AM_6_VOLUME_2_DRAWINGS_19_Aug_16.pdf

PDF 1 MB Posted

Attached to
Kuwait Air Defense Improvements Federal contract opportunity
Solicitation number
W912ER-16-R-0008
Issued by
Department of the Army Corps of Engineers Engineering District Middle East

About this file

Volume 2 Drawings

View the file

Other files for this federal contract opportunity

Other files attached to Kuwait Air Defense Improvements, newest first.
File Type Posted
Exhibit_1.pdf PDF
AM_8_VOLUME_3_DRAWING_.pdf PDF
W912ER-16-R-0008-0008.pdf PDF
AM_8_Specifications_ _Attachment.pdf PDF
AM_8_VOLUME_2_DRAWING.pdf PDF
W912ER-16-R-0008-0007.pdf PDF
AM_7_Proposal_Schedule_.pdf PDF
ATTACHMENT_3_Relevancy_Matrix.pdf PDF
AM_6_Specifications_19_Aug_16.pdf PDF
AM_6_VOLUME_4_DRAWINGS_19_Aug_16.pdf PDF
W912ER-16-R-0008-0006.pdf PDF
AM_6_Cost_Breakdown_19_Aug_16.pdf PDF
AM_6_VOLUME_3_DRAWINGS_19_Aug_16.pdf PDF
AM_6_VOLUME_1_DRAWINGS_19_Aug_16.pdf PDF
W912ER-16-R-0008-0005.pdf PDF
AM_4_Proposal_Schedule_.pdf PDF
Exhibit_1.pdf PDF
AM_4_Specifications.pdf PDF
AM_4_VOLUME_3_DRAWING.pdf PDF
W912ER-16-R-0008-0004.pdf PDF
AM_4_Cost_Breakdown.pdf PDF
AM_4_VOLUME_2_DRAWING.pdf PDF
AM_3_VOLUME_1_DRAWING.pdf PDF
AM_3_VOLUME_4_DRAWING.pdf PDF
W912ER-16-R-0008-0003.pdf PDF
AM_3_VOLUME_3_DRAWING.pdf PDF
AM_3_VOLUME_2_DRAWING.pdf PDF
Exhibit_1.pdf PDF
AM_3_Specifications_28_Jul_16.pdf PDF
W912ER-16-R-0008-0002.pdf PDF
Attachment_2_Prime_Construction_Experience_Form.pdf PDF
Attachment_1_Experience_Overview_Sheet.pdf PDF
Amendment_W912ER-16-R-0008-0001.pdf PDF
Attachment_3_Relevancy_Matrix.pdf PDF
Appendix_D_Attachment.pdf PDF
Volume_1_Specifications.pdf PDF
Proposal_Schedule.pdf PDF
Volume_3_Specifications.pdf PDF
W912ER-16-R-0008.pdf PDF
Volume_4_Drawings.pdf PDF
Volume_2_Specifications.pdf PDF
Volume_2_Drawings.pdf PDF
Volume_1_Drawings.pdf PDF
Volume_3_Drawings.pdf PDF
DRAFT_443309_-_VOLUME_3_03-31-16.pdf PDF
DRAFT_CDC_Vol_2_of_3_11-Jan-15.pdf PDF
DRAFT_443309_-_VOLUME_4_03-31-16.pdf PDF
DRAFT_CDC_Vol_3_of_3_11-Jan-15.pdf PDF
DRAFT_443309_-_VOLUME_1_03-31-16.pdf PDF
DRAFT_443309_-_VOLUME_2_03-31-16.pdf PDF
Show all 50

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

S U

BM

IT

T E D

B Y:

S

IZ

E:

FI

LE

N

O

IS

SU

E D

A T E:

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

C

KD

B Y:

US Army Corps of Engineers ®

X

A

P

LO

T

SC

AL

E:

P

LO

T D

A T E:

US

A rm y

Co rp s of

E ng in ee rs M id dl e Ea st D is tri ct M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

B

C

D

2 3 4 5 8/

/2

1:

:1

P M

8/

/2

1:

:1

PM

U N

SP

E C

IF

IE

D W

O R

L D W

ID

E

A

IR

D

EF

EN

SE

IM

PR

O V E

M

EN

TS

-0 7-

Enter District

EM

S

G W

D

R O

B

ER

T L.

F O

X , P

E

-G

I0

G N

G-012

JA

R

IN

D

EX

O

F

DR

A W

IN

G

S

VO

LU

M

E

SH

EE

T

P2 -4

G

EN

ER

A

L

INDEX OF DRAWINGS

443309-SITE DESIGN 06-ALJ

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

CIVIL

C-000 443309--CS000-6LS SITE 6 GRAPHIC REPRESENTATIONS

C-001 443309--CS001-6LS OVERALL PROJECTS LOCATION MAP

C-002 443309--CS002-6PN LAYDOWN AND HAUL ROUTE PLAN

C-100 443309--CS100-6PN03 3 AM#3 DEMOLITION PLAN

C-101 443309--CS101-6PN SITE 06 OVERALL PLAN

C-101A 443309--CS101A-6PN ALJ SITE 06 OVERALL SITE PLAN OPTIONAL BID ITEMS

C-102 443309--CS102-6PN03 3 AM#3 SITE PLAN SITE 6

C-103 443309--CS103-6PN SITE PLAN SITE 6

C-104 443309--CS104-6PN SITE PLAN SITE 6

C-105 443309--CS105-6PN SITE PLAN SITE 6

C-401 443309--CU401-6PN UTILITY PLAN SITE 6

C-402 443309--CU402-6PN UTILITY PLAN SITE 6

C-501 443309--CU501-6DT SANITARY SEWER HOLDINGS TANK DETAILS

C-502 443309--CU502-6DT LEACH FIELD PLAN

C-503 443309--CU503-6DT SEPTIC TANK AND LEACH FIELD DETAILS

C-504 443309--CU504-6DT LEACH FIELD DETAILS

C-505 443309--CU505-6DT EQUIPMENT PAD DETAILS

C-506 443309--CU506-6DT STORAGE FACILITY DETAILS

C-507 443309--CU507-6DT UTILITY DETAILS SITE 6

C-508 443309--CI508-6DT MISCELLANEOUS DETAILS

C-509 443309--CI509-6DT03 3 AM#3 PAVEMENT DETAILS

C-510 443309--CS510-6DT RADAR EXCLUSION ZONE DETAILS

C-511 443309--CS511-6DT CHAIN LINK SECURITY FENCE DETAILS

C-512 443309--CS512-6DT03 3 AM#3 FENCE DETAILS AND FORCE PROTECTION

C-513 443309--CS513-6DT FENCE DETAILS

C-514 443309--CS514-6DT DUMPSTER PAD AND DETAILS

C-541 443309--CS541-6DT03 3 AM#3 CANTILEVERED SLIDING GATE PLAN & ELEVATION

C-542 443309--CS542-6DT CANTILEVERED SLIDING GATE SECTIONS

C-543 443309--CS543-6DT CANTILEVERED SLIDING GATE DETAILS

SITE ELECTRICAL

XE-101 443309-SITE06--XE101PN05 6 AM#6 SITE ELECTRICAL POWER

XE-102 443309-SITE06--XE102PN05 6 AM#6 SITE ELECTRICAL POWER

XE-103 443309-SITE06--XE103PN SITE ELECTRICAL - LIGHTING PLAN LAYOUT

XE-104 443309-SITE06--XE104PN SITE ELECTRICAL - LIGHTING

XE-501 443309-SITE06--XE501DT ELECTRICAL DUCKBANK DETAIL

XE-502 443309-SITE06--XE502DT ELECTRICAL PULLBOX DETAIL

XE-601 443309-SITE06--XE601DI03 3 AM#3 SINGLE LINE DIAGRAM

SITE TELECOMMUNICATIONS

XT-101 443309-SITE06--XT101PN04 4 AM#4 TELECOMMUNICATIONS

XT-102 443309-SITE06--XT102PN04 4 AM#4 SITE TELECOMMUNICATIONS

XT-103 443309-SITE06--XT103PN04 4 AM#4 SITE TELECOMMUNICATIONS

XT-501 443309-SITE06--XT501DT MANHOLE WALL DETAIL 1

XT-502 443309-SITE06--XT502DT MANHOLE WALL DETAIL 2

XT-503 443309-SITE06--XT503DT MANHOLE WALL DETAIL 3

XT-504 443309-SITE06--XT504DT04 4 AM#4 DUCT BANK DETAIL 1

XT-505 443309-SITE06--XT505DT DUCT BANK DETAIL 2

XT-506 443309-SITE06--XT506DT DUCT BANK DETAIL 3

XT-507 443309-SITE06--XT507DT04 4 AM#4 DUCT BANK DETAIL 4

XT-508 443309-SITE06--XT508DT CABLE LADDER DETAIL

XT-509 443309-SITE06--XT509DT MANHOLE HARDWARE DETAILS

XT-510 443309-SITE06--XT510DT HANDHOLE AND COVER DETAILS

XT-511 443309-SITE06--XT511DT MANHOLE DETAILS

XT-512 443309-SITE06--XT512DT MANHOLE TO DUCT BANK CONNECTION DETAILS

XT-513 443309-SITE06--XT513DT CABLE RACKING DETAILS

XT-514 443309-SITE06--XT514DT CABLE RACKING DETAILS 2

XT-515 443309-SITE06--XT515DT CABLE RACKING DIAGRAMS 3

XT-516 443309-SITE06--XT516DT CABLE RACKING DIAGRAMS 4

XT-517 443309-SITE06--XT517DT CABLE RACKING DIAGRAMS 5

XT-518 443309-SITE06--XT518DT CABLE RACKING DIAGRAMS 6

XT-519 443309-SITE06--XT519DT CABLE RACKING DIAGRAMS 7

XT-520 443309-SITE06--XT520DT CABLE RACKING DETAILS 8

XT-521 443309-SITE06--XT521DT03 3 AM#3 LAUNCHER HANDHOLE AND TRENCH DETAIL

XT-522 443309-SITE06--XT601DT LAUNCHER HANDHOLE SITE DETAILS

XT-601 443309-SITE06--XT601DI04 6 AM#6 SITE COMMUNICATIONS ONE LINE DIAGRAMS

GENERAL VOLUME 2

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

GENERAL

G-001 450031-GI001GN COVER SHEET VOLUME 2 OF 4

G-004 450031-GI004GN INDEX OF VOLUMES

G-012 443309-GI012GN06 6 AM#6 INDEX OF DRAWINGS VOLUME 2 SHEET 1

G-013 443309-GI013GN06 6 AM#6 INDEX OF DRAWINGS VOLUME 2 SHEET 2

G-021 443309-GI021GN STANDARD LEGENDS AND SYMBOLOGY

G-031 443309-GI031GN STANDARD ABBREVIATIONS

443309A - ENGAGEMENT CONTROL STATION - SITE 06

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

STRUCTURAL

S-101 443309A-SB101PN COMPOSITE FOUNDATION AND SLAB PLAN

S-102 443309A-SB102PN PARTIAL FOUNDATION PLAN - WEST

S-103 443309A-SB103PN PARTIAL FOUNDATION PLAN - CENTER

S-104 443309A-SB104PN PARTIAL FOUNDATION PLAN - EAST

S-105 443309A-SF105PN COMPOSITE ROOF FRAMING PLAN

S-106 443309A-SF106PN PARITIAL ROOF FRAMING PLAN - WEST

S-107 443309A-SF107PN PARTIAL ROOF FRAMING PLAN - CENTER

S-108 443309A-SF108PN ROOF FRAMING PLANS

S-109 443309A-SF109PN PARTIAL ROOF FRAMING PLAN - EAST

S-401 443309A-SF401PN04 4 AM#4 ENLARGED STRUCTURAL PLANS

S-501 443309A-SB501DT STRUCTURAL DETAILS

S-502 443309A-SB502DT STRUCTURAL DETAILS

S-503 443309A-SB503DT STRUCTURAL DETAILS

S-601 443309A-SF601SC SCHEDULES

ARCHITECTURAL

A-001 443309A-AE001PN LIFE SAFETY & AIR BARRIER PLANS

A-101 443309A-AE101PN FLOOR PLAN

A-102 443309A-AE102PN ROOF PLAN

A-201 443309A-AE201EL NORTH SOUTH ELEVATIONS

A-202 443309A-AE202EL WEST EAST ELEVATIONS

A-203 443309A-AE203EL ELEVATIONS - AREA "B"

A-301 443309A-AE301SE SECTIONS

A-302 443309A-AE302SE SECTIONS

A-303 443309A-AE302SE RAMP SECTION

A-304 443309A-AE303SE WALL SECTIONS

A-305 443309A-AE304SE SECTIONS - AREA "B"

A-401 443309A-AE401LS ENLARGED FLOOR PLAN - AREA "A"

A-402 443309A-AE402LS ENLARGED FLOOR PLAN - AREA "B"

A-403 443309A-AE403LS REFLECTED CEILING PLAN - AREA "A"

A-404 443309A-AE404LS REFLECTED CEILING PLAN - AREA "B"

A-405 443309A-AE405LS ENLARGED TOILET PLAN

A-406 443309A-AE406EL SCREEN ROOM

A-501 443309A-AE501DT DETAILS

A-601 443309A-AE601SC DOOR AND FINISH SCHEDULES

PLUMBING

P-101 443309A-PL101PN GROUND FLOOR PLUMBING PLAN - STIE 06

P-102 443309A-PL102PN ROOF PLUMBING PLAN - SITE 06

P-401 443309A-PL401LS ENLARGED PLUMBING PLAN - SITE 06

P-901 443309A-PL901DI RISER DIAGRAMS-SITE 06

MECHANICAL

M-101 443309A-MH101PN GROUND FLOOR HVAC PLAN - SITE 06

M-401 443309A-MH401LS ENLARGED HVAC FLOOR PLAN - SITE 06

M-402 443309A-MH402LS ENLARGED TOILET ROOM PLAN - SITE 06

M-501 443309A-MH501DT FUEL TANK LAYOUT - SITE 06

M-601 443309A-MH601SC MECHANICAL SCHEDULES - SITE 06

ELECTRICAL

E-101 443309A-EP101PN POWER PLAN - AREA "A" - SITE 6 ALJ

E-102 443309A-EL102PN LIGHTING PLAN - AREA "A" - SITE 6 ALJ

E-103 443309A-EP103PN POWER PLAN - AREA " B" - SITE 6 ALJ

E-104 443309A-EL104PN LIGHTING PLAN - AREA " B"- SITE 06 ALJ

E-105 443309A-EP105PN LIGHTING AND POWER PLAN - RADAR RAMP - SITE 6

E-106 443309A-EP106PN04 4 AM#4 GROUNDING AND LIGHTNING PROTECTION PLAN

E-107 443309A-EP107PN04 4 AM#4 GROUNDING AND LIGHTNING PROTECTION PLAN "

AREA B"

E-601 443309A-EP601SC PANEL SCHEDULES - SITE 6

E-602 443309A-EP602SC PANEL SCHEDULE - SITE 6

TELECOMMUNICATIONS

T-101 443309A-TN101PN03 3 AM#3 TELECOMMUNICATIONS GROUND FLOOR PLAN - SITE 6

T-102 443309A-TN102PN04 4 AM#4 TELECOMMUNICATIONS CABLE TRAY PLAN - SITE 6

T-103 443309A-TN103PN03 3 AM#3 TELECOM SECURE VOICE PLAN - SITE 6

T-201 443309A-TN201EL03 3 AM#3 TELECOM ELEVATION DETAILS - SITE 6

T-501 443309A-TN501DT06 6 AM#6 TELECOM RM 108 ENLARGED FLOOR PLAN - SITE 6

T-502 443309A-TN502DT06 6 AM#6 TELECOM RM 108 CABINET & RACK DETAILS - SITE 6

443309B - HEADQUARTERS BUILDING - SITE 06

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

STRUCTURAL

S-101 443309B-SB101PN FOUNDATION AND SLAB PLAN SITE 06-ALJ

S-102 443309B-SF102PN ROOF FRAMING PLAN SITE 06-ALJ

S-601 443309B-SF601SC SCHEDULES SITE 06-ALJ

ARCHITECTURAL

A-001 443309B-AE001PN LIFE SAFETY PLAN - SITE 6 - ALJ

A-002 443309B-AE002PN AIR BARRIER PLAN - SITE 6 - ALJ

A-101 443309B-AE101PN FLOOR PLAN - SITE 6 - ALJ

A-102 443309B-AE102PN CEILING PLAN - SITE 6 - ALJ

A-103 443309B-AE103PN ROOF PLAN - SITE 6 - ALJ

A-201 443309B-AE201EL ELEVATIONS - SITE 06 - ALJ

A-301 443309B-AE301SE06 6 AM#6 SECTIONS- SITE 06- ALJ

A-401 443309B-AE401LS ENLARGED FLOOR PLAN- SITE 06-ALJ

A-601 443309B-AE601SC DOOR & WINDOW SCHEDULES - SITE 6 - ALJ

A-602 443309B-AE602SC FINISH SCHEDULE - SITE 6 - ALJ

PLUMBING

P-101 443309B-MP101PN SITE 6 DOMESTIC WATER FLOOR PLAN

P-102 443309B-MP102PN SITE 6 SANITARY FLOOR PLAN

P-103 443309B-MP103PN SITE 6 PLUMBING ROOF PLAN

P-401 443309B-MP401LS SITE 6 ENLARGED PLUMBING PLANS

P-402 443309B-MP402LS SITE 6 ENLARGED PLUMBING PLANS

P-403 443309B-MP403LS SITE 6 ENLARGED PLUMBING PLANS

P-901 443309B-MP901DI SITE 6 DOMESTIC WATER RISER DIAGRAM

P-902 443309B-MP902DI SITE 6 SANITARY RISER DIAGRAM

MECHANICAL

M-101 443309B-MH103PN SITE 6 HVAC FLOOR PLAN

M-102 443309B-MH104PN SITE 6 HVAC ROOF PLAN

M-601 443309B-MH602SC SITE 6 HVAC SCHEDULES

ELECTRICAL

E-101 443309B-EP101PN POWER FLOOR PLAN - SITE 6 - ALJ

E-102 443309B-EL102PN LIGHTING FLOOR PLAN - SITE 6 -ALJ

E-103 443309B-EP103PN ROOF POWER PLAN - SITE 6 - ALJ

E-104 443309B-EP104PN GROUNDING PLAN - SITE 6 ALJ

E-601 443309B-EP601SC PANEL SCHEDULES - SITE 6 - ALJ

E-602 443309B-EP602SC PANEL SCHEDULES - SITE 6 - ALJ

TELECOMMUNICATIONS

T-101 443309B-TN101PN04 4 AM#4 TELECOM FLOOR PLAN - SITE 6

T-102 443309B-TN102PN03 3 AM#3 SECURE VOICE FLOOR PLAN - SITE 6

T-401 443309B-TN401LS06 6 AM#6 ENLARGED TELECOM RM 119 - SITE 6

T-402 443309B-TN402LS03 3 AM#3 ENLARGED TELECOM RM 106E - SITE 6

T-501 443309B-TN501DT06 6 AM#6 COMM RACK DETAIL SITE 6

443309C - TOILET BUILDING

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

STRUCTURAL

S-101 443309C-SB101PN FOUNDATION AND SLAB PLAN

S-102 443309C-SF102PN ROOF FRAMING PLAN

S-601 443309C-SF601SC SCHEDULES

ARCHITECTURAL

A-001 443309C-AE001PN LIFE SAFETY PLAN

A-002 443309C-AE002PN AIR BARRIER PLAN

A-101 443309C-AE101PN FLOOR AND ROOF PLAN

A-102 443309C-AE102PN REFLECTED CEILING PLAN

A-201 443309C-AE201EL ELEVATIONS

A-301 443309C-AE301SE SECTIONS

A-302 443309C-AE302SE WALL SECTIONS

A-401 443309C-AE401EL INTERIOR ELEVATIONS

A-601 443309C-AE601SC DOOR AND FINISH SCHEDULES

PLUMBING

P-101 443309C-PL101PN GROUND FLOOR PLUMBING PLAN - SANITARY

P-102 443309C-PL102PN GROUND FLOOR PLUMBING PLAN - DOMESTIC WATER

P-103 443309C-PL103PN PLUMBING ROOF PLAN

P-901 443309C-PL901IS PLUMBING RISER DIAGRAM - SANITARY

P-902 443309C-PL902IS PLUMBING RISER - DOMESTIC WATER

MECHANICAL

M-101 443309C-MH101PN GROUND FLOOR HVAC PLAN

ELECTRICAL

E-101 443309C-EP101PN POWER, LIGHTING AND GROUNDING PLAN

E-601 443309C-EP601SC PANEL SCHEDULE

M

AR

K D

ES

C

R

IP

TI

O

N D

A

TE

A P

PR

A M

E N

D M

EN

T

#3

/2 5/

A

M E

N D

M

EN

T #4

/0

2/

A M

E N

D M

EN

T

#6

/1 8/

D R

AW

N

B Y:

D

ES

IG

N

B Y:

S U

BM

IT

T E D

B Y:

S

IZ

E:

FI

LE

N

O

IS

SU

E D

A T E:

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

C

KD

B Y:

US Army Corps of Engineers ®

X

A

P

LO

T

SC

AL

E:

P

LO

T D

A T E:

US

A rm y

Co rp s of

E ng in ee rs M id dl e Ea st D is tri ct M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

B

C

D

2 3 4 5 8/

/2

:4

0:

P M

8/

/2

:4 0:

P

M

U N

SP

E C

IF

IE

D W

O R

L D W

ID

E

A

IR

D

EF

EN

SE

IM

PR

O V E

M

EN

TS

-0 7-

Enter District

EM

S

G W

D

R O

B

ER

T L.

F O

X , P

E

-G

I0

G N

G-013

JA

R

IN

D

EX

O

F

DR

A W

IN

G

S

VO

LU

M

E

SH

EE

T

P2 -4

G

EN

ER

A

L

INDEX OF DRAWINGS

443309E - GUARD TOWER

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

STRUCTURAL

S-101 443309E-SB101PN FOUNDATION AND SLAB PLAN

S-401 443309$-SS507DT MAT FOUNDATION DETAILS

ARCHITECTURAL

A-001 443309E-AE001PN LIFE SAFETY PLAN

A-101 443309E-AE101PN FLOOR AND ROOF PLAN

A-102 443309E-AE102PN REFLECTED CEILING PLAN

A-201 443309E-AE201EL ELEVATIONS

A-301 443309E-AE301SE BUILDING SECTIONS

A-302 443309E-AE302SE STAIR SECTION & DETAILS

A-601 443309E-AE601SC DOOR AND FINISH SCHEDULES

MECHANICAL

M-101 443309E-MH101PN HVAC FLOOR PLAN

ELECTRICAL

E-101 443309E-EP101PN03 3 AM#3 POWER, LIGHTING AND GROUNDING PLAN

TELECOMMUNICATIONS

T-101 443309E-TN101PN03 3 AM#3 TELECOM FLOOR PLAN

T-201 443309E-TN201EL03 3 AM#3 TELECOM EAST ELEVATION

T-202 443309E-TN202EL03 3 AM#3 TELECOM NORTH ELEVATION

443309F - CAR PARKING SHELTER

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

STRUCTURAL

S-101 443309F-SB101PN FOUNDATION AND SLAB PLAN

ARCHITECTURAL

A-101 443309F-AE101PN PLANS

A-201 443309F-AE201EL ELEVATIONS

A-301 443309F-AE301SE SECTIONS

ELECTRICAL

E-101 443309F-EP101PN POWER, LIGHTING AND GROUNDING

443309G - TRUCK PARKING SHELTER

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

STRUCTURAL

S-101 443309G-SB101PN FOUNDATION AND SLAB PLAN

ARCHITECTURAL

A-101 443309G-AE101PN FLOOR PLAN

A-102 443309G-AE102PN ROOF PLAN

A-103 443309G-AE103PN REFLECTED CEILING PLAN

A-201 443309G-AE201EL ELEVATIONS

A-202 443309G-AE202EL ELEVATIONS

A-301 443309G-AE301SE BUILDING SECTIONS

ELECTRICAL

E-101 443309G-EP101PN POWER, LIGHTING AND GROUNDING PLAN

443309H - STORAGE FACILITY

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

STRUCTURAL

S-101 443309H-SB101PN FOUNDATION AND SLAB PLAN

ARCHITECTURAL

A-101 443309H-AE101PN FLOOR PLAN

A-102 443309H-AE102PN ROOF PLAN

A-103 443309H-AE103PN REFLECTED CEILING PLAN

A-201 443309H-AE201EL ELEVATIONS

A-202 443309H-AE202EL ELEVATIONS

A-301 443309H-AE301SE BUILDING SECTIONS

ELECTRICAL

E-101 443309H-EP101PN04 4 AM#4 LIGHTING, POWER, GROUNDING AND LIGHTNING

PROTECTION PLANS

443309I - FREQUENCY CONVERTER - PDU SHELTER

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

STRUCTURAL

S-101 443309I-SB101PN FOUNDATION AND SLAB PLAN

S-102 443309I-SF102PN ROOF FRAMING PLAN

S-601 443309I-SB601SC SCHEDULES

ARCHITECTURAL

A-001 443309I-AE001PN LIFE SAFETY PLAN

A-002 443309-AE002PN AIR BARRIER PLAN

A-101 443309I-AE101PN FLOOR PLAN

A-201 443309I-AE201EL ELEVATIONS

A-301 443309I-AE301SE SECTIONS

A-601 443309I-AE601SC DOOR AND FINISH SCHEDULES

MECHANICAL

M-101 443309I-MH101PN HVAC FLOOR PLAN

ELECTRICAL

E-101 443309I-EP101PN04 4 AM#4 POWER, LIGHTING AND GROUNDING PLAN

E-601 443309I-EP601SC PANEL SCHEDULES

E-602 443309I-EP602SC PANEL SCHEDULES

443309L - POWER PLANT FACILITY - SITE 06

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

STRUCTURAL

S-101 443309L-SB101PN FOUNDATION & ROOF FRAMING PLAN

S-601 443309L-SF601SC SCHEDULES

ARCHITECTURAL

A-001 443309L-AE001PN LIFE SAFETY PLAN

A-002 443309L-A002PN AIR BARRIER PLAN

A-101 443309L-AE101PN FLOOR PLAN

A-102 443309L-AE102PN REFLECTED CEILING PLAN

A-201 443309L-AE201EL ELEVATIONS

A-301 443309L-AE301SE BUILDING SECTIONS

A-601 443309L-AE601SC06 6 AM#6 DOOR & FINISH SCHEDULES

MECHANICAL

M-101 443309L-M101PN GROUND FLOOR HVAC PLAN

ELECTRICAL

E-101 443309L-EP101PN GROUNDING, POWER AND LIGHTING PLAN

E-601 443309L-EP601SC PANEL SCHEDULES - SITE 6

E-602 443309L-EP602SC PANEL SCHEDULES - SITE 6

TELECOMMUNICATIONS

T-101 443309L-TN101PN03 3 AM#3 COMMUNICATIONS FLOOR PLAN

T-501 443309L-TN502DT03 3 AM#3 COMM ENTRANCE & CABINET DETAIL

443309M - PRAYER/GATHERING BUILDING

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

MECHANICAL

M-101 443309M-MH101PN GROUND FLOOR HVAC PLAN

M-102 443309M-MH102PN ROOF HVAC PLAN

ELECTRICAL

E-101 443309M-EP101PN POWER PLAN

E-601 443309M-EP601SC PANEL SCHEDULE

TELECOMMUNICATIONS

T-101 443309M-TN101PN03 3 AM#3 COMMUNICATIONS FLOOR PLAN

T-501 443309M-TN501PN 6 PAIR PROTECTIVE ENTRANCE TERMINAL (PET)

443309M - PRAYER/GATHERING BUILDING

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

STRUCTURAL

S-101 443309M-SB101PN FOUNDATION AND SLAB PLAN

S-102 443309M-SF102PN ROOF FRAMING PLAN

S-601 443309M-SF601SC SCHEDULES

ARCHITECTURAL

A-001 443309M-AE001PN LIFE SAFETY PLAN

A-002 443309M-AE002PN AIR BARRIER PLAN

A-101 443309M-AE101PN GROUND FLOOR PLAN

A-102 443309M-AE102PN ROOF PLAN

A-103 443309M-AE103PN REFLECTED CEILING PLAN

A-201 443309M-AE201EL ELEVATIONS

A-301 443309M-AE301SE SECTIONS

A-302 443309M-AE302SE WALL SECTIONS

A-501 443309M-AE501DT DETAILS

A-502 443309M-AE502DT DETAILS

A-601 443309M-AE601SC DOOR, WINDOW AND FINISH SCHEDULES

443309N - FUEL DISPENSING SUNSHADE

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

STRUCTURAL

S-101 443309N-SB101PN FOUNDATION AND SLAB PLAN

ARCHITECTURAL

A-101 443309N-AE101PN PLANS

A-201 443309N-AE201EL ELEVATIONS

A-301 443309N-AE301SE SECTIONS

MECHICANICAL

M-101 443309N-MH101PN MECHANICAL PLAN

M-102 443309N-MH102PN FUEL TANK LAYOUT

M-301 443309N-M301SE MECHANICAL SECTION

M-501 443309N-MH501DT FUEL TANK LAYOUT

ELECTRICAL

E-101 443309N-EP101PN LIGHTING, POWER PLAN AND GROUNDING

443309D - GUARD HOUSE

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

STRUCTURAL

S-101 443309D-SB101PN FOUNDATION AND SLAB PLAN

S-102 443309D-SF102PN03 3 AM#3 ROOF FRAMING PLAN

S-401 443309D-SF401DT CONCRETE DETAILS

S-601 443309D-SF601SC03 3 AM#3 SCHEDULES

ARCHITECTURAL

A-001 443309D-AE001PN LIFE SAFETY PLAN

A-002 443309D-AE002PN AIR BARRIER PLAN

A-101 443309D-AE101PN FLOOR PLAN

A-201 443309D-AE201EL ELEVATIONS

A-301 443309D-AE301SE SECTIONS

A-302 443309D-AE302SE WALL SECTIONS

A-401 443309D-AE401LS TOILET PLAN

A-601 443309D-AE601SC DOOR & FINISH SCHEDULES

PLUMBING

P-101 443309D-PL101PN PLUMBING WASTE PLANS

P-102 443309D-PL102PN PLUMBING WATER PLANS

P-301 443309D-PL301SE PLUMBING SECTIONS

P-901 443309D-PL901IS PLUMBING RISER DIAGRAMS

MECHANICAL

M-101 443309D-MH101PN GROUND FLOOR HVAC PLAN

ELECTRICAL

E-101 443309D-EP101PN POWER, LIGTHING AND GROUNDING PLAN

TELECOMMUNICATIONS

T-101 443309D-TN101PN03 3 AM#3 COMMUNICATIONS FLOOR PLAN

T-501 443309D-TN501DT03 3 AM#3 COMM ENTRANCE DETAIL

443309N2 - FUEL TRUCK PARKING SUNSHADE

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

STRUCTURAL

S-101 443309N2-SB101PN FOUNDATION AND SLAB PLAN

ARCHITECTURAL

A-101 443309N2-AE101PN PLANS

A-201 443309N2-AE201EL ELEVATIONS

A-301 443309N2-AE301SE SECTIONS

ELECTRICAL

E-101 443309N2-EP101PN LIGHTING, POWER PLAN AND GROUNDING

443309O - EQUIPMENT PADS

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

ELECTRICAL

E-101 443309O-EP101PN POWER AND GROUNDING PLAN

443309P - MAINTENANCE HIGH-BAY

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

STRUCTURAL

S-101 443309P-SB101PN FOUNDATION AND SLAB PLAN

S-102 443309P-SF102PN BRIDGE CRANE SUPPORT SYSTEM PLAN

S-401 443309P-SB401DT MASONRY AND MBS FOUNDATION DETAILS

S-601 443309P-SB601SC SCHEDULES

ARCHITECTURAL

A-001 443309P-AE001PN LIFE SAFETY PLAN

A-002 443309P-AE002PN AIR BARRIER PLAN

A-101 443309P-AE101PN FLOOR PLAN

A-102 443309P-AE102PN ROOF PLAN

A-103 443309P-AE103PN REFLECTED CEILING PLAN

A-201 443309P-AE201EL ELEVATIONS

A-301 443309P-AE301SE BUILDING SECTIONS

A-302 443309P-AE301SE WALL SECTIONS

A-601 443309P-AE601SC DOOR AND FINISH SCHEDULES

PLUMBING

P-101 443309P-PL101PN GROUND FLOOR PLUMBING PLAN

MECHANICAL

M-101 443309P-MH101PN GROUND FLOOR HVAC PLAN

ELECTRICAL

E-101 443309P-EP101PN GROUNDING AND POWER PLAN

E-102 443309P-EL102PN LIGHTING PLAN

E-601 443309P-EP601SC PANEL SCHEDULE

M

AR

K D

ES

C

R

IP

TI

O

N D

A

TE

A P

PR

A M

E N

D M

EN

T

#3

/2 5/

A

M E

N D

M

EN

T #4

/0

2/

A M

E N

D M

EN

T

#6

/1 8/

PDU-2

PDU-3

CONVERTER

FREQUENCY

CONVERTER

FREQUENCY

CONVERTER

FREQUENCY

ALASKA BARRIERS

EQUIPMENT PAD WITH

CU-E3

CU-E4

EMH-5EMH-6

EMH-8

EMH-9 EMH-7

400HZ

PDU-1

MDPI-1

MDPI-3

MDPI-2

UE

UE

UE

UE

P

UE

400HZ

U E

H Z

U E

H Z

H Z

U E

PAD

EQUIPMENT

PAD

EQUIPMENT

EMH-4

UE

UE

UE

UE

P

P T

ZP

T Z

GUARD TOWER

TOWER

GUARD

XE-103 FOR ADDITIONAL INFORMATION.

THE SAME LIGHTING POLE, REFER TO SHEET

ALL CAMERAS SHALL BE POLE MOUNTED IN

INFORMATION.

SHEET XE-103 FOR ADDITIONAL

IN THE SAME LIGHTING POLE, REFER TO

ALL CAMERAS SHALL BE POLE MOUNTED

PB-7

UE

UE

UE

UE

PB-8 PB-9

TYPE 2

DUCT BANK

TYPE 2

DUCT BANK

TYPE 6

DUCT BANK

TYPE 2

DUCT BANK

TYPE 2

DUCT BANK

TYPE 2

DUCT BANK

TYPE 2

DUCT BANK

TYPE 2

DUCT BANK

TYPE 2

DUCT BANKTYPE 2

DUCT BANK

TYPE 2

DUCT BANK

TYPE 2

DUCT BANK

TYPE 2

DUCT BANK

ALASKA BARRIERS

EQUIPMENT PAD WITH

ALASKA BARRIERS

EQUIPMENT PAD WITH

ALASKA BARRIERS

EQUIPMENT PAD WITH

ALASKA BARRIERS

EQUIPMENT PAD WITH

TYPE 2

DUCT BANK

UE

TYPE 2

DUCT BANK

X X

X

XX

X X

X

X X

X

XX

X X

X

X X

X

XX

X X

X

X X

X

XX

X X

X

X X

X

XX

X X

X

XX XX

X X

X

X XX

X X

X

X X

X

XX

X X

X

X X

X

XX

X X

X

PAD

EQUIPMENT

PAD

EQUIPMENT

SHEET ID

X

Middle East District of Engineers

US Army Corps

U S A rm y C o rp s o f

E n g in e e rs

M id d le E a s t

D is tr ic t

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

D A

T E

A P

P R

/1

/2 c u s e r s n e n e ia d o c u m e n t s p w w o r k d

S

IT

E

X E P

N .d g n n e n e ia

-0

-1

A

IR

D

E F

E N

S E I

M P

R O

V E

M E

N T S

U N

S P

E C

IF

IE

D W

O R

L D

W

ID

E

P

-4

DIMENSIONS SHOWN ARE IN MILLIMETERS.

UNLESS OTHERWISE NOTED, LINEAR

NN

CONTINUED ON SHEET XE102

D A

V E C

L A

R K

E

IA

/F

G

IA M

M

C h ie f, E le c tr ic a l B ra n c h

XE-101

S

IT

E

A

L J

S

IT

E E

L E

C T

R

IC

A L P

O W

E R

11 1

GENERAL SHEET NOTES SHEET KEYNOTES

OF EQUIPMENT PADS.

6. REFER TO SHEET OE-101 FOR ELECTRICAL DETAILS

ON GUARD TOWERS.

QUANTITY OF SECURITY CAMERAS THAT ARE MOUNTED

5. REFER TO SHEET EE-101 FOR THE LOCATION AND

SYSTEM WITH COMMUNICATION SYSTEMS.

4. COORDINATE LOCATION OF UNDERGROUND ELETRICAL

AND CAMERA DETAILS.

3. REFER TO SE-601 FOR CAMERA RISER DIAGRAM

AND SHEET LE-601 FOR FEEDER AND CONDOUIT SIZES.

2. REFER TO SHEET 2XE-601 FOR ONE LINE DIAGRAM

GENERAL NOTES AND ABBREVIATIONS.

1. REFER TO SHEET SE-001 FOR ELECTRICAL LEGEND,

1:1000

10 10 20 30 40 50 60 70 80 900

1:1000

10 10 20 30 40 50 60 70 80 90

SCALE = 1:1000

SITE ELECTRICAL POWER

ENCLOSURES.

SYSTEM SHALL BE PROVIDED IN NEMA 4X

INSTALLED ON THE POLES TO FEED THE CAMERA

CAMERAS. EXTERIOR ELECTRICAL ENCLOUSURE

TO OBTAIN REQUIRED DC VOLTAGE FOR THE

PROVIDE TRANSFORMER OR RECTIFIERS AS REQUIRED

WEATHERPROOF SOCKET CIRCUIT ON THE POLE.

CAMERAS SHALL PROVIDED FROM THE

THE CONTRACT SPECIFICATIONS. POWER TO THE

AND MONITORING FOR CAMERAS AS SPECIFIED IN

COORDINATION TO OBTAIN REQUIRED VISIBILITY

CONTRACTOR IS TO MAKE PROPER FIELD

TO THE LAUNCHERS MANHOLE.

WIRES FROM EACH FREQUENCY CONVERTER/PDU

2 SETS OF 100MM EMPTY CONDUIT WITH PULL

LAUNCHER WILL BE PROVIDED BY OTHERS. PROVIDE

CONDUCTORS FROM FREQUENCY CONVERTER TO

FUTURE USE.

OF 1.5M FROM EACH SIDE AND BE CAPPED FOR

CONDUIT, THE CONDUIT SHALL EXTEND A MINIMUM

PROVIDED WITH ONE SCHEDULE 40 PVC SPARE

UNDER ROADWAYS, STREETS AND PARKING AREAS.

SCHEDULE 40 PVC CONDUIT, CONCRETE ENCASE

CONDUCTORS SHALL BE IN DIRECT BURIED

A

M E

N D

M E

N T

/1

/2

-S

IT

E

X E P

N

W

MOUNTED IN GUARD TOWER

ALL CAMERAS ARE WALL

MOUNTED IN GUARD TOWER

ALL CAMERAS ARE WALL

W

PZT

MDPA

MDP1

MDPD

MDPP

CU-H

MDPB

MDPM

MDPC

CU-F

CU-E1

CU-E2

PP-N

TOWER

COMM

MDPB1

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

EMH-3

UE

UE

GUARD TOWER

GUARD TOWER

CU-N2

EMH-2

CU-G

EMH-1

PB-3

PB-4

PB-5

PB-6

TYPE 2

DUCT BANK

TYPE 4

DUCT BANK

TYPE 6

DUCT BANK

TYPE 6

DUCT BANK

TYPE 2

DUCT BANK

TYPE 12

DUCT BANK

TYPE 16

DUCT BANK

UE UE

TYPE 16

DUCT BANK

PB-1

PB-12

TYPE 4

DUCT BANK

TYPE 2

DUCT BANK

TYPE 2

DUCT BANK

TYPE 2

DUCT BANK

UE

TYPE 4

DUCT BANK

TYPE 6

DUCT BANK

TYPE 6

DUCT BANK

TYPE 6

DUCT BANK

TYPE 2

DUCT BANK

TYPE 2

DUCT BANK

TYPE 2

DUCT BANK

TYPE 2

DUCT BANK

TYPE 2

DUCT BANK

X X

X X

XXXX

XXXX

M E C

C A

X X

X X

X

X XX XX XX

M E C

C A

M E C

C A

XXXX

XXXX

ECS

A N

D S

U N

S H

A D

E

S T

O R

A G

E A

R E

A

PARKING

COVERED TRUCK

AREA

GATHERING

BUILDING

TOILET

P L

A N

T

P O

W E

R

AND SUNSHADE

FUEL STORAGE TANK

COMMUNICATION TOWER

FIELD

LEACH

SUNSHADE

TRUCK PARKING

FUEL TANKER

HOUSE

GUARD

BUILDING

HEADQUARTERS

SHEET ID

X

Middle East District of Engineers

US Army Corps

U S A rm y C o rp s o f

E n g in e e rs

M id d le E a s t

D is tr ic t

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

D A

T E

A P

P R

/1

/2 c u s e r s n e n e ia d o c u m e n t s p w w o r k d

S

IT

E

X E

P N

.d g n n e n e ia

-0

-1

A

IR

D

E F

E N

S E I

M P

R O

V E

M E

N

S P

E C

IF

IE

D W

O R

L D

W

ID

-4

NN

CONTINUED ON SHEET XE101

D A

V E C

L A

R K

E

IA M

M

C h ie f, E le c tr ic a l B ra n c h

XE-102

S

IT

E

A

L J

S

IT

E E

L E

C T

R

IC

A L P

O W

E R

IA

/F

G

GENERAL SHEET NOTES

SHEET KEYNOTES

ON GUARD TOWERS.

QUANTITY OF SECURITY CAMERAS THAT ARE MOUNTED

5. REFER TO SHEET EE101 FOR THE LOCATION AND

SYSTEM WITH COMMUNICATION SYSTEMS.

4. COORDINATE LOCATION OF UNDERGROUND ELETRICAL

AND CAMERA DETAILS.

3. REFER TO SE-601 FOR CAMERA RISER DIAGRAM

AND SHEET LE-601 FOR FEEDER AND CONDOUIT SIZES.

2. REFER TO SHEET 2XE-601 FOR ONE LINE DIAGRAM

GENERAL NOTES AND ABBREVIATIONS.

1. REFER TO SHEET SE-001 FOR ELECTRICAL LEGEND,

FUTURE USE.

OF 1.5M FROM EACH SIDE AND BE CAPPED FOR

CONDUIT, THE CONDUIT SHALL EXTEND A MINIMUM

PROVIDED WITH ONE SCHEDULE 40 PVC SPARE

UNDER ROADWAYS, STREETS AND PARKING AREAS.

SCHEDULE 40 PVC CONDUIT, CONCRETE ENCASE

CONDUCTORS SHALL BE IN DIRECT BURIED

1:1000

10 10 20 30 40 50 60 70 80 900

1:1000

10 10 20 30 40 50 60 70 80 90

SCALE = 1:1000

SITE ELECTRICAL POWER

A

M E

N D

M E

N T

/1

/2

-S

IT

E

X E P

N

HIGH BAY

MAINTENANCE

X fi

Middle East District of Engineers

US Army Corps

U S A rm y C o rp s o f

E n g in e e rs

M id d le E a s t

D is tr ic t

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

D A

T E

A P

P R

/1

/2 c u s e r s n e n e d b i\ d o c u m e n t s p w w o r k d

S

IT

E

X T

D I0

.d g n n e n e d b i

-0

-1

A

IR

D

E F

E N

S E I

M P

R O

V E

M E

N

S P

E C

IF

IE

D W

O R

L D

W

ID

-4

DIM. NOTE & NORTH

NN

S

IT

E

A

L J

D A

V

ID

S

C L

A R

K E P .E

D I

C H

D I

C h ie f, E le c tr ic a l B ra n c h

S

IT

E C

O M

M U

N

IC

A T

IO

N S

O N

E L

IN

E D

IA

G R

A M

XT-601

CONTROL MODULE

ICC/ECS

PDU

STORAGE

PDU

PDU

LAUNCHERS

SITE COMMUNICATIONS

ONE LINE DIAGRAM

TOWER

GUARD

TOWER

GUARD

TOWER

GUARD HQ

LAUNCHERS

LAUNCHERS

LAUNCHERS

LAUNCHERS

PRAYER BUILDING

1, 1-6

P6x-24 PF

PLANT

POWER

ECP

2, 1-6

P6x-24 PF

2, 7-12

P6x-24 PF

LEFT IN CLOSURE

CLEARED AND CAPPED

CABLE 2, PAIRS 13-25

2,1-25

P25x-24PF

FCOMM, 1-48, 48 SM

1, 1-100

P1-24PF

NON TACTICAL CABLE SYSTEM

2, 26-31

P6x-24 PF

2, 32-43

P12x-24 PF

CAPPED

CLEARED AND

PAIR 50

1, 20-25

P6x-24 PF

CAPPED

CLEARED AND

PAIRS 7-19

2, 44-49

P6x-24 PF

FSV, 1-24, 24 SM

FSV, 1-24, 24 SM

FCOMM, 1-48, 48 SM

(POINT OF PRESENCE)

POP HANDHOLE

MH 6

MH 5

MH 4

MH 3

MH 8

MH 7HH 7

MH 10

MH 1

MH 2

NOT TO SCALE, LOCATIONS ARE GENERAL

MH 11

MH 12

MH 13

MH 14

HH 14

MH 15

HH 15

1,1-100

P1-24PF

1,1-25

P25-24PF

1,1-25

P25-24PF

CAMERAS

TOWER

GUARD

CAMERAS

CAMERAS

CAMERAS

PROVIDED BY THE CONTRACTOR.

MEDIA CONVERTERS FOR THE CAMERAS TO BE

TO BE BROKEN OUT IN THE TERMINAL CABINET (s). ANY

TO THE TOWER AND ECP. STRANDS TO EACH CAMERA

MULTI-DUCTS. ONE FIBER CABLE TO BE INSTALLED

NOT SHOWN BUT WILL BE INSTALLED IN ONE OF THE 38mm

1. SOUTH TOWERS: CABLE FROM THE SECURITY CAMERAS ARE

REQUIREMENTS.

REFER TO SECTION 27 10 00 FOR THE FIBER OPTIC HARDWARE

CONVERSION, ECT.) TO MAKE THE CAMERAS OPERATIONAL.

SPLICED PIGTAILS AND ALL OTHER HARDWARE (MEDIA

TO ALSO CONTAIN A FIBER PATCH PANEL, SPLICE TRAY, FUSION

HARDWARE REQUIRED TO POWER THE CAMERAS. ENCLOSURE

VOLTAGE PROTECTION, TRANSFORMERS ECT.) AND ALL OTHER

EQUIPPED WITH POWER EQUIPMENT (OVER CURRENT/OVER

TO BE BROKEN OUT IN THE ENCLOSURE. ENCLOSURE TO BE

BASE OF THE LIGHT POLE. STRANDS TO EACH CAMERA

CABLE TO BE INSTALLED TO A NEMA 4 ENCLOSURE AT THE

MULTI-DUCTS FROM A HANDHOLE (HH 14 , HH 15). ONE FIBER

NOT SHOWN BUT WILL BE INSTALLED IN ONE OF THE 38mm

2. NORTH TOWERS: CABLE FROM THE SECURITY CAMERAS ARE

HH 2

FCM 3, 1-18,18SM

FCM 3,1-24, 24 SM

LEFT IN SPLICE CLOSURE

FCM 3, 19-24

FCM 3,1-24, 24 SM

FCM 3,1-24, 24 SM

FCM 1, 1-48, 48 SM

FCM 1,1-48, 48 SMFCM 1,1-48, 48 SM

FCM 1,1-48, 48 SM

FCM 1,1-48, 48 SM

FCM 1,1-24, 24 SM

FCM 1,1-18, 18 SM

FCM 1, 25-48, 48 M

FCM 1,25-48, 24 SM

IN SPLICE CLOSURE

FCM 1,19-24

FCM 1,25-42, 18 SM

IN SPLICE CLOSURE

FCM 1,42-48

AND CAPPED

1-25 CLEARED

2,26-100 +

P1-24PF

FCM 2,1-24, 24 SM

FCM 2,1-18, 18 SM

FCOMM, 1-48, 48 SM

FSV, 1-24, 24 SM

2, 1-6

P6x-24 PF

FCM 1

FIBER SPLICE

2, 51-75, 51-56 DD

P25X-24 PF

1,1-100 (TO ECS)

P1-24PF

2, 26-100, 1-25 DD

P1-24PF

FCM 2, 1-24, 24 SM

DD = DEAD PAIR COUNT

HH12AHH12B

SHEET NOTES

-S

IT

E

X T

D I0

FCM FIBER, CAMERAS, (CONSTRUCTION CONTRACT).

FSV FIBER, SECURE VOICE, (CONSTRUCTION CONTRACT)

A M

E N

D M

E N

T

/2 /2

FCOMM FIBER (CONSTRUCTION CONTRACT)

(48 SM) - 48 STRAND, SINGLE MODE

(1-48) - FIBER STRAND COUNT

(FCOMM) - CABLE IDENTIFIER

FCOMM, 1-48, 48 SM,

FIBER CABLE

(1) - CABLE NUMBER, (1-25) - PAIR COUNT

(PF) - POLYETHYLENE FOAM SKINNED INSULATION

(24) - 24 AWG CABLE

(12x) - PAIR SIZE OF CABLE, x SIGNIFIES LESS THAN 25 PR

(P) - POLYETHYLENE INSULATED CONDUCTOR

1, 1-25

P-12x-24 PF

COPPER CABLE

3. CABLE LEGEND:

FCM 2,19-24, 6 SM 6

A

M E

N D

M E

N T

/1

/2

3 - 115mm

O.D. CONDUIT

TO MH11

TMGB

RACK #1

RACK #2

100 PR

PET

COAX SWING-

DOWN RACK

305mm (WIDTH)

CABLE LADDER

CABINET #1 CABINET #2

SECURE VOICE SYSTEM PDS

86mm X 152mm, 2850mm AFF (SEE SHEET(s) T-103, T-113)

SECURE VOICE SYSTEM

SWING-OUT RACK

6 - 115mm

O.D. CONDUIT

TO MH-10

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

S U

BM

IT

T E D

B Y:

S

IZ

E:

FI

LE

N

O

IS

SU

E D

A T E:

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C

KD

B Y:

US Army Corps of Engineers ®

X

A

P

LO

T

SC

AL

E:

P

LO

T D

A T E:

US

A rm y

Co rp s of

E ng in ee rs M id dl e Ea st D is tri ct

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

B

C

D

2 3 4 5 8/

/2

1:

:3

P M

8/

/2

1:

:3

PM

U N

SP

E C

IF

IE

D W

O R

L D W

ID

E

A

IR

D

EF

EN

SE

IM

PR

O V E

M

EN

TS

-0 7-

- C O

N

TR

AC

T

N U

M

BE

R

Middle East District

C H

D I

D

AV

E S

. C

LA

R

KE

A-

TN

1D T0

T-501

W

IN

C H

E

ST

E R

, V A

D I

TE

L E

C O

M R

M

E

N

LA

RG

ED

F L O

O R

PL

A

N

S I

TE

A

P2 -4

EN

G

A G

EM

EN

T C

O

NT

RO

L

ST

A

TI

O

N 1 : 20

ENLARGED COMM RM 108 - SITE 6

M

AR

K D

ES

C

R

IP

TI

O

N D

A

TE

A P

PR

A M

E N

D M

EN

T

#3

/2 5/

A

M E

N D

M

EN

T #6

/1

8/

1:20

2m0.4m 1.6m1.2m0.8m0m

SHEET NOTES:

NOTE 1) COPPER CABLING SHALL BE PROVIDED BY THE

CONTRACTOR IN ORDER TO CONNECT THE 100 PAIR PET

TO VOICE PATCH PANELS IN THE VOICE CABINET.

NOTE 1

NOTE 1

NOTE 3

NOTE 1

NOTE 2

48 STRAND, OSP SINGLE MODE FIBER TO HQs COMM

ROOM FOR VOICE/DATA CONNECTION

CABINET 1 CABINET 2 RACK 1

(SPARE)

RACK 2

SECURE VOICE

SYSTEM

NOTE 1

NOTE 1

NOTE 1

NOTE 4

24 STRAND, OSP SINGLE MODE FIBER TO HQs COMM

ROOM FOR SECURE VOICE NETWORK CONNECTION

NOTE 3

48 STRAND, SM FOC

FCM 1, 1-48, 48SM

TO MH11

48 STRAND, SM FOC

FCM-1, 1-48, 48SM

TO HQ BUILDING

NOTE 8

NOTE 1

NOTE 1: 2 RMU HORIZONTAL CABLE MANAGEMENT BAR

NOTE 2: 4 RMU FIBER OPTIC COMBINATION UNIT WITH

FOUR (4) SINGLE MOCE SC CONNECTOR PANELS

AND TWO (2) BLANK PANELS. PROVIDE NINETY-SIX

(96) SINGLE MODE PATCH CORDS SC-SC.

FCOMM 48SM, FCM 48SM.

NOTE 3: 48 PORT, CATEGORY 6, UTP PATCH PANEL.

PROVIDE FORTY-EIGHT (48) CATEGORY 6 GREEN

PATCH CORDS, RJ45-RJ45.

NOTE 4: 4 RMU FIBER OPTIC COMBINATION UNIT WITH

TWO (2) SINGLE MOCE SC CONNECTOR PANELS

AND TEN (10) BLANK PANELS. PROVIDE TWENTY-

FOUR (24) SINGLE MODE PATCH CORDS SC-SC.

NOTE 5: 24 PORT, CATEGORY 6, UTP PATCH PANEL.

PROVIDE TWENTY-FOUR (24) CATEGORY 6 GREEN

PATCH CORDS, RJ45-RJ45.

NOTE 6: CABINETS AND RACKS SHALL BE PROVISIONED

AS DEPICTED IN DRAWINGS (NOTES 1-4). ALL

OTHER ELECTRONIC EQUIPMENT SHALL BE

CUSTOMER PROVIDED.

NOTE 7: PROVIDE TWO (2) DEDICATED ELECTRICAL POWER

CIRCUITS PER EACH RACK AND CABINET, EACH

CIRCUIT WITH A DEDICATED CIRCUIT BREAKER.

NOTE 8: 4 RMU FIBER OPTIC COMBINATION UNIT WITH

EIGHT (8) SINGLE MOCE SC CONNECTOR PANELS

AND FOUR (4) BLANK PANELS FOR CCTV. PROVIDE

TWENTY-FOUR (24) SINGLE MODE PATCH

(3 PER CONNECTOR PANEL) 0CORDS SC-SC.

FSV-1 48SM, FSV-2 6SM, FSV-3 18SM.

NOTE 9: CONTRACTROR SHALL PROVIDE ALL EQUIPMENT

NECESSARY TO PROVIDE A FUNCTIONING CCTV

SYSTEM.

NOTE 10: COPPER CABLING SHALL BE PROVIDED BY THE

CONTRACTOR IN ORDER TO CONNECT THE PET[S]

TO VOICE PATCH PANELS IN THE VOICE CABINET.

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

S U

BM

IT

T E D

B Y:

S

IZ

E:

FI

LE

N

O

IS

SU

E D

A T E:

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C

KD

B Y:

US Army Corps of Engineers ®

X

A

P

LO

T

SC

AL

E:

P

LO

T D

A T E:

SHEET OF

US

A rm y

Co rp s of

E ng in ee rs M id dl e Ea st D is tri ct

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

B

C

D

2 3 4 5 8/

/2

9:

:0

A M

8/

/2

9:

:0

AM

U N

SP

E C

IF

IE

D W

O R

L D W

ID

E

A

IR

D

EF

EN

SE

IM

PR

O V E

M

EN

TS

-0 7-

- C O

N

TR

AC

T

N U

M

BE

R

Middle East District

D I

D I

D

AV

E S

. C

LA

R

KE

A-

TN

2D T0

T-502

W

IN

C H

E

ST

E R

, V A

C H

TE

LE

C O

M R

M

C

A B

IN

ET

R

A C

K D

ET

AI

LS

S I

TE

A

P2 -4

EN

G

A G

EM

EN

T C

O

NT

RO

L

ST

A

TI

O

N

COMM RM 108 CABINET & RACK DETAILS - SITE 6

M

AR

K D

ES

C

R

IP

TI

O

N D

A

TE

A P

PR

A M

E N

D M

EN

T

#3

/2 5/

A

M E

N D

M

EN

T #6

/1

8/

NOT TO SCALE

SHEET NOTES:

NOTE 7: COPPER CABLING SHALL BE PROVIDED BY THE

CONTRACTOR IN ORDER TO CONNECT THE PET[s]

TO VOICE PATCH PANELS IN THE VOICE CABINET.

FIN. FLOOR

T.O.P

T.O. BEAM

ABCEFGHI D

B-B

A-301

LECTURE HALL

ENTRY

COMM

ELEC.

TOILET

114A

OFFICE

OFFICE SUITE

FIN. FLOOR

T.O.P

T.O. BEAM

2 3 5 6 7 8 941-41-31-21-1 10A-A A-301

STORAGE

CORR.

KITCHEN

LECTURE HALL

SECURITY

106D

FIN. FLOOR

T.O.P

TOF

-1075

T.O. BEAM

9 10

METAL PANEL SOFFIT

LIGHTS SEE ELECTRICAL

COLUMN BEYOND

STOREFRONT

A-301

1 TYP

A-301

2 TYP

CANT

TIE BACK COPING ANCHOR

SLOPE

50MM CONCRETE PAVERS

STONE BALLAST- FULL

COVER AROUND PERIMETER

TOO SMALL FOR PAVERS

TPO 80MIL ROOF MEMBRANE

SYSTEM, PER MANUFACTURERS

SPECIFICATIONS

MANUFACTURER'S

STANDARD FASTENING

PLATE AND SCREWS

FLEXIBLE EXTERIOR

SEALANT

PRE-CAST

CONC. CAP

DRIP EDGE

SPRAY-APPLIED

AIR/VAPOR BARRIER

EIFS SYSTEM

STUCCO FINISH

BLOCKING,

2x12

TPO 80MIL ROOF

MEMBRANE

SYSTEM, PER

MANUFACTURERS

SPECIFICATIONS

SELANT

PRE WRAPPED BASE

INSULATIN BOARD

PER MFR STANDARD

CANT

TIE BACK COPING ANCHOR

SLOPE

50MM CONCRETE PAVERS

STONE BALLAST- FULL

COVER AROUND PERIMETER

TOO SMALL FOR PAVERS

TPO 80MIL ROOF MEMBRANE

SYSTEM, PER MANUFACTURERS

SPECIFICATIONS

MANUFACTURER'S

STANDARD FASTENING

PLATE AND SCREWS

FLEXIBLE EXTERIOR

SEALANT

PRE-CAST

CONC. CAP

DRIP EDGE

SPRAY-APPLIED

AIR/VAPOR BARRIER

EIFS SYSTEM

STUCCO FINISH

BLOCKING,

2x12 & 2x6

3000 mm

METAL REVEAL

METAL PANEL SOFFIT

5050 65

SOFFIT ASSEMBLY SHALL BE PREFINISHED

METAL SUPPORTED BY METAL FRAMING PER

STRUCTURAL REQUIREMENTS. SOFFIT

PANELS SHALL BE CONSISTENT OTHER

METAL WALL/SOFFIT PANELS USED ON PEMB

IN THIS PROJECT. CONCEAL ALL FASTENERS

AND COLOR SHALL BE WHITE.

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

S U

BM

IT

T E D

B Y:

S

IZ

E:

FI

LE

N

O

IS

SU

E D

A T E:

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C

KD

B Y:

US Army Corps of Engineers ®

X

A

P

LO

T

SC

AL

E:

P

LO

T D

A T E:

US

A rm y

Co rp s of

E ng in ee rs M id dl e Ea st D is tri ct

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

B

C

D

2 3 4 5 8/

/2

:5

7:

P M

8/

/2

:5 7:

P

M

U N

SP

E C

IF

IE

D W

O R

L D W

ID

E

A

IR

D

EF

EN

SE

IM

PR

O V E

M

EN

TS

-0 7-

- C O

N

TR

AC

T

N U

M

BE

R

Middle East District

G

AR

Y D

. B

AK

ER

, R

.A

R

ST

JE

FF

ER

Y

P . R

AN

EY

, C H

IE

F

A C

H

IT

EC

TU

R

AL

B R

AN

C

H

B

-A E

1S

E0

A-301

W

IN

C H

E

ST

E R

, V A

JP

R

SE

C

TI

O

N S-

S

IT

E

- A

LJ

B

P2 -4

H

EA

DQ

UA

R

TE

RS

B

U I

LD

IN

G

1 : 100A-101

A-A BUILDING SECTION A-A (SITE 6 - ALJ)

1 : 100A-101

B-B BUILDING SECTION B-B (SITE 6 - ALJ)

1:100

10m2m 8m6m4m0m

GENERAL NOTES:

1. REFER TO SHEET SA-519 FOR TYPICAL WALL SECTIONS.

1 : 50A-101

C-C CANOPY SECTION (SITE 6 - ALJ) 1:50

5m1m 4m3m2m0m

1:10

1m0.2m 0.8m0.6m0.4m0m

1 : 10

EFIS CANOPY DETAIL (SITE 6 - ALJ)

1 : 10

EFIS DETAILS (SITE 6 - ALJ)

M

AR

K D

ES

C

R

IP

TI

O

N D

A

TE

A P

PR

A M

E N

D M

EN

T

#6

/1 8/

SECURE VOICE

EQUIPMENT

RACK

VOICE/DATA

EQUIPMENT

RACK

CUSTOMER

USE

EQUIPMENT

RACK #2

CUSTOMER

USE

EQUIPMENT

RACK #1

OSP / FIBER

EQUIPMENT

RACK

48ST SM

FEED

2 - 100 PR PETs

DISTRIBUTION

(STACKED)

P E T

COAXIAL CABLE

SWING-DOWN RACK

(NOT TO SCALE)

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

S U

BM

IT

T E D

B Y:

S

IZ

E:

FI

LE

N

O

IS

SU

E D

A T E:

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C

KD

B Y:

US Army Corps of Engineers ®

X

A

P

LO

T

SC

AL

E:

P

LO

T D

A T E:

US

A rm y

Co rp s of

E ng in ee rs M id dl e Ea st D is tri ct

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

B

C

D

2 3 4 5 8/

/2

1:

:4

P M

8/

/2

1:

:4

PM

U N

SP

E C

IF

IE

D W

O R

L D W

ID

E

A

IR

D

EF

EN

SE

IM

PR

O V E

M

EN

TS

-0 7-

- C O

N

TR

AC

T

N U

M

BE

R

Middle East District

D I

D I

D

AV

E S

. C

LA

R

KE

B-

TN

1L S

T-401

W

IN

C H

E

ST

E R

, V A

C H

EN

LA

R G

ED

T

EL

EC

O M

R M

SI

TE

B

P2 -4

H

EA

DQ

UA

R

TE

RS

B

U I

LD

IN

G

NOTE 1: STANDARD CABLE LADDER SHALL BE 300mm WIDTH X 100 HEIGHT PLACED AT 3050mm AFF (ABOVE

FINISHED FLOOR).

NOTE 2: SECURE VOICE CABLE PDS SHALL BE 86mm WIDTH X 152mm HEIGHT PLACED AT 2850 AFF.

NOTE 3: A TOTAL OF TEN (10) - 100mm CONDUIT STUB-

UPS EXTEND TO MH-1. MH-1 SHALL HAVE 3 X 3 AND 2 X 2

DUCT WINDOWS CONNECTING TO THE HQ BLDG (SEE XT-

513).

NOTES

1 : 20T-101

1 CABLE LADDER PLAN - COMM RM 119 - SITE 6

1 : 20

COMMUNICATIONS ROOM LAYOUT AND RACK PLAN - COMM RM 119 - SITE 6

10 - 100mm CONDUIT

STUB-UPS

SECURE VOICE

PDS

CABLE TRAY

TMGB

M

AR

K D

ES

C

R

IP

TI

O

N D

A

TE

A P

PR

A M

E N

D M

EN

T

#3

/2 5/

A

M E

N D

M

EN

T #4

/0

2/

A M

E N

D M

EN

T

#6

/1 8/

1:20

2m0.4m 1.6m1.2m0.8m0m

NOTE 4: COPPER CABLING SHALL BE PROVIDED BY THE

CONTRACTOR IN ORDER TO CONNECT THE 100 PAIR PET

TO VOICE PATCH PANELS IN THE VOICE CABINET.

NOTE 5: CCTV EQUIPMENT AND CABLING DETAILS ARE

PROVIDED IN SHEET B T-501.

NOTE 1: 2 RMU HORIZONTAL CABLE MANAGEMENT BAR

NOTE 2: 4 RMU FIBER OPTIC COMBINATION UNIT WITH

EIGHT (8) SINGLE MOCE SC CONNECTOR PANELS

AND TWO (2) BLANK PANELS. PROVIDE NINETY-SIX

(96) SINGLE MODE PATCH CORDS SC-SC.

FCOMM 48SM, FCM 48SM.

NOTE 3: 48 PORT, CATEGORY 6, UTP PATCH PANEL.

PROVIDE FORTY-EIGHT (48) CATEGORY 6 GREEN

PATCH CORDS, RJ45-RJ45.

NOTE 4: 4 RMU FIBER OPTIC COMBINATION UNIT WITH

TWO (2) SINGLE MOCE SC CONNECTOR PANELS

AND TEN (10) BLANK PANELS. PROVIDE TWENTY-

FOUR (24) SINGLE MODE PATCH CORDS SC-SC.

NOTE 5: 24 PORT, CATEGORY 6, UTP PATCH PANEL.

PROVIDE TWENTY-FOUR (24) CATEGORY 6 GREEN

PATCH CORDS, RJ45-RJ45.

NOTE 6: CABINETS AND RACKS SHALL BE PROVISIONED

AS DEPICTED IN DRAWINGS (NOTES 1-4). ALL

OTHER ELECTRONIC EQUIPMENT SHALL BE

CUSTOMER PROVIDED.

NOTE 7: PROVIDE TWO (2) DEDICATED ELECTRICAL POWER

CIRCUITS PER EACH RACK AND CABINET, EACH

CIRCUIT WITH A DEDICATED CIRCUIT BREAKER.

NOTE 8: 4 RMU FIBER OPTIC COMBINATION UNIT WITH

EIGHT (8) SINGLE MOCE SC CONNECTOR PANELS

AND FOUR (4) BLANK PANELS. PROVIDE TWENTY-FOUR

(24) SINGLE MODE PATCH (3 PER CONNECTOR PANEL)

CORDS SC-SC. FSV-1 48SM, FSV-2 6SM, FSV-3 18SM.

NOTE 9: CONTRACTROR SHALL PROVIDE ALL EQUIPMENT

NECESSARY TO PROVIDE A FUNCTIONING CCTV

SYSTEM.

NOTE 10: COPPER CABLING SHALL BE PROVIDED BY THE

CONTRACTOR IN ORDER TO CONNECT THE PET[S]

TO VOICE PATCH PANELS IN THE VOICE CABINET.

VOICE / DATA

EQUIPMENT RACK

SECURE VOICE

EQUIPMENT RACK

NOTE 1

NOTE 1

NOTE 1

NOTE 4

NOTE 5

CUSTOMER USE

EQUIPMNET RACK 1

NOTE 1

NOTE 1

NOTE 3

NOTE 1

NOTE 2

NOTE 3

NOTE 1

24 STRAND, SM FOC

TO COMM RM 106E.

OSP /FIBER

EQUIPMENT RACK CUSTOMER USE

EQUIPMNET RACK 2

48 STRAND, OSP SINGLE MODE FIBER

TO ECS BLDG COMM RM - FCOMM

24 STRAND, SINGLE MODE OSP FIBER OPTIC

CABLE TO ECS BLDG SECURE VOICE

EQUIPMENT RACK - FSV

48 STRAND, SM FOC

FCM 1, 1-48, 48SM

6 STRAND, SM FOC

FCM-2, 19-24, 24SM

18 STRAND, SM FOC

FCM-3, 1-18, 18SM

NOTE 8

NOTE 1

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

S U

BM

IT

T E D

B Y:

S

IZ

E:

FI

LE

N

O

IS

SU

E D

A T E:

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C

KD

B Y:

US Army Corps of Engineers ®

X

A

P

LO

T

SC

AL

E:

P

LO

T D

A T E:

US

A rm y

Co rp s of

E ng in ee rs M id dl e Ea st D is tri ct

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

B

C

D

2 3 4 5 8/

/2

1:

:3

P M

8/

/2

1:

:3

PM

U N

SP

E C

IF

IE

D W

O R

L D W

ID

E

A

IR

D

EF

EN

SE

IM

PR

O V E

M

EN

TS

-0 7-

- C O

N

TR

AC

T

N U

M

BE

R

Middle East District

C H

D I

D

AV

E S

. C

LA

R

KE

B-

TN

1D T0

T-501

W

IN

C H

E

ST

E R

, V A

D I

C O

M M

R A

C K

D

ET

A

IL

S

IT

E

B

P2 -4

H

EA

DQ

UA

R

TE

RS

B

U I

LD

IN

G

SHEET NOTES

NOT TO SCALE

NOT TO SCALE

COMM RM 119 RACK DETAILS - SITE 6

M

AR

K D

ES

C

R

IP

TI

O

N D

A

TE

A P

PR

A M

E N

D M

EN

T

#3

/2 5/

A

M E

N D

M

EN

T #6

/1

8/

DOOR NOTES:

1. SEE SHEET SA-506 FOR DOOR & FRAME TYPES.

ABBREVIATIONS:

HMD-E HOLLOW METAL DOOR - EXTERIOR

STL STEEL

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

S U

BM

IT

T E D

B Y:

S

IZ

E:

FI

LE

N

O

IS

SU

E D

A T E:

C O

N

TR

A C

T N

O

S O

LI

C

IT

A

TI

O

N N

O

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C

KD

B Y:

US Army Corps of Engineers ®

X

A

P

LO

T

SC

AL

E:

P

LO

T D

A T E:

SHEET OF

US

A rm y

Co rp s of

E ng in ee rs M id dl e Ea st D is tri ct

UNLESS OTHERWISE NOTED, LINEAR

DIMENSIONS SHOWN ARE IN MILLIMETERS.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

B

C

D

2 3 4 5 8/

/2

2:

:2

P M

8/

/2

2:

:2

PM

U N

SP

E C

IF

IE

D W

O R

L D W

ID

E

A

IR

D

EF

EN

SE

IM

PR

O V E

M

EN

TS

-0 7-

- C O

N

TR

AC

T

N U

M

BE

R

Middle East District

S

FJ

/S

FL

S

FJ

/S

FL

JE

FF

R E

Y P

. R A

N E

Y C hi ef

, B ld g.

D es ig n S ec tio n

L-

A E

1S

C

A-601

W

IN

C H

E

ST

E R

, V A

S

FJ

/S

FL

D O

O R

F

IN

IS

H S

C H

E D

UL

ES

L

P2 -4

PO

W

ER

P

LA

NT

F A

C

IL

IT

Y

1:

DOOR SCHEDULE

Door Number Type

DOOR

Fire

Rating

FRAME

Hardware Comments

SIZE

Material Finish Type Material Finish

DETAILS

Width Height Thickness Head Jamb SILL 102 DF 1800 2150 50 HMD-E PAINT F2 STL PAINT 1/SA-508 2/SA-508 3/SA-508 6 SECURE DOOR - IDS 103 DF 1800 2150 50 HMD-E PAINT F2 STL PAINT 1/SA-508 2/SA-508 3/SA-508 6 SECURE DOOR - IDS

FINISH SCHEDULE

ROOM

NO

ROOM

NAME Area

WALL FINISH FLOOR CEILING NOTES &

REMARKSNORTH EAST SOUTH WEST MAT. FIN. MAT. FIN.

101 GENERATORS 161.6 m² PAINT THROUGHOUT, ALL

SURFACES

PAINT, THROUGHOUT, ALL

SURFACES

PAINT, THROUGHOUT, ALL

SURFACES

PAINT, THROUGHOUT, ALL

SURFACES

CONC EPOXY METAL PAINT PRE-ENG. SUNSHADE

OVER AREA

102 ELECTRICAL 86.9 m² PLASTER,PAINT

THROUGHOUT, ALL SURFACES

PLASTER, PAINT,

THROUGHOUT, ALL SURFACES

PLASTER, PAINT,

THROUGHOUT, ALL SURFACES

PLASTER, PAINT,

THROUGHOUT, ALL SURFACES

CONC EPOXY CONC PAINT

103 FUTURE SUB

STATION

35.4 m² PLASTER,PAINT

THROUGHOUT, ALL SURFACES

PLASTER, PAINT,

THROUGHOUT, ALL SURFACES

PLASTER, PAINT,

THROUGHOUT, ALL SURFACES

PLASTER, PAINT,

THROUGHOUT, ALL SURFACES

CONC EPOXY CONC PAINT

M

AR

K D

ES

C

R

IP

TI

O

N D

A

TE

A P

PR

A M

E N

D M

EN

T

#6

/1 2/

Sheets
G-012 - INDEX OF DRAWINGS VOLUME 2 SHEET 1
G-013.pdf
Sheets
G-013 - INDEX OF DRAWINGS VOLUME 2 SHEET 2
443309-SITE06--XE101PN06.pdf
443309-SITE06--XE101PN06
References
443309-SITE06--XE101PN06.dgn, Model
PW_WORKDIR:d0551988
443309--CS101-6PN.dgn, Model
443309-SITE06--XE102PN06.pdf
443309-SITE06--XE102PN06
References
Ref, 443309-SITE06--XE102PN06.dgn, Model
443309-SITE06--XT601DI06.pdf
443309-SITE06--XT601DI06
443309A-A-301.pdf
Sheets
A-301 - SECTIONS- SITE 06- ALJ
443309A-T50106_n0enedbi.pdf
Sheets
T-502 - TELECOM RM 108 CABINET & RACK DETAILS - SITE 6
443309A-T50206_n0enedbi.pdf
Sheets
T-502 - TELECOM RM 108 CABINET & RACK DETAILS - SITE 6
443309A-T51106_n0enedbi.pdf
Sheets
T-511 - TELECOM RM 108 ENLARGED FLOOR PLAN - SITE 7
443309B-T40106_n0enedbi.pdf
Sheets
T-401 - ENLARGED TELECOM RM 119 - SITE 6
443309B-T50106_n0enedbi.pdf
Sheets
T-501 - COMM RACK DETAIL SITE 6
443309L - POWER PLANT FACILITY05.pdf
Sheets
A-601 - DOOR & FINISH SCHEDULES

File details come from the government source that posted it. Updated .