About this file

This architectural drawing sheet (A-700.2) prepared by Stantec provides detailed specifications and construction details for doors and louvers for the Immokalee Sports Complex Phase 1A & 1B project, a Collier County, Florida construction initiative (IFB 26-8703). The document specifies door types, frame requirements, hardware sets, and louver specifications for the field restroom facility and associated structures. Door types include hollow metal frames with single and double configurations, roll-up overhead doors, and exterior doors requiring fire ratings in specific applications. The drawing details five scheduled doors (numbered 101-104B) for various spaces including men's and women's restrooms, janitorial closet, and storage areas, with heights ranging from 2'–6" to 12'–0", all featuring hollow metal or roll-up construction. Hardware sets HW-1 and HW-2 are specified for public restroom exterior doors and storage/service exterior doors respectively, including Grade 1 cylindrical lever locksets, heavy-duty hinges, closers, kick plates, thresholds, weather seals, and door sweeps. One 18"×18" louver is scheduled with galvanized steel construction and motorized operation per NOA 23-1129.09. The drawing references multiple product approvals (NOA designations) and construction standards including SDI compliance, 2023 Florida Building Code adherence, corrosion-resistant materials, and Miami-Dade storm-resistance requirements for exterior components.

The specifications establish strict material and construction requirements including G60 galvanized or A60 galvaneal steel doors and frames minimum 16 gauge thickness, two-coat rust inhibitive primer with finish coats of Sherwin-Williams Industrial Enamel, fully welded frames for new construction, and specialized corrosion-resistant materials for coastal applications. All exterior rolling doors require product approval documentation certifying compliance with current Florida Building Code requirements. Louvers must utilize storm-resistant extruded aluminum with anodized protective coating, specifically acceptable products including Ruskin Hurricane Louvers model ELF6375DXD with two-coat baked enamel polyester finish. Steel frames in masonry construction require full grouting with minimum three anchors per jamb, while frames in stud construction require spot grouting at anchor locations. All metal door frames must include holes and wire ways for electrification of hinges and hardware. The drawing indicates this is one component of the comprehensive $6.24 million Immokalee Sports Complex project with a substantial completion requirement of 180 calendar days from Notice to Proceed and final completion within 30 days thereafter.

View the file

Other files

File Type Posted
26-8703_Sheet_A-711.pdf PDF
26-8703_Sheet_A-602.pdf PDF
26-8703_Sheet_A-101.2.pdf PDF
26-8703_Phase_1B_Sheet_C109.pdf PDF
26-8703_Phase_1B_Sheet_C106.pdf PDF
26-8703_Phase_1A_Sheet_C508.pdf PDF
26-8703_Phase_1A_Sheet_C500.pdf PDF
26-8703_Phase_1A_Sheet_C109.pdf PDF
26-8703_Phase_1A_Sheet_C106.pdf PDF
26-8703_Exhibit_K_SFWMD_ERP_Permit.pdf PDF
26-8703_Bid_Schedule_(rev._1).xlsx XLSX spreadsheet
26-8703_Solicitation_(rev._1).pdf PDF
26-8703_Pre-Bid_Meeting_Audio.MP3 MP3 file
26-8703_Geotechnical_Report.pdf PDF
PO_Terms_and_Conditions_Rev.3.pdf PDF
Construction_Services_Agreement_2025_Template_ver_3_with_Exhibits.pdf PDF
26-8703_Supplemental_Qualifications.pdf PDF
26-8703_Scope_of_Work_Phase_1A_&_1B.pdf PDF
26-8703_Exhibit_M3_Phase_1A_Landscape_Architecture_Plans.pdf PDF
26-8703_Exhibit_M2_Phase_1A_Civil_Engineering_Plans.pdf PDF
26-8703_Exhibit_M1_Phase_1A_Keysheet.pdf PDF
26-8703_Exhibit_J3_Phase_1B_Technical_Specifcations_Part_2.pdf PDF
26-8703_Exhibit_J2_Phase_1B_Technical_Specifications_Part_1.pdf PDF
26-8703_Exhibit_J1_Phase_1A_Technical_Specifications.pdf PDF
26-8703_Exhibit_N_-_EHS_Contractor_Requirements_Master_2021_rev.pdf PDF
26-8703_Exhibit_M10_Phase_1B_Landscape_&_Irrigation_Plans.pdf PDF
26-8703_Exhibit_M9_Phase_1B_Structural_Plans.pdf PDF
26-8703_Exhibit_M8_Phase_1B_Electrical_Plans.pdf PDF
26-8703_Exhibit_M7_Phase_1B_Mechanical_&_Plumbing_Plans.pdf PDF
26-8703_Exhibit_M6_Phase_1B_Architecture_Plans.pdf PDF
26-8703_Exhibit_M5_Phase_1B_Civil_Engineering_Plans.pdf PDF
26-8703_Exhibit_M4_Phase_1B_Keysheet.pdf PDF
Construction_Bid_Instructions.pdf PDF
26-8703_Bid_Schedule.xlsx XLSX spreadsheet
26-8703_Solicitation.pdf PDF
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T. O. SLAB

EL. 0' - 0"

T. O. BEAM

EL. 8' - 3"

L2

1'-6"

L1

3'-0"

TYPE G

SINGLE METAL FENCING

DOOR

FINISH FLOOR

DOOR FRAME TYPES

0'-1" SEE

SCHED

0'-1"

S E

E S

C H

E D

TYPE DGTYPE ROLL UP

SEE

SCHED

S E

E S

C H

E D

TYPE FP

SINGLE DOOR

HOLLOW METAL FRAME

0'-2" SEE

SCHED

0'-2"

S E

E S

C H

E D

OVERHEAD ROLL UP DOOR DOUBLE METAL FENCING

DOOR

0'-1" SEE

SCHED

0'-1"

S E

E S

C H

E D

TYPE DFP

DOUBLE DOOR

HOLLOW METAL FRAME

0'-2" SEE

SCHED

0'-2"

S E

E S

C H

E D

STEEL DOOR AND FRAME NOTES:

COMPLY WITH SDI STANDARDS. USE OF STEEL DOORS AND

FRAMES ARE LIMITED TO FIRE-RATED APPLICATIONS AND

SERVICE AREAS ONLY.

1. PROVIDE TWO COATS OF RUST INHIBITIVE PRIMER ON ALL

SURFACES OF METAL DOORS AND FRAMES AND PRIOR TO

INSTALLATION, THEN 2 FINISH COATS OF SW INDUSTRIAL

ENAMEL ON EXPOSED METAL SURFACE.

2. PROVIDE CORROSION RESISTANT COATING:

A. STEEL DOORS AND FRAMES SHALL BE G60 GALVANIZED

OR A60 GALVANNEAL MATERIAL AND FACTORY PRIMED.

B. WIPE COAT GALVANIZED STEEL (WCGS) PRODUCTS MAY

NOT BE USED.

2. DOORS AND FRAMES SHALL BE NOT LESS THAN 16 GAUGE

THICK.

3. FRAMES IN MASONRY CONSTRUCTION SHALL BE FULLY

GROUTED. PROVIDE NOT LESS THAN 3 ANCHORS AT EACH

JAMB.

4. FRAMES IN STUD CONSTRUCTION SHALL BE SPOT

GROUTED AT EACH ANCHOR, MIN 3 PER JAMB.

5. ALL STEEL FRAMES ARE TO BE FULLY WELDED FOR NEW

CONSTRUCTION. KNOCK-DOWN (KD) FRAMES MAY BE USED

ONLY FOR RETROFIT INSTALLATIONS.

6. PROVIDE FIRE RATED UNITS WHERE REQUIRED TO

MAINTAIN INTEGRITY OF RATED ASSEMBLIES.

7. ALL METAL DOOR FRAMES SHALL HAVE HOLES AND

ACCESSIBLE WIRE WAYS TO PERMIT ELECTRIFICATION OF

HINGES AND DOOR OR FRAME MOUNTED HARDWARE.

OVERHEAD COILING DOORS NOTES:

A. GENERAL: ALL DOOR COMPONENTS INCLUDING

FASTENERS, SLATS, GUIDES, AND HOUSING SHALL BE

CONSTRUCTED OF NON-CORRODING MATERIAL LIMITED TO

STAINLESS STEEL, PAINTED, OR ANODIZED ALUMINUM, OR

FACTORY PRIMED GALVANIZED STEEL.

1. SWIMMING POOL AREAS, CORROSIVE MATERIAL HANDLING

AREAS, AND LOCATIONS WITHIN 1 MILE OF COASTLINE: ALL

STAINLESS-STEEL MATERIALS INCLUDING SLATS, GUIDES,

CHAINS, HOUSING, OPERATING MECHANISMS, AND

FASTENERS.

2. OTHER LOCATIONS: GALVANIZED STEEL OR OTHER

APPROVED CORROSION RESISTANT MATERIALS LISTED

ABOVE.

B. PROVIDE SUBMITTAL CERTIFYING THE UNITS AND

ATTACHMENT FASTENERS MEET OR EXCEED CURRENT FBC

REQUIREMENTS.

EXTERIOR DOORS NOA APPROVALS:

NOA 23-0821.19

STEEL CRAFT H SERIES DOUBLE FLUSH OUTSWING

COMMERCIAL STEEL DOOR.

NOA 23-0821.18

STEEL CRAFT H SERIES SINGLE FLUSH OUTSWING

STEEL DOOR.

NOA 23-1129.09

SERIES 3400 STEEL ROLL-UP DOOR BY JANUS

INTERNATIONAL GROUP, LLC

LOUVER NOTES:

1. ALL LOUVERS SHALL BE STORM RESISTANT

EXTRUDED ALUMINUM WITH ANODIZED OR

APPROPRIATE PROTECTIVE COATING.

MILL-FINISH UNITS OR STAMPED METAL

LOUVERS ARE NOT ALLOWED. ACCEPTABLE

PRODUCTS INCLUDE BUT ARE NOT LIMITED

RUSKIN "HURRICANE LOUVERS".

MANUFACTURER: RUSKIN OR APPROVED EQUAL

MODEL: ELF6375DXD

APPROVALS: MIAMI-DADE NOA APPROVAL 23-1116.05

FINISH: 2 COAT BAKED ENAMEL POLYESTER

FINISH. COLOR TO BE SELECTED FROM

MANUFACTURER COLOR CHART.

0'-2"

SEE PARTITION PLAN FOR

WALL TYPES

SCHEDULED DOOR

S

S

HOLLOW METAL FRAME - JAMB

JAMB ANCHOR BOTH SIDES -

TYP

GROUT FRAME SOLID AT ALL

EXTERIOR DOORS AND DOORS

OVER 3'-0" IN WIDTH

ROOM SIDE

PUBLIC SIDE

HOLLOW METAL FRAME - HEAD

SCHEDULED DOOR

JAMB BEYOND

GROUT FRAME SOLID AT ALL

EXTERIOR DOORS AND DOORS

OVER 3'-0" IN WIDTH

SEE PARTITION PLAN FOR

WALL TYPES

CONTINUOUS BOND BEAM

PUBLIC SIDE ROOM SIDE

0' -2

CONC.

LINTEL

17"

STUCCO

D O

O R

O P

E N

IN

G H T

0'-2"

12"

BOTTOM OF TRUSS

REFER TO SECTIONS

COIL HOUSING

3/16" END

MOUNTING PLATE

MOTOR

MOUNT PLATE

MOTOR

COIL

ROLLING DOOR

GUIDEWAY

AUXILARY

HAND CHAIN

0'-3"

NOTE:

PRODUCT APROVAL (N.O.A.)

REQUIRED FOR ALL EXTERIOR

ROLLING DOORS

EXTERIOR INTERIOR

0'-4"

STUCCO FINISH

SEALANT

4" X 4" X 3/8", 4' LONG

STL. CORNER GUARD

D O

O R

O P

N 'G

W

ID

T H

0'-3" 0'-1" 0'-2"

3" X 3" X 3/16"

3/16" STL. BRACKET

PLATE ABOVE

2X3X3/16"

A BOLTS

0'-8" 0'-6"

NOTE:

PRODUCT APROVAL (N.O.A.)

REQUIRED FOR ALL

EXTERIOR ROLLING DOORS

0'-1"

SL. 1/2"/FT

WALL

EXTERIOR INTERIOR

8" CONC. LINTEL

ALUM. DRAINABLE LOUVER BLADE

2" x 3" x 1/4" MOUNTING

ANGLES. GALV. STL.

CONC. SILL

EXTERIOR INTERIOR

ALUM. HEAD FRAME

SEALANT, BACKER ROD

STUCCO STOP

STUCCO

EXTR'D GUTTER IN

ALUM. JAMB BEYOND

ALUM. SILL FRAME

SEALANT, BACKER ROD

TOOL SEALANT JT.

ALUM. SILL FLASHING

7"x2"x1/16"

ALUM. DRAINABLE LOUVER

BLADE

EXTR'D GUTTER IN

ALUM. JAMB BEYOND

2" x 3" x 1/4" MOUNTING

ANGLES. GALV. STL.

INTERMEDIATE

LOUVER SUPPORT

POST

ALUM. JAMB FRAME

8" CIP CONC. OR CMU F.C

2" x 3" x 1/4" MOUNTING

ANGLES. GALV. STL.

JAMB

HEAD

SILL

INTERMEDIATE LOUVER

BLADE SUPPORT POST

(AS REQ'D)

GUTTER

ALUM. DRAINABLE LOUVER BLADE

GALV. STL. SHT. MTL.

CONNECTOR SLEEVE

FOR DAMPER OR

DUCT

GALV. STL. SHT.

MTL. CONNECTOR

SLEEVE FOR

DAMPER OR DUCT

RUSKIN LOUVER FINISH:

POWDER COAT PAINT ( TO MATCH WALL FINISH)

M A

X

M A

X

SEALANT, BACKER ROD

STUCCO STOP

STUCCO

M A

X

SET ANCHORS IN SEALANT AND SEAL

ANCHOR HEADS IN COMPATIBLE

SEALANT TO BE TOOLED PROPERLY

CEMENTITIONS AIR AND

WEATHER BARRIER

TILE

INTERMEDIATE

LOUVER SUPPORT

POST

SILL

GALV. STL. SHT.

MTL. CONNECTOR

SLEEVE FOR

DAMPER OR DUCT

8" MR GWB

THIN SET OR

MORTAR BED

SHLUTER TILE EDGING

TRIM

Hardware Set HW-1

Public Restroom Exterior Door

Qty.Hardware item Suggested requirement 3 Hinges 4-1/2 × 4-1/2-inch heavy-duty ball-bearing hinges; stainless steel; non-removable pins; use only hinge type and attachment permitted by NOA

1 LocksetGrade 1 cylindrical lever lockset, storeroom function; keyed exterior lever and always-free egress from interior

1 Cylinder Owner-standard interchangeable-core or conventional cylinder;

coordinate keyway and keying with Collier County

1 Door closer Heavy-duty surface closer, barrier-free adjustable;

parallel-arm mounting where required by outswing condition

1 Kick plate10-inch-high stainless-steel kick plate on push side;

coordinate fasteners so door skin is not compromised

1 Wall or floor stop Heavy-duty stop selected to suit actual wall and floor conditions

1 Threshold Approved threshold corresponding to the selected NOA configuration; accessible profile, maximum 1/2-inch height

1 set Weather seals Head and jamb weatherstripping compatible with the

NOA assembly

1 Door sweep Exterior-grade sweep or bottom seal compatible with the approved threshold

1 Drip cap Aluminum or stainless-steel rain drip at frame head where opening is not protected by roof overhang

As required Silencers Frame silencers only where compatible with required perimeter seals

Hardware Set HW-2

Storage/Service Exterior Door

Qty.Hardware item Suggested requirement 3 Hinges 4-1/2 × 4-1/2-inch heavy-duty ball-bearing hinges; stainless steel; non-removable pins;

approved attachment per NOA

1 Lockset Grade 1 cylindrical lever lockset, storeroom function

1 Cylinder Owner-standard cylinder; coordinate keyway and keying with

Collier County

1 Door closerHeavy-duty surface closer, parallel arm where appropriate

1 Kick plate10-inch-high stainless-steel kick plate

1 Wall or floor stop Heavy-duty stop selected for field conditions

1 Threshold NOA-approved threshold configuration; accessible profile where on an accessible route

1 set Weather seals Continuous head and jamb weatherstripping

1 Door sweep Exterior-grade bottom sweep or seal

1 Drip cap Provide where the opening is exposed to weather

DOOR AND LOUVER

SCHEDULES

DOOR NO. ROOM NAME KEY NOTES

FIRE

LABEL

DOOR FRAME

TYPE WIDTH HEIGHT THK

NO. OF

PANELS MATERIAL FINISH

PANEL DIMENSIONS

HEAD JAMB FINISH

DETAILS

LOUVER SCHEDULE

DOOR SCHEDULE

104A

104B

MEN'S RESTROOMS

WOMEN'S RESTROOMS

JANITORIAL CLOSET

STORAGE

STORAGE

FP

FP

FP

FP

ROLL UP

3'-0"

3'-0"

2'-6"

3'-0"

12'-0"

7'-0"

7'-0"

7'-0"

7'-0"

6'-10"

0'-1 3/4"

0'-1 3/4"

0'-1 3/4"

0'-1 3/4"

HM PT PT

HM PT PT

HM PT PT

HM PT PT LOUVER SIZE 18"x18"

PTGALV. STL.10'-2" PT NOA 231129.09/ MOTORIZED

NOA 23-0821.14

NOA 23-0821.14

NOA 23-0821.14

NOA 23-0821.14

HRDWR.

SET

3" = 1'-0"A-700.2

2 HM FRAME - DOOR JAMB @ CMU WALL

3" = 1'-0"A-700.2

1 HM FRAME - DOOR HEAD @ CMU WALL

1 1/2" = 1'-0"A-700.2

7 ROLLING DOOR - DOOR JAMB

1 1/2" = 1'-0"A-700.2

6 ROLLING DOOR - DOOR HEAD

LOUVER - HORIZ. CMU HEAD, JAMB, SILL

A-700.2

3" = 1'-0"

LOUVER - HORIZ. SILL

A-700.2

8A

3" = 1'-0"

A

T T

E N

T

IO

N

T h e s e d ra w in g s m a y i n c lu d e i n fo rm a ti o n p ro v id e d b y o th e rs

S ta n te c h a s n o t v e ri fi e d th e a c c u ra c y a n d /o r c o m p le te n e s s o f th is in fo rm a ti o n a n d s h a ll n o t b e r e s p o n s ib le f o r a n y e rr o rs o r o m is s io n s w h ic h m a y b e in c o rp o ra te d h e re in a s a r e s u lt

A-700.2

2026-11-10T13:42:07-0500
Elvira C Freire Santamaria
I have reviewed this document

File details come from the government source that posted it. Updated .