L-502.pdf

PDF 188 KB Posted

Attached to
LINCOLN HALL RENOVATION, BLDG. 607 Federal contract opportunity
Solicitation number
W912DS23R0009
Issued by
Department of the Army Corps of Engineers Engineering District New York

About this file

This document package includes construction drawings and technical specifications for a federal construction contract opportunity. The U.S. Army Corps of Engineers, New York District is soliciting proposals for the renovation of Building 607, Lincoln Hall at West Point, New York. The drawings and specifications in the L-502 sheet provide requirements for landscape and erosion control elements of the project, including root barrier panels, native backfill materials, slope stabilization, and mulching. The solicitation number for the opportunity is W912DS23R0009, with proposals due on an unrestricted best value tradeoff basis. The scope of work encompasses renovations to Lincoln Hall and supporting facilities.

View the file

Other files for this federal contract opportunity

Other files attached to LINCOLN HALL RENOVATION, BLDG. 607, newest first.
File Type Posted
W912DS23R0009-0005.pdf PDF
A-429 - ENLARGED BRIEFING ROOM PLANS AND ELEVATIONS.pdf PDF
I-103 - LEVEL B1 FLOOR PLAN - FINISH.pdf PDF
I-602 - FINISH MATERIAL SCHEDULE.pdf PDF
Amendment 0004.pdf PDF
I-603 - FINISH MATERIAL SCHEDULE.pdf PDF
I-604 - FINISH MATERIAL SCHEDULE.pdf PDF
S-502.pdf PDF
A-202.pdf PDF
A-204.pdf PDF
A-401.pdf PDF
A-562 - MILLWORK DETAILS - BRIEFING ROOM.pdf PDF
Supplmental laydown area at Ordnance road.pptx PPTX presentation
Amendment 0003.pdf PDF
Amendment 0002.pdf PDF
21 30 00-001.2_R3 Fire Pump House Submittal (Cullum).pdf PDF
Lincoln Hall Drawing Changes 22 JUN 2023.pdf PDF
AS BUILT DRAWING 1A - Approximate Location of Knox BatteryAmend 1.pdf PDF
LH- H-101.pdf PDF
Lincoln Hall Specification Changes 22 JUN 2023.pdf PDF
C-001.pdf PDF
W912DS23R0009 0001.pdf PDF
CD101.pdf PDF
CS103.pdf PDF
2023.06.20 Lincoln Hall site walk through sign in sheet.pdf PDF
JA 009-23 Avaya Switch.pdf PDF
JA 011-23 Ventrol AHU.pdf PDF
JA 012-23 Identiv Card Access System.pdf PDF
JA 014-23 Shark Meter.pdf PDF
W912DS23R0009.pdf PDF
JA 006-23 Belden Brick.pdf PDF
JA 008-23-Ruabon Quarry Tile.pdf PDF
JA 010-23 Best Hardware Lock Cylinders and Cores.pdf PDF
Vol 1 WP Lincoln Hall Revised RTA Specifications 1 MAR 2023.pdf PDF
LH_VOLUME 03_Revised_RTA_2023-03-01.pdf PDF
Vol 2 WP Lincoln Hall Revised RTA Specifications 1 MAR 2023.pdf PDF
Vol 3 WP Lincoln Hall Revised RTA Specifications 1 MAR 2023.pdf PDF
LH_VOLUME 01_Revised_RTA_2023-03-01.pdf PDF
LH_VOLUME 04_Revised_RTA_2023-03-01.pdf PDF
JA 007-23 Distributed Antenna System.pdf PDF
JA 013-23 Monaco.pdf PDF
LH_VOLUME 02_Revised_RTA_2023-03-01.pdf PDF
Show all 42

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BARRIER PANEL

�24"

NEW OR EXISTING

TREE

CONCRETE CURB

18" ROOT BARRIER

NATIVE MATERIAL

BACKFILL

12" DEPTH ROOT CONTROL BARRIER WHEN TREE IS PLACED WITHIN 5 FEET OF SIDEWALK PAVING. 18" DEPTH WHEN TREE IS WITHIN 5 FEET OF ROADWAY CURB AND

GUTTER (ON ROADWAY SIDE ONLY). ROOT BARRIER PANELS ARE TO BE 20' IN LENGTH CENTERED ON TREE TRUNK, 10' FEET ON EACH SIDE OF THE TRUNK, RUNNING

PARALLEL TO PAVING AS SHOWN. IF DISTANCE FROM CENTER OF TREE IS LESS THAN 10' TO AN ADJACENT PAVED SURFACE, ALIGN BARRIER TO MATCH ADJACENT

PAVED SURFACE AND EXTEND REMAINING LENGTH OF PANEL ALONG PERIMETER OF TREE PLANTING/LANDSCAPE AREA.

LINEAR APPLICATION

NEW OR EXISTING TREE

CONCRETE SIDEWALK

12" ROOT BARRIER

BACKFILL- PREPARED

PLANTING SOIL

NATIVE MATERIAL

BACKFILL

GRADE

SECTION

GRADE

BACKFILL- PREPARED

PLANTING SOIL

5' OR LESS

5' OR LESS

SECTION

CONCRETE

SIDEWALK

CONCRETE

CURB/PAVED AREA

C

L

CENTER ROOT PANEL,

20' LENGTH ON TREE

TREE TRUNK

PLAN

LANDSCAPE

AREA

ROOT BARRIER PANEL, CENTERED

WITH 10' EACH SIDE OF TREE

EXTEND ROOT BARRIER PANEL ALONG ADJACENT

PAVEMENT FOR FULL LENGTH OF PANEL

1'0"1'0"

4"

TOP OF SLOPE

BOTTOM OF SLOPE

EARTH

CUT JUTE MATTING TO INSTALL

PLANT MATERIAL

INSTALL MULCH OVER JUTE

MATTING

EROSION CHECK SLOT (3"x3"), PLACE AT 50' INTERVALS ON

SLOPES, BACKFILL WITH SOIL

EROSION MATTING - JUTE

MATTING (BIO-DEGRADABLE

NETTING)

DOUBLE LAP ALL JOINTS,

STAPLES @ 9-12" ON HORZ.

LAPS 18" MAX. ON VERTICAL

LAPS

ANCHOR TRENCH

@ TOE

1. PREPARE SOIL BEFORE INSTALLING ROLLED EROSION CONTROL

PRODUCTS (RECPS), INCLUDING ANY NECESSARY APPLICATION OF LIME,

FERTILIZER, ETC.

2. BEGIN AT THE TOP OF THE SLOPE BY ANCHORING THE RECPS

3. ROLL THE RECPS DOWN OR HORIZONALLY ACROSS THE SLOPE

4. THE EDGED OF PARALLEL RECPS MUST BE STAPLED WITH OVERLAPP PER

THE MFG.

5. CUT JUTE MATTING TO ALLOW FOR INSTALLATION OF PLANT MATERIAL

6. COVER RECPS WITH MULCH PER SPECIFICATIONS OVER JUTE MATTING

R M

F

T S

T S

L A

N D

S C

A P

E

D

E T

A I L S

C I V

I L

L-502

D A

T E

M A

R K

D E

S C

R I P

T I O

N

D R

A W

N

B

Y

D E

S I G

N E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

C H

E C

K E

D

B

Y

I S

S U

E

D

A T

E

C O

N T

R A

C T

N

O

S O

L I C

I T

A T

I O

N

N

O

F I L

E

N

U M

B E

R

SHEET ID

F I L E

A M

E

U S

A

R M

Y

C

O R

P S

F

E

N G

I N

E E

R S

US Army Corps of Engineers

L I N

C O

H

L L

W E

T

P

I N

T

N

E W

Y

R

K

W D

S C

L

M

A R

C

A N

S I

D

W D

S R

B U

I L D

I N

G

R

E N

O V

A T

I O

N

L I N

C O

REVISED RTA SUBMISSION 3/1/2023

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

A1

ROOT BARRIER

NOT TO SCALE

D1

EROSION CONTROL BARRIER (ECB)

NOT TO SCALE

Sheets and Views
L-502
Sheet 1

File details come from the government source that posted it. Updated .