The Military Sealift Command is seeking shaft seal inspection services for the USNS MATTHEW PERRY, located at Naval Base Guam's Tango Pier. The solicitation (RFQ N4044625Q0006) requires a comprehensive inspection of the ship's shaft seal closed loop system, including external piping, fittings, pipe hangers, and welds from the shaft alley Frame 85 to the stern tube. Contractors must conduct a pre-dive planning meeting with key stakeholders and submit detailed electronic inspection reports with photographs. The government will award a firm-fixed-price purchase order to the lowest-priced technically acceptable quoter, with quotes due by 11:00 PM EST on February 20, 2025. Technical submissions must address all pre-award requirements defined in the statement of work, and vendors must complete specific Department of the Navy access documentation at least four days before site visits.
The solicitation is set aside exclusively for small businesses under NAICS code 811310, with a size standard of $12.5M for Commercial and Industrial Machinery and Equipment Repair and Maintenance. The work is scheduled for performance on February 22-24, 2025, with a specific focus on inspecting the ship's critical shaft seal systems in preparation for an upcoming sea trial. Contractors must comply with specific safety requirements, including navigating high-voltage electrical systems with non-standard color coding. The place of performance is Naval Base Guam, specifically the Tango Pier location. While no specific contract value is explicitly stated, the procurement will be executed through a single firm-fixed-price purchase order, with vendors required to submit quotes via email to MGU-SSN10@fe.navy.mil in Adobe or Microsoft Office format.
N4044625Q0006 Department of the Navy Military Sealift Command
Solicitation 1/1
2/20/25, 12:40 AM 400Hz Frequency Converter Maintenance
PRE-SOLICITATION NOTICE
The Army Contracting Command, Aberdeen Proving Ground, Tobyhanna Division, Tobyhanna, PA 18466, intends to solicit and award a firm fixed-price supply contract for Preventative Maintenance and Emergency On call service repairs for thirty seven (37) 400 Hz cycle converters located throughout Tobyhanna Army Depot. The NAICS Code is 811310 and the size standard is $8M. A Request for Proposal will be issued on or about March 9, 2020 under Solicitation number W25G1V-20-R-0017 as a %100 small business set aside. This notice of intent is not a request for competitive proposals.
Solicitation will be in accordance with FAR Part 12, Acquisition of Commercial Items and FAR Part 13.5, "Simplified Procedures for Certain Commercial Items" and therefore will utilize simplified procedures for soliciting competition, evaluation, award documentation and notification that comply with FAR 13.1.
The following draft Performance Work Statement (PWS) may be updated, revised or changed throughout the Solicitation period. The Government is not responsible for any costs incurred for contractor's time or materials expended in preparing information/response to this Pre-Solicitation Notice and any subsequent Solicitation.
Key elements of the “PWS” shall include, but not be limited to the following:
1) Preventative Maintenance and Emergency On call service repairs for thirty seven (37) 400 Hz cycle converters located throughout Tobyhanna Army Depot. The Preventative Maintenance requirements are at three various TIER levels, and each TIER is described below. Also included within this contract will be up to Six (6) Emergency On Call Repair Services. The converters are from various manufacturers, a table will be provided in the Solicitation PWS which identifies the specific converters to be serviced.
2) General Requirements:
Contractor shall supply all supervision, labor and test equipment, tools, travel and lodging to provide preventative maintenance service to appropriate TIER level as per table located in PWS. Up to Six emergency on call repairs is included in the contract as well.
3) Specifications:
a. TIER I Preventative Maintenance: Preventative Maintenance (PM) shall identify any problems and making necessary adjustments and/or repairs in accordance with manufacturers specifications including but not limited to the following for each individual converter:
1. Inspect for proper operation and potential problems
2. Correct any potential problems.
3. Disconnect all input power and lock out panel.
4. Open all panel doors and remove all covers to visually inspect for loose connections, deterioration and charring. Items to be inspected shall include but not be limited to all power connections, power cables, capacitors, transformers and associated components, semi-conductors, wire harnesses, printed circuit boards, cooling fans, blowers, circuit breakers and power supplies. Repair and replace as needed.
5. Check/verify all the input and output voltages/wattages and ensure that all meters and indicator lights are operating properly. If voltages are out of tolerance or meters or lights are not working properly, the appropriate corrective action will be taken.
6. Clean all filters, replace as needed. Vacuum inside of converter. This includes total cleaning of the unit.
7. Contractor will provide a written report to the Contracting Officer Representative (COR) on all findings and recommendations.
8. PM shall be scheduled through the COR one month prior to the PM taking place.
9. PM will be performed on a quarterly basis (every 3 months) and will consist of four visits per year on all aforementioned converters.
b. TIER II Preventative Maintenance: PM shall identify any problems and making necessary adjustments and/or repairs in accordance with manufacturers specifications including but not limited to the following for each individual converter:
1. Inspect for proper operation and potential problems
2. Correct any potential problems.
3. Disconnect all input power and lock out panel.
4. Open all panel doors and remove all covers to visually inspect for loose connections, deterioration and charring. Items to be inspected shall include but not be limited to all power connections, power cables, capacitors, transformers and associated components, semi-conductors, wire harnesses, printed circuit boards, cooling fans, blowers, circuit breakers and power supplies. Repair and replace as needed.
5. Check/verify all the input and output voltages/wattages and ensure that all meters and indicator lights are operating properly. If voltages are out of tolerance or meters or lights are not working properly, the appropriate corrective action will be taken.
6. Clean all filters, replace as needed. Vacuum inside of converter. This includes total cleaning of the unit.
7. Contractor will provide a written report to the COR on all findings and recommendations.
8. PM shall be scheduled through the COR one month prior to the PM taking place.
9. PM will be performed on a semi-annual basis (every 6 months) and will consist of two visits per year on all aforementioned power supplies.
c. TIER III Preventative Maintenance
1. PM will be performed on an annual (once yearly) basis and will consist of one visit per year on units that are idle, in storage or utilized as temporary units. If and when the units are pulled out of storage to replace one of the units in TIER I or TIER II, that unit would then become a TIER I or TIER II unit and PM for that TIER would be followed for the remainder of the contract.
2. Contractor will be responsible to visually inspect housekeeping and check the unit to be in working order.
4) Place of Performance:
Contractor will perform all services on-site at Tobyhanna Army Depot, 11 Hap Arnold Blvd, Tobyhanna, PA 18466. Repairs and PMs are to be performed during normal duty hours, Monday through Friday, 0730 to 1500 hours, excluding holidays and Base closure days. The only exception to this would be any emergency repairs required when units are inoperable and required to meet mission requirements.
5) Parts and Repairs:
a. Contractor will provide all parts, tools, equipment, travel, lodging and labor to successfully complete any repairs that are required. Upon completion of all repairs and PMs, the Contractor will demonstrate to appropriate personnel that all converters are fully operational under “load” conditions.
b. Contractor will provide a list of parts with the associated cost, if any. The COR (or appropriate personnel) will verify parts/work required. Contractor shall not commence any work without prior authorization.
c. The contractor will provide a written report describing all repairs made including a list of parts replaced.
6) Evaluation of Upgrade:
a. Preventative Maintenance Services will include evaluation of all the units for possible upgrade. Contractor is to discuss and provide a report on any engineering changes or installations that would be necessary, along with associated costs to convert units from the current configurations.
7) Emergency Calls:
a. Contractor will provide a qualified factory trained technician to perform all repairs for on-site emergency service calls (up to 6 total Emergency calls throughout the course of the contract). Response time for any and all emergency service calls on all units will be within a 48 hour timeframe, not to exceed 72 hour response time will be mandatory. An emergency call shall be defined as follows: any problem that threatens to cause any converter to become inoperable. The Contractor will provide a list of all parts needed to return any aforementioned converter to its operational condition “under load”. Once approved the Contractor will install all parts to return any aforementioned converter to its operational condition.
8) Payment:
a. Payment will be on a quarterly basis, after certification by COR. All invoices will be submitted and paid through WAWF.
9) Quality Assurance:
a. Quality Assurance/Rejection of work: Any indication of lack of quality workmanship on the part of the contractor shall be sufficient grounds for TYAD to reject the work until the contractor performs the required repairs to conform to the contract. There will be no additional costs incurred to TYAD for these services.
This notice of intent is not a request for competitive proposals. A determination by the Government not to compete this requirement based on this notice is solely within the discretion of the Government.
All information contained within this Pre-Solicitation Notification is subject to change.