This document is an "Approval in Principle" review letter from the American Bureau of Shipping (ABS) regarding the cathodic protection plan for a federal contract opportunity. The review is limited to the structural attachment and alignment of steel support for anodes. The federal contract opportunity is for the procurement of three (3) welded steel barges to support the civil works maintenance and repair mission of the Detroit District of the U.S. Army Corps of Engineers. The barges have the following principal dimensions: Length Overall 150'-0", Beam (Overall) 38'-0", Depth (Molded at Centerline) 10'-4", and Depth (Molded at Side) 10'-0". The contractor will be required to fabricate and deliver the barges to the U.S. Army Engineer Detroit District in Sault Sainte Marie, MI and Duluth, MN. Liquidated damages, bid guarantee, payment, and performance bonding will be required. Requests for Information (RFIs) should be submitted no later than 21 June 2024 at 3:00 PM.
View the file
Other files for this federal contract opportunity
Show all 40
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ABS Global Engineering 275 Slater Street, Suite 1003 | Ottawa (ON), K1P 5H9 | Canada
Task – T2483255 Class No.: TBD Shipyard: TBD / Hull No.: TBD Flag: United States of America
Attention: Mr. Joshua Sebastian, The Shearer Group, Inc (442598)
The document shown in the attached list is reviewed in accordance with the applicable requirements of the following:
• ABS Rules for Building and Classing Steel Barges 2022
Please note our review is based on the following conditions:
1. At your request, we have carried out an “Approval in Principle” review of the documents in the attached list.
2. The primary objective of this review is to establish compliance in principle with the applicable ABS Rules, insofar as they relate to the details submitted.
3. Review is limited to structural attachment and alignment of steel support for anodes.
For any clarifications, contact Aldo Martino at (343) 633-1424 or amartino@eagle.org.
Very truly yours, Jihed Boulares Director, Engineering
Electronically Signed by: Aldo Martino
Electronically published by ABS Ottawa.
Reference T2483255, dated 19-DEC-2023.
mailto:amartino@eagle.org
ABS Global Engineering 275 Slater Street, Suite 1003 | Ottawa (ON), K1P 5H9 | Canada
Documents List
Drawing No. Rev. Title Status
888-B405-01 2 Cathodic Protection Plan Reviewed An Electronic copy of the document, appropriately stamped, is available in the ABS Client Portal.
Electronically published by ABS Ottawa.
Reference T2483255, dated 19-DEC-2023.