Attachment_3-_architectural_revisions.pdf

PDF 2 MB Posted

Attached to
Building 14 and Building 53A Renovation Federal contract opportunity
Solicitation number
15-223-SOL-00107
Issued by
Department of Health and Human Services Food and Drug Administration

About this file

Attachment 3- architectural revisions

View the file

Other files for this federal contract opportunity

Other files attached to Building 14 and Building 53A Renovation, newest first.
File Type Posted
amendment_7.pdf PDF
Attachment_1_23_08_00_-_Commissioning_Of_HVAC_Systems_bldg_14.pdf PDF
Attachment_2_23_08_00_-_Commissioning_Of_HVAC_Systems_53A.pdf PDF
Amendment_6.pdf PDF
amendment_5.pdf PDF
Attachment_1_site_visit_list.pdf PDF
Attachment_2-_Revised_drawing_MH101_in_attachment_J-3_of_solicitation.pdf PDF
amendment_4.pdf PDF
Attachment_J-10.pdf PDF
Amendment_3.pdf PDF
Amendment_2.pdf PDF
Attachment_1.pdf PDF
Amendment_1.pdf PDF
Attachment_J-8_bldg_53A_chiller_2_replacement.pdf PDF
Attachment_J-3_(1_of_3).pdf PDF
Attachment_J-3_(2_of_3).pdf PDF
Attachment_J-1_(3_of_4).pdf PDF
Attachment_J-1_(4_of_4).pdf PDF
Attachment_J-3_(3_of_3).pdf PDF
Attachment_J-1_(1_of_4).pdf PDF
Attachment_J-12_SAMPLE_CLIENT__LETTER.doc DOC document
Attachment_J-5_(_1_of_3)_Building_53A_Replace_Air_Handlers_ _2nd_Floor_Offices.pdf PDF
Attachment_J-11_FDA_Form_3398.pdf PDF
Attachment_J-4_Bldg_53A__Renovate_Animal_Rms__Labs__Specs.pdf PDF
15-223-SOL-00107.pdf PDF
Attachment_J-6_Bldg_53A__Air_Handlers_ _2nd_Floor_Offices__TME_Specs.pdf PDF
Attachment_J-6_Bldg_53A__Air_Handlers_ _2nd_Floor_Offices__Stuck_Specs.pdf PDF
Attachment_J-2_Bldg_14_-_Renovate_Labs_-_Specs.pdf PDF
Attachment_J-9_Wage_Decision.pdf PDF
Attachment_J-1_(2_of_4).pdf PDF
Attachment_J-10_FDA_Form_3391.pdf PDF
Attachment_J-5_(_2_of_3)_Building_53A_Replace_Air_Handlers_ _2nd_Floor_Offices.pdf PDF
Attachment_J-5_(_3_of_3)_Building_53A_Replace_Air_Handlers_ _2nd_Floor_Offices.pdf PDF
Attachment_J-7_Building_53_Chiller_Replacement.pdf PDF
Show all 34

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OS OS

OS OS

OS OS

OS OS

OS

OS

OS

OS

OSOS

OS OS

OS

OS OS

OSOS

OS OS

OS OS

OS

OS OS

OS

OS

OS

OS

OSOS

OS

OS

OS

OS

OS

OS

OS

OS

OS OS OS

OS

OS OS

OS OS

OS OS OS OS OS OS

OS

OS

OS

OS

OS

OS

OSOS OS OS

OS

OS

A

B

C

D

E

F

.7 1 1.4 2 2.5 3 3.5 4 4.5 5 5.5 6

A-301

A-301

A-302

1A

2A

A.F.F.

2' x 2' ACT System

9' - 0"

A.F.F.

2' x 2' ACT System

8' - 0"A.F.F.

2' x 2' ACT System

8' - 0"

A.F.F.

2' x 2' ACT System

8' - 0" A.F.F.

2' x 2' ACT System

8' - 0"

A.F.F.

2' x 2' ACT System 10' - 0"

A.F.F.

2' x 2' ACT System

9' - 0"

A.F.F.

2' x 2' ACT System 10' - 0"

VESTIBULE

CORRIDOR

1001B

ULTRA COOL

OZONE FREE LAB

CELL CULTURE LAB

GENERAL PURPOSE LAB

GC/ICP MASS SPEC LAB

HPLC LAB 3

INHALATION CHEM LAB

CHEM LAB

CORRIDOR

TMP LAB

MASS SPEC

NAN LAB

CAO LAB

MOLECULAR BIO LAB

1016A

CORRIDOR

GENERAL STORAGE

BIOCHEM LAB

CORRIDOR

MEN

GEN. STORAGE

ICE MACHINE

GPT LAB

WOMEN

SMOKE LAB

TISSUE CULTURE

CART STORAGE

TELE/DATA

CORRIDOR

COMET PRINT

GLASS WASH SUPPORT

1033 CHEMICAL STORAGE

TC/HPRT LAB

1035A

MLA LAB

FLO CYTOMETRY LAB 3

1037A

CORRIDOR

TELE/DATA

MEN

ICE MACHINE

WOMEN

GENE EXPRESN LAB 1

GENE EXPRESN LAB 2

CORRIDOR

1069A

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

1076 OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CONFERENCE

CORRIDOR

1114B

CONFERENCE

DIRECTOR'S OFFICE

1128OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

SPRINKLER

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CORRIDOR

1001A

GENETICS LAB

1016B

FLO CYTOMETRY LAB 2

1035B

FLO CYTOMETRY LAB 1

1037B

HPLC LAB 2

GLASS WASH

1033A

COMPOSITE METAL SOFFIT PANEL

COMPOSITE METAL SOFFIT PANEL

SUSPENDED

LIGHT FIXTURES,

REF. ELECTRICAL

F.2

E.9

F.3

F.4

F.6

W1

D.3

4A 4A

3A

A-105

LAY-IN ACOUSTICAL

CEILING GRID

LIGHT FIXTURE - SEE

ELECTRICAL DRAWINGS

RETURN AIR GRILLE

SUPPLY AIR GRILLE

SYMBOLS LEGEND

CEILING MOUNTED EXIT LIGHT

EMERGENCY LIGHT

FIXTURE - SEE

ELECTRICAL DRAWINGS

EMERGENCY LIGHT

FIXTURE W/BATTERY PACK -

SEE ELECTRICAL DRAWINGS

GYP. BOARD CEILING -

FINISH AS SCHEDULED

METAL PANEL CEILING -

FINISH AS SCHEDULED

REFLECTED CEILING PLAN GENERAL NOTES

1.ALL AREAS OF EXPOSED EXISTING ROOF STRUCTURE AND DECK

SHALL BE COVERED WITH PRE-FINISHED METAL PANELS,

SPANNING BETWEEN THE EXISTING JOISTS. REF.

SPECIFICATIONS

2.REFER TO FINISH SCHEDULE FOR ADDITIONAL CEILING

INFORMATION

3.REFER TO LIFE SAFETY, MECHANICAL, AND ELECTRICAL

DRAWINGS FOR ADDITIONAL INFORMATION NOT SHOWN

CROMWELL

ARCHITECTS/

ENGINEERS

#5A

R

KANSAS -ENG

IN

EE

R

C E R T

IF

IC

AT

EOF

AUTHORIZ

A T

IO

N R

E G

IS

T E

RED A R CH IT E C

T

A R K A N S A S

GREGORY B.

COCKMON

15-JUL-2015

SHEETDRAWING NOSUBMITTED

SCALE DATE DRAWN CHECK

REVISION BULLETIN 002

NO. DATE DESCRIPTION BY CHECK

JEFFERSON,ARKANSAS 72079

NATIONAL CENTER FOR TOXICOLOGICAL RESEARCH

N C T R

BUILDING 14 RENOVATION

REFLECTED CEILING PLAN - PHASE I

A-10407/15/15

1/8" = 1'-0"

1 REFLECTED CEILING PLAN - PHASE I

SCALE : 1/8" = 1'-0"

0 4 8 16

TR

UE

N

OR

TH

PL

AN

N O

RT

H

OS

OS OS

OS

OS

OS

OS

OS

OS

OS

OS

OSOS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS OS OS OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS OS OS

OS

A

B

C

D

E

F

6 6.5 7 7.5 8 8.6 9 9.3 10.1

A-301

A-303

1A

2A

A-303

A.F.F.

2' x 2' ACT System

9' - 0"

A.F.F.

2' x 2' ACT System

9' - 0"

A.F.F.

2' x 2' ACT System 10' - 0"

A.F.F.

2' x 2' ACT System

9' - 0"

A.F.F.

2' x 2' ACT System 10' - 0"

A.F.F.

2' x 2' ACT System

9' - 0"

A.F.F.

2' x 2' ACT System 14' - 0"

A.F.F.

2' x 2' ACT System 14' - 0"

CORRIDOR

OMIPRINT MS LAB

MOLECULAR LAB 1

CELL LAB

1048B

AMES LAB

TC LAB

ACBPCR LAB

CORRIDOR

TC LAB

PCR LAB

RAPID B-FLOW

CYTOMETRY

GENERAL STORAGE

MASS SPEC LAB

LOW CONCENTRATION

PREP LAB

HIGH CONCENTRATION

PREP LAB

CORRIDOR

ULTRA COOL

CHEMISTRY LAB

HUMAN SAMPLE PREP

PENCE MASS SPEC LAB

CELL CULTURE LAB

SAMPLE PREP

PROTEOMICS MASS SPEC

LAB

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

LOBBY S.E.

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

SPRINKLER

OFFICE

OFFICE

1124VENDING

ENTRY

VENDING

ENTRY

LOBBY N.E.

CORRIDOR

STAIR

F.2

E.9

F.3

F.4

F.6

W1

D.3

COMPOSITE METAL

SOFFIT PANEL

COMPOSITE METAL

SOFFIT PANEL

.5

:1

.5

:1

.5

:1

9' - 0"

8' - 0"

8' - 0"

9' - 0"

.5

:1

.5

:1

.5

:1

8' - 0"

4A

3A

A-301

A-301

LAY-IN ACOUSTICAL

CEILING GRID

LIGHT FIXTURE - SEE

ELECTRICAL DRAWINGS

RETURN AIR GRILLE

SUPPLY AIR GRILLE

SYMBOLS LEGEND

CEILING MOUNTED EXIT LIGHT

EMERGENCY LIGHT

FIXTURE - SEE

ELECTRICAL DRAWINGS

EMERGENCY LIGHT

FIXTURE W/BATTERY PACK -

SEE ELECTRICAL DRAWINGS

GYP. BOARD CEILING -

FINISH AS SCHEDULED

METAL PANEL CEILING -

FINISH AS SCHEDULED

REFLECTED CEILING PLAN GENERAL NOTES

1.ALL AREAS OF EXPOSED EXISTING ROOF STRUCTURE AND DECK

SHALL BE COVERED WITH PRE-FINISHED METAL PANELS,

SPANNING BETWEEN THE EXISTING JOISTS. REF.

SPECIFICATIONS

2.REFER TO FINISH SCHEDULE FOR ADDITIONAL CEILING

INFORMATION

3.REFER TO LIFE SAFETY, MECHANICAL, AND ELECTRICAL

DRAWINGS FOR ADDITIONAL INFORMATION NOT SHOWN

Second Floor

11' - 2" e-lp02

11' - 2" f-fp02

10' - 10 1/2" m-fp02

11' - 2"

C DC D

Mech. Platform

11' - 2"

EXISTING STEEL JOISTS

AND BRACING

SUSPENDED LIGHT FIXTURES

MECHANICAL DUCTWORK

PRE-FINISHED METAL PANEL TIGHT TO

UNDERSIDE OF EXISTING DECK, SPAN

BETWEEN JOISTS, PAINT

METAL STUD WALL, REF.

PARTITION TYPES

METAL STUD WALL, REF.

PARTITION TYPES

A-105

Second Floor

11' - 2" e-lp02

11' - 2" f-fp02

10' - 10 1/2" m-fp02

11' - 2"

Mech. Platform

11' - 2"

EXISTING LIGHTWEIGHT

CONCRETE DECK

EXISTING FIBERGLASS

PANELS IN BULB-TEE

GRID SYSTEM

PRE-FINISHED METAL

PANEL CEILING, HELD

TIGHT TO BOTTOM OF

FIBERGLASS PANELS, SPAN

BETWEEN JOISTS

BACKER ROD &

SEALANT, TYP.

PRE-FINISHED METAL

END TRIM, MIN. 4"

4"

CROMWELL

ARCHITECTS/

ENGINEERS

#5A

R

KANSAS -ENG

IN

EE

R

C E R T

IF

IC

AT

EOF

AUTHORIZ

A T

IO

N R

E G

IS

T E

RED A R CH IT E C

T

A R K A N S A S

GREGORY B.

COCKMON

15-JUL-2015

SHEETDRAWING NOSUBMITTED

SCALE DATE DRAWN CHECK

REVISION BULLETIN 002

NO. DATE DESCRIPTION BY CHECK

JEFFERSON,ARKANSAS 72079

NATIONAL CENTER FOR TOXICOLOGICAL RESEARCH

N C T R

BUILDING 14 RENOVATION

REFLECTED CEILING PLAN - PHASE II

A-10507/15/15

1/8" = 1'-0"

1 REFLECTED CEILING PLAN - PHASE II

TR

UE

N

OR

TH

PL

AN

N O

RT

H

SCALE : 1/8" = 1'-0"

0 4 8 16

1/2" = 1'-0"

2 TYPICAL LAB CEILING

3" = 1'-0"

3 ENLARGED DETAIL AT LAB CEILING

FLOORS

SV-1

EPB-1 DESCO, TROWEL APPLIED EPOXY, GRANITE SERIES #GS-201, 6" HIGH

PTB-1 STONEPEAK SIMPLY MODERN COLLECTION, COLOR: SIMPLY COFFEE

COVE BASE #612C162, 6" X 12"

P-1 SHERWIN WILLIAMS- #SW7009 PEARLY WHITE (NEUTRAL) EGGSHELL

SHERWIN WILLIAMS- #SW7032 WARM STONE (TYPICAL HOLLOW METAL

PAINT) SEMI-GLOSS

ACT-1 ARMSTRONG, ULTIMA HIGH CAC LAY-IN #1951, BEVELED TEGULAR W/ 15/16" GRID, 24" X 24"

RB-1 JOHNSONITE, 4" HIGH RESILIENT BASE, COLOR: FAWN #80CB

P-2

P-3

P-6

CPT-1

EP-1 DESCO, EPOXY FLOORING,GRANITE SERIES #GS-201, COLOR : TBD

SC STAIN: AMERIPOLISH SURELOCK DYE, COLOR: CHOCOLATE BROWN

POLISH: RETROPLATE CONCRETE POLISHING SYSTEM

PT-1 STONEPEAK SIMPLY MODERN COLLECTION, COLOR: SIMPLY

COFFEE #USG1224162, 12" X 24", 30/70 OFFSET INSTALLATION

SVB-1 INTEGRAL COVE BASE TO MATCH SV-1, 6" HIGH

FINISHES LEGEND

BASE

WALLS

CEILINGS

MISCELLANEOUS

MILLWORK

MANNINGTON COMMERICAL FLOORING, BIOSPEC MD, #15240 COOL BEIGE (LC)

CARPET, MODULAR: MANNINGTON COMMERICAL FLOORING, TAKING SHAPE

NOW, COLOR: CHAI LATTE #83098, 24" X 24",RANDOM INSTALLATION METHOD

SHERWIN WILLIAMS- #SW7030 ANEW GRAY (NEUTRAL) EGGSHELL

PT-2 STONEPEAK SIMPLY MODERN COLLECTION, COLOR: SIMPLY TAN

#USG1224164, 12" X 24", 30/70 OFFSET VERTICAL PATTERN

TP-1

TOILET PARTITIONS: SCRANTON PRODUCTS, HINY HIDERS,(HDPE),

COLOR: PARCHMENT

P-5

SHERWIN WILLIAMS #SW7006 EXTRA WHITE (EXPOSED CEILING) DRY FOG

P-4

SHERWIN WILLIAMS EPOXY #SW7009 PEARLY WHITE (LABS AND

RESTROOMS)

SHERWIN WILLIAMS #SW7006 EXTRA WHITE (CEILINGS) THOROCOAT

EP-1 DESCO, EPOXY WALLS,GRANITE SERIES #GS-201, 4' ABOVE BASE

CG-1

WP-1

WOS CONSTRUCTION SPECIALTIES, PEDITREAD SA SYSTEM

TAPERED ANGLE FRAME,COLOR: COLOR ANODIZED

SS-1 CORIAN SOLID SURFACE, COLOR: CONCRETE

INPRO CORP, COLOR: 0119 PEPPERDUST, 4' X 8' SHEETS

INPRO CORP, COLOR: 0119 PEPPERDUST. MODEL G2-150. 3"

1. TOILET PARTITIONS TO BE FLOOR MOUNTED OVERHEAD BRACED WITH TP-1.

2. HOLLOW METAL DOORS AND TRIM TO BE PAINTED AS P-3.

3. GROUT COLORS TO BE AS FOLLOWS: PT-1 TO MATCH EPOXY CUSTOM

BUILDING PRODUCTS "NEW TAUPE" #185 ;

PT-2 TO MATCH NON-SANDED CUSTOM BUILDING PRODUCTS "BONE" #382 .

4. ROLLER SHADES ON ALL EXTERIOR WINDOWS TO BE 3% OPENNESS, MANUAL,

COLOR SELECTED FROM MANUFACTURERS STANDARD OFFERING.

5. SHEET VINYL WELDING RODS TO BE MANNINGTON COMMERCIAL FLOORING

COLOR TO BE #415140 "CAMOUFLAGE" ROD. SEAL WITH QUANTUM GUARD HP.

6. WINDOW SILLS TO RECEIVE SS-1.

7. EPOXY FLOORING AND WALL MATERIAL TO BE TROWEL GRADE "TG".

8. ENTRANCE AREAS AT CORRIDORS 1114A, 1114B,1069A, 1069B, AND VESTIBULE

1000 TO RECEIVE 10'-0" LONG X 6'-0 WIDE ROLL OUT RUBBER MATS

9. CORRIDORS 1001A/B, 1011, 1017, 1038, 1031, 1020, 1046, 1052, AND 1060 TO

RECEIVE WALL PROTECTION STARTING AT THE TOP OF THE BASE AND ENDING AT

4' 4" A.F.F. 4' X 8' SHEETS.

10. CORRIDORS 1001A/B, 1011, 1017, 1038, 1031, 1020, 1046, 1052, 1060, 1114A/B,

1069A/B, AND 1101 TO RECEIVE CORNER GUARDS STARTING AT THE BASE AND

EXTENDING TO 8' 4" A.F.F. GUARDS ARE 8' IN LENGTH AND 3" SURFACE MOUNTED.

11. GLASS WASH 1033: EPOXY TO EXTEND UP WALL TO 4'-0" A.F.F. PAINT ABOVE AS

SCHEDULED.

12. COLUMNS IN CORRIDORS 1069A, 1114B, AND 1102 TO BE PAINTED TO MATCH P-

1 COLOR. PAINT SYSTEM AS SPECIFIED FOR MATERIAL TYPE.

13. WALK-OFF SYSTEM (WOS) IN LOBBIES 1101 AND 1113 TO BE WOS.

GENERAL NOTES:

MATERIAL LEGEND

--- "NO" OR "NONE"

ACT ACOUSTICAL CEILING TILE

CG CORNER GUARD

SC STAINED AND SEALED CONCRETE

CPT CARPET

EPB INTEGRAL EPOXY COVE BASE

EP EPOXY- FLOORING

EPT EPOXY PAINT

EXP EXPOSED STRUCTURE

GWB GYPSUM WALL BOARD

MRGWB MOISTURE RESISTANT GYPSUM WALL BOARD

P PAINT

PT PORCELAIN TILE

PTB PORCELAIN TILE BASE

RB RESILIENT BASE

SVB INTEGRAL SHEET VINYL BASE

SV SHEET VINYL

TP TOILET PARTITIONS

WOM WALK-OFF MAT

WOS WALK-OFF SYSTEM

WP WALL PROTECTION

SS SOLID SURFACE

EXST EXISTING

CMU CONCRETE MASONRY UNIT

MTL METAL PANEL CEILING

CROMWELL

ARCHITECTS/

ENGINEERS

#5A

R

KANSAS -ENG

IN

EE

R

C E R T

IF

IC

AT

EOF

AUTHORIZ

A T

IO

N R

E G

IS

T E

RED A R CH IT E C

T

A R K A N S A S

GREGORY B.

COCKMON

15-JUL-2015

SHEETDRAWING NOSUBMITTED

SCALE DATE DRAWN CHECK

REVISION BULLETIN 002

NO. DATE DESCRIPTION BY CHECK

JEFFERSON,ARKANSAS 72079

NATIONAL CENTER FOR TOXICOLOGICAL RESEARCH

N C T R

BUILDING 14 RENOVATION

ROOM FINISH SCHEDULE - PHASE I

A-60107/15/15

ROOM FINISH SCHEDULE - Phase 1

ROOM

FLOOR BASE

NORTH WALL SOUTH WALL EAST WALL WEST WALL CEILING

NotesNUMBER NAME MATERIAL COLOR MATERIAL COLOR MATERIAL COLOR MATERIAL COLOR MATERIAL COLOR Ceiling Height

1000 VESTIBULE EP-1, WOM EPB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 MTL, EXP P-4, P-6 TIGHT TO DECK

1001A CORRIDOR EP-1 EPB-1 GWB WP-1, P-5 GWB WP-1, P-5 --- --- GWB WP-1, P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1001B CORRIDOR EP-1 EPB-1 EXST P-5 EXST P-5 GWB WP-1, P-5 GWB WP-1, P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1002 ULTRA COOL EP-1 EPB-1 EXST P-5 CMU P-5 CMU P-5 EXST P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1003 OZONE FREE LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1004 CELL CULTURE LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1005 GENERAL PURPOSE LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1006 GC/ICP MASS SPEC LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1007 HPLC LAB 3 SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1008 HPLC LAB 2 SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1009 INHALATION CHEM LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1010 CHEM LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1011 CORRIDOR EP-1 EPB-1 EXST/GWB P-5 GWB P-5 GWB WP-1, P-5 GWB WP-1, P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1012 TMP LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1013 MASS SPEC SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1014 NAN LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1015 CAO LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1016A MOLECULAR BIO LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 --- --- MTL, EXP P-4, P-6 TIGHT TO DECK

1016B GENETICS LAB SV-1 SVB-1 GWB P-5 GWB P-5 --- --- GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1017 CORRIDOR EP-1 EPB-1 EXST/GWB P-5 GWB P-5 GWB WP-1, P-5 GWB WP-1, P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1018 GENERAL STORAGE SV-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 MTL, EXP P-4, P-6 TIGHT TO DECK

1019 BIOCHEM LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1020 CORRIDOR EP-1 EPB-1 GWB WP-1, P-5 GWB WP-1, P-5 --- --- --- --- MTL, EXP P-4, P-6 TIGHT TO DECK

1021 MEN PT-1 PTB-1 GWB P-5 GWB P-5 PT PT-2 PT PT-2 ACT ACT-1 8'-0"

1022 GEN. STORAGE SV-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 MTL, EXP P-4, P-6 TIGHT TO DECK

1023 ICE MACHINE SV-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 MTL, EXP P-4, P-6 TIGHT TO DECK

1024 GPT LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1025 WOMEN PT-1 PTB-1 GWB P-5 GWB P-5 PT PT-2 PT PT-2 ACT ACT-1 8'-0"

1026 SMOKE LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1027 TISSUE CULTURE SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1028 CART STORAGE SV-1 SVB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 MTL, EXP P-4, P-6 TIGHT TO DECK

1030 TELE/DATA SV-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 MTL, EXP P-4, P-6 TIGHT TO DECK

1031 CORRIDOR EP-1 EPB-1 GWB WP-1, P-5 GWB WP-1, P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1032 COMET PRINT SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1033 GLASS WASH SUPPORT EP-1 EPB-1 MRGWB EP-1, P-5 MRGWB EP-1, P-5 MRGWB EP-1, P-5 MRGWB EP-1, P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1033A GLASS WASH EP-1 EPB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1034 CHEMICAL STORAGE SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1035A TC/HPRT LAB SV-1 SVB-1 GWB P-5 --- --- GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1035B FLO CYTOMETRY LAB 2 SV-1 SVB-1 --- --- GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1036 MLA LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1037A FLO CYTOMETRY LAB 3 SV-1 SVB-1 GWB P-5 --- --- GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1037B FLO CYTOMETRY LAB 1 SV-1 SVB-1 --- --- GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1038 CORRIDOR EP-1 EPB-1 GWB/ EXST WP-1, P-5 GWB WP-1, P-5 --- --- --- --- MTL, EXP P-4, P-6 TIGHT TO DECK

1039 TELE/DATA SV-1 SVB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 MTL, EXP P-4, P-6 TIGHT TO DECK

1040 MEN PT-1 PTB-1 GWB P-5 GWB P-5 PT PT-2 PT PT-2 ACT ACT-1 8'-0"

1041 ICE MACHINE SV-1 SVB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 MTL, EXP P-4, P-6 TIGHT TO DECK

1042 WOMEN PT-1 PTB-1 GWB P-5 GWB P-5 PT PT-2 PT PT-2 ACT ACT-1 8'-0"

1043 GENE EXPRESN LAB 1 SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1044 GENE EXPRESN LAB 2 SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1069A CORRIDOR SC, WOM RB-1 GWB P-1 GWB P-2 --- --- GWB P-1 ACT ACT-1 10'-0"

1070 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1071 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1072 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1073 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1074 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1075 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1076 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1077 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1078 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1079 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1080 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1081 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1082 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1083 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1084 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1085 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1086 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1087 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1088 CONFERENCE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1114B CORRIDOR SC, WOM RB-1 GWB P-2 GWB/ EXST P-1 --- --- GWB P-1 ACT ACT-1 10'-0"

1127 CONFERENCE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1128 DIRECTOR'S OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1129 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1130 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1131 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1132 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1133 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1134 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1135 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1136 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1137 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1138 SPRINKLER SC RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1139 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1140 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1141 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1142 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1143 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1144 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1145 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1 1

FLOORS

SV-1

EPB-1 DESCO, TROWEL APPLIED EPOXY, GRANITE SERIES #GS-201, 6" HIGH

PTB-1 STONEPEAK SIMPLY MODERN COLLECTION, COLOR: SIMPLY COFFEE

COVE BASE #612C162, 6" X 12"

P-1 SHERWIN WILLIAMS- #SW7009 PEARLY WHITE (NEUTRAL) EGGSHELL

SHERWIN WILLIAMS- #SW7032 WARM STONE (TYPICAL HOLLOW METAL

PAINT) SEMI-GLOSS

ACT-1 ARMSTRONG, ULTIMA HIGH CAC LAY-IN #1951, BEVELED TEGULAR W/ 15/16" GRID, 24" X 24"

RB-1 JOHNSONITE, 4" HIGH RESILIENT BASE, COLOR: FAWN #80CB

P-2

P-3

P-6

CPT-1

EP-1 DESCO, EPOXY FLOORING,GRANITE SERIES #GS-201, COLOR : TBD

SC STAIN: AMERIPOLISH SURELOCK DYE, COLOR: CHOCOLATE BROWN

POLISH: RETROPLATE CONCRETE POLISHING SYSTEM

PT-1 STONEPEAK SIMPLY MODERN COLLECTION, COLOR: SIMPLY

COFFEE #USG1224162, 12" X 24", 30/70 OFFSET INSTALLATION

SVB-1 INTEGRAL COVE BASE TO MATCH SV-1, 6" HIGH

FINISHES LEGEND

BASE

WALLS

CEILINGS

MISCELLANEOUS

MILLWORK

MANNINGTON COMMERICAL FLOORING, BIOSPEC MD, #15240 COOL BEIGE (LC)

CARPET, MODULAR: MANNINGTON COMMERICAL FLOORING, TAKING SHAPE

NOW, COLOR: CHAI LATTE #83098, 24" X 24",RANDOM INSTALLATION METHOD

SHERWIN WILLIAMS- #SW7030 ANEW GRAY (NEUTRAL) EGGSHELL

PT-2 STONEPEAK SIMPLY MODERN COLLECTION, COLOR: SIMPLY TAN

#USG1224164, 12" X 24", 30/70 OFFSET VERTICAL PATTERN

TP-1

TOILET PARTITIONS: SCRANTON PRODUCTS, HINY HIDERS,(HDPE),

COLOR: PARCHMENT

P-5

SHERWIN WILLIAMS #SW7006 EXTRA WHITE (EXPOSED CEILING) DRY FOG

P-4

SHERWIN WILLIAMS EPOXY #SW7009 PEARLY WHITE (LABS AND

RESTROOMS)

SHERWIN WILLIAMS #SW7006 EXTRA WHITE (CEILINGS) THOROCOAT

EP-1 DESCO, EPOXY WALLS,GRANITE SERIES #GS-201, 4' ABOVE BASE

CG-1

WP-1

WOS CONSTRUCTION SPECIALTIES, PEDITREAD SA SYSTEM

TAPERED ANGLE FRAME,COLOR: COLOR ANODIZED

SS-1 CORIAN SOLID SURFACE, COLOR: CONCRETE

INPRO CORP, COLOR: 0119 PEPPERDUST, 4' X 8' SHEETS

INPRO CORP, COLOR: 0119 PEPPERDUST. MODEL G2-150. 3"

1. TOILET PARTITIONS TO BE FLOOR MOUNTED OVERHEAD BRACED WITH TP-1.

2. HOLLOW METAL DOORS AND TRIM TO BE PAINTED AS P-3.

3. GROUT COLORS TO BE AS FOLLOWS: PT-1 TO MATCH EPOXY CUSTOM

BUILDING PRODUCTS "NEW TAUPE" #185 ;

PT-2 TO MATCH NON-SANDED CUSTOM BUILDING PRODUCTS "BONE" #382 .

4. ROLLER SHADES ON ALL EXTERIOR WINDOWS TO BE 3% OPENNESS, MANUAL,

COLOR SELECTED FROM MANUFACTURERS STANDARD OFFERING.

5. SHEET VINYL WELDING RODS TO BE MANNINGTON COMMERCIAL FLOORING

COLOR TO BE #415140 "CAMOUFLAGE" ROD. SEAL WITH QUANTUM GUARD HP.

6. WINDOW SILLS TO RECEIVE SS-1.

7. EPOXY FLOORING AND WALL MATERIAL TO BE TROWEL GRADE "TG".

8. ENTRANCE AREAS AT CORRIDORS 1114A, 1114B,1069A, 1069B, AND VESTIBULE

1000 TO RECEIVE 10'-0" LONG X 6'-0 WIDE ROLL OUT RUBBER MATS

9. CORRIDORS 1001A/B, 1011, 1017, 1038, 1031, 1020, 1046, 1052, AND 1060 TO

RECEIVE WALL PROTECTION STARTING AT THE TOP OF THE BASE AND ENDING AT

4' 4" A.F.F. 4' X 8' SHEETS.

10. CORRIDORS 1001A/B, 1011, 1017, 1038, 1031, 1020, 1046, 1052, 1060, 1114A/B,

1069A/B, AND 1101 TO RECEIVE CORNER GUARDS STARTING AT THE BASE AND

EXTENDING TO 8' 4" A.F.F. GUARDS ARE 8' IN LENGTH AND 3" SURFACE MOUNTED.

11. GLASS WASH 1033: EPOXY TO EXTEND UP WALL TO 4'-0" A.F.F. PAINT ABOVE AS

SCHEDULED.

12. COLUMNS IN CORRIDORS 1069A, 1114B, AND 1102 TO BE PAINTED TO MATCH P-

1 COLOR. PAINT SYSTEM AS SPECIFIED FOR MATERIAL TYPE.

13. WALK-OFF SYSTEM (WOS) IN LOBBIES 1101 AND 1113 TO BE WOS.

GENERAL NOTES:

MATERIAL LEGEND

--- "NO" OR "NONE"

ACT ACOUSTICAL CEILING TILE

CG CORNER GUARD

SC STAINED AND SEALED CONCRETE

CPT CARPET

EPB INTEGRAL EPOXY COVE BASE

EP EPOXY- FLOORING

EPT EPOXY PAINT

EXP EXPOSED STRUCTURE

GWB GYPSUM WALL BOARD

MRGWB MOISTURE RESISTANT GYPSUM WALL BOARD

P PAINT

PT PORCELAIN TILE

PTB PORCELAIN TILE BASE

RB RESILIENT BASE

SVB INTEGRAL SHEET VINYL BASE

SV SHEET VINYL

TP TOILET PARTITIONS

WOM WALK-OFF MAT

WOS WALK-OFF SYSTEM

WP WALL PROTECTION

SS SOLID SURFACE

EXST EXISTING

CMU CONCRETE MASONRY UNIT

MTL METAL PANEL CEILING

CROMWELL

ARCHITECTS/

ENGINEERS

#5A

R

KANSAS -ENG

IN

EE

R

C E R T

IF

IC

AT

EOF

AUTHORIZ

A T

IO

N R

E G

IS

T E

RED A R CH IT E C

T

A R K A N S A S

GREGORY B.

COCKMON

15-JUL-2015

SHEETDRAWING NOSUBMITTED

SCALE DATE DRAWN CHECK

REVISION BULLETIN 002

NO. DATE DESCRIPTION BY CHECK

JEFFERSON,ARKANSAS 72079

NATIONAL CENTER FOR TOXICOLOGICAL RESEARCH

N C T R

BUILDING 14 RENOVATION

ROOM FINISH SCHEDULE - PHASE II

A-60207/15/15

ROOM FINISH SCHEDULE - Phase 2

ROOM

FLOOR BASE

NORTH WALL SOUTH WALL EAST WALL WEST WALL CEILING

NotesNUMBER NAME MATERIAL COLOR MATERIAL COLOR MATERIAL COLOR MATERIAL COLOR MATERIAL COLOR Ceiling Height

1046 CORRIDOR EP-1 EPB-1 EXST P-5 EXST P-5 GWB WP-1, P-5 EXST WP-1, P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1047 OMIPRINT MS LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1048 MOLECULAR LAB 1 SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1048B CELL LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1049 AMES LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1050 TC LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1051 ACBPCR LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1052 CORRIDOR SV-1 SVB-1 GWB/EXST P-5 EXST P-5 GWB WP-1, P-5 GWB WP-1, P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1053 TC LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1054 PCR LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1055 RAPID B-FLOW CYTOMETRY SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1056 GENERAL STORAGE SV-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 MTL, EXP P-4, P-6 TIGHT TO DECK

1057 MASS SPEC LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1058 LOW CONCENTRATION PREP LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1059 HIGH CONCENTRATION PREP LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1060 CORRIDOR EP-1 EPB-1 EXST P-5 EXST P-5 GWB WP-1, P-5 GWB WP-1, P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1061 ULTRA COOL EP-1 EPB-1 CMU P-5 CMU P-5 CMU P-5 CMU P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1062 CHEMISTRY LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1063 HUMAN SAMPLE PREP SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1065 PENCE MASS SPEC LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1066 CELL CULTURE LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1067 SAMPLE PREP SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1068 PROTEOMICS MASS SPEC LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK

1089 ENTRY SC, WOM RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1090 VENDING SC RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1091 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1092 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1093 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1094 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1095 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1096 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1097 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1098 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1099 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1100 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1101 LOBBY S.E. SC, WOS RB-1 GWB/EXST P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 14'-0"

1102 CORRIDOR SC RB-1 --- --- --- --- GWB P-2 GWB P-1 ACT ACT-1 10'-0"

1103 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1104 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1105 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1106 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1107 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1108 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1109 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1110 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1111 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1112 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1113 LOBBY N.E. SC RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 14'-0"

1114 STAIR NO WORK

1115 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1116 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1117 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1118 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1119 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1120 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1121 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1122 SPRINKLER SC RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 EXP P-4, P-6 ---

1123 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1124 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"

1125 VENDING SC RB-1 GWB P-1 --- --- GWB P-1 --- --- ACT ACT-1 9'-0"

1126 ENTRY SC, WOM RB-1 GWB P-1 --- --- GWB --- EXST P-1 ACT ACT-1 9'-0"

NCTR-Building 14 Renovation 2015-056 Jefferson, Arkansas July 2015

METAL PANELS

PR002 07 42 13 - 1

SECTION 07 42 13

METAL PANELS

PART 1 GENERAL

1.01 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

1.02 RELATED REQUIREMENTS

A. Division 01 for related LEED general requirements.

B. Division 07 Section "Sheet Metal Flashing and Trim" for sheet metal copings, flashings, reglets and roof drainage items.

C. Division 07 Section "Joint Sealants" for field-applied joint sealants.

1.03 REFERENCES

A. American Architectural Manufacturer's Association (AAMA):

1. AAMA 501.1 - Test Method for Water Penetration of Windows, Curtain Walls and Doors Using Dynamic Pressure.

2. AAMA 620 - Voluntary Specification for High Performance Organic Coatings on Coil Coated Architectural Aluminum Substrates.

3. AAMA 621 - Voluntary Specification for High Performance Organic Coatings on Coil Coated Architectural Hot Dipped Galvanized (HDG) and Zinc-Aluminum Coated Steel Substrates.

B. American Society of Civil Engineers (ASCE):

1. ASCE 7 - Minimum Design Loads for Buildings and Other Structures.

C. ASTM International (ASTM):

1. ASTM A 653/A 653M - Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron

Alloy-Coated (Galvannealed) by the Hot-Dip Process.

2. ASTM A 755/A 755M - Specification for Steel Sheet, Metallic Coated by the Hot-Dip

Process and Prepainted by the Coil-Coating Process for Exterior Exposed Building Products.

3. ASTM B 209 - Specification for Aluminum and Aluminum Alloy Sheet and Plate.

4. ASTM C 754 - Specification for Installation of Steel Framing Members to Receive Screw

Attached Gypsum Panel Products.

5. ASTM C 920 - Specification for Elastomeric Joint Sealants.

6. ASTM C 1007 - Standard Specification for Installation of Load Bearing (Transverse and

Axial) Steel Studs and Related Accessories.

7. ASTM E 72 - Standard Test Methods of Conducting Strength Tests of Panels for Building

Construction.

8. ASTM E 283 - Test Method for Determining the Rate of Air Leakage Through Exterior

Windows, Curtain Walls, and Doors under Specified Pressure Differences across the Specimen.

9. ASTM E 331 - Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference.

D. Sheet Metal and Air Conditioning Contractors National Association, Inc. (SMACNA):

1. Architectural Sheet Metal Manual.

1.04 PERFORMANCE REQUIREMENTS

A. General: Provide metal wall panel assemblies meeting performance requirements as determined by application of specified tests by a qualified testing agency on manufacturer's standard assemblies.

B. Air Infiltration: Maximum 0.06 cfm/sq. ft. (0.3 L/s per sq. m) per ASTM E 283 at a static-air-pressure difference of 1.57 lbf/sq. ft. (75 Pa), using minimum 10-by-10 foot (3050-by-3050 mm) test panel that includes side joints.

METAL PANELS

PR002 07 42 13 - 2

C. Thermal Movements: Allow for thermal movements from variations in both ambient and internal temperatures. Accommodate movement of support structure caused by thermal expansion and contraction.

1.05 QUALITY ASSURANCE

A. Manufacturer/Source: Provide metal wall panel and panel accessories from a single manufacturer.

B. Manufacturer Qualifications: Approved manufacturer listed in this Section with minimum 10 years experience in manufacture of similar products in successful use in similar applications.

1. Approval of Comparable Products: Submit the following in accordance with project substitution requirements, within time allowed for substitution review:

a. Product data, including certified independent test data indicating compliance with requirements.

b. Sample submittal from similar project.

c. Project references: Minimum of 5 installations not less than 5 years old, with owner and architect contact information.

d. Sample warranty.

2. Substitutions following award of contract are not allowed except as stipulated in Division 01 General Requirements.

3. Approved manufacturers must meet separate requirements of Submittals Article.

C. Installer Qualifications: Experienced Installer with minimum of 5 years experience with successfully completed projects of a similar nature and scope.

1.06 ADMINISTRATIVE REQUIREMENTS

A. Preinstallation Meeting: Conduct preinstallation meeting at site attended by Construction Manager - Advisor, Architect Engineer, manufacturer's representative, and other trade contractors.

1. Coordinate building framing in relation to metal wall panel assembly.

2. Coordinate window, door and louver, mechanical, plumbing penatrations, other openings and penetrations of metal wall panel assembly.

1.07 ACTION SUBMITTALS

A. Product Data: Manufacturer's data sheets, for specified products.

1. Include data indicating compliance with performance requirements, including load span tables tested for side joint disengagement under negative loads per ASTM E 72.

B. Shop Drawings: Provide shop drawings prepared by manufacturer or manufacturer's authorized

Installer. Include full elevations showing openings and penetrations. Include details of each condition of installation and attachment. Provide details at a minimum scale 1-1/2-inch per foot (1:8) of all required trim and extrusions needed for a complete installation.

1. Indicate points of supporting structure that must coordinate with metal wall panel assembly installation.

C. Samples for Initial Selection: For each product specified. Provide representative color charts of manufacturer's full range of colors.

D. Samples for Verification: Provide 12-inch (300 mm) section of panel(s) showing finishes.

Provide 12-inch (300 mm) long pieces of trim pieces and other exposed components.

1.08 INFORMATIONAL SUBMITTALS

A. Product Test Reports: Indicating compliance of products with requirements, from a qualified independent testing agency.

B. Qualification Information: For Installer firm.

C. Manufacturer's warranty: Submit sample warranty.

1.09 CLOSEOUT SUBMITTALS

A. Maintenance data.

METAL PANELS

PR002 07 42 13 - 3

1.10 DELIVERY, STORAGE, AND HANDLING

A. Protect metal wall panel products during shipping, handling, and storage to prevent staining, denting, deterioration of components or other damage.

1. Deliver, unload, store, and erect metal wall panel products and accessory items without misshaping panels or exposing panels to surface damage from weather or construction operations.

1.11 WARRANTY

A. Special Manufacturer's Warranty: On manufacturer's standard form, in which manufacturer agrees to repair or replace components of metal wall panel assemblies that fail in materials and workmanship within two years from date of Substantial Completion.

B. Special Panel Finish Warranty: On manufacturer's standard form, in which manufacturer agrees to repair or replace metal wall panels that evidence deterioration of finish within the following periods from the date of substantial completion:

1. Warranty Period: 20 years.

PART 2 PRODUCTS

2.01 MANUFACTURERS

A. Basis of Design: CENTRIA, IW Series Metal Wall Panels. Provide basis of design product, or comparable product approved by Architect Engineer prior to bid.

1. CENTRIA Architectural Systems; Moon Township, PA 15108-2944. Tel: (800)759-7474.

Tel: (412)299-8000. Fax: (412)299-8317. Email: info@CENTRIA.com <mailto:info@CENTRIA.com>. Web: www.CENTRIA.com <http://www.CENTRIA.com>.

B. Acceptable Manufacturers:

1. MBCI; www.mbci.com

2.02 METAL PANEL MATERIALS

A. Smooth Prefinished Steel Face Sheet: Coil-coated, ASTM A 755/A 755M.

1. Galvanized Steel Sheet: ASTM A 653/A 653M, G90 (Class Z275), structural steel quality.

2. Face Sheet: Minimum 0.91 mm/20 gage single span nominal uncoated thickness.

2.03 CONCEALED FASTENER METAL PANELS

A. Metal Wall Panels, General: Factory-formed, concealed fastener panels with interconnecting side joints, fastened to supports with concealed fasteners, with factory-applied sealant in side laps when required to meet performance requirements.

B. Type IW-10A; Flush-joint profile with raised flat pan:

1. Basis of Design Product: CENTRIA, IW-10A.

2. Panel Coverage: 12 inches.

3. Panel Height: 1.50 inches.

2.04 METAL PANEL ACCESSORIES

A. Metal Wall Panel Accessories, General: Provide complete metal wall panel assembly incorporating trim, copings, fasciae, parapet caps, soffits, sills, inside and outside corners, and miscellaneous flashings. Provide manufacturer's factory-formed shims, flashings, gaskets, lap strips, closure strips, and caps for a complete installation. Fabricate accessories in accordance with SMACNA Manual.

B. Extruded Trim: Manufacturer's complementary aluminum extrusions for head, jamb, sill, base, flush, reveal, inside and outside corner, endwall, and expansion joint details. Finish to match metal wall panels.

1. Basis of Design: CENTRIA, Microline Extrusions.

C. Mitered Corners: Structurally-bonded horizontal interior and exterior trimless corners matching metal wall panel material, profile, and factory-applied finish, fabricated and finished by metal wall panel manufacturer.

METAL PANELS

PR002 07 42 13 - 4

1. Welded, riveted, fastened, or field- fabricated corners do not meet the requirements of this specification.

2. Basis of Design: CENTRIA, MicroSeam Corners.

D. Formed Flashing and Trim: Match material, thickness, and color of metal wall panels.

E. Sealants: Type recommended by metal wall panel manufacturer for application, meeting requirements of Division 07 Section "Joint Sealants."

F. Flashing Tape: 4-inch wide self-adhering butyl flashing tape.

G. Fasteners: Self-tapping screws and other acceptable fasteners recommended by panel manufacturer. Where exposed fasteners cannot be avoided, supply corrosion-resistant fasteners with heads matching color of metal wall panels by means factory-applied coating.

2.05 SECONDARY METAL SUBGIRT FRAMING

A. Miscellaneous Framing Components, General: Cold-formed metallic-coated steel sheet, ASTM

A 653/A 653M, G90 (Z180).

1. Hat Channels: 0.053 inch/16 ga. (1.34 mm) minimum.

2. Sill Channels: 0.053 inch/16 ga. (1.34 mm) minimum.

2.06 METAL PANEL FINISHES

A. Color:

1. Exterior Surface: Kynar finish as selected by Architect Engineer from manufacturer's standard colors.

PART 3 EXECUTION

3.01 EXAMINATION

A. Examine metal wall panel substrate with Installer present. Inspect for erection tolerances and other conditions that would adversely affect installation of metal wall panels.

B. Wall Substrate: Confirm that wall substrate is within tolerances acceptable to metal wall panel system manufacturer.

1. Maximum substrate and framing deviations from flat plane acceptable:

a. 1/4-inch in 20 feet vertically or horizontally.

b. 1/2-inch across building elevation.

c. 1/8-inch in 5 feet.

C. Framing: Inspect framing that will support metal wall panels to determine if support components are installed as indicated on approved shop drawings. Confirm presence of acceptable framing members at recommended spacing to match installation requirements of metal wall panels.

D. Openings: Verify that window, door, louver and other penetrations match layout on shop drawings.

E. Correct out-of-tolerance work and other deficient conditions prior to proceeding with metal wall panel system installation.

3.02 SECONDARY FRAMING INSTALLATION

A. Secondary Metal Subgirt Framing: Install secondary metal framing components to tolerances indicated, as shown on approved shop drawings. Install secondary metal framing and other metal panel supports per ASTM C 1007 and metal wall panel manufacturer's recommendations.

3.03 METAL PANEL INSTALLATION

A. General: Install metal wall panels in accordance with approved shop drawings and manufacturer's recommendations. Install metal wall panels in orientation, sizes, and locations indicated. Anchor metal wall panels and other components securely in place. Provide for thermal and structural movement

B. Attach panels to metal framing using recommended clips, screws, fasteners, sealants, and adhesives indicated on approved shop drawings.

METAL PANELS

PR002 07 42 13 - 5

1. Fasteners for Steel Wall Panels: Stainless-steel for exterior locations and locations exposed to moisture; carbon steel for interior use only.

2. Fasten metal wall panels to supports with fasteners and spacing recommended by manufacturer.

3. Provide weatherproof escutcheons for pipe and conduit penetrating exterior walls.

4. Dissimilar Materials: Where elements of metal wall panel system will come into contact with dissimilar materials, treat faces and edges in contact with dissimilar materials as recommended by manufacturer.

C. Joint Sealers: Install joint sealants where indicated on approved shop drawings.

3.04 ACCESSORY INSTALLATION

A. General: Install metal wall panel accessories with positive anchorage to building and provide for thermal expansion. Coordinate installation with flashings and other components.

1. Install related flashings and sheet metal trim per requirements of Division 07 Section

"Sheet Metal Flashing and Trim."

2. Install components required for a complete metal wall panel assembly, including trim, copings, corners, lap strips, flashings, sealants, fillers, closure strips, and similar items.

3. Comply with performance requirements and manufacturer's written installation instructions.

4. Provide concealed fasteners except where noted on approved shop drawings.

5. Set units true to line and level as indicated.

3.05 FIELD QUALITY CONTROL

A. Manufacturer's Field Service: Engage a service representative authorized by metal wall panel manufacturer to inspect completed installation. Submit written report.

B. Correct deficiencies noted in manufacturer's report.

3.06 CLEANING AND PROTECTION

A. Remove temporary protective films. Clean finished surfaces as recommended by metal wall panel manufacturer. Clear weep holes and drainage channels of obstructions, dirt, and sealant.

Maintain in a clean condition during construction.

B. Replace damaged panels and accessories that cannot be repaired by finish touch-up or minor repair.

END OF SECTION

2015_056-Arch_eferris@cromwell.com - Sheet - A-104 - REFLECTED CEILING PLAN - PHASE I
Sheets
A-104 - REFLECTED CEILING PLAN - PHASE I
2015_056-Arch_eferris@cromwell.com - Sheet - A-105 - REFLECTED CEILING PLAN - PHASE II
Sheets
A-104 - REFLECTED CEILING PLAN - PHASE I
A-105 - REFLECTED CEILING PLAN - PHASE II
2015_056-Arch_eferris@cromwell.com - Sheet - A-601 - ROOM FINISH SCHEDULE - PHASE I
Sheets
A-104 - REFLECTED CEILING PLAN - PHASE I
A-105 - REFLECTED CEILING PLAN - PHASE II
A-601 - ROOM FINISH SCHEDULE - PHASE I
A-602 - ROOM FINISH SCHEDULE - PHASE II
2015_056-Arch_eferris@cromwell.com - Sheet - A-602 - ROOM FINISH SCHEDULE - PHASE II
Sheets
A-104 - REFLECTED CEILING PLAN - PHASE I
A-105 - REFLECTED CEILING PLAN - PHASE II
A-601 - ROOM FINISH SCHEDULE - PHASE I
A-602 - ROOM FINISH SCHEDULE - PHASE II

07 42 13 - Metal Panels

File details come from the government source that posted it. Updated .