AM_3_VOLUME_3_DRAWING.pdf
PDF 3 MB Posted
- Attached to
- Kuwait Air Defense Improvements Federal contract opportunity
- Solicitation number
- W912ER-16-R-0008
About this file
Volume 3 Drawing Changes
View the file
Other files for this federal contract opportunity
Show all 50
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
B
C
D
2 3 4 5 7/
/2
1:
:3
P M
7/
/2
1:
:3
PM
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
Enter District
EM
S
G W
D
R O
B
ER
T L.
F O
X , P
E
-G
I0
G N
G-014
JA
R
IN
D
EX
O
F
DR
A W
IN
G
S
VO
LU
M
E
SH
EE
T
P2 -4
G
EN
ER
A
L
443309-SITE DESIGN 07-ALS
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
CIVIL
C-000 443309--CS000-7LS SITE 7 GRAPHIC REPRESENTATIONS
C-001 443309--CS001-7LS PROJECT LOCATION AND VICINITY MAP
C-002 443309--CS002-7LS SITE 7 - ALS OVERALL SITE PLAN
C-003 443309--CS003-7LS LAYDOWN AND HAUL ROUTE PLAN
C-004 443309--CS004-7GN ABBREVIATIONS SYMBOLS AND LEGENDS
C-100 443309--CD100-7PN DEMOLITION PLAN
C-101 443309--CS101-7LS ENLARGED OVERALL SITE PLAN
C-101A 443309--CS101A-7LS ALS SITE 07 OVERALL SITE PLAN OPTIONAL BID ITEMS
C-102 443309--CS102-7PN03 3 AM#3 ENLARGED SITE PLAN
C-103 443309--CS103-7PN ENLARGED SITE PLAN
C-104 443309--CS104-7PN ENLARGED SITE PLAN
C-105 443309--CS105-7PN ENLARGED SITE PLAN
C-106 443309--CS106-7PN ENLARGED SITE PLAN
C-107 443309--CS107-7PN ENLARGED SITE PLAN
C-401 443309--CU401-7PN UTILITY PLAN
C-402 443309--CU402-7PN UTILITY PLAN
C-501 443309--CU501-7DT SANITARY SEWER HOLDING TANK DETAILS
C-502 443309--CU502-7DT LEACH FIELD ENLARGED PLAN
C-503 443309--CU503-7DT LEACH FIELD AND SEPTIC TANK DETAILS
C-504 443309--CU504-7DT LEACH FIELD DETAILS
C-505 443309--CU505-7DT UTILITY DETAILS
C-506 443309--CU506-7DT UTILITY DETAILS CONCRETE ANCHORS
C-511 443309--CS511-7DT EQUIPMENT PAD DETAILS
C-512 443309--CS512-7DT STORAGE FACILITY DETAILS
C-513 443309--CS513-7DT DUNPSTER PAD AND ENCLOSURE DETAILS
C-514 443309--CS514-7DT03 3 AM#3 PAVEMENT DETAILS
C-515 443309--CS515-7DT RADAR EXCLUSION ZONE DETAILS
C-516 443309--CS516-7DT OPTIONAL BERM AND DITCH DETAILS
C-521 443309--CS521-7DT CHAIN LINK SECURITY FENCE DETAILS
C-522 443309--CS522-7DT03 3 AM#3 CHAIN LINK SECURITY FENCE DETAILS
C-523 443309--CS523-7DT CHAIN LINK SECURITY FENCE DETAILS
C-531 443309--CS531-7DT JERSEY BARRIER DETAILS
C-532 443309--CS532-7DT ALASKA BARRIER DETAILS
C-533 443309--CS533-7DT INTERLOCKING ALASKA BARRIER DETAILS
C-541 443309--CS541-7DT03 3 AM#3 CANTILEVERED SLIDING GATE PLAN AND ELEVATION
C-542 443309--CS542-7DT CANTILEVERED SLIDING GATE SECTIONS
C-543 443309--CS543-7DT CANTILEVERED SLIDING GATE DETAILS
SITE ELECTRICAL
XE-101 443309-SITE07--XE101PN SITE ELECTRICAL POWER
XE-102 443309-SITE07--XE102PN SITE ELECTRICAL POWER
XE-103 443309-SITE07--XE103PN SITE ELECTRICAL LIGHTING
XE-104 443309-SITE07--XE104PN SITE ELECTRICAL LIGHTING
XE-501 443309-SITE07--XE501DT ELECTRICAL DUCKBANK DETAIL
XE-502 443309-SITE07--XE502DT ELECTRICAL PULLBOX DETAIL
XE-601 443309-SITE07--XE601DI03 3 AM#3 SINGLE LINE DIAGRAM
SITE TELECOMMUNICATIONS
XT-101 443309-SITE07--XT101PN SITE TELECOMMUNICATIONS
XT-102 443309-SITE07--XT102PN SITE TELECOMMUNICATIONS
XT-103 443309-SITE07--XT103PN SITE TELECOMMUNICATIONS
XT-104 443309-SITE07--XT104PN SITE TELECOMMUNICATIONS
XT-501 443309-SITE07--XT501DT MANHOLE WALL DETAIL 1
XT-502 443309-SITE07--XT502DT MANHOLE WALL DETAIL 2
XT-503 443309-SITE07--XT503DT COMMUNICATIONS DETAIL ECC SIPR NET RACK
XT-504 443309-SITE07--XT504DT DUCT BANK DETAIL 1
XT-505 443309-SITE07--XT505DT DUCT BANK DETAIL 2
XT-506 443309-SITE07--XT506DT DUCT BANK DETAIL 3
XT-507 443309-SITE07--XT507DT DUCT BANK DETAIL 4
XT-508 443309-SITE07--XT508DT CABLE LADDER DETAIL
XT-509 443309-SITE07--XT509DT MANHOLE HANDWIRE DETAILS
XT-510 443309-SITE07--XT510DT HANDHOLE COVER DETAILS
XT-511 443309-SITE07--XT511DT MANHOLE DETAILS
XT-512 443309-SITE07--XT512DT MANHOLE TO DUCTBANK CONNECTION DETAIL
XT-513 443309-SITE07--XT513DT CABLE RACKING DIAGRAMS 1
XT-514 443309-SITE07--XT514DT CABLE RACKING DIAGRAMS 2
XT-515 443309-SITE07--XT515DT CABLE RACKING DIAGRAMS 3
XT-516 443309-SITE07--XT516DT CABLE RACKING DIAGRAMS 4
XT-517 443309-SITE07--XT517DT CABLE RACKING DIAGRAMS 5
XT-518 443309-SITE07--XT518DT CABLE RACKING DIAGRAMS 6
XT-519 443309-SITE07--XT519DT CABLE RACKING DIAGRAMS 7
XT-520 443309-SITE07--XT520DT CABLE RACKING DIAGRAMS 8
XT-521 443309-SITE07--XT521DT LAUNCHER HANDHOLE SITE DETAILS
XT-522 443309-SITE07--XT522DT EQUIPMENT PAD HANDHOLE LOCATION
XT-601 443309-SITE07--XT601DI SITE COMMUNICATIONS ONE LINE DIAGRAM
GENERAL VOLUME 3
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
GENERAL
G-002 450031-GI002GN COVER SHEET VOLUME 3 OF 4
G-004 450031-GI004GN INDEX OF VOLUMES
G-014 443309-GI014GN03 3 AM#3 INDEX OF DRAWINGS VOLUME 3 SHEET 1
G-015 443309-GI015GN03 3 AM#3 INDEX OF DRAWINGS VOLUME 3 SHEET 2
G-021 443309-GI021GN STANDARD LEGENDS AND SYMBOLOGY
G-031 443309-GI031GN STANDARD ABBREVIATIONS
INDEX OF DRAWINGS
443309A - ENGAGEMENT CONTROL STATION - SITE 07
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-111 443309A-SB111PN COMPOSITE FOUNDATION PLAN
S-112 443309A-SB112PN PARTIAL FOUNDATION PLAN - WEST
S-113 443309A-SB113PN PARTIAL FOUNDATION PLAN - CENTER
S-114 443309A-SB114PN PARTIAL FOUNDATION PLAN - EAST
S-115 443309A-SB115PN COMPOSITE ROOF FRAMING PLAN
S-116 443309A-SB116PN PARTIAL ROOF FRAMING PLAN - WEST
S-117 443309A-SB117PN PARTIAL ROOF FRAMING PLAN - CENTER
S-118 443309A-SB118PN ROOF FRAMING PLAN
S-119 443309A-SB119PN PARTIAL ROOF FRAMING PLAN - EAST
S-411 443309A-SF411PN ENLARGED STRUCTURAL PLANS
S-501 443309A-SB501DT STRUCTURAL DETAILS
S-502 443309A-SB502DT STRUCTURAL DETAILS
S-503 443309A-SB503DT STRUCTURAL DETAILS
S-611 443309A-SF611SC SCHEDULES
ARCHITECTURAL
A-011 443309A-AE011PN LIFE SAFETY & AIR BARRIER PLANS
A-111 443309A-AE111PN FLOOR PLAN
A-112 443309A-AE112PN ROOF PLAN
A-211 443309A-AE211EL NORTH SOUTH ELEVATIONS
A-212 443309A-AE212EL WEST EAST ELEVATIONS
A-311 443309A-AE311SE SECTIONS
A-312 443309A-AE312SE SECTIONS
A-313 443309A-AE312SE RAMP SECTION
A-314 443309A-AE313SE WALL SECTIONS
A-411 443309A-AE411LS ENLARGED FLOOR PLAN
A-413 443309A-AE413LS REFLECTED CEILING PLAN
A-415 443309A-AE415LS ENLARGED TOILET PLAN
A-416 443309A-AE416EL SCREEN ROOM
A-511 443309A-AE511DT DETAILS
A-611 443309A-AE610SC DOOR AND FINISH SCHEDULES
PLUMBING
P-111 443309A-PL111PN GROUND FLOOR PLUMBING PLAN - SITE 07
P-112 443309A-PL112PN ROOF PLUMBING PLAN - SITE 07
P-411 443309A-PL411LS ENLARGED PLUMBING PLAN - SITE 07
P-911 443309A-PL911DI RISER DIAGRAMS - SITE 07
MECHANICAL
M-111 443309A-MH111PN GROUND FLOOR HVAC PLAN - SITE 07
M-411 443309A-MH411LS ENLARGED HVAC FLOOR PLAN - SITE 07
M-412 443309A-MH412LS ENLARGED TOILET ROOM PLAN - SITE 07
M-511 443309A-MH511DT FUEL TANK LAYOUT - SITE 07
M-611 443309A-MH611SC MECHANICAL SCHEDULES - SITE 07
ELECTRICAL
E-111 443309A-EP111PN POWER PLAN - AREA "A" - SITE 7 ALS
E-112 443309A-EL112PN LIGHTING PLAN - AREA "A" - SITE 7 ALS
E-113 443309A-EP113PN LIGHTING AND POWER PLAN - RADAR RAMP - SITE 7
E-114 443309A-EP114PN GROUNDING AND LIGHTNING PROTECTION - SITE 7 ALS
E-611 443309A-EP611SC PANEL SCHEDULES - SITE 7
E-612 443309A-EP612SC PANEL SCHEDULE - SITE 7
TELECOMMUNICATIONS
T-111 443309A-TN111PN03 3 AM#3 TELECOMMUNICATIONS GROUND FLOOR PLAN - SITE 7
T-112 443309A-TN112PN03 3 AM#3 TELECOMMUNICATIONS CABLE TRAY PLAN - SITE 7
T-113 443309A-TN113PN03 3 AM#3 TELECOM SECURE VOICE PLAN - SITE 7
T-211 443309A-TN211EL03 3 AM#3 TELECOM ELEVATION DETAILS - SITE 7
T-511 443309A-TN511DT03 3 AM#3 TELECOM RM 108 ENLARGED FLOOR PLAN - SITE 7
T-512 443309A-TN512DT03 3 AM#3 TELECOMMUNICATIONS CABINET DETAILS - SITE 7
443309B - HEADQUARTERS BUILDING - SITE 07
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
A-411 443309B-AE411LS ENLARGED FLOOR PLAN- SITE 07-ALS
A-421 443309B-AE421LS ENLARGED FLOOR PLAN (OPTION) SITE 07-ALS
A-611 443309B-AE611SC DOOR AND WINDOW SCHEDULES-SITE 07- ALS
A-612 443309B-AE612SC FINISH SCHEDULE-SITE 07- ALS
A-621 443309B-AE621SC DOOR AND WINDOW SCHEDULES (OPTION) SITE 07-ALS
A-622 443309B-AE622SC FINISH SCHEDULE (OPTION) SITE 07-ALS
PLUMBING
P-111 443309B-MP101PN SITE 7 DOMESTIC WATER FLOOR PLAN
P-112 443309B-MP102PN SITE 7 SANITARY FLOOR PLAN
P-113 443309B-MP103PN SITE 7 PLUMBING ROOF PLAN
P-121 443309B-MP121PN SITE 7 DOMESTIC WATER FLOOR PLAN (OPT)
P-122 443309B-MP122PN SITE 7 SANITARY FLOOR PLAN (OPT)
P-123 443309B-MP123PN SITE 7 PLUMBING ROOF PLAN (OPT)
P-411 443309B-MP401LS SITE 7 ENLARGED PLUMBING PLANS
P-412 443309B-MP412LS SITE 7 ENLARGED PLUMBING PLANS
P-421 443309B-MP421LS SITE 7 ENLARGED PLUMBING PLANS (OPT)
P-422 443309B-MP422LS SITE 7 ENLARGED PLUMBING PLANS (OPT)
P-423 443309B-MP423LS SITE 7 ENLARGED PLUMBING PLANS (OPT)
P-911 443309B-MP901DI SITE 7 PLUMBING RISER DIAGRAM
P-921 443309B-MP921DI SITE 7 DOMESTIC WATER RISER DIAGRAM (OPT)
P-922 443309B-MP922DI SITE 7 SANITARY RISER DIAGRAM (OPT)
MECHANICAL
M-111 443309B-MH101PN SITE 7 HVAC FLOOR PLAN
M-112 443309B-MH102PN SITE 7 HVAC ROOF PLAN
M-121 443309B-MH121PN SITE 7 HVAC FLOOR PLAN (OPT)
M-122 443309B-MH122PN SITE 7 HVAC ROOF PLAN (OPT)
M-611 443309B-MH601SC SITE 7 HVAC SCHEDULES
M-621 443309B-MH621SC SITE 7 HVAC SCHEDULES (OPT)
ELECTRICAL
E-111 443309B-EP111PN POWER FLOOR PLAN - SITE 7 - ALS
E-112 443309B-EL112PN LIGHTING FLOOR PLAN - SITE 7 - ALS
E-113 443309B-EP113PN ROOF POWER PLAN - SITE 7 - ALS
E-114 443309B-EP114PN GROUNDING PLAN - SITE 7 ALS
E-121 443309B-EP121PN POWER FLOOR PLAN (OPTION) - SITE 7 - ALS
E-122 443309B-EL122PN LIGHTING FLOOR PLAN (OPTION) - SITE 7 - ALS
E-123 443309B-EP123PN ROOF POWER PLAN (OPTION) - SITE 7 - ALS
E-124 443309B-EP124PN GROUNDING PLAN - SITE 7 ALS (OPTION)
E-611 443309B-AE611SC PANEL SCHEDULES - SITE 7 - ALS
E-621 443309B-EP621SC PANEL SCHEDULES (OPTION) - SITE 7 - ALS
E-622 443309B-EP622SC PANEL SCHEDULES (OPTION) - SITE 7 - ALS
TELECOMMUNICATIONS
T-111 443309B-TN111PN03 3 AM#3 TELECOM FLOOR PLAN - SITE 7
T-112 443309B-TN112PN03 3 AM#3 SECURE VOICE FLOOR PLAN - SITE 7
T-121 443309B-TN121PN03 3 AM#3 TELECOM FLOOR PLAN - SITE 7 (OPTION)
T-122 443309B-TN122PN03 3 AM#3 SECURE VOICE FLOOR PLAN - SITE 7 (OPTION)
T-411 443309B-TN411LS03 3 AM#3 ENLARGED TELECOM RM 119 - SITE 7
T-421 443309B-TN421LS03 3 AM#3 ENLARGED TELECOM RM 106E - SITE 7 (OPTION)
T-511 443309B-TN511DT03 3 AM#3 COMM RACK DETAIL - SITE 7
T-521 443309B-TN521DT03 3 AM#3 COMM RACK DETAIL - SITE 7 (OPTION)
443309B - HEADQUARTERS BUILDING - SITE 07
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-111 443309B-SB111PN FOUNDATION AND SLAB PLAN SITE 07-ALS
S-112 443309B-SF112PN ROOF FRAMING PLAN SITE 07-ALS
S-121 443309B-SB121PN FOUNDATION AND SLAB PLAN (OPTION) SITE 07-ALS
S-122 443309B-SF122PN ROOF FRAMING PLAN (OPTION) SITE 07-ALS
S-611 443309B-SF611SC SCHEDULES SITE 07-ALS
S-621 443309B-SF621SC SCHEDULES (OPTION) SITE 07-ALS
ARCHITECTURAL
A-011 443309B-AE011PN LIFE SAFETY PLAN - SITE 7 - ALS
A-012 443309B-AE012PN AIR BARRIER PLAN - SITE 7 - ALS
A-021 443309B-AE021PN LIFE SAFETY PLAN (OPTION) - SITE 7 - ALS
A-022 443309B-AE022PN AIR BARRIER PLAN (OPTION) - SITE 7 - ALS
A-111 443309B-AE111PN FLOOR PLAN - SITE 7 - ALS
A-112 443309B-AE112PN CEILING PLAN - SITE 7 - ALS
A-113 443309B-AE113PN ROOF PLAN - SITE 7 - ALS
A-121 443309B-AE121PN FLOOR PLAN (OPTION) - SITE 7 - ALS
A-122 443309B-AE122PN CEILING PLAN (OPTION) - SITE 7- ALS
A-123 443309B-AE123PN ROOF PLAN (OPTION) - SITE 7 - ALS
A-211 443309B-AE211EL ELEVATIONS - SITE 07 - ALS
A-221 443309B-AE221EL ELEVATION (OPTION) - SITE 7 - ALS
A-311 443309B-AE311SE SECTIONS- SITE 07-ALS
A-321 443309B-AE321SE SECTIONS (OPTION) SITE 07-ALS
443309C - TOILET BUILDING
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309C-SB101PN FOUNDATION AND SLAB PLAN
S-102 443309C-SF102PN ROOF FRAMING PLAN
S-601 443309C-SF601SC SCHEDULES
ARCHITECTURAL
A-001 443309C-AE001PN LIFE SAFETY PLAN
A-002 443309C-AE002PN AIR BARRIER PLAN
A-101 443309C-AE101PN FLOOR AND ROOF PLAN
A-102 443309C-AE102PN REFLECTED CEILING PLAN
A-201 443309C-AE201EL ELEVATIONS
A-301 443309C-AE301SE SECTIONS
A-302 443309C-AE302SE WALL SECTIONS
A-401 443309C-AE401EL INTERIOR ELEVATIONS
A-601 443309C-AE601SC DOOR AND FINISH SCHEDULES
PLUMBING
P-101 443309C-PL101PN GROUND FLOOR PLUMBING PLAN - SANITARY
P-102 443309C-PL102PN GROUND FLOOR PLUMBING PLAN - DOMESTIC WATER
P-103 443309C-PL103PN PLUMBING ROOF PLAN
P-901 443309C-PL901IS PLUMBING RISER DIAGRAM - SANITARY
P-902 443309C-PL902IS PLUMBING RISER - DOMESTIC WATER
MECHANICAL
M-101 443309C-MH101PN GROUND FLOOR HVAC PLAN
ELECTRICAL
E-101 443309C-EP101PN POWER, LIGHTING AND GROUNDING PLAN
E-601 443309C-EP601SC PANEL SCHEDULE
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A M
E N
D M
EN
T
#3
/2 5/
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
B
C
D
2 3 4 5 7/
/2
1:
:3
P M
7/
/2
1:
:3
PM
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
Enter District
EM
S
G W
D
R O
B
ER
T L.
F O
X , P
E
-G
I0
G N
G-015
JA
R
IN
D
EX
O
F
DR
A W
IN
G
S
VO
LU
M
E
SH
EE
T
P2 -4
G
EN
ER
A
L
443309D - GUARD HOUSE
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309D-SB101PN FOUNDATION AND SLAB PLAN
S-102 443309D-SF102PN03 3 AM#3 ROOF FRAMING PLAN
S-401 443309D-SF401DT CONCRETE DETAILS
S-601 443309D-SF601SC03 3 AM#3 SCHEDULES
ARCHITECTURAL
A-001 443309D-AE001PN LIFE SAFETY PLAN
A-002 443309D-AE002PN AIR BARRIER PLAN
A-101 443309D-AE101PN FLOOR PLAN
A-201 443309D-AE201EL ELEVATIONS
A-301 443309D-AE301SE SECTIONS
A-302 443309D-AE302SE WALL SECTIONS
A-401 443309D-AE401LS TOILET PLAN
A-601 443309D-AE601SC DOOR & FINISH SCHEDULES
PLUMBING
P-101 443309D-PL101PN PLUMBING WASTE PLANS
P-102 443309D-PL102PN PLUMBING WATER PLANS
P-301 443309D-PL301SE PLUMBING SECTIONS
P-901 443309D-PL901IS PLUMBING RISER DIAGRAMS
MECHANICAL
M-101 443309D-MH101PN GROUND FLOOR HVAC PLAN
ELECTRICAL
E-101 443309D-EP101PN POWER, LIGTHING AND GROUNDING PLAN
TELECOMMUNICATIONS
T-101 443309D-TN101PN03 3 AM#3 COMMUNICATIONS FLOOR PLAN
T-501 443309D-TN501DT03 3 AM#3 COMM ENTRANCE DETAIL
INDEX OF DRAWINGS
443309E - GUARD TOWER
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309E-SB101PN FOUNDATION AND SLAB PLAN
S-401 443309$-SS507DT MAT FOUNDATION DETAILS
ARCHITECTURAL
A-001 443309E-AE001PN LIFE SAFETY PLAN
A-101 443309E-AE101PN FLOOR AND ROOF PLAN
A-102 443309E-AE102PN REFLECTED CEILING PLAN
A-201 443309E-AE201EL ELEVATIONS
A-301 443309E-AE301SE BUILDING SECTIONS
A-302 443309E-AE302SE STAIR SECTION & DETAILS
A-601 443309E-AE601SC DOOR AND FINISH SCHEDULES
MECHANICAL
M-101 443309E-MH101PN HVAC FLOOR PLAN
ELECTRICAL
E-101 443309E-EP101PN03 3 AM#3 POWER, LIGHTING AND GROUNDING PLAN
TELECOMMUNICATIONS
T-101 443309E-TN101PN03 3 AM#3 TELECOM FLOOR PLAN
T-201 443309E-TN201EL03 3 AM#3 TELECOM EAST ELEVATION
T-202 443309E-TN202EL03 3 AM#3 TELECOM NORTH ELEVATION
443309F - CAR PARKING SHELTER
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309F-SB101PN FOUNDATION AND SLAB PLAN
ARCHITECTURAL
A-101 443309F-AE101PN PLANS
A-201 443309F-AE201EL ELEVATIONS
A-301 443309F-AE301SE SECTIONS
ELECTRICAL
E-101 443309F-EP101PN POWER, LIGHTING AND GROUNDING
443309G - TRUCK PARKING SHELTER
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309G-SB101PN FOUNDATION AND SLAB PLAN
ARCHITECTURAL
A-101 443309G-AE101PN FLOOR PLAN
A-102 443309G-AE102PN ROOF PLAN
A-103 443309G-AE103PN REFLECTED CEILING PLAN
A-201 443309G-AE201EL ELEVATIONS
A-202 443309G-AE202EL ELEVATIONS
A-301 443309G-AE301SE BUILDING SECTIONS
ELECTRICAL
E-101 443309G-EP101PN POWER, LIGHTING AND GROUNDING PLAN
443309H - STORAGE FACILITY
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309H-SB101PN FOUNDATION AND SLAB PLAN
ARCHITECTURAL
A-101 443309H-AE101PN FLOOR PLAN
A-102 443309H-AE102PN ROOF PLAN
A-103 443309H-AE103PN REFLECTED CEILING PLAN
A-201 443309H-AE201EL ELEVATIONS
A-202 443309H-AE202EL ELEVATIONS
A-301 443309H-AE301SE BUILDING SECTIONS
ELECTRICAL
E-101 443309H-EP101PN LIGHTING, POWER, GROUNDING AND LIGHTNING
PROTECTION PLANS
443309I - FREQUENCY CONVERTER - PDU SHELTER
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309I-SB101PN FOUNDATION AND SLAB PLAN
S-102 443309I-SF102PN ROOF FRAMING PLAN
S-601 443309I-SB601SC SCHEDULES
ARCHITECTURAL
A-001 443309I-AE001PN LIFE SAFETY PLAN
A-002 443309-AE002PN AIR BARRIER PLAN
A-101 443309I-AE101PN FLOOR PLAN
A-201 443309I-AE201EL ELEVATIONS
A-301 443309I-AE301SE SECTIONS
A-601 443309I-AE601SC DOOR AND FINISH SCHEDULES
MECHANICAL
M-101 443309I-MH101PN HVAC FLOOR PLAN
ELECTRICAL
E-101 443309I-EP101PN POWER, LIGHTING AND GROUNDING PLAN
E-601 443309I-EP601SC PANEL SCHEDULES
E-602 443309I-EP602SC PANEL SCHEDULES
443309M - PRAYER/GATHERING BUILDING
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
MECHANICAL
M-101 443309M-MH101PN GROUND FLOOR HVAC PLAN
M-102 443309M-MH102PN ROOF HVAC PLAN
ELECTRICAL
E-101 443309M-EP101PN POWER PLAN
E-601 443309M-EP601SC PANEL SCHEDULE
TELECOMMUNICATIONS
T-101 443309M-TN101PN03 3 AM#3 COMMUNICATIONS FLOOR PLAN
T-501 443309M-TN501PN 6 PAIR PROTECTIVE ENTRANCE TERMINAL (PET)
443309M - PRAYER/GATHERING BUILDING
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309M-SB101PN FOUNDATION AND SLAB PLAN
S-102 443309M-SF102PN ROOF FRAMING PLAN
S-601 443309M-SF601SC SCHEDULES
ARCHITECTURAL
A-001 443309M-AE001PN LIFE SAFETY PLAN
A-002 443309M-AE002PN AIR BARRIER PLAN
A-101 443309M-AE101PN GROUND FLOOR PLAN
A-102 443309M-AE102PN ROOF PLAN
A-103 443309M-AE103PN REFLECTED CEILING PLAN
A-201 443309M-AE201EL ELEVATIONS
A-301 443309M-AE301SE SECTIONS
A-302 443309M-AE302SE WALL SECTIONS
A-501 443309M-AE501DT DETAILS
A-502 443309M-AE502DT DETAILS
A-601 443309M-AE601SC DOOR, WINDOW AND FINISH SCHEDULES
443309N - FUEL DISPENSING SUNSHADE
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309N-SB101PN FOUNDATION AND SLAB PLAN
ARCHITECTURAL
A-101 443309N-AE101PN PLANS
A-201 443309N-AE201EL ELEVATIONS
A-301 443309N-AE301SE SECTIONS
MECHICANICAL
M-101 443309N-MH101PN MECHANICAL PLAN
M-102 443309N-MH102PN FUEL TANK LAYOUT
M-301 443309N-M301SE MECHANICAL SECTION
M-501 443309N-MH501DT FUEL TANK LAYOUT
ELECTRICAL
E-101 443309N-EP101PN LIGHTING, POWER PLAN AND GROUNDING
443309P - MAINTENANCE HIGH-BAY
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309P-SB101PN FOUNDATION AND SLAB PLAN
S-102 443309P-SF102PN BRIDGE CRANE SUPPORT SYSTEM PLAN
S-401 443309P-SB401DT MASONRY AND MBS FOUNDATION DETAILS
S-601 443309P-SB601SC SCHEDULES
ARCHITECTURAL
A-001 443309P-AE001PN LIFE SAFETY PLAN
A-002 443309P-AE002PN AIR BARRIER PLAN
A-101 443309P-AE101PN FLOOR PLAN
A-102 443309P-AE102PN ROOF PLAN
A-103 443309P-AE103PN REFLECTED CEILING PLAN
A-201 443309P-AE201EL ELEVATIONS
A-301 443309P-AE301SE BUILDING SECTIONS
A-302 443309P-AE301SE WALL SECTIONS
A-601 443309P-AE601SC DOOR AND FINISH SCHEDULES
PLUMBING
P-101 443309P-PL101PN GROUND FLOOR PLUMBING PLAN
MECHANICAL
M-101 443309P-MH101PN GROUND FLOOR HVAC PLAN
ELECTRICAL
E-101 443309P-EP101PN GROUNDING AND POWER PLAN
E-102 443309P-EL102PN LIGHTING PLAN
E-601 443309P-EP601SC PANEL SCHEDULE
443309N2 - FUEL TRUCK PARKING SUNSHADE
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309N2-SB101PN FOUNDATION AND SLAB PLAN
ARCHITECTURAL
A-101 443309N2-AE101PN PLANS
A-201 443309N2-AE201EL ELEVATIONS
A-301 443309N2-AE301SE SECTIONS
ELECTRICAL
E-101 443309N2-EP101PN LIGHTING, POWER PLAN AND GROUNDING
443309O - EQUIPMENT PADS
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
ELECTRICAL
E-101 443309O-EP101PN POWER AND GROUNDING PLAN
443309L - POWER PLANT FACILITY - SITE 07
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309L-SB101PN FOUNDATION & ROOF FRAMING PLAN
S-601 443309L-SF601SC SCHEDULES
ARCHITECTURAL
A-001 443309L-AE001PN LIFE SAFETY PLAN
A-002 443309L-A002PN AIR BARRIER PLAN
A-101 443309L-AE101PN FLOOR PLAN
A-102 443309L-AE102PN REFLECTED CEILING PLAN
A-201 443309L-AE201EL ELEVATIONS
A-301 443309L-AE301SE BUILDING SECTIONS
A-601 443309L-AE601SC DOOR & FINISH SCHEDULES
MECHANICAL
M-101 443309L-M101PN GROUND FLOOR HVAC PLAN
ELECTRICAL
E-101 443309L-EP101PN GROUNDING, POWER AND LIGHTING PLAN
E-611 443309L-EP611SC PANEL SCHEDULES - SITE 7
E-612 443309L-EP612SC PANEL SCHEDULES - SITE 7
TELECOMMUNICATIONS
T-101 443309L-TN101PN03 3 AM#3 COMMUNICATIONS FLOOR PLAN
T-501 443309L-TN502DT03 3 AM#3 COMM ENTRANCE & CABINET DETAIL
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A M
E N
D M
EN
T
#3
/2 5/
Y=3246267.89
X=742792.58
0+000.000
POB
BUILDING
PRAYER
BUILDING
HEADQUARTERS
BUILDING
TOILET
AREA
GATHERING
TRUCK PARKING
FUEL TANKER
PARKING
COVERED TRUCK
P L A
N T
P O
W E
R
AND SUNSHADE
FUEL STORAGE TANK
GATEHOUSE
TANK
HOLDING
SEW
AGE
COMMUNICATION TOW
ER
ECS
ALASKA BARRIER
EQUIPMENT PAD W
ITH
ALASKA BARRIER
EQUIPMENT PAD W
ITH
ALASKA BARRIER
EQUIPMENT PAD W
ITH
ALASKA BARRIER
EQUIPMENT PAD W
ITH
ALASKA BARRIER
EQUIPMENT PAD W
ITH
PAD
DUAL DUMPSTER
(4 ROW
S OF 14)
PARKING
COVERED
ADDITIONAL
CONCRETE JERSEY BARRIERS (TYP.)
AND SUNSHADE
STORAGE AREA
EQUIPMENT PAD
EQUIPMENT PAD
BUILDING (OPTION)
FOR HEADQUATERS
ADDITIONAL W
ING
(TYP. OF 4)
SLIDING GATES
CONVERTER
FREQUENCY
CONVERTER
FREQUENCY
CONVERTER
FREQUENCY
GATE
SW
ING
GATE
SW
ING
(OPTION)
HIGH BAY
MAINTENANCE
(OPTION FOR ASPHALT PVMT)
4.00m GRAVEL PATROL ROAD
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXXX
XXXX
X
X
X
X X
X
X
X
X
X
X
X
X
X
MEC
CA
MEC
CA
XX
XX
XX
XX
ACCESS
AND GRAVEL
DBL. SW
ING GATE
TRUCK ENTRANCE
SECONDARY
Y=3246267.89
X=742792.58
Y=3246622.34
X=743215.59
Y=3246676.50
X=743385.04
Y=3246732.71
X=743417.49
Y=3246849.50
X=743484.92
Y=3246672.91
X=743521.06
Y=3246816.24
X=743603.81
Y=3246816.24
X=743603.81
Y=3247143.25
X=743554.79
Y=3246921.29
X=743939.22
Y=3247087.96
X=744034.59
Y=3247309.17
X=743651.45
Y=3247517.51
X=743641.66
Y=3247184.73
X=744218.04
Y=3246480.01
X=743811.17
Y=3246812.79
X=743234.79
Y=3247040.00
X=743733.00
Y=3246911.42
X=743377.51
VEHICLE CRASH BARRIER
BARRIER
CRASH
VEHICLE
+020
+040
+060
+080
0+100
+120
+140
+160
+180
0+200
+220
+240
+260
+280
0+300
+320
+340
+360
+380
0+400
+420
+440
+220
+240
+260
+280
1+300
POE=1+976.198
PI=0+443.559
+320
+340
+360
+380
1+400
+420
+440
+460
+480
1+500
+520
+540
+560
1+600
+580
+620
+640
+660
1+700
+720
+740
+760
+780
1+800
+820
2+600
+620
+640
+660
+680
2+700
+720
+740
0+0002+765+
+760
+120 0
0+100
0+
0+
0+
0+
0+
0+
0+600
0+
+020
+040
+060
+080
+120
+140
+160
+180
+220
+240
+260
+280
+320
+340
+360
+380
+420
+440
+460
+480
+520
+540
+560 +580
+620 +640
+660 +680
0+000.000
POB
.6
P O
E
0+000
0+200
0+500
0+600
1+100
1+200
1+300
1+400
1+
1+800
1+900
1+976
+020
+040
+060
+080
+140 +160
+180
+220 +240
+2
+460
+480
+520
+540
+560
+580
+620
+640
+660 +680
+080
+120
+140
+160
+180
+220
+240
+260
+280
+320
+340
+360 +380
+420
+440
+460
+480
+820
+840
+860
+880
+920
+940
+960
.0
P O
B
+680
SHEET ID
-0
-1
C-102
A J F
J P
R
X
Middle East District of Engineers
US Army Corps
U S A rm y C o rp s o f
E n g in e e rs
M id d le E a s t
D is tr ic t
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
GRAPHIC SCALE
DIM. NOTE & NORTH
KEY PLAN
GENERAL SHEET NOTES
DIMENSIONS SHOWN ARE IN METERS.
UNLESS OTHERWISE NOTED, LINEAR
n e n s a jf
IP
P W
P d
C S
P
N .d g n
-0
-1
A
IR
D
E F
E N
S E I
M P
R O
V E
M E
N T S
U N
S P
E C
IF
IE
D W
O R
L D
W
ID
E
:1
P -4
1:1000
10 10 20 30 40 50 60 70 80 90
FOR CONTINUATION SEE SHEET C-103
7.30
EXISTING ASPHALT ROADCONNECT ENTRANCE ROAD TO EXISTING ROAD EDGE OF PAVEMENT
S
IT
E
A
L S
1.00
MAPPING.
COORDINATES WITH THE COR BASED ON TOPOGRAPHIC
AERIAL IMAGERY. CONTRACTOR MAY HAVE TO CONFIRM
1. COORDINATES SHOWN ON THE PLANS ARE BASED ON
.0
R
C h ie f, A rc h it e c t
B ra n c h
J E
F F
R E
Y P
R A
N E
Y
A J F
N
M E
C C
A
SCALE = 1:1000
ENLARGED SITE PLAN
E
L A
R G
E D S
IT
E P
L A
N
(SEE DETAIL 4/C-514)
AND GRAVEL SHOULDERS
7.3m ASPHALT ENTRANCE ROAD
STOP SIGN
(40 km/hour)
SPEED LIMIT SIGN
/2
/2
C S -7
P N
A M
A D
D E
D T
R A
F F
IC
S
IG
REGULATORY SIGN SIZE
< 40
DESIGN SPEED
Km/hr
REGULATORY SIGN
SIZE (mm)
LETTER HEIGHT ON SUPPLEMENTARY
PLATES (mm)
"Alef"
"X"
< 80 750 140 100
366148
N.G.L
SCALE = NTS
FOR CONCRETE SIDEWALKS
STANDARD JOINT LAYOUT
SCALE = NTS
TYPICAL SIDEWALK DETAILS
BUILDING
SEE NOTE 2 FOR SPACING
CONTRACTION JOINTS (TYP)
JOINTS (TYP)
EXPANSION
CURB
BACK OF
2.
1.
NOTES:
1500 INTERVALS.
CONTRACTION JOINTS SHALL BE SPACED
UNLESS OTHERWISE NOTED.
ALL SIDEWALKS SHALL BE 100 THICK
15000 MAX SPACING BETWEEN EXPANSION JOINTS
SUBGRADE @ 95%
SUBGRADE @ 95%
EXPANSION JOINT
CONTRACTION JOINT
T Y
PX X
X X
WWF
WWF
MATERIAL
EXPANSION JOINT
R
R
NOT TO SCALE
2% 2%
NOT TO SCALE
2% 2%
NOT TO SCALE
2% 2%
MINIMUM 40 SURFACE COURSE
AGGREGATE BASE COURSE
MINIMUM 100 GRADED CRUSHED
MINIMUM 200 CONCRETE PAVEMENT
AGGREGATE BASE COURSE
MINIMUM 150 GRADED CRUSHED
AND FUEL FILLSTAND
EXTERIOR TRAVEL AREA OF STORAGE PAD
CONCRETE PAVEMENT SECTION FOR
5% 5%
1000 1000
SHOULDER
AGGREGATE
MINIMUM 150
SHOULDER
AGGREGATE
MINIMUM 150
5%
SHOULDER
AGGREGATE
MINIMUM 150
5%
SHOULDER
AGGREGATE
MINIMUM 150
ASPHALT PAVEMENT SECTION
MINIMUM 60 ASPHALT TYPE 1 BASE COURSE
NOT TO SCALE
2% 2%
MINIMUM 40 SURFACE COURSE
AGGREGATE BASE COURSE
MINIMUM 100 GRADED CRUSHED
5% 5%
1000 1000
SHOULDER
AGGREGATE
MINIMUM 150
SHOULDER
AGGREGATE
MINIMUM 150
5%
SHOULDER
AGGREGATE
MINIMUM 150
5%
SHOULDER
AGGREGATE
MINIMUM 150
MINIMUM 40 ASPHALT TYPE 3 WEARING COURSE
MINIMUM 100 CRUSHED AGGREGATE BASE COURSE
+2% AND -1% OF OPTIMUM MOISTURE CONTENT)
MODIFIED PROCTOR TEST (ASTMD1557) AND
BELOW EXISTING GRADE, COMPACTED TO 95% OF
SELECT MATERIAL FILL (MINIMUM 150 MM
+2% AND -1% OF OPTIMUM MOISTURE CONTENT)
MODIFIED PROCTOR TEST (ASTMD1557) AND
BELOW EXISTING GRADE, COMPACTED TO 95% OF
SELECT MATERIAL FILL (MINIMUM 150 MM
+2% AND -1% OF OPTIMUM MOISTURE CONTENT)
MODIFIED PROCTOR TEST (ASTMD1557) AND
BELOW EXISTING GRADE, COMPACTED TO 95% OF
SELECT MATERIAL FILL (MINIMUM 150 MM
+2% AND -1% OF OPTIMUM MOISTURE CONTENT)
MODIFIED PROCTOR TEST (ASTMD1557) AND
BELOW EXISTING GRADE, COMPACTED TO 95% OF
SELECT MATERIAL FILL (MINIMUM 150 MM
GRAVEL PATROL ROAD PAVEMENT SECTION
GRAVEL PAVEMENT SECTION
NOT TO SCALE
2% 2%
AGGREGATE BASE COURSE
MINIMUM 100 GRADED CRUSHED
5% 5%
1000 1000
SHOULDER
AGGREGATE
MINIMUM 150
SHOULDER
AGGREGATE
MINIMUM 150
+2% AND -1% OF OPTIMUM MOISTURE CONTENT)
MODIFIED PROCTOR TEST (ASTMD1557) AND
BELOW EXISTING GRADE, COMPACTED TO 95% OF
SELECT MATERIAL FILL (MINIMUM 150 MM
MINIMUM 60 ASPHALT TYPE 1 BASE COURSE
NOT TO SCALE
TRAFFIC SIGN BOARD DETAIL
ASPHALT PATROL ROAD PAVEMENT SECTION (OPTION)
EXISTING
STEEL PIPE
COMPACTED SOIL
SHOULDERROAD
PLAIN CONCRETE
SHEET ID
-0
-1
A J F
A J F
J P
R
X
Middle East District of Engineers
US Army Corps
U S A rm y C o rp s o f
E n g in e e rs
M id d le E a s t
D is tr ic t
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R n e n s a jf
IP
P W
P d
C S
D
T .d g n
-0
-1
A
IR
D
E F
E N
S E I
M P
R O
V E
M E
N
S P
E C
IF
IE
D W
O R
L D
W
ID
E
P -4
C-514
P A
V E
M E
N T D
E T
A
IL
IT
E
A
L S
DIMENSIONS SHOWN ARE IN MILLIMETERS.
UNLESS OTHERWISE NOTED, LINEAR
C h ie f, A rc h it e c t
B ra n c h
J E
F F
R E
Y P
R A
N E
Y
NOTE: SEE SITE PLANS FOR LOCATIONS.
STOP SIGN SIGN
SPEED LIMIT
/2
/2
C S -7
D T
A M
R E
IS
S U
E D E
N T
IR
E S
H E
STATE DEPARTMENT RATING
K12 = 15,000 POUND VEHICLE TRAVELING AT 80 KPH (50 MPH)
HANDLE FOR MANUAL OPERATION
OPERATION:
BARRIER RATING: K12
NOT TO SCALE
GROUNDING DETAIL
C-521
BARBED TAPE MOUNTING DETAIL
NOT TO SCALE
C-522
STEEL TIE WIRE DETAIL
NOT TO SCALE
LOCK PIN, TYP.
OUTRIGGER
ON BOTH SIDES OF
AT EVERY SPIRAL TURN
TO TOP BARBED WIRES
BOTH TAPE COILS TIED
RIVETED FLUSH, TYP.
10 PLAIN PIN
BARBED WIRE
BARBED TAPE
STEEL TIE WIRE
16-GAGE STAINLESS
FENCE POST
#8 AWG SOLID COPPER WIRE
FITTING OF COPPER
OR APPROVED CLAMP-TYPE
MOLDED EXOTHERMIC WELD
FOR CLARITY)
(BARBS OMITTED
CONCERTINA
STEEL BARBED-TAPE
STEEL GROUND ROD
COPPER-CLAD
19 DIAMETER
C-104
CRASH BEAM BARRIERS
NOT TO SCALE
ARM
GRADE LEVEL
OPERATION.
OPTION FOR MANUAL
ELECTRICAL WITH
NOT TO SCALE
BOLLARD DETAIL
600 MIN.
SHEET ID
-0
-1
C-522
A J F
A J F
J P
R
X
DIMENSIONS SHOWN ARE IN MILLIMETERS.
UNLESS OTHERWISE NOTED, LINEAR
Middle East District of Engineers
US Army Corps
U S A rm y C o rp s o f
E n g in e e rs
M id d le E a s t
D is tr ic t
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R n e n s a jf
IP
P W
P d
C S
D
T .d g n
-0
-1
-4
S P
E C
IF
IE
D W
O R
L D
W
ID
E
A
IR
D
E F
E N
S E I
M P
R O
V E
M E
N T S
J E
F F
R E
Y P
R A
N E
Y S
IT
E
A
L S
C h ie f, A rc h it e c t
B ra n c h
C H
A
IN
L
IN
K S
E C
U R
IT
Y F
E N
C E D
E T
A
IL
S
/2
/1
A
M E
N D
M E
N T
C S -7
D T m m
(FABRIC NOT SHOWN IN TAIL)
INSIDE
OUTSIDE
SCALE = NTS
GATE PLAN
SCALE = NTS
GATE ELEVATION - (5) BAYS SHOWN
TO OPEN
F R
A M
E H
E
IG
H T
H
LENGTH (L) SEE TABLE (SHEET C-543)
TOPENING
m m
TAILFABRIC AREA
ALUMINUM UPRIGHT
50mm SQUARE
ARM, TYPICAL
BARBED WIRE
50mm SQUARE
BARBED WIRE
(3) STRANDS OF
ALUMINUM UPRIGHT
50mm SQUARE POST TOP
DIAMETER POST
102mm OUTSIDE
ALUMINUM UPRIGHT
50mm SQUARE
CHAIN LINK FABRIC
(TYPICAL OF 4)
TRUCK ASSEMBLY
CHAIN LINK FABRIC
ASSEMBLY
GUIDE ROLLER
CABLE TRUSS
ALUMINUM UPRIGHT
50mm SQUARE
ALUMINUM TRACK / RAIL
TENSION ROD
ALUMINUM UPRIGHT
50mm SQUARE
ALUMINUM BOTTOM RAIL
50mm X 102mm
3. FOOTING WIDTH TO BE (4)X POST WIDTH. MININUM DEPTH 915mm.
2. FOR SECTIONS AND DETAILS SEE SHEETS C-542 AND C-543.
SEE SPEC SECTION 01 80 00.12 10.
1. GATES MECHANICALLY OPERATED.
NOTES:
SHEET ID
-0
-1
C-541
E M
S
A J F
J P
R
X
Middle East District of Engineers
US Army Corps
U S A rm y C o rp s o f
E n g in e e rs
M id d le E a s t
D is tr ic t
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R n e n s a jf
IP
P W
P d
C S
D
T .d g n
C h ie f, A rc h it e c t
B ra n c h
J E
F F
R E
Y P
R A
N
Y
-4
L
A N E
L E
V A
T
IO
N
C A
N T
IL
E V
E R
E D S
L
ID
IN
G G
A T
E
DIMENSIONS SHOWN ARE IN MILLIMETERS.
UNLESS OTHERWISE NOTED, LINEAR
-0
-1
S
IT
E
A
L S
A
IR
D
E F
E N
S E I
M P
R O
V E
M E
N T S
U N
S P
E C
IF
IE
D W
O R
L D
W
ID
E
C S -7
D T
/2
/2
A M
R E
V
IS
E D N
O T
E
AREA
STORAGE
CU-H
SDP
TRUCK PARK
CU-G
ROOM
SCREEN
TOWER#2
GUARD
CU-E2
GEN
(FACILITY "L")
POWER PLANT
LOCATED ATGEN
G1 G2
TO HOST POWER
FUTURE CONNECTION
3P
600AF
600AT
1200AF
1200AT
1P
60AT
60AF
1P
60AT
60AF
1P
30AT
30AF
3P
100AF
ECS
LPA7
125AF
125AT
3P 1P 1P 3P 1P
3P
400AF
400AT
100AT
100AF
HQ
LPBa
GATHERING
PRAYER/
MDPM
CAR PARK
CU-F
TOILET
MDPC
100AF
COMM
HQ
CP
3P
200AT
225AF
1P
30AT
1P
30AT
1P
30AT
1P
30AT
60AF
3P
225AF
200AT
CRANE
10TON
TOWER#1
GUARD
CU-E1
3P
125AF
100AT
3P
TOWER# 4
GUARD
CU-E4
MAIN DISTRIBUTION PANEL (MDP1) 1200 AMPS, 415/240V, 3PH, 4W , 50 HZ 50KAIC
IN NEMA 4X ENCLOSURE
W/BYPASS/ISOLATION SWITCH
1200A AUTOMATIC TRANSFER SWITCH
ATS1
IN NEMA 4X ENCLOSURE
W/BYPASS/ISOLATION SWITCH
1200A AUTOMATIC TRANSFER SWITCH
ATS2
IN MANUFACTURERS WEATHERPROOF ENCLOSURE
PRIME RATED SYNCHRONOUS GENERATORS
(2) 750 kVA, 415/240V,50 HZ,0.8 PF, CONDUIT ENDS SHALL BE CAPPED.
PULL WIRES FOR FUTURE CONNECTION,
2 - 100MM EMPTY CONDUIT WITH
125AF
60AT
60AF
MDPBa @ HEADQUATERS (HQ)
MDPP @ MAINTENANCE BAY
S P
A R
E
S P
A R
E
S P
A R
E
S P
A R
E
100AT
3P
LIGHTING
SITE
PILAR 1
FEEDER
FP1
60AF
60AT
LIGHTING
SITE
PILAR 2
FEEDER
FP2
60AF
60AT
3P
3P
125AF
125AT
3P
125AF
125AT
MDPD @ GUARDHOUSE
35 37 39 41 38, 40, 42
1P
16AT
16AF
1P
16AT
16AF
1P
16AT
16AF
1P
16AT
16AF
3P
(BASE BID)
3P
30AT
3P
600AF
600AT
3P
3P
400AF
ECS
COVERTER
FREQUENCY
150KW
125AF
100AT
3P
100AF
400AT
FP FP
PRESENCE
POINT OF
CPS7
HQ
LPBb
WING ADDITION
HQ- BID OPTION
MDPBb
100AF
3P
60AT
ROOM 102 - POWER PLANT (FACILITY "M")
1,3,5 2,4,6 7,9,11 8,10,12 13,15,17 14,16,18
STORAGE
FUEL
CU-N
1P
20,22,24 21
PLANT
POWER
MDPP
60AT
60AF
MDPA7 @ ECS
100AT100AT
100AF
1P
16AT
16AF
S P
A R
E
T
Y P
1P
16AT
16AF
S P
A R
E
T
Y P
1P
16AT
16AF
S P
A R
E
T
Y P
3P
30AT
30AF
S P
A R
E
3P
60AT
60AF
29,31,33
COMM
ECS
CP7
400AT
400AF
3P
1P
30AT
TOWER#3
GUARD
CU-E3
30AT
1P
PARK
TRUCK
FUEL
CU-N2
23,25,27
CONDUCTOR IN 100mm2 CONDUIT EACH.
3 SETS OF 4-#300mm2 & 1-#70mm2 GND
RECOMMENDATIONS (TYP)
WIRING PER MANUFACTURER'S
S P
A R
E
B C C D C E C E F
60AT
60AF 60AF
60AF 60AF
60AF
1 & 2
LAUNCHERS
TO
PDU1
CONVERTER/
FREQUENCY
30KW
TO
MDPI1
3 & 4
LAUNCHERS
TO
PDU2
CONVERTER/
FREQUENCY
30KW
TO
MDI2
LAUNCHER
TO
PDU3
CONVERTER/
FREQUENCY
30KW
TO
MDPI3
60AT
3P
200AT
225AF
30AF
SC7
SHEET ID
X
Middle East District of Engineers
US Army Corps
U S A rm y C o rp s o f
E n g in e e rs
M id d le E a s t
D is tr ic t
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
/2
/2 c u s e r s n e n e ia d o c u m e n t s p w w o r k d
S
IT
E
X E
D I0
.d g n n e n e ia
-0
-1
A
IR
D
E F
E N
S E I
M P
R O
V E
M E
N
S P
E C
IF
IE
D W
O R
L D
W
ID
-4
DIMENSIONS SHOWN ARE IN MILLIMETERS.
UNLESS OTHERWISE NOTED, LINEAR
GENERAL SHEET NOTES
SINGLE LINE DIAGRAM
NOT TO SCALE
S
IT
E
A
L S
GENERATORS SEQUENCE OF OPERATION
BY OTHERS.
COVERED UNDER THIS CONTRACT AND WILL BE PROVIDED
CABLES, STEP DOWN TRANSFORMER AND 11KV SWITCHGEAR IS NOT
6. CONNECTION TO LOCAL UTILITY AND ISTALLATION OF POWER
PROVIDED BY OTHERS.
208/120V, 3 PHASE, 400 HZ. FREQUENCY CONVERTER WILL BE
INPUT IS 415/240V, 3 PHASE, 50 HZ WITH AN OUTUT OF
5. 150 KW AND 30 KW FREQUENCY CONVERTERS POWER
SUPPLIED.
WITH THE RATINGS ON THE ACTUAL NAMEPLATE OF THE EQUIPMENT
4. CONTRACTOR SHALL VERIFY AND CONFIRM CIRCUIT RATINGS
REQUIREMENTS.
3. *TVSS MUST BE SIZED AND INSTALLED AS PER MANUFACTURE'S
CONDUIT ROUTING.
3. REFER TO SITE ELECTRICAL XE-101 AND XE-102 FOR
FEEDER AND CONDUIT SIZES NOT INCLUDED IN THIS SHEET.
2. REFER TO SHEET EL-601 FOR MDP1 PANEL SCHEDULE AND
1. REFER TO SHEET SE-001 FOR LEGEND AND ABBREVIATIONS.
D A
V
ID
S
C L
A R
K E P .E
C h ie f, E le c tr ic a l B ra n c h
XE-601
IA
IA M
M
S
IN
G L E L
IN
E D
IA
G R
A M
OPERATION WILL OCCUR.
DESIGN, IF REQUIRED, TO ENSURE ABOVE SEQUENCE OF
IT IS CONTRACTOR'S RESPONSIBILITY TO PERFORM ANY ADDITIONAL
GENERATOR G1 OR G2 AT ANY TIME.
GENERATING UNIT IN THE EVENT OF A FALURE/FAULT IN EITHER
UNIT AND START UP THE OTHER
WITH SENSOR/CONTROLS TO SHUT DOWN THE FAULTY GENERATING
AUTOMATIC TRANSFER SWITCH 2 (ATS2) SHALL ALSO BE EQUIPED
SEQUENCE.
SHALL BE RETEATED AS A NORMAL OPERATIONAL
c. SEQUENCE OF OPERATION STATED IN "a" AND "b" ABOVE
AND G1 SHALL GO TO STAND-BY MODE.
START AND RUN FOR A PERIOD OF 48 CONTINUOUS HOURS
b. AFTER 48 HOURS OF OPERATION, GENERATOR 2 (G2) SHALL
PERIOD OF 48 CONTINUOUS HOURS.
a. GENERATOR 1 (G1) SHALL START FIRST AND RUN FOR A
BELOW.
TRANSFER SCHEME BETWEEN THE TWO GENERATORS AS DESCRIBED
PROVIDED WITH A CONTROL SYSTEM TO SUPPORT THIS TRANSITION
AUTOMATIC TRANSFER SWITCH 2 (ATS2) SHALL BE DESIGNED AND
ION TO THE SITE UTILITY ONCE POWER IS AVAILABLE AT THE SITE.
OPERATION. AUTOMATIC SWITCH 1 (ATS1) IS FOR FUTURE CONNECT-
TWO GENERATORS (G1 AND G2) AFTER A CERTAIN PERIOD OF
DESIGN IS TO MAKE TRANSITION (TO ALTERNATE) BETWEEN THE
GENERATOR SHALL BE OPERATING AT A TIME. THE INTENT OF THE
GENERATOR 1 AND 2 SHALL BE BOTH PRIME RATED. ONLY ONE
CABLE SCHEDULE
F 3-#50mm2, 1-#50mm2 AND 10mm2 GND IN 38mm CONDUIT.
E 3-#35mm2 AND 1-#10mm2 GND IN 38mm CONDUIT.
D 3 SETS OF 3-#120mm2, 1-#120mm2 AND 35mm2 GND IN 38mm CONDUIT.
C 3-#35mm2 , 1-#35mm2, AND 10mm2 GND IN 38mm CONDUIT.
B 3 SETS OF 3-#95mm2, 1-#95mm2 AND 25mm2 GND IN 50mm CONDUIT.
A 3 SETS OF 3-#240mm2, 1-#40mm2 AND 50mm2 GND IN 50mm CONDUIT.
A
M E
N D
M E
N T
-S
IT
E
X E
D I0
/2
/2
TVTVTV
TV
W
TVW
PROPOSED LOCATION
FOR FSAMG PATCH PANEL
(NOT TO SCALE)
PROPOSED LOCATION FOR THE TLPJB
CONNECTION BOX . (NOT TO SCALE)
COMM.
OFFICE
105OFFICE
OFFICE
OFFICE
101D
ECS
PARKING
PARTS
101E
FUTURE RACKS
RED SYSTEM
CUSTOMER
INSTALLED RACKS
BLACK SYSTEM
152mm PIPE SLEEVE
FOR CUSTOMER
INSTALLED CABLE
PLASTIC BUSHING
TO BE PROVIDED
FLUSH WITH OUTSIDE
WALL
T-511
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5 7/
/2
6:
:3
A M
7/
/2
6:
:3
AM
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
- C O
N
TR
AC
T
N U
M
BE
R
Middle East District
C H
D I
D
AV
E S
. C
LA
R
KE
A
-T N
1P
N
T-111
W
IN
C H
E
ST
E R
, V A
D I
TE
LE
C O
M M
U N
IC
A
T I O
N S
G
RO
U
ND
F
LO
O R
P
LA
N
SI
TE
A
P2 -4
EN
G
A G
EM
EN
T C
O
NT
RO
L
ST
A
TI
O
N
1 : 100
TELECOM GROUND FLOOR PLAN - SITE 07
3-CONDUITS
TO MH-11
6-CONDUITS
TO MH-10
4-CONDUITS
TO MH-10
6-CONDUITS
TO MH-11
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A M
E N
D M
EN
T
#3
/2 5/
1:100
10m2m 8m6m4m0m
T-201 1
T-201 4
T-201 3
T-201
CABLE TRAY:
457mm (WIDTH) x 177mm (DEPTH) 5486mm AFF
CABLE TRAY:
610mm (WIDTH) x 152mm (DEPTH) 2743.2mm AFF
PROPOSED LOCATION
FOR FSAMG PATCH PANEL
(NOT TO SCALE)
PROPOSED LOCATION FOR THE TLPJB
CONNECTION BOX . (NOT TO SCALE)
CABLE TRAY:
610MM (WIDTH) x 152mm
(DEPTH)
2743.2 AFF
CABLE TRAY:
610mm (WIDTH) x 152 (DEPTH)
3660 AFF
COMM.
OFFICE
105OFFICE
OFFICE
OFFICE
101D
ECS
PARKING
PARTS
101E
457mm x 178mm
LADDER TYPE
CABLE TRAY,
229mm
BETWEEN RUNGS
CUSTOMER
INSTALLED RACKS
BLACK SYSTEM
LADDER CABLE TRAY
FROM TOWER
610mm X 178mm
CABLE LADDER TO BE
SUPPORTED VIA THE
METHOD DESIGNATED BY
THE TOWER INSTALLERS
152mm PIPE SLEEVE
FOR CUSTOMER
INSTALLED CABLE
PLASTIC BUSHING
TO BE PROVIDED
FLUSH WITH OUTSIDE
WALL
T-211 1
T-211 2
T-211
T-211 4
NOTE 2: INSTALL A GROUND BAR ON BOTH PORTIONS OF THE CABLE
LADDER INSIDE THE SCREEN ROOM. CONNECT THE CABLE LADDER
GROUND BARS TO THE WALL-MOUNTED TGB IN THE SCREEN ROOM.
INSTALL GROUND BAR (TGB) BELOW THE FSAMG PATCH PANEL.
MOUNT TGB 457mm ABOVE FINISHED GRADE. CONNECT TO
BLDG GROUND VIA CABLE SIZED IAW ANSI EIA/TIA 607.
TERMINATOR PANEL
LOCATION CUSTOMER
TO INSTALL TERMINATOR
PANEL
FUTURE RACKS
RED SYSTEM
RAYTHEON INSTALLED CABLE
TO DROP DOWN FROM WALL
MOUNTED VERTICAL CABLE
LADDER TO HORIZONTAL TRAPEZE
MOUNTED CABLE LADDER TO
TERMINATOR PANEL
INSTALL GROUND BAR
(TGB) 457mm AFF FOR
CONNECTION TO CABLE
LADDER SYSTEM.
INSTALL GROUND BAR
(TGB) 457mm AFF FOR
CONNECTION TO CABLE
LADDER SYSTEM.
INSTALL GROUND BAR
(TGB) 457mm AFF FOR
CONNECTION TO CABLE
LADDER SYSTEM.
INSTALL GROUND BAR (TGB) BELOW THE CONNECTION BOX.
MOUNT TGB 457mm ABOVE FINISHED GRADE. CONNECT TO
BLDG GROUND VIA CABLE SIZED IAW ANSI EIA/TIA 607.
SEE NOTE 1
NOTE1: INSTALL GROUND BAR (TGB) 152mm BELOW THE SCREEN ROOM
PENETRATION PLATE. CONNECT TO BUILDING GROUND BAR IN MDPA6
VIA GROUND CABLE SIZED IAW ANSI EIA/TIA 607. INSTALL A 16mm2 COPPER CONDUCTOR FROM THE TGB TOA A LOCATION 152mm BELOW EACH OF
THE FOUR (4) ROOM PENETRATION PLATE[S]. TERMINATE CABLE IN A ONE-
HOLE LUG BOLTED TO THE TOP OF AN INSULATOR.
NOTE 2
NOTE 2
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5 7/
/2
6:
:1
A M
7/
/2
6:
:1
AM
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
- C O
N
TR
AC
T
N U
M
BE
R
Middle East District
C H
D I
D
AV
E S
. C
LA
R
KE
A
-T N
2P
N
T-112
W
IN
C H
E
ST
E R
, V A
D I
TE
LE
C O
M M
U N
IC
A
T I O
N S
C A
BL
E
T R A
Y
PL
A N
SI
TE
A
P2 -4
EN
G
A G
EM
EN
T C
O
NT
RO
L
ST
A
TI
O
N
1 : 100
TELECOM CABLE TRAY PLAN - SITE 07 ALS
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A M
E N
D M
EN
T
#3
/2 5/
1:100
S S S
COMM.
OFFICE
105OFFICE
OFFICE
OFFICE
101D
ECS
PARKING
PARTS
101E
FUTURE RACKS
RED SYSTEM
CUSTOMER
INSTALLED RACKS
BLACK SYSTEM
FC ROOM
ENLISTED TOILET
101B
OFFICER TOILET
101C
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5 7/
/2
6:
:0
A M
7/
/2
6:
:0
AM
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
- C O
N
TR
AC
T
N U
M
BE
R
Middle East District
D I
D I
D
AV
E S
. C
LA
R
KE
A
-T N
3P
N
T-113
W
IN
C H
E
ST
E R
, V A
C H
TE
LE
C O
M S
E C U
R E
VO
IC
E P L
A N
SI
TE
A
P2 -4
EN
G
A G
EM
EN
T C
O
NT
RO
L
ST
A
TI
O
N
1 : 100
TELECOM SECURE NETWORK PLAN - SITE 7
SHEET NOTES:
1) THE MAIN DISTRIBUTION PDS (PROTECTIVE DISTRIBUTION
SYSTEM) LARGE RACEWAY SHALL BE A NOMINAL 86mm X 152mm (3.4" x 6"), WALL-MOUNTED AND PLACED 2850mm ABOVE
FINSIHED FLOOR (AFF). MINIMUM CLEARANCE BETWEEN THE
PDS AND CEILING SHALL BE 50mm (2").
2) LARGE FEEDER PDS SHALL BE INSTALLED IN THE HALLWAY.
3) THE PDS CONNECTING THE LARGE DISTRIBUTION RACEWAY
PDS TO THE USER DROP BOX ENCLOSURE SHALL BE A NOMINAL
50mm X 50mm (2"x2").
4) PDS USER DROP BOXES (UDB) SHALL BE WALL-MOUNTED
1200mm (48") AFF. NOMINAL DIMENSIONS SHALL BE H-190mm X W-152mm X D-102mm (7.5" X 6" X 4").
5) PDS SHALL BE WALL-MOUNTED AND FULLY EXPOSED TO
ALLOW FOR VISUAL INSPECTION IN ACCORDANCE WITH SECURE
SYSTEM REQUIREMENTS AND SPECIFICATIONS.
6) ALL PDS COMPONENTS SHALL BE COMPATIBLE AND
PRODUCED BY THE SAME MANUFACTURER.
7) THE SECURE SYSTEM COMM ROOM 108 DETAILS ARE
LOCATED ON SHEET T-501.
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A M
E N
D M
EN
T
#3
/2 5/
1:100
FIN. FLOOR
T.O. WALL
T.O. SLAB
T.O. WALL
A B C D E
T.O.S. ICC ROOF
T.O. ECS ROOF
B.O. SIDING
6000T.O.STAIRS
610mm WIDE x 100mm
DEEP CABLE LADDER
PATCH
PANEL
610 610
RUNG DROPOUT
FITTINGS AT
THESE LOCATIONS
FOR UPPER CABLE
LADDER
TGB
FIN. FLOOR
A
T.O. ECS ROOF
FIN. FLOOR
FIN. FLOOR
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5 7/
/2
6:
:2
A M
7/
/2
6:
:2
AM
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
- C O
N
TR
AC
T
N U
M
BE
R
Middle East District
C H
D I
D
AV
E S
. C
LA
R
KE
A-
TN
1E L0
T-211
W
IN
C H
E
ST
E R
, V A
D I
TE
LE
C O
M E
L E
VA
TI
O
N D
ET
AI
LS
SI
TE
A
P2 -4
EN
G
A G
EM
EN
T C
O
NT
RO
L
ST
A
TI
O
N
1 : 50
CABLE LADDER TO PATCH PANEL - SITE 07
1 : 50
CABLE LADDER TRANSITION - SITE 7 1 : 50
SCREEN ROOM CABLE LADDER & CABINET VIEW - SITE 7
1 : 50
SCREEN ROOM CABLE LADDER & CABINET VIEW 1 - SITE 7
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A M
E N
D M
EN
T
#3
/2 5/
1:50
5m1m 4m3m2m0m
3 -115mm
CONDUIT
TO MH-11
TMGB
RACK #1
RACK #2
100 PR
PET
COAX SWING-
DOWN RACK
305mm (WIDTH) CABLE LADDER RACK
CABINET #1 CABINET #2
SECURE VOICE SYSTEM PDS
86mm X 152mm (SEE SHEET(s) T-103, T-113)
SECURE VOICE SYSTEM
SWING-OUT RACK
6-115mm
CONDUIT
TO MH-10
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5 7/
/2
6:
:3
A M
7/
/2
6:
:3
AM
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
- C O
N
TR
AC
T
N U
M
BE
R
Middle East District
C H
D I
D
AV
E S
. C
LA
R
KE
A-
TN
1D T0
T-511
W
IN
C H
E
ST
E R
, V A
D I
TE
L E
C O
M R
M
E
N
LA
RG
ED
F L O
O R
PL
A
N
S I
TE
A
P2 -4
EN
G
A G
EM
EN
T C
O
NT
RO
L
ST
A
TI
O
N
1 : 20
ENLARGED COMM RM 108 - SITE 7
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A M
E N
D M
EN
T
#3
/2 5/
1:20
2m0.4m 1.6m1.2m0.8m0m
NOTE 1
NOTE 1
NOTE 3
NOTE 1
NOTE 2
48 STRAND, OSP SINGLE MODE FIBER TO HQs COMM
ROOM FOR VOICE/DATA CONNECTION
NOTE 1: 2 RMU HORIZONTAL CABLE MANAGEMENT BAR
NOTE 2: 4 RMU FIBER OPTIC COMBINATION UNIT WITH
FOUR (4) SINGLE MOCE SC CONNECTOR PANELS
AND EIGHT (8) BLANK PANELS. PROVIDE FORTY-
EIGHT (48) SINGLE MODE PATCH CORDS SC-SC.
NOTE 3: 48 PORT, CATEGORY 6, UTP PATCH PANEL.
PROVIDE FORTY EIGHT CATEGORY 6 GREEN
PATCH CORDS, RJ45-RJ45.
NOTE 4: 4 RMU FIBER OPTIC COMBINATION UNIT WITH
TWO (2) SINGLE MOCE SC CONNECTOR PANELS
AND TEN (10) BLANK PANELS. PROVIDE TWENTY-
FOUR (24) SINGLE MODE PATCH CORDS SC-SC.
NOTE 5: CABINETS AND RACKS SHALL BE PROVISIONED
AS DEPICTED IN DRAWINGS (NOTES 1-4). ALL
OTHER ELECTRONIC EQUIPMENT SHALL BE
CUSTOMER PROVIDED.
NOTE 6: PROVIDE TWO (2) DEDICATED ELECTRICAL POWER
CIRCUITS PER EACH RACK AND CABINET, EACH
CIRCUIT WITH A DEDICATED CIRCUIT BREAKER.
CABINET 1 CABINET 2
(SPARE)
RACK 1
(SPARE)
RACK 2
SECURE VOICE
SYSTEM
NOTE 1
NOTE 1
NOTE 1
NOTE 4
24 STRAND, OSP SINGLE MODE FIBER TO HQs COMM
ROOM FOR SECURE VOICE NETWORK CONNECTION
NOTE 3
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
SHEET OF
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5 7/
/2
6:
:5
A M
7/
/2
6:
:5
AM
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
- C O
N
TR
AC
T
N U
M
BE
R
Middle East District
D I
D I
D
AV
E S
. C
LA
R
KE
A-
TN
2D T0
T-512
W
IN
C H
E
ST
E R
, V A
C H
TE
L E
C O
M M
U N
IC
A
TI
O
N S
C A
B
IN
E T D
ET
AI
LS
SI
TE
A
P2 -4
EN
G
A G
EM
EN
T C
O
NT
RO
L
ST
A
TI
O
N
SHEET NOTES:
COMM RM 108 CABINET & RACK DETAILS - SITE 7
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A M
E N
D M
EN
T
#3
/2 5/
NOT TO SCALE
W
W W
TV
TV
TV
TV
TV
TV
TV
TV
TV
TV
T-401
LECTURE HALL
104 SECURITY
106D
ARMS
103AMMO
106C
ENLISTED
BARRACKS
ENLISTED
BREAK ROOM
FIRST AID
RM.
MECH.
JAN.
KITCHEN
COMM
KITCHEN
OFFICER
BREAK RM
OFFICE
ELEC.
TOILET
114A
CONTROL
CENTER
OFFICE
OFFICE SUITE
OFFICE
ENTRY
CORR.
106A
VEST
106 VESTIBULE
VEST
ENTRY
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5 7/
/2
7:
:5
A M
7/
/2
7:
:5
AM
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
- C O
N
TR
AC
T
N U
M
BE
R
Middle East District
D I
D I
D
AV
E S
. C
LA
R
KE
B
-T N
1P
N
T-111
W
IN
C H
E
ST
E R
, V A
C H
TE
LE
C O
M F
LO
O
R P
LA
N
SI
TE
B
P2 -4
H
EA
DQ
UA
R
TE
RS
B
U I
LD
IN
G
1 : 100
TELECOM FLOOR PLAN - SITE 7
NOTE: COMMUNICATIONS OUTLETS SHALL BE PLACED
450mm AFF AND SHALL BE CONNECTED TO THE CABLE TRAY SYSTEM WITH 25mm CONDUIT.
NOTE: COMMUNICATIONS OUTLETS SHALL BE PLACED
450mm AFF AND SHALL BE CONNECTED TO THE CABLE TRAY SYSTEM WITH 25mm CONDUIT.
NOTES:
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A M
E N
D M
EN
T
#3
/2 5/
1:100
SS
S
S
S
S
S S
S
T-401
OFFICE
OFFICE SUITE
OFFICE
CONTROL
CENTER
OFFICE
TOILET
114A
ELEC.
COMM
OFFICER
BREAK RM
VESTIBULE
ENTRY
ENTRY
VEST
CORR.
106A
ENLISTED
BREAK ROOM
FIRST AID
RM.
MECH.
KITCHEN
JAN.
ENLISTED
BARRACKS
LECTURE HALL
SECURITY
106D
ARMS
AMMO
106C
KITCHEN
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5 7/
/2
7:
:4
A M
7/
/2
7:
:4
AM
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
- C O
N
TR
AC
T
N U
M
BE
R
Middle East District
C H
D I
D
AV
E S
. C
LA
R
KE
B
-T N
2P
N
T-112
W
IN
C H
E
ST
E R
, V A
D I
SE
C
U R
E V O
IC
E
FL
O
O R
P
LA
N
SI
TE
B
P2 -4
H
EA
DQ
UA
R
TE
RS
B
U I
LD
IN
G
1 : 100
SECURE VOICE FLOOR PLAN - SITE 7
1:100
10m2m 8m6m4m0m
1) THE MAIN DISTRIBUTION PDS (PROTECTIVE DISTRIBUTION
SYSTEM) LARGE RACEWAY SHALL BE A NOMINAL 86mm X 152mm (3.4" x 6"), WALL-MOUNTED AND PLACED 2850mm ABOVE
FINSIHED FLOOR (AFF). MINIMUM CLEARANCE BETWEEN THE
PDS AND CEILING SHALL BE 50mm (2").
2) LARGE PDS SHALL BE INSTALLED IN CONTROL CENTER ROOM
121.
3) THE PDS CONNECTING THE LARGE DISTRIBUTION RACEWAY
PDS TO THE USER DROP BOX ENCLOSURE SHALL BE A NOMINAL
50mm X 50mm (2"x2").
4) PDS USER DROP BOXES (UDB) SHALL BE WALL-MOUNTED
1200mm (48") AFF. NOMINAL DIMENSIONS SHALL BE H-190mm X W-152mm X D-102mm (7.5" X 6" X 4").
5) PDS SHALL BE WALL-MOUNTED AND FULLY EXPOSED TO
ALLOW FOR VISUAL INSPECTION IN ACCORDANCE WITH SECURE
SYSTEM REQUIREMENTS AND SPECIFICATIONS.
6) ALL PDS COMPONENTS SHALL BE COMPATIBLE AND
PRODUCED BY THE SAME MANUFACTURER.
7) THE SECURE VOICE SYSTEM CABLE LADDER LOCATED
WITHIN COMM RM. 119 SHALL BE 152mm X 102mm (6" X 4").
SHEET NOTES
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A M
E N
D M
EN
T
#3
/2 5/
W
W
W
W W
TV
S
TV
TV
TV
TV
TV
TV
TV
TV
TV
TV
TV
TV
ELEC.
COMM.
106E
T-402
VESTIBULE
ENTRY
CORR.
OFFICE
OPS
OFFICE
OFFICE
106I
TOILET
106G
MECH.
106F JAN.
106H
ENLISTED
BARRACKS
STORAGE
ELEC.
COMM.
106E
KITCHEN
LECTURE HALL
SECURITY
106D
ARMS
103AMMO
106C
OFFICER
BREAK RM
OFFICE
CONTROL
CENTER
OFFICE
OFFICE SUITE
OFFICE
TOILET
114A
ELEC.
KITCHEN
MECH.
FIRST AID
RM.
JAN.
ENTRY
VEST
CORR.
VEST
COMM
T-411
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5 7/
/2
7:
:2
A M
7/
/2
7:
:2
AM
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
- C O
N
TR
AC
T
N U
M
BE
R
Middle East District
C H
D I
D
AV
E S
. C
LA
R
KE
B
-T N
1P
N
T-121
W
IN
C H
E
ST
E R
, V A
D I
TE
LE
C O
M F
L O O
R P
LA
N
SI
TE
(O
PT
IO
N
B
P2 -4
H
EA
DQ
UA
R
TE
RS
B
U I
LD
IN
G
1 : 100
TELECOM FLOOR PLAN - SITE 7 (OPTION)
NOTES:
NOTE: COMMUNICATIONS OUTLETS SHALL BE PLACED
450mm AFF AND SHALL BE CONNECTED TO THE CABLE TRAY SYSTEM WITH 25mm CONDUIT.
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A M
E N
D M
EN
T
#3
/2 5/
1:100
S
S
S
S
S S
S S
S
SS
S
S
S S
S
ELEC.
COMM.
106E
ENLISTED
BARRACKS
168ENLISTED
BARRACKS
TOILET
106G
OFFICE
OPS
FIRST AID
RM.
MECH.
KITCHEN
ELEC.
COMM
OFFICER
BREAK RM
CONTROL
CENTER
TOILET
114A
OFFICE
OFFICE
OFFICE SUITE
VESTIBULE
101ENTRY
CORR.
CORR.
CORR.
COMM.
106E
ELEC.
STORAGE
170 SECURITY
106D
ARMS
LECTURE HALL
KITCHEN
KITCHEN
OFFICE
OFFICE
OFFICE
106I
MECH.
106F
JAN.
106H
AMMO
106C
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5 7/
/2
7:
:2
A M
7/
/2
7:
:2
AM
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
- C O
N
TR
AC
T
N U
M
BE
R
Middle East District
D I
D I
D
AV
E S
. C
LA
R
KE
B
-T N
2P
N
T-122
W
IN
C H
E
ST
E R
, V A
C H
S E C
U R
E
VO
IC
E
FL
O
O R
P
LA
N
SI
TE
(O
PT
IO
N
B
P2 -4
H
EA
DQ
UA
R
TE
RS
B
U I
LD
IN
G
1 : 100
SECURE VOICE FLOOR PLAN - SITE 7
SHEET NOTES
1) THE MAIN DISTRIBUTION PDS (PROTECTIVE DISTRIBUTION
SYSTEM) LARGE RACEWAY SHALL BE A NOMINAL 86mm X 152mm (3.4" x 6"), WALL-MOUNTED AND PLACED 2850mm ABOVE
FINSIHED FLOOR (AFF). MINIMUM CLEARANCE BETWEEN THE
PDS AND CEILING SHALL BE 50mm (2").
2) LARGE PDS SHALL BE INSTALLED IN OPS ROOM 172 AND
CONTROL CENTER ROOM 121.
3) THE PDS CONNECTING THE LARGE DISTRIBUTION RACEWAY
PDS TO THE USER DROP BOX ENCLOSURE SHALL BE A NOMINAL
50mm X 50mm (2"x2").
4) PDS USER DROP BOXES (UDB) SHALL BE WALL-MOUNTED
1200mm (48") AFF. NOMINAL DIMENSIONS SHALL BE H-190mm X W-152mm X D-102mm (7.5" X 6" X 4").
5) PDS SHALL BE WALL-MOUNTED AND FULLY EXPOSED TO
ALLOW FOR VISUAL INSPECTION IN ACCORDANCE WITH SECURE
SYSTEM REQUIREMENTS AND SPECIFICATIONS.
6) ALL PDS COMPONENTS SHALL BE COMPATIBLE AND
PRODUCED BY THE SAME MANUFACTURER.
7) THE SECURE VOICE CABLE LADDER LOCATED WITHIN COMM
RM. 119 SHALL BE 152mm X 102mm (6" X 4").
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A M
E N
D M
EN
T
#3
/2 5/
1:100
SECURE VOICE
EQUIPMENT
RACK
VOICE/DATA
EQUIPMENT
RACK
CUSTOMER
USE
EQUIPMENT
RACK #2
CUSTOMER
USE
EQUIPMENT
RACK #1
OSP / FIBER
EQUIPMENT
RACK
48ST SM
FEED
2 - 100 PR PETs
DISTRIBUTION
(STACKED)
P E T
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5 7/
/2
8:
:4
A M
7/
/2
8:
:4
AM
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
- C O
N
TR
AC
T
N U
M
BE
R
Middle East District
D I
D I
D
AV
E S
. C
LA
R
KE
B-
TN
1L S
T-411
W
IN
C H
E
ST
E R
, V A
C H
EN
LA
R G
ED
T
EL
EC
O M
R M
SI
TE
B
P2 -4
H
EA
DQ
UA
R
TE
RS
B
U I
LD
IN
G
1 : 20
COMMUNICATIONS ROOM LAYOUT AND RACK PLAN - COMM RM 119 - SITE 7
1 : 20
CABLE LADDER PLAN…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .