This is an EVAPCO Equipment Production Order (Confidential) documenting manufacturing specifications for cooling tower equipment ordered by American Combustion. The order, issued October 6, 1999, with a scheduled completion date of November 12, 1999, specifies the production of six pieces of equipment featuring dual tag numbers CT-1, CT-2, CT-1A, CT-1B, CT-2A, and CT-2B.

The equipment includes eight 5-60 PA gallon screens or eight 5-69 PA pressure swing transfer fans; four 132-inch, 7-blade, 380-millimeter fans with 12-degree pitch and RAO 2 11/16 bearing assemblies; and four cadmium-plated fan bushings. The cooling tower units feature 24x36-inch pans with plenum, four 10-inch outlets, and eight 35-inch and 60-inch strainers. The casings contain four 12x18/4-layer configurations with 24 nozzles, filled in four layers with pointed and alternative tips using blocks 107 and 71 in specified quantities. The fan motor specifications include four 60-horsepower units operating at 230-460 volts, 60 hertz, 3-phase at 1800 RPM. Detailed drive configurations include four 6B7.6 and 6B 38.0 (AL) drivers with 13-22SP and 13-222P designations, plus associated bushings and belts. Accessories encompass remote sumps, electric level controls, ladders, jib booms, vibration switches, flange connections, stainless steel components, and steam coils. Remarks specify 10-inch BFN grooved inlets, 10-inch flanged bottoms, external service platforms with ladder and safety cage, three-foot fan cylinder extensions, and ground-polished steel fan shafts with galvanized fan screens and bolt provisions for helicopter lifting equipment.

View the file

Other files

File Type Posted
Attachment 16 M03-vfd plan-BEPVFD.pdf PDF
Attachment 10 - 75D-07.0-04 EMS Document EHS Contractor Requirements.pdf PDF
Attachment 29 Chiller Plan Upgrade M-1_recover.pdf PDF
Attachment 3 - Statement of Work - Cooling Towers Revision 02 Amendment 0002.pdf PDF
Attachment 28 Chiller Plan Upgrade M-1_120508 Model (1).pdf PDF
Attachment 14 Evapco performance data.pdf PDF
Attachment 18 Plate and Frame HX Information.pdf PDF
Attachment 11 - 75D-04.0-11 Fall Protection Procedure.pdf PDF
Attachment 8 - Site Visit Sign In Sheet.pdf PDF
Attachment 19 Structural Support for VFDs.pdf PDF
Attachment 21 BEP-E1R613 Model Chiller Plant Electrical.pdf PDF
Attachment 31 Pictures.pdf PDF
Attachment 17 M04-Cooling Tower piping plan-BEPVFD M-4.pdf PDF
Attachment 25 ax-dcm-06 Main Roof Top.pdf PDF
Attachment 4 - Pricing Table Revision 01 Amendment 0002.pdf PDF
Attachment 27 ax-dca-09 Annex Roof Top.pdf PDF
Attachment 22 BEP-E2R0613 Layout1 Chiller Plant Electrical 2.pdf PDF
Attachment 32 Pictures.pdf PDF
Attachment 24 Cooling Tower Information BEP Chilled Water Plant.pdf PDF
Attachment 12 75D-04.0-01 Emergency Action and Fire Prevention Plan.pdf PDF
2031ZA26R00027 Revision 01 11052026.pdf PDF
Attachment 30 Pictures.pdf PDF
Attachment 26 M-DCA-09-1001023-HV.pdf PDF
Attachment 15 M02-schematic-BEPVFD Model Chiller Planty Flow Schematic mechanical 2.pdf PDF
Attachment 23 BEP-M1R613 w chiller Layout1.pdf PDF
2031ZA26R00027 0002.pdf PDF
2031ZA26R00027 0001.pdf PDF
Attachment 4 - Pricing Table.pdf PDF
Attachment 5 - Quality Assurance Surveillance Plan (QASP).pdf PDF
Attachment 3 - Statement of Work - Cooling Towers.pdf PDF
2031ZA26R00027.pdf PDF
Attachment 2 - Davis-Bacon Wage Determination DC20260001 Modification 06.pdf PDF
Attachment 1 - Past Performance Questionnaire.pdf PDF
Attachment 6 - Initial Staffing Plan.pdf PDF
Attachment 7 - Monthly Workforce Report.pdf PDF
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

File details come from the government source that posted it. Updated .