This document is a Statement of Work detailing the results of surveys conducted on a multi-unit residential building, Building 168, located on the Standing Rock Indian Reservation in Fort Yates, North Dakota. The surveys identified various hazards in the building including lead-based paint, asbestos-containing materials, high radon levels, and extensive mold growth. The document provides detailed information on the location, year built, square footage, and specific hazards found in each unit of the 4-plex building. It also includes recommendations for abatement and remediation of the identified issues. This Statement of Work appears to be related to a larger Environmental Remediation Services contract opportunity issued by the Department of the Interior Bureau of Indian Affairs.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statement of Work - Enclosure 2
Standing Rock Bldg 168 Survey Compilation - Revised July 16, 2019
LOCATION NAME: STANDING ROCK COMMUNITY SCHOOL
LOCATION CITY AND STATE: FORT YATES, ND.
SITE WORK DATE: NOVEMBER 2008 (LBP SURVEY)
FINAL REPORT DATE: MARCH 2009 (LBP SURVEY) APRIL 2013 (ASBESTOS, RADON, AND MOLD SURVEY)
SURVEY CONDUCTED BY: LEGEND TECHNICAL SERVICES, INC.
STRUCTURE #
YEAR
BUILT
SQUARE
FOOTAGE
HAZARDS REMARKS
LBP detected on stairway balusters in stairway. Abate and replace per SOW.
Asbestos Survey 6/32 samples tested positive. Remove and dispose of all ACM materials. Joint compound(ceilings and walls)/location: throughout the apartment (includes main level and upper level)
Radon Survey First floor living room detected 2.1pCi/I. Basement 9.1pCi/I. Basement level exceeds the EPA 4.0pCi/I guideline.
Mold Survey
Heavy mold growth was observed on the GWB walls and ceilings throughout the residence. Residence appears to have been vacant for some time with no power and heat. All finish materials within the unit had moisture damage. Water stains and mold growth was observed on the fiberglass pipe insulation in the dirt floor crawlspace and on the wood floor joists in the crawlspace.
LBP detected on stairway balusters in stairway. Abate and replace per SOW.
Asbestos Survey 5/20 samples tested positive. Remove and dispose of all ACM materials. Joint compound(ceilings and walls)/location: throughout the apartment (includes main level and upper level).
Radon Survey First floor living room detected 0.6pCi/I. A radon sample in the crawlspace was collected, however, the sample results are not provided for this unit.
Mold Survey
The dirt floor crawlspace located in the living room closet smelled musty. Mold growth observed on the fiberglass pipe insulation and water intrusions on the wood floor joists to the main floor appears to be from foundation seepage and high humidity levels in crawlspace. 2 buckets full of water located under the kitchen sink, it appears there is a leak from the kitchen sink/pipe. Deteriorated GWB observed on the South wall and ceiling above the kitchen sink can be attributed to moisture generated by cooking in kitchen or leak from 2nd floor bathroom. Black stains and heavy areas of cob webs are visible from the top of the stairwell landing due to lack of cleaning as area is high up and hard to reach.
LBP Survey No LBP detected
Asbestos Survey 8/35 samples tested positive. Remove and dispose of all ACM materials. Joint compound(ceilings and walls)/location: throughout the main floor of the house. Light liner/location: 2nd floor north bedroom.
Radon Survey First floor living room detected 0.9pCi/I. Basement 5.3pCi/I. Basement furnace room level exceeds the
EPA 4.0pCi/I guideline.
Mold Survey
The dirt floor crawlspace located in the living room closet smelled musty. Mold observed on the fiberglass pipe insulation and water intrusions on the wood floor joists to the main floor appears to be from foundation seepage and high humidity levels in crawlspace. Deteriorated GWB observed on the
South wall and ceiling above the kitchen sink attributed to moisture generated by cooking in kitchen or leak from 2nd floor bathroom. Light mold growth was observed on the GWB walls and ceiling in the bathroom presumably due to condensation from lack of exhaust fan. Black stains and heavy areas of cob webs are visible from the top of the stairwell landing due to lack of cleaning as area is high up and hard to reach.
LBP Survey No LBP detected
Asbestos Survey 6/40 samples tested positive. Remove and dispose of all ACM materials. Joint compound(ceilings and walls)/location: throughout the apartment (includes main level and upper level).
Radon Survey First floor living room detected 0.6pCi/I. Basement 8.4pCi/I. Basement level exceeds the EPA 4.0pCi/I guideline.
Mold Survey
The dirt floor crawlspace located in the living room closet smelled musty. Mold growth observed on the fiberglass pipe insulation and water intrusion on the wood floor joists to the main floor appears to be from foundation seepage and high humidity levels in crawlspace. The dirt floor in the crawlspace was also noted to be wet. Light mold growth was observed on the GWB walls near the bathtub and
GWB ceiling in the bathroom presumably due to condensation from lack of exhaust fan. Black stains and heavy areas of cob webs are visible from the top of the stairwell landing due to lack of cleaning as area is high up and hard to reach. Deteriorated GWB walls observed under the windows in the second floor bedrooms appears to be from old or faulty windows and condensation from windows in the winter.
RISK ASSESSMENT
LBP Survey
LBP Survey 168A 4 PLEX 1967 1388ft²
168B 4 PLEX 1967 1388ft²
168C 4 PLEX 1967 1388ft²
168D 4 PLEX 1967 1388ft²