AM_6_VOLUME_1_DRAWINGS_19_Aug_16.pdf
PDF 68 KB Posted
- Attached to
- Kuwait Air Defense Improvements Federal contract opportunity
- Solicitation number
- W912ER-16-R-0008
About this file
Volume 1 Drawings
View the file
Other files for this federal contract opportunity
Show all 50
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
B
C
D
2 3 4 5 8/
/2
:3
7:
P M
8/
/2
:3 7:
P
M
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
Enter District
EM
S
G W
D
R O
B
ER
T L.
F O
X , P
E
-G
I0
G N
G-011
JA
R
IN
D
EX
O
F
DR
A W
IN
G
S
VO
LU
M
E
SH
EE
T
P2 -4
G
EN
ER
A
L 1:
INDEX OF DRAWINGS
GENERAL VOLUME 1
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
GENERAL
G-000 450031-GI000GN COVER SHEET VOLUME 1 OF 4
G-004 450031-GI004GN INDEX OF VOLUMES
G-011 443309-GI011GN06 6 AM#6 INDEX OF DRAWINGS VOLUME 1 SHEET 1
G-021 443309-GI021GN STANDARD LEGENDS AND SYMBOLOGY
G-031 443309-GI031GN STANDARD ABBREVIATIONS
443309-SITE DESIGN ICC#3
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
CIVIL
C-001 443309--CS001 OVERALL PROJECTS LOCATION MAP
C-101 443309--CS101PN03 3 AM#3 ICC#3 OVERALL SITE PLAN
C-501 443309--CS501DT03 3 AM#3 CHAIN LINK SECURITY FENCE DETAILS
C-502 443309--CS502DT03 3 AM#3 CHAIN LINK SECURITY FENCE DETAILS
SITE ELECTRICAL
XE-101 443309--XE101PN ELECTRICAL SITE PLAN
SITE TELECOMMUNICATIONS
XT-101 443309--XT101PN TELECOMMUNICATIONS SUNSHADE TO TOWER
XT-102 443309--XT102PN TELECOMMUNICATIONS - RF PATCH PANEL CAOMMAND
POST TO BUILDINGS
XT-103 443309--XT103PN TELECOMMUNICATIONS RF PANEL TO SCREEN ROOM
BUILDING
XT-104 443309--XT104PN TELECOMMUNICATIONS RF PANEL TO ADOC
XT-501 443309--XT501DT TELECOMMUNICATIONS DETAILS
XT-502 443309--XT502DT TELECOMMUNICATIONS DETAILS
XT-503 443309--XT503DT HANDHOLE DETAILS
XT-504 443309--XT504DT DUCTBANK DETAILS
XT-505 443309--XT505DT DUCTBANK DETAILS
XT-506 443309--XT506DT UNDERGROUND CONDUIT TO CABLE TROUGH
CONNECTION
XT-507 443309--XT507DT COMMUNICATION DETAILS
XT-508 443309--XT508DT PATCH PANEL CABLE LADDER DETAIL
XT-509 443309--XT509DT TOWER SITE DETAILS
443309K - SCREEN ROOM BUILDING
SHT. REF.
NO. FILE NO
REVISIONS
TITLEREV. NO. AM/COP NO.
STRUCTURAL
S-101 443309K-SB101PN FOUNDATION AND SLAB PLAN
S-102 443309K-SF102PN ROOF FRAMING PLAN
S-401 443309K-SB401DT NEW AND EXISTING FACILITY INTERFACE DETAILS
S-601 443309K-SF601SC SCHEDULES
ARCHITECTURAL
A-001 443309K-AE001PN LIFE SAFETY PLAN
A-002 443309K-AE002PN AIR BARRIER PLAN
A-100 443309K-AE100PN DEMOLITION PLAN
A-101 443309K-AE101PN06 6 AM#6 GROUND FLOOR PLAN
A-102 443309K-AE102PN ROOF PLAN
A-103 443309K-AE103PN REFLECTED CEILING PLAN
A-201 443309K-AE201EL ELEVATIONS
A-301 443309K-AE301SE BUILDING SECTIONS
A-302 443309K-AE302SE WALL SECTIONS
A-401 443309K-AE401EL SCREEN ROOM
A-501 443309K-AE501DT DETAILS
A-601 443309K-AE601SC06 6 AM#6 DOOR, WINDOW AND FINISH SCHEDULES
MECHANICAL
M-101 443309K-MH101PN GROUND FLOOR HVAC PLAN
M-102 443309K-MH102PN ROOF HVAC PLAN
ELECTRICAL
E-101 443309K-EP101PN POWER AND LIGHTING PLAN
E-102 443309K-EP102PN POWER, GROUNDING AND LIGHTING PROTECTION
PLAN
E-601 443309K-EP601PN PANEL SCHEDULES
E-602 443309K-EP602PN ONE LINE DIAGRAM
TELECOMUNICATIONS
T-101 443309K-TN101PN03 3 AM#3 CABLE TRAY / CONDUIT ENTRANCE PLAN
T-102 443309K-TN102PN03 3 AM#3 TELECOMMUNICATIONS - SCREEN ROOM BUILDING
DETAILS
T-301 443309K-TN301PN03 3 AM#3 CABLE LADDER TO CONDUIT TRANSITION DETAIL
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A M
E N
D M
EN
T
#3
/2 5/
A
M E
N D
M
EN
T #6
/1
8/
A-201
A-201
A-201
A-201
A-301
1 2 3
A
C
SCREEN ROOM
OFFICE AREA
B
400 6800 4200 400 11800
400 6800 4200 400
SEE GEN. NOTE 11
11800
102 EW1
EW1
EW1
A-301
1000 4750 5250
6600 4400
EXPANSION JOINT
AT EXISTING BUILDING
EXPANSION JOINT
AT EXISTING BUILDING
EXISTING BREAK ROOM
OPEN OFFICE
A.1
A.1 1H1H
CONC. COLUMN
W/ PLASTER FIN.
SEPERATE CONC.
LEVELING PAD
EXIST. OPS RM
A-4015
A-401
A-401 2
A-401
ALIGN NEW BUILDING
ADDITION WITH EXIST.
150mm THICK
CONC. PAD
RELOCATED ROOF
SCUPPER LOCATION - VIF
1400 1400 1000 1400 1400
STAINLESS STEEL
COVER PLATE @
EXPANSION JOINT
A-501
A-501
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5 8/
/2
:3
2:
A M
8/
/2
:3 2:
A
M
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
- C O
N
TR
AC
T
N U
M
BE
R
Middle East District
G
AR
Y D
. B A
KE
R
R
.A
R
ST
JE
FF
R E
Y P
. R A
N E
Y C hi ef
, B ld g.
D es ig n S ec tio n
K
-A E
1P
N
A-101
W
IN
C H
E
ST
E R
, V A
JP
R
G R
O
UN
D F
LO
O
R P
LA
N
K
P2 -4
SC
R
E E N
R O
O M
B U
I L D
IN
G
1 : 50A-100
1 FLOOR PLAN
AREA: 127 SQ. METERS
1:50
5m1m 4m3m2m0m
DIM NOTE & NORTH
PLAN NORTH
MECCA
GRAPHIC SCALE
GENERAL NOTES:
1. SYMBOLS AND ABBREVIATIONS SHOWN ON THIS PROJECT ARE
ON G SERIES DRAWINGS.
2. REFER TO CIVIL DRAWING FOR ALL EXTERIOR LEVELS.
3. REFER TO ELECTRICAL DRAWINGS FOR LIGHTENING
PROTECTION DESIGN AND DETAILS.
4. ALL DOORS TO BE LOCATED 200MM FROM THE NEAREST
INTERSECTING WALL U.N.O.
5. ALL FLOOR MOUNTED EQUIPMENT SHALL HAVE 150MM HOUSE
KEEPING PADS. COORDINATE WITH SELECTED EQUIPMENT FOR
SIZE.
6. ALL DIMENSIONS ARE TO FACE OF CONCRETE OR MASONRY,
CENTERLINE OF COLUMNS.
7. MASONRY AND CONCRETE CONSTRUCTION JOINTS OCCUR AT
EVERY COLUMN AND PERPENDICULAR WALL INTERSECTIONS
U.N.O.
8. REFER TO SHEET SA-501 FOR EXTERIOR WALL TYPES.
9. REFER TO SHEET SA-502 FOR INTERIOR WALL TYPES.
10. REFER TO SHEET A-601 FOR DOOR AND FINISH SCHEDULES
11. ALIGN NEW BUILDING ADDITION 150mm FROM EXISTING ROOF
SCUPPER. VERIFY IN FIELD.
12. ANY FURNITURE SHOWN IS FOR INFORMATION ONLY. (NIC)
GROSS BUILDING AREA
GROUND FLOOR: 127 SM
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A M
E N
D M
EN
T
#6
/1 8/
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
S U
BM
IT
T E D
B Y:
S
IZ
E:
FI
LE
N
O
IS
SU
E D
A T E:
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C
KD
B Y:
US Army Corps of Engineers ®
X
A
P
LO
T
SC
AL
E:
P
LO
T D
A T E:
US
A rm y
Co rp s of
E ng in ee rs M id dl e Ea st D is tri ct
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
B
C
D
2 3 4 5 8/
/2
:3
2:
A M
8/
/2
:3 2:
A
M
U N
SP
E C
IF
IE
D W
O R
L D W
ID
E
A
IR
D
EF
EN
SE
IM
PR
O V E
M
EN
TS
-0 7-
- C O
N
TR
AC
T
N U
M
BE
R
Middle East District
G
AR
Y D
. B A
KE
R
R
.A
R
ST
JE
FF
R E
Y P
. R A
N E
Y C hi ef
, B ld g.
D es ig n S ec tio n
K
-A E
1S
C
A-601
W
IN
C H
E
ST
E R
, V A
JP
R
D O
O R, W
IN
DO
W
A N
D F
IN
IS
H S
CH
ED
U
LE
S
K
P2 -4
SC
R
E E N
R O
O M
B U
I L D
IN
G
DOOR SCHEDULE
Door Number Type
DOOR
Fire
Rating
FRAME
Hardware Comments
SIZE
Material Finish Type Material Finish
DETAILS
Width Height Thickness Head Jamb SILL 101 DF 1850 2150 50 WD STAIN 1HR F2 HM PTD 7/SA-508 8/SA-508 9/SA-508 30 ASTRAGAL
102 DF 1800 2150 50 HMD PTD F2 HM PTD 1/SA-508 2/SA-508 3/SA-508 4
103 MFG. 900 2150 50 BY OTHER - SCREEN ROOM MANUF.
104 A 900 2150 50 WD STAIN F1 HM PTD 7/SA-508 8/SA-508 9/SA-508 21
FINISH SCHEDULE
ROOM
NO
ROOM
NAME Area
WALL FINISH Base Finish
FLOOR
CEILIN
G
NOTES & REMARKSNORTH EAST SOUTH WEST FIN. FIN.
101 SCREEN ROOM 14.67 m² FINISHES PER MANUFACTURER 102 OFFICE AREA 16.46 m² PLASTER PLASTER PLASTER PLASTER 200MM TILE TERR. TILE ACT 103 OPEN OFFICE 78.45 m² PLASTER PLASTER PLASTER PLASTER 200MM TILE TERR. TILE ACT
WINDOW SCHEDULE
WT Mark R.O.
Description FRAME GLAZING DETAILS Remarks (See Notes
Below)Width Height Finish Material Type Head Jamb Sill
2 1H 600 2032 SIDELIGHT PTD HM SAFETY LAM 7/SA-507 8/SA-507 9/SA-507
FINISH LEGEND:
ACT - ACOUSTIC CEILING TILE
FINISH NOTES:
1. TILE ASSEMBLIES SHALL HAVE A CONT. 150MM HIGH COVE BASE.
2. A.C.T. SHALL BE 600 X 600 X 19MM FINE TEXTURED, MOISTURE RESISTANT WITH AN ANGLED TEGULAR EDGE. CLASS A, FIRE RETARDANT RATED PANEL AND A INTERMEDIATE DUTY, SEISMIC RATED, PRE-FINISHED ALUMINUM SUSPENSION SYSTEM WITH A 600 X 600MM GRID AND A 25MM WIDE EXPOSED EDGE.
PANELS, DIFFUSER GRILLS, LOUVERS AND GRID COLOR SHALL BE WHITE.
3. PLASTER SHALL BE A TRANDITIONALLY APPLIED WITH A TWO TO THREE COAT SYSTEM. SMOOTH FINISH TO MATCH EXISTING AND PAINT. COLOR SHALL BE
SELECTED BY COR.
DOOR NOTES:
1. SEE SHEET SA-506 FOR DOOR TYPES
WINDOW NOTES:
1. SEE SHEET SA-506 FOR WINDOW TYPES.
M
AR
K D
ES
C
R
IP
TI
O
N D
A
TE
A P
PR
A M
E N
D M
EN
T
#6
/1 8/
| Sheets |
| G-011 - INDEX OF DRAWINGS VOLUME 1 SHEET 1 |
| 443309K - SCREEN ROOM BUILDING06.pdf |
| Sheets |
| A-101 - GROUND FLOOR PLAN |
| A-601 - DOOR, WINDOW AND FINISH SCHEDULES |
File details come from the government source that posted it. Updated .