SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
B
C
D
2 3 4 5 8/
4/
:3 0:
A
M
8/ 4/
:3
0:
AM
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
Enter District
EM
S
G W
D
R O
B
ER
T L.
F O
X , P
E
-G
I0
G N
G-012
JA
R
IN
D
EX
O
F
DR
A W
IN
G
S
VO
LU
M
E
SH
EE
T
P2 -4
G
EN
ER
A
L
INDEX OF DRAWINGS
443309-SITE DESIGN 06-ALJ
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
CIVIL
C-000 443309--CS000-6LS SITE 6 GRAPHIC REPRESENTATIONS
C-001 443309--CS001-6LS OVERALL PROJECTS LOCATION MAP
C-002 443309--CS002-6PN LAYDOWN AND HAUL ROUTE PLAN
C-100 443309--CS100-6PN03 3 AM#3 DEMOLITION PLAN
C-101 443309--CS101-6PN SITE 06 OVERALL PLAN
C-101A 443309--CS101A-6PN ALJ SITE 06 OVERALL SITE PLAN OPTIONAL BID ITEMS
C-102 443309--CS102-6PN03 3 AM#3 SITE PLAN SITE 6
C-103 443309--CS103-6PN SITE PLAN SITE 6
C-104 443309--CS104-6PN SITE PLAN SITE 6
C-105 443309--CS105-6PN SITE PLAN SITE 6
C-401 443309--CU401-6PN UTILITY PLAN SITE 6
C-402 443309--CU402-6PN UTILITY PLAN SITE 6
C-501 443309--CU501-6DT SANITARY SEWER HOLDINGS TANK DETAILS
C-502 443309--CU502-6DT LEACH FIELD PLAN
C-503 443309--CU503-6DT SEPTIC TANK AND LEACH FIELD DETAILS
C-504 443309--CU504-6DT LEACH FIELD DETAILS
C-505 443309--CU505-6DT EQUIPMENT PAD DETAILS
C-506 443309--CU506-6DT STORAGE FACILITY DETAILS
C-507 443309--CU507-6DT UTILITY DETAILS SITE 6
C-508 443309--CI508-6DT MISCELLANEOUS DETAILS
C-509 443309--CI509-6DT03 3 AM#3 PAVEMENT DETAILS
C-510 443309--CS510-6DT RADAR EXCLUSION ZONE DETAILS
C-511 443309--CS511-6DT CHAIN LINK SECURITY FENCE DETAILS
C-512 443309--CS512-6DT03 3 AM#3 FENCE DETAILS AND FORCE PROTECTION
C-513 443309--CS513-6DT FENCE DETAILS
C-514 443309--CS514-6DT DUMPSTER PAD AND DETAILS
C-541 443309--CS541-6DT03 3 AM#3 CANTILEVERED SLIDING GATE PLAN & ELEVATION
C-542 443309--CS542-6DT CANTILEVERED SLIDING GATE SECTIONS
C-543 443309--CS543-6DT CANTILEVERED SLIDING GATE DETAILS
SITE ELECTRICAL
XE-101 443309-SITE06--XE101PN SITE ELECTRICAL POWER
XE-102 443309-SITE06--XE102PN SITE ELECTRICAL POWER
XE-103 443309-SITE06--XE103PN SITE ELECTRICAL - LIGHTING PLAN LAYOUT
XE-104 443309-SITE06--XE104PN SITE ELECTRICAL - LIGHTING
XE-501 443309-SITE06--XE501DT ELECTRICAL DUCKBANK DETAIL
XE-502 443309-SITE06--XE502DT ELECTRICAL PULLBOX DETAIL
XE-601 443309-SITE06--XE601DI03 3 AM#3 SINGLE LINE DIAGRAM
SITE TELECOMMUNICATIONS
XT-101 443309-SITE06--XT101PN04 4 AM#4 TELECOMMUNICATIONS
XT-102 443309-SITE06--XT102PN04 4 AM#4 SITE TELECOMMUNICATIONS
XT-103 443309-SITE06--XT103PN04 4 AM#4 SITE TELECOMMUNICATIONS
XT-501 443309-SITE06--XT501DT MANHOLE WALL DETAIL 1
XT-502 443309-SITE06--XT502DT MANHOLE WALL DETAIL 2
XT-503 443309-SITE06--XT503DT MANHOLE WALL DETAIL 3
XT-504 443309-SITE06--XT504DT04 4 AM#4 DUCT BANK DETAIL 1
XT-505 443309-SITE06--XT505DT DUCT BANK DETAIL 2
XT-506 443309-SITE06--XT506DT DUCT BANK DETAIL 3
XT-507 443309-SITE06--XT507DT04 4 AM#4 DUCT BANK DETAIL 4
XT-508 443309-SITE06--XT508DT CABLE LADDER DETAIL
XT-509 443309-SITE06--XT509DT MANHOLE HARDWARE DETAILS
XT-510 443309-SITE06--XT510DT HANDHOLE AND COVER DETAILS
XT-511 443309-SITE06--XT511DT MANHOLE DETAILS
XT-512 443309-SITE06--XT512DT MANHOLE TO DUCT BANK CONNECTION DETAILS
XT-513 443309-SITE06--XT513DT CABLE RACKING DETAILS
XT-514 443309-SITE06--XT514DT CABLE RACKING DETAILS 2
XT-515 443309-SITE06--XT515DT CABLE RACKING DIAGRAMS 3
XT-516 443309-SITE06--XT516DT CABLE RACKING DIAGRAMS 4
XT-517 443309-SITE06--XT517DT CABLE RACKING DIAGRAMS 5
XT-518 443309-SITE06--XT518DT CABLE RACKING DIAGRAMS 6
XT-519 443309-SITE06--XT519DT CABLE RACKING DIAGRAMS 7
XT-520 443309-SITE06--XT520DT CABLE RACKING DETAILS 8
XT-521 443309-SITE06--XT521DT03 3 AM#3 LAUNCHER HANDHOLE AND TRENCH DETAIL
XT-522 443309-SITE06--XT601DT LAUNCHER HANDHOLE SITE DETAILS
XT-601 443309-SITE06--XT601DI04 4 AM#4 SITE COMMUNICATIONS ONE LINE DIAGRAMS
GENERAL VOLUME 2
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
GENERAL
G-001 450031-GI001GN COVER SHEET VOLUME 2 OF 4
G-004 450031-GI004GN INDEX OF VOLUMES
G-012 443309-GI012GN04 4 AM#4 INDEX OF DRAWINGS VOLUME 2 SHEET 1
G-013 443309-GI013GN04 4 AM#4 INDEX OF DRAWINGS VOLUME 2 SHEET 2
G-021 443309-GI021GN STANDARD LEGENDS AND SYMBOLOGY
G-031 443309-GI031GN STANDARD ABBREVIATIONS
443309A - ENGAGEMENT CONTROL STATION - SITE 06
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309A-SB101PN COMPOSITE FOUNDATION AND SLAB PLAN
S-102 443309A-SB102PN PARTIAL FOUNDATION PLAN - WEST
S-103 443309A-SB103PN PARTIAL FOUNDATION PLAN - CENTER
S-104 443309A-SB104PN PARTIAL FOUNDATION PLAN - EAST
S-105 443309A-SF105PN COMPOSITE ROOF FRAMING PLAN
S-106 443309A-SF106PN PARITIAL ROOF FRAMING PLAN - WEST
S-107 443309A-SF107PN PARTIAL ROOF FRAMING PLAN - CENTER
S-108 443309A-SF108PN ROOF FRAMING PLANS
S-109 443309A-SF109PN PARTIAL ROOF FRAMING PLAN - EAST
S-401 443309A-SF401PN04 4 AM#4 ENLARGED STRUCTURAL PLANS
S-501 443309A-SB501DT STRUCTURAL DETAILS
S-502 443309A-SB502DT STRUCTURAL DETAILS
S-503 443309A-SB503DT STRUCTURAL DETAILS
S-601 443309A-SF601SC SCHEDULES
ARCHITECTURAL
A-001 443309A-AE001PN LIFE SAFETY & AIR BARRIER PLANS
A-101 443309A-AE101PN FLOOR PLAN
A-102 443309A-AE102PN ROOF PLAN
A-201 443309A-AE201EL NORTH SOUTH ELEVATIONS
A-202 443309A-AE202EL WEST EAST ELEVATIONS
A-203 443309A-AE203EL ELEVATIONS - AREA "B"
A-301 443309A-AE301SE SECTIONS
A-302 443309A-AE302SE SECTIONS
A-303 443309A-AE302SE RAMP SECTION
A-304 443309A-AE303SE WALL SECTIONS
A-305 443309A-AE304SE SECTIONS - AREA "B"
A-401 443309A-AE401LS ENLARGED FLOOR PLAN - AREA "A"
A-402 443309A-AE402LS ENLARGED FLOOR PLAN - AREA "B"
A-403 443309A-AE403LS REFLECTED CEILING PLAN - AREA "A"
A-404 443309A-AE404LS REFLECTED CEILING PLAN - AREA "B"
A-405 443309A-AE405LS ENLARGED TOILET PLAN
A-406 443309A-AE406EL SCREEN ROOM
A-501 443309A-AE501DT DETAILS
A-601 443309A-AE601SC DOOR AND FINISH SCHEDULES
PLUMBING
P-101 443309A-PL101PN GROUND FLOOR PLUMBING PLAN - STIE 06
P-102 443309A-PL102PN ROOF PLUMBING PLAN - SITE 06
P-401 443309A-PL401LS ENLARGED PLUMBING PLAN - SITE 06
P-901 443309A-PL901DI RISER DIAGRAMS-SITE 06
MECHANICAL
M-101 443309A-MH101PN GROUND FLOOR HVAC PLAN - SITE 06
M-401 443309A-MH401LS ENLARGED HVAC FLOOR PLAN - SITE 06
M-402 443309A-MH402LS ENLARGED TOILET ROOM PLAN - SITE 06
M-501 443309A-MH501DT FUEL TANK LAYOUT - SITE 06
M-601 443309A-MH601SC MECHANICAL SCHEDULES - SITE 06
ELECTRICAL
E-101 443309A-EP101PN POWER PLAN - AREA "A" - SITE 6 ALJ
E-102 443309A-EL102PN LIGHTING PLAN - AREA "A" - SITE 6 ALJ
E-103 443309A-EP103PN POWER PLAN - AREA " B" - SITE 6 ALJ
E-104 443309A-EL104PN LIGHTING PLAN - AREA " B"- SITE 06 ALJ
E-105 443309A-EP105PN LIGHTING AND POWER PLAN - RADAR RAMP - SITE 6
E-106 443309A-EP106PN04 4 AM#4 GROUNDING AND LIGHTNING PROTECTION PLAN
E-107 443309A-EP107PN04 4 AM#4 GROUNDING AND LIGHTNING PROTECTION PLAN "
AREA B"
E-601 443309A-EP601SC PANEL SCHEDULES - SITE 6
E-602 443309A-EP602SC PANEL SCHEDULE - SITE 6
TELECOMMUNICATIONS
T-101 443309A-TN101PN03 3 AM#3 TELECOMMUNICATIONS GROUND FLOOR PLAN - SITE 6
T-102 443309A-TN102PN04 4 AM#4 TELECOMMUNICATIONS CABLE TRAY PLAN - SITE 6
T-103 443309A-TN103PN03 3 AM#3 TELECOM SECURE VOICE PLAN - SITE 6
T-201 443309A-TN201EL03 3 AM#3 TELECOM ELEVATION DETAILS - SITE 6
T-501 443309A-TN501DT03 3 AM#3 TELECOM RM 108 ENLARGED FLOOR PLAN - SITE 6
T-502 443309A-TN502DT03 3 AM#3 TELECOM RM 108 CABINET & RACK DETAILS - SITE 6
443309B - HEADQUARTERS BUILDING - SITE 06
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309B-SB101PN FOUNDATION AND SLAB PLAN SITE 06-ALJ
S-102 443309B-SF102PN ROOF FRAMING PLAN SITE 06-ALJ
S-601 443309B-SF601SC SCHEDULES SITE 06-ALJ
ARCHITECTURAL
A-001 443309B-AE001PN LIFE SAFETY PLAN - SITE 6 - ALJ
A-002 443309B-AE002PN AIR BARRIER PLAN - SITE 6 - ALJ
A-101 443309B-AE101PN FLOOR PLAN - SITE 6 - ALJ
A-102 443309B-AE102PN CEILING PLAN - SITE 6 - ALJ
A-103 443309B-AE103PN ROOF PLAN - SITE 6 - ALJ
A-201 443309B-AE201EL ELEVATIONS - SITE 06 - ALJ
A-301 443309B-AE301SE SECTIONS- SITE 06- ALJ
A-401 443309B-AE401LS ENLARGED FLOOR PLAN- SITE 06-ALJ
A-601 443309B-AE601SC DOOR & WINDOW SCHEDULES - SITE 6 - ALJ
A-602 443309B-AE602SC FINISH SCHEDULE - SITE 6 - ALJ
PLUMBING
P-101 443309B-MP101PN SITE 6 DOMESTIC WATER FLOOR PLAN
P-102 443309B-MP102PN SITE 6 SANITARY FLOOR PLAN
P-103 443309B-MP103PN SITE 6 PLUMBING ROOF PLAN
P-401 443309B-MP401LS SITE 6 ENLARGED PLUMBING PLANS
P-402 443309B-MP402LS SITE 6 ENLARGED PLUMBING PLANS
P-403 443309B-MP403LS SITE 6 ENLARGED PLUMBING PLANS
P-901 443309B-MP901DI SITE 6 DOMESTIC WATER RISER DIAGRAM
P-902 443309B-MP902DI SITE 6 SANITARY RISER DIAGRAM
MECHANICAL
M-101 443309B-MH103PN SITE 6 HVAC FLOOR PLAN
M-102 443309B-MH104PN SITE 6 HVAC ROOF PLAN
M-601 443309B-MH602SC SITE 6 HVAC SCHEDULES
ELECTRICAL
E-101 443309B-EP101PN POWER FLOOR PLAN - SITE 6 - ALJ
E-102 443309B-EL102PN LIGHTING FLOOR PLAN - SITE 6 -ALJ
E-103 443309B-EP103PN ROOF POWER PLAN - SITE 6 - ALJ
E-104 443309B-EP104PN GROUNDING PLAN - SITE 6 ALJ
E-601 443309B-EP601SC PANEL SCHEDULES - SITE 6 - ALJ
E-602 443309B-EP602SC PANEL SCHEDULES - SITE 6 - ALJ
TELECOMMUNICATIONS
T-101 443309B-TN101PN04 4 AM#4 TELECOM FLOOR PLAN - SITE 6
T-102 443309B-TN102PN03 3 AM#3 SECURE VOICE FLOOR PLAN - SITE 6
T-401 443309B-TN401LS04 4 AM#4 ENLARGED TELECOM RM 119 - SITE 6
T-402 443309B-TN402LS03 3 AM#3 ENLARGED TELECOM RM 106E - SITE 6
T-501 443309B-TN501DT03 3 AM#3 COMM RACK DETAIL SITE 6
443309C - TOILET BUILDING
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309C-SB101PN FOUNDATION AND SLAB PLAN
S-102 443309C-SF102PN ROOF FRAMING PLAN
S-601 443309C-SF601SC SCHEDULES
ARCHITECTURAL
A-001 443309C-AE001PN LIFE SAFETY PLAN
A-002 443309C-AE002PN AIR BARRIER PLAN
A-101 443309C-AE101PN FLOOR AND ROOF PLAN
A-102 443309C-AE102PN REFLECTED CEILING PLAN
A-201 443309C-AE201EL ELEVATIONS
A-301 443309C-AE301SE SECTIONS
A-302 443309C-AE302SE WALL SECTIONS
A-401 443309C-AE401EL INTERIOR ELEVATIONS
A-601 443309C-AE601SC DOOR AND FINISH SCHEDULES
PLUMBING
P-101 443309C-PL101PN GROUND FLOOR PLUMBING PLAN - SANITARY
P-102 443309C-PL102PN GROUND FLOOR PLUMBING PLAN - DOMESTIC WATER
P-103 443309C-PL103PN PLUMBING ROOF PLAN
P-901 443309C-PL901IS PLUMBING RISER DIAGRAM - SANITARY
P-902 443309C-PL902IS PLUMBING RISER - DOMESTIC WATER
MECHANICAL
M-101 443309C-MH101PN GROUND FLOOR HVAC PLAN
ELECTRICAL
E-101 443309C-EP101PN POWER, LIGHTING AND GROUNDING PLAN
E-601 443309C-EP601SC PANEL SCHEDULE
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A M
E N
D M
EN
T
#3
/2 5/
A
M E
N D
M
EN
T #4
/0
2/
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
B
C
D
2 3 4 5 8/
4/
:2 9:
A
M
8/ 4/
:2
9:
AM
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
Enter District
EM
S
G W
D
R O
B
ER
T L.
F O
X , P
E
-G
I0
G N
G-013
JA
R
IN
D
EX
O
F
DR
A W
IN
G
S
VO
LU
M
E
SH
EE
T
P2 -4
G
EN
ER
A
L
INDEX OF DRAWINGS
443309E - GUARD TOWER
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309E-SB101PN FOUNDATION AND SLAB PLAN
S-401 443309$-SS507DT MAT FOUNDATION DETAILS
ARCHITECTURAL
A-001 443309E-AE001PN LIFE SAFETY PLAN
A-101 443309E-AE101PN FLOOR AND ROOF PLAN
A-102 443309E-AE102PN REFLECTED CEILING PLAN
A-201 443309E-AE201EL ELEVATIONS
A-301 443309E-AE301SE BUILDING SECTIONS
A-302 443309E-AE302SE STAIR SECTION & DETAILS
A-601 443309E-AE601SC DOOR AND FINISH SCHEDULES
MECHANICAL
M-101 443309E-MH101PN HVAC FLOOR PLAN
ELECTRICAL
E-101 443309E-EP101PN03 3 AM#3 POWER, LIGHTING AND GROUNDING PLAN
TELECOMMUNICATIONS
T-101 443309E-TN101PN03 3 AM#3 TELECOM FLOOR PLAN
T-201 443309E-TN201EL03 3 AM#3 TELECOM EAST ELEVATION
T-202 443309E-TN202EL03 3 AM#3 TELECOM NORTH ELEVATION
443309F - CAR PARKING SHELTER
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309F-SB101PN FOUNDATION AND SLAB PLAN
ARCHITECTURAL
A-101 443309F-AE101PN PLANS
A-201 443309F-AE201EL ELEVATIONS
A-301 443309F-AE301SE SECTIONS
ELECTRICAL
E-101 443309F-EP101PN POWER, LIGHTING AND GROUNDING
443309G - TRUCK PARKING SHELTER
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309G-SB101PN FOUNDATION AND SLAB PLAN
ARCHITECTURAL
A-101 443309G-AE101PN FLOOR PLAN
A-102 443309G-AE102PN ROOF PLAN
A-103 443309G-AE103PN REFLECTED CEILING PLAN
A-201 443309G-AE201EL ELEVATIONS
A-202 443309G-AE202EL ELEVATIONS
A-301 443309G-AE301SE BUILDING SECTIONS
ELECTRICAL
E-101 443309G-EP101PN POWER, LIGHTING AND GROUNDING PLAN
443309H - STORAGE FACILITY
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309H-SB101PN FOUNDATION AND SLAB PLAN
ARCHITECTURAL
A-101 443309H-AE101PN FLOOR PLAN
A-102 443309H-AE102PN ROOF PLAN
A-103 443309H-AE103PN REFLECTED CEILING PLAN
A-201 443309H-AE201EL ELEVATIONS
A-202 443309H-AE202EL ELEVATIONS
A-301 443309H-AE301SE BUILDING SECTIONS
ELECTRICAL
E-101 443309H-EP101PN04 4 AM#4 LIGHTING, POWER, GROUNDING AND LIGHTNING
PROTECTION PLANS
443309I - FREQUENCY CONVERTER - PDU SHELTER
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309I-SB101PN FOUNDATION AND SLAB PLAN
S-102 443309I-SF102PN ROOF FRAMING PLAN
S-601 443309I-SB601SC SCHEDULES
ARCHITECTURAL
A-001 443309I-AE001PN LIFE SAFETY PLAN
A-002 443309-AE002PN AIR BARRIER PLAN
A-101 443309I-AE101PN FLOOR PLAN
A-201 443309I-AE201EL ELEVATIONS
A-301 443309I-AE301SE SECTIONS
A-601 443309I-AE601SC DOOR AND FINISH SCHEDULES
MECHANICAL
M-101 443309I-MH101PN HVAC FLOOR PLAN
ELECTRICAL
E-101 443309I-EP101PN04 4 AM#4 POWER, LIGHTING AND GROUNDING PLAN
E-601 443309I-EP601SC PANEL SCHEDULES
E-602 443309I-EP602SC PANEL SCHEDULES
443309L - POWER PLANT FACILITY - SITE 06
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309L-SB101PN FOUNDATION & ROOF FRAMING PLAN
S-601 443309L-SF601SC SCHEDULES
ARCHITECTURAL
A-001 443309L-AE001PN LIFE SAFETY PLAN
A-002 443309L-A002PN AIR BARRIER PLAN
A-101 443309L-AE101PN FLOOR PLAN
A-102 443309L-AE102PN REFLECTED CEILING PLAN
A-201 443309L-AE201EL ELEVATIONS
A-301 443309L-AE301SE BUILDING SECTIONS
A-601 443309L-AE601SC DOOR & FINISH SCHEDULES
MECHANICAL
M-101 443309L-M101PN GROUND FLOOR HVAC PLAN
ELECTRICAL
E-101 443309L-EP101PN GROUNDING, POWER AND LIGHTING PLAN
E-601 443309L-EP601SC PANEL SCHEDULES - SITE 6
E-602 443309L-EP602SC PANEL SCHEDULES- SITE 6
TELECOMMUNICATIONS
T-101 443309L-TN101PN03 3 AM#3 COMMUNICATIONS FLOOR PLAN
T-501 443309L-TN502DT03 3 AM#3 COMM ENTRANCE & CABINET DETAIL
443309M - PRAYER/GATHERING BUILDING
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
MECHANICAL
M-101 443309M-MH101PN GROUND FLOOR HVAC PLAN
M-102 443309M-MH102PN ROOF HVAC PLAN
ELECTRICAL
E-101 443309M-EP101PN POWER PLAN
E-601 443309M-EP601SC PANEL SCHEDULE
TELECOMMUNICATIONS
T-101 443309M-TN101PN03 3 AM#3 COMMUNICATIONS FLOOR PLAN
T-501 443309M-TN501PN 6 PAIR PROTECTIVE ENTRANCE TERMINAL (PET)
443309M - PRAYER/GATHERING BUILDING
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309M-SB101PN FOUNDATION AND SLAB PLAN
S-102 443309M-SF102PN ROOF FRAMING PLAN
S-601 443309M-SF601SC SCHEDULES
ARCHITECTURAL
A-001 443309M-AE001PN LIFE SAFETY PLAN
A-002 443309M-AE002PN AIR BARRIER PLAN
A-101 443309M-AE101PN GROUND FLOOR PLAN
A-102 443309M-AE102PN ROOF PLAN
A-103 443309M-AE103PN REFLECTED CEILING PLAN
A-201 443309M-AE201EL ELEVATIONS
A-301 443309M-AE301SE SECTIONS
A-302 443309M-AE302SE WALL SECTIONS
A-501 443309M-AE501DT DETAILS
A-502 443309M-AE502DT DETAILS
A-601 443309M-AE601SC DOOR, WINDOW AND FINISH SCHEDULES
443309N - FUEL DISPENSING SUNSHADE
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309N-SB101PN FOUNDATION AND SLAB PLAN
ARCHITECTURAL
A-101 443309N-AE101PN PLANS
A-201 443309N-AE201EL ELEVATIONS
A-301 443309N-AE301SE SECTIONS
MECHICANICAL
M-101 443309N-MH101PN MECHANICAL PLAN
M-102 443309N-MH102PN FUEL TANK LAYOUT
M-301 443309N-M301SE MECHANICAL SECTION
M-501 443309N-MH501DT FUEL TANK LAYOUT
ELECTRICAL
E-101 443309N-EP101PN LIGHTING, POWER PLAN AND GROUNDING
443309D - GUARD HOUSE
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309D-SB101PN FOUNDATION AND SLAB PLAN
S-102 443309D-SF102PN03 3 AM#3 ROOF FRAMING PLAN
S-401 443309D-SF401DT CONCRETE DETAILS
S-601 443309D-SF601SC03 3 AM#3 SCHEDULES
ARCHITECTURAL
A-001 443309D-AE001PN LIFE SAFETY PLAN
A-002 443309D-AE002PN AIR BARRIER PLAN
A-101 443309D-AE101PN FLOOR PLAN
A-201 443309D-AE201EL ELEVATIONS
A-301 443309D-AE301SE SECTIONS
A-302 443309D-AE302SE WALL SECTIONS
A-401 443309D-AE401LS TOILET PLAN
A-601 443309D-AE601SC DOOR & FINISH SCHEDULES
PLUMBING
P-101 443309D-PL101PN PLUMBING WASTE PLANS
P-102 443309D-PL102PN PLUMBING WATER PLANS
P-301 443309D-PL301SE PLUMBING SECTIONS
P-901 443309D-PL901IS PLUMBING RISER DIAGRAMS
MECHANICAL
M-101 443309D-MH101PN GROUND FLOOR HVAC PLAN
ELECTRICAL
E-101 443309D-EP101PN POWER, LIGTHING AND GROUNDING PLAN
TELECOMMUNICATIONS
T-101 443309D-TN101PN03 3 AM#3 COMMUNICATIONS FLOOR PLAN
T-501 443309D-TN501DT03 3 AM#3 COMM ENTRANCE DETAIL
443309N2 - FUEL TRUCK PARKING SUNSHADE
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309N2-SB101PN FOUNDATION AND SLAB PLAN
ARCHITECTURAL
A-101 443309N2-AE101PN PLANS
A-201 443309N2-AE201EL ELEVATIONS
A-301 443309N2-AE301SE SECTIONS
ELECTRICAL
E-101 443309N2-EP101PN LIGHTING, POWER PLAN AND GROUNDING
443309O - EQUIPMENT PADS
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
ELECTRICAL
E-101 443309O-EP101PN POWER AND GROUNDING PLAN
443309P - MAINTENANCE HIGH-BAY
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309P-SB101PN FOUNDATION AND SLAB PLAN
S-102 443309P-SF102PN BRIDGE CRANE SUPPORT SYSTEM PLAN
S-401 443309P-SB401DT MASONRY AND MBS FOUNDATION DETAILS
S-601 443309P-SB601SC SCHEDULES
ARCHITECTURAL
A-001 443309P-AE001PN LIFE SAFETY PLAN
A-002 443309P-AE002PN AIR BARRIER PLAN
A-101 443309P-AE101PN FLOOR PLAN
A-102 443309P-AE102PN ROOF PLAN
A-103 443309P-AE103PN REFLECTED CEILING PLAN
A-201 443309P-AE201EL ELEVATIONS
A-301 443309P-AE301SE BUILDING SECTIONS
A-302 443309P-AE301SE WALL SECTIONS
A-601 443309P-AE601SC DOOR AND FINISH SCHEDULES
PLUMBING
P-101 443309P-PL101PN GROUND FLOOR PLUMBING PLAN
MECHANICAL
M-101 443309P-MH101PN GROUND FLOOR HVAC PLAN
ELECTRICAL
E-101 443309P-EP101PN GROUNDING AND POWER PLAN
E-102 443309P-EL102PN LIGHTING PLAN
E-601 443309P-EP601SC PANEL SCHEDULE
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A M
E N
D M
EN
T
#3
/2 5/
A
M E
N D
M
EN
T #4
/0
2/
D A
V E C
L A
R K
E
F G
C H
C H
X fi
Middle East District of Engineers
US Army Corps
U S A rm y C o rp s o f
E n g in e e rs
M id d le E a s t
D is tr ic t
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
/2 /2 c u s e r s n e n e d b i\ d o c u m e n t s p w w o r k d
S
IT
E
X T P
N .d g n n e n e d b i
-0
-1
A
IR
D
E F
E N
S E I
M P
R O
V E
M E
N T S
U N
S P
E C
IF
IE
D W
O R
L D
W
ID
E
C h ie f, E le c tr ic a l B ra n c h
E
L E
C O
M M
U N
IC
A T
IO
N
XT-101
P -4
DIMENSIONS SHOWN ARE IN MILLIMETERS.
UNLESS OTHERWISE NOTED, LINEAR
KEY PLAN
GENERAL SHEET NOTES
NN
CONTINUED ON SHEET XT102
S
IT
E
A
L J
12 12
9 9
HH12A
HH13
DWG. XT-505
REFER TO TYPE 3
DWG. XT-507
REFER TO TYPE 9
DWG. XT-507
REFER TO TYPE 12
DWG. XT-507
REFER TO TYPE 13
MH/HH. SEE MH/HH BUTTERFLIES
STUBBED AND CAPPED 3M FROM
CONDUITS FOR FUTURE VOICE TO BE
PAD SLAB TO 3M FROM BARRIER
STUB TWO CONDUITS FROM LAUNCH
AIRCRAFT RATED.
IN LAUNCHER PAD TO BE
BY 152mm. HAND HOLE COVER
FROM ELECTRICAL HAND HOLE
COVER. TRENCH TO BE SEPERATED
492mm HIGH WITH H-20 RATED STEEL
LAUNCHER PAD TO BE 520mm WIDE, HAND HOLE TO CENTER OF
CABLE TRENCH FROM LAUNCHER
EDGE OF ROAD.
ROAD AND CAP 2 METER FROM
STUB TWO CONDUITS 20M ACROSS
1:1000
10 10 20 30 40 50 60 70 80 900
1:1000
10 10 20 30 40 50 60 70 80 90
SCALE = 1:1000
SITE COMMUNICATIONS
MH13
MH12
LHH3
MH15
HH15
LHH1
LHH4
LHH2
HH14
LHH5
MH14
TRENCH
CABLE
XX XX
X X
X XX
X X
X
PAD
EQUIPMENT
PAD
EQUIPMENT
HH12B
DWG. XT-504
REFER TO TYPE 7
DUCT TYPE NOT USED
/2 /2
A M
E N
D M
E N
T
-S
IT
E
X T P
N
MH10
MH11
TOWER
COMO
HAND HOLE
POP
NTS
COMM RM 108
ECS BLDG
6 DUCTS
4 DUCTS
CABLE TRAY
OUTSIDE
3 DUCTS
6 DUCTS
PVC DUCTS
10-100mm
9 DUCTS
CAPPED CONDUIT
SHEET ID
X fi
Middle East District of Engineers
US Army Corps
U S A rm y C o rp s o f
E n g in e e rs
M id d le E a s t
D is tr ic t
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
A
B
M A
R K
A P
P R
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
-0
-1
A
IR
D
E F
E N
S E I
M P
R O
V E
M E
N
S P
E C
IF
IE
D W
O R
L D
W
ID
-4
KEY PLAN
GENERAL SHEET NOTES
NN
CONTINUED ON SHEET XT101
CONTINUED ON SHEET XT103
D A
V E C
L A
R K
E
F G
C H
C H
C h ie f, E le c tr ic a l B ra n c h
S
IT
E T
E L E
C O
M M
U N
IC
A T
IO
N S
XT-102
S
IT
E
A
L J
DWG. XT-504
REFER TO TYPE 1
DWG. XT-505
REFER TO TYPE 4
DWG. XT-506
REFER TO TYPE 6
DWG. XT-507
REFER TO TYPE 13
DWG. XT-507
REFER TO TYPE 14
5 7
DUCT TYPES NOT USED
MH11
TOWER
COMO
X X
X
MH11
TOWER
COMO
HAND HOLE
POP
X X
CONTINUED ON SHEET XT101
MH11
TOWER
COMO
X X
MH11
TOWER
COMO
HAND HOLE
POP
X X
ICC SUNSHADE
CONTINUED ON SHEET XT101
MH11
TOWER
COMO
X X
MH11
TOWER
COMO
HAND HOLE
POP
X X
ICC SUNSHADE
CONTINUED ON SHEET XT101
MH11
TOWER
COMO
X X
HH 7
MH 7
MH 6
MH 5
DWG. XT-504
REFER TO TYPE 2
2M FROM ROAD
STUB TWO (2) CONDUITS
1:1000
10 10 20 30 40 50 60 70 80 900
1:1000
10 10 20 30 40 50 60 70 80 90
SCALE = 1:1000
SITE COMMUNICATIONS
ICC SUNSHADEICC SUNSHADEICC SUNSHADEICC SUNSHADEICC SUNSHADE
A M
E N
D M
E N
T
/2 /2
-S
IT
E
X T P
N
MH9
MH4MH 3
MH 8
HH 2
MH1
MH 2
M E C
C A
X X
X XX XX
M E C
C A
M E C
C A
(OPTION)
HIGH BAY
MAINTENANCE
(OPTION)
(4 ROWS OF 14)
PARKING
COVERED
ADDITIONAL
(OPTION)
BUILDING
PRAYER
SHEET ID
X fi
Middle East District of Engineers
US Army Corps
U S A rm y C o rp s o f
E n g in e e rs
M id d le E a s t
D is tr ic t
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
/3 /2 c u s e r s n e n e d b i\ d o c u m e n t s p w w o r k d
S
IT
E
X T
P N
.d g n n e n e d b i
-0
-1
A
IR
D
E F
E N
S E I
M P
R O
V E
M E
N
S P
E C
IF
IE
D W
O R
L D
W
ID
-4
KEY PLAN
GENERAL SHEET NOTES
NN
CONTINUED ON SHEET XT102
D A
V E C
L A
R K
E
F G
C H
D I
C h ie f, E le c tr ic a l B ra n c h
S
IT
E T
E L E
C O
M M
U N
IC
A T
IO
N S
XT-103
S
IT
E
A
L J
TO GUARD TOWER
DWG. XT-504
REFER TO TYPE 1
DWG. XT-506
REFER TO TYPE 6
DWG. XT-507
REFER TO TYPE 10
DWG. XT-507
REFER TO TYPE 12
6 106
3 METERS FROM THE MH/HH.
THE CONDUITS SHALL STUB OUT
IF OPTIONS ARE NOT EXCERCISED
5 7 DUCT TYPES NOT USED
1:1000
10 10 20 30 40 50 60 70 80 900
1:1000
10 10 20 30 40 50 60 70 80 90
SCALE = 1:1000
SITE COMMUNICATIONS
-S
IT
E
X T P
N
A M
E N
D M
E N
T
/2 /2
TRENCH WALL
76mm 114mm 76mm 76mm114mm
114mm
114mm
76mm
76mm
456mm
304mm
76mm
305mm
DUCT SPACERS
NOT TO SCALE
THREE-WAY TERMINATOR
B
GENERAL NOTES:
581mm
NOT TO SCALE
DUCT TERMINATORS
2. REINFORCING BARS WILL BE INSTALLED BETWEEN THE TERMINATORS.
REQUIRED BY DUCT CONFIGURATION.
1. TERMINATORS SHALL BE CONNECTED ("INTERLOCKED") TO FORM PANELS AS
213mm
194mm
387mm
213mm
194mm114mm
102mm
213mm
775mm
FOUR-WAY TERMINATOR
TERMINATOR DEPTH
TWO-WAY TERMINATOR
CONTINUOUS WITH DUCTBANK
95mm COPPER GROUNDWIRE, PROPERLY COMPACTED SOIL
FINISHED GRADE
MINIMUM
609mm
1557, PROCEDURE C.
DETERMINED BY ASTM D
MAXIMUM DENSITY AS
COMPACT TO 95%
BY ASTM D 2487;
SW,SP AS DETERMINED
150mm LOOSE LIFT OF
NOTE: SPACERS TO BE USED ONLY
IN CONCRETE ENCASEMENT.4. DUCT TERMINATORS TO BE ONE PIECE ABS PLASTIC.
114mm 114mm 76mm 76mm114mm152mm
75mm WIDE
DETECTIBLE
WARNING TAPE
#6, INSULATED TRACER WIRE .
OD) CONDUIT.
3. DUCT TERMINATORS WILL BE SIZED FOR 114mm OUTER DIAMETER (4.5 INCH
TERMINATORS IN THE WALLS.
REFER TO APPENDIX A OF SECTION 33 72 00 FOR ONE METHOD OF CASTING THE
5. DUCT TERMINATORS TO BE CAST INTO THE WALLS/WINDOWS OF THE STRUCTURE.
TRENCH WALL
76mm114mm76mm76mm 114mm
114mm
114mm
76mm
76mm
646mm
304mm
76mm
305mm
CONTINUOUS WITH DUCTBANK
95mm COPPER GROUNDWIRE, PROPERLY COMPACTED SOIL
FINISHED GRADE
MINIMUM
609mm
1557, PROCEDURE C.
DETERMINED BY ASTM
MAXIMUM DENSITY AS
COMPACT TO 95%
BY ASTM D 2487;
SW,SP AS DETERMINED
150mm LOOSE LIFT OF
114mm114mm76mm 152mm
75mm WIDE
DETECTIBLE
WARNING TAPE
CONCRETE ENCASED DUCTBANK (TYPE 7)
NOT TO SCALE
912mm
76mm
114mm
#6, INSULATED TRACER WIRE
SHEET ID
X fi
Middle East District of Engineers
US Army Corps
U S A rm y C o rp s o f
E n g in e e rs
M id d le E a s t
D is tr ic t
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
/2 /2 c u s e r s n e n e d b i\ d o c u m e n t s p w w o r k d
S
IT
E
X T
D T .d g n n e n e d b i
-0
-1
A
IR
D
E F
E N
S E I
M P
R O
V E
M E
N
S P
E C
IF
IE
D W
O R
L D
W
ID
-4
S
IT
E
A
L J
D A
V
ID
S
C L
A R
K E P .E
F G
C H
D I
C h ie f, E le c tr ic a l B ra n c h
XT-504
D U
C T B
A N
K D
E T
A
IL
XT-102
XT-103
XT-102
-S
IT
E
X T
D T
CONCRETE ENCASED DUCTBANK (TYPE 1)
NOT TO SCALE
A M
E N
D M
E N
T
/2 /2
TRENCH WALL
76mm76mm
114mm
114mm
76mm
76mm
646mm
304mm
76mm
305mm
CONTINUOUS WITH DUCTBANK
95mm COPPER GROUNDWIRE, PROPERLY COMPACTED SOIL
FINISHED GRADE
MINIMUM
609mm
1557, PROCEDURE C.
DETERMINED BY ASTM
MAXIMUM DENSITY AS
COMPACT TO 95%
BY ASTM D 2487;
SW,SP AS DETERMINED
150mm LOOSE LIFT OF
114mm114mm76mm
75mm WIDE
DETECTIBLE
WARNING TAPE
NOT TO SCALE
456mm
76mm
114mm
TRENCH WALL
76mm114mm
114mm
114mm
76mm
76mm
456mm
304mm
76mm
305mm
CONTINUOUS WITH DUCTBANK
95mm COPPER GROUNDWIRE, PROPERLY COMPACTED SOIL
FINISHED GRADE
MINIMUM
609mm
1557, PROCEDURE C.
DETERMINED BY ASTM
MAXIMUM DENSITY AS
COMPACT TO 95%
BY ASTM D 2487;
SW,SP AS DETERMINED
150mm LOOSE LIFT OF
114mm 152mm
75mm WIDE
DETECTIBLE
WARNING TAPE
NOT TO SCALE
532mm
76mm
TRENCH WALL
76mm114mm76mm114mm
114mm
76mm
76mm
266mm
304mm
305mmPROPERLY COMPACTED SOIL
FINISHED GRADE
MINIMUM
609mm
1557, PROCEDURE C.
DETERMINED BY ASTM
MAXIMUM DENSITY AS
COMPACT TO 95%
BY ASTM D 2487;
SW,SP AS DETERMINED
150mm LOOSE LIFT OF
114mm114mm76mm 152mm
75mm WIDE
DETECTIBLE
WARNING TAPE
NOT TO SCALE
912mm
76mm
CONTINUOUS WITH DUCTBANK
95mm COPPER GROUNDWIRE, TRENCH WALL
114mm
76mm
266mm
304mm
76mm
305mm
NOT TO SCALE
CONTINUOUS WITH DUCTBANK
95mm† COPPER GROUNDWIRE, PROPERLY COMPACTED SOIL
FINISHED GRADE
MINIMUM
609mm
1557, PROCEDURE C.
DETERMINED BY ASTM D
MAXIMUM DENSITY AS
COMPACT TO 95%
BY ASTM D 2487;
SW,SP AS DETERMINED
150mm LOOSE LIFT OF
114mm 76mm 76mm114mm
75mm WIDE
DETECTIBLE
WARNING TAPE
456mm
76mm
CONCRETE ENCASED DUCTBANK (TYPE 12)
CONCRETE ENCASED DUCTBANK (TYPE 9) CONCRETE ENCASED DUCTBANK (TYPE 10)
CONCRETE ENCASED DUCTBANK (TYPE 11)
#6, INSULATED TRACER WIRE
#6, INSULATED TRACER WIRE
#6, INSULATED TRACER WIRE
FOR MULTIDUCT LOCATIONS.
REFER TO MANHOLE/HAND HOLE DETAILS
GENERAL NOTE:
TRENCH WALL
76mm114mm76mm76mm 114mm
114mm
114mm
76mm
76mm
646mm
304mm
76mm
305mm
CONTINUOUS WITH DUCTBANK
95mm COPPER GROUNDWIRE, PROPERLY COMPACTED SOIL
FINISHED GRADE
MINIMUM
609mm
1557, PROCEDURE C.
DETERMINED BY ASTM
MAXIMUM DENSITY AS
COMPACT TO 95%
BY ASTM D 2487;
SW,SP AS DETERMINED
150mm LOOSE LIFT OF
114mm114mm76mm76mm 114mm
1,102mm
152mm
75mm WIDE
DETECTIBLE
WARNING TAPE
NOT TO SCALE
CONCRETE ENCASED DUCTBANK - TYPE 13
#6, INSULATED TRACER WIRE
TRENCH WALL
76mm114mm76mm76mm 114mm
114mm
114mm
76mm
76mm
646mm
304mm
76mm
305mm
CONTINUOUS WITH DUCTBANK
95mm COPPER GROUNDWIRE, PROPERLY COMPACTED SOIL
FINISHED GRADE
MINIMUM
609mm
1557, PROCEDURE C.
DETERMINED BY ASTM
MAXIMUM DENSITY AS
COMPACT TO 95%
BY ASTM D 2487;
SW,SP AS DETERMINED
150mm LOOSE LIFT OF
114mm
75mm WIDE
DETECTIBLE
WARNING TAPE
NOT TO SCALE
#6, INSULATED TRACER WIRE
646mm
76mm
CONCRETE ENCASED DUCTBANK - TYPE 14
SHEET ID
X fi
Middle East District of Engineers
US Army Corps
U S A rm y C o rp s o f
E n g in e e rs
M id d le E a s t
D is tr ic t
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
/2 /2 c u s e r s n e n e d b i\ d o c u m e n t s p w w o r k d
S
IT
E
X T
D T .d g n n e n e d b i
-0
-1
A
IR
D
E F
E N
S E I
M P
R O
V E
M E
N
S P
E C
IF
IE
D W
O R
L D
W
ID
-4
S
IT
E
A
L J
D A
V
ID
S
C L
A R
K E P .E
F G
C H
D I
C h ie f, E le c tr ic a l B ra n c h
XT-507
D U
C T B
A N
K D
E T
A
IL
XT-101
XT-103
XT-102
XT-102
XT-102
XT-101
XT-103
XT-102
XT-101
-S
IT
E
X T
D T
(NOT USED)
A M
E N
D M
E N
T
/2 /2
X fi
Middle East District of Engineers
US Army Corps
U S A rm y C o rp s o f
E n g in e e rs
M id d le E a s t
D is tr ic t
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
/4 /2 c u s e r s n e n e d b i\ d o c u m e n t s p w w o r k d
S
IT
E
X T
D I0
.d g n n e n e d b i
-0
-1
A
IR
D
E F
E N
S E I
M P
R O
V E
M E
N
S P
E C
IF
IE
D W
O R
L D
W
ID
-4
DIM. NOTE & NORTH
NN
S
IT
E
A
L J
D A
V
ID
S
C L
A R
K E P .E
D I
C H
D I
C h ie f, E le c tr ic a l B ra n c h
S
IT
E C
O M
M U
N
IC
A T
IO
N S
O N
E L
IN
E D
IA
G R
A M
XT-601
CONTROL MODULE
ICC/ECS
PDU
STORAGE
PDU
PDU
LAUNCHERS
SITE COMMUNICATIONS
ONE LINE DIAGRAM
TOWER
GUARD
TOWER
GUARD
TOWER
GUARD HQ
LAUNCHERS
LAUNCHERS
LAUNCHERS
LAUNCHERS
PRAYER BUILDING
1, 1-6
P6x-24 PF
PLANT
POWER
ECP
2, 1-6
P6x-24 PF
2, 7-12
P6x-24 PF
LEFT IN CLOSURE
CLEARED AND CAPPED
CABLE 2, PAIRS 13-25
2,1-25
P25x-24PF
FCOMM, 1-48, 48 SM
1, 1-100
P1-24PF
NON TACTICAL CABLE SYSTEM
2, 26-31
P6x-24 PF
2, 32-43
P12x-24 PF
CAPPED
CLEARED AND
PAIR 50
1, 20-25
P6x-24 PF
CAPPED
CLEARED AND
PAIRS 7-19
2, 44-49
P6x-24 PF
FSV, 1-24, 24 SM
FSV, 1-24, 24 SM
FCOMM, 1-48, 48 SM
(POINT OF PRESENCE)
POP HANDHOLE
MH 6
MH 5
MH 4
MH 3
MH 8
MH 7HH 7
MH 10
MH 1
MH 2
NOT TO SCALE, LOCATIONS ARE GENERAL
MH 11
MH 12
MH 13
MH 14
HH 14
MH 15
HH 15
1,1-100
P1-24PF
1,1-25
P25-24PF
1,1-25
P25-24PF
CAMERAS
TOWER
GUARD
CAMERAS
CAMERAS
CAMERAS
PROVIDED BY THE CONTRACTOR.
MEDIA CONVERTERS FOR THE CAMERAS TO BE
TO BE BROKEN OUT IN THE TERMINAL CABINET (s). ANY
TO THE TOWER AND ECP. STRANDS TO EACH CAMERA
MULTI-DUCTS. ONE FIBER CABLE TO BE INSTALLED
NOT SHOWN BUT WILL BE INSTALLED IN ONE OF THE 38mm
1. SOUTH TOWERS: CABLE FROM THE SECURITY CAMERAS ARE
REQUIREMENTS.
REFER TO SECTION 27 10 00 FOR THE FIBER OPTIC HARDWARE
CONVERSION, ECT.) TO MAKE THE CAMERAS OPERATIONAL.
SPLICED PIGTAILS AND ALL OTHER HARDWARE (MEDIA
TO ALSO CONTAIN A FIBER PATCH PANEL, SPLICE TRAY, FUSION
HARDWARE REQUIRED TO POWER THE CAMERAS. ENCLOSURE
VOLTAGE PROTECTION, TRANSFORMERS ECT.) AND ALL OTHER
EQUIPPED WITH POWER EQUIPMENT (OVER CURRENT/OVER
TO BE BROKEN OUT IN THE ENCLOSURE. ENCLOSURE TO BE
BASE OF THE LIGHT POLE. STRANDS TO EACH CAMERA
CABLE TO BE INSTALLED TO A NEMA 4 ENCLOSURE AT THE
MULTI-DUCTS FROM A HANDHOLE (HH 14 , HH 15). ONE FIBER
NOT SHOWN BUT WILL BE INSTALLED IN ONE OF THE 38mm
2. NORTH TOWERS: CABLE FROM THE SECURITY CAMERAS ARE
HH 2
FCM 3, 1-18,18SM
FCM 3,1-24, 24 SM
LEFT IN SPLICE CLOSURE
FCM 3, 19-24
FCM 3,1-24, 24 SM
FCM 3,1-24, 24 SM
FCM 1, 1-48, 48 SM
FCM 1,1-48, 48 SMFCM 1,1-48, 48 SM
FCM 1,1-48, 48 SM
FCM 1,1-48, 48 SM
FCM 1,1-24, 24 SM
FCM 1,1-18, 18 SM
FCM 1, 25-48, 48 M
FCM 1,25-48, 24 SM
IN SPLICE CLOSURE
FCM 1,19-24
FCM 1,25-42, 18 SM
IN SPLICE CLOSURE
FCM 1,42-48
AND CAPPED
1-25 CLEARED
2,26-100 +
P1-24PF
FCM 2,1-24, 24 SM
FCM 2,1-18, 18 SM
FCM 2,19-24, 24 SM
FCOMM, 1-48, 48 SM
FSV, 1-24, 24 SM
2, 1-6
P6x-24 PF
FCM 1
FIBER SPLICE
2, 51-75, 51-56 DD
P25X-24 PF
1,1-100 (TO ECS)
P1-24PF
2, 26-100, 1-25 DD
P1-24PF
FCM 2, 1-24, 24 SM
DD = DEAD PAIR COUNT
HH12AHH12B
SHEET NOTES
-S
IT
E
X T
D I0
FCM FIBER, CAMERAS, (CONSTRUCTION CONTRACT).
FSV FIBER, SECURE VOICE, (CONSTRUCTION CONTRACT)
A M
E N
D M
E N
T
/2 /2
FCOMM FIBER (CONSTRUCTION CONTRACT)
(48 SM) - 48 STRAND, SINGLE MODE
(1-48) - FIBER STRAND COUNT
(FCOMM) - CABLE IDENTIFIER
FCOMM, 1-48, 48 SM,
FIBER CABLE
(1) - CABLE NUMBER, (1-25) - PAIR COUNT
(PF) - POLYETHYLENE FOAM SKINNED INSULATION
(24) - 24 AWG CABLE
(12x) - PAIR SIZE OF CABLE, x SIGNIFIES LESS THAN 25 PR
(P) - POLYETHYLENE INSULATED CONDUCTOR
1, 1-25
P-12x-24 PF
COPPER CABLE
3. CABLE LEGEND:
A
B
T/CONC
[3000]
200 mm CONC SLAB
REINF. WITH D16@
250 OC EW T&B
S-503
S-503
S-503
200 CONC WALL
REINF W/ D12@
400 EW (TYP)
TYP
MBS FRAME ABOVE
MASONRY WALL BELOW
PEDESTRIAN
BRIDGE BY MBS
MANUF
BEAM TO SUPPORT COLUMN
ABOVE BY MBS
MANUFACTURER
STAIRS BY MBS
MANUF
A
B
DEPRESSED SLAB,
SEE DETAIL 2/SS-508
T/CONC
[-60]
FD
T/CONC
[-60]
T/CONC
[-55]
T/CONC
[-55]
S-502
S-502
150 SLAB-ON-
GRADE REINF W/
D12@400 EW TOP
W F3
F1
WF2
S-503
W F4
STAIR AND
PEDESTRIAN BRIDGE
FRAMING BY MBS
MANUF. (TYP)
U P
500 MAT SLAB REINF
WITH D16@350 T&B EW
SLAB OPENING FOR EASTERN
STYLE TOILET. SEE ARCH AND
MECH FOR SIZE AND LOCATION.
SS-501
FD
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5 8/
3/
:2 0:
P
M
8/ 3/
:2
0:
PM
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
- C O
N
TR
AC
T
N U
M
BE
R
Middle East District
ES
P
ES
P
JE
FF
ER
Y
P . R
AN
EY
, C H
EI
F
A C
H
IT
EC
TU
R
AL
B R
AN
C
H
A
-S F4
P
N
S-401
W
IN
C H
E
ST
E R
, V A
R
LT
EN
LA
R G
ED
S
TR
UC
TU
R
AL
P
LA
N
S
A
P2 -4
EN
G
A G
EM
EN
T C
O
NT
RO
L
ST
A
TI
O
N
1 : 20
ENLARGED ROOF FRAMING PLAN - SITE 06 - ALJ
1 : 20
ENLARGED FOUNDATION PLAN - SITE 06 - ALJ
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A M
E N
D M
EN
T
#4
/0 2/
UP
70mmSQ BURIED BARE COPPER GROUND WIRE 760mm BELOW GRADE, 1.5M FROM THE BUILDING. ALL
CONNECTIONS SHALL BE EXOTHERMIC (TYP)
ROOF MOUNTED LIGHTNING
PROTECTION AIR TERMINAL
±7.5M APART FOR PERIMETER
OF THE ROOF (TYP)
GROUND ROD 16mm DIAMETER, 3.6M LONG. SEE DETAIL ON SHEET SE-502
PROVIDE
GROUND ROD WITH
INSPECTION WELL
70mmSQ BARE COPPER DOWN CONDUCTOR (TYP)
±15M APART IN THE
MIDDLE OF THE ROOF
AND RIDGES
ROOF MOUNTED
LIGHTNING PROTECTION
AIR TERMINAL
70mmSQ BARE
COPPER ROOF
CONDUCTOR (TYP)
R
R
R R R R
R
R
R
R R R D
D
D
D
D
D D D
D D
D
D
D
D
DDDDDDD
D
D
D
M A
TC
H
LI
N
E E
-1
M A
TC
H
LI
N
E E
-1
D
D
BOND WITH MAIN
DISTRIBUTION
PANEL " MDPA"
PROVIDE CONNECTION
BETWEEN BUILDING
STEEL AND GROUNDING
RING. (TYP)
D
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5 8/
3/
:3 3:
P
M
8/ 3/
:3
3:
PM
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
- C O
N
TR
AC
T
N U
M
BE
R
Middle East District
IA IA D
AV
E S
. C
LA
R
KE
A
-E P
6P
N
E-106
W
IN
C H
E
ST
E R
, V A
M M
G R
O
UN
D
IN
G A
ND
L
IG
HT
N
IN
G P
RO
TE
C
TI
O N
P L A
N
A
P2 -4
EN
G
A G
EM
EN
T C
O
NT
RO
L
ST
A
TI
O
N
1 : 100
GROUNDING AND LIGHTNING PROTECTION PLAN- SITE 6
GENERAL NOTES:
1. REFER TO SE-001 FOR ELECTRICAL LEGEND,GENERAL
NOTES AND ABBREVIATIONS.
2.REFER TO SE-502 AND SE-503 FOR GROUND ROD,
GROUNDING, BONDING AND AIR TERMINAL DETAILS.
GROUNDING PLAN NOTES:
1. PROVIDE DOWN CONDUCTOR TO GROUNDING
COUNTERPOISE OR CONNECT TERMINAL TO STRUCTURAL
STEEL FRAME.
2. IT IS CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT
THE DESIGN AND INSTALLATION OF GROUNDING AND
LIGHTNING PROTECTION SYSTEM IS IN ACCORDANCE
WITH NEW R-1 AND S-1.
3. PROVIDE CONNECTION FROM ALL ROOF MOUNTED
MECHANICAL EQUIPMENT TO GROUNDING RING USING
70mmSQ BARE COPPER GROUND WIRE.
1:100
10m2m 8m6m4m0m
SHEET NOTES:
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A M
E N
D M
EN
T
#4
/0 2/
GROUND ROD 16mm DIAMETER, 3.6M LONG. SEE DETAIL ON SHEET SE-502
R R R R R
R
R
RRR
R R R R R
D D D D D D D
D D
D
D
D
D
D
DDDDDDDD
M A
TC
H
LI
N
E E
-1
M A
TC
H
LI
N
E E
-1
70mmSQ BURIED BARE COPPER GROUND WIRE 760mm BELOW GRADE, 1.5M FROM THE BUILDING. ALL
CONNECTIONS SHALL BE EXOTHERMIC (TYP)
ROOF MOUNTED LIGHTNING
PROTECTION AIR TERMINAL
±7.5M APART FOR PERIMETER
OF THE ROOF (TYP)
±15M APART IN THE MIDDLE OF THE
ROOF AND RIDGES
70mmSQ BARE
COPPER ROOF
CONDUCTOR (TYP)
D
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
SHEET OF
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5 8/
3/
:3 4:
P
M
8/ 3/
:3
4:
PM
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
- C O
N
TR
AC
T
N U
M
BE
R
Middle East District
IA IA D
AV
E S
. C
LA
R
KE
A
-E P
7P
N
E-107
W
IN
C H
E
ST
E R
, V A
M M
G R
O
UN
D
IN
G A
ND
L
IG
HT
N
IN
G P
R O
TE
C
TI
O N
P L A
N
A R
EA
B
A
P2 -4
EN
G
A G
EM
EN
T C
O
NT
RO
L
ST
A
TI
O
N
1 : 100
GROUNDING AND LIGHTNING PROTECTION PLAN "AREA B"- SITE 6
GENERAL NOTES:
1. REFER TO SHEET SE-001 FOR ELECTRICAL
LEGEND,GENERAL NOTES AND ABBREVIATIONS.
2.REFER TO SE-502 AND SE-503 FOR GROUND ROD,
GROUNDING, BONDING AND AIR TERMINAL DETAILS.
GROUNDING PLAN NOTES:
1. PROVIDE DOWN CONDUCTOR TO GROUNDING
COUNTERPOISE OR CONNECT TERMINAL TO STRUCTURAL
STEEL FRAME.
2. IT IS CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT
THE DESIGN AND INSTALLATION OF GROUNDING AND
LIGHTNING PROTECTION SYSTEM IS IN ACCORDANCE
WITH NEW R-1 AND S-1.
3. PROVIDE CONNECTION FROM ALL ROOF MOUNTED
MECHANICAL EQUIPMENT TO GROUNDING RING USING
70mmSQ BARE COPPER GROUND WIRE.
1:100
10m2m 8m6m4m0m
SHEET NOTES:
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A M
E N
D M
EN
T
#4
/0 2/
COMM.
OFFICE
105OFFICE
OFFICE
OFFICE
101D
ECS
PARKING
PARTS
101E
FC ROOM
ICC SUN SHADE
ENLISTED TOILET
101B
OFFICER TOILET
101C
CABLE LADDER:
610mm (WIDTH) x 178mm (DEPTH) 5486mm AFF
PROPOSED LOCATION
FOR FSAMG PATCH PANEL
(NOT TO SCALE)
INSTALL TGB BELOW PP
457mm AFF.
PROPOSED LOCATION FOR THE TLPJB
CONNECTION BOX . (NOT TO SCALE)
CABLE LADDER:
610MM (WIDTH) x 178mm (DEPTH)
2743.2 AFF VERTICALLY MOUNTED
CABLE LADDER:
610mm (WIDTH) x 178mm (DEPTH)
5486 AFF
CABLE LADDER:
610MM (WIDTH) x 178mm (DEPTH)
5486 AFF
CABLE LADDER:
152MM (WIDTH) x 100mm (DEPTH)
2268 AFF
TERMINATOR PANEL
LOCATION CUSTOMER
TO INSTALL TERMINATOR
PANEL
610mm x 178mm
LADDER TYPE
CABLE TRAY, 229mm
BETWEEN RUNGS
FUTURE RACKS
RED SYSTEM
CUSTOMER
INSTALLED RACKS
BLACK SYSTEM
LADDER CABLE TRAY FROM TOWER
(610mm X 178mm). CABLE LADDER
WITH COVER SHALL BE SUPPORTED
VIA THE METHOD DESIGNATED BY
THE TOWER INSTALLERS.
152mm PIPE SLEEVE
FOR CUSTOMER
INSTALLED CABLE
PLASTIC BUSHING
TO BE PROVIDED
FLUSH WITH OUTSIDE
WALL
TWO (2) 51mm STEEL CONDUITS
WITH PLASTIC BUSHING ABOVE
FALSE CEILING, FIRE STOP AS
REQUIRED
RAYTHEON INSTALLED CABLE
TO DROP DOWN FROM WALL
MOUNTED VERTICAL CABLE
LADDER TO HORIZONTAL TRAPEZE
MOUNTED CABLE LADDER TO
TERMINATOR PANEL
CUSTOMER INSTALLED CABLE
TO DROP DOWN FROM WALL
MOUNTED VERTICAL CABLE
LADDER TO HORIZONTAL TRAPEZE
MOUNTED CABLE LADDER TO
TERMINATOR PANEL
TRANSITION FROM 5486 AFF
TO 3300 AFF
T-211 1
T-211 2
T-211
T-211 4
INSTALL GROUND BAR (TGB) BELOW THE CONNECTION BOX.
MOUNT TGB 457mm ABOVE FINISHED GRADE. CONNECT TO
BLDG GROUND VIA CABLE SIZED IAW ANSI EIA/TIA 607.
INSTALL GROUND BAR (TGB) 152mm BELOW THE SCREEN ROOM
PENETRATION PLATE. CONNECT TO BUILDING GROUND BAR
IN MDPA6 VIA GROUND CABLE SIZED IAW ANSI EIA/TIA 607.
INSTALL A 16mm2 COPPER CONDUCTOR FROM THE TGB TO A LOCATION 152mm BELOW EACH OF THE FOUR (4) ROOM
PENETRATION PLATE[S]. TERMINATE CABLE IN A ONE-HOLE LUG
BOLTED TO THE TOP OF AN INSULATOR.
INSTALL GROUND BAR
(TGB) 457mm AFF FOR
CONNECTION TO CABLE
LADDER SYSTEM.
INSTALL GROUND BAR (TGB) BELOW THE FSAMG PATCH PANEL.
MOUNT TGB 457mm ABOVE FINISHED GRADE. CONNECT TO
BLDG GROUND VIA CABLE SIZED IAW ANSI EIA/TIA 607.
NOTE 1: INSTALL A GROUND BAR ON BOTH CABLE LADDER
SECTIONS IN THE SCREEN ROOM. CONNECT THE CABLE LADDER
GROUND BARS TO THE WALL-MOUNTED TGB IN THE SCREEN
ROOM.
NOTE 1
NOTE 1
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5 8/
4/
:1 4:
A
M
8/ 4/
:1
4:
AM
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
- C O
N
TR
AC
T
N U
M
BE
R
Middle East District
C H
D I
D
AV
E S
. C
LA
R
KE
A
-T N
2P
N
T-102
W
IN
C H
E
ST
E R
, V A
D I
TE
LE
C O
M M
U N
IC
A
T I O
N S
C A
BL
E
T R A
Y
PL
A N
SI
TE
A
P2 -4
EN
G
A G
EM
EN
T C
O
NT
RO
L
ST
A
TI
O
N
1 : 100
TELECOM CABLE TRAY PLAN - SITE 6
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A M
E N
D M
EN
T
#3
/2 5/
A
M E
N D
M
EN
T #4
/0
2/
1:100
10m2m 8m6m4m0m
SHEET NOTE:
ON CABLE TRAYS LABELED WITH 178mm DEPTH.
178mm IS THE PHYSICAL DEPTH, 152mm IS THE
CABLE LOADING DEPTH.
W
W
W
W
W W
TV
S
TV
TV
TV
TV
TV
TV
TV
TV
TV
TV
TV
TV
ELEC.
COMM.
106E
T-401
T-402
VESTIBULE
ENTRY
CORR.
OFFICE
OPS
OFFICE
OFFICE
106I
TOILET
106G
MECH.
106F JAN.
106H
ENLISTED
BARRACKS
STORAGE
ELEC.
COMM.
106E
KITCHEN
LECTURE HALL
SECURITY
106D
ARMS
103AMMO
106C
OFFICER
BREAK RM
OFFICE
CONTROL
CENTER
OFFICE
OFFICE SUITE
OFFICE
TOILET
114A
ELEC.
KITCHEN
MECH.
FIRST AID
RM.
JAN.
ENTRY
VEST
CORR.
VEST
COMM
T-421
T-421
T-411
T-411
CABLE TRAY
152mm x 100mm 3050mm AFF 4
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5 8/
2/
:4 8:
P
M
8/ 2/
:4
8:
PM
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
- C O
N
TR
AC
T
N U
M
BE
R
Middle East District
C H
D I
D
AV
E S
. C
LA
R
KE
B
-T N
1P
N
T-101
W
IN
C H
E
ST
E R
, V A
D I
TE
LE
C O
M F
LO
O
R P
LA
N
SI
TE
B
P2 -4
H
EA
DQ
UA
R
TE
RS
B
U I
LD
IN
G
1 : 100
GROUND FLOOR PLAN - SITE 6
1:100
10m2m 8m6m4m0m
NOTE 1: COMMUNICATIONS OUTLETS SHALL BE PLACED
450mm AFF AND SHALL BE CONNECTED TO THE CABLE TRAY SYSTEM WITH 25mm CONDUIT.
NOTES:
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A M
E N
D M
EN
T
#4
-0 2-
NOTE 2: COMMUNICATIONS CABLE TRAY SHALL BE
152mm x 100mm, 3050 AFF UNLESS OTHERWISE NOTED.
SECURE VOICE
EQUIPMENT
RACK
VOICE/DATA
EQUIPMENT
RACK
CUSTOMER
USE
EQUIPMENT
RACK #2
CUSTOMER
USE
EQUIPMENT
RACK #1
OSP / FIBER
EQUIPMENT
RACK
48ST SM
FEED
2 - 100 PR PETs
DISTRIBUTION
(STACKED)
P E T
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5 8/
2/
:5 9:
P
M
8/ 2/
:5
9:
PM
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
- C O
N
TR
AC
T
N U
M
BE
R
Middle East District
D I
D I
D
AV
E S
. C
LA
R
KE
B-
TN
1L S
T-401
W
IN
C H
E
ST
E R
, V A
C H
EN
LA
R G
ED
T
EL
EC
O M
R M
SI
TE
B
P2 -4
H
EA
DQ
UA
R
TE
RS
B
U I
LD
IN
G
NOTE 1: STANDARD CABLE LADDER SHALL BE 300mm WIDTH X 100 HEIGHT PLACED AT 3050mm AFF (ABOVE
FINISHED FLOOR).
NOTE 2: SECURE VOICE CABLE PDS SHALL BE 86mm WIDTH X 152mm HEIGHT PLACED AT 2850 AFF.
NOTE 3: A TOTAL OF TEN (10) - 100mm CONDUIT STUB-UPS
EXTEND TO MH-1. MH-1 SHALL HAVE 3 X 3 AND 2 X 2 DUCT
WINDOWS CONNECTING TO THE HQ BLDG (SEE XT-513).
NOTES
1 : 20T-101
1 CABLE LADDER PLAN - COMM RM 119 - SITE 6
1 : 20
COMMUNICATIONS ROOM LAYOUT AND RACK PLAN - COMM RM 119 - SITE 6
10 - 100mm CONDUIT
STUB-UPS
SECURE VOICE
PDS
CABLE TRAY
TMGB
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A M
E N
D M
EN
T
#3
/2 5/
A
M E
N D
M
EN
T #4
-0
2-
1:20
2m0.4m 1.6m1.2m0.8m0m
R C
D W
P
R C
D W
P
C
C
C C
C
C C
C
C
CU-H- 1
STORAGE FACILITY
WP
CU-H
CU-H- 2
STORAGE FACILITY
GROUND BUS BAR
CONNECT TO GROUNDING LOOP (TYP)
DDDDD
D
D
D D D D D
D
D
RRRR
R
RR
RRRR
R
R
R
70mmSQ BURIED BARE COPPER GROUND WIRE 760mm BELOW GRADE, 1.5M FROM THE BUILDING.
ALL CONNECTIONS SHALL BE EXOTHERMIC (TYP)
ROOF MOUNTED LIGHTNING PROTECTION AIR TERMINAL
±7.5M APART FOR PERIMETER OF THE ROOF (TYP)
PROVIDE GROUND ROD
WITH INSPECTION WELL
70mmSQ BARE
COPPER DOWN
CONDUCTOR (TYP)
±15M APART IN THE
MIDDLE OF THE ROOF
AND RIDGES
ROOF MOUNTED LIGHTNING
PROTECTION AIR TERMINAL (TYP)
70mmSQ BARE
COPPER ROOF
CONDUCTOR (TYP)
GROUND ROD 16mm DIAMETER 3.6M LONG.
SEE DETAIL ON SHEET SE-502. (TYP)
PROVIDE CONNECTION
BETWEEN BUILDING STEEL,
GROUND RING.(TYP)
BOND WITH
" CU-H"
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5 8/
3/
:4 2:
P
M
8/ 3/
:4
2:
PM
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
- C O
N
TR
AC
T
N U
M
BE
R
Middle East District
IA IA D
AV
E S
. C
LA
R
KE
H
-E P
1P
N
E-101
W
IN
C H
E
ST
E R
, V A
M M
LI
G
H
TI
N G
PO
W E R
, G R
O U
N D
IN
G
A N
D L
IG
H
TN
IN
G
PR
O
TE
C
TI
O N
P
LA
N S
H
P2 -4
ST
O
R
AG
E
FA
CI
LI
TY
1 : 100
LIGHTING PLAN
1:100
10m2m 8m6m4m0m
Notes:
Total Est. Demand: 100.00% Total Est. Demand: 6 A Total Est. Demand: 1341 VA
Receptacle 360 VA 100.00% 360 VA Total Connected: 6 A Other 0 VA 0.00% 0 VA Total Conn. Power... 1341 VA Lighting 981 VA 100.00% 981 VA Load Classification Connected... Demand... Estimated... Panel Totals
Total Connected... 6 A Total Connected... 1341 VA
9 Space -- -- 0 VA 8 Space -- -- 0 VA 7 Space -- -- 0 VA 6 Space -- -- 0 VA 5 Spare 16 A -- 0 VA 4 Spare 16 A -- 0 VA 3 Spare 16 A -- 0 VA 2 Sockets ** 20 16 A 1-#4mm², 1-#4mm²,... 360 VA 1 Lighting * 20 16 A 1-#4mm², 1-#4mm²,... 981 VA
Circuit Number Circuit Description Conduit mm
Trip Wire Size Load
Location: STORAGE FACILITY 101 MCCB Trip Rating: 30 A Mounting: Surface Wires: 2 MCCB Rating: 30 A
Supply From: MDPA Phases: 1 Bus Rating: 30 A Enclosure: NEMA 4X Volts: 240 A.I.C. Rating: 10,000 Panel: CU-H
* PROVIDE CURRENT OPERATED EARTH LEAKAGE CIRCUIT BREAKER WITH 300 MILLIAMPS EARTH
LEAKAGE PROTECTION.
** PROVIDE CURRENT OPERATED EARTH LEAKAGE CIRCUIT BREAKER WITH 30 MILLIAMPS EARTH
LEAKAGE PROTECTION.
1 : 100
POWER PLAN
1 : 100
GROUNDING AND LIGHTNING PROTECTION PLAN
GENERAL NOTES:
1. FOR ELECTRICAL NOTES, LEGEND AND ABBREVIATIONS SEE
SHEET SE-001.
2.REFER TO SHEETS SE-504, SE-505 & SE-506 FOR LIGHTING
FIXTURE SCHEDULE, DETAILS AND MORE INFORMATION.
3. REFER TO SHEET SE-502 ANS SE-503 FOR GROUND ROD,
GROUNDING, BONDING AND AIR TERMINALS DETAILS.
POWER PLAN NOTES:
1. ALL EXTERIOR ELECTRICAL EQUIPMENT SHALL BE RATED
NEMA 4X STAINLESS STEEL.
2. FIELD ADJUST LOCATION OF GROUND BUS BAR AS NEEDED.
LIGHTING PLAN NOTES:
1. UPPER CASE LETTER INDICATES FIXTURE TYPES.
2. ALL EXTERIOR LIGHTS SHALL BE CONTROLLED BY
PHOTOCELL.
GROUNDING NOTES:
1. IT IS CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT THE
DESIGN AND INSTALLATION OF GROUNDING SYSTEM IS IN
ACCORDANCE WITH NEW R-1 AND S-1.
2. PROVIDE DOWN CONDUCTOR TO GROUNDING
COUNTERPOISE OR CONNECT TERMINAL TO STRUCTURAL
STEEL FRAME.
3. IT IS CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT THE
DESIGN AND INSTALLATION OF GROUNDING AND LIGHTNING
PROTECTION SYSTEM IS IN ACCORDANCE WITH NEW R-1 AND S-
1.
4. PROVIDE CONNECTION FROM ALL ROOF MOUNTED
MECHANICAL EQUIPMENT TO GROUNDING RING USING 70mmSQ
BARE COPPER GROUND WIRE.
SHEET NOTES:
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A M
E N
D M
EN
T
#4 8/
/2
RCD WP
RCD WP
R C
D W
P
MDPI1
MDPI1- 4
MDPI1- 2
CU-I-1 MDPI1- 5
30 KW FREQUENCY
CONVERTER/PDU
WP
Power to Frequency Converter/PDUGROUNDING BUS BAR (TYP)
CONNECT TO BUILDING GROUNDING SYSTEM
BBB
J
MDPI1- 3
J
MDPI1- 1
70mmSQ BURIED BARE COPPER GROUND WIRE 760mm BELOW GRADE, 1.5M FROM THE BUILDING. ALL
CONNECTIONS SHALL BE EXOTHERMIC (TYP)
GROUND ROD 16mm DIAMETER,3.6M LONG.
R
R
RR
ROOF MOUNTED LIGHTNING PROTECTION AIR TERMINAL
±7.5M APART FOR PERIMETER OF THE ROOF (TYP)
70mmSQ BARE
COPPER ROOF
CONDUCTOR (TYP)
PROVIDE GROUND ROD
WITH INSPECTION WELL
PROVIDE CONNECTION
BETWEEN BUILDING STEEL,
GROUND RING.(TYP)
BOND WITH MAIN
DISTRIBUTION PANEL "MDPI1"
D
DD
D
70mmSQ BARE
COPPER DOWN
CONDUCTOR (TYP)4
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5 8/
3/
:2 2:
P
M
8/ 3/
:2
2:
PM
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
- C O
N
TR
AC
T
N U
M
BE
R
Middle East District
IA IA D
AV
E S
. C
LA
R
KE
I-E
P
1P N
E-101
W
IN
C H
E
ST
E R
, V A
M M
PO
W
ER
, L
IG
H
T I N
G A
ND
G
R O
U N
DI
N
G P
LA
N
I
P2 -4
FR
EQ
UE
NC
Y
CO
N
VE
R
TE
R
PD
U
S
HE
LT
ER
1 : 50
POWER PLAN
1:50
5m1m 4m3m2m0m
1 : 50
LIGHTING PLAN
1 : 50
GROUNDING AND LIGHTNING PROTECTION PLAN
GENERAL NOTES:
1. FOR ELECTRICAL NOTES, LEGEND AND
ABBREVIATIONS SEE SHEET SE-001.
2.REFER TO SHEETS SE-504, SE-505 & SE-506 FOR
LIGHTING FIXTURE SCHEDULE, DETAILS AND MORE
INFORMATION.
3. REFER TO SHEET SE-502 AND SE-503 FOR GROUND
ROD, GROUNDING, BONDING AND AIR TERMINALS
DETAILS.
4. REFER TO SHEET IM-101 AND IM-601 MECHANICAL
DRAWINGS FOR THE SCHEDULES AND EXACT LOCATION
OF MECHANICAL EQUIPMENT.
5.PLANS SHOWN ARE TYPICAL FOR EACH FREQUENCY
CONVERTER/PDU BUILDING.
POWER PLAN NOTES:
1. ALL EXTERIOR ELECTRICAL EQUIPMENT SHALL BE
RATED NEMA 4X STAINLESS STEEL.
2. FIELD ADJUST LOCATION OF GROUND BUS BAR AS
NEEDED.
LIGHTING PLAN NOTES:
1. UPPER CASE LETTER INDICATES FIXTURE TYPES.
2. ALL EXTERIOR LIGHTS SHALL BE CONTROLLED BY
PHOTOCELL.
3. EMERGENCY LIGHTS AND EXIT LIGHTS SHALL BE
CONNECTED AHEAD OF LIGHT SWITCHES.
GROUNDING NOTES:
1. IT IS CONTRACTOR'S RESPONSIBILITY TO ENSURE
THAT THE DESIGN AND INSTALLATION OF GROUNDING
SYSTEM IS IN ACCORDANCE WITH NEW R-1 AND S-1.
2. PROVIDE DOWN CONDUCTOR TO GROUNDING
COUNTERPOISE OR CONNECT TERMINAL TO
STRUCTURAL
STEEL FRAME.
3. IT IS CONTRACTOR'S RESPONSIBILITY TO ENSURE
THAT THE DESIGN AND INSTALLATION OF GROUNDING
AND LIGHTNING PROTECTION SYSTEM IS IN
ACCORDANCE WITH NEW R-1 AND S-1.
4. PROVIDE CONNECTION FROM ALL ROOF MOUNTED
MECHANICAL EQUIPMENT TO GROUNDING RING USING
70mmSQ BARE ALUMINUM GROUND WIRE.
5. FIELD COORDINATE LOCATION OF GROUNDING BUS
BAR WITH THE FINAL PLACEMENT OF TACTICAL
EQUIPMENT, BUS BAR SHALL BE LOCATED WITHIN
300MM OF TACTICAL EQUIPMENT. PROVIDE ADDITIONAL
BUS BARS AS NEEDED TO MEET THIS REQUIREMENT.
SHEET NOTES:
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A M
E N
D M
EN
T
#4
/0 2/
| Sheets |
| T-102 - TELECOMMUNICATIONS CABLE TRAY PLAN - SITE 6 |
| 443309B-SITE06-T10104_n0enedbi.pdf |
| Sheets |
| T-101 - TELECOM FLOOR PLAN - SITE 6 |
| 443309B-SITE06-T40104_n0enedbi.pdf |
| Sheets |
| T-401 - ENLARGED TELECOM RM 119 - SITE 6 |
| 443309-SITE06-XT10104_n0enedbi.pdf |
| 443309-SITE06--XT101PN04 |
| 443309-SITE06-XT10204_n0enedbi.pdf |
| 443309-SITE06--XT102PN04 |
| References |
| 443309-SITE06--XT102PN04.dgn, Model |
| 443309-SITE06-XT10304_n0enedbi.pdf |
| 443309-SITE06--XT103PN04 |
| References |
| REPLACE, 443309-SITE06--XT103PN04.dgn, Model |
| 443309-SITE06-XT50404_n0enedbi.pdf |
| 443309-SITE06--XT504DT04 |
| References |
| Sheet Standards, PW_WORKDIR:dms48248 |
| 2012_drawing template.dgn |
| 443309-SITE06--XT504DT04.dgn, Model |
| PW_WORKDIR:d0552015 |
| 443309-SITE06--XT505DT.dgn, Model |
| 443309-SITE06-XT50704_n0enedbi.pdf |
| 443309-SITE06--XT507DT04 |
| References |
| 443309-SITE06--XT507DT04.dgn, Model |
| 443309-SITE06-XT60104_n0enedbi.pdf |
| 443309-SITE06--XT601DI04 |
| 443309A - S-401.pdf |
| Sheets |
| S-401 - ENLARGED STRUCTURAL PLANS |
| 443309A - ENGAGEMENT CONTROL STATION04_E-106.pdf |
| Sheets |
| E-106 - GROUNDING AND LIGHTNING PROTECTION PLAN |
| 443309A - ENGAGEMENT CONTROL STATION04_E-107.pdf |
| Sheets |
| E-107 - GROUNDING AND LIGHTNING PROTECTION PLAN " AREA B" |
| 443309A - ENGAGEMENT CONTROL STATION04_E-114.pdf |
| Sheets |
| E-114 - GROUNDING AND LIGHTNING PROTECTION - SITE 7 ALS |
| 443309H - STORAGE FACILITY_E-101.pdf |
| Sheets |
| E-101 - LIGHTING, POWER, GROUNDING AND LIGHTNING PROTECTION PLANS |
| 443309I - FREQUENCY CONV - PDU_E-101.pdf |
| Sheets |
| E-101 - POWER, LIGHTING AND GROUNDING PLAN |
| 443309 - G-012.pdf |
| Sheets |
| G-012 - INDEX OF DRAWINGS VOLUME 2 SHEET 1 |
| 443309 - G-013.pdf |
| Sheets |
| G-013 - INDEX OF DRAWINGS VOLUME 2 SHEET 2 |