DRAFT_443309_-_VOLUME_4_03-31-16.pdf
PDF 6 MB Posted
- Attached to
- Kuwait Air Defense Improvements Federal contract opportunity
- Solicitation number
- W912ER-16-R-0008
About this file
Volume 4
View the file
Other files for this federal contract opportunity
Show all 50
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET ID
1/
/2
1:
:0
P
M
MIDDLE EAST DISTRICT
AIR DEFENSE IMPROVEMENTS
W912ER-16-R-0008
P2-443309
UNSPECIFIED WORLDWIDE
G-003
VOLUME 4 OF 4
STANDARDS
443309$ - STANDARDS
DRAFT
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5 1/
/2
1:
:0
P M
1/
/2
1:
:0
PM
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
Enter District
EM
S
G W
D
R O
B
ER
T L.
F O
X , P
E
-G
I0
G N
G-004
JA
R
IN
D
EX
O
F
VO
LU
M
ES
P2 -4
U
N
SP
E C
IF
IE
D
W O
R L D
W
ID
E
G
EN
ER
A
L
SHT. REF.
NO. FILE NO
REVISIONS
REV. NO. AM/COP NO. TITLE
INDEX OF VOLUMES
G-011
COVER SHEET VOLUME 1 OF 4
G-004
G-000 450031-GI000GN
VOLUME 1 SITE ICC#3
INDEX OF VOLUMES
INDEX OF DRAWINGS VOLUME 1 SHEET 1
SITE DESIGN - ICC #3
450031-GI004GN
450031-GI011GN
G-014
COVER SHEET VOLUME 3 OF 4
G-004
G-002 450031-GI002GN
VOLUME 3 SITE 07 - ALS
INDEX OF VOLUMES
INDEX OF DRAWINGS VOLUME 3 SHEET 1
450031-GI004GN
450031-GI015GN
SITE DESIGN - SITE 06 - ALJ
443309A - ENGAGEMENT CONTROL STATION
443309C - TOILET BUILDING
443309D – GUARD HOUSE
443309E – GUARD TOWER
443309F – CAR PARKING SHELTER
443309H – STORAGE FACILITY
443309I – FREQUENCY CONVERTER – PDU SHELTER
443309B - HEADQUARTERS BUILDING
443309G – TRUCK PARKING SHELTER
G-016
COVER SHEET VOLUME 4 OF 4
G-004
G-003 450031-GI003GN
VOLUME 4 STANDARDS
INDEX OF VOLUMES
INDEX OF DRAWINGS VOLUME 4 SHEET 1
450031-GI004GN
450031-GI017GN
443309$ - STANDARDS
G-012
COVER SHEET VOLUME 2 OF 4
G-004
G-001 450031-GI001GN
VOLUME 2 SITE 06 - ALJ
INDEX OF VOLUMES
INDEX OF DRAWINGS VOLUME 2 SHEET 1
450031-GI004GN
450031-GI013GN
G-013 INDEX OF DRAWINGS VOLUME 2 SHEET 2450031-GI014GN
G-015 INDEX OF DRAWINGS VOLUME 3 SHEET 2450031-GI016GN
443309K – SCREEN ROOM BUILDING
443309L – POWER PLANT FACILITY
443309M – PRAYER BUILDING
443309P – MAINTENANCE HIGH BAY
SITE DESIGN - SITE 07 - ALS
443309A - ENGAGEMENT CONTROL STATION
443309C - TOILET BUILDING
443309D – GUARD HOUSE
443309E – GUARD TOWER
443309F – CAR PARKING SHELTER
443309H – STORAGE FACILITY
443309I – FREQUENCY CONVERTER – PDU SHELTER
443309B - HEADQUARTERS BUILDING
443309G – TRUCK PARKING SHELTER
443309L – POWER PLANT FACILITY
443309M – PRAYER BUILDING
443309N – FUEL DISPENSING SUNSHADE
443309P – MAINTENANCE HIGH BAY
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
443309N2 – FUEL TRUCK PARKING SUNSHADE
443309N – FUEL DISPENSING SUNSHADE
443309N2 – FUEL TRUCK PARKING SUNSHADE
443309O – EQUIPMENT PADS
443309O – EQUIPMENT PADSDRAFT
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
B
C
D
2 3 4 5 1/
/2
1:
:5
P M
1/
/2
1:
:5
PM
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
Enter District
EM
S
G W
D
R O
B
ER
T L.
F O
X , P
E
-G
I0
G N
G-016
JA
R
IN
D
EX
O
F
DR
A W
IN
G
S
VO
LU
M
E
SH
EE
T
P2 -4
U
N
SP
E C
IF
IE
D
W O
R L D
W
ID
E
G
EN
ER
A
L
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
INDEX OF DRAWINGS
GENERAL VOLUME 4
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
GENERAL
G-003 450031-GI003GN COVER SHEET VOLUME 4 OF 4
G-004 450031-GI004GN INDEX OF VOLUMES
G-016 443309-GI016GN INDEX OF DRAWINGS VOLUME 4 SHEET 1
G-021 443309-GI021GN STANDARD LEGENDS AND SYMBOLOGY
G-031 443309-GI031GN STANDARD ABBREVIATIONS
443309$ - STANDARDS
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
PLUMBING
SP-001 443309$-MP001GN GENERAL NOTES, ABBREVIATIONS AND SYMBOLS
SP-501 443309$-MP501DT PLUMBING DETAILS
SP-502 443309$-MP502DT PLUMBING DETAILS
MECHANICAL
SM-001 443309$-MH001GN GENERAL NOTES, ABBREVIATIONS AND SYMBOLS
SM-002 450031$-SM002GN SEQUENCE OF OPERATIONS
SM-003 450031$-SM003GN SEQUENCE OF OPERATIONS
SM-501 450031$-SM501DT MECHANICAL DETAILS
SM-502 450031$-SM502DT MECHANICAL DETAILS
SM-503 450031$-SM503DT MECHANICAL DETAILS
SM-504 450031$-SM504DT MECHANICAL DETAILS
SM-601 443309$-SM601SC HVAC REGISTER SCHEDULES
ELECTRICAL
SE-001 443309$-SE001GN ELECTRICAL LEGEND, ABBREVIATIONS, SYMBOLS AND
GENERAL NOTES
SE-501 443309$-SE501DT ELECTRICAL DETAILS
SE-502 443309$-SE502DT GROUNDING AND OTHER DETAILS
SE-503 443309$-SE503DT LIGHTNING PROTECTION DETAILS
SE-504 443309$-SE505DT LIGHTING DETAILS
SE-505 443309$-SE506DT LIGHTING DETAILS
SE-506 443309$-SE507DT LIGHTING DETAILS & SCHEDULE
SE-601 443309$-SE601DI ELECTRONIC SECURITY SYSTEM ( ESS) RISER
DIAGRAM
TELECOMMUNICATIONS
ST-001 443309$-ST001GN COMMUNICATION STANDARDS LEGEND
ST-501 443309$-ST501DT COMMUNICATION DETAILS
ST-502 443309$-ST502DT COMMUNICATION DETAILS
ST-503 443309$-ST503DT COMMUNICATION DETAILS
ST-504 443309$-ST504DT COMMUNICATION DETAILS
ST-505 443309$-ST505DT COMMUNICATION DETAILS - PDS
ST-506 443309$-ST506DT COMMUNICATION DETAILS
ST-507 443309$-ST507DT COMMUNICATION DETAILS
443309$ - STANDARDS
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
SS-001 443309$-SS001GN GENERAL NOTES
SS-002 443309$-SS002GN CONCRETE NOTES
SS-003 443309$-SS003GN MASONRY NOTES
SS-004 443309$-SS004GN STRUCTURAL STEEL AND METAL BUILDING SYSTEM
NOTES
SS-501 443309$-SS501DT SLAB-ON-GRADE DETAILS
SS-502 443309$-SS502DT CONCRETE FOUNDATION DETAILS
SS-503 443309$-SS503DT CONCRETE BEAM DETAILS
SS-504 443309$-SS504DT CONCRETE COLUMN DETAILS
SS-505 443309$-SS505DT CONCRETE ELEVATED SLAB DETAILS
SS-506 443309$-SA506DT CONCRETE WALL DETAILS
SS-507 443309$-SS508DT MISCELLANEOUS CONCRETE DETAILS
SS-508 443309$-SS508DT MISCELLANEOUS CONCRETE DETAILS
SS-509 443309$-SS509DT MASONRY WALL DETAILS
SS-510 443309$-SS510DT MASONRY DETAILS
SS-511 443309$-SS511DT MBS FOUNDATION DETAILS
SS-512 443309$-SS512DT METAL BUILDING SYSYTEM DETAILS
SS-513 443309$-SS513DT SANITARY SEWER HOLDING TANK SECTIONS
ARCHITECTURAL
SA-001 443309$-SA001GN ARCHITECTURAL SYMBOLS & ABBREVIATIONS
SA-501 443309$-SA501DT WALL TYPES
SA-502 443309$-SA502DT COLUMN DETAILS
SA-503 443309$-SA503DT PARAPET DETAILS
SA-504 443309$-SA504DT METAL ROOF DETAILS
SA-505 443309$-SA505DT STAIR DETAILS
SA-506 443309$-SA506DT WINDOW AND DOOR TYPES
SA-506A 443309$-SA506ADT WINDOW TYPES AND DETAILS
SA-507 443309$-SA507DT WINDOW AND LOUVER DETAILS
SA-508 443309$-SA508DT DOOR DETAILS
SA-509 443309$-SA509DT OVERHEAD DOOR DETAILS
SA-510 443309$-SA510DT CEILING DETAILS
SA-511 443309$-SA511DT CASEWORK
SA-512 443309$-SA512DT CASEWORK DETAILS
SA-513 443309$-SA513DT CAGED LADDER DETAILS
SA-514 443309$-SA514DT ROOF DETAILS
SA-515 443309$-SA515DT MISC. DETAILS
SA-516 443309$-SA516DT SURFACE FINISHES AND DETAILS
SA-517 443309$-SA517DT FIXTURE HEIGHTS
SA-518 443309$-SA518DT INTERIOR SIGNAGE AND FINISH LEGEND
SA-519 443309$-SA519DT TYPICAL EXTERIOR WALL SECTIONS
SA-520 443309$-SA520DT MISC. DETAILS DRAFT
DRAWING AREA
TITLE TEXT SIZE
ISSUE BLOCK ONLY
SHEET ID BLOCK
6MM FOR SUBTITLES AND TITLES
3MM FOR DIMENSIONS, NOTES, CALLOUTS,
TABLE/SCHEDULE TEXT AND GENERAL TEXT
NOTE TEXT SIZE
A
AMENDMENT NUMBER
COP LETTER
MMDDYY
MMDDYY
MMDDYY
MMDDYY
2.5MM FOR REVISION TEXT
2.5MM FOR ISSUE TEXT
XX%
10%
DESIGN SUBMITTAL
BORDER SUBMITTAL
SHEET ID
X-101
SHEET OF
3MM SHEET ID TEXT
3MM FACILITY DESIGNATOR TEXT
5MM SHEET NUMBER TEXT
3MM VARAIBLE TEXT
1.5MM CONSTANT TEXT
SYMBOLS
GENERAL REFERENCE
CL
TEXT ATTRIBUTES
Ø
PL
X
X-XXX
X
X-XXX
X
X-XXX
X
X-XXX
PLAN NORTH
XXX
W1
1t
ROUGH FLOOR ELEVATION
IN PLAN
FINISH FLOOR ELEVATION
IN PLAN
ELEVATION SYMBOL IN
SECTION AND ELEVATION
COLUMN GRIDLINE
CENTERLINE ID
PLUS OR MINUS
DIAMETER
ELEVATION MARKER
PLATE LINE ID
ANGLE
PLUS
KEY PLAN HATCHING
KEY PLAN ID
RGH FL ELEV
FIN FL ELEV
FIN FL ELEV
NORTH SYMBOL
ROOM ID
DOOR ID
WINDOW ID
WALL TYPE ID
COLUMN ID - VERTICAL;
(USE NUMBERS)
COLUMN ID - HORIZONTAL;
(USE LETTERS EXCEPT
FOR O & I)
REVISION ID
EQUIPMENT ID
KEY NOTE ID
MATCHLINE IDMATCH LINE
SEE XX/X-XXX
View Scale
View Name X
X View Name View ScaleX-XXX
X View Name View ScaleX-XXX
DRAWING TITLE FOR PLANS,
DIAGRAMS, SCHEDULES,
3D REPRESENTATIONS,
OR STANDARD DETAILS
STANDARD DETAILS DO NOT
SPECIFICALLY REFERENCE A SHEET
STANDARD DETAILS ARE LOCATED
IN THE STANDARD NOTES AND DETAILS FOLDER
SECTION/ELEVATION LETTER,
OR DETAIL NUMBER
SHEET NUMBER OF SHEET WHERE
ILLUSTRATION IS REFERENCED
SHEET NUMBER OF SHEET WHERE
ILLUSTRATION IS REFERENCED
ON MULTIPLE SHEETS
DRAWING TITLES
PLANS, DIAGRAMS,
SCHEDULES,
STANDARD DETAILS,
3D REPRESENTATIONS
SECTIONS, ELEVATIONS,
ENLARGED PLANS,
SPECIFIC DETAILS
SECTIONS, ELEVATIONS,
ENLARGED PLANS,
SPECIFIC DETAILS
CROSS REFERENCING SYMBOLS
SECTION MARKER
DETAIL CALLOUT
INTERIOR
ELEVATION MARKER
EXTERIOR
ELEVATION MARKER
SECTION LETTER
SHEET NUMBER OF SHEET WHERE
SECTION IS REFERENCED
DETAIL NUMBER
INTERIOR ELEVATION LETTER
SHEET NUMBER OF SHEET WHERE
SECTION IS REFERENCED
SHEET NUMBER OF SHEET WHERE
SECTION IS REFERENCED
SHEET NUMBER OF SHEET WHERE
SECTION IS REFERENCED
ELEVATION LETTER
X-X
X-XXX
X-XXX
X
X-XXX
X
XX
X
X-XXX
X
TYPICAL
TAM DRAWING SCALES
ROOF PLANS
LIFE SAFETY FLOOR PLANS
REFLECTED CEILING PLANS
TYPICAL FLOOR PLANS
ENLARGED FLOOR PLANS
EXTERIOR ELEVATIONS
INTERIOR ELEVATIONS
BUILDING SECTIONS
WALL SECTIONS
CROSS SECTIONS
DETAILS
STAIR DETAILS
CIVIL PROFILES
HORIZONTAL
VERTICAL
1:200
20m4m 16m12m8m0m
1:100
10m2m 8m6m4m0m
1:50
5m1m 4m3m2m0m
1:100
10m2m 8m6m4m0m
1:50
5m1m 4m3m2m0m
1:100
10m2m 8m6m4m0m
1:50
5m1m 4m3m2m0m
1:10
1m0.2m 0.8m0.6m0.4m0m
1:5
0.5m0.1m 0.4m0.3m0.2m0m
1:10
1m0.2m 0.8m0.6m0.4m0m
1:20
2m0.4m 1.6m1.2m0.8m0m
1:100
10m2m 8m6m4m0m
1:50
5m1m 4m3m2m0m
A
X-XXX
X-XXX
X-XXX
X-XXX
X-XXX
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
B
C
D
2 3 4 5 1/
/2
1:
:0
P M
1/
/2
1:
:0
PM
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
Enter District
EM
S
G W
D
R O
B
ER
T L.
F O
X , P
E
-G
I0
G N
G-021
JA
R
ST
AN
D A
RD
L
EG
EN
D S
A
ND
S
YM
B O
LO
G
Y
P2 -4
U
N
SP
E C
IF
IE
D
W O
R L D
W
ID
E
G
EN
ER
A
L
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A AMPERE
A/C AIR CONDITIONING
A/E ARCHITECT/ENGINEER
AAFES ARMY & AIR FORCE EXCHANGE
SERVICE
AAV AUTOMATIC AIR VENT
ACC ACCESSIBLE
ACP ASPHALTIC CONCRETE PAVEMENT
ACV AUTOMATIC CONTROL VALVE
AD AREA DRAIN
ADDL ADDITIONAL
ADMIN ADMINISTRATION
AFF ABOVE FINISHED FLOOR
AFFF AQUEOUS FIRE FIGHTING FOAM
AFG ABOVE FINISHED GRADE
AH AMPERE HOUR
AHU AIR HANDLING UNIT
AI ANALOG INPUT
ALUM ALUMINUM
AMI ADVANCED METERING
INFRASTRUCTURE
AMP AMPERE
AO ANALOG OUTPUT
APPROX APPROXIMATE
ARCH ARCHITECTURAL
AS AIR SEPARATOR
ASC ASPHALTIC SURFACE COURSE
ASPH ASPHALT
ASSN ASSOCIATION
ASSY ASSEMBLY
AT/FP ANTI-TERRORISM FORCE
PROTECTION
AUX AUXILIARY
AVG AVERAGE
BC BACK OF CURB, BARE COPPER
BF BOTH FACES, BLIND FLANGE
BFP BACKFLOW PREVENTER
BLDG BUILDING
BM BENCHMARK
BMS BALANCE MAGNETIC SWITCH
BOL BOLLARD
BRKR BREAKER
BSP BLACK STEEL PIPE
BT BATHTUB
BTWP BALLANCE TWISTED PAIR
C CELSIUS, CHANNEL, CONDUIT,
CONDUCTOR, COMMUNICATION
CA COMPRESSED AIR
CAL CALORIE
CAO COMPRESSED AIR OUTLET
CB CATCH BASIN, CIRCUIT BREAKER
CBL CABLE
CC CENTER TO CENTER, CUBIC
CENTIMETER
CCTV CLOSED CIRCUIT TELEVISION
CD CANDELA, CEILING DIFFUSER
CE CIVIL ENGINEER(S)
CH COAT HOOK, CHANGING, CHILLER
CHH COMMUNICATIONS HAND HOLE
CHR CHILLED WATER RETURN
CHS CHILLED WATER SUPPLY
CHU CONTAINERIZED HOUSING UNIT
CI CAST IRON
CIJ CONTROL JOINT
CIP CAST-IN-PLACE, CAST IRON PIPE
CJ CONSTRUCTION JOINT, CONTROL
JOINT
CKT CIRCUIT
CL CENTER LINE
CLG CEILING
CLJ CONSTRUCTION LONGITUDINAL
JOINT
CLKG CALKING
CLR CLEAR
cm CENTIMETER cm 2 CENTIMETER SQUARED cm 3 CUBIC CENTIMETER cm/s CUBIC CENTIMETER PER SECOND
CMH COMMUNICATIONS MANHOLE
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY UNIT
CO CLEANOUT, CONDUIT ONLY
COL COLUMN
COMM COMMUNICATIONS
COMPR COMPRESSOR
CONC CONCRETE
COND CONDENSER, CONDENSATE
CONSTR CONSTRUCTION
CONT CONTINUE, CONTINUOUS
COR CONTRACTING OFFICER’S
REPRESENTATIVE, CORNER,
CHANGE ORDER REQUEST
CORR CORRIDOR
CRAC COMPUTER ROOM AIR CONDITIONING
UNIT
CS CAST STONE, CARBON STEEL
CSC CONVOY SUPPORT CENTER
CSS COMPACT SUBSTATION
CTR(S) CENTER(S)
CTRL CONTROL
CU CUBIC, COPPER
CV CONTROL VALVE
CW COLD WATER
DAS DATA ACQUISTION SYSTEM
DBL DOUBLE
DBP DISTRIBUTION PANEL
DCW DOMESTIC COLD WATER
DEG C, °C DEGREES CELSIUS
DF DRINKING FOUNTAIN
DFAC DINING FACILITY
dg DECIGRAM
DG DOOR GRILL
DH DUCT HEATER
DHW DOMESTIC HOT WATER
DI DROP INLET, DRAIN INLET,
DISCRETE INPUT
DIA DIAMETER
DIP DUCTILE IRON PIPE
dL DECILITER
DL DEAD LOAD, DIESEL
dm DECIMETER
DN DOWN
DO DISCRETE OUTPUT
DP DEW POINT, DIFFERENTIAL
PRESSURE
DR DOOR, DOUBLE RIB
DV DISTINGUISHED VISITORS
DW DOMESTIC WATER
DWG DRAWING
DXCC DIRECT EXPANSION COOLING COIL
E EAST, EASTING, EXISTING
EC EDGE OF CURB, EMPTY CONDUIT
ECV EMERGENCY CONTROL VALVE
EF EACH FACE, EXHAUST FAN
EG EXHAUST AIR GRILLE
EHC ELECTRIC HEATING COIL
EHH ELECTRIC HAND HOLE
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC(AL)
ELECT ELECTRICAL
ELR ELECTRIC REFRACTION AT RIM
ELV ELECTRIC VERTICAL ROD
RETRACTION
EMH ELECTRICAL MANHOLE
EMT ELECTRICAL METALLIC TUBING,
EMERGENCY MEDICAL TECHNICIAN
EMCS ENERGY MONITORING AND CONTROL
SYSTEM
ENT ELECTRICAL NONMETALLIC TUBING
ENTR ENTRANCE
EOL END OF LINE
EP EDGE OF PAVEMENT, ELECTRICAL
PANEL
EQ EQUAL
EQUIP EQUIPMENT
ER EXHAUST REGISTER
ES ELECTRIC STRIKE
ESS ELECTRONIC SECURITY SYSTEMS
EST ESTIMATE
ET EXPANSION TANK
ETC ET CETERA, AND SO FORTH
EW EACH WAY, EFFLUENT WATER
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION, EXPLOSION PROOF
EXST GR EXISTING GRADE
EXT EXTERIOR
F/B FROM FLOOR BELOW
FA FIRE ALARM, FRESH AIR
FACP FIRE ALARM CONTROL PANEL
FCU FAN COIL UNIT
FCV FLOW CONTROL VALVE
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FES FLARED END SECTION
FFLE FINISH FLOOR ELEVATION
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIN FINISH, FINISHED
FIN GR FINISH GRADE
FL FLOOR LINE, FLOOR,
FLASHING, FLOOD LIGHT
FLG FLANGE
FLR FLOOR
FLUOR FLUORESCENT
FLX FLEXIBLE CONDUIT
FO FIBER OPTIC
FOB FORWARD OPERATING BASE
FOC FACE OF CURB
FP FIRE PROTECTION
FS FLOOR SINK
FSS FLOW SWITCH
FSR FUEL STORAGE RECOVERY
FT FEET
FTP FUEL TRANSFER PUMP
FTR FINNED TUBE RADIATION
FUT FUTURE
FVNR FULL VOLTAGE NON-REVERSING
FXD FIXED
G GIRDER, GROUND
GA GAGE
GB GROUND BAR
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERAL, GENERATOR
G LN GAS LINE
GL GLASS
GLZD GLAZED
GM GAS METER
GND GROUND
GR GROSS, GRADE
GRL GRILLE
GRTG GRATING
GTV GATE VALVE
GW GUY WIRE
GYP BD GYPSUM WALL BOARD
ha HECTARE
HB HOSE BIBB
HC HEATING COIL
HCD HOLLOW CORE DOOR
HCP HANDICAP PUSHBUTTON
HD HEAD
HDB HEATING DISTRIBUTION BOX
HDPE HIGH DENSITY POLYETHELENE
HDW HARDWARE
HDWL HEADWALL
HGR HANGER
HT HEIGHT
hL HECTOLITER hm HECTOMETER
HM HOLLOW METAL
HMA HOT MIX ASPHALT
HNDRL HANDRAIL
HORIZ HORIZONTAL
HP HIGH PRESSURE, HEAT PUMP
HPT HIGH POINT
HQ HEADQUARTERS
HR HOUR
HRCP HEAT RECOVERY COIL PUMP
HRR HEAT RECOVERY RETURN
HRS HEAT RECOVERY SUPPLY
HV HIGH VOLTAGE
HW HOT WATER
HWC HOT WATER CIRCULATION
HWCP HOT WATER CIRCULATION PUMP
HWP HOT WATER PUMP
HWR HEATING WATER RETURN
HWS HEATING WATER SUPPLY
HEX HEAT EXCHANGER
Hz HERTZ
ID INSIDE DIAMETER
IE INVERT ELEVATION
IF INSULATING FLANGE
INSUL INSULATION
INSTR INSTRUMENT
INT INTERIOR
INV INVERT
ITN INFORMATION TECHNICAL NODE
JCT JUNCTION
JOH JAMB OPENING HEIGHT
JOW JAMB OPENING WIDTH
JR JOINT REINFORCING
JT JOINT
k KILO
K KELVIN
kCAL KILOCALORIE
KCMIL THOUSAND CIRCULAR MILLS
kg KILOGRAM kHz KILOHERTZ kL KILOLITER km KILOMETER km 2 SQUARE KILOMETER
KM/H KILOMETER PER HOUR
KM/S KILOMETER PER SECOND
KPA KILOPASCAL
KS KITCHEN SINK
KV KILOVOLT
KVA KILOVOLT AMPERE
KVAH KILOVOLT AMPERE PER HOUR
L LITER
L/S LITER PER SECOND
LAB LABORATORY
LAV LAVATORY
LCM LOOSE CUBIC METER
LG LONG, LENGTH
LLA LOW LEVEL ALARM
LM LUMEN
LINTL LINTEL
LP LIGHT POLE
LPT LOW POINT
LPW LUMENS PER WATT
LRA LOCKED ROTOR AMPS
LSA LIFE SUPPORT AREA
LT LEFT
LTG LIGHTING
LV LOW VOLTAGE
LVR LOUVER
M METER
M2 SQUARE METER
M3 CUBIC METER
M3/S CUBIC METER PER SECOND
M/S METER PER SECOND
M MEN
MM MILLIMETERS
MA MILLIAMPERE
MA MEDICAL AIR
MACH MACHINE
MAINT MAINTENANCE
MAU MAKEUP AIR UNIT
MAV MANUAL AIR VENT
MAX MAXIMUM
MCA MINIMUM CIRCUIT AMPS
MCC MOTOR CONTROL CENTER
MCD METAL COVERED DOOR
MECH MECHANICAL
MFG MANUFACTURING
MH MANHOLE
MHO MAGNETIC HOLD OPEN
MHz MEGAHERTZ
MIN MINIMUM, MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
MJ MECHANICAL JOINT
mm MILLIMETER mm 2 SQUARE MILLIMETER mm 3 CUBIC MILLIMETER
MO MASONARY OPENING
MON MONITOR, MONUMENT
ms MILLISECOND
MS MOP SINK
MTG MOUNTING
MTL METAL
MTS MANUAL TRANSFER SWITCH
mV MILLIVOLT
MVA MEGAVOLT-AMPERE
mW MILLIWATT
MW MONITORING WELL, MEGAWATT
MWh MEGAWATT HOUR
MWR MORALE, WELFARE &
RECREATION
N NORTH, NORTHING, NEWTON
NA NOT APPLICABLE
NC NORMALLY CLOSED
NO NORMALLY OPEN, NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OA OUTDOOR AIR
OC ON CENTER
OD OUTSIDE DIAMETER
OFF OFFICE
OGL OBSCURE GLASS
OPNG OPENING
OSP OUTSIDE PLANT
P PUMP, POLE
P/V PRESSURE VACUUM
PA PASCAL
PA PUBLIC ADDRESS
PASS PASSAGE, PASSENGER
PC POINT OF CURVATURE, DESKTOP
COMPUTER
PCC PORTLAND CEMENT CONCRETE
PCS PERMANENT CHANGE OF STATION
PDM POSITIVE DISPLACEMENT METER
PDS PROTECTIVE DISTRIBUTION SYSTEM
PE PLAIN END, POLYETHYLENE
PED PEDESTAL
PERF PERFORATED, PERFORM
PET PROTECTED ENTRANCE TERMINAL
PH PHASE, PENTHOUSE
PI POINT OF INTERSECTION
PIV POST INDICATOR VALVE, PIVOTED
PL PROPERTY LINE, PLATE
PLAS PLASTER
PLG PILING
PNL PANEL
POC POINT ON CURVE
POT POINT OF TANGENCY
PP POWER POLE, POWER PANEL,
POLYPROPYLENE
PR PAIR, PIPE RAIL
PRCST PRECAST
PRV PRESSURE REGULATING VALVE
PS CONC PRESTRESSED CONCRETE
PS PRESSURE SENSOR, PULL STATION,
POLYSTYRENE
PSF POUNDS PER SQUARE FOOT
PSIG POUNDS PER SQUARE INCH GAGE
PT POINT
PTZ PAN//TILT/ZOOM
PVC POLYVINYL CHLORIDE
PVMT PAVEMENT
QA/QC QUALITY ASSURANCE/QUALITY
CONTROL
QD QUICK DISCONNECT
QTY QUANTITY
R RADIUS, RISER, RANGE
R/U REFRIGERATION UNIT
RAD RADIAN, RADIATOR, RETURN AIR
DUCT
RAH RETURN AIR HUMIDITY
RAT RETURN AIR TEMPERATURE
RC REINFORCED CONCRETE
RCB REINFORCED CONCRETE BOX
RCP REINFORCED CONCRETE PIPE
RD ROAD, RETURN DIFFUSER, ROOF
DRAIN
REC RECESSED, RECREATIONAL
REC C RECESSED CONVECTOR
RECT RECTANGULAR
REG REGISTER
REINF REINFORCED
REQD REQUIRED
RET RETURN
REV REVISION, REVISED, REVOLUTIONS
REX REQUEST TO EXIT
RF REPLACEMENT FACILITY, RADIO
FREQUENCY
RG RETURN AIR GRILLE
RGH ROUGH
RGS RIGID GALVANIZED STEEL
RHC REHEAT COIL
RKVA REACTIVE KILOVOLT AMPERES
RL REFRIGERANT LIQUID
RLG RAILING
RM ROOM
ROW RIGHT OF WAY
RPM REVOLUTIONS PER MINUTE
RR RETURN REGISTER, ROOF ROLLING,
RAILROAD
RS REFRIGERANT SUCTION
RT RIGHT
RTU ROOF TOP UNIT
RW RAW WATER, ROADWAY
S SOUTH
SV STACK VENT
SA SUPPLY AIR
SAN SANITARY SEWER
SB SOIL BORING, SPLASH BLOCK
SC SOLID CORE
SCHED SCHEDULE
SCP SCUPPER
SD STORM DRAIN
SECT SECTION
SFM SANITARY FORCE MAIN
SG SUPPLY AIR GRILLE
SH SHOWER
SHT SHEET, SHAFT
SIG SIGNAL
SIM SIMILAR
SK SINK, SKETCH
SLDG SLIDING
SP STATIC PRESSURE, SUMP
SPA SPACE
SPEC SPECIFICATIONS
SPCL SPECIAL
SPO DUCTLESS SPLIT UNIT OUTSIDE
SQ SQUARE
SS SANITARY SEWER
SSD SUBSURFACE DRAIN
SST STAINLESS STEEL
ST STORM WATER
STA STATION
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
T TOP, TREAD, THERMOSTAT
T&B TOP AND BOTTOM
TB TILE BASE, THROUGH BOLT
TD TRENCH DRAIN
TDH TOTAL DYNAMIC HEAD
TEJ THICKENED EXPANSION JOINT
TEL TELEPHONE
TG TRANSFER GRILLE
TGP TEMPORARY GENERATOR PAD
TFA TO FLOOR ABOVE
TFB TO FLOOR BELOW
TGP TEMPORARY GENERATOR PAD
THK THICKNESS
THRES THRESHOLD
TMGB TELECOMMUNICATIONS MAIN
TMV TEMPERATURE MIXING VALVE
TOB TOP OF BANK, TOP OF BEAM
TOC TOP OF CONCRETE, TOP OF CURB
TOE TOE OF SLOPE
TOG TOP OF GRATING
TOS TOP OF STEEL, TOP OF SLOPE
TOW TOP OF WALL
TS TEMPERATURE SWITCH
TR TELECOMMUNICATION ROOM
TRANS TRANSOM, TRANSPARENT
TS & V TAPPING SLEEVE AND VALVE
TV TELEVISON
TW TREATED WATER
TYP TYPICAL
UGND UNDERGROUND
UH UNIT HEATER
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
UOP UNLESS OTHERWISE NOTED
UP UTILITY POLE
UPS UNINTERRUPTIBLE POWER SUPPLY
UPVC UNPLASTICIZED POLYVINYL
UR URINAL
UTIL UTILITY
V VOLT, VENT
VA VOLT AMPERE
VAC VACUUM
VAM VOLT-AMMETER
VAO VACUUM OUTLET
VAP VACUUM PUMP
VB VALVE BOX, VACUUM BREAKER
VC VERTICAL CURVE
VCT VINYL COMPOSITION TILE
VEL VELOCITY
VFD VARIABLE FREQUENCY DRIVE
VOLT VOLTAGE
VRLY VOLTAGE RELAY
VPC VERTICAL POINT OF CURVE
VPI VERTICAL POINT OF INTERSECTION
VPT VERTICAL POINT OF TANGENCY
VS VENT STACK, VOLTMETER SWITCH
VSA VEHICLE SECURITY AREA
VTR VENT THRU ROOF
W/ WITH
W/O WITHOUT
WB WET BULB, WOOD BASE
WC WATER CLOSET, WALL COVERING
WCC WATER COOLING COIL
WCO WALL CLEANOUT
WFLX WEATHERPROOF FLEXIBLE CONDUIT
WHM WATT HOUR METER
WDB WATER DISTRIBUTION BOX
WG WATER GAUGE
WGL WIRED GLASS
WH WALL HYDRANT
WHS WAREHOUSE
WL WATER LINE, WIND LOAD
WM WATER METER
WS WATER SOFTENER
WSEL WATER SURFACE ELEVATION
WST WATER STORAGE TANK
WTS WATERSTOP
WV WATER VALVE
XFMR TRANSFORMER
YCO YARD CLEANOUT
YH YARD HYDRANT
YR YEAR
NOTES:
1. THE LIST OF ABBREVIATIONS IS SHOWN AS A GUIDE ONLY
AND DOES NOT NECESSARILY INCLUDE ALL ABBREVIATIONS
USED. SOME ABBREVIATIONS LISTED MAY NOT HAVE BEEN
USED. CONSULT AEC/NCS FOR FULL LIST OF ABBREVIATIONS.
2. SOME ABBREVIATION REPRESENT SYMBOLS FOR UNITS OF
MEASURE, AND INTENTIONALLY INCLUDE LOWERCASE LETTERS OR
SUPERSCRIPTS.
3. REFER TO THE GENERAL LEGEND ON SHEET G-021
STANDARD ABBREVIATION LIST
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
B
C
D
2 3 4 5 1/
/2
1:
:1
P M
1/
/2
1:
:1
PM
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
Enter District
EM
S
G W
D
R O
B
ER
T L.
F O
X , P
E
-G
I0
G N
G-031
JA
R
ST
AN
D
AR
D A
B
BR
EV
IA
TI
O
N S
P2 -4
U
N
SP
E C
IF
IE
D
W O
R L D
W
ID
E
G
EN
ER
A
L
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
SYMBOL DESCRIPTION
STRUCTURAL LEGEND
CONCRETE
EARTH FILL
GROUT
CONCRETE MASONRY
UNIT (CMU)
GRAVEL FILL
SLOPE DIRECTION
SLAB PRIMARY
REINFORCING DIRECTION
[±XXXX]
INDICATES ELEVATION
REFERENCED TO FINISHED
FIRST FLOOR
1 KEYED CONSTRUCTION
NOTE
[±XXXX]
SPOT ELEVATION
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
B
C
D
2 3 4 5 1/
/2
1:
:0
P M
1/
/2
1:
:0
PM
A
IR
D
EF
E N
SE
IM
PO
RO
V E
M
EN
TS
-0 7-
MIDDLE EAST DISTRICT
JM
G
JM
G
JE
FF
ER
Y
P . R
AN
EY
, C H
EI
F
A C
H
IT
EC
TU
R
AL
B R
AN
C
H
S S0
G
N
SS-001
W
IN
C H
E
ST
E R
, V A
R
LT
G
EN
ER
A
L
NO
TE
S
P2 -4
U
N
SP
EC
IF
IE
D
L O
C A T
IO
N
ST
AN
D
AR
DS
GENERAL NOTES
19. SLAB OPENINGS/PENETRATIONS SIZES SHOWN ON THE FACILITY DRAWINGS ARE
APPROXIMATE. COORDINATE FINAL SIZES WITH THE EQUIPMENT PROVIDED.
20. THE UNIT OF MEASURE ASSOCIATED WITH DIMENSIONS AND ELEVATIONS IS
MILLIMETERS (mm) UNLESS OTHERWISE NOTED.
21. SEE INDIVIDUAL FACILITIES FOR DESIGN LOADS
ALL LOADS ARE IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE, 2012
UNO.
22. FOUNDATIONS HAVE BEEN DESIGNED FOR AN ASSUMED ALLOWABLE BEARING
CAPACITY OF 95.7 KPa (2,000 PSF) AND SUBGRADE MODULUS OF 27.15 kPa/mm (100
LBS/SQ. IN/IN). Ka AND Kp ARE ASSUMED TO BE 0.33 AND 3.0 RESPECTIVELY.
CONTRACTOR TO PERFORM A GEOTECHNICAL INVESTIGATION FOR EACH SITE TO
VERIFY ACTUAL SOIL PROPERTIES MEETS THE MINIMUM REQUIREMENTS OF
THESE ASSUMED VALUES.
23. SHOULD THIS DESIGN BE USED IN AREAS WHERE THE DESIGN CRITERIA (SEISMIC,
WIND, AND GEOTECHNICAL) DOES NOT MEET THE MINIMUM REQUIREMENTS OR IS
MORE STRINGENT THAN THE INFORMATION LISTED ABOVE, THIS DESIGN WILL BE
VOIDED AND MUST BE REDESIGNED USING THE SEISMIC, WIND, AND
GEOTECHNICAL DATA FOR THAT SPECIFIC LOCATION.
24. METAL BUILDING SYSTEMS SHALL BE AS REQUIRED IN THE SPECIFICATIONS AND
AS NOTED ON THE DRAWINGS.
25. FOOTING ELEVATIONS GIVEN ARE TO TOP OF FOOTING UNO.
GENERAL NOTES
1. STRUCTURAL DESIGN IS IN ACCORDANCE WITH THE FOLLOWING CODES AND
SPECIFICATIONS
A. 2012 INTERNATIONAL BUILDING CODE (IBC)
B. ASCE 7-10, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER
STRUCTURES
C. ACI 318-11, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE.
D. ACI 530-11, BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES
E. UFC 4-010-01 DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS
DATED 9 FEBRUARY 2012 WITH CHANGE 1 DATED 1 OCTOBER 2013
F. UFC 3-301-01, STRUCTURAL ENGINEERING, DATED 1 JUNE 2013 WITH CHANGE
1 DATED 15 MAY 2014
G. UFC 3-310-04 SEISMIC DESIGN FOR BUILDINGS, DATED 1 JUNE 2013
2. USE STRUCTURAL DRAWINGS IN CONJUNCTION WITH ALL OTHER DRAWINGS. FOR
LOCATION AND DIMENSIONS OF ITEMS INCLUDING, BUT NOT LIMITED TO,
PARTITIONS, DEPRESSIONS, GROOVES, SLEEVES, CURBS, OPENINGS, EMBEDDED,
OR ATTACHED ITEMS, REFER TO ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND
PLUMBING DRAWINGS.
3. ALL BUILDING ELEVATIONS ARE GIVEN AS REFERENCE ELEVATIONS TO THE
FINISHED GROUND FLOOR ELEVATION. A REFERENCE FLOOR ELEVATION OF 0.00
mm IS USED FOR THE TOP OF SLAB ON GRADE.
4. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AFFECTING THE
WORK AT THE JOB SITE.
5. REPORT DISCREPANCIES IN DIMENSIONS BETWEEN DIFFERENT DRAWINGS TO
THE CONTRACTING OFFICER PRIOR TO BEGINNING WORK IN AREAS THAT WILL BE
AFFECTED.
6. ALL STRUCTURAL WORK AND MATERIALS SHALL CONFORM TO THE
REQUIREMENTS OF THE PROJECT SPECIFICATIONS.
7. DO NOT SCALE DRAWINGS.
8. FOR ADDITIONAL INFORMATION REFER TO INDIVIDUAL SHEETS FOR EACH
STRUCTURE OR FACILITY.
9. ALL STRUCTURES SHALL BE FOUNDED ENTIRELY ON NATURAL MATERIAL OR
ENTIRELY ON COMPACTED STRUCTURAL FILL. FOR STRUCTURES FOUNDED ON
BED ROCK, PROVIDE A MEDIUM OF LEAN CONCRETE HAVING A MINIMUM 28-DAY
COMPRESSIVE STRENGTH OF 14 MPa (2000 PSI) BETWEEN FOOTING BASES AND
BED ROCK LAYER, AS REQUIRED.
10. ALL FOOTING EXCAVATIONS SHALL BE INSPECTED AND APPROVED BY
CONTRACTING OFFICER OR HIS APPROVED AGENT PRIOR TO PLACING CONCRETE.
11. WHERE CERTAIN FEATURES ARE NOT FULLY SHOWN OR DETAILED ON THE
CONTRACT DOCUMENTS, THEIR CONSTRUCTION SHALL BE OF THE SAME
CHARACTER AS FOR SIMILAR CONDITIONS THAT ARE FULLY SHOWN OR DETAILED.
12. DETAILS ENTITLED OR NOTED AS "TYPICAL" APPLY NOT ONLY WHERE
SPECIFICALLY INDICATED OR REFERENCED, BUT ALSO IN ALL OTHER CASES
WHERE THE NATURE OF THE CONSTRUCTION REQUIRES THEIR USE. DETERMINE
APPLICABILITY OF TYPICAL DETAILS FROM THE SIMILARITY OF A CONSTRUCTION
CONDITION TO ANOTHER CONDITION WHERE DETAIL IS SPECIFICALLY INDICATED
OR REFERENCED.
13. THE STRUCTURAL DRAWINGS CONTAINED HEREIN REPRESENT THE FINISHED
STRUCTURE. PROVIDE ALL TEMPORARY GUYING AND BRACING REQUIRED TO
ERECT AND HOLD THE STRUCTURE IN PROPER ALIGNMENT UNTIL ALL
STRUCTURAL WORK, INCLUDING CONNECTIONS, IS COMPLETE. THE ANALYSIS,
DESIGN, SAFETY, ADEQUACY, AND INSPECTION OF ERECTION BRACING, SHORING
FORMWORK, AND OTHER TEMPORARY SUPPORTS ARE THE SOLE RESPONSIBILITY
OF THE CONTRACTOR.
14. CONSTRUCTION MEANS, METHODS, TECHNIQUE, SEQUENCES, AND SUPERVISION
OF THE WORK ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
15. REPRODUCTION OF CONTRACT DRAWINGS SHALL NOT BE USED AS SHOP
DRAWINGS UNDER ANY CIRCUMSTANCE.
16. ALL DIMENSIONS ARE OUT TO OUT OF STRUCTURAL ELEMENTS AND DO NOT
INCLUDE ARCHITECTURAL TREATMENTS SUCH AS PLASTER FINISH. CONCRETE
AND MASONRY OPENINGS THAT ARE INDICATED ON THE FACILITY DRAWINGS MAY
VARY WITH THE EQUIPMENT PROVIDED. THE CONTRACTOR SHALL COORDINATE
OPENING REQUIREMENTS WITH ALL TRADES.
17. ALL FOOTINGS SHALL BE CENTERED ON COLUMN LINES UNLESS INDICATED
OTHERWISE.
18. MANUFACTURERS AND MODEL NUMBERS ARE LISTED TO ESTABLISH REQUIRED
QUALITY CHARACTERISTICS AND MATERIALS OR ITEMS TO BE PROVIDED. THEY
ARE NOT INTENDED TO LIMIT COMPETITION. AN APPROVED EQUAL PRODUCT MAY
BE CONSIDERED AS ACCEPTABLE.
STRUCTURAL ABBREVIATIONS
SYMBOL DESCRIPTION
AHR ANCHOR
BD BAR DIAMETER
BOC BOTTOM OF CONCRETE
BOM BOTTOM OF MASONRY
BOT BOTTOM
BRG BEARING
CLR CLEAR
CONN CONNECTION
EA EACH
ELEV ELEVATION
EOS EDGE OF SLAB
EQ EQUAL
FD FLOOR DRAIN
FFE FINISHED FLOOR ELEVATION
FTG FOOTING
MBS METAL BUILDING SYSTEM
NA NOT APPLICABLE
NTS NOT TO SCALE
OPP OPPOSITE
PJF PREMOLDED JOINT FILLER
REINF REINFORCING
SCH SCHEDULE
SF STEPPED FOOTING
SJ SLAB SAWED (CONTRACTION) JOINT
SL SLOPED
SOG SLAB ON GRADE
SW SHEAR WALL
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TS THICKENED SLAB
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
V SHEAR
VERT VERTICAL
WP WORKING POINT
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
1. THIS TABLE CONFORMS TO ACI 318 CLASS
B TENSION LAP SPLICES FOR NORMAL
WEIGHT CONCRETE AND 420 kN/cm2
UNCOATED REINFORCEMENT WITH CLEAR
SPACING BETWEEN BARS GREATER THAN
50 mm AND CLEAR COVER GREATER THAN 25 mm. ADJUSTMENTS SHALL BE MADE
FOR OTHER MORE CRITICAL CONDITIONS.
2. PROVIDE SPLICES AS SHOWN UNLESS
OTHERWISE NOTED ON THE DRAWINGS,
SUBSTITUTION OF SPLICE LENGTHS
SHORTER THAN THOSE GIVEN SHALL BE
IN ACCORDANCE WITH ALL PROVISIONS OF
ACI 318 WITH WRITTEN APPROVAL OF THE
CONTRACTING OFFICER.
3. TOP BARS ARE ANY HORIZONTAL
REINFORCEMENT PLACED SUCH THAT
MORE THAN 300 mm OF CONCRETE IS
BELOW THE REINFORCEMENT.
4. EMBEDMENT FOR STANDARD HOOK (Ldh) IS
THE MINIMUM STRAIGHT LINE DISTANCE
FROM THE CRITICAL SECTION IN THE BAR
(AT A JOINT) TO THE FARTHEST EDGE OF
THE HOOK, SEE STANDARD HOOK DETAILS.
TABLE NOTES
28 MPa (4000 PSI) CONCRETE
BAR
SIZE
(mm)
MIN DEVELOPMENT AND LAP SPLICE LENGTHS (mm)
TYPICAL BARS TOP BARS
DEVELOPMENT
LENGTH (Ld)
D10
D12
D16
D19
D22
D25
D29
D32
HOOK
DEVELOPMENT
(Ldh)
TYPICAL BARS TOP BARS
CLASS 'B' LAP SPLICE
LENGTH (1.3*Ld)
D36 1685 2190 69028452190
90° HOOK 180° HOOK
CRITICAL SECTION CRITICAL SECTION
Ldh d
A O
R G dD
Ldh
A OR G
HOOK
D29 THRU D36 = 5d
D10 THRU D25 = 4d, BUT 64 MIN
J d
D
STANDARD HOOKS
D
ET
AI
LI
N G
D
IM
E N
SI
O
N
A OR G
d
D19 THRU D36 - 12d D10 THRU D16 =6d, BUT 64 MIN
D E
TA
IL
LI
N
G D
IM
EN
S
IO
N d
D
D
A O
R G
H O
O K
D
D =8d FOR D29 THRU D36
D =4d FOR D10 THRU D16 D =6d FOR D19 THRU D25
6d - 75 MIN
H
135° HOOK90° HOOK
STIRRUP - TIE HOOKS
STANDARD REINFORCEMENT BAR NOMENCLATURE
ASTM A615
BAR SIZES
ALT METRIC
BAR SIZES
D10
D12
D16
D19
D22
D25
D29
D32
10 mm
14 mm
16 mm
20 mm
22 mm
26 mm
30 mm
32 mm
STANDARD HOOK
INSIDE DIA
BAR BEND
180° HOOK 90° HOOK
A OR G J A OR G
60 125 80 155
80 155 105 200
95 180 130 250
115 205 155 300
135 250 175 375
155 275 205 425
240 375 300 475
275 425 335 550
STIRRUP AND TIE HOOKS
135° HOOK 90° HOOK
A OR G H A OR G
105 65 105
115 80 115
140 155
DO NOT USE
DO NOT USE
DO NOT USE
DO NOT USE
DO NOT USE
INSIDE DIA
BAR BEND
D36 36 mm 305 475 375 600 DO NOT USE
EQUIVALENT STEEL WELDED
WIRE FABRIC SIZES
WIRE REINFORCING
INSTITUTE DESIGNATION
METRIC SIZES (mm)
WIRE SPACING WIRE DIAMETER
6 x 6 - W1.4 x W1.4 6 x 6 - W2.1 x W2.1 6 x 6 - W2.9 x W2.9 6 x 6 - W4.0 x W4.0
150 x 150 3.0 x 3.0 150 x 150 4.0 x 4.0 150 x 150 5.0 x 5.0 150 x 150 6.0 x 6.0
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
B
C
D
2 3 4 5 1/
/2
1:
:1
P M
1/
/2
1:
:1
PM
A
IR
D
EF
E N
SE
IM
PO
RO
V E
M
EN
TS
-0 7-
MIDDLE EAST DISTRICT
JM
G
JM
G
JE
FF
ER
Y
P . R
AN
EY
, C H
EI
F
A C
H
IT
EC
TU
R
AL
B R
AN
C
H
S S0
G
N
SS-002
W
IN
C H
E
ST
E R
, V A
R
LT
C O
N C
RE
TE
N O
T E S
P2 -4
U
N
SP
EC
IF
IE
D
L O
C A T
IO
N
ST
AN
D
AR
DS
CONCRETE NOTES
1. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE PROVISIONS
OF THE AMERICAN CONCRETE INSTITUTE (ACI) "SPECIFICATIONS FOR STRUCTURAL
CONCRETE" (ACI 301-10)
2. CAST-IN-PLACE CONCRETE SHALL ATTAIN THE FOLLOWING MINIMUM 28-day COMPRESSIVE STRENGTH (f'c):
ALL CONCRETE 28.0 MPa (4000 PSI)
3. CONCRETE DENSITY SHALL BE NORMAL WEIGHT UNLESS SPECIFICALLY OTHERWISE
NOTED.
4. CONCRETE REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM
A615/A615M, GRADE 420 UNO.
5. CONCRETE REINFORCING STEEL SHALL BE CONTINUOUS UNLESS OTHERWISE
INDICATED. CONTINUOUS REINFORCING STEEL SHALL BE LAPPED IN ACCORDANCE
WITH THE REQUIREMENTS OF ACI 318.
6. MINIMUM CONCRETE COVER (mm) FOR REINFORCING STEEL SHALL BE AS INDICATED.
IN NO CASE SHALL REINFORCEMENT COVER BE LESS THAN THE REQUIREMENTS OF
ACI 301.
A. CONCRETE DEPOSITED AGAINST THE GROUND 75
B. CONCRETE EXPOSED TO EARTH OR WEATHER 50
C. CONCRETE NOT EXPOSED TO EARTH OR WEATHER:
BEAMS AND COLUMNS 40
SLABS AND WALLS 20
SLAB-ON-GRADE 60
7. CONCRETE REINFORCING STEEL MARKED STANDARD HOOK SHALL HAVE A
90-DEGREE HOOK UNLESS OTHERWISE NOTED. STIRRUP, TIES AND 180-DEGREE
HOOKS AND 90-DEGREE HOOKS SHALL CONFORM TO THE REQUIREMENTS OF ACI
318.
8. PROVIDE 13 mm THICK JOINT FILLER MATERIAL WHERE SLABS ON GRADE ABUT
VERTICAL SURFACES.
9. ALL EMBEDDED ITEMS SHALL BE PROPERLY PLACED, ACCURATELY POSITIONED, AND
MAINTAINED SECURELY IN PLACE PRIOR TO AND DURING CONCRETE PLACEMENT.
10. REINFORCING STEEL SHALL BE SPREAD AT SLEEVES, TIEBACKS RECESSES AND
OTHER EMBEDDED ITEMS UNLESS OTHERWISE INDICATED. REINFORCEMENT SHALL
NOT BE CUT TO FACILITATE PLACEMENT OF EMBEDDED ITEMS.
11. NO CONCRETE SHALL BE PLACED UNTIL THE CONTRACTING OFFICER OR THE
CONTRACTING OFFICER'S DESIGNATED REPRESENTATIVE HAS INSPECTED ALL
EMBEDDED WORK, INCLUDING REINFORCEMENT.
12. ALL EXPOSED CONCRETE EDGES SHALL BE CHAMFERED 20 mm OR AS INDICATED.
13. ALUMINUM SHALL NOT BE PLACED IN DIRECT CONTACT WITH CONCRETE UNLESS
EFFECTIVELY COATED OR COVERED TO PREVENT ALUMINUM-CONCRETE REACTION
AND ELECTROLYTIC ACTION BETWEEN ALUMINUM AND STEEL.
14. WHEN A SPECIFIED REINFORCING BAR IS NOT AVAILABLE, THE NEXT LARGER
(DIAMETER) SIZE BAR MAY BE SUBSTITUTED.
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
B
C
D
2 3 4 5 1/
/2
1:
:1
P M
1/
/2
1:
:1
PM
A
IR
D
EF
E N
SE
IM
PO
RO
V E
M
EN
TS
-0 7-
MIDDLE EAST DISTRICT
JM
G
JM
G
JE
FF
ER
Y
P . R
AN
EY
, C H
EI
F
A C
H
IT
EC
TU
R
AL
B R
AN
C
H
S S0
G
N
SS-003
W
IN
C H
E
ST
E R
, V A
R
LT
M A
SO
N
R Y
N O
TE
S
P2 -4
U
N
SP
EC
IF
IE
D
L O
C A T
IO
N
ST
AN
D
AR
DS
CONCRETE MASONRY UNIT (CMU) NOTES
4. CRACK CONTROL JOINT
A. USE PREMOLDED CONTROL JOINT KEY INSERTS WITH SASH BLOCK: USE CORRUGATED
METAL SEPARATOR AT BOND BEAM LOCATIONS
B. LOCATE CONTROL JOINT WHERE INDICATED ON THE ARCHITECTURAL FLOOR PLANS,
OR WHERE NOT INDICATED AS LISTED BELOW.
i. LOCATE APPROXIMATELY 1/2 THE WALL HEIGHT FROM WALL INTERSECTIONS.
ii. LOCATE AT SPACING NOT GREATER THAN 7300 mm IN INTERIOR WALLS; 4400 mm IN
EXTERIOR WALLS.
iii. AVOID CREATING SLIP PLANES AT DOOR OR WINDOW LOCATIONS.
iv. LOCATE ABOVE EXPANSION JOINTS IN SUPPORTING CONCRETE FLOOR, BEAMS, OR
WALLS.
v. DO NOT PROVIDE INTERMEDIATE CONTROL JOINTS IN PARAPET WALL UNLESS SO
INDICATED ON THE ARCHITECTURAL FACILITY DRAWINGS.
5. EXPANSION/CONTRACTION JOINTS
A. PROVIDE A MINIMUM 20 mm GAP BETWEEN THE TOP OF THE CMU WALL AND THE
BOTTOM OF THE CONCRETE STRUCTURE.
B. PROVIDE A MINIMUM 20 mm GAP BETWEEN THE END OF AN INTERIOR CMU WALL AND
THE SIDE OF A CONCRETE BEAM.
C. PROVIDE CONTINUOUS COMPRESSIBLE FILLER OR FIRE SAFING INSULATION AS
REQUIRED (FULL WIDTH AND FULL LENGTH) OF THE SAME THICKNESS AS THE JOINT.
6. TOP OF WALL SUPPORT ANCHORS
A. PROVIDE SUPPORTS ANCHORS AS INDICATED IN DETAILS FOR EXTERIOR WALLS AND
INTERIOR PARTITIONS AND AS LISTED BELOW.
B. LOCATED AT DISCONTINUOUS ENDS OF WALLS, AT EACH SIDE OF INTERMEDIATE
CONTROL JOINTS, AND AT EACH SIDE ABOVE OPENINGS WIDER THAN 2000 mm.
C. TWO CELLS UNDER EACH TOP ANCHOR SHALL BE FULLY GROUTED. SOLID MASONRY
UNITS MAY BE PROVIDED.
7. LINTELS:
A. PROVIDE MASONRY LINTELS ABOVE OPENINGS IN MASONRY WALLS AS REQUIRED. SEE
DRAWING SS-510
CONCRETE MASONRY UNIT (CMU) NOTES
1. GENERAL
A. ENGINEERED MASONRY IS DESIGNED IN ACCORDANCE WITH "BUILDING CODE
REQUIREMENTS FOR MASONRY STRUCTURES" (ACI 530-11).
B. UNITS: ASTM C90, MINIMUM COMPRESSIVE STRENGTH = 14.0 MPa (2000 PSI) MORTAR: ASTM C270 TYPE S = 14.0 MPa (2000 PSI) ASSEMBLY/PRISM MINIMUM COMPRESSIVE STRENGTH, f'm = 17.3 MPa (2500 PSI) GROUT: ASTM C476, MINIMUM COMPRESSIVE = 17.3 MPa (2500 PSI) REINFORCING STEEL BARS: Fy = 420 MPa (60,000 PSI)
C. FULLY GROUT ALL CELLS OF EXTERIOR WALLS AND ALL CELLS CONTAINING
REINFORCING STEEL OR ANCHORS
D. CONSOLIDATE AND RECONSOLIDATE GROUT IN ASSEMBLED WALLS.
E. USE FULL CONTACT LAP SPLICES FOR REINFORCING STEEL IN CMU WALLS AS
FOLLOWS:
D12 BARS: MINIMUM 600 mm D16 BARS: MINIMUM 750 mm D19 BARS: MINIMUM 900 mm
F. WHERE STRUCTURAL STEEL MEMBERS PENETRATE CMU WALLS, PROVIDE FIRE
RESISTIVE CLOSURE AS REQUIRED ALLOWING FOR 25 mm CLEARANCE AROUND STEEL.
PACK WITH FIRE SAFING INSULATION AND INSTALL A 22 GAGE (0.85mm) GALVANIZED
SHEET METAL ENCLOSURE SECURED TO WALL. SEAL ALL AROUND WITH FIRE-RESISTIVE
SEALANT.
G. USE RUNNING BOND PATTERN, UNLESS INDICATED OTHERWISE.
H. PROVIDE SUPPORT AT THE TOP OF WALLS, UNLESS INDICATED OTHERWISE. SEE
NOTE 6.
2. VERTICAL REINFORCEMENT
A. UNLESS OTHERWISE INDICATED, PROVIDE 1 - D16 VERTICAL CENTERED IN THE WALL
AT THE FOLLOWING SPACING:
WALL* MAX HEIGHT (mm) MAX SPACING (mm)
INTERIOR* 4500 1200
EXTERIOR* 3600 1200
EXTERIOR* 4500 800
EXTERIOR* 6000 400
CANTILEVER PARAPET 1200 1200
*WALLS ARE SUPPORTED AT TOP AND BOTTOM
B. PROVIDE ONE ADDITIONAL VERTICAL REINFORCEMENT AT EACH SIDE OF CONTROL
JOINTS, AT INTERSECTION OF EXTERIOR WALLS, AND AT EACH SIDE OF ALL MASONRY
OPENINGS GREATER THAN 400 mm IN WIDTH. IN OPENINGS WIDER THAN 1200 mm
PROVIDE ADDITIONAL VERTICAL REINFORCEMENT IN TWO ADJACENT CELLS ON EACH
SIDE OF THE OPENING. ADDED VERTICAL REINFORCEMENT SHALL BE CONTINUOUS FOR
THE FULL HEIGHT OF WALL UNO. SEE ADD BAR DETAIL 2/SS-506
C. PROVIDE FOUNDATION DOWELS SAME SIZE AND SPACING AS VERTICAL
REINFORCEMENT IN THE WALL ABOVE. FOUNDATION DOWELS SHALL EXTEND A MINIMUM
OF 350 mm INTO THE CONCRETE FOUNDATION SLAB OR BEAM. AT THICKENED SLABS, EXTEND DOWELS TO WITHIN 50 mm OF THE BOTTOM OF THE SLAB AND PROVIDE A
STANDARD 90° HOOK.
D. EXTEND ALL VERTICAL BARS FROM THE BOTTOM COURSE THROUGH THE TOP MOST
BOND BEAM.
3. HORIZONTAL REINFORCEMENT
A. PROVIDE HORIZONTAL JOINT REINFORCEMENT OR REINFORCED BOND BEAMS AS
PRESCRIBED BELOW.
B. PROVIDE STANDARD 4 LADDER TYPE JOINT REINFORCEMENT AT 400 mm MAX VERTICAL SPACING OR AS INDICATED. LAP ENDS 150 mm MINIMUM. USE PREFORMED L
AND T SECTIONS AT CORNERS AND INTERSECTIONS OF WALLS AS REQUIRED. BEGIN
JOINT REINFORCING AT THE TOP OF SECOND BLOCK COURSE ABOVE FLOOR SLAB.
C. PROVIDE MASONRY BOND BEAM WITH 2 - D16 AT 1000 mm MAX, BELOW ALL OPENINGS, AND AS OTHERWISE SHOWN ON DRAWINGS. EXTEND 400 mm BEYOND OPENING EDGES.
D. DISCONTINUE BOND BEAM REINFORCEMENT AT CONTROL JOINTS EXCEPT AT FLOOR
AND ROOF LOCATIONS.
E. DISCONTINUE HORIZONTAL JOINT REINFORCEMENT AT CONTROL JOINTS
F. SEE DRAWING SS-509 FOR HORIZONTAL REINFORCEMENT DETAILS AT WALL
INTERSECTIONS AND CORNERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
DESIGN REFERENCES
A. ALL STEEL CONSTRUCTION SHALL BE IN ACCORDANCE WITH AMERICAN INSTITUTE
OF STEEL CONSTRUCTION SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS AISC
360-10.
B. STEEL JOISTS SHALL BE IN ACCORDANCE WITH STEEL JOIST INSTITUTE STANDARD
SPECIFICATIONS FOR JOIST GIRDERS, STEEL JOISTS, AND LONGSPAN STEEL JOISTS
SJI JG 1.1-10, K 1.1-10, AND LH/DLH 1.1-10.
C. STEEL DECK SHALL BE IN ACCORDANCE WITH STEEL DECK INSTITUTE DESIGN
MANUAL FOR COMPOSITE DECKS, FORM DECKS, AND ROOF DECKS SDI
PUBLICATION 31-07.
D. DESIGN AND CONSTRUCTION OF METAL BUILDING SYSTEMS SHALL BE IN
ACCORDANCE WITH METAL BUILDING MANUFACTURERS METAL BUILDING SYSTEMS
MANUAL (MBSM - 2012).
MATERIAL:
W-SHAPES ASTM A992
PLATES AND MISC. SHAPES ASTM A36
HS BOLTS ASTM 325 OR A490
COMMON BOLTS ASTM A307
ROUND PIPES ASTM A53 TYPE E OR S, GRADE B
HOLLOW STRUCTURAL SHAPES ASTM A500, GRADE B
ANCHOR RODS ASTM F1554, GR. 36
WELD ELECTRODES 482 MPa (70 ksi) TENSILE STRENGTH
ALL METAL WORK SHOWN ON DRAWINGS SHALL BE FABRICATED OF STRUCTURAL STEEL
UNLESS OTHERWISE NOTED.
SHOP CONNECTIONS MAY BE BOLTED OR WELDED. ALL FIELD CONNECTIONS SHALL BE
BOLTED UNLESS OTHERWISE SHOWN ON THE DRAWINGS.
ALL BOLTED CONNECTIONS SHALL BE SNUG-TIGHT BEARING TYPE CONNECTIONS MADE
WITH 19 mm (3/4 INCH) BOLTS MEETING THE REQUIREMENTS OF ASTM 325N UNLESS
OTHERWISE NOTED.
ALL WELDING SHALL BE IN ACCORDANCE WITH THE CURRENT AWS, D1.1.
STRUCTURAL WELDING CODE - STEEL.
WHERE WELD SIZE IS NOT CALLED OUT, USE AISC MINIMUM SIZE.
UNLESS OTHERWISE NOTED, BEAM END CONNECTIONS SHALL CONFORM TO AISC
STANDARD. TWO ANGLE WEB CONNECTIONS, WHETHER BOLTED OR WELDED, EACH END
CONNECTION SHALL BE CAPABLE OF SUPPORTING ONE-HALF THE TOTAL UNIFORM LOAD
CAPACITY SHOWN IN THE ALLOWABLE UNIFORM LOAD TABLES. PART II OF THE AISC
MANUAL OF STEEL CONSTRUCTION, HOLE SWILL BE SHORT - SLOTTED IN THE
OUTSTANDING ANGLE LEGS (THOSE CONNECTED TO THE SUPPORTING MEMBER) AND
STANDARD OTHERWISE.
SHAPE WEIGHT N(BOLT/ROW)
(KG) MIN MAX
W610 262-82 4 7 W530 248-66 4 6 W460 213-52 3 5 W360 196-134 3 3 W360 122-64 2 3 W360 58-33 2 4 W310 129-60 2 3 W310 52-21 2 3 W250 167-49 2 2 W250 45-18 2 3 W200 100-36 2 2 W200 31-15 2 2
VALUES OF N ARE BASED ON ROW SPACING OF 75 MILLIMETERS AND AN EDGE DISTANCE
OF 30 MILLIMETERS
STEEL JOISTS, BRIDGING AND OTHER ACCESSORIES SHALL BE DESIGNED FABRICATED
AND ERECTED IN ACCORDANCE WITH SJI SPECIFICATIONS.
JOISTS CALLED OUT ON THE CONTRACT DRAWINGS ARE SIZED FOR UNIFORM GRAVITY
LOADS ONLY AND DO NOT TAKE INTO ACCOUNT ANY ADDITIONAL ROOF SLOPE
REQUIREMENTS. CONTRACTOR SHALL CHECK AND RESIZE JOISTS AS REQUIRED FOR ANY
SPECIAL SLOPE CONDITIONS AND FOR ALL ADDITIONAL WIND AND ROOF LOADS AND
CONCENTRATED LOADS INDICATED ON THE CONTRACT DRAWINGS, OR AS OTHERWISE
PROVIDED BY EQUIPMENT SUPPLIERS. DEPTHS INDICATED SHALL NOT BE CHANGED
WITHOUT THE APPROVAL OF THE CONTRACTING OFFICER.
GROSS UPLIFT PRESSURE FOR JOIST UPLIFT CALCULATION PURPOSES ARE SHOWN ON
THE FACILITY DRAWINGS.
ALL JOIST TOP AND BOTTOM CHORDS SHALL BE CAPABLE OF SUPPORTING IN FLEXURE A
110 kg (250 LB) CONCENTRATED LOAD AT ANY LOCATION BETWEEN PANEL POINTS ALONG
THE TOP AND BOTTOM CHORDS. IN ADDITION TO ALL OTHER LOADS INDICATED OR
SPECIFIED.
UNLESS NOTED OTHERWISE OR EXCEPT AS REQUIRED OTHERWISE BY OTHER
GOVERNING CODES, ALL JOISTS SHALL BE FIELD WELDED TO SUPPORTING MEMBERS.
THESE WELDS SHALL BE SIZED BY THE JOIST MANUFACTURER. PROVIDE A MINIMUM OF
5x40 mm LONG FILLET WELD ON EACH SIDE OF JOIST SEAT.
JOIST SHALL BE INSTALLED TO PROVIDE A FLAT PLANE FOR ROOFING ATTACHMENT.
FIELD JOIST MODIFICATIONS AND SHIMS SHALL BE PROVIDED AS REQUIRED AND SHALL
BE APPROVED BY THE CONTRACTING OFFICER.
JOIST DEFLECTION SHALL NOT EXCEED 1/240 OF THE SPAN DUE TO TOTAL LOAD NOR
1/360 OF THE SPAN DUE TO LIVE LOAD.
IN ADDITION TO UPLIFT AND REACTION LOADS, JOIST BRIDGING SHALL ALSO BE SIZED TO
HANDLE THE LATERAL COMPONENT OF THE INCLINED JOIST GRAVITY LOADS.
STRUCTURAL STEEL NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
1. METAL BUILDING SYSTEM (MBS) SHALL BE DESIGNED,
FABRICATED, AND INSTALLED IN ACCORDANCE WITH METAL
BUILDING MANUFACTURERS ASSOCIATION "METAL BUILDING
SYSTEM MANUAL" (MBSM - 2012)
2. OUT-TO-OUT BUILDING DIMENSIONS SHOWN ARE MINIMUMS. THE
CONTRACTOR SHALL COORDINATE COLUMN, BASE PLATE, ANCHOR
BOLT AND FOUNDATIONS TO SUIT THE SELECTED METAL BUILDING
SYSTEM.
3. REFER TO ARCHITECTURAL DRAWINGS FOR BUILDING SIZE AND
OTHER REQUIREMENTS. REFER TO THE CONTRACT
SPECIFICATIONS SECTION 13 34 19 FOR ADDITIONAL DESIGN AND
CONSTRUCTION REQUIREMENTS.
4. UNLESS OTHERWISE NOTED, MBS SHALL BE DESIGNED NOT TO
EXCEED THE FOLLOWING DEFLECTION AND DRIFT LIMITS:
A. ROOF FRAMING: SPAN/240
B. WALL FRAMING: SPAN/240
C. FRAME DRIFT: EAVE HEIGHT/200
5. THE CONTRACTOR SHALL DESIGN THE FOUNDATIONS FOR THE MBS
INCLUDING FOOTINGS, TIE BEAMS, PIERS, BASE PLATES, ANCHOR
BOLTS AND ANCHOR BOLT EMBEDMENT AND SHALL SUBMIT SHOP
DRAWINGS WITH COMPLETE DESIGN CALCULATIONS FOR THE MBS
FOUNDATION DESIGN. THE DESIGN SHALL BE BASED ON A
GEOTECHNICAL INVESTIGATION AS REQUIRED IN THE SCOPE OF
WORK.
6. MBS SHALL BE DESIGNED TO SUPPORT CRANE TO BE SIZED IN
ACCORDANCE WITH THE SPECIFICATION AND LOCATED AS
INDICATED ON ARCHITECTURAL DRAWINGS.
7. DESIGN SHALL BE IN ACCORDANCE WITH UFC 4-440-01
WAREHOUSE AND STORAGE FACILITIES.
8. MBS SHALL BE DESIGNED AND DETAILED TO LATERALLY SUPPORT
CMU WALLS EXTERIOR AND INTERIOR.
METAL BUILDING SYSTEM NOTES
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
B
C
D
2 3 4 5 1/
/2
1:
:1
P M
1/
/2
1:
:1
PM
A
IR
D
EF
E N
SE
IM
PO
RO
V E
M
EN
TS
-0 7-
MIDDLE EAST DISTRICT
JM
G
JM
G
JE
FF
ER
Y
P . R
AN
EY
, C H
EI
F
A C
H
IT
EC
TU
R
AL
B R
AN
C
H
S S0
G
N
SS-004
W
IN
C H
E
ST
E R
, V A
R
LT
ST
R U
C
TU
R
AL
S
TE
E L A
N D
M
ET
A L
B
UI
LD
IN
G S
YS
TE
M N
O
TE
S
P2 -4
U
N
SP
EC
IF
IE
D
L O
C A T
IO
N
ST
AN
D
AR
DS
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
13 mm ISOLATION
JOINT ALL SIDES
BUILDING
COLUMN OR PIER
FLOOR SLAB
JOINT, SEE PLAN
ADD 1-D14 MID DEPTH
OF SLAB, TYP
m m m m
STND LAP, TYP
350 500
4-D14 CONT BOT DISTRIBUTED
ACROSS THICKENED SLAB, TYP UNO
D14 @300, TYP UNO150 CAPILLARY WATER BARRIER, TYP
VAPOR RETARDER, SEE SPECS
TYP SLAB, SEE PLAN
WALL DOWELS, D16 @1200 TYP UNO
CMU WALL, SEE PLAN
M
IN
. T
YP
CJ OR CIJ, SEE
DETAILS THIS
SHEET
STND LAP, TYP
450 450
4-D14 CONT BOT DISTRIBUTED
ACROSS THICKENED SLAB, TYP UNO
D14 @300, TYP UNO150 CAPILLARY WATER BARRIER, TYP
VAPOR RETARDER, SEE SPECS
TYP SLAB, SEE PLAN
WALL DOWELS, D16 @1200 TYP UNO
CMU WALL, SEE PLAN
M
IN
. T
YP
T, S
E E
P
LA
N
T/ 2 40
T
YP
75 TYP
BACKER ROD AND
SEALANT AS REQUIRED,
SEE ARCH DWGS
6 mm TOOLED, OR
FORMED JOUNT, TYP
D25 X 400 SMOOTH BAR @ 300, PAINT
AND GREASE ONE END, PLACE NO
CLOSER THAN 300 FROM ANY JOINT
INTERSECTION, TYP
SLAB CONSTRUCTION JOINT (CJ)
CONSTRUCTION JOINT
SEE DETAIL THIS SHEET
13 mm EXPANSION JOINT
FILLER, TYP
WALL OR GRADE BEAM
T, S
E E
P
LA
N
T/
T/
TY
P
75 TYP
BACKER ROD AND
SEALANT AS REQUIRED,
SEE ARCH DWGS
6 mm SAW-CUT, TOOLED, OR
FORMED JOUNT, TYP
D25 X 400 SMOOTH BAR @ 300, PAINT
AND GREASE ONE END, PLACE NO
CLOSER THAN 300 FROM ANY JOINT
INTERSECTION, TYP
COORD W/ ARCH DWGS
200 SLAB REINF
WITH D14 @
300 O.C. E.W.
TOP ONLY
INTERIOR SLAB,
SEE PLAN (TYP)
ISOLATION
JOINT
SLOPE AS
REQUIRED, SEE
ARCH DWGS
DOOR OPNG
SS-501
7 Sim
WALL OR COLUMN
BACKER ROD AND SEALANT AS
REQUIRED, SEE ARCH DWGS
13 mm JOINT
FILLER MATERIAL
P
LA
N
S
EE
SEE PLAN FOR SLAB SIZE
AND REINFORCEMENT
SLAB REINFORCEMENT TO BE
CONTINUED AROUND
THICKENED EDGE (TYP.)
VAPOR BARRIER (TYP.)
100 CAPILLARY WATER
BARRIER (TYP.)
1 MIN.
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5 1/
/2
1:
:1
P M
1/
/2
1:
:1
PM
A
IR
D
EF
E N
SE
IM
PO
RO
V E
M
EN
TS
-0 7-
MIDDLE EAST DISTRICT
JM
G
JM
G
JE
FF
ER
Y
P . R
AN
EY
, C H
EI
F
A C
H
IT
EC
TU
R
AL
B R
AN
C
H
S S5
D
T
SS-501
W
IN
C H
E
ST
E R
, V A
R
LT
SL
AB
-O N
-G
RA
D E
DE
TA
IL
S
P2 -4
U
N
SP
EC
IF
IE
D
L O
C A T
IO
N
ST
AN
D
AR
DS
NTS
COLUMN ISOLATION JOINT6
NTS
TYPICAL THICKENED FLOOR SLAB UNDER
CMU WALL AT FLOOR JOINTS2 NTS
TYPICAL THICKENED FLOOR SLAB UNDER
CMU WALL NOT AT FLOOR JOINTS5
NTS
SLAB CONSTRUCTION JOINT (CJ)4 NTS
CONSTRUCTION JOINT AT INTERIOR
GRADE BEAM/STEM
WALL/DOORWAY/STOOP7NTS
SLAB CRACK CONTROL JOINT (CIJ)1
NTS
STOOP DETAIL8
NTS
TYIPCAL SLAB ISOLATION JOINT (IJ)3
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
N.T.S.
TYPICAL THICKENED SLAB EDGE9
ISOLATION JOINT (TYP)
SLAB, SEE PLAN
CONC. FOUND
WALL (TYP)
CONC WALL FTG,
(TYP)
T/FTG
T/SLAB, VARIES
SEE PLAN
H
EI
G H
T
WIDTH
SEE SCH
FOR REINF
SEE SCH FOR REINF
D16 @ 250 MAX,
E.F. (TYP)
FULLY GROUTED 200
CMU WALL, REINF PER
MASONRY NOTES
M
AS
O N
R Y
N O
TE
S
LA
P
PE
R
D16 @ 400 MAX,
E.F. (TYP)
T/CONC
STEM WALL
[0.00]
EXPANSION JOINT MATERAL
WITH SEALNT AT TOP
FINISH GRADE
SEE FOUNDATION PLAN
FOR GROUND FLOOR
SLAB REINFORCING
T/FTG
T/SLAB
SEE COLUMN SCHEDULE FOR
REINFORCEMENT AND DOWELS
TIES AROUND DOWELS
CONTINUE INTO
FOOTING BASE (TYP)
LONGITUDINAL
REINFORCEMENT,
SEE FOOTING
SCHEDULE FOR
NUMBER AND SIZE
M
AX
SP
A C
E S
D
T
IE
S
(SLAB MAY BE ON ALL
FOUR SIDES FOR
INTERIOR COLUMNS)
STANDARD HOOK
T 75 C
LR
TRANSVERSE
REINFORCEMENT,
SEE FOOTING
SCHEDULE FOR
SIZE AND SPACING
B
OF SYMMETRY
EQ EQ
EXPANSION JOINT MATERAL
WITH SEALNT AT TOP (TYP)
SEE FOUNDATION PLAN
FOR GROUND FLOOR
SLAB REINFORCING
T/FTG
T/SLAB
TIES AROUND DOWELS
CONTINUE INTO
FOOTING BASE (TYP)
LONGITUDINAL
REINFORCEMENT,
SEE FOOTING
SCHEDULE FOR
NUMBER AND SIZE
(SLAB MAY BE ON ALL
FOUR SIDES FOR
INTERIOR COLUMNS)
STANDARD HOOK
C
LR
TRANSVERSE
REINFORCEMENT,
SEE FOOTING
SCHEDULE FOR
SIZE AND SPACING
B
OF SYMMETRY
EQ EQ
SEE COLUMN SCHEDULE FOR
REINFORCEMENT AND
DOWELS
(T Y
P)
SP
A C
E S
D
T
IE
S
EXPANSION JOINT MATERAL
ISOLATION JOINT (TYP)
SLAB, SEE PLAN
CONC. FOUND
WALL (TYP)
CONC WALL FTG,
(TYP)
T/FTG
T/SLAB
H
EI
G H
T
WIDTH
SEE SCH
FOR REINF
SEE SCH FOR REINF
D16 @ 275 MAX,
E.F. (TYP)
250 CONCRETE WALL, SEE
PLAN FOR REINFORCEMENT
D16 @ 450 MAX,
E.F. (TYP)
EFIS (TYP)
ISOLATION JOINT (TYP)
SLAB, SEE PLAN
CONC. FOUND
WALL (TYP)
CONC WALL FTG,
(TYP)
T/FTG
T/SLAB, VARIES
SEE PLAN
H
EI
G H
T
WIDTH
SEE SCH
FOR REINF
SEE SCH FOR REINF
D16 @ 250 MAX,
E.F. (TYP)
250 CONCRETE WALL, SEE
PLAN FOR REINFORCEMENT
D16 @ 400 MAX,
E.F. (TYP)
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5 1/
/2
1:
:2
P M
1/
/2
1:
:2
PM
A
IR
D
EF
E N
SE
IM
PO
RO
V E
M
EN
TS
-0 7-
MIDDLE EAST DISTRICT
JM
G
JM
G
JE
FF
ER
Y
P . R
AN
EY
, C H
EI
F
A C
H
IT
EC
TU
R
AL
B R
AN
C
H
S S5
D
T
SS-502
W
IN
C H
E
ST
E R
, V A
R
LT
C O
N C
RE
T E
F O
U N
D
AT
IO
N
D
ET
A
IL
S
P2 -4
U
N
SP
EC
IF
IE
D
L O
C A T
IO
N
ST
AN
D
AR
DS
N.T.S.
TYPICAL CMU WALL FOOTING4
NTS
TYPICAL COLUMN FOOTING1
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
NTS
COMBINED CONCRETE FOOTING DETAIL2
N.T.S.
CONCRETE WALL FOOTING FOR EXT
CONCRETE WALL WITH EFIS3A
N.T.S.
CONCRETE WALL FOOTING FOR EXT
CONCRETE WALL WITH VENEER3B
NOTES:
1. FOR LAP LENGTH SEE SPLICE NOTES ON SHEET S-002.
2. CONTRACTING OFFICER APPROVAL IS REQUIRED PRIOR
TO CONSTRUCTING CONSTRUCTION JOINTS IN BEAMS.
COORDINATE LOCATION WITH DETAIL 2, SHEET SS-505.
CONSTRUCTION JOINT (TYP) TYPICAL BEAM REINFORCEMENT
TYPICAL REINFORCEMENT TIES
25 CLEAR (TYP)
EQ
EQ
EQ
L1/4*
END HOOPS
50 mm
LAP SPLICE WHEN REQ'D
AT CENTER SPAN OF BEAM
SEE SS-504 FOR
TYP COLUMN
REINF DETAILS
SEE SCHEDULE
INTERMEDIATE STIR.
L1/4*
END HOOPS
50 mm
STD. 90
DEGREE
HOOK, TYP.
SEE SS-002
L1 L2
SEE SCH. FOR
TOP REINF
SEE SCH. FOR
BOTTOM REINF
H
L2/4*
END HOOPS
50 mm
LAP SPLICE WHEN REQ'D
AT CENTER SPAN OF BEAM
SEE SCHEDULE
INTERMEDIATE STIR.
L2/4*
END HOOPS
50 mm
SEE SCH. FOR
TOP REINF
SEE SCH. FOR
BOTTOM REINF
LEFT RIGHT
C
LR
, T
YP
C
LR
, T
YP
GRID NUMBER OR LETTER
COLD JOINT (TYP)
TYPE A TYPE B TYPE C TYPE D TYPE E TYPE F
CROSS-TIE, TYP
NOTE: CONSECUTIVE CROSS-TIES
ENGAGING THE SAME LONGITUDINAL
BAR SHALL HAVE 90-DEGREE HOOKS
ON OPPOSITE SIDES OF BEAM, TYP
SCH. TOP REINF.
SCH. BOT REINF.
SCH. STIRRUP
INTERMEDIATE SEISMIC
STIRRUPS END SEISMIC HOOPS
NOTE: FLOOR SLABS ARE NOT SHOWN IN BEAM SECTIONS
SEISMIC HOOP, TYP
SINGLE PIECE TWO PIECES
ALTERNATIVE
135 DEGREE HOOKS
w/ 6 db EXTENSION
SEE SS-002 90 DEGREE SEISMIC HOOK
w/ 6 db EXTENSION, SEE SS-002
CROSS-TIE
NOTE: CONSECUTIVE CROSS-TIES
SHALL HAVE 90 DEGREE HOOKS ON
OPPOSITE SIDES.
BOTTOM BARS, SEE BEAM
REINF SCHEDULE FOR TYPE
TOP FLEX. REINF, UPPER
SEE S-600 SERIES FOR SCH.
SEE PLANS FOR SLAB
THICKNESS AND REINF
20 mm CHAMFER
(TYP AT EXPOSED CORNERS)
SC
H
. D
EP
TH
TOP FLEX. REINF, LOWER
SEE S-600 SERIES FOR SCH.
SCH. WIDTH
TORSION REINF, WHERE REQUIRED
SEE BEAM REINF SCHEDULE
1. ALL TENSION LAP SPLICES IN BEAMS SHALL BE CLASS B. SEE
SS-002
2. REFER TO BEAM SCHEDULE FOR SIZE OF BEAMS AND
REINFORCEMENT STEEL NOT SHOWN.
3. *: OR 2H, WHICHEVER IS GREATER (H = BEAM DEPTH OF
INDIVIDUAL SPAN). UNLESS NOTED OTHERWISE, HOOPS SHALL
BE SAME SIZE AS STIRRUPS AND BE SPACED AT 75 mm MAX.
4. FOR PROPER BEAM ORIENTATIONS ELEVATIONS SHALL BE
VIEWED WITH NUMBERS INCREASING FROM LEFT TO RIGHT
AND WITH LETTERS INCREASING FROM RIGHT TO LEFT.
TYPICAL ROOF SLAB
REINFORCEMENT
BEAM REINFORCEMENT
NOT SHOWN FOR CLARITY
B.O. BEAM
[SEE SCHEDULE]
P
LA
N
S
EE
MIN.
Ø14 @ 450 O.C. (TYP.)
SEE PLAN FOR
ROOF SLAB
REINFORCEMENT
ROUGHEN SURFACE
BEAM REINFORCEMENT
NOT SHOWN FOR CLARITY
(SEE BEAM SCHEDULES)
B.O. BEAM ELEV.
SEE SCHEDULE
H
EI
G H
T
N O
M
IN
A L
BE
AM
S E
E
PL
AN
MIN.
T.O. PARAPET
ELEV. SEE PLAN
Ø14 @ 300 O.C. (TYP.)
COORDINATE PLACEMENT OF
BOTTOM REINFORCEMENT
WITH LOCATION OF SCUPPERS
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .