Amendment4 C Sheets 2 of 2.pdf
PDF 38 MB Posted
- Attached to
- Pajaro River Reach 6
- Solicitation number
- W912P725BA012
About this file
These demolition plan sheets (C-07 through C-14) detail the demolition requirements for the Pajaro River Reach 6 levee and floodwall construction project in Santa Cruz County, California. The documents provide comprehensive site-specific instructions for removing existing structures, utilities, vegetation, and agricultural infrastructure along both the right bank (RB) and left bank (LB) of the Corralitos Creek project area. Key demolition activities include removing tree stumps (with specific square footage noted for each section), relocating or removing utility poles, storm drain and irrigation pipes, fences, agricultural structures, and clearing temporary agricultural fields within the construction limits.
The demolition plans specify that certain removals will be completed by landowners prior to construction, while the contractor is responsible for removing remaining structures, clearing site posts, and managing utility relocations. The documents are part of Amendment 4 and cover project stations from RB0+00 to RB61+70 and LB0+00 to LB92+85, with detailed notes indicating that buildings, pump stations, utility services, and crops will be removed or relocated per real estate purchase agreements. The plans are part of the U.S. Army Corps of Engineers project for constructing 2.6 miles of flood risk management levees with approximately 111,600 cubic yards of fill and 1,500 linear feet of floodwalls along the Corralitos Creek.
View the file
Other files
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
X
X
X
X
X
X
X
NORTH
NORTH
CORRALITOS CREEK
RB32+00
RB34+00
RB36+00
RB38+00
RB40+00
RB42+00
R&D EXST FN
W/IN CONSTR LIMITS
PRIOR TO CONSTR
C&G EXST TEMP AG
FIELD W/IN CONSTR
LIMITS
PROTECT EXST FN,
OUTSIDE CONSTR LIMITS
RB CONSTR LIMITS
(FOLLOW PFCE ON LANDSIDE)
EXST TREES AND/OR TREE
STUMPS TO BE REMOVED,
1,710 SF
RB LEVEE LIMITS
EXST TREES AND/OR TREE
STUMPS TO BE REMOVED,
1,800 SF
RB-LINE
PROTECT EXST AG FIELD AND TEMP
AG STRUCT, OUTSIDE CONSTR LIMITS
EXST TEMP AG STRUCT, UNDG &
AG PIPES, FENCES AND
APPURTENANCES. R&D TO BE
COMPLETED BY LANDOWNERS
W/IN CONSTR LIMITS PRIOR TO
CONSTR, SEE NOTE 1.
NORTH
SDSD
CORRALITOS CREEK
CORRALITOS CREEK
RB
+0
RB22+00
RB24+00
RB26+00
RB28+00
RB30+00
RB32+00
EXST TEMP AG STRUCT, UNDG & AG PIPES,
FENCES AND APPURTENANCES. R&D TO BE
COMPLETED BY LANDOWNERS W/IN CONSTR
LIMITS PRIOR TO CONSTR, SEE NOTE 1.
RB LEVEE LIMITS
C&G EXST TEMP AG FIELD
W/IN CONSTR LIMITS
RB CONSTR LIMITS
(FOLLOW PFCE ON LANDSIDE)
R&D EXST SITE POST
PRIOR TO CONSTR
R&D EXST SITE POST
PRIOR TO CONSTR
EXST TREES AND/OR TREE
STUMPS TO BE REMOVED,
625 SF
PROTECT EXST AG FIELD AND TEMP
AG STRUCT, OUTSIDE CONSTR LIMITS
RB-LINE
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
A3
GE
O -C
E& G
JV
Ÿ
Ba nc ro ft
W ay
, B er ke le y
CA
OF
D
ES
IG
N
F
IR
M
SCALE IN FEET
40 0 8040
1" = 40'
PLAN STA RB21+00 TO RB32+00
MATCH LI
NE
STA R
B21
+0 0 (
SEE SHEET C
-07
1" = 40'
PLAN STA RB32+00 TO RB43+00
M
AT
CH
L
IN
E
ST
A
RB
+0
(S
EE
S
HE
ET
C
-0 9)
\\H
AL
EY
AL
D R
IC
H
.C O
M \S
H
AR
E\ G
R
AN
IT
E\
\2
0-
A3 G
EO
C
EG
JV
-P
AJ
AR
O
R
IV
ER
LE
VE
ER
EA
C
H
ES
6& 5\
AU
TO
C
AD
-R
EA
C H
6\
SH
EE
TS
\0
-0
-C
-D
EM
O
LI
TI
O
N -P
LA
N
-R B.
D W
G 6:
:4
PM
/1
0/
AE
C _B
&W .S
TB
KD
R O
ZY
N
SK
A
NOTES
1. BUILDING, APPURTENANCE, PUMP STATION/PIPES, UTILITY SERVICES, HOOP HOUSES/CROPS, WILL BE REMOVED OR RELOCATED BY OTHERS PER REAL ESTATE PURCHASE AGREEMENT. CONTRACTOR TO R&D AND C&G WHAT IS REMAINED ONSITE AFTER THE WORK BY OTHERS IS
COMPLETED. SEE NOTES 2 AND 3 FOR WORK TO BE COMPLETED BY CONTRACTOR.
2. CONTRACTOR SHALL R&D OF EXISTING IRRIGATION, STORM DRAIN PIPES, AC PAVEMENT, AND FENCES WITHIN THE CONSTRUCTION LIMITS.
CONTRACTOR SHALL ALSO RELOCATE, AS NECESSARY, ANY ACTIVE UTILITIES OR REMOVE ANY ABANDONED UTILITIES NOT IDENTIFIED ON
THE PLANS LOCATED WITHIN THE CONSTRUCTION LIMITS.
3. CONTRACTOR TO REMOVE TREE STUMPS. TREE SURVEY IS INCLUDED AS ATTACHMENT TO CONTRACT AMENDMENT.
SA
N
F R
AN
C
IS
C
O D
IS
TR
IC
T
G O
LD
EN
G
AT
E
AV
E.
, 4
TH
F
LO
O
R
SA
N F
R
AN
C
IS
C O
, C A
2-
W
2P
C
XX
JU
LY
AN
SI
D
W
2P
5B A0
SA
N
TA
C
R U
Z C
O U
N
TY
, C
AL
IF
O
R N
IA
PA
JA
R
O R
IV
ER
A T
W
AT
SO
N
VI
LL
E, C
A R
EA
C
H
SO
LI
C
IT
AT
IO
N
C-08
D
EM
O
LI
TI
O
N P
LA
N
R
IG
H T
BA
N
K
ST
A R
B2 1+
T
O R
B4 3+
E.
Z
AN
E
J.
B
U
ST
AM
AN
TE
J.
B
U
ST
AM
AN
TE
P.
G
R
EG
O R
Y
M
AT
CH
L
IN
E
M
AT
C H
L
IN
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
JU
L
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
AU
G
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
DENSE TREE
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DENSE TREE
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DENSE TREE
NORTH
SA
N
SA
N
W W
W W
W
W W
W
W
W
COMM
COMM
COMM
COMM
C O
M M
CO
M
M
C O
M M
CO
M
M
C O
M
ME
E E
E E
E E
E E
E
E
E
E
E E
E E
E E
E E
E
E
E E
E E
E
E E
E E
E E
E E
E
E
E
G
G
G G
G G
G G
G
G
G
G G
G
G
G
G
G
SD
COMM
COMM
TCE
TCE
TCE
TCE
TCE
TCE
TCE
TCE
TCE
CORRALIT
OS C
REEK
PROTECT EXST GAS SERVICE LINE,
OUTSIDE CONSTR LIMITS
RB0+00
RB2+00
RB4+00
RB6+00
RB8+00 RB10+00
EXST COMM UTIL WILL BE REMOVED
PRIOR TO CONSTR,
W/IN CONSTR LIMITS
R&D EXST FN
RB LEVEE LIMITS
C&G EXST AG FIELD
W/IN CONSTR LIMITS
PROTECT EXST AG
FIELD, OUTSIDE CONSTR
LIMITS
EXST TEMP AG STRUCT, UNDG & AG PIPES, FENCES
AND APPURTENANCES. R&D TO BE COMPLETED BY
LANDOWNERS W/IN CONSTR LIMITS PRIOR TO
CONSTR, SEE NOTE 1.
RB CONSTR LIMITS
(FOLLOW PFCE ON LANDSIDE)
R&D EXST SD UTIL,
W/IN CONSTR LIMITS
R&D EXST FN
EXST TREES AND/OR TREE STUMPS
TO BE REMOVED, 480 SF
PROTECT EXST GAS METER MANIFOLD
PROTECT EXST FN ALONG PL
APN: 04823113,
OUTSIDE OF CONSTR LIMITS
PROTECT EXST FN ALONG PL
APN: 04823113,
OUTSIDE OF CONSTR LIMITS
EXST TREES AND/OR TREE
STUMPS TO BE REMOVED,
480 SF
R&D EXST J-BOX
PRIOR TO CONSTR
EXST TREES AND/OR TREE
STUMPS TO BE REMOVED,
765 SF
EXST TREES AND/OR TREE
STUMPS TO BE REMOVED,
5,480 SF
EXST TREES AND/OR TREE
STUMPS TO BE REMOVED,
SEE ABOVE SF
EXST TREES AND/OR TREE
STUMPS TO BE REMOVED,
440 SF
RB-LINE
STAGING AREA 1, C&G AS REQD
NORTH
NORTH
CORRALITOS CREEKRB10+00
RB12+00
RB14+00
RB16+00
RB18+00
RB20+00
RB LE
VEE LI
MITS
EXST TEMP AG STRUCT, UNDG & AG
PIPES, FENCES AND APPURTENANCES.
R&D TO BE COMPLETED BY
LANDOWNERS W/IN CONSTR LIMITS
PRIOR TO CONSTR, SEE NOTE 1.
RB LEVEE LIMITSRB CONSTR LIMITS
(FOLLOW PFCE ON LANDSIDE)
EXST TREES AND/OR TREE STUMPS
TO BE REMOVED, 50 SF
EXST TREES AND/OR TREE
STUMPS TO BE REMOVED,
680 SF EXST TREES AND/OR TREE
STUMPS TO BE REMOVED,
570 SF
EXST TREES AND/OR TREE
STUMPS TO BE REMOVED,
370 SF
EXST T
REES A
ND/O
R TR
EE
STU
MPS TO
B E R
EMOVED,
0 S F
EXST TREES AND/OR
TREE STUMPS TO BE REMOVED,
1,455 SF
EXST TREES AND/OR TREE
STUMPS TO BE REMOVED,
SEE ABOVE SF
PROTECT EXST AG FIELD AND TEMP
AG STRUCT, OUTSIDE CONSTR LIMITS
RB-LINE
SCALE IN FEET
40 0 8040
1" = 40'
PLAN STA RB0+00 TO RB10+00
1" = 40'
PLAN STA RB10+00 TO RB21+00
M
AT
C H
L
IN
E S
TA
R
B2 1+
SE
E
SH
EE
T C
-0 8)
\\H
AL
EY
AL
D R
IC
H
.C O
M \S
H
AR
E\ G
R
AN
IT
E\
\2
0-
A3 G
EO
C
EG
JV
-P
AJ
AR
O
R
IV
ER
LE
VE
ER
EA
C
H
ES
6& 5\
AU
TO
C
AD
-R
EA
C H
6\
SH
EE
TS
\0
-0
-C
-D
EM
O
LI
TI
O
N -P
LA
N
-R B.
D W
G 6:
:4
PM
/1
0/
AE
C _B
&W .S
TB
KD
R O
ZY
N
SK
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
A3
GE
O -C
E& G
JV
Ÿ
Ba nc ro ft
W ay
, B er ke le y
CA
OF
D
ES
IG
N
F
IR
M
NOTES
1. BUILDING, APPURTENANCE, PUMP STATION/PIPES, UTILITY SERVICES, HOOP HOUSES/CROPS, WILL BE REMOVED OR RELOCATED BY OTHERS PER REAL ESTATE PURCHASE AGREEMENT. CONTRACTOR TO R&D AND C&G WHAT IS REMAINED ONSITE AFTER THE WORK BY OTHERS IS
COMPLETED. SEE NOTES 2 AND 3 FOR WORK TO BE COMPLETED BY CONTRACTOR.
2. CONTRACTOR SHALL R&D OF EXISTING IRRIGATION, STORM DRAIN PIPES, AC PAVEMENT, AND FENCES WITHIN THE CONSTRUCTION LIMITS.
CONTRACTOR SHALL ALSO RELOCATE, AS NECESSARY, ANY ACTIVE UTILITIES OR REMOVE ANY ABANDONED UTILITIES NOT IDENTIFIED ON
THE PLANS LOCATED WITHIN THE CONSTRUCTION LIMITS.
3. CONTRACTOR TO REMOVE TREE STUMPS. TREE SURVEY IS INCLUDED AS ATTACHMENT TO CONTRACT AMENDMENT.
SA
N
F R
AN
C
IS
C
O D
IS
TR
IC
T
G O
LD
EN
G
AT
E
AV
E.
, 4
TH
F
LO
O
R
SA
N F
R
AN
C
IS
C O
, C A
2-
W
2P
C
XX
JU
LY
AN
SI
D
W
2P
5B A0
SA
N
TA
C
R U
Z C
O U
N
TY
, C
AL
IF
O
R N
IA
PA
JA
R
O R
IV
ER
A T
W
AT
SO
N
VI
LL
E, C
A R
EA
C
H
SO
LI
C
IT
AT
IO
N
C-07
D
EM
O
LI
TI
O
N P
LA
N
R
IG
H T
BA
N
K
ST
A R
B0 +0
TO
R B2
1+
E.
Z
AN
E
J.
B
U
ST
AM
AN
TE
J.
B
U
ST
AM
AN
TE
P.
G
R
EG
O R
Y
M
AT
C H
L
IN
E
MATCH LINE
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
JU
L
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
AU
G
AutoCAD SHX Text
RIPRAP
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DP
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DENSE TREE
AutoCAD SHX Text
ASPH
AutoCAD SHX Text
CONC
AutoCAD SHX Text
LEVEE PATH
AutoCAD SHX Text
E LAKE AVE
AutoCAD SHX Text
ASPH
AutoCAD SHX Text
ASPH
AutoCAD SHX Text
ASPH
AutoCAD SHX Text
ASPH
AutoCAD SHX Text
GATE
AutoCAD SHX Text
RIPRAP
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
CONC BRIDGE
AutoCAD SHX Text
DENSE TREE
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DP
AutoCAD SHX Text
DENSE TREE
NORTH
NORTH
EE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
CORRALITOS CREEK
RB61+70
RB52+00
RB54+00
RB56+00
RB58+00
RB60+00
PROTECT COMM UTIL,
OUTSIDE CONSTR LIMITS
PROTECT EXST BLDG
OUTSIDE CONSTR LIMITS
RB LEVEE LIMITS
R&D EXST COMM UTIL
PRIOR TO CONSTR
PROTECT EXST OH POLE,
OUTSIDE CONSTR LIMITS
RB CONSTR LIMITS
(FOLLOW PFCE ON LANDSIDE)
RB-LINE
W/IN CONSTR LIMITS
C&G REMAINING MATERIAL, BLDG WILL BE
RELOCATED BY PROPERTY OWNER
R&D EXST COMM UTIL
PRIOR TO CONSTR
EXST TREES AND/OR TREE
STUMPS TO BE REMOVED,
750 SF
R&D EXST UTIL
POLE PRIOR
TO CONSTR
STAGING AREA 4,
C&G AS REQD
EXST TEMP AG STRUCT, UNDG & AG PIPES,
FENCES AND APPURTENANCES. R&D TO BE
COMPLETED BY LANDOWNERS W/IN CONSTR
LIMITS PRIOR TO CONSTR, SEE NOTE 1.
X X
X X
NORTH
X X
X X
X
E E
E E
E E
E E
E E
E E
E
TC
E
TCE
TCE
TC
E
CORRALITOS CREEK
RB44+00 RB46+00 RB48+00
RB50+00 RB52+00
RB5
4+
CORRALITOS CREEK
RB LEVEE LIMITS
PROTECT EXST FN,
OUTSIDE CONSTR LIMITS
PROTECT EXST BLDG
OUTSIDE CONSTR LIMITS
RB CONSTR LIMITS
(FOLLOW PFCE ON LANDSIDE)
R&D EXST FN
W/IN CONSTR LIMITS
PRIOR TO CONSTR
R&D EXST FN W/IN CONSTR
LIMITS PRIOR TO CONSTR
EXST TREES AND/OR TREE
STUMPS TO BE REMOVED,
3,975 SF
RELOCATE PG&E FACILITY
PRIOR TO CONSTR
R&D EXST SITE POST
PRIOR TO CONSTR
EXST TREES AND/OR TREE
STUMPS TO BE REMOVED,
8182 SF
EXST TREES AND/OR TREE
STUMPS TO BE REMOVED,
578 SF
RB-LINE STAGING AREA 4,
C&G AS REQD
EXST TEMP AG STRUCT, UNDG &
AG PIPES, FENCES AND
APPURTENANCES. R&D TO BE
COMPLETED BY LANDOWNERS
W/IN CONSTR LIMITS PRIOR TO
CONSTR, SEE NOTE 1.
SCALE IN FEET
40 0 8040
1" = 40'
PLAN STA RB43+00 TO RB54+00
1" = 40'
PLAN STA RB54+00 TO RB61+70
MATCH LINE
MATCH LINE
\\H
AL
EY
AL
D R
IC
H
.C O
M \S
H
AR
E\ G
R
AN
IT
E\
\2
0-
A3 G
EO
C
EG
JV
-P
AJ
AR
O
R
IV
ER
LE
VE
ER
EA
C
H
ES
6& 5\
AU
TO
C
AD
-R
EA
C H
6\
SH
EE
TS
\0
-0
-C
-D
EM
O
LI
TI
O
N -P
LA
N
-R B.
D W
G 6:
:4
PM
/1
0/
AE
C _B
&W .S
TB
KD
R O
ZY
N
SK
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
A3
GE
O -C
E& G
JV
Ÿ
Ba nc ro ft
W ay
, B er ke le y
CA
OF
D
ES
IG
N
F
IR
M
NOTES
1. BUILDING, APPURTENANCE, PUMP STATION/PIPES, UTILITY SERVICES, HOOP HOUSES/CROPS, WILL BE REMOVED OR RELOCATED BY OTHERS PER REAL ESTATE PURCHASE AGREEMENT. CONTRACTOR TO R&D AND C&G WHAT IS REMAINED ONSITE AFTER THE WORK BY OTHERS IS
COMPLETED. SEE NOTES 2 AND 3 FOR WORK TO BE COMPLETED BY CONTRACTOR.
2. CONTRACTOR SHALL R&D OF EXISTING IRRIGATION, STORM DRAIN PIPES, AC PAVEMENT, AND FENCES WITHIN THE CONSTRUCTION LIMITS.
CONTRACTOR SHALL ALSO RELOCATE, AS NECESSARY, ANY ACTIVE UTILITIES OR REMOVE ANY ABANDONED UTILITIES NOT IDENTIFIED ON
THE PLANS LOCATED WITHIN THE CONSTRUCTION LIMITS.
3. CONTRACTOR TO REMOVE TREE STUMPS. TREE SURVEY IS INCLUDED AS ATTACHMENT TO CONTRACT AMENDMENT.
SA
N
F R
AN
C
IS
C
O D
IS
TR
IC
T
G O
LD
EN
G
AT
E
AV
E.
, 4
TH
F
LO
O
R
SA
N F
R
AN
C
IS
C O
, C A
2-
W
2P
C
XX
JU
LY
AN
SI
D
W
2P
5B A0
SA
N
TA
C
R U
Z C
O U
N
TY
, C
AL
IF
O
R N
IA
PA
JA
R
O R
IV
ER
A T
W
AT
SO
N
VI
LL
E, C
A R
EA
C
H
SO
LI
C
IT
AT
IO
N
C-09
D
EM
O
LI
TI
O
N P
LA
N
R
IG
H T
BA
N
K
ST
A R
B4 3+
T
O R
B6 1+
E.
Z
AN
E
J.
B
U
ST
AM
AN
TE
J.
B
U
ST
AM
AN
TE
P.
G
R
EG
O R
Y
M
ATC
H
LIN
E STA R
B43+00 (SEE SH
EET C
-08)
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
JU
L
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
AU
G
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
PIPE
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DENSE TREE
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
DENSE TREE
AutoCAD SHX Text
DENSE TREE
AutoCAD SHX Text
WOOD PILE
AutoCAD SHX Text
WOOD PILE
AutoCAD SHX Text
DP
AutoCAD SHX Text
WOOD PILE
AutoCAD SHX Text
WOOD PILE
AutoCAD SHX Text
WOOD PILE
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DENSE TREE
CULTIVATED
E LAKE AVE
SA
N
SA
N
SA
N
SAN
W W
W W
W W
W
W W
W
W
COMM
COMM
COMM
COMM
COMM
C O
M M
C O
M M
C O
M M
C O
M M
COMM
COMM
C O
M
MCOMM
COMM
C O
M M
C O
M M
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMMCOMM
C O
M M
C O
M M
C O
M M
C O
M M
COMM
COMM
C O
M M
C O
M M
C O
M M
C O
M M
E
E
E
E
E
E
E
E E
EE
E
E
E
E E
E E
E E
E E
E
E E
E E
E E
E E
E E
E
E E
E E
E G G
G G
G
G
G
G
G G
G
GG
SD
SD
COMM
COMM
COMM
COMM
CORRALITOS CREEK
PROTECT EXST COMM UTIL,
OUTSIDE CONSTR LIMITS
R&D EXST ASPHALT
R&D EXST FN
R&D EXIST AC PAVEMENT, FN,
AND REMAINING
APPURTENANCES AFTER DEMO
BY OTHERS ARE COMPLETED
EXST DRAINAGE
DITCH
PROTECT EXST AG FIELDS,
OUTSIDE CONSTR LIMITS
LB LEVEE LIMITS
R&D BY OTHERS. RELOCATE OR
TERMINATE UTILITY SERVICES BY
OTHERS. CONTRACTOR WILL C&G
WHAT REMAINS
LB CONSTR LIMITS
(FOLLOW PFCE ON LANDSIDE)
R&D EXST UTIL POLE
PRIOR TO CONSTR
PROTECT EXST WATER LINE,
OUTSIDE CONSTR LIMITS
PROTECT EXST UTIL POLE,
OUTSIDE CONSTR LIMITS
TREES AND/OR TREE
STUMPS TO BE
REMOVED, 4870 SF
R&D EXST SD PIPES
PRIOR TO CONSTR
R&D EXST INLET
PRIOR TO CONSTR
R&D EXST SITE POST
PRIOR TO CONSTR
TREES AND/OR TREE
STUMPS TO BE
REMOVED, 470 SF
TREES AND/OR TREE
STUMPS TO BE
REMOVED, 8535 SF
C&G EXST AG FIELD
W/IN CONSTR LIMITS
EXST TEMP AG STRUCT, UNDG & AG PIPES, FENCES
AND APPURTENANCES. R&D TO BE COMPLETED BY
LANDOWNERS W/IN CONSTR LIMITS PRIOR TO
CONSTR, SEE NOTE 1.
LB-LINE
NORTH
LB0+00
LB1+00
LB2+00
LB3+00
LB4+00
LB5+00 LB6+00
LB7+00
LB8+00
LB9+00
LB10+00
E E
E E
CORRALITOS CREEKC&G EXST TREES, STUMPS AND/OR SHRUBS,
W/IN CONSTR LIMITS
EXST TEMP AG STRUCT, UNDG & AG PIPES, FENCES
AND APPURTENANCES. R&D TO BE COMPLETED BY
LANDOWNERS W/IN CONSTR LIMITS PRIOR TO CONSTR,
SEE NOTE 1.
LB LEVEE LIMITS
LB CONSTR LIMITS
(FOLLOW PFCE ON LANDSIDE)
R&D EXIST SD PIPES
W/IN CONSTR LIMITS
BY CONTRACTOR
R&D EXIST SD PIPES W/IN CONSTR
LIMITS BY CONTRACTOR
R&D EXST UTIL POLE
PRIOR TO CONSTR
PROTECT EXST TEMP AG STRUCT,
OUTSIDE CONSTR LIMITS
TREES AND/OR TREE STUMPS
TO BE REMOVED, 870 SF
TREES AND/OR TREE STUMPS
TO BE REMOVED, 2025 SF
TREES AND/OR TREE
STUMPS TO BE REMOVED,
3127 SF
R&D EXST SITE POST
PRIOR TO CONSTR
PROTECT EXST AG FIELD AND TEMP
AG STRUCT, OUTSIDE CONSTR LIMITS
NORTH
LB-LINE
STAGING AREA 3,
C&G AS REQD
LB21+00
LB10+00
LB11+00 LB12+00
LB13+00
LB14+00
LB15+00
LB16+00
LB17+00
LB18+00
LB19+00
LB20+00
LB21+00
SCALE IN FEET
40 0 8040
1" = 40'
PLAN STA LB0+00 TO LB10+00
1" = 40'
PLAN STA LB10+00 TO LB21+00
\\H
AL
EY
AL
D R
IC
H
.C O
M \S
H
AR
E\ G
R
AN
IT
E\
\2
0-
A3 G
EO
C
EG
JV
-P
AJ
AR
O
R
IV
ER
LE
VE
ER
EA
C
H
ES
6& 5\
AU
TO
C
AD
-R
EA
C H
6\
SH
EE
TS
\0
-0
-C
-D
EM
O
LI
TI
O
N -P
LA
N
-L B.
D W
G 6:
:1
PM
/4
/2
AE
C _B
&W .S
TB
EZ
AN
E
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
A3
GE
O -C
E& G
JV
Ÿ
Ba nc ro ft
W ay
, B er ke le y
CA
OF
D
ES
IG
N
F
IR
M
M
AT
CH
L
IN
E
M
ATC
H
LIN
E STA: LB21+00 (SEE SH
EET C
-11) M
ATC
H
LIN
E
SA
N
F R
AN
C
IS
C
O D
IS
TR
IC
T
G O
LD
EN
G
AT
E
AV
E.
, 4
TH
F
LO
O
R
SA
N F
R
AN
C
IS
C O
, C A
2-
W
2P
C
XX
JU
LY
AN
SI
D
W
2P
5B A0
SA
N
TA
C
R U
Z C
O U
N
TY
, C
AL
IF
O
R N
IA
PA
JA
R
O R
IV
ER
A T
W
AT
SO
N
VI
LL
E, C
A R
EA
C
H
SO
LI
C
IT
AT
IO
N
C-10
D
EM
O
LI
TI
O
N P
LA
N
LE
FT
B
AN
K
ST
A
LB
0+
T O
L B2
1+
E.
Z
AN
E
K.
M
AL
IG
K.
M
AL
IG
P.
G
R
EG
O R
Y
NOTES
1. BUILDING, APPURTENANCE, PUMP STATION/PIPES, UTILITY SERVICES, HOOP HOUSES/CROPS, WILL BE REMOVED OR RELOCATED BY OTHERS PER REAL ESTATE PURCHASE AGREEMENT. CONTRACTOR TO R&D AND C&G WHAT IS REMAINED ONSITE AFTER THE WORK BY
OTHERS IS COMPLETED. SEE NOTES 2 AND 3 FOR WORK TO BE COMPLETED BY CONTRACTOR.
2. CONTRACTOR SHALL R&D OF EXISTING STORM DRAIN PIPES, AC PAVEMENT, AND FENCES WITHIN THE CONSTRUCTION LIMITS.
CONTRACTOR SHALL ALSO RELOCATE, AS NECESSARY, ANY ACTIVE UTILITIES OR REMOVE ANY ABANDONED UTILITIES NOT IDENTIFIED ON
THE PLANS LOCATED WITHIN THE CONSTRUCTION LIMITS.
3. CONTRACTOR TO REMOVE TREE STUMPS. TREE SURVEY INCLUDED AS ATTACHMENT TO CONTRACT AMENDMENT.
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
JU
L
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
AU
G
AutoCAD SHX Text
RIPRAP
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
CONC
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DENSE TREE
AutoCAD SHX Text
CONC
AutoCAD SHX Text
DP
AutoCAD SHX Text
CONC
AutoCAD SHX Text
ASPH
AutoCAD SHX Text
ASPH
AutoCAD SHX Text
CONC
AutoCAD SHX Text
ASPH
AutoCAD SHX Text
CORRALITOS CREEK
AutoCAD SHX Text
ASPH
AutoCAD SHX Text
CONC BRIDGE
AutoCAD SHX Text
ASPH
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DP
AutoCAD SHX Text
DP
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
CONC
AutoCAD SHX Text
DENSE TREE
AutoCAD SHX Text
DENSE TREE
CORRALITOS CREEK
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
SDSD
CORRALITOS CREEK
R&D EXIST PIPES,
W/IN CONSTR LIMITS
PRIOR TO CONSTR
PROTECT EXST TEMP AG STRUCT,
OUTSIDE CONSTR LIMITS
PROTECT EXST AG FIELDS,
OUTSIDE CONSTR LIMITSR&D EXST TEMP AG FIELD, UNDG & ABVG PIPES, FENCES
AND APPURTENANCES, SEE NOTE 1
LB LEVEE LIMITS
LB CONSTR LIMITS
(FOLLOW PFCE ON LANDSIDE)
R&D EXIST SD PIPES W/IN
CONSTR LIMITS
C&G OR TRIM EXST TREES,
TREE STUMPS AND/OR SHRUBS
W/IN CONSTR LIMITS
EXST TEMP AG STRUCT, UNDG & AG PIPES,
FENCES AND APPURTENANCES. R&D TO BE
COMPLETED BY LANDOWNERS W/IN CONSTR
LIMITS PRIOR TO CONSTR, SEE NOTE 1.
R&D EXST UTIL POLE
PRIOR TO CONSTR
TREES AND/OR TREE STUMPS
TO BE REMOVED, 2105 SF
TREES AND/OR TREE STUMPS
TO BE REMOVED, 6835 SF
TREES AND/OR TREE STUMPS
TO BE REMOVED, 240 SF
R&D EXIST SD PIPES
W/IN CONSTR LIMITS
NORTH
LB-LINE
LB21+00
LB32+00
LB20+00
LB21+00
LB22+00
LB23+00
LB24+00
LB25+00
LB26+00
LB27+00
LB28+00
LB29+00
LB30+00
LB31+00
LB32+00
WELL 5, CONTRACTOR TO
VERIFY REMOVAL BY OTHERS
WITHIN LEVEE LIMITS
E
E
E
E
CORRALITOS CREEK
LB LEVEE LIMITS
LB CONSTR LIMITS
(FOLLOW PFCE ON LANDSIDE)
R&D EXIST SD PIPES W/IN
CONSTRUCTION LIMITS.
R&D EXIST SD PIPES,
W/IN CONSTR LIMITS
TREES AND/OR TREE STUMPS TO
BE REMOVED, 9970 SF
R&D EXST UTIL POLES, J-BOX,
SITE POST PRIOR TO CONSTR
TREES AND/OR TREE STUMPS TO
BE REMOVED, 6520 SF
NORTH
LB-LINE
WELL 4, CONTRACTOR TO
VERIFY REMOVAL BY OTHERS
WITHIN LEVEE LIMITS
EXST TEMP AG STRUCT, UNDG & AG PIPES,
FENCES AND APPURTENANCES. R&D TO BE
COMPLETED BY LANDOWNERS W/IN CONSTR
LIMITS PRIOR TO CONSTR, SEE NOTE 1.
LB43+00
LB32+00
LB33+00
LB34+00
LB35+00
LB36+00 LB37+00
LB38+00
LB39+00
LB40+00
LB41+00 LB42+00
LB43+00
SCALE IN FEET
40 0 8040
1" = 40'
PLAN STA LB21+00 TO LB32+00
1" = 40'
PLAN STA LB32+00 TO LB43+00
\\H
AL
EY
AL
D R
IC
H
.C O
M \S
H
AR
E\ G
R
AN
IT
E\
\2
0-
A3 G
EO
C
EG
JV
-P
AJ
AR
O
R
IV
ER
LE
VE
ER
EA
C
H
ES
6& 5\
AU
TO
C
AD
-R
EA
C H
6\
SH
EE
TS
\0
-0
-C
-D
EM
O
LI
TI
O
N -P
LA
N
-L B.
D W
G 6:
:0
PM
/4
/2
AE
C _B
&W .S
TB
EZ
AN
E
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
A3
GE
O -C
E& G
JV
Ÿ
Ba nc ro ft
W ay
, B er ke le y
CA
OF
D
ES
IG
N
F
IR
M
M
ATCH LINE
M
AT
C H
L
IN
E
ST
A:
L
B4 3+
SE
E
SH
EE
T C
-1 2)
M
AT
C H
L
IN
E M
AT
CH
L
IN
E
ST
A:
L
B2 1+
SE
E
SH
EE
T C-
SA
N
F R
AN
C
IS
C
O D
IS
TR
IC
T
G O
LD
EN
G
AT
E
AV
E.
, 4
TH
F
LO
O
R
SA
N F
R
AN
C
IS
C O
, C A
2-
W
2P
C
XX
JU
LY
AN
SI
D
W
2P
5B A0
SA
N
TA
C
R U
Z C
O U
N
TY
, C
AL
IF
O
R N
IA
PA
JA
R
O R
IV
ER
A T
W
AT
SO
N
VI
LL
E, C
A R
EA
C
H
SO
LI
C
IT
AT
IO
N
C-11
D
EM
O
LI
TI
O
N P
LA
N
LE
FT
B
AN
K
ST
A
LB
+0
TO
L B4
3+
E.
Z
AN
E
J.
B
U
ST
AM
AN
TE
J.
B
U
ST
AM
AN
TE
P.
G
R
EG
O R
Y
NOTES
1. BUILDING, APPURTENANCE, PUMP STATION/PIPES, UTILITY SERVICES, HOOP HOUSES/CROPS, WILL BE REMOVED OR RELOCATED BY OTHERS PER REAL ESTATE PURCHASE AGREEMENT. CONTRACTOR TO R&D AND C&G WHAT IS REMAINED ONSITE AFTER THE WORK BY
OTHERS IS COMPLETED. SEE NOTES 2 AND 3 FOR WORK TO BE COMPLETED BY CONTRACTOR.
2. CONTRACTOR SHALL R&D OF EXISTING STORM DRAIN PIPES, AC PAVEMENT, AND FENCES WITHIN THE CONSTRUCTION LIMITS.
CONTRACTOR SHALL ALSO RELOCATE, AS NECESSARY, ANY ACTIVE UTILITIES OR REMOVE ANY ABANDONED UTILITIES NOT IDENTIFIED ON
THE PLANS LOCATED WITHIN THE CONSTRUCTION LIMITS.
3. CONTRACTOR TO REMOVE TREE STUMPS. TREE SURVEY INCLUDED AS ATTACHMENT TO CONTRACT AMENDMENT.
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
JU
L
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
AU
G
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
PIPES
AutoCAD SHX Text
DENSE TREE
AutoCAD SHX Text
DENSE TREE
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
DENSE TREE
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
PIPE
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DENSE TREE
E
E E
E E
E E
E E
E E
E
CORRALITOS CREEK
PROTECT EXST
DRAINAGE DITCH
EXST TEMP AG STRUCT, UNDG & AG
PIPES, FENCES AND APPURTENANCES.
R&D TO BE COMPLETED BY
LANDOWNERS W/IN CONSTR LIMITS
PRIOR TO CONSTR, SEE NOTE 1
LB LEVEE LIMITS
C&G EXST TREES, TREE STUMPS
AND/OR SHRUBS, W/IN CONSTR LIMITS
PROTECT EXST TEMP AG STRUCT,
OUTSIDE CONSTR LIMITS
COORDINATE W/ PG&E SAFETY CLEARANCE WHEN WORKING
NEAR POWER TRANSMISSION LINES, OUTSIDE CONSTR LIMITS
RELOCATION OF EXST UTIL
BY OTHERS, TYP
CONSTR LIMITSLB CONSTR LIMITS
(FOLLOW PFCE ON LANDSIDE)
TREES AND/OR TREE STUMPS
TO BE REMOVED, 680 SF
TREES AND/OR TREE STUMPS
TO BE REMOVED, 11520 SF
TREES AND/OR TREE STUMPS
TO BE REMOVED, SEE ABOVE SF
TREES AND /OR TREE STUMPS TO BE
REMOVED, SEE PREVIOUS SHEET SF
TREES AND /OR TREE STUMPS TO BE
REMOVED, 6550 SF
NORTH
LB-LINE
EXST TEMP AG STRUCT, UNDG & AG PIPES,
FENCES AND APPURTENANCES. R&D TO BE
COMPLETED BY LANDOWNERS W/IN CONSTR
LIMITS PRIOR TO CONSTR, SEE NOTE 1
LB43+00
LB54+00
43+00
LB44+00 LB45+00 LB46+00
LB47+00
LB48+00
LB49+00
LB50+00
LB51+00
LB52+00
LB53+00
LB54+00
2C -69
TREES AND/OR TREE STUMPS
TO BE REMOVED, SEE ABOVE SF
TREES AND/OR TREE STUMPS
TO BE REMOVED, 31580 SF
C-69
HI-VIS TREE
PROTECTION DETAIL
NORTH
LB-LINE
EXST TEMP AG STRUCT, UNDG & AG PIPES,
FENCES AND APPURTENANCES. R&D TO BE
COMPLETED BY LANDOWNERS W/IN CONSTR
LIMITS PRIOR TO CONSTR, SEE NOTE 1
LB LEVEE LIMITS
LB54+00
LB55+00
LB56+00
LB57+00
LB58+00
C-69
HI-VIS TREE
PROTECTION DETAIL
CONSTR LIMITS
LB CONSTR LIMITS
(FOLLOW PFCE ON LANDSIDE)
R&D EXST SITE POSTS W/IN CONSTR
LIMITS PRIOR TO CONSTR, TYP
TREES AND/OR TREE STUMP
TO BE REMOVED, 9165 SFNORTH
LB-LINE
NORTH
EXST TEMP AG STRUCT, UNDG & AG PIPES,
FENCES AND APPURTENANCES. R&D TO BE
COMPLETED BY LANDOWNERS W/IN CONSTR
LIMITS PRIOR TO CONSTR, SEE NOTE 1
LB LEVEE LIMITS
LB57+00
LB58+00
LB59+00
LB60+00
LB61+00
SCALE IN FEET
40 0 8040
1" = 40'
PLAN STA LB43+00 TO LB54+00
1" = 40'
PLAN STA LB54+00 TO LB57+50
\\H
AL
EY
AL
D R
IC
H
.C O
M \S
H
AR
E\ G
R
AN
IT
E\
\2
0-
A3 G
EO
C
EG
JV
-P
AJ
AR
O
R
IV
ER
LE
VE
ER
EA
C
H
ES
6& 5\
AU
TO
C
AD
-R
EA
C H
6\
SH
EE
TS
\0
-0
-C
-D
EM
O
LI
TI
O
N -P
LA
N
-L B.
D W
G 6:
:1
PM
/4
/2
AE
C _B
&W .S
TB
EZ
AN
E
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
A3
GE
O -C
E& G
JV
Ÿ
Ba nc ro ft
W ay
, B er ke le y
CA
OF
D
ES
IG
N
F
IR
M
M
ATC
H
LIN
E
M
AT
C H
L
IN
E S
TA
: L
B6 1+
SE
E
SH
EE
T C
-1 3)
M
ATCH LINE STA: LB43+00 (SEE SHEET C-11)
M
ATC
H
LIN
E
1" = 40'
PLAN STA LB57+50 TO STA LB61+50
MAT
CH LI
NE
M
ATCH LINE
SA
N
F R
AN
C
IS
C
O D
IS
TR
IC
T
G O
LD
EN
G
AT
E
AV
E.
, 4
TH
F
LO
O
R
SA
N F
R
AN
C
IS
C O
, C A
2-
W
2P
C
XX
JU
LY
AN
SI
D
W
2P
5B A0
SA
N
TA
C
R U
Z C
O U
N
TY
, C
AL
IF
O
R N
IA
PA
JA
R
O R
IV
ER
A T
W
AT
SO
N
VI
LL
E, C
A R
EA
C
H
SO
LI
C
IT
AT
IO
N
C-12
D
EM
O
LI
TI
O
N P
LA
N
LE
FT
B
AN
K
ST
A
LB
+0
TO
L B6
1+
E.
Z
AN
E
J.
B
U
ST
AM
AN
TE
J.
B
U
ST
AM
AN
TE
P.
G
R
EG
O R
Y
NOTES
1. BUILDING, APPURTENANCE, PUMP STATION/PIPES, UTILITY SERVICES, HOOP HOUSES/CROPS, WILL BE REMOVED OR RELOCATED BY OTHERS PER REAL ESTATE PURCHASE AGREEMENT. CONTRACTOR TO R&D AND C&G WHAT IS REMAINED ONSITE AFTER THE WORK BY
OTHERS IS COMPLETED. SEE NOTES 2 AND 3 FOR WORK TO BE COMPLETED BY CONTRACTOR.
2. CONTRACTOR SHALL R&D OF EXISTING STORM DRAIN PIPES, AC PAVEMENT, AND FENCES WITHIN THE CONSTRUCTION LIMITS.
CONTRACTOR SHALL ALSO RELOCATE, AS NECESSARY, ANY ACTIVE UTILITIES OR REMOVE ANY ABANDONED UTILITIES NOT IDENTIFIED ON
THE PLANS LOCATED WITHIN THE CONSTRUCTION LIMITS.
3. CONTRACTOR TO REMOVE TREE STUMPS. TREE SURVEY INCLUDED AS ATTACHMENT TO CONTRACT AMENDMENT.
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
JU
L
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
AU
G
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
DENSE TREE
AutoCAD SHX Text
DENSE TREE
AutoCAD SHX Text
WOOD PILE
AutoCAD SHX Text
DP
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
CORRALITOS CREEK
AutoCAD SHX Text
DENSE TREE
AutoCAD SHX Text
DENSE TREE
AutoCAD SHX Text
CORRALITOS CREEK
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
DENSE TREE
AutoCAD SHX Text
DENSE TREE
AutoCAD SHX Text
CORRALITOS CREEK
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DENSE TREE
E E
E E
E E
E E
E E
E E
E E
CORRALITOS CREEK
LB LEVEE LIMITS
C&G TREES, TREE STUMPS AND/OR
SHRUBS, W/IN CONSTR LIMITS
LB CONSTR LIMITS
(FOLLOW PFCE ON LANDSIDE) R&D EXIST SD PIPES
W/IN CONSTR LIMITS
R&D EXIST WATER PIPES
W/IN CONSTR LIMITS
TREES AND/OR TREE STUMPS
TO BE REMOVED, 805 SF
TREES AND/OR TREE
STUMPS TO BE REMOVED,
SEE LEFT SF
TREES AND/OR TREE STUMPS TO
BE REMOVED, 1435 SF
NORTH
LB-LINE
EXST TEMP AG STRUCT, UNDG & AG
PIPES, FENCES AND
APPURTENANCES. R&D TO BE
COMPLETED BY LANDOWNERS W/IN
CONSTR LIMITS PRIOR TO CONSTR,
SEE NOTE 1
LB62+00 LB63+00 LB64+00 LB65+00 LB66+00 LB67+00
LB68+00
COMM
E
E
E
E
E
W W
W
PROTECT EXST WATER LINE
OUTSIDE CONSTR LIMITS
R&D EXIST WATER PIPES
W/IN CONSTR LIMITS
TREES AND/OR TREE
STUMPS TO BE REMOVED,
SEE LEFT SF
EXST TEMP AG STRUCT, UNDG & AG PIPES, FENCES AND
APPURTENANCES. R&D TO BE COMPLETED BY
LANDOWNERS W/IN CONSTR LIMITS PRIOR TO CONSTR, SEE
NOTE 1.
R&D EXST SITE POST PRIOR TO CONSTR
TREES AND/OR TREE STUMPS
TO BE REMOVED, 4190 SF
NORTH
CORRALITOS CREEK
LB-LINE
LB68+00
LB69+00
LB70+00
LB71+00
LB72+00
WELL 2, CONTRACTOR TO VERIFY REMOVAL BY
OTHERS WITHIN LEVEE LIMITS
NORTH
CORRALITOS CREEK
LB LEVEE LIMITS
LB CONSTR LIMITS
TREES AND/OR TREE STUMPS
TO BE REMOVED, 28815 SF
EXST TEMP AG STRUCT, UNDG & AG PIPES, FENCES AND
TREES AND/OR TREE STUMPS
TO BE REMOVED, 1730 SF
TREES AND/OR TREE STUMPS
TO BE REMOVED, 4190 SF
TREES AND/OR TREE STUMPS TO
BE REMOVED, SEE PREVIOUS SF
TREES AND/OR TREE STUMPS
TO BE REMOVED, 95 SF
LB CONSTR LIMITS
(FOLLOW PFCE ON LANDSIDE)
NORTH
LB-LINE
EXST TEMP AG STRUCT, UNDG & AG PIPES,
FENCES AND APPURTENANCES. R&D TO BE
COMPLETED BY LANDOWNERS W/IN CONSTR
LIMITS PRIOR TO CONSTR, SEE NOTE 1
LB72+00
LB73+00
LB74+00
LB75+00
LB76+00
LB77+00
LB78+00 LB79+00
LB80+00
ABANDON EXST WELL IN CONFORMANCE
W/ SANTA CRUZ COUNTY ENVIRONMENTAL
HEALTH REQUIREMENTS
ABANDON EXST WELL IN CONFORMANCE W/ SANTA CRUZ COUNTY
ENVIRONMENTAL HEALTH REQUIREMENTS
SCALE IN FEET
40 0 8040
\\H
AL
EY
AL
D R
IC
H
.C O
M \S
H
AR
E\ G
R
AN
IT
E\
\2
0-
A3 G
EO
C
EG
JV
-P
AJ
AR
O
R
IV
ER
LE
VE
ER
EA
C
H
ES
6& 5\
AU
TO
C
AD
-R
EA
C H
6\
SH
EE
TS
\0
-0
-C
-D
EM
O
LI
TI
O
N -P
LA
N
-L B.
D W
G 6:
:3
PM
/4
/2
AE
C _B
&W .S
TB
EZ
AN
E
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
A3
GE
O -C
E& G
JV
Ÿ
Ba nc ro ft
W ay
, B er ke le y
CA
OF
D
ES
IG
N
F
IR
M
M
ATC
H
LIN
E
1" = 40'
PLAN STA LB61+50 TO LB67+50
1" = 40'
PLAN STA LB72+50 TO STA LB80+50
M
ATC
H
LIN
E STA: LB80+50 (SEE SH
EET C
-14)
1" = 40'
PLAN STA LB67+50 TO LB72+50
M
ATC
H
LIN
E
M
AT
C H
L
IN
E
M
AT
C H
L
IN
E S
TA
: L
B6 1+
SE
E
SH
EE
T C
-1 2)
M
ATC
H
LIN
E
SA
N
F R
AN
C
IS
C
O D
IS
TR
IC
T
G O
LD
EN
G
AT
E
AV
E.
, 4
TH
F
LO
O
R
SA
N F
R
AN
C
IS
C O
, C A
2-
W
2P
C
XX
JU
LY
AN
SI
D
W
2P
5B A0
SA
N
TA
C
R U
Z C
O U
N
TY
, C
AL
IF
O
R N
IA
PA
JA
R
O R
IV
ER
A T
W
AT
SO
N
VI
LL
E, C
A R
EA
C
H
SO
LI
C
IT
AT
IO
N
C-13
D
EM
O
LI
TI
O
N P
LA
N
LE
FT
B
AN
K
ST
A
LB
+5
TO
L B8
0+
E.
Z
AN
E
J.
B
U
ST
AM
AN
TE
J.
B
U
ST
AM
AN
TE
P.
G
R
EG
O R
Y
NOTES
1. BUILDING, APPURTENANCE, PUMP STATION/PIPES, UTILITY SERVICES, HOOP HOUSES/CROPS, WILL BE REMOVED OR RELOCATED BY OTHERS PER REAL ESTATE PURCHASE AGREEMENT. CONTRACTOR TO R&D AND C&G WHAT IS REMAINED ONSITE AFTER THE WORK BY
OTHERS IS COMPLETED. SEE NOTES 2 AND 3 FOR WORK TO BE COMPLETED BY CONTRACTOR.
2. CONTRACTOR SHALL R&D OF EXISTING STORM DRAIN PIPES, AC PAVEMENT, AND FENCES WITHIN THE CONSTRUCTION LIMITS.
CONTRACTOR SHALL ALSO RELOCATE, AS NECESSARY, ANY ACTIVE UTILITIES OR REMOVE ANY ABANDONED UTILITIES NOT IDENTIFIED ON
THE PLANS LOCATED WITHIN THE CONSTRUCTION LIMITS.
3. CONTRACTOR TO REMOVE TREE STUMPS. TREE SURVEY INCLUDED AS ATTACHMENT TO CONTRACT AMENDMENT.
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
JU
L
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
AU
G
AutoCAD SHX Text
CORRALITOS CREEK
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DENSE TREE
AutoCAD SHX Text
DENSE TREE
AutoCAD SHX Text
PIPES
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
TANK
AutoCAD SHX Text
TANKS
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DENSE TREE
AutoCAD SHX Text
CULV
AutoCAD SHX Text
CORRALITOS CREEK
AutoCAD SHX Text
CORRALITOS CREEK
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DENSE TREE
G
REEN VALLEY RD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
W
W
W
W
W
W
W
W
W
W
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
MCO
M
M
COMM
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
E
E
E
E
E
E
E
E
E
E
E
E
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
CORRALITOS CREEK
PROTECT WATER LINE,
OUTSIDE CONSTR LIMITS
LB CONSTR LIMITS
(FOLLOW PFCE ON LANDSIDE)
LB CONSTR LIMITS
END LEFT BANK
LAYOUT LINE (LB-LINE)
R&D EXIST SD PIPES
W/IN CONSTR LIMITS,
PROTECT EXIST
DRAINAGE INLET
PROTECT EXST ASPHALT,
OUTSIDE CONSTR LIMITS
PROTECT SAN LINE,
OUTSIDE CONSTR LIMITS
PROTECT GAS LINE,
OUTSIDE CONSTR LIMITS
TREES AND/OR TREE STUMPS
TO BE REMOVED, 1200 SF
TREES AND/OR TREE STUMPS
TO BE REMOVED, 670 SF
R&D EXST FN
R&D EXST BLDG
TREES AND/OR TREE STUMPS
TO BE REMOVED, 310 SF
NORTH
NORTH
R&D EXST SIDEWALK, CURB, AND GUTTER
WITHIN LIMITS OF PROPOSED DRIVEWAY
R&D EXIST OUTFALL
STRUCTURE
LB87+00
LB92+85
LB87+00
LB88+00
LB89+00
LB90+00
LB91+00
LB92+00
SD
SD
SD
SD
SD
SD
SD
SD
SD
E E
E E
E E
E E
E E
E E
E E
E E
E E
E E
E
G
G
G G
GG
SD
SD
SD
CORRALITOS CREEK
PROTECT EXST PUMP STATION
LB LEVEE LIMITS
LB CONSTR LIMITS
(FOLLOW PFCE ON LANDSIDE)
LB CONSTRUCT LIMITS
LB CONSTR LIMITS
(FOLLOW PFCE ON LANDSIDE)
R&S EXST ASPHALT,
W/IN CONSTR LIMITS
PROTECT EXST UTIL,
OUTSIDE CONSTR LIMITS
R&D EXST FN
EXST ELECTRICAL UTIL WILL BE REMOVED
PRIOR TO CONSTR W/IN CONSTR LIMITS
R&D EXST BLDG
TREES AND/OR TREE STUMPS
TO BE REMOVED, 310 SF
TREES AND/OR TREE STUMPS
TO BE REMOVED, 3360 SF
TREES AND/OR TREE STUMPS TO
BE REMOVED, SEE PREVIOUS SF
NORTH
LB-LINE
EXST TEMP AG STRUCT, UNDG & AG PIPES,
FENCES AND APPURTENANCES. R&D TO BE
COMPLETED BY LANDOWNERS W/IN CONSTR
LIMITS PRIOR TO CONSTR, SEE NOTE 1
LB87+00
LB81+00 LB82+00
LB83+00
LB84+00
LB85+00
LB86+00
LB87+00
SCALE IN FEET
40 0 80401" = 40'
PLAN STA LB87+00 TO LB92+85
\\H
AL
EY
AL
D R
IC
H
.C O
M \S
H
AR
E\ G
R
AN
IT
E\
\2
0-
A3 G
EO
C
EG
JV
-P
AJ
AR
O
R
IV
ER
LE
VE
ER
EA
C
H
ES
6& 5\
AU
TO
C
AD
-R
EA
C H
6\
SH
EE
TS
\0
-0
-C
-D
EM
O
LI
TI
O
N -P
LA
N
-L B.
D W
G 6:
:1
PM
/4
/2
AE
C _B
&W .S
TB
EZ
AN
E
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
A3
GE
O -C
E& G
JV
Ÿ
Ba nc ro ft
W ay
, B er ke le y
CA
OF
D
ES
IG
N
F
IR
M
M
ATCH LINE
1" = 40'
PLAN STA LB80+50 TO LB87+00
M
ATC
H
LIN
E
M
AT
CH
L
IN
E
ST
A:
L B8
0+
SE
E
SH
EE
T
C-
SA
N
F R
AN
C
IS
C
O D
IS
TR
IC
T
G O
LD
EN
G
AT
E
AV
E.
, 4
TH
F
LO
O
R
SA
N F
R
AN
C
IS
C O
, C A
2-
W
2P
C
XX
JU
LY
AN
SI
D
W
2P
5B A0
SA
N
TA
C
R U
Z C
O U
N
TY
, C
AL
IF
O
R N
IA
PA
JA
R
O R
IV
ER
A T
W
AT
SO
N
VI
LL
E, C
A R
EA
C
H
SO
LI
C
IT
AT
IO
N
C-14
D
EM
O
LI
TI
O
N P
LA
N
LE
FT
B
AN
K
ST
A
LB
+5
TO
L B9
2+
E.
Z
AN
E
J.
B
U
ST
AM
AN
TE
J.
B
U
ST
AM
AN
TE
P.
G
R
EG
O R
Y
NOTES
1. BUILDING, APPURTENANCE, PUMP STATION/PIPES, UTILITY SERVICES, HOOP HOUSES/CROPS, WILL BE REMOVED OR RELOCATED BY OTHERS PER REAL ESTATE PURCHASE AGREEMENT. CONTRACTOR TO R&D AND C&G WHAT IS REMAINED ONSITE AFTER THE WORK BY
OTHERS IS COMPLETED. SEE NOTES 2 AND 3 FOR WORK TO BE COMPLETED BY CONTRACTOR.
2. CONTRACTOR SHALL R&D OF EXISTING STORM DRAIN PIPES, AC PAVEMENT, AND FENCES WITHIN THE CONSTRUCTION LIMITS.
CONTRACTOR SHALL ALSO RELOCATE, AS NECESSARY, ANY ACTIVE UTILITIES OR REMOVE ANY ABANDONED UTILITIES NOT IDENTIFIED ON
THE PLANS LOCATED WITHIN THE CONSTRUCTION LIMITS.
3. CONTRACTOR TO REMOVE TREE STUMPS. TREE SURVEY INCLUDED AS ATTACHMENT TO CONTRACT AMENDMENT.
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
JU
L
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
AU
G
AutoCAD SHX Text T
AutoCAD SHX Text
CULV
AutoCAD SHX Text
ASPH
AutoCAD SHX Text
ASPH
AutoCAD SHX Text
ASPH
AutoCAD SHX Text
ASPH
AutoCAD SHX Text
ASPH
AutoCAD SHX Text
GREEN VALLEY RD
AutoCAD SHX Text
CONC BRIDGE
AutoCAD SHX Text
ASPH
AutoCAD SHX Text
ASPH
AutoCAD SHX Text
CORRALITOS CREEK
AutoCAD SHX Text
CORRALITOS CREEK
AutoCAD SHX Text
CULTIVATED
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DENSE TREE
AutoCAD SHX Text
DENSE TREE
AutoCAD SHX Text
DENSE TREE
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text
GATE
AutoCAD SHX Text
CONC
AutoCAD SHX Text
CONC
AutoCAD SHX Text
DECK
AutoCAD SHX Text
DECK
AutoCAD SHX Text
DECK
AutoCAD SHX Text
ASPH
AutoCAD SHX Text
ASPH
AutoCAD SHX Text
ASPH
AutoCAD SHX Text
CORRALITOS CREEK
AutoCAD SHX Text
DIRT
AutoCAD SHX Text
DENSE TREE
LB52+00
LB52+50
N O
R
TH
X
X
X
X
X X
X X
X X
X
XXXXXXXX
X
C-68 TYP PANEL GATE
C-68 T-POST AND WIRE MESH FENCE
SDL-6-LINE
LB-LINE
CORRALITOS CREEK
PFCE
PFCE
PFCE
PFC
E
PFC
E
PFC
E
PFC
E
PFC
E
PFC
E
PFC
E
PFC
EPFCEPFCEPFCEPFCEPFCEPFCEPFCE
SDL61+80SDL60+00
SDL60+50
SDL61+00 SDL61+50
LB LIMITS OF GRADING
/CONSTR LIMITS (FOLLOW PFCE ON LANDSIDE)
LB LIMITS OF GRADING,
FOLLOW CONSTR LIMITS, WATERSIDE
GRADING CONFORM,
LIMITS OF RSP
GRADING CONFORM
S-01
DRAINAGE STRUCTURE W/
FLAP GATE 36" RCP
INV EL 83.63
S-01
DRAINAGE STRUCTURE
NO FLAP GATE
INV EL 84.71
-2.00%
-2.00%
C-67
STANDARD PIPE TRENCH
BEDDING AND WIDTH
FILTER
DIAPHGRAM
C-69
FILTER
DIAPHRAGM
S-02GATE WELL STRUCTURE
EL
EV
AT
IO
N (F
T)
EL
EV
AT
IO
N (F
T)
SDL60+00 SDL60+20 SDL60+40 SDL60+60 SDL60+80 SDL61+00 SDL61+20 SDL61+40 SDL61+60 SDL61+80
2% 2%
ST
A
+0
3.
EL
7.
ST
A
+4
2.
EL
2.
ST
A
+4
9.
EL
0.
ST
A
+7
8.
EL
4.
ST
A
+8
5.
EL
4.
STA 60+78.31
EL 82.10
STA 60+87.31
EL 82.10
ST
A
+4
7.
EL
1.
ST
A
+5
5.
EL
3.
ST
A
+6
0.
EL
3.
ST
A
+6
8.
EL
6.
STA 61+46.78
INV EL 84.71
STA 60+49.46
INV EL 83.73
LB-LINE
S=0.01S=0.01
ST
A
+1
5.
EL
8.
LANDSIDEWATERSIDE
STA 60+86.80
INV EL 84.10
STA 60+78.80
INV EL 84.02
2% 2%
S-01
DRAINAGE
STRUCTURE
W/ FLAP GATE
C-67
STANDARD PIPE TRENCH
BEDDING AND WIDTH1
S-02 GATE WELL STRUCTURE
36" RCP
36" RCP
25 AEPWS w/ A
2.5' THICK RSP,
EM-1601-5/CALTRANS CLASS III
9" BEDDING STONE
EG
ST
A
+1
1.
EL
1.
STA 61+14.55
EL 91.24
STA 61+11.57
EL 80.05
STA 61+14.57
EL 80.05
S-01
DRAINAGE
STRUCTURE
NO FLAP GATE
C-69 FILTER DIAPHRAGM
STA 61+22.10
EL 88.80
TOP OF LB LEVEE
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
A3
GE
O -C
E&
JV
Ÿ
Ba nc ro ft W ay , B er ke le y
CA
OF
D
ES
IG
N
F
IR
M
\\H
AL
EY
AL
D R
IC
H
.C O
M \S
H
AR
E\ G
R
AN
IT
E\
\2
0-
A3 G
EO
C
EG
JV
-P
AJ
AR
O
R
IV
ER
LE
VE
ER
EA
C
H
ES
6& 5\
AU
TO
C
AD
-R
EA
C H
6\
SH
EE
TS
\0
-0
-C
-P
LA
N -P
R O
FI
LE
-S D
-L B.
D W
G 7:
:3
PM
/4
/2
AE
C _B
&W .S
TB
EZ
AN
E
SA
N
F R
AN
C
IS
C
O D
IS
TR
IC
T
G O
LD
EN
G
AT
E
AV
E.
, 4
TH
F
LO
O
R
SA
N F
R
AN
C
IS
C O
, C A
2-
W
2P
C
XX
JU
LY
AN
SI
D
W
2P
5B A0
SA
N
TA
C
R U
Z C
O U
N
TY
, C
AL
IF
O
R N
IA
PA
JA
R
O R
IV
ER
A T
W
AT
SO
N
VI
LL
E, C
A R
EA
C
H
SO
LI
C
IT
AT
IO
N
P.
G
R
EG
O R
Y
E.
Z
AN
E
E.
Z
AN
E
P.
G
R
EG
O R
Y
C-42
PL
AN
A N
D P
R O
FI
LE
ST
O
R M
D R
AI
N
1" = 10'
PLAN - STORM DRAIN 6 (STA LB52+13.41)
1" = 10'
PROFILE - STORM DRAIN 6 (STA LB52+13.41)
SCALE IN FEET
10 0 2010
NOTES
1. STATIONING AND ELEVATIONS ARE SHOWN ALONG SDL-6 LINE.
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
AU
G
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD SDSD SD
LB
+5
LB
+0
SDL71+24.92SDL70+00
SDL70+50
SDL71+00
X X
X X
X X
X X
X X
SDL-7-LINE
NO
RTH
C-68
T-POST AND WIRE
MESH FENCE
C-67 FLOODWALL PENETRATION
C-45 TYP SECTION - FW
LB-LINE
3.
0:
3.
0:
1C O
R R
AL
IT
O S
C R
EE
K
PFC
E
PFC
E
PFC
E
PFC
E
PFC
E
PFC
E
PFC
E
PFC
E
PFC
E
PFC
E
LB LIMITS OF GRADING
/CONSTR LIMITS (FOLLOW PFCE ON LANDSIDE)
LB LIMITS OF GRADING,
FOLLOW CONSTR LIMITS, WATERSIDE
GRADING CONFORM,
LIMITS OF RSP
EXIST DI, VERIFY LOCATION
DURING CONSTR, REMOVE EXIST
18" RCP, REPLACE WITH NEW 24" RCP
24" RCP,
INV EL 100.13
S-01
DRAINAGE STRUCTURE W/
FLAP GATE 24" RCP
INV EL 99.794
-2.00%
-2.00%
C-67
STANDARD PIPE TRENCH
AND BEDDING WIDTH
EL
EV
AT
IO
N (F
T)
EL
EV
AT
IO
N (F
T)
SDL70+00 SDL70+20 SDL70+40 SDL70+60 SDL70+80 SDL71+00 SDL71+20 SDL71+30
S=0.01
LB-LINE
C-67
STANDARD PIPE TRENCH
BEDDING AND WIDTH
ST
A
+1
2.
EL
7.
ST
A
+7
5.
EL
9.
ST
A
+8
0.
EL
.2
STA 70+96.78
EL 99.13
STA 70+98.28
EL 99.13
ST
A
+9
6.
EL
.0
ST
A
+8
0.
IN
V
EL
9.
2%
LANDSIDEWATERSIDE
C-67 FW PENETRATION
2% 2%
24" RCP
S-01
DRAINAGE STRUCTURE
W/ FLAP GATE
S-03FW TYP SECTION
25 AEPWS w/ A
EXC, 2H:1V
2.5' THICK RSP,
EM-1601-5/CALTRANS CLASS III
9" BEDDING STONE
EG
ST
A
+8
9.
EL
9.
STA 71+02.28
EL 99.13
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
A3
GE
O -C
E&
JV
Ÿ
Ba nc ro ft W ay , B er ke le y
CA
OF
D
ES
IG
N
F
IR
M
\\H
AL
EY
AL
D R
IC
H
.C O
M \S
H
AR
E\ G
R
AN
IT
E\
\2
0-
A3 G
EO
C
EG
JV
-P
AJ
AR
O
R
IV
ER
LE
VE
ER
EA
C
H
ES
6& 5\
AU
TO
C
AD
-R
EA
C H
6\
SH
EE
TS
\0
-0
-C
-P
LA
N -P
R O
FI
LE
-S D
-L B.
D W
G 7:
:3
PM
/4
/2
AE
C _B
&W .S
TB
EZ
AN
E
SA
N
F R
AN
C
IS
C
O D
IS
TR
IC
T
G O
LD
EN
G
AT
E
AV
E.
, 4
TH
F
LO
O
R
SA
N F
R
AN
C
IS
C O
, C A
2-
W
2P
C
XX
JU
LY
AN
SI
D
W
2P
5B A0
SA
N
TA
C
R U
Z C
O U
N
TY
, C
AL
IF
O
R N
IA
PA
JA
R
O R
IV
ER
A T
W
AT
SO
N
VI
LL
E, C
A R
EA
C
H
SO
LI
C
IT
AT
IO
N
P.
G
R
EG
O R
Y
E.
Z
AN
E
E.
Z
AN
E
P.
G
R
EG
O R
Y
C-43
PL
AN
A N
D P
R O
FI
LE
ST
O
R M
D R
AI
N
1" = 10'
PLAN - STORM DRAIN 7 (STA LB88+78.90)
1" = 10'
PROFILE - STORM DRAIN 7 (STA LB88+78.90)
SCALE IN FEET
10 0 2010
NOTES
1. STATIONING AND ELEVATIONS ARE SHOWN ALONG SDL-7 LINE.
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
AU
G
| Sheets and Views |
| 021-023-C07-DEMOLITION-PLAN-RB-22 |
| Sheet 1 |
| 021-023-C07-DEMOLITION-PLAN-RB-21 |
| Sheet 1 |
| 021-023-C07-DEMOLITION-PLAN-RB-23 |
| Sheet 1 |
| 024-028-C10-DEMOLITION-PLAN-LB |
| 024-028-C10-DEMOLITION-PLAN-LB-24 |
| 024-028-C10-DEMOLITION-PLAN-LB-25 |
| 024-028-C10-DEMOLITION-PLAN-LB-26 |
| 024-028-C10-DEMOLITION-PLAN-LB-27 |
| 024-028-C10-DEMOLITION-PLAN-LB-28 |
| 052-057-C38-PLAN-PROFILE-SD-LB-56 |
| 56 |
| Sheet 1 |
| 052-057-C38-PLAN-PROFILE-SD-LB-57 |
| 57 |
| Sheet 1 |
File details come from the government source that posted it. Updated .