10 H 05 Hazmat Bulk Sampling Test Report Submittal_11 1 16.pdf
PDF 349 KB Posted
- Attached to
- National Elevator Modernization & Construction IDIQ for Task Orders over $1 Million Federal contract opportunity
- Solicitation number
- 47PM1124R0011
About this file
This document contains a presolicitation notice and draft solicitation for a National Elevator Modernization Indefinite Delivery/Indefinite Quantity contract. The General Services Administration intends to award multiple IDIQ contracts for a one year base period and four one-year options to complete elevator construction and modernization task orders over $1 million in value totaling $650 million. Up to six small businesses as defined by NAICS code 238290 with a size standard of $22 million will be awarded. Interested vendors are requested to review the draft solicitation and attachments in Google folders and provide any questions, comments or recommendations by April 11, 2024. The agency will issue two initial task order solicitations concurrently and proposals will be due approximately 30 days after final RFP release.
View the file
Other files for this federal contract opportunity
Show all 50
National Elevator Modernization & Construction IDIQ for Task Orders over $1 Million has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Detailed, Grouped by Each Number
Weaver Building Project # G16.0337 Grunley Construction Company, Inc.
451 7 th St NW
Washington DC 20410
Tel: 240-399-2000 Fax: 240-399-2020
Transmitted To: Brian Gifford Transmitted By: Austin Reynaud
GSA Grunley Construction Company, Inc.
301 7th St SW Rm 224 Washington DC 20407
15020 Shady Grove Road Suite 500 Rockville, MD 20850
Tel: 240.399.2000 Fax: 240.399.2001
Qty Submittal Package No Description Due Date Package Action
1 0001 – 02 2200 - 0 Bulk Sampling Test Reports Submitted for Approval
Approval E-mail
Items Qty Description Notes Item Action
1 Bulk Sampling Test Reports Submitted for Approval
Remarks
Signature Signed Date
Date: 8/31/2016
Transmitted For Delivered Via Tracking Number
Cc: Company Name Contact Name Copies Notes
Submittal Transmittal
Review Stamp
X Approved for Construction
Approved as Noted for Construction
Deviation from Contract Requirements
Revise and Resubmit
Date: 10/30/2016
Reviewer: Austin Reynaud
Spec Section(s): 02 2000
Submittal No.: 02 2200-001-0
Item Submitted:
Product Data Bulk Sampling Test Reports
Reviewer's Comments:
GSA Review Comments
Please find attached Submittal 02 2200-001-0 Bulk Sampling Test Reports
GRUNLEY CONSTRUCTION CO., INC.
SUBMITTAL RECOMMENDATION
G16.037 Weaver Building Fire Alarm Replacement
PN# GS11P16MKKC7120 PC# VDC00145
Approval subject to contract requirements
Project Manager
9231 Rumsey Road Columbia, Maryland 21045
Telephone 410-381-0232 Fax 410-381-8908
September 30, 2016
Mr. Austin Reynaud Project Manager Grunley Construction Company, Inc.
15020 Shady Grove Road, Suite 500 Rockville, Maryland 20850
Subject: Limited Asbestos Containing Material
Robert C. Weaver Federal Building 451 7th Street SW Washington, DC 20022 ATC Project Number: 10186.0386 Phase 1
Dear Mr. Reynaud:
ATC Group Services, LLC was retained by Grunley Construction Company, Inc. (“Client”) to perform a limited Asbestos-Containing Material (ACM) inspection to determine if suspect asbestos-containing building materials will be disturbed during the undergoing renovation activities at the above-referenced location (“Site”). ATC was requested to collect drywall and associated joint compound samples from elevator lobby ceilings. It should be noted that the ceilings within the elevator lobbies had been reported to ATC as plaster, however, upon arrival and inspection, ATC determined that the elevator lobby ceilings were drywall with joint compound. No plaster ceilings were observed in the elevator lobbies.
Limited Asbestos-Containing Material Screening
Mr. David Thompson a U.S. Environmental Protection Agency (EPA) asbestos inspector performed the limited ACM inspection on September 22, 2016. ATC's inspector performed both the visual inspection and bulk sampling at the site in accordance with methods outlined in the U.S. EPA guidance document titled, "Guidance for Controlling Asbestos-Containing Materials in Buildings" (Document No. 560/5- 85/024). A total of eleven (11) bulk samples of suspect ACM were collected from previously identified location at the above-referenced. Bulk samples of suspect materials were collected and taken for analysis to EMSL Analytical, Inc. of Beltsville, Maryland using the approved transmission electron microscopy (TEM) ELAP 198.4, with dispersion staining method. Only the asbestos content, if any, is recorded in the bulk sample ‘Report of Analysis’.
EMSL is an accredited laboratory by the EPA for "Interim Asbestos Bulk Sample Analysis Quality Assurance Program". EMSL is also accredited by the National Voluntary Laboratory Accreditation Program (NVLAP). The TEM method ELAP 198.4 was used to confirm the percentage of asbestos in those samples. Table I below includes the sample number, material description, sample location and analytical result of the bulk sample analyzed via TEM.
TABLE I – BULK SAMPLING RESULTS contains a listing of all suspect ACM sampled by ATC from the Site located at 451 7th Street SW, Washington, DC. This table includes the sample number, material description, sample location and analytical result of each bulk sample. All samples were collected from elevator lobbies.
Table I – Bulk Sample Results
Sample Number Material Description Sample Location Analytical Result
September 28, 2016 DT – 01 Drywall/Joint Compound
Composite 10th Floor Ceiling NAD
DT – 02 Drywall/Joint Compound
Composite 10th Floor Ceiling NAD
DT – 03 Drywall/Joint Compound Composite
10th Floor Ceiling NAD
DT – 04 Drywall/Joint Compound Composite
10th Floor Ceiling NAD
DT – 05 Drywall/Joint Compound Composite
10th Floor Ceiling NAD
DT – 06 Drywall/Joint Compound Composite
10th Floor Ceiling NAD
DT – 07 Drywall/Joint Compound Composite
8th Floor Ceiling NAD
DT – 08 Drywall/Joint Compound Composite
8th Floor Ceiling NAD
DT – 09 Drywall/Joint Compound Composite
8th Floor Ceiling NAD
DT – 10 Drywall/Joint Compound Composite
1st Floor Ceiling NAD
DT – 11 Drywall/Joint Compound Composite
1st Floor Ceiling NAD
NAD = No Asbestos Detected
TABLE I above contains a listing of all material that was sampled by ATC and found that samples contained < 1% asbestos via TEM as indicated. These samples were analyzed via TEM (ELAP 198.4) to verify asbestos content.
The U.S. Environmental Protection Agency (U.S. EPA) in appendix E, subpart E, 40 CFR part 763, section 1 states that if the asbestos content is less than 10 percent as determined by a method other than point counting by PLM, then the asbestos content can be verified by using TEM. The TEM method was used to confirm the percentage of asbestos in those samples in Table I above.
Enclosed, please find a copy of the laboratory analysis report for the bulk samples.
Conclusions and Recommendations
All other suspect asbestos containing materials uncovered during the renovation activities not identified within this report should be assumed to be asbestos-containing, unless future bulk sampling determines otherwise.
Please note that this assessment was limited only to these surfaces and materials identified herein and that other potential asbestos-containing materials may remain on-site. If you have any questions, please contact our office in Columbia, Maryland at (410) 381-0232. Our facsimile number is (410) 381-8908.
Sincerely, ATC
David Thompson Dennis Raver Industrial Hygienist ATC – Columbia, MD
Attachments
Division Manager, Building Sciences ATC -Columbia, MD
Attachments
Laboratory Analysis Results (Bulk Samples)
EMSL Analytical, Inc.
10768 Baltimore Avenue Beltsville, MD 20705
Tel/Fax: (301) 937-5700 / (301) 937-5701 http://www.EMSL.com / beltsvillelab@emsl.com
EMSL Order: 191611403
Customer ID: ATCE52
Customer PO:
Project ID:
Attention: Alyssa Mrvos Phone: (504) 344-1957
ATC Group Services LLC Fax: (410) 381-8908
9231 Rumsey Road Received Date: 09/23/2016 10:30 AM
Columbia, MD 21045-1924 Analysis Date: 09/28/2016
Collected Date: 09/23/2016
10186-0386Project:
Test Report: Asbestos Analysis of Non-Friable Organically Bound Materials by TEM via
EPA/600/R-93/116 Section 2.5.5.1
Sample ID Description Appearance % Matrix Material % Non-Asbestos Fibers Asbestos Types
DT-01
191611403-0001
DRYWALL, JOINT CMPD
& COMPOSITE
Brown/White
Fibrous
Heterogeneous
100 None No Asbestos Detected
DT-02
191611403-0002
DRYWALL, JOINT CMPD
& COMPOSITE
Brown/White
Fibrous
Heterogeneous
100 None No Asbestos Detected
DT-03
191611403-0003
DRYWALL, JOINT CMPD
& COMPOSITE
Brown/White
Fibrous
Heterogeneous
100 None No Asbestos Detected
DT-04
191611403-0004
DRYWALL, JOINT CMPD
& COMPOSITE
Brown/White
Fibrous
Heterogeneous
100 None No Asbestos Detected
DT-05
191611403-0005
DRYWALL, JOINT CMPD
& COMPOSITE
Brown/White
Fibrous
Heterogeneous
100 None No Asbestos Detected
DT-06
191611403-0006
DRYWALL, JOINT CMPD
& COMPOSITE
Brown/White
Fibrous
Heterogeneous
100 None No Asbestos Detected
DT-07
191611403-0007
DRYWALL, JOINT CMPD
& COMPOSITE
Brown/White
Fibrous
Heterogeneous
100 None No Asbestos Detected
DT-08
191611403-0008
DRYWALL, JOINT CMPD
& COMPOSITE
Brown/White
Fibrous
Heterogeneous
100 None No Asbestos Detected
DT-09
191611403-0009
DRYWALL, JOINT CMPD
& COMPOSITE
Brown/White
Fibrous
Heterogeneous
100 None No Asbestos Detected
DT-10
191611403-0010
DRYWALL, JOINT CMPD
& COMPOSITE
Brown/White
Fibrous
Heterogeneous
100 None No Asbestos Detected
DT-11
191611403-0011
DRYWALL, JOINT CMPD
& COMPOSITE
Brown/White
Fibrous
Heterogeneous
100 None No Asbestos Detected
This laboratory is not responsible for % asbestos in total sample when the residue only is submitted for analysis. The above report relates only to the items tested. This report may not be reproduced, except in full, without written approval by EMSL Analytical , Inc. Samples received in good condition unless otherwise noted. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.
Samples analyzed by EMSL Analytical, Inc. Beltsville, MD
Initial report from: 09/28/2016 14:24:50
ASB_PLMEPANOB_0012 Printed 9/28/2016 2:26:02PM Page 1 of 2
EMSL Analytical, Inc.
10768 Baltimore Avenue Beltsville, MD 20705
Tel/Fax: (301) 937-5700 / (301) 937-5701 http://www.EMSL.com / beltsvillelab@emsl.com
EMSL Order: 191611403
Customer ID: ATCE52
Customer PO:
Project ID:
Attention: Alyssa Mrvos Phone: (504) 344-1957
ATC Group Services LLC Fax: (410) 381-8908
9231 Rumsey Road Received Date: 09/23/2016 10:30 AM
Columbia, MD 21045-1924 Analysis Date: 09/28/2016
Collected Date: 09/23/2016
10186-0386Project:
Test Report: Asbestos Analysis of Non-Friable Organically Bound Materials by TEM via
EPA/600/R-93/116 Section 2.5.5.1
Sample ID Description Appearance % Matrix Material % Non-Asbestos Fibers Asbestos Types
Analyst(s)
Emily Baker (11) Joe Centifonti, Laboratory Manager or other approved signatory
This laboratory is not responsible for % asbestos in total sample when the residue only is submitted for analysis. The above report relates only to the items tested. This report may not be reproduced, except in full, without written approval by EMSL Analytical , Inc. Samples received in good condition unless otherwise noted. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.
Samples analyzed by EMSL Analytical, Inc. Beltsville, MD
Initial report from: 09/28/2016 14:24:50
ASB_PLMEPANOB_0012 Printed 9/28/2016 2:26:02PM Page 2 of 2
OrderID: 191611403
Weaver Building– Taken September 22, 2016 451 7th Street, SW Washington, DC
Picture #1 – Main lobby ceiling.
Picture #2 – Elevator lobby ceiling.
Picture #3 – Elevator lobby drywall ceiling.
Picture #4 – Close up of drywall elevator lobby ceiling.
| Bulk Sampling Test ReportsTransmittal |
| Bulk Sampling Stamp |
| 02200 001-0 Weaver Building Asbestos TEM Report |
| Attachments |
| Laboratory Analysis Results |
| (Bulk Samples) |
File details come from the government source that posted it. Updated .