02_TL_5.4.3_Fire_Supp_(Wet_Pipe)_(13_JUL_16).xlsx

XLSX spreadsheet 55 KB Posted

Attached to
Facilities Maintenance Services at Fort McCoy, WI
Solicitation number
W912ES-17-R-0002
Issued by

About this file

02 TL 5.4.3

View the file

Other files

File Type Posted
Amendment_3_.pdf PDF
02_TL_54_PM_Task_and_Freq_Chart_(18_Nov_16).xls XLS spreadsheet
Equipment_List_12-1-16.xlsx XLSX spreadsheet
BUILDING_LIST___21NOV16.xlsx XLSX spreadsheet
Amendment_2_.pdf PDF
01_TE_1.4.3_Workload_Data_(14_Nov_16).xlsx XLSX spreadsheet
01_TE_3-1_GFE_(29JAN2016).xlsx XLSX spreadsheet
02_TL_5_4_PM_Task_and_Freq_Chart_.xls XLS spreadsheet
Amendment_1_.pdf PDF
Site_Visit_Sign_In_Sheet_.pdf PDF
02_TL_5.4.4_Fire_Supp_(Dry_Pipe)_(18_FEB_16).xlsx XLSX spreadsheet
02_TL_4.7_WI_SALES_TAX_EXEMPT_FORM_.pdf PDF
02_TL_5.4.9_Cathodic_Protection_Testing.pdf PDF
02_TL_5.3.18b__Facility_Deactivation_(16AUG16).docx DOCX document
01_TE_3.2_GFF_(Post_B2108_Renovation).xlsx XLSX spreadsheet
MCC_Form_451.xlsx XLSX spreadsheet
00_PRS_Schedule_(7SEP16).xlsx XLSX spreadsheet
02_TL_5.4.1_Fire_Supp_(Ansul-Chemical).xlsx XLSX spreadsheet
Questionnaire_Attachment_.pdf PDF
01_CBA_FMC_2014-2017.pdf PDF
02_TL_5.4.5_Fire_Alarm_System.docx DOCX document
01_TE_1.4.3_Workload_Data_(31OCT16)_.xlsx XLSX spreadsheet
01_TE_3.2__GFF_(27_Oct_16).doc DOC document
02_TL_5.3.17Generator_Log_9-20-2016.xlsx XLSX spreadsheet
02_TL_1.2_3rd_Qtr_FY16.xlsx XLSX spreadsheet
02_TL_5.5_Ice_Melt_Report.xls XLS spreadsheet
Solicitation_.pdf PDF
01_TE_1.6.5_PRS_Description_FM_(18_Jul_16).doc DOC document
02_TL_5.4_PM_Task_and_Freq_Chart_(27_Oct_16).xls XLS spreadsheet
02_TL_5.4.6_Elevators_and_Lifts_(13_JUL_16).xlsx XLSX spreadsheet
02_TL_5.4.7_Water_System.pdf PDF
AR_420_1.pdf PDF
01_TE_3.3_GFP_Automation_(6SEP16).xlsx XLSX spreadsheet
01_TE_1.3_DSL_FM_(27_Oct_16).xlsx XLSX spreadsheet
FAC_MAINT_SCA-CBA_Employees.xlsx XLSX spreadsheet
01_TE_1.4.3_Workload_Table_(24_OCT_16).xls XLS spreadsheet
02_TL_5.4.2_Fire_Supp_(Kitchen_Hood_Cleaning).docx DOCX document
02_TL_1.6.12_HVAC_Qualifier.pdf PDF
02_TL_1.6_DD254_Contract_Security_Class_Spec.pdf PDF
02_TL_5.3.5_Facility_Standards.docx DOCX document
02_TL_5.3.18a_Facility_Activation_(16AUG16).docx DOCX document
02_TL_4.5b_Gen_tank_insp_Form_372.xlsx XLSX spreadsheet
02_TL_5.4.8_Earth_Bond_Testing.pdf PDF
02_TL_4.5a_TR-WM-118.pdf PDF
Show all 44

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WET Sprinkler Systems

DIRECTORATE OF PUBLIC WORKS (DPW) - FACILITY MAINTENANCE & REPAIR
TL 5-4.5 FIRE SUPPRESSION (WET PIPE)
SPRINKLER SYSTEMS (Wet Pipe)
NFPA 25, 2011 Edition
ITEMMONTHLY
PassFail
Pump Operation (no flow condition) B60, B495, B6062 (2-diesel, 2-electric)00
ITEMQUARTERLY
INSPECTIONPassFail
Control Valves00

Hydraulic Nameplates 0 0

Gauges (proper water pressure) 0 0

Fire Department Connections 0 0

Alarm Devices 0 0

Fire Pump Controller and Components B60, B495, B6062 (2-diesel, 2-electric)00
ITEMANNUALLY
INSPECTIONPassFail
Hangers/Seismic (all systems)00

Visible Piping 0 0

Sprinklers/ spare sprinkler heads /wrench 0 0

TEST
Alarm Devices00

Main Drain 0 0

Valves (all types) 0 0

Antifreeze Solution 0 0

Fire Pumps B60, B495, B6062 (2-diesel, 2-electric) 0 0

ITEM5 YEARS
TESTPassFail
All Gauges for Calibration00

Obstruction Investigation 0 0

ITEM10+ YEARS
TESTPassFail

Sprinklers Heads 0 0

Monthly

DIRECTORATE OF PUBLIC WORKS (DPW) - FACILITY MAINTENANCE & REPAIR
TL 5.4.3 FIRE SUPPRESSION (WET PIPE) - MONTHLY
TaskPump Operation (no flow condition) B60, B495, B6062 (2-diesel, 2-electric)
CriteriaPass = Electric pumps start, run for 10 Min with no leaks or malfunctions, Diesel pump engines start, run for 30 min, check all fluid levels (see notes), no leaks or malfunctions

Fail = Submit discrepancy to Govt Work Reception Ctr

BUILDINGPassFailS O #
SPRINK-W-60-01

*Firepump-60-01 (diesel)

SPRINK-W-495-01

Firepump-495-01 (elect)

SPRINK-W-6058-01
**Firepump-6062-01 (elect)
**Firepump-6062-02 (diesel)
**Firepump-6062-03 (diesel)
**Firepump-6062-04 (elect)
*Firepump is in Bldg. 61 and serves Bldg. 60.
** Firepumps are in Bldg. 6062 and serve Bldg. 6050 and Bldg. 6058.
NOTES FOR DIESEL PUMPS:
If fluid levels are low submit work order to IMMA.
Complete Operating Log attached to engine.
Check air intake and exhaust louvers for proper operation.
Fuel level should not be below 80%.
Check tag or log to ensure that required service has been performed on engine.
NOTES FOR ALL PUMPS:
Ensure all areas are clean and safe.
Complete and sign maintenance tags upon completion.

Quarterly

DIRECTORATE OF PUBLIC WORKS (DPW) - FACILITY MAINTENANCE & REPAIR
TL 5.4.3 FIRE SUPPRESSION (WET PIPE) - QUARTERLY
TaskControl ValvesVisually Inspect - Hydraulic NameplateCheck for proper water pressureFire Department ConnectionsAlarm Devices (water flow alarms, low pressure alarm)Fire Pump Controller and Components B60, B495, B6062 (2-diesel, 2-electric)
CriteriaPass = All valves in appropriate position, not leaking, free of defects

Fail = Submit discrepancy to Govt Work Reception Ctr

Pass = Is Present; Fail = Not Present
Fail = Submit discrepancy to Govt Work Reception CtrPass = Appropriate lbs of water pressure
Fail = Submit discrepancy to Govt Work Reception CtrPass = Visible and accessible, undamaged, caps in place, gasket is good, check valve not leaking
Fail = Submit discrepancy to Govt Work Reception CtrPass = Free from any physical damage, test per manufacturer instructions
Fail = Submit discrepancy to Govt Work Reception CtrPass = Controllers operate as required to start pumps

Fail = Submit discrepancy to Govt Work Reception Ctr

BUILDINGPassFailS O #PassFailS O #PassFailS O #PassFailS O #PassFailS O #PassFailS O #
SPRINK-W-60-01

*Firepump-60-01 (diesel)

SPRINK-W-90-01
SPRINK-W-200-01
SPRINK-W-200-02
SPRINK-W-200-03
SPRINK-W-200-04
SPRINK-W-200-05
SPRINK-W-207-01
SPRINK-W-220-01
SPRINK-W-490-01
SPRINK-W-495-01

Firepump-495-01 (elect)

SPRINK-W-1027-01
SPRINK-W-1213-01
SPRINK-W-1268-01
SPRINK-W-1361-01
SPRINK-W-1363-01
SPRINK-W-1364-01
SPRINK-W-1364-02
SPRINK-W-1370-01
SPRINK-W-1538-01
SPRINK-W-1564-01
SPRINK-W-1571-01
SPRINK-W-1747-01
SPRINK-W-1751-01
SPRINK-W-1796-01
SPRINK-W-2187-01
SPRINK-W-2195-01
SPRINK-W-2218-01
SPRINK-W-2442-01
SPRINK-W-2674-01
SPRINK-W-2858-01
SPRINK-W-2958-01
SPRINK-W-6050-01
SPRINK-W-6055-01
SPRINK-W-6058-01
**Firepump-6062-01 (elect)
**Firepump-6062-02 (diesel)
**Firepump-6062-03 (diesel)
**Firepump-6062-04 (elect)
SPRINK-W-9005-01
SPRINK-W-10000A-01
*Firepump is in Bldg. 61 and serves Bldg. 60.
** Firepumps are in Bldg. 6062 and serve Bldg. 6050 and Bldg. 6058.

Annual

DIRECTORATE OF PUBLIC WORKS (DPW) - FACILITY MAINTENANCE & REPAIR
TL 5.4.3 FIRE SUPPRESSION (WET PIPE) - ANNUAL
TaskHangers/Seismic (all systems)Visible PipingSprinklers/spare sprinkler heads /wrenchAlarm Devices(TEST)
Main Drain(TEST)
Valves (all types)(TEST)
Antifreeze Solution(TEST)

Fire Pumps B60, B495, B6062 (2-diesel, 2-electric)

CriteriaPass = No visible damage to hangers
Fail = Submit discrepancy to Govt Work Reception CtrPass = No visible damage to piping and associated hardware
Fail = Submit discrepancy to Govt Work Reception CtrPass = No damage to installed sprinkler heads, proper spare sprinkler heads and wrench are available
Fail = Submit discrepancy to Govt Work Reception CtrPass = Alarms operate at test, no physical damage
Fail = Submit discrepancy to Govt Work Reception CtrPass = Test annually to determine if there has been a change in the condition of the water supply piping and control valves.
Fail = Submit discrepancy to Govt Work Reception CtrPass = All valves shall be opened until torsion is felt in the rod, indicating that the rod has not separated from the valve
Fail = Submit discrepancy to Govt Work Reception CtrPass = Antifreeze solution is good to 30 below Zero
Fail = Submit discrepancy to Govt Work Reception CtrPass = Correct Total Pump Output for the rated capacity on each pump

Fail = Submit discrepancy to Govt Work Reception Ctr

PassFailS O #PassFailS O #PassFailS O #PassFailS O #PassFailS O #PassFailS O #PassFailS O #PassFailS O #
SPRINK-W-60-01

*Firepump-60-01 (diesel)

SPRINK-W-200-01
SPRINK-W-200-02
SPRINK-W-200-03
SPRINK-W-200-04
SPRINK-W-200-05
SPRINK-W-207-01
SPRINK-W-220-01
SPRINK-W-490-01
SPRINK-W-495-01

Firepump-495-01 (elect)

SPRINK-W-1027-01
SPRINK-W-1213-01
SPRINK-W-1268-01
SPRINK-W-1361-01
SPRINK-W-1363-01
SPRINK-W-1364-01
SPRINK-W-1364-02
SPRINK-W-1370-01
SPRINK-W-1538-01
SPRINK-W-1564-01
SPRINK-W-1571-01
SPRINK-W-1747-01
SPRINK-W-1751-01
SPRINK-W-1796-01
SPRINK-W-2187-01
SPRINK-W-2195-01
SPRINK-W-2218-01
SPRINK-W-2442-01
SPRINK-W-2674-01
SPRINK-W-2858-01
SPRINK-W-2958-01
SPRINK-W-3014-01
SPRINK-W-3049-01
SPRINK-W-6050-01
SPRINK-W-6055-01
SPRINK-W-6058-01
FP-3014-01 (elect)
FP-6062-01 (elect)
FP-6062-02 (diesel)
FP-6062-03 (diesel)
FP-6062-04 (elect)
SPRINK-W-9005-01
SPRINK-W-10000A-01
*Firepump is in Bldg. 61 and serves Bldg 60.
** Firepumps are in Bldg. 6062 and serve Bldg. 6050 and Bldg. 6058.

3 years

DIRECTORATE OF PUBLIC WORKS (DPW) - FACILITY MAINTENANCE & REPAIR
TL 5.4.3 FIRE SUPPRESSION (WET PIPE) - 3 YEARS
TASKFull Flow Trip
CriteriaPass = All parts are functioning properly and water flows at test station

Fail = Submit discrepancy to Govt Work Reception Ctr

BUILDINGPassFailS O #
SPRINK-W-60-01
SPRINK-W-200-01
SPRINK-W-200-02
SPRINK-W-200-03
SPRINK-W-200-04
SPRINK-W-200-05
SPRINK-W-207-01
SPRINK-W-220-01
SPRINK-W-490-01
SPRINK-W-495-01
SPRINK-W-1027-01
SPRINK-W-1213-01
SPRINK-W-1268-01
SPRINK-W-1361-01
SPRINK-W-1363-01
SPRINK-W-1364-01
SPRINK-W-1364-02
SPRINK-W-1370-01
SPRINK-W-1538-01
SPRINK-W-1564-01
SPRINK-W-1571-01
SPRINK-W-1747-01
SPRINK-W-1751-01
SPRINK-W-1796-01
SPRINK-W-2187-01
SPRINK-W-2195-01
SPRINK-W-2218-01
SPRINK-W-2442-01
SPRINK-W-2674-01
SPRINK-W-2858-01
SPRINK-W-2958-01
SPRINK-W-6050-01
SPRINK-W-6055-01
SPRINK-W-6058-01
SPRINK-W-9005-01
SPRINK-W-10000A-01

5 Years

DIRECTORATE OF PUBLIC WORKS (DPW) - FACILITY MAINTENANCE & REPAIR
TL 5.4.3 FIRE SUPPRESSION (WET PIPE) - 5 YEARS
TaskAll Gauges for CalibrationObstruction, Internal Inspection of Piping
CriteriaPass = All gauges are calibrated or replaced as needed
Fail = Submit discrepancy to Govt Work Reception CtrPass = Piping and branch line conditions are free of obstructions, organic and inorganic material

Fail = Submit discrepancy to Govt Work Reception Ctr

BUILDINGPassFailS O #PassFailS O #
SPRINK-W-51-01
SPRINK-W-60-01
SPRINK-W-90-01
SPRINK-W-200-01
SPRINK-W-200-02
SPRINK-W-200-03
SPRINK-W-200-04
SPRINK-W-200-05
SPRINK-W-207-01
SPRINK-W-220-01
SPRINK-W-490-01
SPRINK-W-60-01
SPRINK-W-200-01
SPRINK-W-200-02
SPRINK-W-200-03
SPRINK-W-200-04
SPRINK-W-200-05
SPRINK-W-207-01
SPRINK-W-220-01
SPRINK-W-490-01
SPRINK-W-495-01
SPRINK-W-1027-01
SPRINK-W-1213-01
SPRINK-W-1268-01
SPRINK-W-1361-01
SPRINK-W-1363-01
SPRINK-W-1364-01
SPRINK-W-1364-02
SPRINK-W-1370-01
SPRINK-W-1538-01
SPRINK-W-1564-01
SPRINK-W-1571-01
SPRINK-W-1747-01
SPRINK-W-1751-01
SPRINK-W-1796-01
SPRINK-W-2187-01
SPRINK-W-2195-01
SPRINK-W-2218-01
SPRINK-W-2442-01
SPRINK-W-2674-01
SPRINK-W-2858-01
SPRINK-W-2958-01
SPRINK-W-6050-01
SPRINK-W-6055-01
SPRINK-W-6058-01
SPRINK-W-9005-01
SPRINK-W-10000A-01

10+ Years

DIRECTORATE OF PUBLIC WORKS (DPW) - FACILITY MAINTENANCE & REPAIR
TL 5.4.3 FIRE SUPPRESSION (WET PIPE) - 10+ YEARS
TaskSprinkler Heads
CriteriaPass = sprinkler heads are replaced or representative samples are tested

Fail = Submit discrepancy to Govt Work Reception Ctr

BUILDINGPassFailS O #
SPRINK-W-60-01
SPRINK-W-200-01
SPRINK-W-200-02
SPRINK-W-200-03
SPRINK-W-200-04
SPRINK-W-200-05
SPRINK-W-207-01
SPRINK-W-220-01
SPRINK-W-490-01
SPRINK-W-495-01
SPRINK-W-1027-01
SPRINK-W-1213-01
SPRINK-W-1268-01
SPRINK-W-1361-01
SPRINK-W-1363-01
SPRINK-W-1364-01
SPRINK-W-1364-02
SPRINK-W-1370-01
SPRINK-W-1538-01
SPRINK-W-1564-01
SPRINK-W-1571-01
SPRINK-W-1747-01
SPRINK-W-1751-01
SPRINK-W-1796-01
SPRINK-W-2187-01
SPRINK-W-2195-01
SPRINK-W-2218-01
SPRINK-W-2442-01
SPRINK-W-2674-01
SPRINK-W-2858-01
SPRINK-W-2958-01
SPRINK-W-6050-01
SPRINK-W-6055-01
SPRINK-W-6058-01
SPRINK-W-9005-01
SPRINK-W-10000A-01