A-429 - ENLARGED BRIEFING ROOM PLANS AND ELEVATIONS.pdf
PDF 555 KB Posted
- Attached to
- LINCOLN HALL RENOVATION, BLDG. 607 Federal contract opportunity
- Solicitation number
- W912DS23R0009
About this file
This document package includes construction plans and specifications for the renovation of Building 607, Lincoln Hall at the United States Military Academy in West Point, New York. The project involves renovations to the briefing room including updated finishes, millwork, lighting, and acoustical treatments. The U.S. Army Corps of Engineers, New York District is soliciting proposals as an unrestricted Best Value Trade Off procurement through solicitation number W912DS23R0009 to award a firm-fixed price construction contract. The solicitation package includes drawings showing floor plans, elevations, and details of proposed renovations. Accompanying specifications include schedules for finishes, colors, and materials.
View the file
Other files for this federal contract opportunity
Show all 42
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
O O
7' - 10"
7' - 10" 7' - 10"
7' - 10"
A B
C D
A
A A
A
A
AB B
B
B B B
C
C
CD
D
D
D
C
A-551
B1
A B
CD
DC
1' - 2"
A-551
B2
A-551
B3
A-551
B4
C2 A-551
TYP
R E
M A
IN
T
Y P
E
X
IS
T T
O
1' - 2" REMAIN TYP.
EXIST. TO
8' - 8 1/2"3' - 1 3/4" 11' - 1"
9' - 5 1/4" 9' - 3"
ALIGN DOWNLIGHTS WITH DOWNLIGHTS
ON OPPOSITE SIDE OF ROOM
1' - 3"1' - 3" EQ EQ 1' - 3" 1' - 3"EQ EQ
ALIGN E
Q
E Q
/4
EQ 2' - 0" EQ
E Q
E Q
EQ 2' - 0" EQ
A-429
D3
A-429B3
A-429
C3
A-429 B4
0G
0G
0K
0K
0C
0E
0C
0C
0C
0C
0C
5' - 6"
/4
6' - 0" 12' - 10 1/2"
/4
0E
10 3/4"
0R 0R
5' - 9" RO
54' - 6" +/-
ENSURE CONTINUITY OF PARTITION TYPE 0C
AROUND RAIN LEADER AND SEAL GWB INTO FACE OF
EXTERIOR MASONRY WALL
PLACE ACOUSTICAL BATT INSULATION IN 0G PARTITION
FULL HEIGHT
0G
TERMINATE METAL STUD 1" OFF FACE OF MASONRY
AND FILL CAVITY WITH SPRAY FOAM
0C
6 3/4"
MINIMIZE FOOTPRINT
OF 0G PARTITION AROUND
THE RAIN LEADER
SPRAY FOAM (HATCHED AREA) - ENSURE CONTINUITY AT EXTERIOR WALL
6' - 3" RO
0R 0R
0E 0E0E
TO RO
1' - 0"
B
DOOR OPENING 110
ACROSS CORRIDOR TO
ALIGN WITH DOOR OPENING
150A
A
4 1/2" 4 1/2"
KEYNOTES #
1. AV2, MONITOR. REFER TO FURNITURE SHEETS. GFGI
2. ACOUSTICAL CEILING SYSTEM AS SCHEDULED
3. GWB SOFFIT - PAINTED AS SCHEDULED
4. WALL BASE AS SCHEDULED
5. MILLWORK - WOOD SPECIES: WHITE OAK. CUT: FLAT SAWN.
STAIN: PT-12, ALL EXPOSED EDGES TYPICAL
6. ARTWORK, OWNER FURNISHED OWNER INSTALLED
7. RECESSED FRAMELESS ACCESS PANEL. COORDINATE SIZE AND
LOCATION WITH FCU ACCESS REQUIREMENTS. PAINT TO MATCH
ADJACENT CEILING
(2) EQ. SPACES
4' - 0".
(3) EQ. SPACES - V.I.F.
7' - 7"
(4) EQ. SPACES - V.I.F.
6' - 0"
(3) EQ. SPACES - V.I.F.
7' - 7"
(2) EQ. SPACES
4' - 0". (2) EQ. SPACES3' - 0"(2) EQ. SPACES
EQ.EQ.EQEQ
B1
A-562
TYP
B2
A-562
TYP
B3
A-562
TYP
5 5
66 6 6
1 1
4 4
3 3
GENERAL NOTES
1. IN KEYNOTES, WORK IS CONSIDERED NEW UNLESS IT IS OTHERWISE NOTED
AS EXISTING.
2. REFER TO I-100 SERIES OF DRAWINGS FOR FINISH AND FURNITURE PLANS.
3. REFER TO I-400 SERIES OF DRAWINGS FOR ENLARGED FINISH FLOOR
PATTERN PLANS.
4. REFER TO I-600 SERIES OF DRAWINGS FOR COLOR MATERIAL LEGENDS AND
ROOM FINISH MATERIAL SCHEDULES.
5. ALL EXTERIOR WINDOWS TO RECEIVE WINDOW SHADE WT-1, UNLESS
NOTED OTHERWISE.
6. ALL WALLS TO BE PAINTED PT-1, UNLESS NOTED OTHERWISE.
7. CEILING COLORS SHALL APPLY TO CEILING SURFACES INCLUDING SOFFITS,
FURRED DOWN AREA, GRILLES, DIFFUSERS, REGISTERS, DUCTS, AND
ACCESS PANELS. CEILING COLOR SHALL ALSO APPLY TO JOIST, UNDERSIDE
OF ROOF DECK, CONDUIT, AND PIPING WHERE JOISTS AND DECK ARE
EXPOSED AND REQUIRED TO BE PAINTED.
8. REFER TO COMPREHENSIVE INTERIOR DESIGN (CID) BINDER FOR
FURNITURE, FIXTURES, AND EQUIPMENT SPECIFICATIONS.
9. ENLARGED OPEN OFFICE PLANS TO SHOW INTENT OF ACOUSTICAL WALL
PANELS ONLY
SD
GWB CEILING
RECESSED OR PENDANT CIRCULAR DOWNLIGHT
SMOKE DETECTOR (REFER TO FA DWGS)
EXIT SIGN LOCATION (REFER TO FA DWGS)
PENDANT MOUNTED UTILITY LIGHT FIXTURE
VENTILATION DIFFUSER - 2 x 2
CEILING MOUNTED FAN COIL UNIT
2' X 2' ACOUSTIC CEILING PANELS
PENDANT MOUNTED STRIP LIGHT FIXTURE
RECESSED LINEAR LIGHT FIXTURE (IN ACT)
SPRINKLER
DECORATIVE PENDANT LIGHT FIXTURE
REFLECTED CEILING PLAN LEGEND
TRACK LIGHT FIXTURE
RECESSED RECTANGULAR DOWNLIGHT
CIRCULAR PENDANT MOUNTED LIGHT FIXTURE
OPEN TO STRUCTURE (WITH EXPOSED
MECH DUCTWORK. REFER TO THE
FINISH MATERIAL SCHEDULE FOR
PAINTING REQUIREMENTS
LINEAR DIFFUSER
SUPPLY DIFFUSER - 2 x 2
EXHAUST / RETURN DIFFUSER - 2 x 2
2' X 4' ACOUSTIC CEILING PANEL
CLOUD WITH ALTERNATING GRID
SPECIALTY ACOUSTIC CEILING PANEL
CLOUD - IN CORRIDORS (CUSTOM SIZES)
CHILLED BEAM
N
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
A-429
E N
L A
R G
E D
B R
IE
F
IN
G
R O
O M
P L A
N S
A N
D E
L E
V A
T
IO
N S
B U
IL
D
IN
G
S
/6
R
E N
O V
A T
IO
N
L
IN
C O
L N
H A
L L
L
IN
C O
L N
H A
L L
W E
S T
P O
IN
T
N
E W
Y O
R K
A F
L O
R A
E N
O L A
N
D M
A N
T Y
M
A R
C H
W D
S -1
-R
-0
W D
S -1
-C
-0 -L
REVISED RTA SUBMISSION 03/01/2023
1/4" = 1'-0" C1
ENLARGED REFLECTED CEILING PLAN - BRIEFING ROOM
1/4" = 1'-0" B1
ENLARGED FLOOR PLAN - BRIEFING ROOM
1/4" = 1'-0" D3
BRIEFING ROOM - WEST ELEVATION
1/4" = 1'-0" B3
BRIEFING ROOM -
SOUTH ELEVATION
1/4" = 1'-0" B4
BRIEFING ROOM -
NORTH ELEVATION
1/4" = 1'-0" C3
BRIEFING ROOM - EAST ELEVATION
0 2' 4' 8'
SCALE: 1/4" = 1'-0"
M A
R K
D E
S C
R
IP
T I O
N D
A T
E
IS
S U
E D
V
IA
A M
E N
D M
E N
T /1
/2
| Sheets |
| A-429 - ENLARGED BRIEFING ROOM PLANS AND ELEVATIONS |
| A-562 - MILLWORK DETAILS - BRIEFING ROOM |
| I-103 - LEVEL B1 FLOOR PLAN - FINISH |
| I-602 - FINISH MATERIAL SCHEDULE |
| I-603 - FINISH MATERIAL SCHEDULE |
| I-604 - FINISH MATERIAL SCHEDULE |
File details come from the government source that posted it. Updated .