6 x.7 x.11 x.1 x.1 x.2 x.14 x.15 x.16 x.17
AS5-103
x.18 x.19 x.20
AS3-1012
8' -0
8'-0"
8'-8 3/4"
24'-9 3/8" 23'-4"
'-1
/8
6.1
RAMP DN
34'-2"
8'-7 1/4"
R A
M P
D N
'-3
9"
INFILL FLOOR OPENING - SEE
STRUCTURAL DRAWINGS
ROOF BELOW
1197'-6 5/8" +/-
1195'-10 1/8" +/-
LANDING 2
1193'-1 3/8"
2nd FLOOR
AREA W
1197'-6 5/8"
2nd FLOOR
1204'-10 3/4"
BRIDGE LEVEL
1197'-6 5/8"
2nd FLOOR
1197'-6 5/8" +/-
LANDING 1
SECOND FLOOR
BUILDING 30
8' -0
M
IN
EXISTING AREA W
EXISTING
BUILDING 1
EXISTING
BUILDING 30
AS3-101
9' -0
'-0
'-0
'-0
10"
34'-11 1/2"1'-8"
'-8
/8
'-1
/4
EA
x.Cx.C
'-4
/4
AS3-101
1' -0
10"
12.8
8' -7
/4
1:20
1:
AS5-102
AS1-101
AS5-101
x.F x.E x.D
8' -0
M
IN
6' -0
"4' -0
1194'-3 3/8"
LANDING 3
AS5-102
RAMP DN
1:20
AS5-101
A -0
A-02
A -0
A -0
1 1
1'-0"
HANDRAIL
EXTENSION
1' -0
H A
N D
R A
IL
E
X T
E N
S
IO
N
CONT.
ALUM.
HANDRAIL
AS3-101
1'-0"
HANDRAIL
EXTENSION
BOTH SIDES
ALUM. HANDRAILS AT
34" AFF, BOTH SIDES
A -0
INFILL WINDOW OPENING; MATCH EXISTING
CONSTRUCTION
NEW PARAPET, ROOFING INSULATION,
MEMBRANE, AND FLASHING. REFER TO
SECTION DETAIL.
AS5-101
A-09
AS1-102
ELECTRIC
GA146
TELECOM
2W112
LINEAR
WORK
C2003
EXISTING
ELEVATOR
LOBBY
2A143
CORRIDOR
GA153
EXISTING
VESTIBULE
2A145
EXISTING
ELEVATOR
LOBBY
3A146
MECHANICAL
ROOM
GA155
AS8-101
RESEARCH
LAB
3A143
OFFICE
2W146
MIN.
3'-8"
5' -0
7'-0"
6' -0
AS1-102
5'-0"
5' -0
AS3-1018
STAFF M
TOILET
2W122
STAFF W
TOILET
2W123
OFFICE
2W144
9 9 9
AS8-101
15 1313131313131313
AS8-101
6' -0
4'
-6
6' -0
4'
-6
6' -0
4'
-6
6' -0
4'
-6
6' -0
AS8-101
1197'-6 5/8"
2nd FLOOR
12'-2 1/2"
1'-0"
HANDRAIL
EXTENSION
BOTH SIDES
WD1
WD1
WD1
WD1
WD1
7'-6"
AS0-001
AS9-341
A-15
CORRIDOR
C2W3
CORRIDOR
C2W3
TELEHEALTH
EDUCATION
TRAINING
2W109
TELEHEALTH
EDUCATION
TRAINING
2W110
CORRIDOR
2W113
ELEC
2W106
STAFF
BREAK
2W108
LOCKER
AREA
2W111
SEE DRAWING AS9-341 FOR
CONTINUATION OF PLAN
EXISTING TO REMAIN
NEW CONSTRUCTION
1 KEYNOTE
EXISTING DOOR
NEW DOOR
FLOOR PLAN LEGEND
PATTERN DENOTES RAISED STRUCTURAL
CONCRETE FLOOR PANEL ON MTL FRAMING.
REFER TO FINISH PLAN FOR FLOORING
MATERIAL.
AS5-102
x.1 x.2
AS5-103
EA
12.8
EA
7'-6 3/4"
4 4
8" 8"
7/
8"
1' -0
3"
1' -0
R A
M P
FOAMED INSULATION CORE - HORIZ. METAL
WALL PANELS -INSTALL OVER AIR/VAPOR
BARRIER ON 5/8" GYP. SHEATHING
EXPANSION JOINT
EXTRUDED ALUMINUM
TOOTH-IN BRICK W/ EXISTING.
RECONSTRUCT EXTERIOR WALL
TO MATCH EXISTING
RIGID INSULATION
METAL FRAMING
EXISTING GWB ON MTL. FRAMING
- PATCH & REPAIR AS REQ'D DUE
TO NEW CONSTRUCTION
ALUM
HANDRAIL, TYP.
WALL
EXPANSION
COVER
AS5-102
2" EXPANSION
JOINT COVER
9"
STRUCTURAL CONCRETE PANELS
ON COLD FORM METAL FRAMINGEXISTING WALL
TOOTH-IN BRICK W/ EXISTING.
RECONSTRUCT EXTERIOR WALL
TO MATCH EXISTING
6 3/8"
8'-0"
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of
Facilities
Management o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t 4 o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
BIDDING DOCUMENTS - FEBRUARY 22, 2019
VA CARES CONSOLIDATION
VAMC, PITTSBURGH, PA
CONNECTING BRIDGE
AS1-101
646CA2500.23
AuthorChecker
FLOOR PLANS
VAPHS UNIVERSITY DRIVE
1 & 30
1/8" = 1'-0"
SECOND FLOOR BRIDGE PLAN
1/2" = 1'-0"
ENLARGED PLAN @ BUILDING 1
PLAN KEY NOTES
Circle Keynote Description
1 NEW 2 HOUR WALL WITH 90 MINUTE DOUBLE EGRESS
DOORS. PROVIDE THRESHOLD.
2 EXPANSION JOINT WITH COVER
3 PAINTED STEEL RAILING AND GUARD RAIL WITH GATE
4 NEW 1 HOUR RATED PARTITION
5 NEW PAINTED DRYWALL COLUMN ENCLOSURE.
6 NEW RETRACTABLE LADDER.
7 NEW EXTERIOR LOUVER ABOVE, SEE ELELVATION
8 COMPOSITE SLAB TO FOLLOW RAMP SLOPES AND LANDINGS
9 FLOOR FINISH TO BE RESTORED TO "LIKE NEW" FINISH
AFTER PARTIAL DEMOLITION
10 NEW 2 HOUR FIRE WALL. CONTINUITY OF STAIRWELL
ENCLOSURE TO REMAIN FROM FLOOR BELOW.
11 ALIGN NEW PARTITION WITH EXISTING PARTITIONS
12 NEW 90 MINUTE DOOR INTO STAIRWELL; PROVIDE
THRESHOLD.
13 PATCH WINDOW OPENING WHERE WINDOW BLINDS AND
STOOL WERE REMOVED
14 RELOCATED FIRE EXTINGUISHER
15 FIRE EXTINGUISHER AND CABINET
16 NEW ALUMINUM WINDOWS
17 NEW 1 HR WALL WITH 45 MINUTE DOOR.
1 AMENDMENT NO. 5 03 MAY 2019
| Sheets |
| AS1-101 - FLOOR PLANS |
| AS8-101 - DOOR & WINDOW TYPES, DETAILS, LADDER DETAILS |
File details come from the government source that posted it.