AM_3_VOLUME_1_DRAWING.pdf

PDF 967 KB Posted

Attached to
Kuwait Air Defense Improvements Federal contract opportunity
Solicitation number
W912ER-16-R-0008
Issued by
Department of the Army Corps of Engineers Engineering District Middle East

About this file

Volume 1 Drawing Changes

View the file

Other files for this federal contract opportunity

Other files attached to Kuwait Air Defense Improvements, newest first.
File Type Posted
AM_8_VOLUME_3_DRAWING_.pdf PDF
W912ER-16-R-0008-0008.pdf PDF
Exhibit_1.pdf PDF
AM_8_Specifications_ _Attachment.pdf PDF
AM_8_VOLUME_2_DRAWING.pdf PDF
W912ER-16-R-0008-0007.pdf PDF
AM_7_Proposal_Schedule_.pdf PDF
ATTACHMENT_3_Relevancy_Matrix.pdf PDF
AM_6_VOLUME_4_DRAWINGS_19_Aug_16.pdf PDF
W912ER-16-R-0008-0006.pdf PDF
AM_6_Cost_Breakdown_19_Aug_16.pdf PDF
AM_6_VOLUME_3_DRAWINGS_19_Aug_16.pdf PDF
AM_6_Specifications_19_Aug_16.pdf PDF
AM_6_VOLUME_2_DRAWINGS_19_Aug_16.pdf PDF
AM_6_VOLUME_1_DRAWINGS_19_Aug_16.pdf PDF
W912ER-16-R-0008-0005.pdf PDF
AM_4_Proposal_Schedule_.pdf PDF
Exhibit_1.pdf PDF
AM_4_Specifications.pdf PDF
AM_4_VOLUME_3_DRAWING.pdf PDF
W912ER-16-R-0008-0004.pdf PDF
AM_4_Cost_Breakdown.pdf PDF
AM_4_VOLUME_2_DRAWING.pdf PDF
AM_3_VOLUME_4_DRAWING.pdf PDF
W912ER-16-R-0008-0003.pdf PDF
AM_3_VOLUME_3_DRAWING.pdf PDF
AM_3_VOLUME_2_DRAWING.pdf PDF
Exhibit_1.pdf PDF
AM_3_Specifications_28_Jul_16.pdf PDF
W912ER-16-R-0008-0002.pdf PDF
Attachment_2_Prime_Construction_Experience_Form.pdf PDF
Attachment_1_Experience_Overview_Sheet.pdf PDF
Amendment_W912ER-16-R-0008-0001.pdf PDF
Attachment_3_Relevancy_Matrix.pdf PDF
Appendix_D_Attachment.pdf PDF
Volume_4_Drawings.pdf PDF
Volume_2_Specifications.pdf PDF
Volume_2_Drawings.pdf PDF
Volume_1_Drawings.pdf PDF
Volume_1_Specifications.pdf PDF
Proposal_Schedule.pdf PDF
Volume_3_Specifications.pdf PDF
W912ER-16-R-0008.pdf PDF
Volume_3_Drawings.pdf PDF
DRAFT_CDC_Vol_3_of_3_11-Jan-15.pdf PDF
DRAFT_443309_-_VOLUME_1_03-31-16.pdf PDF
DRAFT_443309_-_VOLUME_2_03-31-16.pdf PDF
DRAFT_443309_-_VOLUME_3_03-31-16.pdf PDF
DRAFT_CDC_Vol_2_of_3_11-Jan-15.pdf PDF
DRAFT_443309_-_VOLUME_4_03-31-16.pdf PDF
Show all 50

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

S U

BM

IT

T E D

B Y:

S

IZ

E:

FI

LE

N

O

IS

SU

E D

A T E:

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

C

KD

B Y:

US Army Corps of Engineers ®

X

A

P

LO

T

SC

AL

E:

P

LO

T D

A T E:

US

A rm y

Co rp s of

E ng in ee rs M id dl e Ea st D is tri ct M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

B

C

D

2 3 4 5 7/

/2

:4

4:

P M

7/

/2

:4 4:

P

M

U N

SP

E C

IF

IE

D W

O R

L D W

ID

E

A

IR

D

EF

EN

SE

IM

PR

O V E

M

EN

TS

-0 7-

Enter District

EM

S

G W

D

R O

B

ER

T L.

F O

X , P

E

-G

I0

G N

G-011

JA

R

IN

D

EX

O

F

DR

A W

IN

G

S

VO

LU

M

E

SH

EE

T

P2 -4

G

EN

ER

A

L 1:

INDEX OF DRAWINGS

GENERAL VOLUME 1

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

GENERAL

G-000 450031-GI000GN COVER SHEET VOLUME 1 OF 4

G-004 450031-GI004GN INDEX OF VOLUMES

G-011 443309-GI011GN03 3 AM#3 INDEX OF DRAWINGS VOLUME 1 SHEET 1

G-021 443309-GI021GN STANDARD LEGENDS AND SYMBOLOGY

G-031 443309-GI031GN STANDARD ABBREVIATIONS

443309-SITE DESIGN ICC#3

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

CIVIL

C-001 443309--CS001 OVERALL PROJECTS LOCATION MAP

C-101 443309--CS101PN03 3 AM#3 ICC#3 OVERALL SITE PLAN

C-501 443309--CS501DT03 3 AM#3 CHAIN LINK SECURITY FENCE DETAILS

C-502 443309--CS502DT03 3 AM#3 CHAIN LINK SECURITY FENCE DETAILS

SITE ELECTRICAL

XE-101 443309--XE101PN ELECTRICAL SITE PLAN

SITE TELECOMMUNICATIONS

XT-101 443309--XT101PN TELECOMMUNICATIONS SUNSHADE TO TOWER

XT-102 443309--XT102PN TELECOMMUNICATIONS - RF PATCH PANEL CAOMMAND

POST TO BUILDINGS

XT-103 443309--XT103PN TELECOMMUNICATIONS RF PANEL TO SCREEN ROOM

BUILDING

XT-104 443309--XT104PN TELECOMMUNICATIONS RF PANEL TO ADOC

XT-501 443309--XT501DT TELECOMMUNICATIONS DETAILS

XT-502 443309--XT502DT TELECOMMUNICATIONS DETAILS

XT-503 443309--XT503DT HANDHOLE DETAILS

XT-504 443309--XT504DT DUCTBANK DETAILS

XT-505 443309--XT505DT DUCTBANK DETAILS

XT-506 443309--XT506DT UNDERGROUND CONDUIT TO CABLE TROUGH

CONNECTION

XT-507 443309--XT507DT COMMUNICATION DETAILS

XT-508 443309--XT508DT PATCH PANEL CABLE LADDER DETAIL

XT-509 443309--XT509DT TOWER SITE DETAILS

443309K - SCREEN ROOM BUILDING

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

STRUCTURAL

S-101 443309K-SB101PN FOUNDATION AND SLAB PLAN

S-102 443309K-SF102PN ROOF FRAMING PLAN

S-401 443309K-SB401DT NEW AND EXISTING FACILITY INTERFACE DETAILS

S-601 443309K-SF601SC SCHEDULES

ARCHITECTURAL

A-001 443309K-AE001PN LIFE SAFETY PLAN

A-002 443309K-AE002PN AIR BARRIER PLAN

A-100 443309K-AE100PN DEMOLITION PLAN

A-101 443309K-AE101PN GROUND FLOOR PLAN

A-102 443309K-AE102PN ROOF PLAN

A-103 443309K-AE103PN REFLECTED CEILING PLAN

A-201 443309K-AE201EL ELEVATIONS

A-301 443309K-AE301SE BUILDING SECTIONS

A-302 443309K-AE302SE WALL SECTIONS

A-401 443309K-AE401EL SCREEN ROOM

A-501 443309K-AE501DT DETAILS

A-601 443309K-AE601SC DOOR, WINDOW AND FINISH SCHEDULES

MECHANICAL

M-101 443309K-MH101PN GROUND FLOOR HVAC PLAN

M-102 443309K-MH102PN ROOF HVAC PLAN

ELECTRICAL

E-101 443309K-EP101PN POWER AND LIGHTING PLAN

E-102 443309K-EP102PN POWER, GROUNDING AND LIGHTING PROTECTION

PLAN

E-601 443309K-EP601PN PANEL SCHEDULES

E-602 443309K-EP602PN ONE LINE DIAGRAM

TELECOMUNICATIONS

T-101 443309K-TN101PN03 3 AM#3 CABLE TRAY / CONDUIT ENTRANCE PLAN

T-102 443309K-TN102PN03 3 AM#3 TELECOMMUNICATIONS - SCREEN ROOM BUILDING

DETAILS

T-301 443309K-TN301PN03 3 AM#3 CABLE LADDER TO CONDUIT TRANSITION DETAIL

M

AR

K D

ES

C

R

IP

TI

O

N D

A

TE

A P

PR

A M

E N

D M

EN

T

#3

/2 5/

X

X

HANDHOLE

EXISTING

BOX

GROUND

EXISTING

AREA

ACCESS AND LAYDOWN

CONSTRUCTION

TEMPORARY

EXISTING COMM. TOWER

EXISTING GATE

EXISTING SUNSHADE

EXISTING GATE

EXISTING COMMAND POST

SIDEWALK

BE MOVED BY OTHERS

EXISTING TRAILER TO

EXISTING JUNCTION BOX

CONVERTER BUILDING

EXISTING FREQUENCY

EXISTING OFFICE TRAILER

SUNSHADES (TO REMAIN)

EXISTING PARKING

FOR GENERATORS

EXISTING SUNSHADE

ICC#3 TO BE PLACED HERE BY OTHERS

EXISTING ICC#1,

ADDITION

BUILDING

ROOM

SCREEN

NEW FENCING

X

(APPROX. 19m)

TO BE REMOVED

EXISTING FENCE

PORTION OF

XX

XX X X

X

.8

18.48

SHEET ID

-0

-0

C-101

T S

R

A J F

G L

H

X

Middle East District of Engineers

US Army Corps

U S A rm y C o rp s o f

E n g in e e rs

M id d le E a s t

D is tr ic t

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

D A

T E

A P

P R

GRAPHIC SCALE

DIM. NOTE & NORTH

GENERAL SHEET NOTES

SHEET KEYNOTES

N

DIMENSIONS SHOWN ARE IN METERS.

UNLESS OTHERWISE NOTED, LINEAR

n e n s a jf

IP

P W

P d

C S P

N .d g n

S

IT

E I

C C

-0

-1

C h ie f, C iv il B ra n c h

P -4

1:250

10 5 10 150

1:250

10 5 10 15

A

IR

D

E F

E N

S E I

M P

R O

V E

M E

N T S

U N

S P

E C

IF

IE

D W

O R

L D

W

ID

E

EXISTING FENCE

SCALE= 1:250

OVERALL SITE PLAN

G L E

N N L

H O

R D

U S

K Y

S

IT

E I

C C

O

V E

R A

L L S

IT

E P

L A

N

EXISTING FENCE

BUILDING

MAINT.

EXISTING

MATCH EXISTING FENCING TYPE/HEIGHT/ETC.

FENCE IN ORDER TO MAINTAIN FENCE BOUNDARY AND TO

1. NEW FENCING TO REPLACE REMOVED PORTION OF EXISTING

C S P

N

/2

/2

C L

A R

IF

IC

A T

IO

N

A M

E X

A N

D N

E W F

E N

C E

LINE POST ATTACHMENTS

LINE POST CORNER POST

ROUND POST

XXXXX

X

X

X

X

X

X

X

X

X

X

XXXXX

X

X

X

X

X

X

X

X

X

X

XXXXX

X X X X X

XXXXX

XXX

X

X

X X X

XXXX

XXXX

X X X X

XXXX

XXXXX

X X X X X

XXXXX

XXXX

X X

XXX

X

END OR GATE POST DETAIL

BRACE RAIL CLAMP DETAILS

TENSION BAND DETAIL

TOP OR BRACE RAIL ATTACHMENT

3000 MAX3000 MAX

CORNER OR END BRACE PANEL LINE POST TO BE EQUALLY SPACED

LINE POST

10 RIVET

riveted flush (typ.)

10 plain pin

LOCK PIN

TENSION WIRE

TENSION BAR

CARRIAGE BOLT

FABRIC

TENSION BAND

USE

MINIMUM OUTSIDE DIMENSIONS (NOMINAL)

CORNER, END & PULL POSTS

LINE POSTS

TOP, BOTTOM & BRACE RAILS

73 O.D.

100 O.D.

42 O.D.

TRUSS ROD

X

DOUBLE RAIL END

LINE POST

FABRIC

BOTTOM RAIL

LOCK PIN

SECURE SIDE

CONCRETE BASE

TRUSS ROD

TENSION WIRE

BRACE RAILS

LINE POST

TIE WIRES

TRUSS ROD

BOTTOM RAIL

FINISH GRADE

CONCRETE TYP

TENSION BAR TO ENGAGE

EACH FABRIC LINK

TENSION BAND

380 OC MAX

100 FROM TOP AND BOTTOM

10 CARRAGE BOLT

WITH PEENED THREADS

9 GAGE STEEL TIE WIRE

600 OC MAX

9 GAGE STEEL TIE WIRES

600 IC MAX

9 GAGE STEEL TIE WIRE

381 OC MAX

100 FROM TOP AND BOTTOM

CHAIN LINK FABRIC

9 GAGE MINIMUM

NOT TO SCALE

CHAIN-LINK SECURITY FENCE DETAIL

NOT TO SCALE

TRUSS ROD AND BAND

NOT TO SCALE

EXTENSION ARM DETAILS

NOT TO SCALE

BOTTOM RAIL DETAILS

NOT TO SCALE

FASTENING DETAILS

TENSION WIRE

END POST

CORNER OR

CONCRETE FILLED

6 STRANDS OF BARBED-WIRE

LINE POST LINE POST

TRUSS ROD TRUSS ROD

NOTE:

TOP TENSION WIRE

STRAIGHT RUNS EXCEED 500 FEET.

PROVIDE BRACE PANEL WHENEVER

RAILS

BRACE

RAILS

BRACE

RAIL

BOTTOM

NOT TO SCALE

BRACE PANEL DETAIL

3000 MAX. 3000 MAX.

PULL POST

FILLED

CONCRETE

X

X

X

X

X

XX

X

X

X

X

XXXXX

X

X

X

X

X X

XX

XXXXX

X X X X

XXXX

X

X

XXXX

X X X X

XXXX

X

X

XX

X

X

BOLTS PASS THROUGH THE BOTTOM RAIL AS SHOWN.

DRILLED THROUGH THE BOTTOM RAIL ENDS TO INSURE THAT CARRIAGE

10MM CARRIAGE BOLTS AS SHOWN. ADDITIONAL HOLES SHALL BE

3. BOTTOM RAIL SHALL BE ATTACHED TO DOUBLE RAIL ENDS USING

SHALL NOT BE ALLOWED.

FOR FASTENING FENCE FABRIC TO TENSION WIRES. HOG RINGS

16-GAGE, STAINLESS STEEL TIE WIRES SHALL BE USED

FOR FASTENING THE FENCE FABRIC TO FENCE POSTS AND RAILS.

2. ONLY 9-GAGE GALVANIZED STEEL TIE WIRES SHALL BE USED

FABRIC SHALL BE PLACED ON THE SIDE OPPOSITE THE SECURE AREA.

ON THE SECURE SIDE OF THE FENCE ALIGNMENT. CHAIN-LINK

1. WIRE TIES, RAILS, POSTS, AND BRACES SHALL BE CONSTRUCTED

NOTES:

SHEET ID

-0

-2

C-501

A J F

A J F

G L

H

X

DIMENSIONS SHOWN ARE IN MILLIMETERS.

UNLESS OTHERWISE NOTED, LINEAR

Middle East District of Engineers

US Army Corps

U S A rm y C o rp s o f

E n g in e e rs

M id d le E a s t

D is tr ic t

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

D A

T E

A P

P R n e n s a jf

IP

P W

P d

C S

D T .d g n

-0

-4

U N

S P

E C

IF

IE

D W

O R

L D

W

ID

E

C H

A

IN

L

IN

K S

E C

U R

IT

Y F

E N

C E D

E T

A

IL

S

A

IR

D

E F

E N

S E I

M P

R O

V E

M E

N T S

J E

F F

R E

Y P

R A

N E

Y

C h ie f, A rc h it e c t

B ra n c h

S

IT

E I

C C

A

M

IS

S U

E D E

N T

IR

E S

H E

E T

/2

/2

C S -D

T

NOT TO SCALE

1.70 in.

.2 m m

.2 i n

.7 i n

.7 i n

1.70 in.

0.12 in.

FENCE PIPE

END POST

CORNER POST

BRACE POST

LINE POST

TOP RAIL

TRUSS BRACE

D

73.0 mm (2.875 in.)

73.0 mm (2.875 in.)

73.0 mm (2.875 in.)

60.3 mm (2.375 in.)

41.3 mm (1.625 in.)

41.3 mm (1.625 in.)

8.62 (5.79)

8.62 (5.79)

8.62 (5.79)

5.43 (3.65)

3.38 (2.27)

3.38 (2.27) kg/m (#/ft.) GATE POSTS

1.83-3.66 m SWING

D

101.6 mm (4in.) 13.56 (9.11) kg/m (#/ft.)

4.05 (2.72)GATE FRAME 50.8 mm (2in.)

4 OPTION 48.3 mm (1.900 in.) DIA WITH MIN. WALL THICKNESS OF 3.0 mm (0.120 in.).

3 IF REQUIRED. OPTION 42.2 mm (1.660 in.) DIA WITH MIN WALL THICKNESS OF 2.8 mm (0.111 in.).

2 ABOVE OPTION OR 60.3 mm(2.375 in.) DIA WITH MIN. WALL THICKNESS OF 3.3 mm (0.13 in.).

1 OPTION 71.8 mm (2.825 in.) DIA WITH MIN. WALL THICKNESS OF 4.1 mm (0.160 in.)

FINISH TOP AND BOTTOM

TWISTED AND BARBED

43.2 mm

.2 i n

D

43.2 mm

.1 m m .1 m m

.2 m m

3.1 mm

CHAIN LINK DETAIL

FENCE POST

FITTING OF COPPER

OR APPROVED CLAMP-TYPE

MOLDED EXOTHERMIC WELD

COPPER WIRE

#8 AWG SOLID

NOT TO SCALE

GROUNDING DETAIL

ROD

STEEL GROUND

COPPER-CLAD

19 DIA.

SHEET ID

-0

-2

C-502

A J F

A J F

G L

H

X

DIMENSIONS SHOWN ARE IN MILLIMETERS.

UNLESS OTHERWISE NOTED, LINEAR

Middle East District of Engineers

US Army Corps

U S A rm y C o rp s o f

E n g in e e rs

M id d le E a s t

D is tr ic t

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

D A

T E

A P

P R n e n s a jf

IP

P W

P d

C S

D T .d g n

-0

-4

U N

S P

E C

IF

IE

D W

O R

L D

W

ID

E

A

IR

D

E F

E N

S E I

M P

R O

V E

M E

N T S

J E

F F

R E

Y P

R A

N E

Y

C H

A

IN

L

IN

K S

E C

U R

IT

Y F

E N

C E D

E T

A

IL

S

C h ie f, A rc h it e c t

B ra n c h

C S -D

T

S

IT

E I

C C

A

M

IS

S U

E D E

N T

IR

E S

H E

E T

/2

/2

PROPOSED POINT OF

PRESENCE EQUIPMENT RACK

2-114mm OD PVC

CONDUITS STUBBED

1M FROM WALL

FUTURE

CABINETS

RAYTHEON

CABINETS (BLACK)

TERMINATOR PANELS

LOCATION RAYTHEON

TO INSTALL TERMINATOR

PANEL

TERMINATOR PANELS

LOCATION RAYTHEON

TO INSTALL TERMINATOR

PANEL

150mm WIDE x 76mm HIGH

CABLE TRAY MOUNTED

2827 AFF

450mm WIDE x 152mm HIGH

CABLE TRAY MOUNTED

2287 AFF

103mm ID CONDUITS

T-102

A

T-102

B

T-102 C

T-102

D

T-102

E

T-102F

T-102

H

TWO (2) 114mm OD STEEL CONDUITS w/

PLASTIC BUSHINGS

ON BOTH ENDS

150mm WIDE x 76mm HIGH

CABLE TRAY MOUNTED

2827 AFF

CONTRACTOR TO INSTALL 6 - 119mm SQUARE x 54mm SURFACE-MOUNTED

DEEP STEEL BOXES AND CONNECT THOSE BOXES TO THE CABLE TRAY

VIA 25mm STEEL CONDUIT. ADD PULL TAPE TO CONDUIT AND TIE OFF 1M

AT BOTH ENDS.

PROVIDE RUBBER

CAPS ON ALL EXPOSED

CABLE LADDER ENDS

152mm GAP

PROVIDE CABLE

DROP-OUTS

(PLUS 2 EXTRA)

T-301

T-301

CONDUIT ENTRANCE FROM POP

(POINT OF PRESENCE)

119mm SQUARE X 54mm DEEP

STEEL SURFACE-MOUNT BOXES

CONNECTED TO CABLE LADDER

VIA 25mm STEEL COUNDUIT.

119mm SQUARE X 54mm DEEP

STEEL SURFACE-MOUNT BOXES

CONNECTED TO CABLE LADDER

VIA 25mm STEEL COUNDUIT.

NOTE1: INSTALL GROUND BAR (TGB) 152mm BELOW THE SCREEN ROOM

PENETRATION PLATE. CONNECT TO BUILDING GROUND BAR IN ELEC PANEL

CP1 VIA GROUND CABLE SIZED IAW ANSI EIA/TIA 607. INSTALL A 16mm2 COPPER CONDUCTOR FROM THE TGB TOA A LOCATION 152mm BELOW EACH

OF THE FOUR (4) ROOM PENETRATION PLATE[S]. TERMINATE CABLE IN A

ONE-HOLE LUG BOLTED TO THE TOP OF AN INSULATOR.

NOTE 1

NOTE 2: INSTALL GROUND BAR[S] ON BOTH SECTIONS OF THE CABLE

LADDER SYSTEM IN SCREEN ROOM 101. CONNECT THE CABLE LADDER

GROUND BAR TO THE WALL MOUNTED GROUND BAR (TGB) IN THE

SCREEN ROOM.

TELECOMMUNICAITON MAIN GROUNDING BUSBAR (TMGB)

PLACED AT 2000mm AFF CONNECTED TO ELECTRICAL

SERVICE ENTRANCE GROUND IN CP1. CABLE TRAY SYSTEM

SHALL BE CONNECTED TO THE TMGB.

TGB:

NOTE 2

NOTE 2

NOTE 2

NOTE 3: ALL CABLE TRAYS IN THE SCREEN ROOM BUILDING SHALL BE OF

CABLE LADDER TYPE.

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

S U

BM

IT

T E D

B Y:

S

IZ

E:

FI

LE

N

O

IS

SU

E D

A T E:

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C

KD

B Y:

US Army Corps of Engineers ®

X

A

P

LO

T

SC

AL

E:

P

LO

T D

A T E:

US

A rm y

Co rp s of

E ng in ee rs M id dl e Ea st D is tri ct

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

B

C

D

2 3 4 5 7/

/2

5:

:4

A M

7/

/2

5:

:4

AM

U N

SP

E C

IF

IE

D W

O R

L D W

ID

E

A

IR

D

EF

EN

SE

IM

PR

O V E

M

EN

TS

-0 7-

- C O

N

TR

AC

T

N U

M

BE

R

Middle East District

C H

D I

D

AV

E S

. C

LA

R

KE

K

-T N

1P

N

T-101

W

IN

C H

E

ST

E R

, V A

D I

C A

BL

E

TR

AY

C

O N

D

UI

T

EN

T R

AN

C E

PL

A

N

K

P2 -4

SC

R

E E N

R O

O M

B U

I L D

IN

G

1 : 30

COMMUNICATION PLAN - CABLE TRAY/CONDUIT ENTRANCE PLAN

K

ENTRANCE CONDUITS (10)

M

AR

K D

ES

C

R

IP

TI

O

N D

A

TE

A P

PR

A M

E N

D M

EN

T

#3

/2 5/

1:30

3m0.6m 2.4m1.8m1.2m0m

FIN. FLOOR

FIN. FLOOR

T-301

FIN. FLOOR

A

T-301

FIN. FLOOR

T-301

FIN. FLOOR

TOF

-1075

114mm OD CONDUIT

114mm OD CONDUIT BENDING RADIUS 914mm

PULLBOX 762mm HIGH x 508mm WIDE x 305mm DEEP

FIN. FLOOR

A

FIN. FLOOR

T-301

NOTE: TRANSITION FROM

2286mm (7.5') TO 2825mm (9.27')

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

S U

BM

IT

T E D

B Y:

S

IZ

E:

FI

LE

N

O

IS

SU

E D

A T E:

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C

KD

B Y:

US Army Corps of Engineers ®

X

A

P

LO

T

SC

AL

E:

P

LO

T D

A T E:

US

A rm y

Co rp s of

E ng in ee rs M id dl e Ea st D is tri ct

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

B

C

D

2 3 4 5 7/

/2

7:

:0

A M

7/

/2

7:

:0

AM

U N

SP

E C

IF

IE

D W

O R

L D W

ID

E

A

IR

D

EF

EN

SE

IM

PR

O V E

M

EN

TS

-0 7-

- C O

N

TR

AC

T

N U

M

BE

R

Middle East District

C H

D I

D

AV

E S

. C

LA

R

KE

K

-T N

2P

N

T-102

W

IN

C H

E

ST

E R

, V A

D I

TE

LE

C O

M M

U N

IC

A

T I O

N S

- S

CR

EE

N

R O

O M

B U

IL

D

IN

G

D

ET

A

IL

S

K

P2 -4

SC

R

E E N

R O

O M

B U

I L D

IN

G

1 : 30T-101

A SCREEN ROOM PENETRATION PANEL

1 : 30T-101

B CABINET CABLE LADDER

1 : 30T-101

C CABLE ENTRY DIAGRAM

1 : 30T-101

D SCREEN ROOM PENETRATION PANEL 2

1 : 30T-101

E SCREEN BUILDING CABLE TRAY

1 : 30T-101

F SCREEN ROOM SPARE

1 : 30T-101

H POP TRANSITION TO SCREEN ROOM TERMINATOR PANEL (RED SYSYTEM)

M

AR

K D

ES

C

R

IP

TI

O

N D

A

TE

A P

PR

A M

E N

D M

EN

T

#3

/2 5/

1:30

3m0.6m 2.4m1.8m1.2m0m

FIN. FLOOR

FIN. FLOOR

A

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

S U

BM

IT

T E D

B Y:

S

IZ

E:

FI

LE

N

O

IS

SU

E D

A T E:

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C

KD

B Y:

US Army Corps of Engineers ®

X

A

P

LO

T

SC

AL

E:

P

LO

T D

A T E:

US

A rm y

Co rp s of

E ng in ee rs M id dl e Ea st D is tri ct

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

B

C

D

2 3 4 5 7/

/2

7:

:1

A M

7/

/2

7:

:1

AM

U N

SP

E C

IF

IE

D W

O R

L D W

ID

E

A

IR

D

EF

EN

SE

IM

PR

O V E

M

EN

TS

-0 7-

- C O

N

TR

AC

T

N U

M

BE

R

Middle East District

C H

D I

D

AV

E S

. C

LA

R

KE

K

-T N

1P

N

T-301

W

IN

C H

E

ST

E R

, V A

D I

C A

B L E

LA

D

D

ER

T O

C O

N D

U

IT

T R

A

NS

IT

IO

N D

ET

A

IL

K

P2 -4

SC

R

E E N

R O

O M

B U

I L D

IN

G

1 : 10T-101

1 CABLE LADDER TO CONDUIT TRANSITION DETAIL - SIDE VIEW

1 : 10T-101

2 CABLE LADDER DROPOUT DETAIL - WALL VIEW

PROVIDE CABLE DROPOUTS (WATERFALLS) IN THE TRANSITION

FROM THE HORIZONTAL CABLE LADDER TO THE VERTICAL WALL

MOUNTED CABLE LADDER.

M

AR

K D

ES

C

R

IP

TI

O

N D

A

TE

A P

PR

A M

E N

D M

EN

T

#3

/2 5/

1:10

1m0.2m 0.8m0.6m0.4m0m

Sheets
G-011 - INDEX OF DRAWINGS VOLUME 1 SHEET 1
443309--CS101PN03.pdf
443309--CS101PN03
References
443309--CS101PN03.dgn, Model
PW_WORKDIR:dms48248
2012_drawing template.dgn
443309--CS501-DT03.pdf
443309--CS501-DT03
References
443309--CS501-DT03.dgn, Model
443309--CS502-DT03.pdf
443309--CS502-DT03
References
443309--CS502-DT03.dgn, Model
443309K-T10103_n0enedbi.pdf
Sheets
T-101 - CABLE TRAY / CONDUIT ENTRANCE PLAN
443309K-T10203_n0enedbi.pdf
Sheets
T-102 - TELECOMMUNICATIONS - SCREEN ROOM BUILDING DETAILS
443309K-T30103_n0enedbi.pdf
Sheets
T-301 - CABLE LADDER TO CONDUIT TRANSITION DETAIL
443309K - t-102, t-301.pdf
Sheets
T-102 - TELECOMMUNICATIONS - SCREEN ROOM BUILDING DETAILS
T-301 - CABLE LADDER TO CONDUIT TRANSITION DETAIL