APPENDIX A HVAC NEW Hosptial
APPENDIX A - H-200 (NEW HOSPITAL)
| SYSTEM | ITEM | TAG* | Manufacture Name | Manufacture Serial # | Model # | Other Location | *NOTE: Taken from E-mail 3/27/13 from FMD |
| CUP | |||||||
| Steam System | ST-SYS | ||||||
| Steam Boiler | B-1 | Cleaver-Brooks | 4WI -200-300--150ST | Boiler Room | |||
| Steam Boiler | B-2 | Cleaver-Brooks | 4WI -200-300--150ST | Boiler Room | |||
| Steam Boiler | B-3 | Cleaver-Brooks | 4WI -200-300--150ST | Boiler Room | |||
| Piping | ST-P | ||||||
| Condensate Return Pump | CP-1 Steam | Shipco | 502.5 DS | ||||
| Condensate Return Pump | CP-5 Steam | Shipco | DS |
| Heating Hot Water System | HHW-SYS | ||||
| Heating Hot Water Pump | HWP-1 | Aurora | 344A/360A | CUP | |
| Heating Hot Water Pump | HWP-2 | Aurora | 344A/360A | CUP | |
| Heat Recovery Chiller Heating Hot Water Pump | HWP-3 | Aurora | 344A/360A | CUP | |
| Heat Exchanger | HX-1 | Armstrong | WS-1604-200-4 | Boiler | |
| Heat Exchanger | HX-2 | Armstrong | WS-1604-200-4 | Boiler | |
| Heat Exchanger | HX-3 | Bell & Gossett | S19-1G10-66-TMTL89-Liquid | Chiller Rm |
| Chilled Water System | CHW-SYS | ||||
| Chiller | CH-1 | York | YKKCK SH-9CYG | Chiller Room | |
| Chiller | CH-2 | York | YKKCK SH-9CYG | Chiller Room | |
| Chiller | CH-3 | York | YKKCK SH-9CYG | Chiller Room | |
| Heat Recovery Chiller | HRCH-1 | Clima Cool | UCH071AF | ||
| Chilled Water Pump | CWP-1 | Aurora | 344A (5X6X12) | CUP | |
| Chilled Water Pump | CWP-2 | Aurora | 344A (5X6X12) | CUP | |
| Chilled Water Pump | CWP-3 | Aurora | 344A (5X6X12) | CUP | |
| Heat Recovery Chiller Pump | CWP-4 | Aurora | 344A (2.5X3X9) | CUP | |
| Refrigerant Leak Detection System | RLD-1 | Honeywell | VA301EM | Chiller room | |
| Expansion Tank | ET-1 | American Wheatley | WFA 2500 | Chiller room | |
| Expansion Tank | ET-2 | American Wheatley | WFA 2000 | Boiler Room | |
| Air Separator | AS-1 | American Wheatley | TAS008 | Chiller room | |
| Air Separator | AS-2 | American Wheatley | TAS008 | Boiler Room | |
| Tower Sand Filter Package | TSF-1 | Puroflex | SCE-20H-1608LP | Colling tower Yard |
| Condenser Water System | CD-SYS | ||||
| Cooling Tower | CT-1,2 | Marley | NC8409VAN1 | Cooling tower | |
| Cooling Tower | CT-3 | Marley | NC8409VAN3 | Cooling tower | |
| Condensate Pump | CTP-1 | Aurora | 411 (8x10x18) | CUP | |
| Condensate Pump | CTP-2 | Aurora | 411 (8x10x18) | CUP | |
| Condensate Pump | CTP-3 | Aurora | 411 (8x10x18) | CUP | |
| Condenser Return Unit | CP-1 | Bell & Gossett | 120CB75-25 | Boiler Room | |
| Condenser Return Unit | CP-5 | Bell & Gossett | 120CBE90-40 | Tunnel | |
| Condenser Water Filtration | CD-WF | Eversoft | CAR-120-F29 | CUP |
| Air Handling System | AHU-SYS | ||||
| Air Handling Unit | AHU-12 | Trane | CSO010 | CUP Roof | |
| Air Handling Unit | AHU-13 | Trane | CSO080 | CUP Roof | |
| Fan Coil Unit | FCU-1 | Trane | BCXC Blower Coil Air Handler BCHC072E2 | CUP 72 | |
| Fan Coil Unit | FCU-2 | Trane | BCXC Blower Coil Air Handler BCHC072E2 | CUP 72 | |
| Fan Coil Unit | FCU-3 | Trane | BCXC Blower Coil Air Handler BCHC072E2 | CUP 72 | |
| Fan Coil Unit | FCU-4 | Trane | BCXC Blower Coil Air Handler BCHC036E2 | CUP 36 | |
| Fan Coil Unit | FCU-5 | Trane | BCXC Blower Coil Air Handler BCHC072E2 | CUP 72 | |
| Fan Coil Unit | FCU-6 | Trane | BCXC Blower Coil Air Handler BCHC036E2 | CUP 24 | |
| Fan Coil Unit | FCU-7 | Trane | BCXC Blower Coil Air Handler BCHC036E2 | CUP 24 | |
| Fan Coil Unit | FCU-8 | Trane | BCXC Blower Coil Air Handler BCHC036E2 | CUP 24 | |
| Spilt DX A/C Outdoor Unit | CU-1P | Mitsubishi | PUY-A24NHA3 | FC-1P | |
| Spilt DX A/C Outdoor Unit | CU-2P | Mitsubishi | PUY-A42NHA3 | FC-1P | |
| Spilt DX A/C Indoor Unit | FC-1P | Mitsubishi | PEAD-A24AA | Water pump room 120 | |
| Spilt DX A/C Indoor Unit | FC-2P | Mitsubishi | PEAD-A42AA | Fire pump room 128 | |
| VFDs | TBD |
| Exhaust System | EXH-SYS-CUP | ||||
| Exhaust Fan | EF-8 | Cook | 120ACEB | CUP roof | |
| Exhaust Fan | EF-20 | Cook | 445HLC-B | CUP roof | |
| Exhaust Fan | EF-21 | Cook | 210HLC-B | CUP Chiller Room | |
| Exhaust Fan | EF-22 | Cook | 210HLC-B | CUP Chiller Room | |
| Exhaust Fan | EF-42 | Cook | 100HLC-B | Carpentry shop 123 | |
| Ductwork | DUCT-EXH-CUP |
| Plumbing System | |||||
| Water Softener | WS-1 | Eversoft | |||
| Water Heater | DWH-3 | AO Smith | BT 80 | ||
| Emergency Drain Pump | EP-1 | Weil Aquastrong | FL103M | ||
| Air Compressor | AC-1 | Atlas corps | LS5-175 80V 200/3/60/STD | ||
| Reverse Osmosis | RO-2, ROT-2 ROP-2 | Marlo | MRO-18-4H | Design Tank K6685 | |
| Fuel Oil Pump | FOP-1A&B | FE Petro | STP150-VL2 | ||
| Fuel Oil System | FOP-1A&B | Pomeco | 571EVR L 16 40 42 | Multiple assembly | |
| Fuel Oil System | FOP-2A&B | Pomeco | 571EVR L 16 40 42 | Multiple assembly | |
| Domestic Water Pump | DBP-1 | Tigerflow | TVM-30GL-RI(2)-S6-VM-P-VFD | ||
| Domestic Water Pump | CP-3 | Aurora | 1070-303.25, 1/2HP | ||
| Emergency Drain Pump | EP-1 | Weil Aquastrong | FL103M |
| SYSTEM | ITEM | TAG | Manufacture Name | Manufacture Serial # | Model # | Other Location |
| Hosptial | ||||||
| Steam System | ||||||
| Clean Steam Generator | CG-1 | Howard's Engineering | HSGV 204 16 4 24 2 Pass | |||
| Clean Steam Generator | CG-2 | Howard's Engineering | HSGV 204 16 4 24 2 Pass | |||
| Stream Trap | ST-1 | Armstrong | 125A3/125A5 | Tunnel Steam pipe drip legs | ||
| Heat Exchanger | HX-4 | Bell & Gossett | P20-DW |
| Air Handling System | AHU-SYS-HOSP | |||
| Air Handler - (AHU1) VAV-96 | AHU-1 | ENERGY LABS INC | C13136-FC-L | |
| 4101-4196 | ||||
| Air Handler | AHU-2 | ENERGY LABS INC | C13117-FC-L | |
| Air Handler | AHU-3A | ENERGY LABS INC | C78105-FCH-L | |
| Air Handler | AHU-3B | ENERGY LABS INC | C78105-FCH-L | |
| Air Handler - (AHU3) VAV-28 | AHU-3C | ENERGY LABS INC | C78105-FCH-L | |
| 3301-3328 | ||||
| Air Handler - (AHU4) VAV-17 | AHU-4 | ENERGY LABS INC | C11617-FC-L | |
| 1401-1417 | ||||
| Air Handler - (AHU5) VAV-112 | AHU-5 | ENERGY LABS INC | C128210-FC-L | |
| 1501-1522, 1524-1541, 2501-2572 | ||||
| Air Handler - (AHU6) VAV-88 | AHU-6 | ENERGY LABS INC | C131168-FC-L | |
| 1601-1682, 1684-1689 | ||||
| Air Handler - (AHU7) VAV-74 | AHU-7 | ENERGY LABS INC | C1161901FC1L | |
| 3701-3774 | ||||
| Air Handler - (AHU8) VAV-27 | AHU-8 | ENERGY LABS INC | C102148-FC-L | |
| 3801-3827 | ||||
| Air Handler - (AHU9) VAV-141 | AHU-9 | ENERGY LABS INC | C131240-FC-L | |
| 1901-1904, 1906-1919, 2901-2946, 1921-1946, 3901-3950, 4901-4919, 4921-4924, 4926-4929, 1948 | ||||
| Air Handler - (AHU10) VAV-169 | AHU-10 | ENERGY LABS INC | C131240-FC-L | |
| 11001-11038, 21001-21048, 31001-31041, 41001-41042 | ||||
| Air Handler - (AHU11) VAV-97 | AHU-11 | ENERGY LABS INC | C131267-FC-L | |
| 21101-21197 | ||||
| Air Handler | AHU-14 | Trane | CSOA004 | |
| Air Handler | AHU-15 | Trane | CSOA008 | |
| Air Handler | AHU-16 | Trane | CSOA004 | |
| Make-up Air Unit | MUA-1 | ENERGY LABS INC | 67764-MUA-1 | |
| VFDs | Multipule | ABB | Variety |
| Chilled Water System | |||||
| Chilled Water Pump | CWP-5 | Aurora | PVM8 20STG 1-1/2hp | ||
| Chilled Water Pump | CWP-6 | Aurora | PVM4 20STG 3/4hp | ||
| Chilled Water Pump | CWP-7 | Aurora | PVM4 20STG 3/4hp | ||
| MRI Heat Exchange | HX-4 | Bell & Gossett | P20-DW | ||
| CHW CRAC Unit | CRAC-1 | Liebert | CW106D | ||
| CHW CRAC Unit | CRAC-2 | Liebert | CW106D | ||
| CHW CRAC Unit | CRAC-3 | Liebert | CW106D | ||
| CHW CRAC Unit | CRAC-4 | Liebert | BU102C | ||
| Fan Coil Unit | FCU-E1 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-E2 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-E3 | Trane | (BCXC Blower Coil Air Handler) BCHC054A2 | ELEC 1610 | |
| Fan Coil Unit | FCU-E4 | Trane | (BCXC Blower Coil Air Handler) BCHC090E2 | ELEC 1588 | |
| Fan Coil Unit | FCU-E5 | Trane | (BCXC Blower Coil Air Handler) BCHC090E2 | ELEC 1588 | |
| Fan Coil Unit | FCU-E6 | Trane | (BCXC Blower Coil Air Handler) BCHC090E2 | ELEC 1588 | |
| Fan Coil Unit | FCU-E7 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-E8 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-E9 | Trane | |||
| Fan Coil Unit | FCU-E10 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-E11 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-E12 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-E13 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-E14 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-E15 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-E16 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-E17 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-E18 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-E19 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-E20 | Trane | (BCXC Blower Coil Air Handler) BCHC054A2 | ELEC 5400 | |
| Fan Coil Unit | FCU-E21 | Trane | (BCXC Blower Coil Air Handler) BCHC054A2 | ELEV 5402 | |
| Fan Coil Unit | FCU-E22 | Trane | (BCXC Blower Coil Air Handler) BCHC054A2 | ELEV 5401 | |
| Fan Coil Unit | FCU-E23 | Trane | (BCXC Blower Coil Air Handler) BCHC024A2 | ELEC 5404 | |
| Fan Coil Unit | FCU-E24 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | DENTAL 1419 | |
| Fan Coil Unit | FCU-E25 | Trane | (BCXC Blower Coil Air Handler) BCHC018A2 | MAIL 1542 | |
| Fan Coil Unit | FCU-E26 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-E27 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-W1 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-W2 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-W3 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-W4 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-W5 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-W6 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-W7 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-W8 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-W9 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-W10 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-W11 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-W12 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | COMM | |
| Fan Coil Unit | FCU-W13 | Trane | (BCXC Blower Coil Air Handler) BCHC054A2 | ELEC 5100 | |
| Fan Coil Unit | FCU-W14 | Trane | (BCXC Blower Coil Air Handler) BCHC036A2 | ELEC 5101 |
| Exhaust System | |||||
| Condensate Return Unit | CP-2 | Shipco | 302.5 DSD | ||
| Condensate Return Unit | CP-3 | Shipco | 153 DSD | ||
| Condensate Return Unit | CP-4 | Shipco | 16 DSD | ||
| Fan Curtain | AD-1 | Mars Air system | STD 72-24 | W/ Microswitch | |
| Fan Curtain | AD-2 | Mars Air system | StD 48-14 | W/ Microswitch | |
| Steam Humidifier | H-1 | Dristeem | Ultra-Sorb XV | ||
| Steam Humidifier | H-2 | Dristeem | Ultra-Sorb XV | ||
| Steam Humidifier | H-3 | Dristeem | Ultra-Sorb XV | ||
| Steam Humidifier | H-4 | Dristeem | Ultra-Sorb XV | ||
| Steam Humidifier | H-5 | Dristeem | Ultra-Sorb XV | ||
| Steam Humidifier | H-6 | Dristeem | Ultra-Sorb XV | ||
| Steam Humidifier | H-7 | Dristeem | Ultra-Sorb XV | ||
| Steam Humidifier | H-8 | Dristeem | Ultra-Sorb XV | ||
| Steam Humidifier | H-9 | Dristeem | Ultra-Sorb XV | ||
| Steam Humidifier | H-10 | Dristeem | Ultra-Sorb XV | ||
| Steam Humidifier | H-11 | Dristeem | Ultra-Sorb XV | ||
| Steam Humidifier | H-12 | Dristeem | Ultra-Sorb XV | ||
| Steam Humidifier | H-13 | Dristeem | Ultra-Sorb XV | ||
| Steam Humidifier | H-14 | Dristeem | Ultra-Sorb XV | ||
| Steam Humidifier | H-15 | Dristeem | Ultra-Sorb XV | ||
| Steam Humidifier | H-16 | Dristeem | Ultra-Sorb XV | ||
| Steam Humidifier | H-17 | Dristeem | Ultra-Sorb XV | ||
| Steam Humidifier | H-18 | Dristeem | Ultra-Sorb XV | ||
| Steam Humidifier | H-19 | Dristeem | Ultra-Sorb XV | ||
| Steam Humidifier | H-20 | Dristeem | Ultra-Sorb XV | ||
| Steam Humidifier | H-21 | Dristeem | Ultra-Sorb XV | ||
| Steam Humidifier | H-22 | Dristeem | Ultra-Sorb XV | ||
| Steam Humidifier | H-23 | Dristeem | Ultra-Sorb XV | ||
| Steam Humidifier | H-24 | Dristeem | Ultra-Sorb XV | ||
| Steam Humidifier | H-25 | Dristeem | Ultra-Sorb XV | ||
| Exhaust Fan | EF-1 | Cook | 195CPS | ||
| Exhaust Fan | EF-2 | Cook | 245CPS | ||
| Exhaust Fan | EF-3 | Cook | 225CPS | ||
| Exhaust Fan | EF-4 | Cook | 150CPS | ||
| Exhaust Fan | EF-5 | Cook | 245CPS | ||
| Exhaust Fan | EF-6 | Cook | 165CPS | ||
| Exhaust Fan | EF-7 | Cook | 195CPS | ||
| Exhaust Fan | EF-9A,B | Cook | 70-MHA-SD | ||
| Exhaust Fan | EF-10A,B | Cook | 110-MHA-SD | ||
| Exhaust Fan | EF-11A,B | Cook | 90-MHA-SD | ||
| Exhaust Fan | EF-12A,B | Cook | 110-MHA-SD | ||
| Exhaust Fan | EF-13A,B | Cook | 110-MHA-SD | ||
| Exhaust Fan | EF-13B | Cook | 110-MHA-SD | ||
| Exhaust Fan | EF-14 | Cook | 150CPS | ||
| Exhaust Fan | EF-15 | Cook | 330CPS | ||
| Exhaust Fan | EF-16 | Cook | 365CA-SWS1 | ||
| Exhaust Fan | EF-17 | Cook | 150VH6B | ||
| Exhaust Fan | EF-18 | Cook | 120CPS | ||
| Exhaust Fan | EF-19 | Cook | 90-MHA-SD | ||
| Exhaust Fan | EF-23 | Cook | 100C3B | ||
| Exhaust Fan | EF-24 | Cook | 70CPS | ||
| Exhaust Fan | EF-25 | Cook | 70-MHA-SD | ||
| Exhaust Fan | EF-26 | Cook | 70-MHA-SD | ||
| Exhaust Fan | EF-27 | Cook | 135CPS | ||
| Exhaust Fan | EF-28 | Cook | 120CPS | ||
| Exhaust Fan | EF-29 | Cook | 110-MHA-SD | ||
| Exhaust Fan | EF-30 | Cook | 180CPS | ||
| Exhaust Fan | EF-31 | Cook | 270CPS | ||
| Exhaust Fan | EF-32 | Cook | 330CPS | ||
| Exhaust Fan | EF-33 | Cook | 210CPS | ||
| Exhaust Fan | EF-34 | Cook | 165CPS | ||
| Exhaust Fan | EF-35 | Cook | 180CPS | ||
| Exhaust Fan | EF-36 | Cook | 90-MHA-SD | ||
| Exhaust Fan | EF-37 | Cook | 70C3B | ||
| Exhaust Fan | EF-38 | Cook | 120CPS | ||
| Exhaust Fan | EF-39 | Cook | 80CPS | ||
| Exhaust Fan | EF-40 | Cook | 120CPS | ||
| Exhaust Fan | EF-41 | Cook | 120R3B | ||
| Exhaust Fan | EF-43 | Cook | 100C2B | ||
| Smoke Exhaust Fan | SEF-1 | Cook | 365 SCH 12B | ||
| Smoke Exhaust Fan | SEF-2 | Cook | 365 SCH 12B | ||
| Smoke Exhaust Fan | SEF-3 | Cook | 365 SCH 12B | ||
| Smoke Exhaust Fan | SEF-4 | Cook | 365 SCH 12B |
| Plumbing System | |||||
| Vacuum Pump | MVP-1 | Powerex | MM1252 | ||
| Vacuum Pump | MVP-2 | Powerex | MM1144 | ||
| Vacuum Pump | DLV-1 | Powerex | BIS3HP120 | ||
| Water Heater | DWH-1A/1B | Mason | HSWD 612-72 | ||
| Water Heater | DWH-2A/2B | Mason | HSWD 610-60 | ||
| Domestic Hot Water Pump | CP-1 A+B | Aurora | 326A | ||
| Domestic Hot Water Pump | CP-2 A+B | Aurora | 326A | ||
| Solar Hot Water | SCP-1 | ||||
| Solar Hot Water | SCP-2 | ||||
| Reverse Osmosis | RO-1, ROT-1 | Marlo (Nancrede) | MRO-18K-4H | Design tank K6685 |
| Solar Heating System | ||||
| Solar Panels | SHP-1 | Heliodyne | Gobi 408 | |
| Heat Exchanger | SHX-1 | Heliodyne | HCOM 550 001 |
| Water Treatment | |||||
| Copper Silver Ionization Unit | CSIU-1 | liquitech flow cell | LC10 / QF14-4/4 | not installed yet | |
| Copper Silver Ionization Unit | CSIU-2 | liquitech flow cell | LC10 / QF14-4/4 | not installed yet |
| Medical Gas System | ||||
| Nitrogen | MD-N | Tri-tech Medical | DISS1120 | |
| Oxygen | MD-O | Tri-tech Medical | DISS 1108 | |
| Nitrous Oxide | MD-NO | Tri-tech Medical | ||
| Carbon Dioxide | MD-CD | Tri-tech Medical | ||
| Medical Air Compressor | MAC-1 | Powerex | MST150545 | |
| Medical Air Compressor | DAC-1 | Powerex | MST1005E5HP | |
| Dental Vacuum Units | DLV-1 | Ramvac | BIS3HP120 | |
| Medical Vacuum Unit | MVP-1 | Powerex | MM1252 | |
| Medical Vacuum Unit | MVP-2 | Powerex | MM1144 |
| SYSTEM | ITEM | TAG | Manufacture Name | Manufacture Serial # | Model # | Other Location |
| Parking Garage | ||||||
| Cooling and Exhaust System | ||||||
| Fan Coil | FC-1 | Carrier | 40QNC/38HDF 36K/036 | |||
| Fan Coil | FC-2 | Carrier | 40QNC/38HDF 30K/30 | |||
| Fan Coil | FC-3 | Carrier | 40QNC/38HDF 30K/30 | |||
| Exhaust Fan | EF-1 | Cook | 195CPS | Cannot access roof | ||
| Exhaust Fan | EF-2 | Cook | 245CPS | Cannot access roof | ||
| Exhaust Fan | EF-3 | Cook | 225CPS | Cannot access roof | ||
| Exhaust Fan | EF-4 | Cook | 150CPS | Cannot access roof |
APPENDIX C Door Inventory
| Appendix C - Door Inventory | |||||
| Door Inventory: | Camp Pendleton H-200 (New Hospital) | ||||
| REVISION DATE: April 8, 2013 | |||||
| Notes: | |||||
| N/A* denotes that a manufacturers name is not present on the part or not accessible. | |||||
| PM Procedure: Standard | |||||
| 1. Lubricate all doors as needed. | |||||
| 2. Inspect, cycle, lubricate as needed on automatic door operator mechanisms if applicable. | |||||
| 3. Inspect / Test / Adjust opening preasure, Closing speed, panic devices, hinges, alinment, locks, | |||||
| activation / access devices and other hardware. | |||||
| 4. Inspect and tighten fastners. | |||||
| 5. Complete report of work and recommendations for needed repairs or parts replacements. | |||||
| 6. Two inspections: 1st Inspection February; 2nd Inspection August | |||||
| BLDG. H-200 | |||||
| DOOR # | TYPE | Hand | Direction | Location | HWG |
| 1002A | Q2 | BiPart | NORTH | Entry Vest 1002 | A010 |
| 1002B | Q2 | BiPart | NORTH | Exterior | AD010 |
| 1006A | Q2 | BiPart | WEST | West Entry Vest 1006 | A010 |
| 1006B | Q2 | BiPart | WEST | Exterior | AD010 |
| 1008 | Q1 | O-SX / LH | Courtyard | Vest 1008 | 031 |
| 1008B | Q1 | SX-O / RH | Wait 1003A | 031 |
| 1011 | Q1 | SX-O / RH | Courtyard | Vest 1011 | 031 |
| 1011B | Q1 | O-SX / LH | Waiting 1012 | 031 |
| 1014A | Q1 | SX-O / RH | Courtyard | Vest 1016 | 031 |
| 1014B | Q1 | O-SX / LH | Waiting 1012 | 031 |
| 1016A | Q1 | O-SX / LH | Courtyard | Vest 1016 | 031 |
| 1016B | Q1 | O-SX / LH | Subwait 1017 | 031 |
| 1020 | Q2 | BiPart | Subwait 1044 | Entry Vest 1020 | A010 |
| 1020B | Q2 | BiPart | SOUTH | Exterior | AD010 |
| 1041 | Q1 | O-SX / LH | ER Wait 1016 | ED Vest 1041 | AD011 |
| 1041B | Q2 | BiPart | ED Vest 1041 | Exterior | AD010 |
| 1679 | Q2 | BiPart | Emergency CORR-164 | Vest 1679 | A010 |
| 1679B | Q2 | BiPart | Vest 1679 | Exterior | AD010 |
| 2002A | Q2 | BiPart | CORR C-205 | North Entry Vest 2002 | A010 |
| 2002B | Q2 | BiPart | North Entry | Exterior | AD010 |
| Hardware Group #031 |
| Courtyar Doors 1008/1008B, 1011/1011B, 1016A/1016B - No mechanical or electric locks. Breakaway function @ slide door only |
| Description | Qty | Model No. | Mfg | Finish | Finish |
| Motion / Presence Detector | 2 | Wizard | BEA | Black | |
| Holding Beam Set | 2 | 313710 | Stanley | N/A | |
| Rotary Function Selector Key Switch | 1 | 413584 | Stanley | Black | |
| Decal Set | 1 | ANSI 156.10 | Stanley | N/A |
| Hardware Group #A010 |
| Interior Vestibule Doors 1002A, 1006A, 1020, 1679, 2002A - No mechanical or electric locks. Breakaway function @ slide doors only |
| Description | Qty | Model No. | Mfg | Finish | Finish |
| Motion / Presence Detector | 2 | Wizard | BEA | Black | |
| Holding Beam Set | 2 | 313710 | Stanley | N/A | |
| Rotary Function Selector Key Switch | 1 | 413584 | Stanley | Black | |
| Decal Set | 1 | ANSI 156.10 | Stanley | N/A |
| Hardware Group #AD010 |
| Exterior Vestibule Doors 1002B, 1006B, 1020 Exterior, 1041 Exterior, 1679 Exterior, 2002B-TRO Painc Device / Breakaway @ slide doors |
| Description | Qty | Model No. | Mfg | Finish | Finish |
| Motion / Presence Detector | 2 | Wizard | BEA | Black | |
| Holding Beam Set | 2 | 313710 | Stanley | N/A | |
| Rotary Function Selector Key Switch | 1 | 413584 | Stanley | Black | |
| Decal Set | 1 | ANSI 156.10 | Stanley | N/A | |
| Slide Lock, Electric Solenoid | 1 | 313985 | Stanley | N/A | |
| Recessed Panic Exit | 2 | 2000AC | Stanley | 628 |
| Hardware Group #AD011 |
| Interior Vestible Door Emergency Depart 1041 Interior, No mechanical or electric locks. Breakaway function @ slide door only. |
| Description | Qty | Model No. | Mfg | Finish | Finish |
| Motion / Presence Detector | 2 | Wizard | BEA | Black | |
| Holding Beam Set | 2 | 313710 | Stanley | N/A | |
| Rotary Function Selector Key Switch | 1 | 413584 | Stanley | Black | |
| Decal Set | 1 | ANSI 156.10 | Stanley | N/A |
&P
APPENDIX I Valves
| APPENDIX I - MAIN ISOLATING VALVES | |||
| DOMESTIC HOT WATER SYSTEM | |||
| *** Need to Update 8 Apr 13 *** | |||
| SHUT OFFS | PLAN NO. | TAG NO. | LOCATION |
| FOR ENTIRE GROUND FLOOR | V-67 | ECS | |
| V-69 | ECS | ||
| FOR NORTH MAIN OF GROUND FLOOR | V-69 | ECS | |
| FOR SOUTH MAIN OF GROUND FLOOR | V-67 | ECS | |
| FOR GROUND, 1ST & 2ND FLOORS | V-71 | G-222 | |
| V-72 | G-222 | ||
| FOR 1ST & 2ND FLOORS | V-55 | ABOVE CEILING RM 1-543 | |
| V-56 | ABOVE CEILING RM 1-543 | ||
| V-65 | ABOVE CEILING RM 1-506 | ||
| OR | V-65 | ABOVE CEILING RM 1-506 | |
| V-66 | ECS | ||
| FOR 3RD - 8TH FLOORS, | V-77 | ABOVE CEILING RM 1-128 | |
| SOUTH TOWER RISERS 5 & 6 | V-78 | ABOVE CEILING RM 1-127 | |
| FOR 3RD - 8TH FLOORS, | |||
| NORTH TOWER - RISERS 7 & 8 | V-68 | ECS | |
| FOR 3RD & 4TH FLOORS | V-27 | PIPE SHAFT #1 | |
| SOUTH TOWER | V-31 | PIPE SHAFT #2 | |
| FOR 3RD & 4TH FLOORS | V-35 | PIPE SHAFT #3 | |
| NORTH TOWER | V-38 | PIPE SHAFT #4 | |
| *ECS=EAST CRAWL SPACE | |||
| APPENDIX I - MAIN ISOLATING VALVES | |||
| DOMESTIC COLD WATER SYSTEM | |||
| SHUT OFFS | PLAN NO. | TAG NO. | LOCATION |
| FOR ENTIRE GROUND FLOOR | V-67 | S R | ECS |
| V-69 | ECS | ||
| FOR NORTH MAIN OF GROUND FLOOR | V-69 | ECS | |
| FOR SOUTH MAIN OF GROUND FLOOR | V-67 | ECS | |
| FOR GROUND, 1ST & 2ND FLOORS | V-71 | G-222 | |
| V-72 | G-222 | ||
| FOR 1ST & 2ND FLOORS | V-55 | ABOVE CEILING RM 1-543 | |
| V-56 | ABOVE CEILING RM 1-543 | ||
| V-65 | ABOVE CEILING RM 1-506 | ||
| OR | V-65 | ABOVE CEILING RM 1-506 | |
| V-66 | ECS | ||
| FOR 3RD - 8TH FLOORS, SOUTH | V-77 | ABOVE CEILING RM 1-128 | |
| TOWER - RISERS 5 & 6 | V-78 | ABOVE CEILING RM 1-127 | |
| FOR 3RD - 8TH FLOORS, NORTH | V-68 | ECS | |
| TOWER - RISERS 7 & 8 | |||
| FOR 3RD & 4TH FLOORS SOUTH | V-27 | PIPE SHAFT #1 | |
| TOWER | V-31 | PIPE SHAFT #2 | |
| FOR 3RD & 4TH FLOORS NORTH | V-35 | PIPE SHAFT #3 | |
| TOWER | V-38 | PIPE SHAFT #4 | |
| APPENDIX I - MAIN ISOLATING VALVES | |||
| DOMESTIC COLD WATER SYSTEM | |||
| SHUT OFFS | PLAN NO. | TAG NO. | LOCATION |
| FOR 5TH & 6TH FLOORS | V-15 | S R | PIPE SHAFT #2 |
| SOUTH TOWER | V-18 | PIPE SHAFT #1 | |
| FOR 5TH & 6TH FLOORS | V-21 | PIPE SHAFT #3 | |
| NORTH TOWER | V-24 | PIPE SHAFT #4 | |
| FOR 7TH & 8TH FLOORS | V-9 | PIPE SHAFT #2 | |
| SOUTH TOWER | V-12 | PIPE SHAFT #1 | |
| FOR 7TH & 8TH FLOORS | V-3 | PIPE SHAFT #2 | |
| NORTH TOWER | V-6 | PIPE SHAFT #4 |
APPENDIX J Ice Machines
| APPENDIX J - HOSPITAL ICE MACHINES - CAMP PENDLETON |
| *** Need to Update 8 Apr 13 *** |
LOCATION MAKE MODEL SERIAL NUMBER
| Same Day Surgery | Follett | LC12 | 12CI400A / OMR4 |
| Physical Therapy | Scotsman | FME804AS-B1 | D7101320017283 |
| Galley | Scotsman | CME1356AS | 717938-06S |
| Labor & Delivery | Follett | LC12/12CI400A | C60998-341 08 |
| **Note** |
| Galley has two new ice dispensers and one large ice machine. |
| These two need to be added; detailed info. unavailable at this time |