10 L 16 SOW ATT 12 2019 REINSPECTION OF LAFAYETTE BLDG.pdf

PDF 5 MB Posted

Attached to
National Elevator Modernization & Construction IDIQ for Task Orders over $1 Million
Solicitation number
47PM1124R0011
Issued by

About this file

This document provides details for an indefinite delivery/indefinite quantity (IDIQ) multiple award contract solicitation for elevator modernization and construction task orders valued over $1 million. The solicitation will result in separate IDIQ contracts for individual task orders, with a base year and four option periods not to exceed $650 million total. Task orders will be issued by the General Services Administration for modernization work. Responses to the draft solicitation are requested by April 11, 2024, with questions to be submitted to the named contracting staff. Two initial task order attachments are provided for site visits. The solicitation and resultant contracts will establish contracts for individual task orders over $1 million in value.

View the file

Other files

File Type Posted
10 H 08 SECTION 01546 SAFETY AND HEALTH.pdf PDF
10 17 IDIQ attachment Small Business Participation Plan_SBPP_Template .docx DOCX document
10 13 Past Performance_Customer Surveys.pdf PDF
10 08 IDIQ attachment CIO 2180.2 GSA Rules of Behavior for Handling Personally Identifiable Information PII.pdf PDF
10 L 18 SOW ATT 14 PIB 21 06 PIV Card Management Training Final.pdf PDF
10 L 1 Table of Contents.pdf PDF
10 L 0 SF18 Lafayette Elevator.pdf PDF
10 10 IDIQ attachment Reps and Certifications.pdf PDF
10 H 06 Hazmat DC0092ZZ 2023 O M Inspection of Robert C Weaver.pdf PDF
10 16 IDIQ attachment SF24 23a.pdf PDF
10 L 15 SOW ATT 11 Key Sustaniable Products.pdf PDF
10 L 9 SOW ATT 5 CD Waste Mgmt Plan TEMPLATE.pdf PDF
10 L 5 SOW ATT 1 Section 01546_October_2007.pdf PDF
10 02 IDIQ attachment Section 02085 Asbestos Abatement Procedures.pdf PDF
10 L 8 SOW ATT 4 Section 211313 GSA Guide Specification Wet Pipe Sprinkler.pdf PDF
10 L 14 SOW ATT 10 GSA Affiliated Customer Account GACA.pdf PDF
10 03 IDIQ attachment Section 02085 Roofing.pdf PDF
10 00 IDIQ attachment NDA_Document_Security.pdf PDF
10 15 IDIQ attachment IDIQ Pricing Sheet_for eval purposes.xlsx XLSX spreadsheet
10 L 19 Wage Determination.pdf PDF
10 H 07 Hazmat DC0092ZZ CONVERTERS ACM 1 23 07.pdf PDF
10 14 IDIQ attachment Bonding Insurance Geography Qualification Sheet.xlsx XLSX spreadsheet
10 H 10 Vol2 1999 Robert C Weaver Fed Building Historic Structure Report.pdf PDF
10 H 09 Vol1 1999 Robert C Weaver Fed Building Historic Structure Report.pdf PDF
10 L 7 SOW ATT 3 Section 02090 REMOVAL AND DISPOSAL OF LEAD BASED PAINT.pdf PDF
10 L 12 SOW ATT 8 DB Schedule Detailed Small Project 07022018.pdf PDF
10 L 2 SOW 2023 10 11.pdf PDF
10 H 05 Hazmat Bulk Sampling Test Report Submittal_11 1 16.pdf PDF
10 L 6 SOW ATT 2 Section 02085 Asbestos Abatement .pdf PDF
10 H 01 02085-Asbestos April 2013.pdf PDF
10 H 12 HUD Elevator Modernization Draft Bid Sheet.xlsx XLSX spreadsheet
10 L 17 SOW ATT 13 LAFAYETTE HISTORIC STRUCTURE REPORT 7 1986.pdf PDF
10 01 IDIQ attachment Section 01546 Safety and Health Specification.pdf PDF
10 H 02 02090-ControlofLBP January_2013.pdf PDF
10 06 IDIQ attachment PIB 18 02 Attachment 6 File Naming.pdf PDF
10 L 10 SOW ATT 6 CD WasteMonthly Report TEMPLATE.pdf PDF
10 05 IDIQ attachment Section 02090 Control of Lead Based Paint Specification.pdf PDF
10 09 ADM 2181 1 Homeland Security Presidential Directive 12 Personal Identity Verification for Contractor Employees.pdf PDF
10 11 IDIQ attachment GSA 527 Contractors Qualifications and Financial Information.pdf PDF
10 12 IDIQ attachment Past Performance.xlsx XLSX spreadsheet
10 H 00 HUD Elevator Modernization Draft SOW.pdf PDF
10 INFORMATIONAL not official attachment GACA__GSAAffiliatedCustomerAccounts_May_2016v2.pdf PDF
10 H 04 Hazmat ASBESTOS-8987_FINAL CLEARANCE AIR MONITORING VISUAL INSPECTION REPORT_10 19 2015.pdf PDF
10 H 03 CD Waste Mgmt Plan.xlsx XLSX spreadsheet
10 H 11 Weaver Building Elevator Study_100_ Submission_COMBINED_ALL.pdf PDF
10 04 IDIQ attachment Section 02087 Removal of Bird and Bat Droppings.pdf PDF
10 07 IDIQ attachment ADM 7002.1 GSA Smart Buildings.pdf PDF
10 L 13 SOW ATT 9 Elevator Final Study DLR.pdf PDF
10 National Elevator IDIQ RFP and Agreement 2024 03 17.pdf PDF
10 H ZZ HUD Programatic Agreement signed.pdf PDF
Show 40 more

Latest 50 of 52 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

2019 OPERATIONS AND MAINTENANCE

INSPECTION REPORT

LAFAYETTE BUILDING

(DC0026ZZ)

811 Vermont Avenue, NW Washington, D.C. 20009

Prepared for

GENERAL SERVICES ADMINISTRATION

Safety, Environment, and Fire Protection Branch

National Capital Region 301 7th Street, S.W., Room 6929

Washington, D.C., 20407

Submitted by

Rambin Global JV 6401 Golden Triangle Drive, Suite 304

Greenbelt, MD 20770

December 26, 2019

Contract No. 47PM0618D0014 PDN No. EP-47PM0919F0146 Order No. 47PM0919F0146

Reviewed by:

Judi Todd Darnell Dr. Channa Bambaradeniya, CIH Director of Operations Certified Industrial Hygienist

General Services Administration 2019 O&M Inspection Report Lafayette Building (DC0026ZZ) Rambin Global JV Project # GSA-02 i

Executive Summary Rambin Global, Joint Venture (RGJV) conducted a reinspection (visual) at the Lafayette Building located at 811 Vermont Avenue, NW Washington, D.C. 20009 on November 22, 2019. This reinspection was conducted as per the General Services Administration’s (GSA’s) scope of work and in accordance with Asbestos Hazard Emergency Response Act (AHERA) Protocols.

The survey was based on previous reinspection reports submitted to RGJV by GSA.

The following material is confirmed as asbestos-containing materials (ACM):

Duct Insulation on Penthouse Elevator Machine Room

The following eight materials are presumed asbestos-containing materials (PACM):

Drywall Ceilings Fire Doors 4” White Baseboard and Associated Mastic Yellow Carpet Mastic Linoleum Flooring (Gray with Swirls and Waves) Linoleum Flooring (Grey Wave/Line Patterned) Grey Sink Undercoating Elevator Brake Shoes

Eight materials are non-ACM per PLM Analysis. A summary of those materials is provided in the Findings section of this report.

All accessible areas were surveyed to identify and assess the condition of ACBMs as part of this reinspection.

The survey information and updates, along with any other observations, are provided in the Findings and Recommendations of this report. To assist GSA with budgeting, approximate abatement costs are provided.

ii

Table of Contents

EXECUTIVE SUMMARY I

TABLE OF CONTENTS II

1.0 INTRODUCTION 1

2.0 METHODOLOGY 2

2.1 ASSESSMENTS 2

3.0 FINDINGS 4

4.0 RECOMMENDATIONS 5

APPENDIX A - ASBESTOS-CONTAINING MATERIAL INVENTORY

APPENDIX B – PRESUMED ASBESTOS-CONTAINING INVENTORY

APPENDIX C – NON-ASBESTOS-CONTAINING INVENTORY

APPENDIX D – LABORATORY ANALYTICAL RESULTS

APPENDIX E – GSA INSPECTION FORMS

APPENDIX F – INSPECTOR ACCREDITATION

APPENDIX G – 2019 INVENTORY OF ACM AND PACM, MATERIAL ASSESSMENT, AND APPROXIMATE

ABATEMENT COSTS

1.0 Introduction

In accordance with our Industrial Hygiene Services contract with the General Services Administration (GSA), Rambin-Global, JV (RGJV) completed the 2019 Asbestos Hazard Emergency Response Act (AHERA) Operations and Maintenance (O&M) survey of the Lafayette Building (DC0026ZZ) on November 22, 2019. The Lafayette Building is located at 811 Vermont Avenue, NW Washington D.C. The purpose of the survey was to assess previously-identified asbestos-containing materials (ACMs), to sample and confirm the asbestos content of presumed asbestos-containing materials, and to identify and sample any additional suspect ACMs not previously-identified. Sampling within the Lafayette Building was limited to 20 samples per the contract’s scope of work. GSA provided RGJV with TTL ARC Environmental JV’s 2016 reinspection report. A list of previous abatement activities was not available.

Mr. Sameera Meegoda, an EPA and Maryland-accredited AHERA Inspector (#19011111), with reciprocity in Washington, D.C., conducted the reinspection. The Inspector’s certifications are provided in Appendix F.

Survey and reinspection protocols were based on those adopted by the U.S. Environmental Protection Agency (EPA) as detailed in the Asbestos Hazard Emergency Response Act (AHERA; 40 CFR 763, Subpart E), and guidelines detailed by GSA.

2.0 Methodology

RGJV conducted the asbestos survey under protocols established by USEPA 40 Code of Federal Regulations (CFR) 763 Asbestos Hazard Emergency Response Act (AHERA) and 40 CFR 61 Subpart M, National Emission Standards for Hazardous Air Pollutants (NESHAP). GSA-established protocols for asbestos bulk sampling were followed during the survey.

When possible, suspect materials, according to AHERA, that were homogeneous in nature (i.e., uniform in color and texture, installation date) were identified, touched to determine friability, and sampled by removing a small piece. Extreme care was taken to avoid potential fiber release during the inspection/sampling process. Before sample collection, a fine mist of water was typically applied to the sample site. Samples were collected using sharpened core samplers and/or razor knives, where necessary, and immediately placed in labeled containers and sealed. Any dust generated was wet-wiped to minimize the potential for fiber release. Samples were not collected from occupied rooms. The location (selected at random), condition, and quantity of each homogeneous material were recorded in the inspector’s log.

During the survey RGJV collected a total of fifteen (15) bulk samples of five suspect materials. The bulk samples were submitted, along with the corresponding chain-of-custody documentation, to AMA Analytical Services, Inc, a National Voluntary Laboratory Accreditation Program (NVLAP) accredited-laboratory, of Lanham, MD, to determine the presence of asbestos in the sampled materials. Quantification of asbestos content in bulk samples was performed via EPA 600/R-93/116 Method using Polarized Light Microscopy (PLM). The EPA, the Occupational Health and Safety Administration (OSHA), and the District’s Department of Energy and Environment (DOEE) define an ACM as any material containing greater than 1% asbestos.

2.1 Assessments

Assessment of friable ACBM was performed in accordance with Section 763.88 of 40 CFR, Part 763, Subpart E (AHERA). Numerous factors were considered for each homogeneous ACBM in each inspected functional space so as to group each ACBM into one of the seven AHERA assessment categories. Specific factors considered in assessing ACBM conditions included:

Friability Proximity to air plenum/stream Physical condition and extent Accessibility to building occupants of damage: Potential for damage

- Water damage

- Contact damage

- Deterioration

Inaccessible areas could be addressed only through extrapolation of conditions in accessible building space and review of building plans, specifications, or other building documents provided to RGJV. Such inaccessible areas might include but are not limited to:

Within walls Within fire doors Enclosed pipe/duct chases Inside mechanical equipment/ductwork Above plaster ceilings Behind doors that cannot be opened High areas beyond reach of 12-foot ladders

Limited access areas such as those beneath fixed or wall-to-wall carpeting, or above fixed ceilings with small access hatches, etc. were investigated as feasible. Conclusions regarding the presence or absence of asbestos in these areas might be of limited accuracy.

Suspect ACBMs were classified as per § 763.88 of the AHERA Rule, into one of the following seven-hazard assessment categories:

1. Damaged or significantly damaged TSI ACBM

2. Damaged friable surfacing ACBM

3. Significantly damaged friable surfacing ACBM

4. Damaged or significantly damaged friable miscellaneous ACBM

5. ACBM with potential for damage

6. ACBM with potential for significant damage

7. Any remaining friable ACBM or friable suspected ACBM

3.0 Findings

Based on the laboratory analytical results, one material sampled during the 2019 survey were confirmed to be asbestos-containing by PLM analysis. The following lists include all materials noted and/or assessed by RGJV’s Inspector.

Details of confirmed asbestos-containing materials, including photos, are provided in Appendix A. Details for presumed ACM is summarized in Appendix B. Details for those materials which do not meet the definition of asbestos-containing, and can be handled without any sort of asbestos-training are provided in Appendix C.

Current and previous (when feasible) analytical results may be found in Appendix D. GSA’s Asbestos Assessment Data Forms are provided as Appendix E.

Confirmed ACM

Duct Insulation in Penthouse Elevator Machine Room

PACM

Drywall Ceilings Fire Doors 4” White Baseboard and Associated Mastic Yellow Carpet Mastic Linoleum Flooring (Gray with Swirls and Waves) Linoleum Flooring (Grey Wave/Line Patterned) Grey Sink Undercoating Elevator Brake Shoes

Confirmed Non-ACM

Sprayed-on Fire Proofing (Tan) on I-Beam 12"x12" Floor Tile (White with Gray Streaks) Fire Stop (Red) on Pipe Penetrations Seam Sealant (Off-white) on Paper wraps on Fiberglass Pipe Insulation Seam sealant (gray) on bare metal duct joint Drywall and associated Joint Compound Black grainy (foam) pipe insulation Gray sprayed-on fire proofing

4.0 Recommendations

Any planned renovations or maintenance activities that will disturb known and suspect ACBM (and potentially render them friable) will require the proper response action of abatement, encapsulation, enclosure, and/or repair by AHERA and DOEE-accredited and trained personnel. All ACBM and PACM must be maintained in place, unless removed, in accordance with the O&M plan. All assumed ACBM(s) must be sampled prior to any disturbance to verify the presence of asbestos by an AHERA and DOEE-accredited certified Inspector and analyzed by a NIST/NVLAP accredited laboratory.

Specific material condition and response actions are provided in the table presented in Appendix G.

APPENDIX A – ASBESTOS-CONTAINING MATERIAL INVENTORY

Asbestos-Containing Materials Identified During the 2019 Survey

HA

Material

Description Location

Estimated Quantity

Sample Number Results Photograph

GSA-

LAFA-01

Duct Insulation (White - Fibrous)

Penthouse Elevator Machine Room

500 SF

GSA-LAFA-

01A, 01B, 01C 60% Chrysotile

APPENDIX B – PRESUMED ASBESTOS-CONTAINING MATERIAL

INVENTORY

Presumed Asbestos-Containing Materials Inventory

Material

Description Location

Estimated Quantity

Photograph

GSA-

LAFA-06

Drywall Ceiling Throughout the

Building

15,177 SF

LAFA-07

Fire Doors Throughout the

69 Each

LAFA-08

4” White Baseboard and

Associated Mastic

Throughout the

9,971 LF

LAFA-09

Yellow Carpet Mastic

USA 12 Conference Room, GSA-11, GSA Cubicle Office Space, Customer Service Manager Office, Office next to Customer Service

Manager Office, Rms 1225B, 1215, 1141, 4,870 SF

Presumed Asbestos-Containing Materials Inventory

Material

Description Location

Estimated Quantity

Photograph

GSA-

LAFA-10

Linoleum Flooring (Gray with Swirls and

Waves)

Kitchen in GSA Suite, Rm. Across from

SB82, Mail Room/ Print Shop, Kitchen throughout the Floors

2,786 SF

LAFA-11

Linoleum Flooring (Grey

Wave/Line Patterned)

Breakroom 1080 1,880 SF

LAFA-12

Grey Sink Undercoating

Kitchenette attached to 1225B, Kitchenette across from 1138

5 Each

LAFA-13

Elevator Brake Shoes

Penthouse elevator machine room

28 Each

APPENDIX C – NON-ASBESTOS-CONTAINING MATERIAL INVENTORY

Non-Asbestos-Containing Materials Identified During the 2019 Survey HA Material Description Location Sample Number Results Photograph

GSA-

LAFA-02

Sprayed-on Fire Proofing (Tan) on I-Beam

Basement by B21 mechanical room

GSA-LAFA-

02A, 02B, 02C

None Detected

LAFA-03

12"x12" Floor Tile (White with Gray Streaks)

Room 1310 / Penthouse mechanical room

GSA-LAFA-

03A, 03B, 03C

LAFA-04

Fire Stop (Red) on Pipe Penetrations

B21 Mechanical room GSA-LAFA- 04A, 04B, 04C

LAFA-05

Seam Sealant (Off-white) on Paper wraps on

Fiberglass Pipe Insulation

Mechanical Rooms – Throughout

GSA-LAFA-

05A, 05B, 05C

Non-Asbestos-Containing Materials Identified During the 2019 Survey HA Material Description Location Sample Number Results Photograph

Not assigned

Seam sealant (gray) on bare metal duct joint

Mechanical Rooms – Throughout

Determined via sampling during past surveys

Not assigned

Drywall and associated Joint Compound

Throughout the Building Determined via sampling during

Black grainy (foam) pipe insulation

1312 mech. room, Hallway by 1312, Server room across

1310, B01 storage

Determined via sampling during

Gray sprayed-on fire proofing

1st Floor Determined via sampling during

None Detected Not Available

APPENDIX D – LABORATORY ANALYTICAL RESULTS

Chain of Custody: 256733

Client: Rambin Global JV

Address: 6401 Golden Triangle Drive Greenbelt, MD 20770

Attention: Judi Darnell

Job Name: GSA-Lafayette Building

Job Location: Lafayette Building Washington, DC

Job Number: GSA-02

P.O. Number: Not Provided

Date Submitted: 11/22/2019

Date Analyzed: 11/25/2019

Report Date: 11/25/2019

Date Sampled: 11/22/2019

Person Submitting: Sameera Meegoda

CERTIFICATE OF ANALYSIS

Summary of Polarized Light Microscopy

AMA

Sample Number

Client Sample Number

Total Asbestos

Chrysotile Percent

Amosite Percent

Crocidolite Percent

Other Asbestos Percent

Mineral Wool Percent

Fiberglass Percent

Organic Percent

Synthetic Percent

Other Percent

Particulate Percent

Sample Type

Sample Color

Homogeneity Analyst

ID

Comments

256733-1 GSA-LAFA-01A 60 60 -- -- -- -- -- -- -- -- 40 DI Off- White

Homogeneous PC

256733-2 GSA-LAFA-01B -- -- -- -- -- -- -- -- -- -- -- DI Off- White

-- PC Sample not analyzed.

Positive Stop.

256733-3 GSA-LAFA-01C -- -- -- -- -- -- -- -- -- -- -- DI Off- White

-- PC Sample not analyzed.

Positive Stop.

256733-4 GSA-LAFA-02A NAD -- -- -- -- -- -- 35 -- -- 65 SPOFP Tan Homogeneous PC

256733-5 GSA-LAFA-02B NAD -- -- -- -- -- -- 30 -- -- 70 SPOFP Tan Homogeneous PC

256733-6 GSA-LAFA-02C NAD -- -- -- -- -- -- 40 -- -- 60 SPOFP Tan Homogeneous PC

256733-7 GSA-LAFA-03A NAD -- -- -- -- -- -- -- -- -- 100 FT Multi Homogeneous PC

256733-7A GSA-LAFA-03A NAD -- -- -- -- -- -- -- -- -- 100 MS Yellow Homogeneous PC

256733-8 GSA-LAFA-03B NAD -- -- -- -- -- -- -- -- -- 100 FT Multi Homogeneous PC

256733-8A GSA-LAFA-03B NAD -- -- -- -- -- -- -- -- -- 100 MS Yellow Homogeneous PC

256733-9 GSA-LAFA-03C NAD -- -- -- -- -- -- -- -- -- 100 FT Multi Homogeneous PC

256733-9A GSA-LAFA-03C NAD -- -- -- -- -- -- -- -- -- 100 MS Yellow Homogeneous PC

256733-10 GSA-LAFA-04A NAD -- -- -- -- -- 2 -- -- -- 98 FS Red Homogeneous PC

256733-11 GSA-LAFA-04B NAD -- -- -- -- -- 2 -- -- -- 98 FS Red Homogeneous PC

256733-12 GSA-LAFA-04C NAD -- -- -- -- -- 2 -- -- -- 98 FS Red Homogeneous PC

256733-13 GSA-LAFA-05A NAD -- -- -- -- 2 -- -- -- 2 96 SSL Off- White

Homogeneous PC

256733-14 GSA-LAFA-05B NAD -- -- -- -- -- -- -- -- 2 98 SSL Off- White

Homogeneous PC

4475 Forbes Blvd. · Lanham, MD, 20706 · (301) 459-2640 · Toll Free (800) 346-0961 · Fax (301) 459-2643 1/2

Chain of Custody: 256733

Client: Rambin Global JV

Address: 6401 Golden Triangle Drive Greenbelt, MD 20770

Attention: Judi Darnell

Job Name: GSA-Lafayette Building

Job Location: Lafayette Building Washington, DC

Job Number: GSA-02

P.O. Number: Not Provided

Date Submitted: 11/22/2019

Date Analyzed: 11/25/2019

Report Date: 11/25/2019

Date Sampled: 11/22/2019

Person Submitting: Sameera Meegoda

256733-15 GSA-LAFA-05C NAD -- -- -- -- -- -- -- -- 2 98 SSL Off- White

Homogeneous PC

CERTIFICATE OF ANALYSIS

Summary of Polarized Light Microscopy

AMA

Sample Number

Client Sample Number

Total Asbestos

Chrysotile Percent

Amosite Percent

Crocidolite Percent

Other Asbestos Percent

Mineral Wool Percent

Fiberglass Percent

Organic Percent

Synthetic Percent

Other Percent

Particulate Percent

Sample Type

Sample Color

Homogeneity Analyst

ID

Comments

The following footnotes only apply to those samples which the total asbestos result is flagged with a note number.

TEM RECOMMENDATION - Please note, due to resolution limitations with optical microscopy and/or interference from matrix components of this sample, results which are reported via PLM as negative or trace (<1%) for asbestos may contain a significant quantity of asbestos. It is recommended that the additional analytical technique of TEM be used to check for asbestos fibers below the resolution limits of optical microscopy.

MATRIX REDUCTION RECOMMENDATION - Please note, due to interference from the matrix components of this sample, results which are reported via PLM as negative or trace (<1%) for asbestos may contain a significant quantity of asbestos which is obscured from view. It is recommended that the additional preparation technique of gravimetric reduction be performed on this sample to minimize the obscuring effects of matrix components, followed by reanalysis by PLM and/or TEM.

Analysis Method - EPA/600/R-93/116 dated July 1993 NAD = "No Asbestos Detected" TR = "Trace equals less than 1% of this component"

Uncertainty: For samples containing asbestos in range of 1-10% the CV is 0.43, 11-35% CV=0.55, >35 CV=0.23. All results are to be considered preliminary and subject to change unless signed by the Technical Director or Deputy.

Analyst(s): Peerawut Chaikeenee

Technical Director Michael Greenberg

This report applies only to the sample, or samples, investigated and is not necessarily indicative of the quality or condition of apparently identical or similar products. As a mutual protection to clients, the public, and these Laboratories, this report is submitted and accepted for the exclusive use of the client to whom it is addressed and upon the condition that it is not to be used, in whole or in part, in any advertising or publicity matter without prior written authorization from us. Sample types, locations, and collection protocols are based upon the information provided by the persons submitting them and, unless collected by personnel of these Laboratories, we expressly disclaim any knowledge and liability for the accuracy and completeness of this information. Residual sample material will be discarded in accordance with the appropriate regulatory guidelines, unless otherwise requested by the client. NVLAP accreditation applies only to polarized light microscopy of bulk samples and transmission electron microscopy of AHERA air samples. This report must not be used to claim, and does not imply product certification, approval, or endorsement by NVLAP or any agency of the Federal Government. All rights reserved. AMA Analytical Services, Inc.

4475 Forbes Blvd. · Lanham, MD, 20706 · (301) 459-2640 · Toll Free (800) 346-0961 · Fax (301) 459-2643 2/2

By Polarized Light Microscopy EPA Method: 600/R-93/116 and 600/M4-82-020

LAB #173190

GSA AHERA Lafayette BldgProject:

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos Fibrous

Components Non-Fibrous Components

Attributes

Treatment

Stacy KahatapitiyaAttn:Customer: ARC Environmental 1311 Haubert Rd Baltimore, MD 21230

Analysis ID: 1610508_PLM

Date Reported: 5/31/2016

Date Received: 5/31/2016

Lab Order ID: 1610508

None DetectedDW1-4 Drywall Wall White Non Fibrous Homogeneous

Crushed1610508PLM_1

Cellulose Fiber Glass Other

10% 5% 85%

None DetectedDW1-5 Drywall Wall White Non Fibrous Homogeneous

Crushed1610508PLM_2

Cellulose Fiber Glass Other

10% 5% 85%

None DetectedDW1-6 Drywall Wall White Non Fibrous Homogeneous

Crushed1610508PLM_3

Cellulose Fiber Glass Other

10% 5% 85%

None DetectedJC1-7 Joint Compound Associated with DW1

White Non Fibrous Homogeneous

Crushed1610508PLM_4

Other100%

None DetectedJC1-8 Joint Compound Associated with DW1

White Non Fibrous Homogeneous

Crushed1610508PLM_5

Other100%

None DetectedJC1-9 Joint Compound Associated with DW1

White Non Fibrous Homogeneous

Crushed1610508PLM_6

Other100%

None DetectedPIM1-10 White Pipe Seam Sealant Mastic

White, Silver Fibrous Homogeneous

Dissolved1610508PLM_7

Cellulose Fiber Glass Other

40% 10% 50%

None DetectedPIM1-11 White Pipe Seam Sealant Mastic

White, Silver Fibrous Homogeneous

Dissolved1610508PLM_8

Cellulose Fiber Glass Other

40% 10% 50%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Megan Javonovich (31)

P-F-002 r15 1/15/2018

LAB #173190

GSA AHERA Lafayette BldgProject:

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos Fibrous

Components Non-Fibrous Components

Attributes

Treatment

Stacy KahatapitiyaAttn:Customer: ARC Environmental 1311 Haubert Rd Baltimore, MD 21230

Analysis ID: 1610508_PLM

Date Reported: 5/31/2016

Date Received: 5/31/2016

Lab Order ID: 1610508

None DetectedPIM1-12 White Pipe Seam Sealant Mastic

White, Silver Fibrous Homogeneous

Dissolved1610508PLM_9

Cellulose Fiber Glass Other

40% 10% 50%

None DetectedPI1-13 Black Grainy Pipe Insulation White, Black Non Fibrous Heterogeneous

Dissolved, Crushed1610508PLM_10

Cellulose Other15% 85%

None DetectedPI1-14 Black Grainy Pipe Insulation Black Non Fibrous Heterogeneous

Crushed1610508PLM_11

Other100%

None DetectedPI1-15 Black Grainy Pipe Insulation White, Black Non Fibrous Heterogeneous

Dissolved, Crushed1610508PLM_12

Cellulose Other15% 85%

None DetectedDM1-28 Grey Duct Seam Sealant on Bare Metal Duct

Gray Non Fibrous Homogeneous

Dissolved1610508PLM_13

Other100%

None DetectedDM1-29 Grey Duct Seam Sealant on Bare Metal Duct

Gray Non Fibrous Homogeneous

Dissolved1610508PLM_14

Other100%

None DetectedDM1-30 Grey Duct Seam Sealant on Bare Metal Duct

Gray Non Fibrous Homogeneous

Dissolved1610508PLM_15

Other100%

None DetectedDIM1-37 White Duct Seam Sealant on Fiberglass Duct Wrap

White, Gray Fibrous Heterogeneous

Dissolved1610508PLM_16

Mineral Wool Wollastonite Other

20% 3% 77%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

LAB #173190

GSA AHERA Lafayette BldgProject:

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos Fibrous

Components Non-Fibrous Components

Attributes

Treatment

Stacy KahatapitiyaAttn:Customer: ARC Environmental 1311 Haubert Rd Baltimore, MD 21230

Analysis ID: 1610508_PLM

Date Reported: 5/31/2016

Date Received: 5/31/2016

Lab Order ID: 1610508

None DetectedDIM1-38 White Duct Seam Sealant on Fiberglass Duct Wrap

White, Gray Fibrous Heterogeneous

Dissolved1610508PLM_17

Mineral Wool Wollastonite Other

20% 3% 77%

None DetectedDIM1-39 White Duct Seam Sealant on Fiberglass Duct Wrap

White, Gray Fibrous Heterogeneous

Dissolved1610508PLM_18

Mineral Wool Wollastonite Other

20% 3% 77%

None DetectedMD1-40 Brown Mastic Daub Brown Non Fibrous Homogeneous

Dissolved1610508PLM_19

Other100%

None DetectedMD1-41 Brown Mastic Daub Brown Non Fibrous Homogeneous

Dissolved1610508PLM_20

Other100%

None DetectedMD1-42 Brown Mastic Daub Brown Non Fibrous Homogeneous

Dissolved1610508PLM_21

Other100%

10% Chrysotile

DI2-46

Cork Duct Insulation with Black Mastic

Black Non Fibrous Homogeneous

Dissolved1610508PLM_22

Other90%

10% Chrysotile

DI2-47

Cork Duct Insulation with Black Mastic

Black Non Fibrous Homogeneous

Dissolved1610508PLM_23

Other90%

10% Chrysotile

DI2-48

Cork Duct Insulation with Black Mastic

Black Non Fibrous Homogeneous

Dissolved1610508PLM_24

Other90%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

LAB #173190

GSA AHERA Lafayette BldgProject:

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos Fibrous

Components Non-Fibrous Components

Attributes

Treatment

Stacy KahatapitiyaAttn:Customer: ARC Environmental 1311 Haubert Rd Baltimore, MD 21230

Analysis ID: 1610508_PLM

Date Reported: 5/31/2016

Date Received: 5/31/2016

Lab Order ID: 1610508

None DetectedSFP1-49 Grey Spray-on Fireproofing Gray Fibrous Heterogeneous

Teased1610508PLM_25

Cellulose Other Vermiculite20%

70% 10%

None DetectedSFP1-50 Grey Spray-on Fireproofing Gray Fibrous Heterogeneous

Teased1610508PLM_26

Cellulose Other Vermiculite20%

70% 10%

None DetectedSFP1-51 Grey Spray-on Fireproofing Gray Fibrous Heterogeneous

Teased1610508PLM_27

Cellulose Other Vermiculite20%

70% 10%

None DetectedSFP1-52 Grey Spray-on Fireproofing Gray Fibrous Heterogeneous

Teased1610508PLM_28

Cellulose Other Vermiculite20%

70% 10%

None DetectedSFP1-53 Grey Spray-on Fireproofing Gray Fibrous Heterogeneous

Teased1610508PLM_29

Cellulose Other Vermiculite20%

70% 10%

None DetectedSFP1-54 Grey Spray-on Fireproofing Gray Fibrous Heterogeneous

Teased1610508PLM_30

Cellulose Other Vermiculite20%

70% 10%

None DetectedSFP1-55 Grey Spray-on Fireproofing Gray Fibrous Heterogeneous

Teased1610508PLM_31

Cellulose Other Vermiculite20%

70% 10%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

)~)050~

• EPA 600

TumAroundTlma:I

ISiffiDIi NIIII&' LiII , OWl.. OWl OW1-l5 OWl OWl-6 OWl Je1-? JCl JC1 ·8 JCl JC1·9 JCl

P1M1-10 PIM1

PlM1·1' PIMl

PIM1-12 PIM1

PJ1-13 Pll P11-14 Pll PI1 -15 Pll OM1·28 OMl OM1·29 DMl DMl·30 OMl

OIM1 -37 [)IM1

DlMl·38 DIM1

DIM1-39 01M1

MOHO MDl MD1-41 MOl MD1-42 MOl 0124 012 012-47 012 012-48 012

SFP1-49 SFP1

SFPl-50 SFPl SFP1·51 SFPl SFP1·52 SFPl

SFP1-Q3 SFP1

u.o Co/urm "8. for ytJllcontacIlnIb

To See on Exenpe CIICI< /he _ Ex"""", Tab.

En,......",.. _ - " _ "»"

...", SampIw willi. '"c< --.. 11M _....",.

tII1d end IIIIIIII a -..>-beIow"..'uI..",..

Only E_'/OIl data"" the Iht.-"Sheet1·

Note; o.ta 1 am Data 2.,.. opIloneI 5/23/2016 fields thlll do not "'- up on /he_ ropod. __ theywfll be_ in the el9clronJc data ratumed to you

DryNan Wall [)ryNall Wall 0ry.Ya1l Wall Joint Compound Associated with OW1 Joint Compound Associated with OW1 JoInt Compound Associated with OW1 White Pipe Seam Sealant Maille White Pipe Seam Sealant ......stic White Pipe Seam Sealant Mastic Black Grainy Pipe Insulation Black Grainy Pipe InsulaUon Black GraIny Pipe Insulation Grey Duct Seam Sealant on Bate Metal Duct Grey Duct Seam Sealant on Bare "lal Duct Grey Duct Seam Sealant on Bare Metal Duct V{hlte D~ Seoam Sealant on Flberglass ~..tWf'IIIl White Duct Seam Sealant on Fiberglass Duct Wrap While OIJd Seam Sellint on Fl:MHgIass Duct Wrap Brown Mastic Daub Brown Mastic Dautl Brown MastIc. Daub Cor1I; Ducl In,ullltion wIth Blad!. Mastic Corte Ouc( Insulatlon with BIId( Mastic Cork Duct Insulation with Black Mastic Grey SP'OY-<>n Flrep_ng Grey Spray-on Fweproofing Grey SQray-on FwptOOfing Grey Spray-on Fireproor'"g Grey Spray-oo Fireproofing

•:J02-L Po_ 'fir.

GNllnd'DI'O, NC 27407 Phone: 3345.2112._ hx:

SiOi

ThroughOul the Building Throughout the Building Throughout the BuIj4;ng Ttvoughoul lhe Bullding ThroughooAl tho Building TtvoughOu1 1he Building Throughout lhe Building Throughou11ho Building Throughoul the Building Throughout the Building Throughout the Building Throughoul the Buidlng Throughout the &lfding ThroughOut the Building Throug/1o<Jllhe Bulking

T~.!'O B~3 Ttvoughou11ho BuIOlng Throughou1lhe Building 1st Floor 1st Floor 151 Floor Throughout the Building Throughou11he Buidlng Throughout the Building 1st Aoor 1st Floor 1st Floor 1st Floor 1st Floor

~cc.pted oR~

Ilolo6iJg

K{;I;1-$tdhe Environmental, Inc. u.._.......__1rIb I~e Stecy Kahatapitiya- 1311 Haubert Street ~ Baltimore:

410.659.9971 To SM..~Ctofr /tie

410.92.1065 Fa: boItom~T.

vironmentBI.<x .

likwon@arcenviro[] m8otal.com

EmoII: EnIIr..-.."-'- .... _ "».

GSA AHERA Lafayette Bldg .........,.,.....~-.......,.~ ~ ..~ 141... ...,Qllyfllllt__......___• ~'--...............,......"..

-CI.tnt_ " ~/-P.o... 3/IZ-t_Dr.-=""l1l/IDele 2..op/JDIIII__l1li "'"_ up ...... _.,..., ' " " 5123120160:00 GJ _lIbDtO, NC 27407

_ n ..zfI:1.31NJ8 ~-IIIIy"'''-.....-.:Iw*__.."'"P LM eEPA 600An.tIyIIo: Fait, 3IfS.2II2.3313

...",,.,,. '-comT-....mmo: 24 ..- "'........, OW1-4 OWl DW1-5 OWl DW1-6 OWl JC1-7 JCl JC1-8 JCl JC1-9 JCl PIM1-10 PI.Ml

PIM1-11 PIM1

PIM1-f2 PIM1 P11-13 Pll P11-14 Pl.l

PI1-15 PI1

OMl-28 OMl

DM1-29 OM1

DM1-30 OMl

DIM1-37 DIM1

DIM1-38 0l.M1

DIM1-39 DIM1

MD1-40 MOl M01-41 MOl MD1-42 MOl 012-46 012 012-47 012 012-48 01.2

SFP1-49 SFP1

SFP1-50 SFPl SFP1-51 SFPl SFP1-52 SFPl

SFP1-53 SFP1

SFP1-54 SFP1

SFP1-55 SFP1

Drywall Wall OrywallWall Drywall Wall Joint Compound Assoc;jated with OW1 Joint Compound Associated with OW1 Joint Compound Associated with OWl White Pipe Seam Sealant Mastic White Pipe Seam Sealanl Mastic White Pipe Seam Sealant Mastic Black Grainy Pipe Insulation Black. Grainy Pipe Insulation Black. Grainy Pipe Insulation Grey Duct Seam Sealant on Bare Metal Duct Grey Duct Seam Sealant on Bare Metal Duct Grey Duct Seam Sealant on Bare Metal Duct \Nhite Duct Seam Sealanl on Fiberglass Duct Wrap White Duct Seam Sealant on Fiberglass Duct Wrap 'Mlite Duct Seam Sealant on Fiberglass Duct Wrap Brown Mastic Daub Brown Mastic Daub Brown Mastic Daub Cork Duct Insulation with Black Mastic CorK Duct Insulation with Black Mastic CorK Duct Insulation with Black Mastic Grey Spray-on Fireproofing Gray Spray-on Fireproofing Grey Spray-on Fireproofing Grey Sptay-on Fireproofing Grey Spray-on Fireproofing Grey Spray-on Fireproofing Grey Spray-on Firepft:lofing

Throughout the Building Throughout the Building Throughout the Building Throughout the Bu ilding Throughout the Bu ilding Throughout the Building Throughout the Building Throughout the Building Throughout the Building Throughout the Building Throughout the Building Throughout the Building Throughout the Building Throughout the Building Throughout the Building Throughout the Building Throughout the Building Throughout the Building 1st Floor 1st Floor 1et Floor Throughout the Building Throughout the Building Throughout the Building 1st Floor 1st Floor 1st Floor 1st Floor 1st Floor 1st Floor 1st Floor

APPENDIX E – GSA INSPECTION FORMS

Asbestos Assessment Data Form

Bldg. Name: Lafayette Building Assessment Date:

11/22/2019

Address: 811 Vermont Ave. NW, Washington, D.C. 20009

GSA Bldg. No: DC0026ZZ Amounts

(SF/LF/CF):

500 SF est.

Asbestos Inspector: Sameera Meegoda

Homogeneous Sampling Area #: GSA-LAFA-01

(Assign HSA Number)

HSA Description: Duct Insulation (White - Fibrous)

Location(s) of HSA in Bldg.: Penthouse elevator machine room (Include Functional Space)

HSA Category Damage Accessibility

Surfacing Material Significant High

X Thermal Systems Insulation X Minor X Medium

Miscellaneous Material None Low

Air Plenum: Yes X No

Friability Traffic Vibration Potential for Air Erosion

X Yes High High High

No X Medium Medium Medium

Low X Low X Low

Comments:

AHERA

Classification:

1 1. Damaged or significantly damaged TSI ACBM

2. Damaged friable surfacing ACBM

3. Significantly damaged friable surfacing ACBM

4. Damaged and significantly damaged friable miscellaneous ACBM

5. ACBM with potential for damage

7. Any remaining friable ACBM or Friable suspected ACBM

Sample Number Sample Location Result

GSA-LAFA-01A Penthouse elevator machine room 60% Chrysotile

GSA-LAFA-01B Penthouse elevator machine room Not analyzed, Pos. stop

GSA-LAFA-01C Penthouse elevator machine room Not analyzed, Pos. stop

(Include percent and type of asbestos in result, e.g. 50% Chrysotile)

NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and definitions.

Date:

11/22/2019

15,177 SF est.

Asbestos Inspector: Sameera Meegoda

Homogeneous Sampling Area #: GSA-LAFA-06

(Assign HSA Number)

HSA Description: Drywall Ceiling

Location(s) of HSA in Bldg.: Throughout the Building

Thermal Systems Insulation Minor Medium

X Miscellaneous Material X None X Low

Yes High High High

X No Medium Medium Medium

X Low X Low X Low

Comments: Material is Presumed to be ACBM

5 1. Damaged or significantly damaged TSI ACBM

2. Damaged friable surfacing ACBM

3. Significantly damaged friable surfacing ACBM

4. Damaged and significantly damaged friable miscellaneous ACBM

5. ACBM with potential for damage

NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and definitions.

Date:

11/22/2019

69 Each

Asbestos Inspector: Sameera Meegoda

Homogeneous Sampling Area #: GSA-LAFA-07

(Assign HSA Number)

HSA Description: Fire Doors

Thermal Systems Insulation Minor X Medium

X Miscellaneous Material X None Low

X No X Medium Medium Medium

5 1. Damaged or significantly damaged TSI ACBM

2. Damaged friable surfacing ACBM

3. Significantly damaged friable surfacing ACBM

4. Damaged and significantly damaged friable miscellaneous ACBM

5. ACBM with potential for damage

NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and definitions.

Date:

11/22/2019

9,971 SF est.

Asbestos Inspector: Sameera Meegoda

Homogeneous Sampling Area #: GSA-LAFA-08

(Assign HSA Number)

HSA Description: 4” White Baseboard and Associated Mastic

5 1. Damaged or significantly damaged TSI ACBM

2. Damaged friable surfacing ACBM

3. Significantly damaged friable surfacing ACBM

4. Damaged and significantly damaged friable miscellaneous ACBM

5. ACBM with potential for damage

NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and definitions.

Date:

11/22/2019

4,870 SF est.

Asbestos Inspector: Sameera Meegoda

Homogeneous Sampling Area #: GSA-LAFA-09

(Assign HSA Number)

HSA Description: Yellow Carpet Mastic

Location(s) of HSA in Bldg.: USA 12 Conference Room, GSA-11, GSA Cubicle Office Space, Customer Service Manager Office, Office next to Customer Service Manager Office, Rms 1225B, 1215, 1141, 1126

5 1. Damaged or significantly damaged TSI ACBM

2. Damaged friable surfacing ACBM

3. Significantly damaged friable surfacing ACBM

4. Damaged and significantly damaged friable miscellaneous ACBM

5. ACBM with potential for damage

NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and definitions.

Date:

11/22/2019

2,786 SF est.

Asbestos Inspector: Sameera Meegoda

Homogeneous Sampling Area #: GSA-LAFA-10

(Assign HSA Number)

HSA Description: Linoleum Flooring (Gray with Swirls and Waves)

Location(s) of HSA in Bldg.: Kitchen in GSA Suite, Rm. Across from SB82, Mail Room/ Print Shop, Kitchen throughout the Floors

Surfacing Material Significant X High

5 1. Damaged or significantly damaged TSI ACBM

2. Damaged friable surfacing ACBM

3. Significantly damaged friable surfacing ACBM

4. Damaged and significantly damaged friable miscellaneous ACBM

5. ACBM with potential for damage

NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and definitions.

Date:

11/22/2019

1,880 SF est.

Asbestos Inspector: Sameera Meegoda

Homogeneous Sampling Area #: GSA-LAFA-11

(Assign HSA Number)

HSA Description: Linoleum Flooring (Grey Wave/Line Patterned)

Location(s) of HSA in Bldg.: Breakroom 1080

Surfacing Material Significant X High

5 1. Damaged or significantly damaged TSI ACBM

2. Damaged friable surfacing ACBM

3. Significantly damaged friable surfacing ACBM

4. Damaged and significantly damaged friable miscellaneous ACBM

5. ACBM with potential for damage

NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and definitions.

Date:

11/22/2019

5 Each

Asbestos Inspector: Sameera Meegoda

Homogeneous Sampling Area #: GSA-LAFA-12

(Assign HSA Number)

HSA Description: Grey Sink Undercoating

Location(s) of HSA in Bldg.: Kitchenette attached to 1225B, Kitchenette across from 1138

5 1. Damaged or significantly damaged TSI ACBM

2. Damaged friable surfacing ACBM

3. Significantly damaged friable surfacing ACBM

4. Damaged and significantly damaged friable miscellaneous ACBM

5. ACBM with potential for damage

NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and definitions.

Date:

11/22/2019

28 Each

Asbestos Inspector: Sameera Meegoda

Homogeneous Sampling Area #: GSA-LAFA-13

(Assign HSA Number)

HSA Description: Elevator Brake Shoes

Location(s) of HSA in Bldg.: Penthouse elevator machine room

Yes High X High High

X Low Low X Low

5 1. Damaged or significantly damaged TSI ACBM

2. Damaged friable surfacing ACBM

3. Significantly damaged friable surfacing ACBM

4. Damaged and significantly damaged friable miscellaneous ACBM

5. ACBM with potential for damage

NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and definitions.

APPENDIX F – INSPECTOR ACCREDITATION

Approval Number: 21 14 01

Carla M. Gomez Course Director

19-344 Location: Columbia, MD

Certificate of Achievement Awarded to

Sameera Meegoda In recognition of successful completion of the course entitled

ASBESTOS BUILDING INSPECTOR REVIEW

A 4-Hour annual review program of study presented in accordance with the provisions of the U.S

Environmental Protection Agency Model Accreditation Plan 40 CFR Part 763, Appendix C to SUBPART E, for Accreditation under TSCA Title II

Certificate Number Clayton E. Miller Course Instructor April 16, 2019

Examination Date April 16, 2019 April 16, 2020 Course Date Expiration Date

9231 Rumsey Road Columbia, Maryland 21045 410-381-0232

APPENDIX G – 2019 INVENTORY OF ACM AND PACM, MATERIAL

ASSESSMENT, AND APPROXIMATE ABATEMENT COSTS

Surveyor Date Building HA Sample Number

Location Material Description Estimated Quantity

Units Friable Condition Results Estimated

Quantity of Damage

Estimated Abatement

Costs

Recommende d Response

Action

Rambin Global

JV

11/22/2019 DC0026ZZ

GSA-LAFA-

GSA-LAFA-

01A, 01B, 01C Penthouse elevator machine room Duct Insulation (White - Fibrous) 500 SF Yes

Fair (damaged)

60% Chrysotile 2 SF $16,165.00

Enclose/Repair /Remove;

Otherwise

O&M

Surveyor Date Building HA Sample Number

Location Material Description Estimated Quantity

Units Friable Condition Results Estimated

Quantity of Damage

Estimated Abatement

Costs

Recommende d Response

Action

Rambin Global

JV

11/22/2019 DC0026ZZ

GSA-LAFA-

Presumed ACBM by

2019 Survey Throughout the Building Drywall Ceiling 15,177 SF No Good PACM N/A $74,670.84 O&M

Rambin Global

JV

11/22/2019 DC0026ZZ

GSA-LAFA-

Presumed ACBM by

2019 Survey Throughout the Building Fire Doors 69 Each No Good PACM N/A $21,210.60 O&M

Rambin Global

JV

11/22/2019 DC0026ZZ

GSA-LAFA-

Presumed ACBM by

2019 Survey Throughout the Building

4” White Baseboard and Associated Mastic

9,971 LF No Good PACM N/A $24,528.66 O&M

Rambin Global

JV

11/22/2019 DC0026ZZ

GSA-LAFA-

Presumed ACBM by

2019 Survey

USA 12 Conference Room, GSA- 11, GSA Cubicle Office Space, Customer Service Manager Office, Office next to Customer Service Manager Office, Rms 1225B, 1215, 1141, 1126

Yellow Carpet Mastic 4,870 SF No Good PACM N/A $31,216.70 O&M

Rambin Global

JV

11/22/2019 DC0026ZZ

GSA-LAFA-

Presumed ACBM by

2019 Survey

Kitchen in GSA Suite, Rm. Across from SB82, Mail Room/ Print Shop, Kitchen throughout the

Floors

Linoleum Flooring (Gray with Swirls and Waves)

2,786 SF No Good PACM N/A $17,858.26 O&M

Rambin Global

JV

11/22/2019 DC0026ZZ

GSA-LAFA-

Presumed ACBM by

2019 Survey Breakroom 1080

Linoleum Flooring (Grey Wave/Line Patterned)

1,880 SF No Good PACM N/A $12,050.80 O&M

Rambin Global

JV

11/22/2019 DC0026ZZ

GSA-LAFA-

Presumed ACBM by

2019 Survey

Kitchenette attached to 1225B, Kitchenette across from 1138

Grey Sink Undercoating 5 Each No Good PACM N/A $1,537.00 O&M

Rambin Global

JV

11/22/2019 DC0026ZZ

GSA-LAFA-

Presumed ACBM by

2019 Survey Penthouse elevator machine room Elevator Brake Shoes 28 Each No Good PACM N/A $688.52 O&M

2019 Inventory of ACM and PACM, Material Assessment, and Approximate Abatement Costs for GSA Lafayette Building (DC0026ZZ)

Asbestos-Containing Materials Inventory, Assessment, and Abatement Costs

Presumed Asbestos-Containing Materials Inventory, Assessment, and Abatement Costs

File details come from the government source that posted it. Updated .