Y1NB--PN: 438-22-900, Replace Boiler Plant (SF) 36C26324R0136

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
36C26324R0136
Agency
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

Place of performance
Sioux Falls, South Dakota 57105, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 23 is seeking a contractor to replace the boiler plant at the Sioux Falls VA Medical Center. The solicitation (36C26324R0136) is for a comprehensive boiler plant replacement project involving construction of a new facility, removal of existing infrastructure, and installation of new mechanical, electrical, and plumbing systems. The proposal evaluation will use a best-value tradeoff approach considering six factors: Technical Approach, Experience, Key Personnel Experience, Past Performance, Submitted Boiler Specifications, and Price, with non-price factors being significantly more important than price. Technical questions were due by January 3, 2025, and proposals are due on February 27, 2025, with an anticipated award date of May 27, 2025. Contractors must attend a mandatory pre-proposal site visit and adhere to detailed technical specifications across multiple engineering disciplines.

The solicitation is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) with a size standard of $45 million under NAICS code 236220. The project is estimated to be valued between $20-50 million and will have a performance period of 915 calendar days from the Notice to Proceed. The place of performance is the VA Medical Center located at 2501 W 22nd St in Sioux Falls, South Dakota. The project involves constructing an 8,121 square foot boiler plant building with associated equipment, including three new boilers, underground fuel and water storage tanks, steam tunnel extensions, and comprehensive utility infrastructure modifications. Contractors will need to coordinate closely with VA operations to minimize disruption, with night and weekend work likely required to maintain facility continuity during construction.

Notice text

438-22-900, Replace Boiler Plant

Files

File Type Posted
Electrical - Addendum 4 Final Version.pdf PDF
Structural Merged - Addendum 4.pdf PDF
260533 - Raceways and Boxes for Electrical System - Addendum 4.pdf PDF
AE121 - Addendum 4.pdf PDF
Civil Merged - Addendum 4.pdf PDF
438-22-900 Replace Boiler Plant QA 2 02-12-25.docx DOCX document
102600 Wall and Door Protection - Addendum 4.pdf PDF
36C26324R0136 0006.docx DOCX document
ES101 - ELECTRICAL - SITE PLAN.pdf PDF
SB302.pdf PDF
GI001.pdf PDF
SF401.pdf PDF
FA501 - FRE ALARM DETAILS.pdf PDF
CU101 5 - CIVIL UTILITY PLAN.pdf PDF
EP102 - ENLARGED ELECTRICAL ROOM PLANS.pdf PDF
EP101 - ELECTRICAL POWER PLAN FIRST FLOOR.pdf PDF
CG104 5 - CIVIL EROSION CONTROL PLAN.pdf PDF
336300 STEAM ENERGY DISTRIBUTION.pdf PDF
EM101 - MOTOR AND EQUIPMENT PLAN FIRST FLOOR.pdf PDF
CG102 - CIVIL GRADING PLAN.pdf PDF
FA502 - FIRE ALARM DETAILS.pdf PDF
SF102.pdf PDF
102800 Toilet Bath and Laundry Accessories.pdf PDF
EP501 - NORMAL POWER ONE-LINE DIAGRAM.pdf PDF
SF402.pdf PDF
SF104.pdf PDF
CG101 - CIVIL GRADING PLAN.pdf PDF
SF103.pdf PDF
ET502 - TELECOMMUNICATIONS DETAILS.pdf PDF
CG103 5-CIVIL EROSION CONTROL PLAN.pdf PDF
PL700-WATER FLOW DIAGRAM.pdf PDF
232111 BOILER PLANT PIPING SYSTEMS_Addendum_3.pdf PDF
CD101 5 - CIVIL EXISTING CONDITIONS_ DEMOLITION PLAN.pdf PDF
MQ100 - MECHANICAL EQUIPMENT PLAN.pdf PDF
262911 Motor Controllers.pdf PDF
PL600-PLUMBING SCHEDULES.pdf PDF
CU102 5 - CIVIL UTILITY PLAN.pdf PDF
123600 Countertops.pdf PDF
EP503 - NORMAL POWER ONE-LINE DIAGRAM.pdf PDF
CJ301 13 OF 17 - CIVIL UTILITY PROFILE.pdf PDF
014500 Quality Control.pdf PDF
PL101-PLUMBING PLANS.pdf PDF
AE121.pdf PDF
123200 Manufactured Wood Casework.pdf PDF
ES105 - NEW TUNNEL PLAN.pdf PDF
280528.33 Conduits and Backboxes for Electronic Safety and Security.pdf PDF
096723.30 RESINOUS EPOXY BASE FLOORING.pdf PDF
EL103 - ELECTRICAL LIGHTING PLAN PARKING LOT.pdf PDF
ET101 - TELECOMMUNICATIONS PLAN FIRST FLOOR.pdf PDF
014535 Special Inspections - Statement of SI.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

Notice history

Notice Type Posted
Y1NB--PN: 438-22-900, Replace Boiler Plant (SF) 36C26324R0136 Award Award Notice
This notice Latest solicitation Solicitation
Y1DA--PN: 438-22-900, Replace Boiler Plant (SF) 36C26324R0136 Pre-Solicitation
Y1DA--PN: 438-22-900, Replace Boiler Plant (SF) 36C26324R0136 Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
PN: 438-21-403, Renovate First Floor Kitchen (SF) Sioux Falls, South Dakota 57105, United States · NAICS 236220 Veterans Integrated Service Network 23 Service-Disabled Veteran-Owned Small Business
Z1DA--Project 695-24-107 Replace Boilers 4 and 5 Clement J. Zablocki, VA Medical Center 5000 West National Avenue Milwaukee, WI 53295 United States · NAICS 238220 Veterans Integrated Service Network 12 Service-Disabled Veteran-Owned Small Business
Z1DA--550-20-121 Demo Old Boiler Plant B100 (CON) Veterans Affairs Illiana Healthcare System -Vaihcs Danville, Illinois 61832, United States · NAICS 236220 Veterans Integrated Service Network 12 Service-Disabled Veteran-Owned Small Business
Z1DA--FY27 NRM - Replace B98 and B88 Boiler and Sump Pumps Department of Veterans Affairs Va Northern California Health Care System McClellan Park CA 95652, United States · NAICS 236220 Veterans Integrated Service Network 21 No set-aside
Y1DZ--replace chilled water pump at the boiler plant Department of Veterans Affairs Network Contracting Office 2 Bronx, New York 10468, United States · NAICS 236220 Veterans Integrated Service Network 2 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors