Attachment_3-_architectural_revisions.pdf
PDF 2 MB Posted
- Attached to
- Building 14 and Building 53A Renovation Federal contract opportunity
- Solicitation number
- 15-223-SOL-00107
About this file
Attachment 3- architectural revisions
View the file
Other files for this federal contract opportunity
Show all 34
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OS OS
OS OS
OS OS
OS OS
OS
OS
OS
OS
OSOS
OS OS
OS
OS OS
OSOS
OS OS
OS OS
OS
OS OS
OS
OS
OS
OS
OSOS
OS
OS
OS
OS
OS
OS
OS
OS
OS OS OS
OS
OS OS
OS OS
OS OS OS OS OS OS
OS
OS
OS
OS
OS
OS
OSOS OS OS
OS
OS
A
B
C
D
E
F
.7 1 1.4 2 2.5 3 3.5 4 4.5 5 5.5 6
A-301
A-301
A-302
1A
2A
A.F.F.
2' x 2' ACT System
9' - 0"
A.F.F.
2' x 2' ACT System
8' - 0"A.F.F.
2' x 2' ACT System
8' - 0"
A.F.F.
2' x 2' ACT System
8' - 0" A.F.F.
2' x 2' ACT System
8' - 0"
A.F.F.
2' x 2' ACT System 10' - 0"
A.F.F.
2' x 2' ACT System
9' - 0"
A.F.F.
2' x 2' ACT System 10' - 0"
VESTIBULE
CORRIDOR
1001B
ULTRA COOL
OZONE FREE LAB
CELL CULTURE LAB
GENERAL PURPOSE LAB
GC/ICP MASS SPEC LAB
HPLC LAB 3
INHALATION CHEM LAB
CHEM LAB
CORRIDOR
TMP LAB
MASS SPEC
NAN LAB
CAO LAB
MOLECULAR BIO LAB
1016A
CORRIDOR
GENERAL STORAGE
BIOCHEM LAB
CORRIDOR
MEN
GEN. STORAGE
ICE MACHINE
GPT LAB
WOMEN
SMOKE LAB
TISSUE CULTURE
CART STORAGE
TELE/DATA
CORRIDOR
COMET PRINT
GLASS WASH SUPPORT
1033 CHEMICAL STORAGE
TC/HPRT LAB
1035A
MLA LAB
FLO CYTOMETRY LAB 3
1037A
CORRIDOR
TELE/DATA
MEN
ICE MACHINE
WOMEN
GENE EXPRESN LAB 1
GENE EXPRESN LAB 2
CORRIDOR
1069A
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
1076 OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
CONFERENCE
CORRIDOR
1114B
CONFERENCE
DIRECTOR'S OFFICE
1128OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
SPRINKLER
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
CORRIDOR
1001A
GENETICS LAB
1016B
FLO CYTOMETRY LAB 2
1035B
FLO CYTOMETRY LAB 1
1037B
HPLC LAB 2
GLASS WASH
1033A
COMPOSITE METAL SOFFIT PANEL
COMPOSITE METAL SOFFIT PANEL
SUSPENDED
LIGHT FIXTURES,
REF. ELECTRICAL
F.2
E.9
F.3
F.4
F.6
W1
D.3
4A 4A
3A
A-105
LAY-IN ACOUSTICAL
CEILING GRID
LIGHT FIXTURE - SEE
ELECTRICAL DRAWINGS
RETURN AIR GRILLE
SUPPLY AIR GRILLE
SYMBOLS LEGEND
CEILING MOUNTED EXIT LIGHT
EMERGENCY LIGHT
FIXTURE - SEE
ELECTRICAL DRAWINGS
EMERGENCY LIGHT
FIXTURE W/BATTERY PACK -
SEE ELECTRICAL DRAWINGS
GYP. BOARD CEILING -
FINISH AS SCHEDULED
METAL PANEL CEILING -
FINISH AS SCHEDULED
REFLECTED CEILING PLAN GENERAL NOTES
1.ALL AREAS OF EXPOSED EXISTING ROOF STRUCTURE AND DECK
SHALL BE COVERED WITH PRE-FINISHED METAL PANELS,
SPANNING BETWEEN THE EXISTING JOISTS. REF.
SPECIFICATIONS
2.REFER TO FINISH SCHEDULE FOR ADDITIONAL CEILING
INFORMATION
3.REFER TO LIFE SAFETY, MECHANICAL, AND ELECTRICAL
DRAWINGS FOR ADDITIONAL INFORMATION NOT SHOWN
CROMWELL
ARCHITECTS/
ENGINEERS
#5A
R
KANSAS -ENG
IN
EE
R
C E R T
IF
IC
AT
EOF
AUTHORIZ
A T
IO
N R
E G
IS
T E
RED A R CH IT E C
T
A R K A N S A S
GREGORY B.
COCKMON
15-JUL-2015
SHEETDRAWING NOSUBMITTED
SCALE DATE DRAWN CHECK
REVISION BULLETIN 002
NO. DATE DESCRIPTION BY CHECK
JEFFERSON,ARKANSAS 72079
NATIONAL CENTER FOR TOXICOLOGICAL RESEARCH
N C T R
BUILDING 14 RENOVATION
REFLECTED CEILING PLAN - PHASE I
A-10407/15/15
1/8" = 1'-0"
1 REFLECTED CEILING PLAN - PHASE I
SCALE : 1/8" = 1'-0"
0 4 8 16
TR
UE
N
OR
TH
PL
AN
N O
RT
H
OS
OS OS
OS
OS
OS
OS
OS
OS
OS
OS
OSOS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS OS OS OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS OS OS
OS
A
B
C
D
E
F
6 6.5 7 7.5 8 8.6 9 9.3 10.1
A-301
A-303
1A
2A
A-303
A.F.F.
2' x 2' ACT System
9' - 0"
A.F.F.
2' x 2' ACT System
9' - 0"
A.F.F.
2' x 2' ACT System 10' - 0"
A.F.F.
2' x 2' ACT System
9' - 0"
A.F.F.
2' x 2' ACT System 10' - 0"
A.F.F.
2' x 2' ACT System
9' - 0"
A.F.F.
2' x 2' ACT System 14' - 0"
A.F.F.
2' x 2' ACT System 14' - 0"
CORRIDOR
OMIPRINT MS LAB
MOLECULAR LAB 1
CELL LAB
1048B
AMES LAB
TC LAB
ACBPCR LAB
CORRIDOR
TC LAB
PCR LAB
RAPID B-FLOW
CYTOMETRY
GENERAL STORAGE
MASS SPEC LAB
LOW CONCENTRATION
PREP LAB
HIGH CONCENTRATION
PREP LAB
CORRIDOR
ULTRA COOL
CHEMISTRY LAB
HUMAN SAMPLE PREP
PENCE MASS SPEC LAB
CELL CULTURE LAB
SAMPLE PREP
PROTEOMICS MASS SPEC
LAB
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
LOBBY S.E.
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
SPRINKLER
OFFICE
OFFICE
1124VENDING
ENTRY
VENDING
ENTRY
LOBBY N.E.
CORRIDOR
STAIR
F.2
E.9
F.3
F.4
F.6
W1
D.3
COMPOSITE METAL
SOFFIT PANEL
COMPOSITE METAL
SOFFIT PANEL
.5
:1
.5
:1
.5
:1
9' - 0"
8' - 0"
8' - 0"
9' - 0"
.5
:1
.5
:1
.5
:1
8' - 0"
4A
3A
A-301
A-301
LAY-IN ACOUSTICAL
CEILING GRID
LIGHT FIXTURE - SEE
ELECTRICAL DRAWINGS
RETURN AIR GRILLE
SUPPLY AIR GRILLE
SYMBOLS LEGEND
CEILING MOUNTED EXIT LIGHT
EMERGENCY LIGHT
FIXTURE - SEE
ELECTRICAL DRAWINGS
EMERGENCY LIGHT
FIXTURE W/BATTERY PACK -
SEE ELECTRICAL DRAWINGS
GYP. BOARD CEILING -
FINISH AS SCHEDULED
METAL PANEL CEILING -
FINISH AS SCHEDULED
REFLECTED CEILING PLAN GENERAL NOTES
1.ALL AREAS OF EXPOSED EXISTING ROOF STRUCTURE AND DECK
SHALL BE COVERED WITH PRE-FINISHED METAL PANELS,
SPANNING BETWEEN THE EXISTING JOISTS. REF.
SPECIFICATIONS
2.REFER TO FINISH SCHEDULE FOR ADDITIONAL CEILING
INFORMATION
3.REFER TO LIFE SAFETY, MECHANICAL, AND ELECTRICAL
DRAWINGS FOR ADDITIONAL INFORMATION NOT SHOWN
Second Floor
11' - 2" e-lp02
11' - 2" f-fp02
10' - 10 1/2" m-fp02
11' - 2"
C DC D
Mech. Platform
11' - 2"
EXISTING STEEL JOISTS
AND BRACING
SUSPENDED LIGHT FIXTURES
MECHANICAL DUCTWORK
PRE-FINISHED METAL PANEL TIGHT TO
UNDERSIDE OF EXISTING DECK, SPAN
BETWEEN JOISTS, PAINT
METAL STUD WALL, REF.
PARTITION TYPES
METAL STUD WALL, REF.
PARTITION TYPES
A-105
Second Floor
11' - 2" e-lp02
11' - 2" f-fp02
10' - 10 1/2" m-fp02
11' - 2"
Mech. Platform
11' - 2"
EXISTING LIGHTWEIGHT
CONCRETE DECK
EXISTING FIBERGLASS
PANELS IN BULB-TEE
GRID SYSTEM
PRE-FINISHED METAL
PANEL CEILING, HELD
TIGHT TO BOTTOM OF
FIBERGLASS PANELS, SPAN
BETWEEN JOISTS
BACKER ROD &
SEALANT, TYP.
PRE-FINISHED METAL
END TRIM, MIN. 4"
4"
CROMWELL
ARCHITECTS/
ENGINEERS
#5A
R
KANSAS -ENG
IN
EE
R
C E R T
IF
IC
AT
EOF
AUTHORIZ
A T
IO
N R
E G
IS
T E
RED A R CH IT E C
T
A R K A N S A S
GREGORY B.
COCKMON
15-JUL-2015
SHEETDRAWING NOSUBMITTED
SCALE DATE DRAWN CHECK
REVISION BULLETIN 002
NO. DATE DESCRIPTION BY CHECK
JEFFERSON,ARKANSAS 72079
NATIONAL CENTER FOR TOXICOLOGICAL RESEARCH
N C T R
BUILDING 14 RENOVATION
REFLECTED CEILING PLAN - PHASE II
A-10507/15/15
1/8" = 1'-0"
1 REFLECTED CEILING PLAN - PHASE II
TR
UE
N
OR
TH
PL
AN
N O
RT
H
SCALE : 1/8" = 1'-0"
0 4 8 16
1/2" = 1'-0"
2 TYPICAL LAB CEILING
3" = 1'-0"
3 ENLARGED DETAIL AT LAB CEILING
FLOORS
SV-1
EPB-1 DESCO, TROWEL APPLIED EPOXY, GRANITE SERIES #GS-201, 6" HIGH
PTB-1 STONEPEAK SIMPLY MODERN COLLECTION, COLOR: SIMPLY COFFEE
COVE BASE #612C162, 6" X 12"
P-1 SHERWIN WILLIAMS- #SW7009 PEARLY WHITE (NEUTRAL) EGGSHELL
SHERWIN WILLIAMS- #SW7032 WARM STONE (TYPICAL HOLLOW METAL
PAINT) SEMI-GLOSS
ACT-1 ARMSTRONG, ULTIMA HIGH CAC LAY-IN #1951, BEVELED TEGULAR W/ 15/16" GRID, 24" X 24"
RB-1 JOHNSONITE, 4" HIGH RESILIENT BASE, COLOR: FAWN #80CB
P-2
P-3
P-6
CPT-1
EP-1 DESCO, EPOXY FLOORING,GRANITE SERIES #GS-201, COLOR : TBD
SC STAIN: AMERIPOLISH SURELOCK DYE, COLOR: CHOCOLATE BROWN
POLISH: RETROPLATE CONCRETE POLISHING SYSTEM
PT-1 STONEPEAK SIMPLY MODERN COLLECTION, COLOR: SIMPLY
COFFEE #USG1224162, 12" X 24", 30/70 OFFSET INSTALLATION
SVB-1 INTEGRAL COVE BASE TO MATCH SV-1, 6" HIGH
FINISHES LEGEND
BASE
WALLS
CEILINGS
MISCELLANEOUS
MILLWORK
MANNINGTON COMMERICAL FLOORING, BIOSPEC MD, #15240 COOL BEIGE (LC)
CARPET, MODULAR: MANNINGTON COMMERICAL FLOORING, TAKING SHAPE
NOW, COLOR: CHAI LATTE #83098, 24" X 24",RANDOM INSTALLATION METHOD
SHERWIN WILLIAMS- #SW7030 ANEW GRAY (NEUTRAL) EGGSHELL
PT-2 STONEPEAK SIMPLY MODERN COLLECTION, COLOR: SIMPLY TAN
#USG1224164, 12" X 24", 30/70 OFFSET VERTICAL PATTERN
TP-1
TOILET PARTITIONS: SCRANTON PRODUCTS, HINY HIDERS,(HDPE),
COLOR: PARCHMENT
P-5
SHERWIN WILLIAMS #SW7006 EXTRA WHITE (EXPOSED CEILING) DRY FOG
P-4
SHERWIN WILLIAMS EPOXY #SW7009 PEARLY WHITE (LABS AND
RESTROOMS)
SHERWIN WILLIAMS #SW7006 EXTRA WHITE (CEILINGS) THOROCOAT
EP-1 DESCO, EPOXY WALLS,GRANITE SERIES #GS-201, 4' ABOVE BASE
CG-1
WP-1
WOS CONSTRUCTION SPECIALTIES, PEDITREAD SA SYSTEM
TAPERED ANGLE FRAME,COLOR: COLOR ANODIZED
SS-1 CORIAN SOLID SURFACE, COLOR: CONCRETE
INPRO CORP, COLOR: 0119 PEPPERDUST, 4' X 8' SHEETS
INPRO CORP, COLOR: 0119 PEPPERDUST. MODEL G2-150. 3"
1. TOILET PARTITIONS TO BE FLOOR MOUNTED OVERHEAD BRACED WITH TP-1.
2. HOLLOW METAL DOORS AND TRIM TO BE PAINTED AS P-3.
3. GROUT COLORS TO BE AS FOLLOWS: PT-1 TO MATCH EPOXY CUSTOM
BUILDING PRODUCTS "NEW TAUPE" #185 ;
PT-2 TO MATCH NON-SANDED CUSTOM BUILDING PRODUCTS "BONE" #382 .
4. ROLLER SHADES ON ALL EXTERIOR WINDOWS TO BE 3% OPENNESS, MANUAL,
COLOR SELECTED FROM MANUFACTURERS STANDARD OFFERING.
5. SHEET VINYL WELDING RODS TO BE MANNINGTON COMMERCIAL FLOORING
COLOR TO BE #415140 "CAMOUFLAGE" ROD. SEAL WITH QUANTUM GUARD HP.
6. WINDOW SILLS TO RECEIVE SS-1.
7. EPOXY FLOORING AND WALL MATERIAL TO BE TROWEL GRADE "TG".
8. ENTRANCE AREAS AT CORRIDORS 1114A, 1114B,1069A, 1069B, AND VESTIBULE
1000 TO RECEIVE 10'-0" LONG X 6'-0 WIDE ROLL OUT RUBBER MATS
9. CORRIDORS 1001A/B, 1011, 1017, 1038, 1031, 1020, 1046, 1052, AND 1060 TO
RECEIVE WALL PROTECTION STARTING AT THE TOP OF THE BASE AND ENDING AT
4' 4" A.F.F. 4' X 8' SHEETS.
10. CORRIDORS 1001A/B, 1011, 1017, 1038, 1031, 1020, 1046, 1052, 1060, 1114A/B,
1069A/B, AND 1101 TO RECEIVE CORNER GUARDS STARTING AT THE BASE AND
EXTENDING TO 8' 4" A.F.F. GUARDS ARE 8' IN LENGTH AND 3" SURFACE MOUNTED.
11. GLASS WASH 1033: EPOXY TO EXTEND UP WALL TO 4'-0" A.F.F. PAINT ABOVE AS
SCHEDULED.
12. COLUMNS IN CORRIDORS 1069A, 1114B, AND 1102 TO BE PAINTED TO MATCH P-
1 COLOR. PAINT SYSTEM AS SPECIFIED FOR MATERIAL TYPE.
13. WALK-OFF SYSTEM (WOS) IN LOBBIES 1101 AND 1113 TO BE WOS.
GENERAL NOTES:
MATERIAL LEGEND
--- "NO" OR "NONE"
ACT ACOUSTICAL CEILING TILE
CG CORNER GUARD
SC STAINED AND SEALED CONCRETE
CPT CARPET
EPB INTEGRAL EPOXY COVE BASE
EP EPOXY- FLOORING
EPT EPOXY PAINT
EXP EXPOSED STRUCTURE
GWB GYPSUM WALL BOARD
MRGWB MOISTURE RESISTANT GYPSUM WALL BOARD
P PAINT
PT PORCELAIN TILE
PTB PORCELAIN TILE BASE
RB RESILIENT BASE
SVB INTEGRAL SHEET VINYL BASE
SV SHEET VINYL
TP TOILET PARTITIONS
WOM WALK-OFF MAT
WOS WALK-OFF SYSTEM
WP WALL PROTECTION
SS SOLID SURFACE
EXST EXISTING
CMU CONCRETE MASONRY UNIT
MTL METAL PANEL CEILING
CROMWELL
ARCHITECTS/
ENGINEERS
#5A
R
KANSAS -ENG
IN
EE
R
C E R T
IF
IC
AT
EOF
AUTHORIZ
A T
IO
N R
E G
IS
T E
RED A R CH IT E C
T
A R K A N S A S
GREGORY B.
COCKMON
15-JUL-2015
SHEETDRAWING NOSUBMITTED
SCALE DATE DRAWN CHECK
REVISION BULLETIN 002
NO. DATE DESCRIPTION BY CHECK
JEFFERSON,ARKANSAS 72079
NATIONAL CENTER FOR TOXICOLOGICAL RESEARCH
N C T R
BUILDING 14 RENOVATION
ROOM FINISH SCHEDULE - PHASE I
A-60107/15/15
ROOM FINISH SCHEDULE - Phase 1
ROOM
FLOOR BASE
NORTH WALL SOUTH WALL EAST WALL WEST WALL CEILING
NotesNUMBER NAME MATERIAL COLOR MATERIAL COLOR MATERIAL COLOR MATERIAL COLOR MATERIAL COLOR Ceiling Height
1000 VESTIBULE EP-1, WOM EPB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 MTL, EXP P-4, P-6 TIGHT TO DECK
1001A CORRIDOR EP-1 EPB-1 GWB WP-1, P-5 GWB WP-1, P-5 --- --- GWB WP-1, P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1001B CORRIDOR EP-1 EPB-1 EXST P-5 EXST P-5 GWB WP-1, P-5 GWB WP-1, P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1002 ULTRA COOL EP-1 EPB-1 EXST P-5 CMU P-5 CMU P-5 EXST P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1003 OZONE FREE LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1004 CELL CULTURE LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1005 GENERAL PURPOSE LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1006 GC/ICP MASS SPEC LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1007 HPLC LAB 3 SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1008 HPLC LAB 2 SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1009 INHALATION CHEM LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1010 CHEM LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1011 CORRIDOR EP-1 EPB-1 EXST/GWB P-5 GWB P-5 GWB WP-1, P-5 GWB WP-1, P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1012 TMP LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1013 MASS SPEC SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1014 NAN LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1015 CAO LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1016A MOLECULAR BIO LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 --- --- MTL, EXP P-4, P-6 TIGHT TO DECK
1016B GENETICS LAB SV-1 SVB-1 GWB P-5 GWB P-5 --- --- GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1017 CORRIDOR EP-1 EPB-1 EXST/GWB P-5 GWB P-5 GWB WP-1, P-5 GWB WP-1, P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1018 GENERAL STORAGE SV-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 MTL, EXP P-4, P-6 TIGHT TO DECK
1019 BIOCHEM LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1020 CORRIDOR EP-1 EPB-1 GWB WP-1, P-5 GWB WP-1, P-5 --- --- --- --- MTL, EXP P-4, P-6 TIGHT TO DECK
1021 MEN PT-1 PTB-1 GWB P-5 GWB P-5 PT PT-2 PT PT-2 ACT ACT-1 8'-0"
1022 GEN. STORAGE SV-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 MTL, EXP P-4, P-6 TIGHT TO DECK
1023 ICE MACHINE SV-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 MTL, EXP P-4, P-6 TIGHT TO DECK
1024 GPT LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1025 WOMEN PT-1 PTB-1 GWB P-5 GWB P-5 PT PT-2 PT PT-2 ACT ACT-1 8'-0"
1026 SMOKE LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1027 TISSUE CULTURE SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1028 CART STORAGE SV-1 SVB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 MTL, EXP P-4, P-6 TIGHT TO DECK
1030 TELE/DATA SV-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 MTL, EXP P-4, P-6 TIGHT TO DECK
1031 CORRIDOR EP-1 EPB-1 GWB WP-1, P-5 GWB WP-1, P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1032 COMET PRINT SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1033 GLASS WASH SUPPORT EP-1 EPB-1 MRGWB EP-1, P-5 MRGWB EP-1, P-5 MRGWB EP-1, P-5 MRGWB EP-1, P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1033A GLASS WASH EP-1 EPB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1034 CHEMICAL STORAGE SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1035A TC/HPRT LAB SV-1 SVB-1 GWB P-5 --- --- GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1035B FLO CYTOMETRY LAB 2 SV-1 SVB-1 --- --- GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1036 MLA LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1037A FLO CYTOMETRY LAB 3 SV-1 SVB-1 GWB P-5 --- --- GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1037B FLO CYTOMETRY LAB 1 SV-1 SVB-1 --- --- GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1038 CORRIDOR EP-1 EPB-1 GWB/ EXST WP-1, P-5 GWB WP-1, P-5 --- --- --- --- MTL, EXP P-4, P-6 TIGHT TO DECK
1039 TELE/DATA SV-1 SVB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 MTL, EXP P-4, P-6 TIGHT TO DECK
1040 MEN PT-1 PTB-1 GWB P-5 GWB P-5 PT PT-2 PT PT-2 ACT ACT-1 8'-0"
1041 ICE MACHINE SV-1 SVB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 MTL, EXP P-4, P-6 TIGHT TO DECK
1042 WOMEN PT-1 PTB-1 GWB P-5 GWB P-5 PT PT-2 PT PT-2 ACT ACT-1 8'-0"
1043 GENE EXPRESN LAB 1 SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1044 GENE EXPRESN LAB 2 SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1069A CORRIDOR SC, WOM RB-1 GWB P-1 GWB P-2 --- --- GWB P-1 ACT ACT-1 10'-0"
1070 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1071 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1072 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1073 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1074 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1075 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1076 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1077 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1078 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1079 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1080 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1081 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1082 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1083 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1084 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1085 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1086 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1087 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1088 CONFERENCE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1114B CORRIDOR SC, WOM RB-1 GWB P-2 GWB/ EXST P-1 --- --- GWB P-1 ACT ACT-1 10'-0"
1127 CONFERENCE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1128 DIRECTOR'S OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1129 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1130 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1131 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1132 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1133 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1134 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1135 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1136 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1137 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1138 SPRINKLER SC RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1139 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1140 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1141 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1142 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1143 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1144 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1145 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1 1
FLOORS
SV-1
EPB-1 DESCO, TROWEL APPLIED EPOXY, GRANITE SERIES #GS-201, 6" HIGH
PTB-1 STONEPEAK SIMPLY MODERN COLLECTION, COLOR: SIMPLY COFFEE
COVE BASE #612C162, 6" X 12"
P-1 SHERWIN WILLIAMS- #SW7009 PEARLY WHITE (NEUTRAL) EGGSHELL
SHERWIN WILLIAMS- #SW7032 WARM STONE (TYPICAL HOLLOW METAL
PAINT) SEMI-GLOSS
ACT-1 ARMSTRONG, ULTIMA HIGH CAC LAY-IN #1951, BEVELED TEGULAR W/ 15/16" GRID, 24" X 24"
RB-1 JOHNSONITE, 4" HIGH RESILIENT BASE, COLOR: FAWN #80CB
P-2
P-3
P-6
CPT-1
EP-1 DESCO, EPOXY FLOORING,GRANITE SERIES #GS-201, COLOR : TBD
SC STAIN: AMERIPOLISH SURELOCK DYE, COLOR: CHOCOLATE BROWN
POLISH: RETROPLATE CONCRETE POLISHING SYSTEM
PT-1 STONEPEAK SIMPLY MODERN COLLECTION, COLOR: SIMPLY
COFFEE #USG1224162, 12" X 24", 30/70 OFFSET INSTALLATION
SVB-1 INTEGRAL COVE BASE TO MATCH SV-1, 6" HIGH
FINISHES LEGEND
BASE
WALLS
CEILINGS
MISCELLANEOUS
MILLWORK
MANNINGTON COMMERICAL FLOORING, BIOSPEC MD, #15240 COOL BEIGE (LC)
CARPET, MODULAR: MANNINGTON COMMERICAL FLOORING, TAKING SHAPE
NOW, COLOR: CHAI LATTE #83098, 24" X 24",RANDOM INSTALLATION METHOD
SHERWIN WILLIAMS- #SW7030 ANEW GRAY (NEUTRAL) EGGSHELL
PT-2 STONEPEAK SIMPLY MODERN COLLECTION, COLOR: SIMPLY TAN
#USG1224164, 12" X 24", 30/70 OFFSET VERTICAL PATTERN
TP-1
TOILET PARTITIONS: SCRANTON PRODUCTS, HINY HIDERS,(HDPE),
COLOR: PARCHMENT
P-5
SHERWIN WILLIAMS #SW7006 EXTRA WHITE (EXPOSED CEILING) DRY FOG
P-4
SHERWIN WILLIAMS EPOXY #SW7009 PEARLY WHITE (LABS AND
RESTROOMS)
SHERWIN WILLIAMS #SW7006 EXTRA WHITE (CEILINGS) THOROCOAT
EP-1 DESCO, EPOXY WALLS,GRANITE SERIES #GS-201, 4' ABOVE BASE
CG-1
WP-1
WOS CONSTRUCTION SPECIALTIES, PEDITREAD SA SYSTEM
TAPERED ANGLE FRAME,COLOR: COLOR ANODIZED
SS-1 CORIAN SOLID SURFACE, COLOR: CONCRETE
INPRO CORP, COLOR: 0119 PEPPERDUST, 4' X 8' SHEETS
INPRO CORP, COLOR: 0119 PEPPERDUST. MODEL G2-150. 3"
1. TOILET PARTITIONS TO BE FLOOR MOUNTED OVERHEAD BRACED WITH TP-1.
2. HOLLOW METAL DOORS AND TRIM TO BE PAINTED AS P-3.
3. GROUT COLORS TO BE AS FOLLOWS: PT-1 TO MATCH EPOXY CUSTOM
BUILDING PRODUCTS "NEW TAUPE" #185 ;
PT-2 TO MATCH NON-SANDED CUSTOM BUILDING PRODUCTS "BONE" #382 .
4. ROLLER SHADES ON ALL EXTERIOR WINDOWS TO BE 3% OPENNESS, MANUAL,
COLOR SELECTED FROM MANUFACTURERS STANDARD OFFERING.
5. SHEET VINYL WELDING RODS TO BE MANNINGTON COMMERCIAL FLOORING
COLOR TO BE #415140 "CAMOUFLAGE" ROD. SEAL WITH QUANTUM GUARD HP.
6. WINDOW SILLS TO RECEIVE SS-1.
7. EPOXY FLOORING AND WALL MATERIAL TO BE TROWEL GRADE "TG".
8. ENTRANCE AREAS AT CORRIDORS 1114A, 1114B,1069A, 1069B, AND VESTIBULE
1000 TO RECEIVE 10'-0" LONG X 6'-0 WIDE ROLL OUT RUBBER MATS
9. CORRIDORS 1001A/B, 1011, 1017, 1038, 1031, 1020, 1046, 1052, AND 1060 TO
RECEIVE WALL PROTECTION STARTING AT THE TOP OF THE BASE AND ENDING AT
4' 4" A.F.F. 4' X 8' SHEETS.
10. CORRIDORS 1001A/B, 1011, 1017, 1038, 1031, 1020, 1046, 1052, 1060, 1114A/B,
1069A/B, AND 1101 TO RECEIVE CORNER GUARDS STARTING AT THE BASE AND
EXTENDING TO 8' 4" A.F.F. GUARDS ARE 8' IN LENGTH AND 3" SURFACE MOUNTED.
11. GLASS WASH 1033: EPOXY TO EXTEND UP WALL TO 4'-0" A.F.F. PAINT ABOVE AS
SCHEDULED.
12. COLUMNS IN CORRIDORS 1069A, 1114B, AND 1102 TO BE PAINTED TO MATCH P-
1 COLOR. PAINT SYSTEM AS SPECIFIED FOR MATERIAL TYPE.
13. WALK-OFF SYSTEM (WOS) IN LOBBIES 1101 AND 1113 TO BE WOS.
GENERAL NOTES:
MATERIAL LEGEND
--- "NO" OR "NONE"
ACT ACOUSTICAL CEILING TILE
CG CORNER GUARD
SC STAINED AND SEALED CONCRETE
CPT CARPET
EPB INTEGRAL EPOXY COVE BASE
EP EPOXY- FLOORING
EPT EPOXY PAINT
EXP EXPOSED STRUCTURE
GWB GYPSUM WALL BOARD
MRGWB MOISTURE RESISTANT GYPSUM WALL BOARD
P PAINT
PT PORCELAIN TILE
PTB PORCELAIN TILE BASE
RB RESILIENT BASE
SVB INTEGRAL SHEET VINYL BASE
SV SHEET VINYL
TP TOILET PARTITIONS
WOM WALK-OFF MAT
WOS WALK-OFF SYSTEM
WP WALL PROTECTION
SS SOLID SURFACE
EXST EXISTING
CMU CONCRETE MASONRY UNIT
MTL METAL PANEL CEILING
CROMWELL
ARCHITECTS/
ENGINEERS
#5A
R
KANSAS -ENG
IN
EE
R
C E R T
IF
IC
AT
EOF
AUTHORIZ
A T
IO
N R
E G
IS
T E
RED A R CH IT E C
T
A R K A N S A S
GREGORY B.
COCKMON
15-JUL-2015
SHEETDRAWING NOSUBMITTED
SCALE DATE DRAWN CHECK
REVISION BULLETIN 002
NO. DATE DESCRIPTION BY CHECK
JEFFERSON,ARKANSAS 72079
NATIONAL CENTER FOR TOXICOLOGICAL RESEARCH
N C T R
BUILDING 14 RENOVATION
ROOM FINISH SCHEDULE - PHASE II
A-60207/15/15
ROOM FINISH SCHEDULE - Phase 2
ROOM
FLOOR BASE
NORTH WALL SOUTH WALL EAST WALL WEST WALL CEILING
NotesNUMBER NAME MATERIAL COLOR MATERIAL COLOR MATERIAL COLOR MATERIAL COLOR MATERIAL COLOR Ceiling Height
1046 CORRIDOR EP-1 EPB-1 EXST P-5 EXST P-5 GWB WP-1, P-5 EXST WP-1, P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1047 OMIPRINT MS LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1048 MOLECULAR LAB 1 SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1048B CELL LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1049 AMES LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1050 TC LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1051 ACBPCR LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1052 CORRIDOR SV-1 SVB-1 GWB/EXST P-5 EXST P-5 GWB WP-1, P-5 GWB WP-1, P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1053 TC LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1054 PCR LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1055 RAPID B-FLOW CYTOMETRY SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1056 GENERAL STORAGE SV-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 MTL, EXP P-4, P-6 TIGHT TO DECK
1057 MASS SPEC LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1058 LOW CONCENTRATION PREP LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1059 HIGH CONCENTRATION PREP LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1060 CORRIDOR EP-1 EPB-1 EXST P-5 EXST P-5 GWB WP-1, P-5 GWB WP-1, P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1061 ULTRA COOL EP-1 EPB-1 CMU P-5 CMU P-5 CMU P-5 CMU P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1062 CHEMISTRY LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1063 HUMAN SAMPLE PREP SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1065 PENCE MASS SPEC LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1066 CELL CULTURE LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1067 SAMPLE PREP SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1068 PROTEOMICS MASS SPEC LAB SV-1 SVB-1 GWB P-5 GWB P-5 GWB P-5 GWB P-5 MTL, EXP P-4, P-6 TIGHT TO DECK
1089 ENTRY SC, WOM RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1090 VENDING SC RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1091 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1092 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1093 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1094 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1095 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1096 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1097 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1098 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1099 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1100 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1101 LOBBY S.E. SC, WOS RB-1 GWB/EXST P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 14'-0"
1102 CORRIDOR SC RB-1 --- --- --- --- GWB P-2 GWB P-1 ACT ACT-1 10'-0"
1103 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1104 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1105 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1106 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1107 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1108 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1109 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1110 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1111 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1112 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1113 LOBBY N.E. SC RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 14'-0"
1114 STAIR NO WORK
1115 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1116 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1117 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1118 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1119 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1120 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1121 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1122 SPRINKLER SC RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 EXP P-4, P-6 ---
1123 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1124 OFFICE CPT-1 RB-1 GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ACT-1 9'-0"
1125 VENDING SC RB-1 GWB P-1 --- --- GWB P-1 --- --- ACT ACT-1 9'-0"
1126 ENTRY SC, WOM RB-1 GWB P-1 --- --- GWB --- EXST P-1 ACT ACT-1 9'-0"
NCTR-Building 14 Renovation 2015-056 Jefferson, Arkansas July 2015
METAL PANELS
PR002 07 42 13 - 1
SECTION 07 42 13
METAL PANELS
PART 1 GENERAL
1.01 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
1.02 RELATED REQUIREMENTS
A. Division 01 for related LEED general requirements.
B. Division 07 Section "Sheet Metal Flashing and Trim" for sheet metal copings, flashings, reglets and roof drainage items.
C. Division 07 Section "Joint Sealants" for field-applied joint sealants.
1.03 REFERENCES
A. American Architectural Manufacturer's Association (AAMA):
1. AAMA 501.1 - Test Method for Water Penetration of Windows, Curtain Walls and Doors Using Dynamic Pressure.
2. AAMA 620 - Voluntary Specification for High Performance Organic Coatings on Coil Coated Architectural Aluminum Substrates.
3. AAMA 621 - Voluntary Specification for High Performance Organic Coatings on Coil Coated Architectural Hot Dipped Galvanized (HDG) and Zinc-Aluminum Coated Steel Substrates.
B. American Society of Civil Engineers (ASCE):
1. ASCE 7 - Minimum Design Loads for Buildings and Other Structures.
C. ASTM International (ASTM):
1. ASTM A 653/A 653M - Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron
Alloy-Coated (Galvannealed) by the Hot-Dip Process.
2. ASTM A 755/A 755M - Specification for Steel Sheet, Metallic Coated by the Hot-Dip
Process and Prepainted by the Coil-Coating Process for Exterior Exposed Building Products.
3. ASTM B 209 - Specification for Aluminum and Aluminum Alloy Sheet and Plate.
4. ASTM C 754 - Specification for Installation of Steel Framing Members to Receive Screw
Attached Gypsum Panel Products.
5. ASTM C 920 - Specification for Elastomeric Joint Sealants.
6. ASTM C 1007 - Standard Specification for Installation of Load Bearing (Transverse and
Axial) Steel Studs and Related Accessories.
7. ASTM E 72 - Standard Test Methods of Conducting Strength Tests of Panels for Building
Construction.
8. ASTM E 283 - Test Method for Determining the Rate of Air Leakage Through Exterior
Windows, Curtain Walls, and Doors under Specified Pressure Differences across the Specimen.
9. ASTM E 331 - Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference.
D. Sheet Metal and Air Conditioning Contractors National Association, Inc. (SMACNA):
1. Architectural Sheet Metal Manual.
1.04 PERFORMANCE REQUIREMENTS
A. General: Provide metal wall panel assemblies meeting performance requirements as determined by application of specified tests by a qualified testing agency on manufacturer's standard assemblies.
B. Air Infiltration: Maximum 0.06 cfm/sq. ft. (0.3 L/s per sq. m) per ASTM E 283 at a static-air-pressure difference of 1.57 lbf/sq. ft. (75 Pa), using minimum 10-by-10 foot (3050-by-3050 mm) test panel that includes side joints.
METAL PANELS
PR002 07 42 13 - 2
C. Thermal Movements: Allow for thermal movements from variations in both ambient and internal temperatures. Accommodate movement of support structure caused by thermal expansion and contraction.
1.05 QUALITY ASSURANCE
A. Manufacturer/Source: Provide metal wall panel and panel accessories from a single manufacturer.
B. Manufacturer Qualifications: Approved manufacturer listed in this Section with minimum 10 years experience in manufacture of similar products in successful use in similar applications.
1. Approval of Comparable Products: Submit the following in accordance with project substitution requirements, within time allowed for substitution review:
a. Product data, including certified independent test data indicating compliance with requirements.
b. Sample submittal from similar project.
c. Project references: Minimum of 5 installations not less than 5 years old, with owner and architect contact information.
d. Sample warranty.
2. Substitutions following award of contract are not allowed except as stipulated in Division 01 General Requirements.
3. Approved manufacturers must meet separate requirements of Submittals Article.
C. Installer Qualifications: Experienced Installer with minimum of 5 years experience with successfully completed projects of a similar nature and scope.
1.06 ADMINISTRATIVE REQUIREMENTS
A. Preinstallation Meeting: Conduct preinstallation meeting at site attended by Construction Manager - Advisor, Architect Engineer, manufacturer's representative, and other trade contractors.
1. Coordinate building framing in relation to metal wall panel assembly.
2. Coordinate window, door and louver, mechanical, plumbing penatrations, other openings and penetrations of metal wall panel assembly.
1.07 ACTION SUBMITTALS
A. Product Data: Manufacturer's data sheets, for specified products.
1. Include data indicating compliance with performance requirements, including load span tables tested for side joint disengagement under negative loads per ASTM E 72.
B. Shop Drawings: Provide shop drawings prepared by manufacturer or manufacturer's authorized
Installer. Include full elevations showing openings and penetrations. Include details of each condition of installation and attachment. Provide details at a minimum scale 1-1/2-inch per foot (1:8) of all required trim and extrusions needed for a complete installation.
1. Indicate points of supporting structure that must coordinate with metal wall panel assembly installation.
C. Samples for Initial Selection: For each product specified. Provide representative color charts of manufacturer's full range of colors.
D. Samples for Verification: Provide 12-inch (300 mm) section of panel(s) showing finishes.
Provide 12-inch (300 mm) long pieces of trim pieces and other exposed components.
1.08 INFORMATIONAL SUBMITTALS
A. Product Test Reports: Indicating compliance of products with requirements, from a qualified independent testing agency.
B. Qualification Information: For Installer firm.
C. Manufacturer's warranty: Submit sample warranty.
1.09 CLOSEOUT SUBMITTALS
A. Maintenance data.
METAL PANELS
PR002 07 42 13 - 3
1.10 DELIVERY, STORAGE, AND HANDLING
A. Protect metal wall panel products during shipping, handling, and storage to prevent staining, denting, deterioration of components or other damage.
1. Deliver, unload, store, and erect metal wall panel products and accessory items without misshaping panels or exposing panels to surface damage from weather or construction operations.
1.11 WARRANTY
A. Special Manufacturer's Warranty: On manufacturer's standard form, in which manufacturer agrees to repair or replace components of metal wall panel assemblies that fail in materials and workmanship within two years from date of Substantial Completion.
B. Special Panel Finish Warranty: On manufacturer's standard form, in which manufacturer agrees to repair or replace metal wall panels that evidence deterioration of finish within the following periods from the date of substantial completion:
1. Warranty Period: 20 years.
PART 2 PRODUCTS
2.01 MANUFACTURERS
A. Basis of Design: CENTRIA, IW Series Metal Wall Panels. Provide basis of design product, or comparable product approved by Architect Engineer prior to bid.
1. CENTRIA Architectural Systems; Moon Township, PA 15108-2944. Tel: (800)759-7474.
Tel: (412)299-8000. Fax: (412)299-8317. Email: info@CENTRIA.com <mailto:info@CENTRIA.com>. Web: www.CENTRIA.com <http://www.CENTRIA.com>.
B. Acceptable Manufacturers:
1. MBCI; www.mbci.com
2.02 METAL PANEL MATERIALS
A. Smooth Prefinished Steel Face Sheet: Coil-coated, ASTM A 755/A 755M.
1. Galvanized Steel Sheet: ASTM A 653/A 653M, G90 (Class Z275), structural steel quality.
2. Face Sheet: Minimum 0.91 mm/20 gage single span nominal uncoated thickness.
2.03 CONCEALED FASTENER METAL PANELS
A. Metal Wall Panels, General: Factory-formed, concealed fastener panels with interconnecting side joints, fastened to supports with concealed fasteners, with factory-applied sealant in side laps when required to meet performance requirements.
B. Type IW-10A; Flush-joint profile with raised flat pan:
1. Basis of Design Product: CENTRIA, IW-10A.
2. Panel Coverage: 12 inches.
3. Panel Height: 1.50 inches.
2.04 METAL PANEL ACCESSORIES
A. Metal Wall Panel Accessories, General: Provide complete metal wall panel assembly incorporating trim, copings, fasciae, parapet caps, soffits, sills, inside and outside corners, and miscellaneous flashings. Provide manufacturer's factory-formed shims, flashings, gaskets, lap strips, closure strips, and caps for a complete installation. Fabricate accessories in accordance with SMACNA Manual.
B. Extruded Trim: Manufacturer's complementary aluminum extrusions for head, jamb, sill, base, flush, reveal, inside and outside corner, endwall, and expansion joint details. Finish to match metal wall panels.
1. Basis of Design: CENTRIA, Microline Extrusions.
C. Mitered Corners: Structurally-bonded horizontal interior and exterior trimless corners matching metal wall panel material, profile, and factory-applied finish, fabricated and finished by metal wall panel manufacturer.
METAL PANELS
PR002 07 42 13 - 4
1. Welded, riveted, fastened, or field- fabricated corners do not meet the requirements of this specification.
2. Basis of Design: CENTRIA, MicroSeam Corners.
D. Formed Flashing and Trim: Match material, thickness, and color of metal wall panels.
E. Sealants: Type recommended by metal wall panel manufacturer for application, meeting requirements of Division 07 Section "Joint Sealants."
F. Flashing Tape: 4-inch wide self-adhering butyl flashing tape.
G. Fasteners: Self-tapping screws and other acceptable fasteners recommended by panel manufacturer. Where exposed fasteners cannot be avoided, supply corrosion-resistant fasteners with heads matching color of metal wall panels by means factory-applied coating.
2.05 SECONDARY METAL SUBGIRT FRAMING
A. Miscellaneous Framing Components, General: Cold-formed metallic-coated steel sheet, ASTM
A 653/A 653M, G90 (Z180).
1. Hat Channels: 0.053 inch/16 ga. (1.34 mm) minimum.
2. Sill Channels: 0.053 inch/16 ga. (1.34 mm) minimum.
2.06 METAL PANEL FINISHES
A. Color:
1. Exterior Surface: Kynar finish as selected by Architect Engineer from manufacturer's standard colors.
PART 3 EXECUTION
3.01 EXAMINATION
A. Examine metal wall panel substrate with Installer present. Inspect for erection tolerances and other conditions that would adversely affect installation of metal wall panels.
B. Wall Substrate: Confirm that wall substrate is within tolerances acceptable to metal wall panel system manufacturer.
1. Maximum substrate and framing deviations from flat plane acceptable:
a. 1/4-inch in 20 feet vertically or horizontally.
b. 1/2-inch across building elevation.
c. 1/8-inch in 5 feet.
C. Framing: Inspect framing that will support metal wall panels to determine if support components are installed as indicated on approved shop drawings. Confirm presence of acceptable framing members at recommended spacing to match installation requirements of metal wall panels.
D. Openings: Verify that window, door, louver and other penetrations match layout on shop drawings.
E. Correct out-of-tolerance work and other deficient conditions prior to proceeding with metal wall panel system installation.
3.02 SECONDARY FRAMING INSTALLATION
A. Secondary Metal Subgirt Framing: Install secondary metal framing components to tolerances indicated, as shown on approved shop drawings. Install secondary metal framing and other metal panel supports per ASTM C 1007 and metal wall panel manufacturer's recommendations.
3.03 METAL PANEL INSTALLATION
A. General: Install metal wall panels in accordance with approved shop drawings and manufacturer's recommendations. Install metal wall panels in orientation, sizes, and locations indicated. Anchor metal wall panels and other components securely in place. Provide for thermal and structural movement
B. Attach panels to metal framing using recommended clips, screws, fasteners, sealants, and adhesives indicated on approved shop drawings.
METAL PANELS
PR002 07 42 13 - 5
1. Fasteners for Steel Wall Panels: Stainless-steel for exterior locations and locations exposed to moisture; carbon steel for interior use only.
2. Fasten metal wall panels to supports with fasteners and spacing recommended by manufacturer.
3. Provide weatherproof escutcheons for pipe and conduit penetrating exterior walls.
4. Dissimilar Materials: Where elements of metal wall panel system will come into contact with dissimilar materials, treat faces and edges in contact with dissimilar materials as recommended by manufacturer.
C. Joint Sealers: Install joint sealants where indicated on approved shop drawings.
3.04 ACCESSORY INSTALLATION
A. General: Install metal wall panel accessories with positive anchorage to building and provide for thermal expansion. Coordinate installation with flashings and other components.
1. Install related flashings and sheet metal trim per requirements of Division 07 Section
"Sheet Metal Flashing and Trim."
2. Install components required for a complete metal wall panel assembly, including trim, copings, corners, lap strips, flashings, sealants, fillers, closure strips, and similar items.
3. Comply with performance requirements and manufacturer's written installation instructions.
4. Provide concealed fasteners except where noted on approved shop drawings.
5. Set units true to line and level as indicated.
3.05 FIELD QUALITY CONTROL
A. Manufacturer's Field Service: Engage a service representative authorized by metal wall panel manufacturer to inspect completed installation. Submit written report.
B. Correct deficiencies noted in manufacturer's report.
3.06 CLEANING AND PROTECTION
A. Remove temporary protective films. Clean finished surfaces as recommended by metal wall panel manufacturer. Clear weep holes and drainage channels of obstructions, dirt, and sealant.
Maintain in a clean condition during construction.
B. Replace damaged panels and accessories that cannot be repaired by finish touch-up or minor repair.
END OF SECTION
| 2015_056-Arch_eferris@cromwell.com - Sheet - A-104 - REFLECTED CEILING PLAN - PHASE I |
| Sheets |
| A-104 - REFLECTED CEILING PLAN - PHASE I |
| 2015_056-Arch_eferris@cromwell.com - Sheet - A-105 - REFLECTED CEILING PLAN - PHASE II |
| Sheets |
| A-104 - REFLECTED CEILING PLAN - PHASE I |
| A-105 - REFLECTED CEILING PLAN - PHASE II |
| 2015_056-Arch_eferris@cromwell.com - Sheet - A-601 - ROOM FINISH SCHEDULE - PHASE I |
| Sheets |
| A-104 - REFLECTED CEILING PLAN - PHASE I |
| A-105 - REFLECTED CEILING PLAN - PHASE II |
| A-601 - ROOM FINISH SCHEDULE - PHASE I |
| A-602 - ROOM FINISH SCHEDULE - PHASE II |
| 2015_056-Arch_eferris@cromwell.com - Sheet - A-602 - ROOM FINISH SCHEDULE - PHASE II |
| Sheets |
| A-104 - REFLECTED CEILING PLAN - PHASE I |
| A-105 - REFLECTED CEILING PLAN - PHASE II |
| A-601 - ROOM FINISH SCHEDULE - PHASE I |
| A-602 - ROOM FINISH SCHEDULE - PHASE II |
07 42 13 - Metal Panels
File details come from the government source that posted it. Updated .