This document package includes technical construction drawings and details for the renovation of Lincoln Hall Building 607 at the United States Military Academy in West Point, New York, as well as the corresponding solicitation for the construction contract. The drawings show rebar tension development lengths, schedules for post-installed anchors in concrete and masonry, details for steel beam splices, connections to existing structures, bearing conditions, and slab edge conditions. The solicitation is for a firm-fixed price construction contract to complete the renovation of the building according to the drawings. The U.S. Army Corps of Engineers, New York District is seeking proposals for the project on a best value tradeoff basis. Proposals are due by the date specified in the solicitation number provided.
View the file
Other files for this federal contract opportunity
Show all 42
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REBAR TENSION DEVELOPMENT LENGTHS (INCHES)
BAR SIZE CASE 1
#3
#4
#5
#6 50
#7 7248
#8
#9
#10
#11
CASE 2
NOTES:
1. CASE 1 IS DEFINED AS BARS WITH CLEAR SPACING OF AT LEAST 2 x db AND WITH
CLEAR COVER AT LEAST db.
2. CASE 2 IS DEFINED AS BARS THAT DO NOT SATIFY THE REQUIREMENTS OF CASE 1.
3. FOR BARS CAST WITH 12" OR MORE OF FRESH CONCRETE BELOW, MULTIPLY THE
VALUES BY 1.3.
4. FOR LAP SPLICES, MULTIPLY THE VALUES BY 1.3.
5. FOR LIGHTWEIGHT CONCRETE, MULTIPY THE VALUES BY 1.34.
NOTES:
1. MINIMUM EFFECTIVE EMBEDMENT IS APPLIED TO POST INSTALLED ANCHORS UNLESS
OTHERWSE NOTED IN THE DETAIL.
2. REQUIRED SHEAR CAPACITY IS AN UNFACTORED LOAD.
POST-INSTALLED ANCHOR SCHEDULE
ANCHORING TO NORMAL CONCRETE
ANCHOR TYPE
BASIS OF DESIGN
EXPANSION ANCHOR
ANCHOR DIAMETER MIN EFFECTIVE
EMBEDMENT, UON
5/8" 3/4"
ANCHORING TO BRICK OR STONE MASONRY
ANCHOR TYPE
BASIS OF DESIGN
ANCHOR DIAMETER MIN EFFECTIVE
EMBEDMENT, UON
4" 4 3/4"
ADHESIVE ANCHOR
REQUIRED SHEAR
CAPACITY (KIP)
REQUIRED SHEAR
CAPACITY (LBS)
13.9 10.5
ADHESIVE ANCHOR
1/2" 2 3/4" 5.3
5/8" 3/4"
6" 6" 1.7
1/2" 3 1/4" 6.9
1.2
3/4" 4" 9.5
NOTES:
1. SEE GENERAL NOTES FOR CONNECTION DESIGN REQUIREMENTS.
2. SPLICE IS TO BE USED IF NECESSARY FOR CONSTRUCTABILITY.
ENSURE THERE IS A
GAP BETWEEN BEAM
AND EXISTING SLAB
EXISTING SLAB
BEAM, SEE PLAN
5/16 33
TYP. EACH
SIDE T&B
14" WIDE, 3/4" THK, 5'-6"
LONG FLANGE PLATE
TOP AND BOT
SHEAR CONN DELEGATED.
REF STRUCTURAL STEEL
SECTION IN GENERAL
NOTES.
5' - 6"
EXISTING SLAB
NOTES:
1. EXISTING STEEL MEMBER MAY NOT BE WELDABLE.
BOLT ANGLE TO EXISTING WIDE FLANGE MEMBER.
EXISTING WIDE
FLANGE MEMBER
SHEAR CONN DELEGATED. BOLT TO
EXISTING BEAM. REF STRUCTURAL
STEEL SECTION IN GENERAL NOTES.
BEAM, SEE PLAN
BEAM, SEE PLAN
BEAM, SEEM PLAN
COPE BEAM AS REQUIRED
NOTES:
1. SEE GENERAL NOTES FOR CONNECTION DESIGN
REQUIREMENTS
EXISTING SLAB
DRYPACK ABOVE
BEAMS SPANNING
BETWEEN EXTERIOR
WALL AND CORRIDOR
WALL
1/4 12
1/4 12TYP. EACH
SIDE OF
BEAM FLANGE PLATE
1/4
TYP. EACH
SIDE.
1/4 12
1/4 12TYP. EACH
SIDE OF
BEAM
14" WIDE, 1/2" THK FLANGE
PLATE
SHEAR CONN DELEGATED.
REF STRUCTURAL STEEL
SECTION IN GENERAL
NOTES.
MIN 1'' GROUT
PL1/2x4x0'-6"
MAX THROUGH POCKET
SIZE = BEAM DEPTH + 4'' x
FLANGE WIDTH + 4''
STRENGTHENING
STEEL BEAM
FILL POCKET WITH GROUT
OR DRY PACK
EXISTING SLAB
2" 4"
MECHAINCAL SHAFT
WALL
MECHAINCAL SHAFT
WALL
FILL WITH GROUT AFTER
INSTALLING BEAM.
STEEL BEAM
PL3/8 WITH TWO 1/2"
DIAMETER, 8" LONG
HEADED STUDS, SPACED
6" APART.
8 INCH HIGH, 4'-0" LONG
(MIN) BOND BEAM.
5" MIN BEARING
GROUT CELLS UNDER
STEEL BEAM SOLID TO A
DEPTH OF AT LEAST 24"
BELOW THE BEAM.
3" M
AX
G
R O
U T.
C U
T
BL
O C
K
BE
LO
W
B O
N D
BE
AM
A
S R
EQ
U
IR
ED
1/4 3
2 1/4"
2"
2 1/4"
2"
SECTION
PLAN VIEW OF
BEARING PLATE
SCHEDULED ELEVATOR SHAFT
MASONRY WALL
EXISTING CONCRETE SLAB
DRY PACK ANY GAP BETWEEN TOP OF
MASONRY WALL AND BOTTOM OF RIBS OF
EXISTING CONCRETE SLAB.
DEMOLISH FINISHES SO THAT MASONRY
WALL BEARS ON EXISTING CONCRETE SLAB.
BOND BEAM
SOLID MASONRY UNITS
AT AREAS BETWEEN EXISTING CONCRETE
RIBS, INFILL OPEN CLAY TILE VOIDS WITH
DRYPACK.
CUT FOR OPENING LEAVES AT LEAST 4" OF EXISTING RIB
NOTE:
1) THE POSITION OF THE RIBS IN RELATION TO THE OPENING IS UNKNOWN.
TREAT THE EDGE OF THE OPENING AS SHOWN FOR THE CASES ABOVE.
STEP 1
STEP 2
STEP 1
STEP 2
OPENING OPENING
OPENING OPENING
STEP 1
STEP 2
OTHER CASES
OPENING
OPENING
CUT FOR OPENING LEAVES LESS THAN 4" OF EXISTING RIB
DRYPACK DRYPACK
DRYPACK
4" MIN
SOLID MASONRY UNITS SOLID MASONRY UNITS
SOLID MASONRY UNITS
SUBDRAINAGE PIPE (NOTE 3)
SLAB-ON-GRADE
6" CAPILLARY WATER BARRIER
M
IN
1'
0"
FILTER MATERIAL (NOTE 1)
PERMEABLE GEOTEXTILE
FABRIC (NOTE 2)
NOTES:
1. FILTER MATERIAL MUST SATISFY THE REQUIREMENTS OF AASHTO SIZE NO. 7.
2. PERMEABLE GEOTEXTILE FABRIC SHOULD HAVE AN EQUIVALENT OPENING SIZE
NOT GREATER THAN THE NO. 70 U.S. STANDARD SIEVE SIZE.
3. SUBDRAINAGE PIPING MUST BE 4 INCH DIAMETER, SLOTTED, CORRUGATED
POLYETHYLENE TUBING IN ACCORDANCE WITH ASTM F104 WITH A MAXIMUM 1/8
SLOT WIDTH.
6" MIN BOTTOM AND
SIDES. 2" MIN TOP.
ADHESIVE ANCHORS
REFER TO EQUIP
SHOP DRAWINGS
FOR TYPE, SIZE,
PROJECTION AND
LOCATION
MIN 3" EMBED INTO
SLAB
ROUGHEN TO 1/4" AMPLITUDE &
APPLY BONDING AGENT
T/EX SLAB EL
TY
P
1/
2" C
LR
SEE NOTE BELOW
MIN
6"
#3 @ 12" OC
NOTE: COORDINATE PAD LOCATIONS AND SIZE WITH ELECTRICAL &
MECHANICAL DRAWINGS AND EQUIP MANUFACTURER'S
RECOMMENDATIONS
3/4" CHAMFER TYP
SEE PLAN
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
S-502
TY
PI
C
AL
D
ET
AI
LS
D
EV
EL
O
PM
EN
T
LE
N
G
TH
S, P
O
ST
-IN
ST
AL
LE
D A
N C
H O
R S, ST
EE
L
BE
AM
S
BU
IL
D
IN
G S
5/
R
EN
O
VA
TI
O
N
LI
N
C O
LN
H
AL
L
LI
N
C O
LN
H
AL
L
W
ES
T
PO
IN
T, N
EW
Y O
R K
B.
B
AU
M
ST
AR
K
J.
G
AL
LA
G H
ER
K.
L
EI
BO
W
IT
Z
M
AR
C
H
W
2D S-
-R
-0
W
2D S-
-C
-0
1- L
REVISED RTA SUBMISSION 3/1/2023
NTSA5 TENSION DEVELOPMENT LENGTHS
NTSA3 POST-INSTALLED ANCHOR SCHEDULE
3/4" = 1'-0"B1 BEAM SPLICE - TYPICAL
3/4" = 1'-0"C1 BEAM TO EXISTING GIRDER - TYPICAL
3/4" = 1'-0"B2 STEEL MOMENT CONNECTION - TYPICAL
3/4" = 1'-0"A2
STEEL BEAM BEARING ON
MECHANICAL SHAFT WALL
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
IS
SU
ED
V
IA
A M
EN
D
M
EN
T 6 /
/2
1" = 1'-0"C2 STEEL BEAM BEARING ON MASONRY - TYPICAL
3/4" = 1'-0"B3 SLAB OPENING - WALL PERPENDICULAR TO SLAB
3/4" = 1'-0"C3 SLAB OPENING - WALL PARALLEL TO SLAB
3/4" = 1'-0"D1
SLAB-ON-GRADE UNDERSLAB
DRAINAGE
NTSB5 EQUIPMENT PAD
| Sheets |
| S-502 - TYPICAL DETAILS - DEVELOPMENT LENGTHS, POST-INSTALLED ANCHORS, STEEL BEAMS |