Lincoln Hall Drawing Changes 22 JUN 2023.pdf

PDF 23 MB Posted

Attached to
LINCOLN HALL RENOVATION, BLDG. 607 Federal contract opportunity
Solicitation number
W912DS23R0009
Issued by
Department of the Army Corps of Engineers Engineering District New York

About this file

This document provides details on a federal solicitation to renovate Building 607, Lincoln Hall. The U.S. Army Corps of Engineers, New York District is seeking a firm-fixed price contract through an unrestricted Best Value Trade Off procurement process via solicitation number W912DS23R0009. The solicitation is for renovation work to Lincoln Hall, including supporting tasks. Responses are due through the Request for Proposal. The agency listed is the Department of the Army Corps of Engineers Engineering District New York.

View the file

Other files for this federal contract opportunity

Other files attached to LINCOLN HALL RENOVATION, BLDG. 607, newest first.
File Type Posted
W912DS23R0009-0005.pdf PDF
Amendment 0004.pdf PDF
I-603 - FINISH MATERIAL SCHEDULE.pdf PDF
I-604 - FINISH MATERIAL SCHEDULE.pdf PDF
S-502.pdf PDF
A-202.pdf PDF
A-204.pdf PDF
A-401.pdf PDF
A-562 - MILLWORK DETAILS - BRIEFING ROOM.pdf PDF
Supplmental laydown area at Ordnance road.pptx PPTX presentation
A-429 - ENLARGED BRIEFING ROOM PLANS AND ELEVATIONS.pdf PDF
I-103 - LEVEL B1 FLOOR PLAN - FINISH.pdf PDF
I-602 - FINISH MATERIAL SCHEDULE.pdf PDF
L-502.pdf PDF
Amendment 0003.pdf PDF
Amendment 0002.pdf PDF
21 30 00-001.2_R3 Fire Pump House Submittal (Cullum).pdf PDF
Lincoln Hall Specification Changes 22 JUN 2023.pdf PDF
C-001.pdf PDF
W912DS23R0009 0001.pdf PDF
CD101.pdf PDF
CS103.pdf PDF
2023.06.20 Lincoln Hall site walk through sign in sheet.pdf PDF
AS BUILT DRAWING 1A - Approximate Location of Knox BatteryAmend 1.pdf PDF
LH- H-101.pdf PDF
W912DS23R0009.pdf PDF
JA 006-23 Belden Brick.pdf PDF
JA 008-23-Ruabon Quarry Tile.pdf PDF
JA 010-23 Best Hardware Lock Cylinders and Cores.pdf PDF
Vol 1 WP Lincoln Hall Revised RTA Specifications 1 MAR 2023.pdf PDF
LH_VOLUME 03_Revised_RTA_2023-03-01.pdf PDF
Vol 2 WP Lincoln Hall Revised RTA Specifications 1 MAR 2023.pdf PDF
Vol 3 WP Lincoln Hall Revised RTA Specifications 1 MAR 2023.pdf PDF
LH_VOLUME 01_Revised_RTA_2023-03-01.pdf PDF
LH_VOLUME 04_Revised_RTA_2023-03-01.pdf PDF
JA 007-23 Distributed Antenna System.pdf PDF
JA 013-23 Monaco.pdf PDF
LH_VOLUME 02_Revised_RTA_2023-03-01.pdf PDF
JA 009-23 Avaya Switch.pdf PDF
JA 011-23 Ventrol AHU.pdf PDF
JA 012-23 Identiv Card Access System.pdf PDF
JA 014-23 Shark Meter.pdf PDF
Show all 42

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

W X

W10X88*

W X

W10X88*

W X

W10X88*

W X

W10X88*W10X88*

W X

W10X88*

W X

W10X88*

B1

S-401

B4

S-401

B5

S-401

B3

S-502

SIM

B3

S-401

INFILL EXISTING OPENING IN

CORRIDOR WALL (TYP). SEE

TYPICAL DETAILS.

A4

S-402

S .5

D1.5+3.25

STRENGTHENING STEEL BEAM (TYP).

SEE TYPICAL DETAILS.

B1

S-402

B2

S-402

B3

S-402

A1

S-402

MW6

D .5

.2

D .0

.2

D .0

.2

SOG 6

W8X15*

D .5

.2

A4

S-503

TYP

C5

S-401

C4

S-401

9' - 6"

9' - 6"

W8X15*

W8X15*

MW8

CONTRACTION JOINT

EXISTINGEXISTINGL1 L1L1L1

EXISTING

C2

S-402

L1

(2

L

L1

MECH UNIT MAX

WEIGHT: 11000 LBS

APPROXIMATE AREA TO BE REPLACED

AFTER EXCAVATION BENEATH SLAB-ON-

GRADE

D4

S-402

TYP

A4

S-404

W X

W X

W X

W8X15

SLAB-ON-GRADE SLAB-ON-GRADE

(E

S L A

B

SLAB-ON-GRADE

SLAB-ON-GRADE

(E

S L A

B

(E) SLAB

(E) SLAB

(E) SLAB

(E

S L A

B

(E

W B

E A

M

(E

W B

E A

M

(E

W B

E A

M

(E

W B

E A

M

(E) W BEAM

(E) W BEAM

(E

W B

E A

M

(E) W BEAM

EXISTING L3

APPROXIMATE AREA

TO BE REPLACED

AFTER EXCAVATION

BENEATH SLAB-ON-

GRADE

C1

S-502

TYP

SOME BEAMS REQUIRE

SPLICING FOR

INSTALLATION. REFER

TO TYPICAL DETAIL.

B1

S-502

TYP

W X

3" EQUIPMENT PAD.

PAD CAN BE PLACED

DIRECTLY ON THE

EXISTING

CEMENTITIOUS

FLOORING.

MECH UNIT MAX WEIGHT: 2500 LBS

3" EQUIPMENT PAD. PAD CAN BE

PLACED DIRECTLY ON THE

EXISTING CEMENTITIOUS

FLOORING.

A1

S-504

TYP

MW8

4' - 0"

1' - 0"

4"

W X

W X

W8X31*

W X

SEE FOR MECHANICAL

PLATFORM AREA PLAN.

/A1 S-102

H S

S X

X

/1

S-404

A3

SLAB EDGE TO BE

COORDINTED WITH

SELECTED LIFT.

REFER TO ARCH.

5' - 6"

3" EQUIPMENT PAD. PAD CAN BE

PLACED DIRECTLY ON THE

EXISTING CEMENTITIOUS

FLOORING. MAX EQUIPMENT

WEIGHT: 750 LBS.

CL NORTH

WING

CORRIDOR

16' - 4" 19' - 7"

4" 4"

4' - 2"

"7' - 10" 1' - 8"

W8X15*

1' - 6"

BC1

BC1

BC1

S-404

C4

CONCRETE WALL SCHEDULE

STEEL DECKING SCHEDULE SEE

CONCRETE SLAB-ON-GRADE SCHEDULE

CONCRETE ONE-WAY SLAB SCHEDULE

CONCRETE WALL FOOTING SCHEDULE

STEEL LINTEL SCHEDULE

MASONRY WALL SCHEDULE

BEAM CONNECTION PLATE

/B3 S-501 /A2 S-504 /D3 S-501 /A1 S-501 /A3 S-501

FOR SEE

/B2 S-504 /C3 S-501 /B1 S-505

21 3 54

B

A

C

D

E

D1

1' - 0"

/4

/2

/4

" W8X31 TYP.

EXISTING 10" FOUNDATION SLAB

KICKER BRACING

SEE /A3 S-103

FOR BASE CONNECTION

SEE /A2 S-505

2' - 6 1/2" 9' - 5 1/2" 12' - 9 3/4" 3' - 2 1/4"

NOTE: THE WORK DEPICTED ON THIS SHEET SHOULD

BE INCLUDED IN CLIN 005 FOR THE PRICE SCHEDULE.

N

8'4' 16'0

SCALE: 1/8"=1'-0"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

S-102

L E

V E

L B

F

L O

O R

P L A

N

B U

IL

D

IN

G

S

/6

R

E N

O V

A T

IO

N

L

IN

C O

L N

H A

L L

L

IN

C O

L N

H A

L L

W E

S T

P O

IN

T

N

E W

Y O

R K

B B

A U

M S

T A

R K

J G

A L L A

G H

E R

K L E

IB

O

W

IT

Z

M

A R

C H

W D

S -1

-R

-0

W D

S -1

-C

-0 -L

REVISED RTA SUBMISSION 3/1/2023

1/8" = 1'-0" C1

STRUCTURAL PLAN - LEVEL B2

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

IS

S U

E D

V

IA

A M

E N

D M

E N

T

/1 /2

3/16" = 1'-0" A1

MECHANCIAL PLATFORM - FOUNDATION PLAN

DRAWING ABBREVIATIONS

A ---------------------

A LABELCLASS A DOOR

A/C AIR CONDITION

A/C UNITAIR CONDITIONING UNIT

A/E ARCHITECT/ENGINEER

AB ANCHOR BOLT

ACC ACCESSIBLE

ACS AUTOMATIC CONTROL SYSTEM

ACS DR ACCESS DOOR

ACS PNLACCESS PANEL

ACT ACOUSTICAL CEILING TILE

ADA AMERICANS WITH DISABILITIES ACT

ADMIN ADMINISTRATION

AFC ABOVE FINISHED COUNTER

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AFS ABOVE FINISHED SLAB

AGGR AGGREGATE

AHU AIR HANDLING UNIT

AIB AIR INFILTRATION BARRIER

ALT ALTERNATE

ALUM ALUMINUM

ANOD ANODIZE

APC ACOUSTICAL PANEL CEILING

APPROX APPROXIMATE

AR AS REQUIRED

ARCH ARCHITECT

ASC ABOVE SUSPENDED CEILING

ASSY ASSEMBLY

ATC ACOUSTICAL TILE CEILING

AVG AVERAGE

AW ARCHITECTURAL WOODWORK

AWT ACOUSTICAL WALL TREATMENT

B ---------------------

B LABELCLASS B DOOR

BALC BALCONY

BB BASEBOARD

BC BOOKCASE

BD BOARD

BDRY BOUNDARY

BFF BELOW FINISH FLOOR

BHMA BUILDER'S HARDWARE MANUFACTURER'S

ASSOCIATION

BLDG BUILDING

BLKG BLOCKING

BLT IN BUILT-IN

BN BULLNOSE

BOS BOTTOM OF STEEL

BOT BOTTOM

BP BUILDING PAPER

BRKT BRACKET

BSMT BASEMENT

BTWN BETWEEN

BUR BUILT-UP ROOFING

C ---------------------

C CONC CAST CONCRETE

C LABELCLASS C DOOR

CAB CABINET

CATW CATWALK

CAV CAVITY

CBB CEMENTITIOUS (BACKER) BOARD

CD CONSTRUCTION DOCUMENTS

CDW CHILLED DRINKING WATER

CEM PLAS CEMENT PLASTER

CER CERAMIC

CF CONTRACTOR FURNISHED

CF/CI CONTRACTOR FURNISHED/CONTRACTOR

INSTALLED

CFE CONTRACTOR FURNISHED EQUIPMENT

CFLG COUNTERFLASHING

CFM CUBIC FEET PER MINUTE

CFMF COLD-FORMED METAL FRAMING

CFS CUBIC FEET PER SECOND

CG CORNER GUARD

CI CAST IRON

CIP CAST-IN-PLACE

CJ CONTROL JOINT

CL CENTER LINE

CLG CEILING

CLG DIFF CEILING DIFFUSER

CLG HT CEILING HEIGHT

CLL COLUMN LINE

CLO CLOSET

CLR COLOR

CLRM CLASSROOM

CMU CONCRETE MASONRY UNIT

CNDS CONDENSATE

CDR CARD READER

CO CLEANOUT

COL COLUMN

COMM COMMUNICATION

CONC CONCRETE

CONC FLR CONCRETE FLOOR

CONF CONFERENCE

CONT CONTINUE

COORD COORDINATE

CORR CORRIDOR

CP CONCRETE PIPE

CPT CARPET

CR CONTROL ROOM

CS CAST STONE

CSWK CASEWORK

CT CERAMIC TILE

CTB CERAMIC TILE BASE

CTF CERAMIC TILE FLOOR

CTR CENTER

CU FT CUBIC FEET

CW CASEMENT WINDOW

D ---------------------

D DEPTH

D LABELCLASS D DOOR

DBL DOUBLE

DEMO DEMOLITION

DEPT DEPARTMENT

DET DETAIL

DIA DIAMETER

DIR DIRECTION

DIST DISTANCE

DOC DOCUMENT

DR DOOR

DS DOWNSPOUT

E ---------------------

E LABEL CLASS E DOOR

EA EACH

EF EACH FACE

EIFS EXTERIOR INSULATION AND FINISH SYSTEM

EJ EXPANSION JOINT

ES EACH SIDE

EL ELEVATION

ELEV ELEVATOR

ENTR ENTRANCE

EPS EXPANDED POLYSTYRENE BOARD

(INSULATION)

EQ EQUAL

EWC ELECTRIC WATER COOLER

EXP EXPOSED

EXT EXTERIOR

EXT EXTINGUISHER

EXT GR EXTERIOR GRADE

GB GRAB BAR

GFCI GOVERNMENT FURNISHED CONTRACTOR

INSTALLED

GFGI GOVERNMENT INSTALLED FURNISHED

INSTALLED BY GOVERNMENT

GFRG GLASS-FIBER-REINFORCED GYPSUM

GLZ GLAZING

GR FL GROUND FLOOR

GUT GUTTER

GYP BD GYPSUM BOARD

GYP PLAS GYPSUM PLASTER

H -------------

HB HOSE BIBB

HDPE HIGH DENSITY POLYETHYLENE

HDW HARDWARE

HDWD HARDWOOD

HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)

HM HOLLOW METAL

HMD HOLLOW METAL DOOR

HORIZ HORIZONTAL

HT HEIGHT

HYDR HYDRAULIC

F ---------------------

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FAS BD FASCIA BOARD

FC BRK FACE BRICK

FCO FLOOR CLEANOUT

FD FLOOR DRAIN

FDTN FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FED FEDERAL

FF FINISH FACE

FF EL FINISH FLOOR ELEVATION

FF INSUL FOIL BACKED INSULATION

FGL FIBERGLASS

FH FIRE HOSE

FHP FULL HEIGHT PARTITION

FIN FINISH

FIN BS FINISH BOTH SIDES

FIN FLR FINISH FLOOR

FIN GR FINISH GRADE

FIXT FIXTURE

FLDG FOLDING

FLEX FLEXIBLE

FLG FLOORING

FLMT FLUSH MOUNT

FLR FLOOR

FM FACTORY MUTUAL

FOC FACE OF CONCRETE

FOM FACE OF MASONRY

FR FIRE RESISTANT

FRG FIBER REINFORCED GYPSUM

FRMG FRAMING

FRP FIBERGLASS REINFORCED PLASTIC

FRTW FIRE RETARDANT TREATED WOOD

FS FEDERAL SPECIFICATION

FSTNR FASTENER

FT FEET

FTG FOOTING

FWC FABRIC WALLCOVERING

G ---------------------

G NATURAL GAS

GALV GALVANIZED

GB GRAB BAR

GFCI GOVERNMENT FURNISHED CONTRACTOR

INSTALLED

GFGI GOVERNMENT INSTALLED FURNISHED

INSTALLED BY GOVERNMENT

GFRG GLASS-FIBER-REINFORCED GYPSUM

GLZ GLAZING

GR FL GROUND FLOOR

GUT GUTTER

GYP BD GYPSUM BOARD

GYP PLAS GYPSUM PLASTER

H ---------------------

HB HOSE BIBB

HDPE HIGH DENSITY POLYETHYLENE

HDW HARDWARE

HDWD HARDWOOD

HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)

HM HOLLOW METAL

HMD HOLLOW METAL DOOR

HORIZ HORIZONTAL

HT HEIGHT

HYDR HYDRAULIC

I ---------------------

IBC INTERNATIONAL BUILDING CODE

INSUL INSULATION

INT INTERIOR

ILO IN LIEU OF

J ---------------------

JAN JANITOR

K ---------------------

KPD KEYPAD

KIT KITCHEN

KPL KICKPLATE

L ---------------------

LAM LAMINATE

LAV LAVATORY

LBR LUMBER

LBS POUND

LDG LANDING

LF LINEAR FEET (FOOT)

LIB LIBRARY

LIN LINEAR

LKR LOCKER

LOC LOCATION

LT LIGHT

LVDR LOUVER DOOR

LVR LOUVER

M ---------------------

MACH RM MACHINE ROOM

MATL MATERIAL

MAX MAXIMUM

MC MOISTURE CONTENT

MD METAL DECK

MECH MECHANICAL

MECH RM MECHANICAL ROOM

MEMB MEMBRANE

MF MILL FINISH

MFR MANUFACTURER

MID MIDDLE

MIL STD MILITARY STANDARD

MIN MINIMUM, MINUTE

MIRR MIRROR

MISC MISCELLANEOUS

MLDG MOLDING (MOULDING)

MO MASONRY OPENING

MOD MODIFY

MB MOISTURE BARRIER

MTG MOUNTING

MTL METAL

MVBL MOVABLE

MWP MEMBRANE WATERPROOFING

N ---------------------

N NORTH

NA NOT APPLICABLE

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NP NO PAINT

NRC NOISE REDUCTION COEFFICIENT

NTS NOT TO SCALE

O -------------------

OA OVERALL

OC ON CENTER

OD OUTSIDE DIAMETER

OFD OVERFLOW DRAIN

OFF OFFICE

OGL OBSCURE GLASS

OPH OPPOSITE HAND

OPNG OPENING

OPP OPPOSITE

OPQ OPAQUE

OWSJ OPEN WEB STEEL JOIST

OPR OPERABLE

ORD OVERFLOW ROOF DRAIN

ORIG ORIGINAL

P --------------------

PA PUBLIC ADDRESS

PAR PARAPET

PAT PATTERN

PB PULL BOX

PBD PARTICLEBOARD

PCC PRECAST CONCRETE

PCF POUNDS PER CUBIC FOOT

PCT PERCENT

PERF PERFORATED

PERIM PERIMETER

PH PHASE

PIL PILASTER

PL PROPERTY LINE

PL GL PLATE GLASS

PLAM PLASTIC LAMINATE

PLAS PLASTER

PLBG PLUMBING

PLG PILING

PLYWD PLYWOOD

PNL PANEL

PP PL PUSH/PULL PLATE

PR PAIR

PRCST PRECAST

PRKG PARKING

PS CONC PRESTRESSED CONCRETE

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PRESSURE TREATED

PTD PAPER TOWEL DISPENSER

PTDR PAPER TOWEL DISPENSER AND

RECEPTACLE

PTN PARTITION

PWR POWER

Q --------------------

QT QUARRY TILE

QTY QUANTITY

R --------------------

RB RESILIENT BASE

RBM REINFORCED BRICK MASONRY

RBR RUBBER

RC REINFORCED CONCRETE

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

RDG INS RIGID INSULATION, SOLID

REC RECESSED

REC ROOM RECREATION ROOM

REF REFERENCE

REM REMOVABLE

REP REPAIR

REPL REPLACE

REQ REQUIRE

REQD REQUIRED

RESIL RESILIENT

REST RESTROOM

RF RESILIENT FLOORING

RFG ROOFING

RH ROOF HATCH

RHR RIGHT HAND REVERSE

RL ROOF LEADER

RLG RAILING

RM ROOM

RO ROUGH OPENING

RSD ROLLING STEEL DOOR

RV ROOF VENT

RVL REVEAL

S --------------------

SB SPLASH BLOCK

SCHED SCHEDULE

SD SMOKE DETECTOR

SF SQUARE FOOT (FEET)

SFTWD SOFTWOOD

SGL SINGLE

SHT MTL FLASH SHEET METAL (FLASHING)

SHTHG SHEATHING

SHV SHELVING

SIM SIMILAR

SJ SCORED JOINT

SKLT SKYLIGHT

SLNT SEALANT

SMK SMOKE

SMLS SEAMLESS

SP EL SPOT ELEVATION

SPEC SPECIFICATION

SQ SQUARE

SQ IN SQUARE INCH

SQ YD SQUARE YARD

SST STAINLESS STEEL

ST STAIRS

STD STANDARD

STL JST STEEL JOIST

STL RF DK STEEL ROOF DECK

STOR STORAGE

STR STRINGERS

STRB/HRN STROBE/HORN

SUB FL SUBFLOOR

SV SHEET VINYL

SW SIDEWALK

T --------------------

T TREAD

T/S TUB/SHOWER

TC TERRA COTTA

TD TRENCH DRAIN

TEL TELEPHONE

TEMP TEMPORARY

TER TERRAZZO

TFF TOP OF FINISH FLOOR

THK THICKNESS

TK BD TACKBOARD

TMPD GL TEMPERED GLASS

TN TRUE NORTH

TOC TOP OF CONCRETE

TOF TOP OF FOOTING

TOM TOP OF MASONRY

TOP TOP OF PARAPET

TOPO TOPOGRAPHY

TOS TOP OF SLAB

TOW TOP OF WALL

TRANS TRANSPARENT FINISH

TRTD TREATED

TV TELEVISION

TYP TYPICAL

U -------------------

UNF/UNFIN UNFINISHED

UON UNLESS OTHERWISE NOTED

UTL UTILITY

V -------------------

VB VAPOR BARRIER

VCT VINYL COMPOSITION TILE

VERT VERTICAL

VEST VESTIBULE

VIF VERIFY IN FIELD

VOL VOLUME

VT VINYL TILE

VTR VENT THRU ROOF

W -------------------

W/ WITH

WC WATER COOLER

WD WOOD

WP WATERPROOF

WT WEIGHT

Y -------------------

YD YARD

EXTERIOR ELEVATION &

SECTION MARK

DETAIL MARK

INTERIOR WINDOW TAG

(IN FLOOR PLANS)

NEW WORK NOTE

SECTION NUMBER

SHEET NUMBER

DETAIL NUMBER

SHEET NUMBER

NORTH ARROW

DEMOLITION NOTE

COLUMN GRID AND

MARK

ROOM NAME,

NUMBER & AREA

REVISION MARK

ELEVATION MARK

INTERIOR

ELEVATION MARK

ELEVATION

NUMBER(S)

SHEET NUMBER

Name

Elevation

8'4' 16'0

SCALE: 1/8"=1'-0"

GRAPHIC SCALE

FOCUS AREA

N

Room

Rm_Occupancy

150 SF

A-101

X

X

DRAWING SYMBOLS

1A-101

A-101

FIRE EXTINGUISHERFEC

PROJECT NORTH

TRUE NORTH

DRAWING /DETAIL LOCATION DESIGNATION

DRAWING/DETAIL TITLE

DRAWING SCALE

DRAWING DESIGNATIONA1

PARTITION TAG

0E

EXTERIOR WINDOW TAG

(IN BUILDING ELEVATIONS)

W10

ACCESSIBLE WATER

CLOSET FRONT

ELEVATION

STANDARD WATER

CLOSET FRONT

ELEVATION

ACCESSIBLE

WALL MOUNTED

SOAP

DISPENSER

ACCESSIBLE WATER CLOSET

SIDE ELEVATION

ACCESSIBLE

LAVATORY

FRONT

ELEVATION

C E

N T

E R

L

IN

E O

F C

O N

T R

O L S

TYPICAL FIXTURE AND ACCESSORY MOUNTING HEIGHT LEGEND

TOILET SEAT COVER

DISPENSER

B O

T T

O M

O F

R E

F L E

C T

IV

E

S U

R F

A C

E

MIRROR

1' - 6"

F A

C E

O F

W A

L L

M A

X

IM

U M

F A

C E

O F

W A

L L

F A

C E

O F

W A

L L

3' - 0" 6"

1' - 5"

1' - 0" 3' - 6"

9" MAXIMUM

7" MINIMUM

3' - 3"

M

IN

IM

U

M

F A

C E

O F

W A

L L

F A

C E

O F

W A

L L

EQ EQ

M A

X

IM

U M

M A

X

IM

U M

GRAB

BAR

GRAB

BAR

TOILET TISSUE

DISPENSOR

ACCESSIBLE

URINAL SIDE

ELEVATION

STANDARD

URINAL SIDE

ELEVATION

ACCESSIBLE WALL

MOUNTED PAPER TOWEL

DISPENSER/ WASTE

RECEPTACLE COMBO

ACCESSIBLE WALL

MOUNTED AUTOMATIC

TOUCHLESS TOWEL

DISPENSER

C E

N T

E R

L

IN

E O

F C

O N

T R

O L S

C E

N T

E R

L

IN

E O

F D

IS

P

E N

S E

R

T O

P O

F R

E C

E P

T A

C L E

ACCESSIBLE WALL

MOUNTED WASTE

RECEPTACLE

ACCESSIBLE

SANITARY

NAPKIN/TAMPON

VENDOR

M A

X

IM

U M

M A

X

IM

U M

M A

X

IM

U M

C O

IN

S

L O

T S

F A

C E

O F

W A

L L

F A

C E

O F

W A

L L

FIRE EXTINGUISHER

CABINET AND/OR

BRACKET

ACCESSIBLE/STANDARD

ELECTRIC WATER

COOLER (EWC) FRONT

ELEVATION

T O

P O

F S

P O

U T

O U

T L E

T

FULL HEIGHT

MIRROR

ACCESSIBLE

SHELF

(WOMEN'S TOILET

ROOM ONLY)

M A

X

IM

U M

M

IN

IM

U

M

M

IN

IM

U

M

M

A X

IM

U

M

M A

X

IM

U M

A

D A

SHOWER CURTAIN

ROD

F A

C E

O F

W A

L L

SOAP DISH

S H

O W

E R

H E

A D

UTILITY SHELF WITH

MOP/BROOM

HOLDER

T O

P O

F

A C

C E

S S

O R

Y

ACCESSIBLE

SANITARY

NAPKIN

DISPOSAL

T O

P

C E

S S

O R

Y

STANDARD

HAT/COAT/ROBE

HOOK

T O

P

C E

S S

O R

Y

STANDARD

WATER CLOSET

SIDE ELEVATION

F A

C E

O F

W A

L L

9" MAXIMUM

7" MINIMUM

M A

X

IM

U M

TOILET TISSUE

DISPENSOR

NOTE:

INSULATE ALL EXPOSED PIPES UNDER LAVATORIES IN

ACCORDANCE WITH ANSI, ADA, AND ABA STANDARDS.

BABY

CHANGING

STATION

NUMBERING SYSTEM

A - 2 01

DISCIPLINE:

C - CIVIL

L - LANDSCAPE

A - ARCHITECTURE

M - MECHANICAL

E - ELECTRICAL

P - PLUMBING

S - STRUCTURAL

K - FOOD SERVICE

SERIES NUMBER

SHEET NUMBER WITHIN

SERIES

ARCHITECTURAL LEGEND

EARTH

CONCRETE

RIGID INSULATION

PORCELAIN TILE -

AS INDICATED

METAL

GYPSUM WALL BOARD

WOOD (FINISH)

WOOD (ROUGH)

BLANKET/BATT INSULATION

GLASS

ACOUSTICAL CEILING TILE

SPRAY FOAM INSULATION-

AS INDICATED

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

A-001

A B

B R

E V

IA

T

IO

N

S

M O

U N

T

IN

G H

E

IG

H T

S

A N

D S

Y M

B O

L S

B U

IL

D

IN

G

S

/6

R

E N

O V

A T

IO

N

L

IN

C O

L N

H A

L L

L

IN

C O

L N

H A

L L

W E

S T

P O

IN

T

N

E W

Y O

R K

D S

T E

L T

Z E

R

J O

W E

N S

D M

A N

T Y

M

A R

C H

W D

S -1

-R

-0

W D

S -1

-C

-0 -L

REVISED RTA SUBMISSION 03/01/2023

1 1/2" = 1'-0"

TITLE

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

IS

S U

E D

B Y

A M

E N

D M

E N

T

/1

/2

/4

5' - 0" 3' - 11 1/2" +/-

A

F

B

B

C

F

D ED

E

MEN'S

RESTROOM

B212

WOMEN'S

RESTROOM

B211

0J

0J

0F 0F

0L

A-401B4

B1

B2

B3 A-401 A2

A1

A3

A4

0K

0K 0K

0B

0B

5' - 0"3' - 9" +/-

C

/4

1' - 7 1/2"

A

3'-7" CLEAR

MIN TO FACE

OF FINISH

9 1/2"

CL

7"9" 3 3/4"6 1/2 "

5 3/4"

/4

EXCLUDING

TILE FINISH

FROM FACE

OF WALL

TILE FINISH

E X

C L U

D

IN

G

T

IL

E F

IN

IS

H

FROM FACE

OF WALL

TILE FINISH

11 3/4"

M

IN

IM

IZ

E

0G

F

4' - 5 3/4"

3' - 0 3/4"

CLEAR TO FACE

OF TILE FINISH

3 1/4"

0E

A-606

A5

0K PARTITION GWB CONTINUOUS AT

CHASE PARTITION

6' - 8 1/4"

A

B

B

G

G

D

D

C

F

E

6' - 3"

/4

/4

A-401 D2

D1

D4

D3

MEN'S

RESTROOM

0F

0F

0D

0A

0J

0J

/2

A-401

C3

C1

C2C4

0L

3' - 8 1/2"

0F

0B

/2

0A

3' - 8 1/2" 6' - 0"

/4

5' - 0" 3' - 0" 3' - 0"

5' - 0" 3' - 0" 3' - 0"

CLEAR

TO

FACE

OF

WALL

FINISH

WOMEN'S

RESTROOM

1' - 3 1/2"

0B

/2

R O

U G

H O

P E

N

IN

G

/2

/4

CL

CL

/2

/2

C L

E A

R

T

O F

A C

E

L L

F

IN

IS

H

C L

E A

R

T

O F

A C

E

L L

F

IN

IS

H

TO FACE OF CMU

0R

0E

0R

T O

F A

E

R

A M

E T

O F

A

E

R A

M E

0K

0L

0K

0K

0F

0D

A-606

B5

H

H

3' - 6" 6"

3' - 6" 6"

KEYNOTES

1. HPDE FLOOR MOUNTED, FLOOR SUPPORTED TOILET

PARTITIONS, TP-1

2. 54" HIGH MIRROR FULL LENGTH OF COUNTER

3. GYPSUM WALL BOARD AND METAL STUD FURRED

PARTITION

4. NOT USED

5. PORCELAIN BULLNOSE TILE, PBN-1

6. MOSAIC WALL TILE (COINS), MWT-2

7. PORCELAIN WALL TILE, PWT-1

8. PORCELAIN TILE BASE, PTB-1

9. PORCELAIN TILE BASE (PBT-1) AND PORCELAIN WALL

TILE (PWT-1) TO BE CENTERED ON PILASTER AS

GRAPHICALLY SHOWN AT THIS LOCATION

10. QUARTZ COUNTERTOP AND APRON, QZ-1

11. PLASTIC LAMINATE MILLWORK, PL-1

12. NOT USED

13. 36" HIGH MIRROR TO EXTEND FULL WIDTH OF THE

COUNTERTOP. VERIFY WIDTH IN FIELD PRIOR TO

ORDERING.

14. METAL EDGE STRIP, MES-1

15. PROVIDE 1'-4" FROM FACE OF WALL TILE FINISH AT

WALL TO CENTERLINE OF THE LAVATORY AT COUNTER

(TYPICAL AT ALL LAVATORIES)

16. PROVIDE LAYER OF 5/8" GWB OVER 7/8" HAT CHANNEL

AT THE MASONRY OPENING AND TIE INTO THE SAME

CONSTRUCTION AT THE FACE OF THE CORRIDOR CMU

WALL.

17. PAINT, PT-15.

18. MITER EDGES OF TILE AROUND ACCESSORY

19. RAIN LEADER

LEGEND

EXISTING CONSTRUCTION

NEW CONSTRUCTION

EQ EQ

NOTE: ALIGN

WALL TILE

GROUT JOINTS

W/ FLOOR TILE

GROUT JOINTS,

U.N.O

GH

B

E

NOTE: ALIGN

WALL TILE

GROUT JOINTS

W/ FLOOR TILE

GROUT JOINTS,

U.N.O

5 17

NOTE: ALIGN

WALL TILE

GROUT JOINTS

W/ FLOOR TILE

GROUT JOINTS,

U.N.O

E

E

EQ. EQ.

G B

NOTE: ALIGN

WALL TILE

GROUT JOINTS

W/ FLOOR TILE

GROUT JOINTS,

U.N.O

H

NOTE: ALIGN

WALL TILE

GROUT JOINTS

W/ FLOOR TILE

GROUT JOINTS,

U.N.O

5 17

E

NOTE: ALIGN

WALL TILE

GROUT JOINTS

W/ FLOOR TILE

GROUT JOINTS,

U.N.O

14 1

B

NOTE: ALIGN

WALL TILE

GROUT JOINTS

W/ FLOOR TILE

GROUT JOINTS,

U.N.O

E 3

B

11 8

NOTE: ALIGN

WALL TILE

GROUT JOINTS

W/ FLOOR TILE

GROUT JOINTS,

U.N.O

N

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

A-401

E N

L A

R G

E D

R E

S T

R O

O M

F L

O O

R P

L A

N S

B U

IL

D

IN

G

S

/6

R

E N

O V

A T

IO

N

L

IN

C O

L N

H A

L L

L

IN

C O

L N

H A

L L

W E

S T

P O

IN

T

N

E W

Y O

R K

A F

L O

R A

J O

W E

N S

D M

A N

T Y

M

A R

C H

W D

S -1

-R

-0

W D

S -1

-C

-0 -L

REVISED RTA SUBMISSION 03/01/2023

1/4" = 1'-0" B5

LEVEL B2 - ENLARGED RESTROOM FLOOR PLAN

1/4" = 1'-0" C5

LEVEL 1 -4 - ENLARGED RESTROOM FLOOR PLAN

TOILET ACCESSORY SCHEDULE

MARK DESCRIPTION

A 18" VERTICAL GRAB BAR + 36" GRAB BAR + 42" GRAB BAR

B SURFACE MOUNTED TOILET SEAT COVER DISPENSER

C SURFACE MOUNTED SANITARY NAPKIN DISPOSAL

D VANITY MOUNTED SOAP DISPENSER

E SEMI-RECESSED MOUNTED PAPER TOWEL DISPENSER AND

WASTE RECEPTACLE

F SURFACE MOUNTED TOILET TISSUE DISPENSER

G 36" HAT & COAT RACK W/ 4 HOOKS

H BABY CHANGING STATION - ROOMS 183 AND 184 ONLY

0 2' 4' 8'

SCALE: 1/4" = 1'-0"

1/4" = 1'-0" D1

MEN'S - NORTH - WEST ELEVATION

1/4" = 1'-0"

D2

MEN'S - NORTH - NORTH ELEVATION

1/4" = 1'-0" D3

MEN'S - NORTH - EAST ELEVATION

1/4" = 1'-0"

D4

MEN'S - NORTH - SOUTH ELEV. A

1/4" = 1'-0" C1

WOMEN'S - NORTH - WEST ELEVATION

1/4" = 1'-0"

C2

WOMEN'S - NORTH -

NORTH ELEVATION

1/4" = 1'-0" C3

WOMEN'S - NORTH - EAST ELEVATION

1/4" = 1'-0"

C4

WOMEN'S - NORTH -

SOUTH ELEVATION

1/4" = 1'-0" B1

MEN'S - SOUTH - WEST ELEVATION

1/4" = 1'-0"

B2

MEN'S - SOUTH - NORTH ELEVATION

1/4" = 1'-0" B3

MEN'S - SOUTH - EAST ELEVATION

1/4" = 1'-0"

B4

MEN'S - SOUTH - SOUTH ELEVATION

1/4" = 1'-0" A1

WOMEN'S - SOUTH -

WEST ELEVATION

1/4" = 1'-0" A2

WOMEN'S - SOUTH - NORTH ELEVATION

1/4" = 1'-0"

A3

WOMEN'S - SOUTH -

EAST ELEVATION

1/4" = 1'-0" A4

WOMEN'S - SOUTH - SOUTH ELEVATION

REFER TO ENLARGED PLAN C5 ON SHEET A-401 FOR NOTES ON CLEAR

DIMENSIONS TO FINISHES AT TOILET PARTITIONS/URINALS AND FOR THE

LAVATORY DISTANCE FROM WALL FINISH. THEY APPLY TO THIS FLOOR PLAN.

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

IS

S U

E D

B Y

A M

E N

D M

E N

T

/1

/2

1 1

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

AG202

S

IG

N A

G E

IN

T E

R

IO

R S

IG

N

E L E

V A

T

IO

N S

B U

IL

D

IN

G

S

/6

R

E N

O V

A T

IO

N

L

IN

C O

L N

H A

L L

L

IN

C O

L N

H A

L L

W E

S T

P O

IN

T

N

E W

Y O

R K

S P

O O

N

M P

E R

E Z

D M

A N

T Y

M

A R

C H

W D

S -1

-R

-0

W D

S -1

-C

-0 -L

REVISED RTA SUBMISSION 03/01/2023

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

IS

S U

E D

B Y

A M

E N

D M

E N

T

/1

/2

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

AG203

S

IG

N A

G E

IN

T E

R

IO

R S

IG

N

E L E

V A

T

IO

N S

B U

IL

D

IN

G

S

/6

R

E N

O V

A T

IO

N

L

IN

C O

L N

H A

L L

L

IN

C O

L N

H A

L L

W E

S T

P O

IN

T

N

E W

Y O

R K

A F

L O

R A

A F

L O

R A

D M

A N

T Y

M

A R

C H

W D

S -1

-R

-0

W D

S -1

-C

-0 -L

REVISED RTA SUBMISSION 03/01/2023

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

IS

S U

E D

B Y

A M

E N

D M

E N

T

/1

/2

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

AG501

S

IG

N A

G E

L A

Y O

U T

S

B U

IL

D

IN

G

S

/6

R

E N

O V

A T

IO

N

L

IN

C O

L N

H A

L L

L

IN

C O

L N

H A

L L

W E

S T

P O

IN

T

N

E W

Y O

R K

A F

L O

R A

A F

L O

R A

D M

A N

T Y

M

A R

C H

W D

S -1

-R

-0

W D

S -1

-C

-0 -L

REVISED RTA SUBMISSION 03/01/2023

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

IS

S U

E D

B Y

A M

E N

D M

E N

T

/1

/2

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

AG502

S

IG

N A

G E

L A

Y O

U T

S

B U

IL

D

IN

G

S

/6

R

E N

O V

A T

IO

N

L

IN

C O

L N

H A

L L

L

IN

C O

L N

H A

L L

W E

S T

P O

IN

T

N

E W

Y O

R K

A F

L O

R A

A F

L O

R A

D M

A N

T Y

M

A R

C H

W D

S -1

-R

-0

W D

S -1

-C

-0 -L

REVISED RTA SUBMISSION 03/01/2023

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

IS

S U

E D

B Y

A M

E N

D M

E N

T

/1

/2

PUMP

ROOM

B302

MECHANICAL

ROOM

B300

MECHANICAL

ROOM

B301

MECHANICAL

ROOM

B301A

MECHANICAL

ROOM

B305

CL S

CL N

MECHANICAL

XB301

UTILITY TUNNEL

XB300

STAIR B

XB3-102

DEMOLITION KEYNOTES

1. REMOVE GWB AND METAL STUD PARTITION AND HOLLOW

METAL DOORS AND DOOR FRAMES WITHIN THE

PARTITION.

2. REFER TO STRUCTURAL FOR REMOVAL OF SLAB ON

GRADE AT SALLY PORT.

3. REMOVE WOOD DOOR AND DOOR FRAME AND

ASSOCIATED DOOR HARDWARE. SALVAGE WOOD DOOR

AND RETAIN FOR OWNER.

4. REMOVE LOUVERS AND EMBRASURE WINDOWS IN THE

EXTERIOR WALL. REFER TO THE EXTERIOR ELEVATIONS

FOR LOCATION.

5. REFER TO STRUCTURAL FOR REMOVAL OF SALLY PORT

BRICK ARCH ABOVE.

6. REMOVE FLOOR SLAB IN LOCATION OF ELEVATOR -

REFER TO STRUCTURAL FOR MORE INFORMATION

7. REMOVE FURRED PARTITION AROUND EXISTING STEEL

COLUMN TO REMAIN.

X

8. CUT AND REMOVE EXISTING MASONRY STAIR WALL TO

CREATE NEW OPENING FROM FLOOR TO STRUCTURE

ABOVE. COORDINATE SUPPORT FOR STRUCTURAL SLAB

ABOVE WITH STRUCTURAL DRAWINGS.

9. COORDINATE STAIR REMOVAL WITH NEW STAIR. SEE

C2/A-406 FOR NEW STAIR PLACEMENT.

10. EXISTING WOOD DOOR TO REMAIN.

11. FOR SLAB REMOVAL FOR BELOW GRADE PIPING, REFER

TO STRUCTURAL

LEGEND

EXISTING CONSTRUCTION

DEMOLITION

GENERAL NOTES

1. THE DEMOLITION AND ALTERATION NOTES ARE NOT

ALL INCLUSIVE. PRIOR TO DEMOLITION INSPECT AND

ASSESS EACH AREA AND FULFILL THE INTENT OF THE

DEMOLITION WORK INDICATED BY THE CONTRACT

DOCUMENTS. VERIFY ALL CONDITIONS AND

DIMENSIONS WITHIN THE CONTRACT LIMITS.

DEVIATIONS FROM THE CONTRACT DOCUMENTS

NECESSITATED BY FIELD CONDITIONS SHALL BE

BROUGHT TO THE ATTENTION OF THE COR PRIOR TO

PROCEEDING WITH THE WORK.

2. CONTRACTOR MUST CONSULT WITH THE OWNER

REPRESENTATIVE (COR) IN ADVANCE OF DOING WORK

TO DETERMINE DISPOSITION OF ALL FIXTURES,

CABINETS, SERVICES, EQUIPMENT AND ITEMS TO BE

REMOVED DURING THE DEMOLITION. CONTRACTOR TO

REMOVE AND PROPERLY DISPOSE OF ALL EXISTING

FURNITURE AND EQUIPMENT, LOOSE ITEMS AND

DEBRIS ETC. LEFT BEHIND BY OWNER.

3. PROVIDE TEMPORARY BARRIERS, BARRICADES,

LIGHTING, FIRE PROTECTION, ETC. TO PROTECT

PERSONNEL AND ADJACENT SPACES PER THE

REQUIREMENTS OF DIVISION 01 SECTION “TEMPORARY

FACILITIES AND CONTROLS.”

4. PROVIDE TEMPORARY SAFEGUARDS AS REQUIRED TO

PROTECT EXISTING FINISHES AND EQUIPMENT TO

REMAIN DURING DEMOLITION AND CONSTRUCTION.

5. WHERE EXISTING CONSTRUCTION, INCLUDING BUT NOT

LIMITED TO, PARTITIONS, FLOORS AND BASES, DOOR

AND WINDOW FRAMES, CEILINGS, CASEWORK,

EQUIPMENT, ELECTRICAL AND MECHANICAL DEVICES,

FIXTURES AND EQUIPMENT ARE REMOVED OR

ALTERED, REPAIR ADJACENT SURFACES DISTURBED

BY DEMOLITION OR ALTERATION WORK AND PREPARE

THESE SURFACES TO RECEIVE NEW SCHEDULED

FINISHES. REPAIRS TO SURFACES DEEMED BY THE

ARCHITECT AND OWNER (COR) TO BE

UNSATISFACTORY FOR THE PURPOSE MUST BE

REMOVED AND REPLACED IN KIND.

6. HOLES IN UL RATED FLOORS AND WALLS RESULTING

FROM DEMOLITION OR REMOVALS MUST BE REPAIRED

IN A MANNER CONSISTENT WITH THE ADJACENT UL

RATED CONSTRUCTION AND BE ACCEPTABLE TO THE

AUTHORITY HAVING JURISDICTION.

7. REPAIRS TO FIRE, SMOKE OR ACOUSTICALLY RATED

WALLS, FLOORS OR CEILINGS SHALL BE MADE WITH

MATERIALS APPROPRIATE TO ACHIEVE THE SAME

RATING AS THE EXISTING.

8. MECHANICAL AND ELECTRICAL DEMOLITION IN

FINISHED SPACES MUST BE REMOVED SUCH THAT

EXISTING TERMINATIONS WILL BE CONCEALED BEHIND

THE NEW CONSTRUCTION.

9. FOR EXTERIOR DEMOLITION THAT INCLUDES, RAILINGS,

STAIRS, SEE EXTERIOR ENVELOPE SHEETS.

10. AT BOTH SIDES OF THE STRUCTURAL CMU CORRIDOR

WALLS AND THE EGRESS STAIR WALLS FACING

OCCUPIED SPACE IN THE RENOVATION AREA THE

PLASTER FINISH IS TO BE REMOVED AND ABATED (PER

HAZARDOUS MATERIAL REQUIREMENTS) BACK TO THE

FACE OF CMU. THE PLASTER FINISH WITHIN EGRESS

STAIRS ARE TO REMAIN AND NOT BE ABATED. CENTRAL

STAIR PLASTER FINISHES ARE TO REMAIN.

11. REFER TO THE HAZMAT FLOOR`` PLANS FOR MORE

INFORMATION ON REMOVAL OF EXISTING PLASTER.

N

8'4' 16'0

SCALE: 1/8"=1'-0"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

AD101

L E

V E

L B

D

E M

O L

IT

IO

N P

L A

N

B U

IL

D

IN

G

S

/6

R

E N

O V

A T

IO

N

L

IN

C O

L N

H A

L L

L

IN

C O

L N

H A

L L

W E

S T

P O

IN

T

N

E W

Y O

R K

A F

L O

R A

J O

W E

N S

D M

A N

T Y

M

A R

C H

W D

S -1

-R

-0

W D

S -1

-C

-0 -L

REVISED RTA SUBMISSION 03/01/2023

1/8" = 1'-0" C1

DEMOLITION PLAN - LEVEL B3

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

IS

S U

E D

B Y

A M

E N

D M

E N

T

/1

/2

DEPT.

STORAGE

B212

DEPT.

STORAGE

B213

MECHANICAL

ROOM

B218

DEPT.

STORAGE

B211

ELECTRICAL

ROOM

B210

WOMEN'S

TOILET

B204

CLASSROOM

B203

CLASSROOM

B202

CLASSROOM

B201

CLASSROOM

B200

MEN'S

TOILET

B205

JANITOR'S

CLOSET

B206CL S

CL N

CENTRAL STAIR

/ ENTRANCE

B201

CORRIDOR

B2100A

STAIR B

XB2-102

STAIR A

XB-201

UNEXCAVATED

1 2

11 11 11

TYP18

TYP19

12 12

5 5

SOCIAL

SCIENCE

SOCIAL

SCIENCE

ENGLISH

DEMOLITION KEYNOTES

1. REMOVE TWO HOUR RATED GWB AND METAL STUD

PARTITION AND WOOD DOORS/HOLLOW METAL DOOR

FRAMES WITHIN THE PARTITION.

2. REMOVE ONE HOUR RATED GWB AND METAL STUD

PARTITION AND WOOD DOORS/HOLLOW METAL DOOR

FRAME WITHIN THE PARTITION.

3. REMOVE HOLLOW METAL DOOR AND DOOR FRAME AND

ALL ASSOCIATED DOOR HARDWARE IN PARTITION TO

REMAIN.

4. REMOVE WOOD DOOR/HOLLOW METAL FRAME AND ALL

ASSOCIATED DOOR HARDWARE IN PARTITION TO REMAIN.

5. REMOVE LOUVERS AND EMBRASURE WINDOWS IN THE

EXTERIOR WALL. REFER TO THE EXTERIOR ELEVATIONS

FOR LOCATION.

6. REFER TO STRUCTURAL FOR REMOVAL OF FLOOR SLAB

OR SLAB AT RAMP. DARK GRAY SHADED AREA IN B211

AND B218 ARE THE BRICK ARCH AT SALLYPORT TO BE

REMOVED - REFER TO STRUCTURAL.

7. REMOVE MASONRY WALL AND WOOD DOOR/DOOR

FRAME TO THE STRUCTURE ABOVE

8. REMOVE SHAFT WALL PARTITION.

9. REMOVE WOOD DOOR AND HOLLOW METAL FRAME IN

EXISTING OPENING TO REMAIN AND PREP FOR NEW

DOOR AND FRAME.

10. REMOVE MASONRY WALL AREA FOR NEW DOOR

OPENING. COORDINATE SIZE OF OPENING WITH NEW

WORK.

11. REMOVE FULL HEIGHT GWB AND METAL STUD PARTITION

OR PLUMBING CHASE PARTITIONS.

12. REMOVE SUSPENDED ACOUSTICAL CEILING TILES,

GRIDS, AND HANGERS.

13. REMOVE ALL PLUMBING WATER CLOSETS, SINKS, SINK

COUNTERS, MOP SINKS. REFER TO PLUMBING FOR MORE

INFORMATION.

14. REMOVE TOILET STALL PARTITIONS

15. REMOVE RESILIENT FLOOR FINISH AND IMMEDIATE

SUBSTRATE AND WALL BASE IN ROOMS AND CORRIDOR.

16. REMOVE CERAMIC TILE FLOOR FINISH AND WALL BASE.

17. REMOVE WALL MOUNTED COAT HOOKS AND ASSOCIATED

TRIM.

18. REMOVE GWB FURRED PARTITIONS BACK TO MASONRY

EXTERIOR WALL CONSTRUCTION FROM FLOOR TO THE

STRUCTURAL SLAB ABOVE. AT WINDOWS REMOVE

INTERIOR WOOD TRIM AT SILL, HEAD, AND JAMS.

19. REMOVE WOOD TRIM AT WINDOWS BACK TO WINDOW

JAMB AND REMOVE WINDOW IN ENTIRETY.

20. REMOVE ELEVATOR DOOR AND DOOR JAMB AND ALL

ASSOCIATED SILL AND JAMB ELEMENTS. REMOVE STEP

AT THE BASE OF THE ELEVATOR OPENING DOWN TO THE

MAIN B3 FLOOR LEVEL.

21. REMOVE EXTERIOR WOOD DOOR AND DOOR FRAME AND

ALL ASSOCIATED DOOR HARDWARE AND PREP FOR NEW

DOOR.

X

22. CUT WALL OPENING TO ACCOMMODATE NEW

MECHANICAL LOUVER.

LEGEND

EXISTING CONSTRUCTION

DEMOLITION

GENERAL NOTES

1. THE DEMOLITION AND ALTERATION NOTES ARE NOT

ALL INCLUSIVE. PRIOR TO DEMOLITION INSPECT AND

ASSESS EACH AREA AND FULFILL THE INTENT OF THE

DEMOLITION WORK INDICATED BY THE CONTRACT

DOCUMENTS. VERIFY ALL CONDITIONS AND

DIMENSIONS WITHIN THE CONTRACT LIMITS.

DEVIATIONS FROM THE CONTRACT DOCUMENTS

NECESSITATED BY FIELD CONDITIONS SHALL BE

BROUGHT TO THE ATTENTION OF THE COR PRIOR TO

PROCEEDING WITH THE WORK.

2. CONTRACTOR MUST CONSULT WITH THE OWNER

REPRESENTATIVE (COR) IN ADVANCE OF DOING WORK

TO DETERMINE DISPOSITION OF ALL FIXTURES,

CABINETS, SERVICES, EQUIPMENT AND ITEMS TO BE

REMOVED DURING THE DEMOLITION. CONTRACTOR TO

REMOVE AND PROPERLY DISPOSE OF ALL EXISTING

FURNITURE AND EQUIPMENT, LOOSE ITEMS AND

DEBRIS ETC. LEFT BEHIND BY OWNER.

3. PROVIDE TEMPORARY BARRIERS, BARRICADES,

LIGHTING, FIRE PROTECTION, ETC. TO PROTECT

PERSONNEL AND ADJACENT SPACES PER THE

REQUIREMENTS OF DIVISION 01 SECTION “TEMPORARY

FACILITIES AND CONTROLS.”

4. PROVIDE TEMPORARY SAFEGUARDS AS REQUIRED TO

PROTECT EXISTING FINISHES AND EQUIPMENT TO

REMAIN DURING DEMOLITION AND CONSTRUCTION.

5. WHERE EXISTING CONSTRUCTION, INCLUDING BUT NOT

LIMITED TO, PARTITIONS, FLOORS AND BASES, DOOR

AND WINDOW FRAMES, CEILINGS, CASEWORK,

EQUIPMENT, ELECTRICAL AND MECHANICAL DEVICES,

FIXTURES AND EQUIPMENT ARE REMOVED OR

ALTERED, REPAIR ADJACENT SURFACES DISTURBED

BY DEMOLITION OR ALTERATION WORK AND PREPARE

THESE SURFACES TO RECEIVE NEW SCHEDULED

FINISHES. REPAIRS TO SURFACES DEEMED BY THE

ARCHITECT AND OWNER (COR) TO BE

UNSATISFACTORY FOR THE PURPOSE MUST BE

REMOVED AND REPLACED IN KIND.

6. HOLES IN UL RATED FLOORS AND WALLS RESULTING

FROM DEMOLITION OR REMOVALS MUST BE REPAIRED

IN A MANNER CONSISTENT WITH THE ADJACENT UL

RATED CONSTRUCTION AND BE ACCEPTABLE TO THE

AUTHORITY HAVING JURISDICTION.

7. REPAIRS TO FIRE, SMOKE OR ACOUSTICALLY RATED

WALLS, FLOORS OR CEILINGS SHALL BE MADE WITH

MATERIALS APPROPRIATE TO ACHIEVE THE SAME

RATING AS THE EXISTING.

8. MECHANICAL AND ELECTRICAL DEMOLITION IN

FINISHED SPACES MUST BE REMOVED SUCH THAT

EXISTING TERMINATIONS WILL BE CONCEALED BEHIND

THE NEW CONSTRUCTION.

9. FOR EXTERIOR DEMOLITION THAT INCLUDES, RAILINGS,

STAIRS, SEE EXTERIOR ENVELOPE SHEETS.

10. AT BOTH SIDES OF THE STRUCTURAL CMU CORRIDOR

WALLS AND THE EGRESS STAIR WALLS FACING

OCCUPIED SPACE IN THE RENOVATION AREA THE

PLASTER FINISH IS TO BE REMOVED AND ABATED (PER

HAZARDOUS MATERIAL REQUIREMENTS) BACK TO THE

FACE OF CMU. THE PLASTER FINISH WITHIN EGRESS

STAIRS ARE TO REMAIN AND NOT BE ABATED. CENTRAL

STAIR PLASTER FINISHES ARE TO REMAIN.

11. REFER TO THE HAZMAT FLOOR`` PLANS FOR MORE

INFORMATION ON REMOVAL OF EXISTING PLASTER.

N

8'4' 16'0

SCALE: 1/8"=1'-0"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

AD102

L E

V E

L B

D

E M

O L

IT

IO

N P

L A

N

B U

IL

D

IN

G

S

/6

R

E N

O V

A T

IO

N

L

IN

C O

L N

H A

L L

L

IN

C O

L N

H A

L L

W E

S T

P O

IN

T

N

E W

Y O

R K

A F

L O

R A

J O

W E

N S

D M

A N

T Y

M

A R

C H

W D

S -1

-R

-0

W D

S -1

-C

-0 -L

REVISED RTA SUBMISSION 03/01/2023

1/8" = 1'-0" C1

DEMOLITION PLAN - LEVEL B2

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

IS

S U

E D

B Y

A M

E N

D M

E N

T

/1

/2

DN

OFFICE

B119

INSTRUCTOR

OFFICE

B118

OFFICE

B120

OFFICE

B117

STORAGE

CLOSET

B116

OFFICE

B115

MEN'S

TOILET

B114

JANITOR'S

CLOSET

B113

WOMEN'S

TOILET

B112

OFFICE

B121

OFFICE

B122

OFFICE

B123

OFFICE

B124

OFFICE

B125

OFFICE

B111

LECTURE

HALL

B101

LECTURE

HALL

B102FACULTY

LOUNGE

B100

OFFICE

B106

OFFICE

B107

OFFICE

B108

OFFICE

B109

OFFICE

B109A

OFFICE

B110

OFFICE

B111A

OFFICE

SUITE

B103

OFFICE

B104

CL S

CL N

STAIR B

XB1-102

CENTRAL STAIR

B101

STAIR A

XB1-101

CORRIDOR

B100B

CORRIDOR

B1100A

TYP1

TYP1

TYP1

TYP2

12 13

TYP7

TYP15

TYP15

3 3

TYP2

TYP2

TYP2

AT ENTIRE EXTERIOR WALL

AT ENTIRE EXTERIOR WALL

13 811

6 33

TYP1

13 8

TYP2 AT

ENTIRE

EXTERIOR

WALL

TYP2

AT

ENTIRE

EXTERIOR

WALL

20 21

STORAGE

DEMOLITION KEYNOTES

1. REMOVE FULL HEIGHT GWB AND METAL STUD PARTITION

AND WOOD DOOR/HOLLOW METAL FRAME IF IN

PARTITION.

2. REMOVE GWB FURRED PARTITIONS BACK TO MASONRY

EXTERIOR WALL CONSTRUCTION FROM FLOOR TO THE

STRUCTURAL SLAB ABOVE.

3. REMOVE WOOD DOOR/HOLLOW METAL FRAME AND ALL

ASSOCIATED DOOR HARDWARE IN PARTITION TO REMAIN.

4. REMOVE SLAB AT ELEVATOR OR MECHANICAL SHAFT -

REFER TO STRUCTURAL FOR MORE INFORMATION.

5. REMOVE SHAFT WALL OR PLUMBING CHASE PARTITION.

6. REMOVE MASONRY WALL AREA FOR NEW DOOR

OPENING. COORDINATE SIZE OF OPENING WITH NEW

WORK.

7. REMOVE WOOD TRIM AT WINDOWS AT HEAD, SILL AND

JAMBS.

16. REMOVE WOOD DOOR, DOOR FRAME AND SIDELITES

AND ADJACENT PARTITION.

17. REMOVE ELEVATOR DOOR AND DOOR JAMB AND THE

ASSOCIATED SILL AND JAMB ELEMENTS.

18.. REMOVE WOOD DOOR AND DOOR FRAME AND ADJACENT

PARTITION WITHIN THE ARCHED OPENING. REMOVE

ASSOCIATED DOOR HARDWARE.

19. REMOVE RAMP HANDRAIL- BOTH SIDES OF RAMP

20. REMOVE GWB CEILING SYSTEM IN THE CENTRAL STAIR.

REFER TO GENERAL NOTE 12.

21. REMOVE RESILIENT FLOORING, FLOOR FINISH

SUBSTRATE, WALL BASE, AND ADHESIVE. CLEAN AND

REPAIR SUBSTRATE FOR NEW FLOORING AND BASE AS

SCHEDULED.

8. REMOVE SUSPENDED ACOUSTICAL CEILING TILES,

GRIDS, AND HANGERS. REFER TO ELECTRICAL FOR

DEMOLITION OF CEILING MOUNTED ITEMS.

9. REMOVE PLUMBING WATER CLOSETS, SINKS, SINK

COUNTERS, MOP SINKS. REFER TO PLUMBING DRAWINGS

FOR MORE INFORMATION.

10. REMOVE TOILET STALL PARTITIONS.

11. REMOVE RESILIENT FLOOR FINISH AND IMMEDIATE

SUBSTRATE AND WALL BASE IN ROOMS AND CORRIDOR.

12. REMOVE CERAMIC TILE FLOOR FINISH AND WALL BASE.

13. REMOVE CARPET FLOOR FINISH AND WALL BASE

14. REMOVE FOLDING PANEL PARTITION AND THE

ASSOCIATED FIXED PARTITION AND STRUCTURAL

SUPPORTS.

15. REMOVE EXTERIOR WINDOW IN ITS ENTIRETY.

X

LEGEND

EXISTING CONSTRUCTION

DEMOLITION

GENERAL NOTES

1. THE DEMOLITION AND ALTERATION NOTES ARE NOT

ALL INCLUSIVE. PRIOR TO DEMOLITION INSPECT AND

ASSESS EACH AREA AND FULFILL THE INTENT OF THE

DEMOLITION WORK INDICATED BY THE CONTRACT

DOCUMENTS. VERIFY ALL CONDITIONS AND

DIMENSIONS WITHIN THE CONTRACT LIMITS.

DEVIATIONS FROM THE CONTRACT DOCUMENTS

NECESSITATED BY FIELD CONDITIONS SHALL BE

BROUGHT TO THE ATTENTION OF THE COR PRIOR TO

PROCEEDING WITH THE WORK.

2. CONTRACTOR MUST CONSULT WITH THE OWNER

REPRESENTATIVE (COR) IN ADVANCE OF DOING WORK

TO DETERMINE DISPOSITION OF ALL FIXTURES,

CABINETS, SERVICES, EQUIPMENT AND ITEMS TO BE

REMOVED DURING THE DEMOLITION. CONTRACTOR TO

REMOVE AND PROPERLY DISPOSE OF ALL EXISTING

FURNITURE AND EQUIPMENT, LOOSE ITEMS AND

DEBRIS ETC. LEFT BEHIND BY OWNER.

3. PROVIDE TEMPORARY BARRIERS, BARRICADES,

LIGHTING, FIRE PROTECTION, ETC. TO PROTECT

PERSONNEL AND ADJACENT SPACES PER THE

REQUIREMENTS OF DIVISION 01 SECTION “TEMPORARY

FACILITIES AND CONTROLS.”

4. PROVIDE TEMPORARY SAFEGUARDS AS REQUIRED TO

PROTECT EXISTING FINISHES AND EQUIPMENT TO

REMAIN DURING DEMOLITION AND CONSTRUCTION.

5. WHERE EXISTING CONSTRUCTION, INCLUDING BUT NOT

LIMITED TO, PARTITIONS, FLOORS AND BASES, DOOR

AND WINDOW FRAMES, CEILINGS, CASEWORK,

EQUIPMENT, ELECTRICAL AND MECHANICAL DEVICES,

FIXTURES AND EQUIPMENT ARE REMOVED OR

ALTERED, REPAIR ADJACENT SURFACES DISTURBED

BY DEMOLITION OR ALTERATION WORK AND PREPARE

THESE SURFACES TO RECEIVE NEW SCHEDULED

FINISHES. REPAIRS TO SURFACES DEEMED BY THE

ARCHITECT AND OWNER (COR) TO BE

UNSATISFACTORY FOR THE PURPOSE MUST BE

REMOVED AND REPLACED IN KIND.

6. HOLES IN UL RATED FLOORS AND WALLS RESULTING

FROM DEMOLITION OR REMOVALS MUST BE REPAIRED

IN A MANNER CONSISTENT WITH THE ADJACENT UL

RATED CONSTRUCTION AND BE ACCEPTABLE TO THE

AUTHORITY HAVING JURISDICTION.

7. REPAIRS TO FIRE, SMOKE OR ACOUSTICALLY RATED

WALLS, FLOORS OR CEILINGS SHALL BE MADE WITH

MATERIALS APPROPRIATE TO ACHIEVE THE SAME

RATING AS THE EXISTING.

8. MECHANICAL AND ELECTRICAL DEMOLITION IN

FINISHED SPACES MUST BE REMOVED SUCH THAT

EXISTING TERMINATIONS WILL BE CONCEALED BEHIND

THE NEW CONSTRUCTION.

9. FOR EXTERIOR DEMOLITION THAT INCLUDES, RAILINGS,

STAIRS, SEE EXTERIOR ENVELOPE SHEETS.

10. AT BOTH SIDES OF THE STRUCTURAL CMU CORRIDOR

WALLS AND THE EGRESS STAIR WALLS FACING

OCCUPIED SPACE IN THE RENOVATION AREA THE

PLASTER FINISH IS TO BE REMOVED AND ABATED (PER

HAZARDOUS MATERIAL REQUIREMENTS) BACK TO THE

FACE OF CMU. THE PLASTER FINISH WITHIN EGRESS

STAIRS ARE TO REMAIN AND NOT BE ABATED. CENTRAL

STAIR PLASTER FINISHES ARE TO REMAIN.

11. REFER TO THE HAZMAT FLOOR PLANS FOR MORE

INFORMATION ON REMOVAL OF EXISTING PLASTER.

12. CENTRAL STAIR CEILING AREAS ONLY - WHERE A

KEYNOTE INDICATES TO REMOVE THE GWB CEILING

AREA. IT IS ASSUMED YET NOT VERIFIED THAT THE

ORIGINAL CEILING MATERIALS AND ASSOCIATED

DECORATIVE TRIM HAVE BEEN REMOVED IN THE

PREVIOUS PROJECT. TO ENSURE THAT THE ORIIGINAL

MATERIALS ARE NOT DAMAGED IF THEY DO REMAIN, THE

CONTRACTOR IS TO CAREFULLY REMOVE THE GWB

CEILING STARTING IN THE CENTER OF CEILING BETWEEN

COLUMNS AND CONFIRM THE EXISTING CONDITIONS AND

WHETHER ORIGINAL CEILING MATERIALS AND MOLDINGS

REMAIN ABOVE THE CEILING AND INFORM THE

CONTRACTING OFFICER ACCORDINGLY.

N

8'4' 16'0

SCALE: 1/8"=1'-0"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

AD103

L E

V E

L B

D

E M

O L

IT

IO

N P

L A

N

B U

IL

D

IN

G

S

/6

R

E N

O V

A T

IO

N

L

IN

C O

L N

H A

L L

L

IN

C O

L N

H A

L L

W E

S T

P O

IN

T

N

E W

Y O

R K

A F

L O

R A

J O

W E

N S

D M

A N

T Y

M

A R

C H

W D

S -1

-R

-0

W D

S -1

-C

-0 -L

REVISED RTA SUBMISSION 03/01/2023

1/8" = 1'-0" C1

DEMOLITION PLAN - LEVEL B1

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

IS

S U

E D

B Y

A M

E N

D M

E N

T

/1

/2

CONFERENCE

ROOM

DEBATE

ROOM

OFFICE

OFFICE

OFFICE

RECEPTION

OFFICE

SECRETARIES

OFFICE

OFFICE

BREAK

ROOM

COPY

ROOM

107A

OFFICE

CONFERENCE

ROOM

OFFICE

OFFICE

OFFICE

OFFICE

122A

OFFICE

OFFICE

STORAGE

CLOSET

OFFICE

MEN'S

TOILET

JANITOR'S

CLOSET

WOMEN'S

TOILET

CL S

CL N

CENTRAL

STAIR/ENTRY

STAIR A

X1-101

STAIR B

X1-102

CORRIDOR

100A

CORRIDOR

100B

CORRIDOR

100C

13 8

TYP1

TYP2

TYP7TYP15

TYP15

TYP2

AT ENTIRE EXTERIOR WALL

AT ENTIRE EXTERIOR WALL

TYP1

TYP1

TYP1

TYP2 AT ENTIRE

EXTERIOR

WALL

TYP2 AT ENTIRE

EXTERIOR

WALL

11 13

DEMOLITION KEYNOTES

1. REMOVE FULL HEIGHT GWB AND METAL STUD PARTITION

AND WOOD DOOR/HOLLOW METAL FRAME IF IN

PARTITION.

2. REMOVE GWB FURRED PARTITIONS BACK TO MASONRY

EXTERIOR WALL CONSTRUCTION FROM FLOOR TO THE

STRUCTURAL SLAB ABOVE.

3. REMOVE WOOD DOOR/HOLLOW METAL FRAME AND ALL

ASSOCIATED DOOR HARDWARE IN PARTITION TO REMAIN.

4. REMOVE SLAB AT ELEVATOR, MECHANICAL SHAFT, OR

LEVEL 1 SOUTH WING ENTRANCE - REFER TO

STRUCTURAL FOR MORE INFORMATION.

5. REMOVE SHAFT WALL OR PLUMBING CHASE PARTITION.

6. REMOVE MASONRY WALL AREA FOR NEW DOOR OR

WINDOW OPENING. COORDINATE SIZE OF OPENING WITH

NEW WORK.

7. REMOVE WOOD TRIM AT WINDOWS AT SILL, HEAD AND

JAMBS.

16. REMOVE EXTERIOR WOOD DOOR, DOOR FRAME AND ALL

ASSOCIATED DOOR HARDWARE. SALVAGE WOOD DOOR

FOR GOVERNMENT, AND COORDINATE STORAGE WITH

COR. REMOVE SLAB AREA NEAR DOOR HINGES TO

ACCOMMODATE FUTURE DOOR FLOOR MOUNTED

CLOSER.

17. REMOVE ELEVATOR DOOR AND DOOR JAMB AND ALL

ASSOCIATED SILL AND JAMB ELEMENTS.

18. REMOVE WOOD DOOR AND DOOR FRAME AND ADJACENT

PARTITION WITHIN THE ARCHED OPENING. REMOVE

ASSOCIATED DOOR HARDWARE.SALVAGE DOOR, FRAME

AND SIDE LITES FOR GOVERNMENT. COORDINATE

STORAGE WITH THE COR.

19. REMOVE COUNTERTOP, BASE AND WALL CABINETS, AND

SINK IN BREAK ROOM.

20. REMOVE COUNTER AND WITH STORAGE CABINET BELOW.

21. REMOVE WALL CABINETS.

22. REMOVE BASE CABINETS WITH MAIL SLOT CABINET

ABOVE.

8. REMOVE SUSPENDED ACOUSTICAL CEILING TILES,

GRIDS, AND HANGERS. REFER TO ELECTRICAL FOR

DEMOLITION OF CEILING MOUNTED ITEMS.

9. REMOVE PLUMBING WATER CLOSETS, SINKS, SINK

COUNTERS, MOP SINKS. REFER TO PLUMBING DRAWINGS

FOR MORE INFORMATION.

10. REMOVE TOILET STALL PARTITIONS.

11. REMOVE RESILIENT FLOOR FINISH AND IMMEDIATE

SUBSTRATE AND WALL BASE IN ROOMS AND CORRIDOR.

12. REMOVE CERAMIC TILE FLOOR FINISH AND WALL BASE.

13. REMOVE CARPET FLOOR FINISH AND WALL BASE

14. REMOVE FOLDING PANEL PARTITION AND THE

ASSOCIATED FIXED PARTITION AND STRUCTURAL

SUPPORTS.

15. REMOVE EXTERIOR WINDOW IN ITS ENTIRETY.

X

23. REMOVE GWB CEILING SYSTEM BETWEEN THE WOOD

BEAMS.

24. REMOVE THE GWB CEILING SYSTEM.

25. WOOD BEAMS OR PLASTER ARCH ARE RETAINED,

PROTECT FROM DAMAGE.

26. FLOOR FINISH IN ALL AREAS OF THE CENTRAL STAIR IS TO

BE RETAINED, PROTECT FROM DAMAGE.

27. REMOVE VERTICAL WOOD ELEMENT THAT IS SEPARATE

FROM THE EXISTING WOOD PANELING TO REMAIN. TAKE

CARE TO PROTECT WALL MOUNTED WOOD PANELING

WHEN REMOVING.

23. REMOVE GWB CEILING SYSTEM BETWEEN THE WOOD

BEAMS IN CENTRAL STAIR.

LEGEND

EXISTING CONSTRUCTION

DEMOLITION

GENERAL NOTES

1. THE DEMOLITION AND ALTERATION NOTES ARE NOT

ALL INCLUSIVE. PRIOR TO DEMOLITION INSPECT AND

ASSESS EACH AREA AND FULFILL THE INTENT OF THE

DEMOLITION WORK INDICATED BY THE CONTRACT

DOCUMENTS. VERIFY ALL CONDITIONS AND

DIMENSIONS WITHIN THE CONTRACT LIMITS.

DEVIATIONS FROM THE CONTRACT DOCUMENTS

NECESSITATED BY FIELD CONDITIONS SHALL BE

BROUGHT TO THE ATTENTION OF THE COR PRIOR TO

PROCEEDING WITH THE WORK.

2. CONTRACTOR MUST CONSULT WITH THE OWNER

REPRESENTATIVE (COR) IN ADVANCE OF DOING WORK

TO DETERMINE DISPOSITION OF ALL FIXTURES,

CABINETS, SERVICES, EQUIPMENT AND ITEMS TO BE

REMOVED DURING THE DEMOLITION. CONTRACTOR TO

REMOVE AND PROPERLY DISPOSE OF ALL EXISTING

FURNITURE AND EQUIPMENT, LOOSE ITEMS AND

DEBRIS ETC. LEFT BEHIND BY OWNER.

3. PROVIDE TEMPORARY BARRIERS, BARRICADES,

LIGHTING, FIRE PROTECTION, ETC. TO PROTECT

PERSONNEL AND ADJACENT SPACES PER THE

REQUIREMENTS OF DIVISION 01 SECTION “TEMPORARY

FACILITIES AND CONTROLS.”

4. PROVIDE TEMPORARY SAFEGUARDS AS REQUIRED TO

PROTECT EXISTING FINISHES AND EQUIPMENT TO

REMAIN DURING DEMOLITION AND CONSTRUCTION.

5. WHERE EXISTING CONSTRUCTION, INCLUDING BUT NOT

LIMITED TO, PARTITIONS, FLOORS AND BASES, DOOR

AND WINDOW FRAMES, CEILINGS, CASEWORK,

EQUIPMENT, ELECTRICAL AND MECHANICAL DEVICES,

FIXTURES AND EQUIPMENT ARE REMOVED OR

ALTERED, REPAIR ADJACENT SURFACES DISTURBED

BY DEMOLITION OR ALTERATION WORK AND PREPARE

THESE SURFACES TO RECEIVE NEW SCHEDULED

FINISHES. REPAIRS TO SURFACES DEEMED BY THE

ARCHITECT AND OWNER (COR) TO BE

UNSATISFACTORY FOR THE PURPOSE MUST BE

REMOVED AND REPLACED IN KIND.

6. HOLES IN UL RATED FLOORS AND WALLS RESULTING

FROM DEMOLITION OR REMOVALS MUST BE REPAIRED

IN A MANNER CONSISTENT WITH THE ADJACENT UL

RATED CONSTRUCTION AND BE ACCEPTABLE TO THE

AUTHORITY HAVING JURISDICTION.

7. REPAIRS TO FIRE, SMOKE OR ACOUSTICALLY RATED

WALLS, FLOORS OR CEILINGS SHALL BE MADE WITH

MATERIALS APPROPRIATE TO ACHIEVE THE SAME

RATING AS THE EXISTING.

8. MECHANICAL AND ELECTRICAL DEMOLITION IN

FINISHED SPACES MUST BE REMOVED SUCH THAT

EXISTING TERMINATIONS WILL BE CONCEALED BEHIND

THE NEW CONSTRUCTION.

9. FOR EXTERIOR DEMOLITION THAT INCLUDES, RAILINGS,

STAIRS, SEE EXTERIOR ENVELOPE SHEETS.

10. AT BOTH SIDES OF THE STRUCTURAL CMU CORRIDOR

WALLS AND THE EGRESS STAIR WALLS FACING

OCCUPIED SPACE IN THE RENOVATION AREA THE

PLASTER FINISH IS TO BE REMOVED AND ABATED (PER

HAZARDOUS MATERIAL REQUIREMENTS) BACK TO THE

FACE OF CMU. THE PLASTER FINISH WITHIN EGRESS

STAIRS ARE TO REMAIN AND NOT BE ABATED. CENTRAL

STAIR PLASTER FINISHES ARE TO REMAIN.

11. REFER TO THE HAZMAT FLOOR`` PLANS FOR MORE

INFORMATION ON REMOVAL OF EXISTING PLASTER.

WAITING AREA

CENTRAL

STAIR/ENTRY

23 25

TYP.25

TYP.

TYP.

D1

A-405

N

8'4' 16'0

SCALE: 1/8"=1'-0"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

AD104

L E

V E

L

D E

M O

L

IT

IO

N

P L A

N

B U

IL

D

IN

G

S

/6

R

E N

O V

A T

IO

N

L

IN

C O

L N

H A

L L

L

IN

C O

L N

H A

L L

W E

S T

P O

IN

T

N

E W

Y O

R K

A F

L O

R A

J O

W E

N S

D M

A N

T Y

M

A R

C H

W D

S -1

-R

-0

W D

S -1

-C

-0 -L

REVISED RTA SUBMISSION 03/01/2023

1/8" = 1'-0" C1

DEMOLITION PLAN - LEVEL 1

1/8" = 1'-0" A3

REFLECTED CEILING PLAN - FOR CENTRAL STAIR DEMO

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

IS

S U

E D

B Y

A M

E N

D M

E N

T

/1

/2

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

COPY

ROOM

204A

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CONFERENCE

ROOM

MEN'S

TOILET

JANITOR'S

CLOSET

WOMEN'S

TOILET

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CL S

CL N

STAIR B

X2-102

STAIR A

X2-101

CORRIDOR

200A

CENTRAL STAIR

CORRIDOR

200B

TYP7TYP15

TYP2 AT ENTIRE EXTERIOR WALL

1 TYP1

13 8

TYP1

TYP2 AT ENTIRE

EXTERIOR

WALL

TYP2

AT ENTIRE

EXTERIOR

WALL

TYP2 AT ENTIRE EXTERIOR WALL

TYP15

TYP7

8 13

AT ENTIRE

EXTERIOR

WALL

DEMOLITION KEYNOTES

1. REMOVE FULL HEIGHT GWB AND METAL STUD PARTITION

AND WOOD DOOR/HOLLOW METAL FRAME IF IN

PARTITION.

2. REMOVE GWB FURRED PARTITIONS BACK TO MASONRY

EXTERIOR WALL CONSTRUCTION FROM FLOOR TO THE

STRUCTURAL SLAB ABOVE.

3. REMOVE WOOD DOOR/HOLLOW METAL FRAME AND ALL

ASSOCIATED DOOR HARDWARE IN PARTITION TO REMAIN.

4. REMOVE SLAB AT ELEVATOR OR MECHANICAL SHAFT OR

NEW STAIR - REFER TO STRUCTURAL FOR MORE

INFORMATION.

5. REMOVE SHAFT WALL OR PLUMBING CHASE PARTITION.

6. REMOVE MASONRY WALL AREA FOR NEW DOOR OR

CASED OPENING. COORDINATE SIZE OF OPENING WITH

NEW WORK.

7. REMOVE WOOD TRIM AT WINDOWS BACK TO WINDOW

JAMB.

16. REMOVE ELEVATOR DOOR AND DOOR JAMB AND

ASSOCIATED SILL AND JAMB ELEMENTS.

17. REMOVE WOOD DOOR AND DOOR FRAME AND

ADJACENT PARTITION WITHIN THE ARCHED OPENING.

REMOVE ASSOCIATED DOOR HARDWARE.

18. REMOVE RESILIENT FLOORING, FLOOR FINISH

SUBSTRATE, WALL BASE, AND ADHESIVE. CLEAN AND

REPAIR SUBSTRATE FOR NEW FLOORING AND BASE AS

SCHEDULED.

19. REMOVE PARTITION AND DOOR/HOLLOW METAL

FRAME AND ASSOCIATED ELEMENTS.

8. REMOVE SUSPENDED ACOUSTICAL CEILING TILES,

GRIDS, AND HANGERS. REFER TO ELECTRICAL FOR

DEMOLITION OF CEILING MOUNTED ITEMS.

9. REMOVE PLUMBING WATER CLOSETS, SINKS, SINK

COUNTERS, MOP SINKS. REFER TO PLUMBING DRAWINGS

FOR MORE INFORMATION.

10. REMOVE TOILET STALL PARTITIONS.

11. REMOVE RESILIENT FLOOR FINISH AND IMMEDIATE

SUBSTRATE AND WALL BASE IN ROOMS AND CORRIDOR.

12. REMOVE CERAMIC TILE FLOOR FINISH AND WALL BASE.

13. REMOVE CARPET FLOOR FINISH AND WALL BASE

14. REMOVE THE GWB CEILING SYSTEM IN THE CENTRAL

STAIR. REFER TO GENERAL NOTE 12.

15. REMOVE EXTERIOR WINDOW IN ITS ENTIRETY.

X

LEGEND

EXISTING CONSTRUCTION

DEMOLITION

GENERAL NOTES

1. THE DEMOLITION AND ALTERATION NOTES ARE NOT

ALL INCLUSIVE. PRIOR TO DEMOLITION INSPECT AND

ASSESS EACH AREA AND FULFILL THE INTENT OF THE

DEMOLITION WORK INDICATED BY THE CONTRACT

DOCUMENTS. VERIFY ALL CONDITIONS AND

DIMENSIONS WITHIN THE CONTRACT LIMITS.

DEVIATIONS FROM THE CONTRACT DOCUMENTS

NECESSITATED BY FIELD CONDITIONS SHALL BE

BROUGHT TO THE ATTENTION OF THE COR PRIOR TO

PROCEEDING WITH THE WORK.

2. CONTRACTOR MUST CONSULT WITH THE OWNER

REPRESENTATIVE (COR) IN ADVANCE OF DOING WORK

TO DETERMINE DISPOSITION OF ALL FIXTURES,

CABINETS, SERVICES, EQUIPMENT AND ITEMS TO BE

REMOVED DURING THE DEMOLITION. CONTRACTOR TO

REMOVE AND PROPERLY DISPOSE OF ALL EXISTING

FURNITURE AND EQUIPMENT, LOOSE ITEMS AND

DEBRIS ETC. LEFT BEHIND BY OWNER.

3. PROVIDE TEMPORARY BARRIERS, BARRICADES,

LIGHTING, FIRE PROTECTION, ETC. TO PROTECT

PERSONNEL AND ADJACENT SPACES PER THE

REQUIREMENTS OF DIVISION 01 SECTION “TEMPORARY

FACILITIES AND CONTROLS.”

4. PROVIDE TEMPORARY SAFEGUARDS AS REQUIRED TO

PROTECT EXISTING FINISHES AND EQUIPMENT TO

REMAIN DURING DEMOLITION AND CONSTRUCTION.

5. WHERE EXISTING CONSTRUCTION, INCLUDING BUT NOT

LIMITED TO, PARTITIONS, FLOORS AND BASES, DOOR

AND WINDOW FRAMES, CEILINGS, CASEWORK,

EQUIPMENT, ELECTRICAL AND MECHANICAL DEVICES,

FIXTURES AND EQUIPMENT ARE REMOVED OR

ALTERED, REPAIR ADJACENT SURFACES DISTURBED

BY DEMOLITION OR ALTERATION WORK AND PREPARE

THESE SURFACES TO RECEIVE NEW SCHEDULED

FINISHES. REPAIRS TO SURFACES DEEMED BY THE

ARCHITECT AND OWNER (COR) TO BE

UNSATISFACTORY FOR THE PURPOSE MUST BE

REMOVED AND REPLACED IN KIND.

6. HOLES IN UL RATED FLOORS AND WALLS RESULTING

FROM DEMOLITION OR REMOVALS MUST BE REPAIRED

IN A MANNER CONSISTENT WITH THE ADJACENT UL

RATED CONSTRUCTION AND BE ACCEPTABLE TO THE

AUTHORITY HAVING JURISDICTION.

7. REPAIRS TO FIRE, SMOKE OR ACOUSTICALLY RATED

WALLS, FLOORS OR CEILINGS SHALL BE MADE WITH

MATERIALS APPROPRIATE TO ACHIEVE THE SAME

RATING AS THE EXISTING.

8. MECHANICAL AND ELECTRICAL DEMOLITION IN

FINISHED SPACES MUST BE REMOVED SUCH THAT

EXISTING TERMINATIONS WILL BE CONCEALED BEHIND

THE NEW CONSTRUCTION.

9. FOR EXTERIOR DEMOLITION THAT INCLUDES, RAILINGS,

STAIRS, SEE EXTERIOR ENVELOPE SHEETS.

10. AT BOTH SIDES OF THE STRUCTURAL CMU CORRIDOR

WALLS AND THE EGRESS STAIR WALLS FACING

OCCUPIED SPACE IN THE RENOVATION AREA THE

PLASTER FINISH IS TO BE REMOVED AND ABATED (PER

HAZARDOUS MATERIAL REQUIREMENTS) BACK TO THE

FACE OF CMU. THE PLASTER FINISH WITHIN EGRESS

STAIRS ARE TO REMAIN AND NOT BE ABATED. CENTRAL

STAIR PLASTER FINISHES ARE TO REMAIN.

11. REFER TO THE HAZMAT FLOOR PLANS FOR MORE

INFORMATION ON REMOVAL OF EXISTING PLASTER.

12. CENTRAL STAIR CEILING AREAS ONLY - WHERE A

KEYNOTE INDICATES TO REMOVE THE GWB CEILING

AREA. IT IS ASSUMED YET NOT VERIFIED THAT THE

ORIGINAL CEILING MATERIALS AND ASSOCIATED

DECORATIVE TRIM HAVE BEEN REMOVED IN THE

PREVIOUS PROJECT. TO ENSURE THAT THE ORIIGINAL

MATERIALS ARE NOT DAMAGED IF THEY DO REMAIN, THE

CONTRACTOR IS TO CAREFULLY REMOVE THE GWB

CEILING STARTING IN THE CENTER OF CEILING BETWEEN

COLUMNS AND CONFIRM THE EXISTING CONDITIONS AND

WHETHER ORIGINAL CEILING MATERIALS AND MOLDINGS

REMAIN ABOVE THE CEILING AND INFORM THE

CONTRACTING OFFICER ACCORDINGLY.

N

8'4' 16'0

SCALE: 1/8"=1'-0"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

AD105

L E

V E

L

D E

M O

L

IT

IO

N

P L A

N

B U

IL

D

IN

G

S

/6

R

E N

O V

A T

IO

N

L

IN

C O

L N

H A

L L

L

IN

C O

L N

H A

L L

W E

S T

P O

IN

T

N

E W

Y O

R K

A F

L O

R A

J O

W E

N S

D M

A N

T Y

M

A R

C H

W D

S -1

-R

-0

W D

S -1

-C

-0 -L

REVISED RTA SUBMISSION 03/01/2023

1/8" = 1'-0" C1

DEMOLITION PLAN - LEVEL 2

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

IS

S U

E D

B Y

A M

E N

D M

E N

T

/1

/2

MEN'S

TOILET

JANITOR'S

CLOSET

WOMEN'S

TOILET

OFFICE

COPY

ROOM

OFFICE

OFFICE

OFFICE

323A

OFFICE

CONFERENCE

ROOM

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

310A

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

BREAK

ROOM

OFFICE

OFFICE

CL S

CL N

TYP AT

ENTIRE

EXTERIOR

WALL

TYP7TYP15

TYP AT

ENTIRE

EXTERIOR

WALL

TYP1

TYP1

TYP AT

ENTIRE

EXTERIOR

WALL

TYP AT

ENTIRE

EXTERIOR

WALL

TYP15

TYP7

CENTRAL STAIR

18 18

TYP AT

ENTIRE

EXTERIOR

WALL

DEMOLITION KEYNOTES

1. REMOVE FULL HEIGHT GWB AND METAL STUD PARTITION

AND WOOD DOOR/HOLLOW METAL FRAME IF IN

PARTITION.

2. REMOVE GWB FURRED PARTITIONS BACK TO MASONRY

EXTERIOR WALL CONSTRUCTION FROM FLOOR TO THE

STRUCTURAL SLAB ABOVE.

3. REMOVE WOOD DOOR/HOLLOW METAL FRAME AND ALL

ASSOCIATED DOOR HARDWARE IN PARTITION TO REMAIN.

4. REMOVE SLAB AT ELEVATOR OR MECHANICAL SHAFT -

REFER TO STRUCTURAL FOR MORE INFORMATION.

5. REMOVE SHAFT WALL OR PLUMBING CHASE PARTITION.

6. REMOVE MASONRY WALL AREA FOR NEW DOOR

OPENING. COORDINATE SIZE OF OPENING WITH NEW

WORK.

7. REMOVE WOOD TRIM AT WINDOWS BACK TO WINDOW

JAMB.

16. REMOVE WOOD DOOR AND DOOR FRAME AND ADJACENT

PARTITION WITHIN THE ARCHED OPENING. REMOVE

ASSOCIATED DOOR HARDWARE.

17. REMOVE RESILIENT FLOORING, FLOOR FINISH

SUBSTRATE, WALL BASE, AND ADHESIVE. CLEAN AND

REPAIR SUBSTRATE FOR NEW FLOORING AND BASE AS

SCHEDULED.

18. REMOVE EXISTING GWB CEILING SYSTEM IN THE

CENTRAL STAIR. REFER TO GENERAL NOTE 12.

8. REMOVE SUSPENDED ACOUSTICAL CEILING TILES, GRIDS,

AND HANGERS. REFER TO ELECTRICAL FOR DEMOLITION

OF CEILING MOUNTED ITEMS.

9. REMOVE PLUMBING WATER CLOSETS, SINKS, SINK

COUNTERS, MOP SINKS. REFER TO PLUMBING DRAWINGS

FOR MORE INFORMATION.

10. REMOVE TOILET STALL PARTITIONS.

11. REMOVE RESILIENT FLOOR FINISH AND IMMEDIATE

SUBSTRATE AND WALL BASE IN ROOMS AND CORRIDOR.

12. REMOVE CERAMIC TILE FLOOR FINISH AND WALL BASE.

13. REMOVE CARPET FLOOR FINISH AND WALL BASE

14. REMOVE ELEVATOR DOOR AND DOOR JAMB AND THE

ASSOCIATED SILL AND JAMB ELEMENTS.

15. REMOVE EXTERIOR WINDOW IN ITS ENTIRETY.

X

LEGEND

EXISTING CONSTRUCTION

DEMOLITION

GENERAL NOTES

1. THE DEMOLITION AND ALTERATION NOTES ARE NOT

ALL INCLUSIVE. PRIOR TO DEMOLITION INSPECT AND

ASSESS EACH AREA AND FULFILL THE INTENT OF THE

DEMOLITION WORK INDICATED BY THE CONTRACT

DOCUMENTS. VERIFY ALL CONDITIONS AND

DIMENSIONS WITHIN THE CONTRACT LIMITS.

DEVIATIONS FROM THE CONTRACT DOCUMENTS

NECESSITATED BY FIELD CONDITIONS SHALL BE

BROUGHT TO THE ATTENTION OF THE COR PRIOR TO

PROCEEDING WITH THE WORK.

2. CONTRACTOR MUST CONSULT WITH THE OWNER

REPRESENTATIVE (COR) IN ADVANCE OF DOING WORK

TO DETERMINE DISPOSITION OF ALL FIXTURES,

CABINETS, SERVICES, EQUIPMENT AND ITEMS TO BE

REMOVED DURING THE DEMOLITION. CONTRACTOR TO

REMOVE AND PROPERLY DISPOSE OF ALL EXISTING

FURNITURE AND EQUIPMENT, LOOSE ITEMS AND

DEBRIS ETC. LEFT BEHIND BY OWNER.

3. PROVIDE TEMPORARY BARRIERS, BARRICADES,

LIGHTING, FIRE PROTECTION, ETC. TO PROTECT

PERSONNEL AND ADJACENT SPACES PER THE

REQUIREMENTS OF DIVISION 01 SECTION “TEMPORARY

FACILITIES AND CONTROLS.”

4. PROVIDE TEMPORARY SAFEGUARDS AS REQUIRED TO

PROTECT EXISTING…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .