SF104.pdf

Standard Form PDF 772 KB Posted

Attached to
Y1NB--PN: 438-22-900, Replace Boiler Plant (SF) 36C26324R0136
Solicitation number
36C26324R0136
Issued by

About this file

This is an architectural/engineering drawing showing roof supplemental framing and reinforcing details for a boiler plant replacement project at a VA facility. The drawing contains two plan views - one showing structural framing layout and another showing reinforcement details. The drawing includes specific dimensions, grid lines, and technical notations typical of construction documents. It was prepared by Paradigm Engineering as part of project number 438-22-900 for the U.S. Department of Veterans Affairs Office of Construction and Facilities Management.

The drawing contains general notes regarding construction specifications and a tie schedule in the top right corner. The plans appear to be fully finalized construction documents, indicated by professional stamps and approvals. This drawing is part of a larger set of construction documents for the boiler plant replacement project, focusing specifically on structural modifications required for the roof system.

View the file

Who attaches SF 104

Other files

File Type Posted
Structural Merged - Addendum 4.pdf PDF
Electrical - Addendum 4 Final Version.pdf PDF
438-22-900 Replace Boiler Plant QA 2 02-12-25.docx DOCX document
260533 - Raceways and Boxes for Electrical System - Addendum 4.pdf PDF
Civil Merged - Addendum 4.pdf PDF
AE121 - Addendum 4.pdf PDF
36C26324R0136 0006.docx DOCX document
102600 Wall and Door Protection - Addendum 4.pdf PDF
EP602 - PANEL SCHEDULES.pdf PDF
MQ100 - MECHANICAL EQUIPMENT PLAN.pdf PDF
EP101 - ELECTRICAL POWER PLAN FIRST FLOOR.pdf PDF
017419 Construction Waste Management.pdf PDF
CU101 5 - CIVIL UTILITY PLAN.pdf PDF
GI001.pdf PDF
AE600.pdf PDF
014535 Special Inspections - Schedule of SI.pdf PDF
085653 Blast Resistant Windows.pdf PDF
SB302.pdf PDF
SE201.pdf PDF
122400 Window Shades.pdf PDF
PL700-WATER FLOW DIAGRAM.pdf PDF
GI110.pdf PDF
230923 DIRECT-DIGITAL CONTROL SYSTEM FOR HVAC Addendum 3.pdf PDF
SB101.pdf PDF
263213 Engine Generators.pdf PDF
232111 BOILER PLANT PIPING SYSTEMS_Addendum_3.pdf PDF
CK502 - CIVIL DETAILS.pdf PDF
E502 - ELECTRICAL DETAILS.pdf PDF
CS102 5-CIVIL SITE PLAN.pdf PDF
CK503 - CIVIL DETAILS.pdf PDF
EP603 - PANEL SCHEDULES.pdf PDF
EP604 - PANEL SCHEDULES.pdf PDF
312011 - Earthwork.pdf PDF
EP102 - ENLARGED ELECTRICAL ROOM PLANS.pdf PDF
PL101-PLUMBING PLANS.pdf PDF
CG103 5-CIVIL EROSION CONTROL PLAN.pdf PDF
019100 General Commissioning Requirements.pdf PDF
PL300-PLUMBING SECTIONS.pdf PDF
PL701-PLUMBING WATER RISER DIAGRAM.pdf PDF
ES105 - NEW TUNNEL PLAN.pdf PDF
336300 STEAM ENERGY DISTRIBUTION.pdf PDF
270511 Requirements for Communications Installations.pdf PDF
SF401.pdf PDF
271500 Communications Structured Cabling.pdf PDF
087100 Door Hardware.pdf PDF
MP500 - PIPING DETAILS.pdf PDF
AE121.pdf PDF
CD102 5 - CIVIL EXISTING CONDITIONS_ DEMOLITION PLAN.pdf PDF
262600 Power Distribution Units for Static Uninteruptable Power Systems.pdf PDF
ES106 - ELECTRICAL - SECURITY GATE PLAN.pdf PDF
Show 40 more

Latest 50 of 134 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TRUE

N

PLAN

N

TRUE

N

PLAN

N

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Architecture Engineering Design-Build paradigm

AutoCAD SHX Text A

AutoCAD SHX Text A.1

AutoCAD SHX Text

AutoCAD SHX Text 1.1

AutoCAD SHX Text C

AutoCAD SHX Text B.3

AutoCAD SHX Text 77'-5 "58"

AutoCAD SHX Text

AutoCAD SHX Text 1.1

AutoCAD SHX Text 25'-8"

AutoCAD SHX Text 25'-8"

AutoCAD SHX Text 24'-1 "58"

AutoCAD SHX Text 80'-8 "78"

AutoCAD SHX Text B

AutoCAD SHX Text B.2

AutoCAD SHX Text 100'-11 "2932"

AutoCAD SHX Text

AutoCAD SHX Text 5.1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 5.1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 97'-8 "2132"

AutoCAD SHX Text 32'-0"

AutoCAD SHX Text 33'-0"

AutoCAD SHX Text 30'-8 "2132"

AutoCAD SHX Text A

AutoCAD SHX Text A.1

AutoCAD SHX Text C

AutoCAD SHX Text B.3

AutoCAD SHX Text B

AutoCAD SHX Text B.2

AutoCAD SHX Text A

AutoCAD SHX Text A.1

AutoCAD SHX Text

AutoCAD SHX Text 1.1

AutoCAD SHX Text C

AutoCAD SHX Text B.3

AutoCAD SHX Text 77'-5 "58"

AutoCAD SHX Text

AutoCAD SHX Text 1.1

AutoCAD SHX Text 25'-8"

AutoCAD SHX Text 25'-8"

AutoCAD SHX Text 24'-1 "58"

AutoCAD SHX Text 80'-8 "78"

AutoCAD SHX Text B

AutoCAD SHX Text B.2

AutoCAD SHX Text 100'-11 "2932"

AutoCAD SHX Text

AutoCAD SHX Text 5.1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 5.1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 97'-8 "2132"

AutoCAD SHX Text 32'-0"

AutoCAD SHX Text 33'-0"

AutoCAD SHX Text 30'-8 "2132"

AutoCAD SHX Text A

AutoCAD SHX Text A.1

AutoCAD SHX Text C

AutoCAD SHX Text B.3

AutoCAD SHX Text B

AutoCAD SHX Text B.2

AutoCAD SHX Text

TIE TYPE

AutoCAD SHX Text

TIE SIZE

AutoCAD SHX Text

SPACING

AutoCAD SHX Text

(3)-#5 CONT.

AutoCAD SHX Text N/A

AutoCAD SHX Text

PERIMETER "P1"

AutoCAD SHX Text

X-DIRECTION

AutoCAD SHX Text

TIE SCHEDULE

AutoCAD SHX Text

NOTES

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text

Y-DIRECTION

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text

(5)-#5 CONT.

AutoCAD SHX Text N/A

AutoCAD SHX Text

PERIMETER "P2"

AutoCAD SHX Text

AutoCAD SHX Text NOTES: 1. CONTRACTOR OPTION: (4) #6 CONT. BARSCONTRACTOR OPTION: (4) #6 CONT. BARS

AutoCAD SHX Text F5

AutoCAD SHX Text 1/8" = 1'-0"

AutoCAD SHX Text

ROOF SLAB REINFORCING PLAN

AutoCAD SHX Text F1

AutoCAD SHX Text 1/8" = 1'-0"

AutoCAD SHX Text

ROOF FRAMING PLAN - SUPPLEMTAL SUPPORT FRAMING - CATWALKS

AutoCAD SHX Text

TYP

AutoCAD SHX Text

TYP

AutoCAD SHX Text

TYP

AutoCAD SHX Text

TYP

AutoCAD SHX Text

TYP

AutoCAD SHX Text

TYP

AutoCAD SHX Text

ROOF SUPPLEMENTAL FRAMING AND SLAB REINFORCING DIAGRAM

AutoCAD SHX Text

SF104

AutoCAD SHX Text 200 Envoy Circle, Suite 201, Louisville KY 40299 - www.paradigmusa.com

AutoCAD SHX Text

FULLY SPRINKLERED

AutoCAD SHX Text

DESIGN REPLACE BOILER PLANT

AutoCAD SHX Text 438-22-900

AutoCAD SHX Text

AutoCAD SHX Text

SIOUX FALLS VAMC

AutoCAD SHX Text

SIOUX FALLS, SD 57105

AutoCAD SHX Text

TWW

AutoCAD SHX Text

DRW

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

AutoCAD SHX Text 08-09-2024

AutoCAD SHX Text

1808 DEEP CREEK RD. OKC, OK 73131 918.527.7166 INFO@MOONTREELLC.COM

AutoCAD SHX Text

ADDENDUM 1

AutoCAD SHX Text

AutoCAD SHX Text 08-09-24

AutoCAD SHX Text

ADDENDUM 2 (NO STRUCTURAL CHANGES)

AutoCAD SHX Text

AutoCAD SHX Text

XX-XX-XX

AutoCAD SHX Text

ADDENDUM 3

AutoCAD SHX Text

AutoCAD SHX Text 01-17-25

AutoCAD SHX Text GENERAL NOTES A. TIE-FORCE REQUIREMENTS ARE AS OUTLINED IN UFC 4-023-03 SECTION 3-1. REFER TO TIE-FORCE REQUIREMENTS ARE AS OUTLINED IN UFC 4-023-03 SECTION 3-1. REFER TO THIS REFERENCE FOR MORE INFORMATION ON THE ITEMS SHOWN THIS PLAN. B. SEE SHEET SF102 FOR FRAMING AND DIMENSIONS AND OTHER INFORMATION NOT SHOWN SEE SHEET SF102 FOR FRAMING AND DIMENSIONS AND OTHER INFORMATION NOT SHOWN THIS PLAN. FOR CLARITY. THIS PLAN SHOWS ONLY THE SLAB EDGE PERIMETER, BEAM AND COLUMN FRAMING AND TIE-FORCE SLAB REINFORCING. ADDITIONAL REINFORCING REQUIREMENTS ARE AS NOTED BELOW. C. SPLICES IN STEEL REINFORCEMENT USED FOR INTERNAL LONGITUDINAL AND TRANSVERSE SPLICES IN STEEL REINFORCEMENT USED FOR INTERNAL LONGITUDINAL AND TRANSVERSE TIES ARE NOT SHOWN ON THIS PLAN AND ARE THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE. SPLICES SHALL BE CLASS B LAP SPLICES, WELDED OR MECHANICALLY JOINED WITH TYPE I OR II MECHANICAL SPLICES PER ACI 318. TYPE II MECHANICAL SPLICES MAY BE USED AT ANY LOCATION WITHIN THE SLAB. TYPE I MECHANICAL SPLICES, WELDED SPLICES AND CLASS B LAP SPLICES SHALL BE LOCATED NO CLOSER THAN 20% OF THE BAY SPACING IN THE DIRECTION OF THE TIE TO ANY COLUMN/BAY GRID LINES. D. SPLICES IN STEEL REINFORCEMENT USED FOR PERIPHERAL TIES ARE NOT SHOWN ON THIS SPLICES IN STEEL REINFORCEMENT USED FOR PERIPHERAL TIES ARE NOT SHOWN ON THIS PLAN AND ARE THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE. FOR PERIPHERAL TIES, TYPE I MECHANICAL SPLICES, WELDED SPLICES AND CLASS B LAP SPLICES SHALL BE LOCATED NO CLOSER THAN 20% OF THE BAY SPACING TO THE COLUMN GRID LINES. E. NON-CONTACT SPLICES ARE NOT ALLOWED. NON-CONTACT SPLICES ARE NOT ALLOWED. F. USE SEISMIC HOOKS, SAME SIZE AS INTERNAL TIES, PER ACI 318 TO LAP WITH ENDS OF USE SEISMIC HOOKS, SAME SIZE AS INTERNAL TIES, PER ACI 318 TO LAP WITH ENDS OF INTERNAL TIES, USING ACI CHAPTER 12 LAP LENGTHS (SEE LAP SCHEDULE ON SHEET SG005), TO ANCHOR INTERNAL TIES TO PERIPHERAL CONTINUOUS TIE AT PERIMETER OF SLAB. ANCHORS SHALL ENCOMPASS OUTER LINE OF PERIPHERAL REINFORCEMENT IF MORE THAN ONE BAR IS USED FOR PERIPHERAL TIE LINE.

AutoCAD SHX Text KEY NOTES 1. CONTINUOUS PERIMETER/PERIPHERAL TIE BARS, TYP. REFER TO SCHEDULE. REFER TO CONTINUOUS PERIMETER/PERIPHERAL TIE BARS, TYP. REFER TO SCHEDULE. REFER TO SHEET NOTE D FOR SPLICE INFORMATION. 2. BEAM/GIRDER FRAMING, TYP. REFER TO SHEET SF102. ADJUST CONTINUOUS INTERNAL TIE BEAM/GIRDER FRAMING, TYP. REFER TO SHEET SF102. ADJUST CONTINUOUS INTERNAL TIE ADJUST CONTINUOUS INTERNAL TIE SPACING SUCH THAT INTERNAL TIES DO NOT FALL DIRECTLY ABOVE FLOOR FRAMING MEMBERS, TYP. 3. "X-DIRECTION" CONTINUOUS INTERNAL TIE REINFORCING, TYP. REFER TO SCHEDULE. "X-DIRECTION" CONTINUOUS INTERNAL TIE REINFORCING, TYP. REFER TO SCHEDULE. 4. "Y-DIRECTION" CONTINUOUS INTERNAL TIE REINFORCING, TYP. REFER TO SCHEDULE. "Y-DIRECTION" CONTINUOUS INTERNAL TIE REINFORCING, TYP. REFER TO SCHEDULE. 5. SEISMIC HOOK PER ACI 318, SAME SIZE AND SPACING AS INTERNAL TIE REINFORCING. SEISMIC HOOK PER ACI 318, SAME SIZE AND SPACING AS INTERNAL TIE REINFORCING. PROVIDE SPLICE WITH TIE REINFORCING, TYP. REFER TO SHEET NOTE C. 6. AT CORNERS PENETRATIONS LARGER THAN 12"x12", PROVIDE SLAB REINFORCING AT CORNERS PENETRATIONS LARGER THAN 12"x12", PROVIDE SLAB REINFORCING CONFIGURED PER DETAIL C9/SF402 AND EXTEND BARS INTO SLAB FIELD PER LAP LENGTH ON SHEET SG005. 7. AT COLUMN LINES PROVIDE BARS BETWEEN COLUMNS SAME SIZE AND SPACING AS AT COLUMN LINES PROVIDE BARS BETWEEN COLUMNS SAME SIZE AND SPACING AS INTERNAL TIE REINFORCING BUT DO NOT SPLICE OR LAP WITHIN THE COLUMN STRIP, NOT SPECIFICALLY SHOWN ON PLAN AT ALL LOCATIONS FOR CLARITY, BUT TYPICAL ALL COLUMN/BEAM AND COLUMN/GIRDER LINES. DISCONTINUOUS REINFORCING DOES NOT NEED TO BE SHIFTED TO AVOID BEING PLACED DIRECTLY OVER MEMBERS, HOWEVER MINOR OFFSET IS REQUIRED TO AVOID CONFLICT WITH COMPOSITE BEAM SHEAR STUDS. 8. PROVIDE CORNERS BARS SAME SIZE AND NUMBER AS PERIPHERAL TIE BARS WITH ACI LAP PROVIDE CORNERS BARS SAME SIZE AND NUMBER AS PERIPHERAL TIE BARS WITH ACI LAP EACH LEG. 9. PERIPHERAL TIES SHALL BE LOCATED WITHIN 3'-3" OF EDGE OF SLAB, ALL EDGES OF PERIPHERAL TIES SHALL BE LOCATED WITHIN 3'-3" OF EDGE OF SLAB, ALL EDGES OF BUILDING. 10. L4x4x1/4 HANGERS, SEE SF103 MEZZANINE PLAN FOR DIMENSIONAL COORDINATION. FINAL L4x4x1/4 HANGERS, SEE SF103 MEZZANINE PLAN FOR DIMENSIONAL COORDINATION. FINAL MEZZANINE LAYOUT SHALL BE COORDINATED WITH FINAL EQUIPMENT SELECTION AND POSITIONING, ALL DIMENSIONS ARE APPROXIMATE AND SUBJECT TO CHANGE. 11. HORIZONTAL SUPPORT ANGLE WELDED TO BOTTOM OF MAIN ROOF FRAMING, SEE B4/SF401 HORIZONTAL SUPPORT ANGLE WELDED TO BOTTOM OF MAIN ROOF FRAMING, SEE B4/SF401 FOR INFORMATION. INSTALL CONTINUOUS ANGLES WHERE ALIGNED AS SHOWN. FINAL MEZZANINE LAYOUT SHALL BE COORDINATED WITH FINAL EQUIPMENT SELECTION AND POSITIONING, ALL DIMENSIONS ARE APPROXIMATE AND SUBJECT TO CHANGE. 12. SEE F5/SF103 FOR STEAM PIPING AND SUPPORT SUPPLEMENT FRAMING LAYOUT SEE F5/SF103 FOR STEAM PIPING AND SUPPORT SUPPLEMENT FRAMING LAYOUT INFORMATION. 13. SEE F1/SF103 FOR MAIN ROOF FRAMING INFORMATION.SEE F1/SF103 FOR MAIN ROOF FRAMING INFORMATION.

AutoCAD SHX Text

AutoCAD SHX Text

Sheets and Views
SF104

File details come from the government source that posted it. Updated .