Amendment_04_-_FY14_Backflow_Inventory_List_H-200_and_Clinics_-_2MAR2016.xls

XLS spreadsheet 54 KB Posted

Attached to
Operation and Maintenance Services at the Camp Pendleton Hospital and Outlying Medical Clinics
Solicitation number
W912PL-16-R-0011
Issued by

About this file

Amendment 04 - FY14 Backflow Inventory List H-200 and Clinics - 2MAR2016

View the file

Other files

File Type Posted
Correct_Amendment_06_-_NHCP_PWS_-_18MAR2016-2.docx DOCX document
Am7_W912PL-16-R-0011.pdf PDF
Amendment_06_-_Updated_-_Service_Contract_Wage_Rates_-_17MAR2016.pdf PDF
Amendment_06_-_NHCP_Fuel_Storage_Tanks_-_FIO.pdf PDF
Amendment_06_-_Revised_Section_M_-_17MAR2016.pdf PDF
Amendment_06_-_Updated_-_Davis-Bacon_Wage_Rates_-_17MAR2016.pdf PDF
Amendment_06_-_NHCP_PWS_-_17MAR2016.pdf PDF
Amendment_06_-_Exhaust_hoods-PM_only-_FIO.pdf PDF
Amendment_06_-_FuelFilteringSystem_-_FIO.pdf PDF
Amendment_06_-_W912PL-16-R-0011_-17MAR2016_.pdf PDF
Amendment_05_-_Revised_Section_L_-_3MAR2016.pdf PDF
Amendment_05_-_W912PL-16-R-0011_-_3MAR2016_.pdf PDF
Amendment_04_-_NURSE_CALL_SYSTEMS_-_2MAR2016.pdf PDF
Amendment_04_-_Section_M_-_2MAR2016.pdf PDF
Amendment_04_-_H-200_EXTERIOR_ELEVATIONS_-_2MAR2016.pdf PDF
Amendment_04_-_Landscaping_areas_-_2MAR2016.pdf PDF
Amendment_04_-_Amalgam_Separator_-_2MAR2016.pdf PDF
Amendment_04_-_11_24_00_00_95_BUILDING_MAINTENANCE_EQUIPMENT-_2MAR2016.pdf PDF
Amendment_04_-_W912PL-16-R-0011_-_2MAR2016_.pdf PDF
Amendment_04_-_Property_Record_Information_-_2MAR2016.xlsx XLSX spreadsheet
Amendment_03_-_PART_XIII_ConstructionSpecifications_Complete_-_23FEB2016.pdf PDF
Contractor_Sign_in_Sheet_20FEB2016.pdf PDF
Amendment_03_-_Government_Furnished_Equipment_-_23FEB2016.pdf PDF
Amendment_03_-_Floor_Plan_14_Area_Trailer_-_23FEB2016.pdf PDF
Amendment_03_-_Med_Gas_Test_Report_-_23FEB2016.pdf PDF
Amendment_03_-_Appendix_A_-_Mechanical_Equipment_Inventory_-_25FEB2016_.xlsx XLSX spreadsheet
Amendment_03_-_Revised_Section_L.pdf PDF
Amendment_03_-_Revised_Section_B.pdf PDF
Amendment_03_-_Work_Request_Summary_Report_Jan_2014_-_Dec_2015.xls XLS spreadsheet
Amendment_03_-_NHCP_PWS_-_25FEB2016.pdf PDF
Amendment_03_-_PM_Frequency_-_23FEB2016.xlsx XLSX spreadsheet
Amendment_03_-_Galley_Refrigerators_and_Freezers_-_23FEB2016.pdf PDF
Amendment_03_-_TJC_Inspections_-_23FEB2016.pdf PDF
Amendment_03_-_Hospital_Clinic_List_-_23FEB2016.xlsx XLSX spreadsheet
Amendment_03_-_H200_Tree_Inv_-_23FEB2016.pdf PDF
Amendment_03_-_FMD_Construction_Package_-__23FEB2016.pdf PDF
Amendment_03_-_Revised_Section_C.pdf PDF
Amendment_03_-_NHCP_Active_RPIE_-_23FEB2016.xlsx XLSX spreadsheet
Amendment_03_-_W912PL-16-R-0011_-_25FEB2016_.pdf PDF
Amendment_03_-_Revised_Section_M.pdf PDF
Amendment_02_-_W912PL-16-R-0011-_23FEB2016.pdf PDF
W912PL-16-R-0011-_Am01_.pdf PDF
Attachment_7_-_DB_Wage_Determinations_20JAN2016.pdf PDF
Attachment_8_-_SCA_Wage_Determinations_19JAN2016.pdf PDF
A.01.30_-_Attachment_2_-_Facility_Overview_-_21JAN2016.pdf PDF
A.01.30_-_Appendix_C_-_Personnel_Resume_Form_-_26JAN2016.docx DOCX document
A.01.30_-_Attachment_4_-_13th_Edition_Glossary_-_21JAN2016.pdf PDF
A.01.30_-_Attachment_6_-_RSMEANS_San_Diego_Cost_Index_-_21JAN2016_.pdf PDF
Solicitation_-_W912PL-16-R-0011_-_27JAN2016.pdf PDF
A.01.30_-_Attachment_1_-_Map_NHCP_and_CLINICS_-_21JAN2016.pdf PDF
Show 40 more

Latest 50 of 55 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FY14 CLINIC INVENTORY

Device AddressAcct NumberSizeMfgModelSerial Number
Bldg. 1312813128-0134Wilkins975XL1153431
Bldg. 1312813128-02100Wilkins975XL2251679
Bldg. 1312813128-03200Febco825YAH006747
Bldg. 1312813128-04200Febco825YAH007106
Bldg. 1312813128-06400Wilkins350DAN03778
Bldg. 1312813128-0734Wilkins950XL1305834
Bldg. 1312813128-08200Febco825YAH03827
Bldg. 1312813128-09200Febco825YAH03888
Bldg. 1312913129-0134Watts909399799
Bldg. 1312913129-04212Wilkins375L69877
Bldg. 1312913129-05212Wilkins375L69306
Bldg. 210735210735-0134Wilkins3752722784
Bldg. 210735210735-02200Watts800111159
Bldg. 210735210735-0434Watts909HW29178
Bldg. 210735210735-06400Wilkins375DA449
Bldg. 210735210735-0734Wilkins975XL1293570
Bldg. 210735210735-08200Wilkins975XL1938111
Bldg. 210735210735-09200Wilkins975XL1938114
Bldg. 210735210735-10200Wilkins975XL23535143
Bldg. 210735210735-11200Wilkins975XL23406476
Bldg. 2219022190-0234Wilkins975XL801886
Bldg. 2219022190-0334Wilkins975XL1190493
Bldg. 2219022190-0634Watts009M3140942
Bldg. 2219022190-07200Wilkins975XL3338341
Bldg. 2219022190-08200Wilkins975XL3338294
Bldg. 310514310514-01200Febco825YA143062
Bldg. 310514310514-03600Wilkins950DAD03614
Bldg. 310514310514-0434Wilkins950XL571534
Bldg. 310514310514-05200Wilkins975XL23501117
Bldg. 310514310514-06200Wilkins975XL23501129
Bldg. 310515310515-0234Watts009M3165250
Bldg. 310515310515-03600Watts774DCDA105833
Bldg. 310515310515-0434Watts007M158377
Bldg. 310515310515-05200Wilkins975XL23577464
Bldg. 310515310515-06200Watts975XL23561517
Bldg. 330305330305-01400Watts909DA3599
Bldg. 330305330305-0234Watts909501942
Bldg. 330305330305-03600Watts709DA133755-1
Bldg. 330305330305-0412Watts721597
Bldg. 330305330305-05112Febco825YA191078
Bldg. 330305330305-06100Watts009M2101879
Bldg. 3330533305-01200Watts909M1262092
Bldg. 414006414006-02600Watts909256249
Bldg. 414006414006-03114Febco825YH00834
Bldg. 414006414006-0434Watts009M3112175
Bldg. 414006414006-0534Watts909652425
Bldg. 414006414006-06300Wilkins375L73110
Bldg. 414006414006-07300Wilkins375L73105
Bldg. 434057434057-01400Watts909202689
Bldg. 434057434057-02600Watts909256335
Bldg. 434057434057-03112Febco825YH04590
Bldg. 434057434057-0634Watts009M3111436
Bldg. 434057434057-0734Watts909652242
Bldg. 520448520448-01112Watts800112247
Bldg. 520448520448-0234Watts009M323927
Bldg. 520448520448-0312Wilkins975XL1185744
Bldg. 520448520448-0412Wilkins975XLW297394
Bldg. 520448520448-06400Wilkins350DAN03955
Bldg. 520448520448-0734Wilkins975XLV1308713
Bldg. 520448520448-08200Wilkins975XL3228741
Bldg. 520448520448-09200Wilkins975XL3183025
Bldg. 520450520450-01100FebcoLF825YJ001250-1
Bldg. 520450520450-0412Wilkins975XLW298740
Bldg. 520450520450-05212Watts909124872
Bldg. 520450520450-06212Watts909124867
Bldg. 520450520450-0734Wilkins3752690711
Bldg. 533020533020-02200Febco825YH08127
Bldg. 533020533020-03600Watts909256029
Bldg. 533020533020-0434Watts009M3121212
Bldg. 533020533020-05300Wilkins375L69085
Bldg. 533020533020-06300Wilkins375L69080
Bldg. 533020533020-0734Watts909652422
Bldg. 620305620305-03112Febco825YA235085
Bldg. 620305620305-04600Watts709DA133682
Bldg. 620305620305-0512Watts7A02384
Bldg. 620305620305-06100Febco825YBG7678
Bldg. 620305620305-07300Wilkins375L71863
Bldg. 620305620305-08300Wilkins375L71861

H-200 INVENTORY by device size

H-200 BACKFLOW DEVICES
Device AddressLocationAcct NumberSizeMfgModelSerial Number
H-200On kitchen wall which backs up to the galley soda machine - R of 20.50WATTSLF00911203
H-200Galley - Under Soda Machine - R of 20.50WATTSLF00921460
H-200Galley - Under Coffee Maker0.50WATTSLF00911045
H-200On kitchen wall which backs up to the galley soda machine - L of 20.50WATTSLF00909396
H-200Galley - Under Juice Machine0.50WATTSLF00911550
H-200Galley - Under Soda Machine - L of 20.50WATTSLF00921501
H-200LV1 Dining Hall Galley Steamer0.50WATTSLF007QTO2379
H-200LV1 Dining Hall Galley Steam Table0.50WATTSLF007QTO2295
9TOTAL 1/2" BACKFLOW DEVICES
H-200LV3 East Room 3447 Trash Room0.75WATTSLF009M3O8705
H-200LV3 East Room 3461 Specimen Holding0.75WATTS009M3356597
H-200LV3 East Room 3461 Specimen Holding0.75WATTS009M3390040
H-200LV1 Dining Hall Galley Room 1553 Housekeeping0.75WATTSLF009M3QTO8663
H-200LV3 East Room 3473 Sub Sterile OR 1-20.75WATTS009M3QT390066
H-200LV3 East Room 3475A Sub Sterile OR 3-40.75WATTS009M3QT390146
H-200LV3 East Room 3464 Sub Sterile OR 9-100.75WATTS009M3346239
H-200LV3 East Room 3458A Sub Sterile OR 11-120.75WATTS009M3356515
H-200LV1 West Room 1248 Housekeeping 1G220.75WATTSLF003M3QTO8740
H-200LV1 East Dental Air/Vac Room 1419A0.75WATTS009M3356577
H-200LV2 East Room 2518 Housekeeping0.75WATTS009M3356513
H-200LV2 East Room 2535 Housekeeping0.75WATTSLF009M3O8643
H-200LV3 East Room 3490 Housekeeping0.75WATTSLF009M3O8664
H-200LV3 East Room 3490 Housekeeping0.75WATTS009M3390071
H-200LV2 East Room 3519 Housekeeping0.75WATTSLF009M3QTO8676
15TOTAL 3/4" BACKFLOW DEVICES
H-200LV4 East Room 4420 Housekeeping 4N181.00WATTSLF009M2OO7809
H-200LV3 East Room 3473 Sub Sterile OR 1-21.00WATTS009M2QT383787
H-200LV3 East Room 3475A Sub Sterile OR 3-41.00WATTS009M2QT392445
H-200LV East Room 3469 Sub Sterile OR 51.00WATTSLF009M2QTOO7811
H-200LV3 East Room 3464 Sub Sterile OR 9-101.00WATTSLF0009M3OO7816
H-200LV3 East Room 3458A Sub Sterile OR 11-121.00WATTS009M2391767
H-200SE PH Steam Clean South Wall1.00WATTS009M2QT391766
H-200LV1 East Bio Medical ENG Room 14041.00WATTS009M2391777
H-200LV1 East Bio Medical ENG Room 14041.00WATTS009M2383766
H-200LV2 East Room 2499B Cart Wash1.00WATTS009M2392627
10TOTAL 1" BACKFLOW DEVICES
H-200LV4 East Room 4420 Housekeeping 4N181.25WATTS009M2QT52426
H-200LV1 Dining Hall Kitchen Galley Water Filtration1.25WATTS009M2QT52442
H-200LV3 East Room 3490 Housekeeping1.25WATTSLF009M2QTO1624
3TOTAL 1 1/4" BACKFLOW DEVICES
H-200At Meter East Ring Rd; SE Corner of East PK. Garage1.50WATTSLF009M2QTOO2245
H-200At meter West Ring Rd; North Lot# 2 SW Corner1.50FEBCO825YJ015647
H-200LV1 East Room 15821.50WATTS009M2163073
3TOTAL 1 1/2" BACKFLOW DEVICES
H-200At Meter Southern Ring Rd & East Ring Rd2.00WATTSLF009M2QTOO3763
H-200LV1 Water Pump Room 16382.00WATTS009M2QT327914
H-200LV2 East Room 2499B Cart Wash2.00WATTS009M2321197
H-26Chiller Room 1092.00WATTSLF009M2OO5786
H-26Boiler Room 101 Water Softner2.00WATTSLF009M2OO3284
H-26Boiler Room 101 Water Softner2.00WATTSLF909OOO596
6TOTAL 2" BACKFLOW DEVICES
H-200LV2 East Room 2501 Sterilizer Room2.50WATTSLF009OO492
1TOTAL 2 1/2" BACKFLOW DEVICES
H-200Water Storage Tank East Ring Rd3.00AMESCOLT 400NB-0988
H-200Water Storage Tank East Ring Rd3.00AMESCOLT 400MK1930
H-200Cooling Tower Pad3.00WATTSLF009OO525
3TOTAL 3" BACKFLOW DEVICES
H-200Water Pump Room 1294.00WATTSLF90916120
H-200Water Pump Room 1294.00WATTSLF90916093
2TOTAL 4" BACKFLOW DEVICES
H-200Service Yard East Ring Rd8.00WATTS95711-0534
1TOTAL 8" BACKFLOW DEVICE
53Total Backflow Devices

COLD WTR DEVICES

DEVICE ADDRESSSIZEMFGMODELSERIAL #LOCATIONISSUE
H-2000.75WATTSLF009M3O8705LV3 East Room 3447 Trash Room
H-2000.75WATTS009M3390040LV3 East Room 3461 Specimen Holding
H-2000.75WATTSLF009M3QTO8663LV1 Dining Hall Galley Room 1553 Housekeeping
H-2000.75WATTS009M3QT390066LV3 East Room 3473 Sub Sterile OR 1-2
H-2000.75WATTS009M3QT390146LV3 East Room 3475A Sub Sterile OR 3-4
H-2000.75WATTS009M3346239LV3 East Room 3464 Sub Sterile OR 9-10
H-2000.75WATTS009M3356515LV3 East Room 3458A Sub Sterile OR 11-12
H-2000.75WATTSLF003M3QTO8740LV1 West Room 1248 Housekeeping 1G22Labeled "COLD" but flowing hot
H-2000.75WATTS009M3390071LV3 East Room 3490 Housekeeping
H-2001.00WATTSLF009M2OO7809LV4 East Room 4420 Housekeeping 4N18
H-2001.00WATTS009M2383766LV1 East Bio Medical ENG Room 1404
H-2001.00WATTS009M2391777LV1 East Bio Medical ENG Room 1404
H-2001.00WATTS009M2392627LV2 East Room 2499B Cart Wash
H-2002.00WATTS009M2321197LV2 East Room 2499B Cart Wash