888-B405-02r1 Cathodic Protection Calculations (1).pdf

PDF 322 KB Posted

Attached to
CELRE Three Deck Barges Federal contract opportunity
Solicitation number
W912BU-24-B-0019
Issued by
Department of the Army Corps of Engineers Engineering District Philadeplhia

About this file

This document appears to be a set of cathodic protection calculations for a 150' x 38' x 10' deck barge. The calculations reference the ABS rules for cathodic protection of ships and assume a 5'6" draft. The wetted surface area is calculated to be 7,872.4 sq ft. Based on a current density of 2 mA/sq ft and a 5-year protective period, the calculations indicate that 30 anodes totaling 1,278 lbs are required, though 44 anodes totaling 1,936 lbs were actually installed. The document also includes dimensional details and surface area calculations for the barge.

The related federal contract opportunity is for the procurement of three 150' x 38' welded steel barges to support the civil works maintenance and repair mission of the Detroit District of the U.S. Army Corps of Engineers. The solicitation number is W912BU-24-B-0019, and the closing date for requests for information is June 21, 2024. This is an Invitation for Bid with liquidated damages and bonding requirements. The barges are to be delivered to the U.S. Army Engineer Detroit District in Sault Sainte Marie, MI and Duluth, MN.

View the file

Other files for this federal contract opportunity

Other files attached to CELRE Three Deck Barges, newest first.
File Type Posted
ABS Letter T2455022.pdf PDF
ABS Letter T2483253.pdf PDF
ABS Letter T2483246.pdf PDF
888-B415-01r2 Hatches and Manholes.pdf PDF
888-B301-02r3 Welding Schedule.pdf PDF
888-B215-01r4 General Arrangement.pdf PDF
888-B170-02r1 Dry Docking Calculations (1).pdf PDF
888-B105-01r3 Hull Lines and Offset-Manually.pdf PDF
ABS Letter T2455550.pdf PDF
ABS Letter T2483257.pdf PDF
ABS Letter T2455555.pdf PDF
ABS Letter T2481041.pdf PDF
888-B305-01r3 Deck and Bottom Plating.pdf PDF
888-B445-01r1 Lifesaving and Safety Plan.pdf PDF
888-B309-01r3 Transverse Structure.pdf PDF
888-B155-01r2 Intact Stability.pdf PDF
888-B115-01r1 Weight Estimate.pdf PDF
888-B311-01r3 Longitudinal Structure.pdf PDF
888-B427-01r2 Vertical Ladder Details.pdf PDF
888-B420-01r2 Deck Fitting Arrangement.pdf PDF
888-B335-01r3 Permanent Cargo Bin.pdf PDF
888-B160-01r1 Displacement and Deadweight Scales (PE).pdf PDF
888-B460-01r1 Hull Markings.pdf PDF
ABS Letter T2483249.pdf PDF
ABS Letter T2455523.pdf PDF
888-B410-02r2 Rub Rails and Fenders.pdf PDF
888-B170-01r1 Dry Docking Plan.pdf PDF
888-B335-02r3 Removable Cargo Bin.pdf PDF
888-B205-01r4 Outboard Profile.pdf PDF
888-B140-01r0 Load Line Calculation.pdf PDF
888-B405-01r2 Cathodic Protection.pdf PDF
W912BU-24-B-0019 0001.pdf PDF
ABS Letter T2483259.pdf PDF
ABS Letter T2483255.pdf PDF
888-B150-01r2 Damage Stability.pdf PDF
888-B301-01r3 Midship Section.pdf PDF
888-B125-01r1 Hydrostatic Calculations.pdf PDF
888-B307-01r3 Shell Plating.pdf PDF
888-B410-01r2 Tow Knees.pdf PDF
W912BU-24-B-0019.pdf PDF
Show all 40

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REV ZONE DRAWN CHKD

0 ‐ CTS JSS

1 ‐ WRH JSS

GENERAL NOTES

RESERVATIONS

NO.

SIZE REV

A 1

DATE: SCALE: SHEET 1 OF 4 NTS

APP'D BY: PROJECT NO. DWG. NO.

3383 888‐B405‐02

DATE: TSGI PROJ #:

Cathodic Protection Calculations2/2/2023 0430‐001

MARINE DESIGN CENTER

REFERENCES

THE SHEARER GROUP, INC.

3118 HARRISBURG BLVD, SUITE 100

HOUSTON, TX 77003

TEL: (281) 532‐2080 ~ FAX (281) 326‐1615

www.shearer‐group.com

CELRE DECK BARGES

DRAWN BY: CHECKED BY: 150'‐0" X 38'‐0" X 10'‐0"

CTS JSS

Cathodic Protection Plan 883‐B405‐01 1

DESCRIPTION DWG NO. REV.

1. ABS CATHODIC PROTECTION OF SHIPS, 2017 WAS USED AS BASIS FOR CALCULATIONS

2. CALCULATIONS ASSUME 5'‐6" DRAFT

REVISION HISTORY

DESCRIPTION DATE

1. INITIAL REVIEW 02FEB23

1. REVISED TITLE BLOCK 31MAY23

S e e A

B S O tt a w a L e tt e r R e f T D a te d

-O

C T -2 http://www.shearer‐group.com

PROJECT: 3383 Rev: 1 By: WRH

CALC: Date: 31MAY23 Checked: JSS

Anode Estimate

ABS method (see ref. 1)

Wtotal = Weight of anodes required for hull protection, (lbs)

Nreq'd = Number of anodes required

WInstalled = Actual weight of anodes installed, (lb)

NInstalled = Number of anodes installed

AW = Wetted surface area, (ft i = Current density, (A/ft ts = protective period, (yrs) fb = Utilization factor, (1 for constant use)

Qg = Electrochemical efficiency of anode, (A-h/lb)

Wanode = Weight of selected anode, (lb)

A W = 7872.4 i = 2 mA/ft (from Table 3, 8 kn operation)

= 0.002 A/ft ts = 5 years

= 43800 hours fb = 1 (for constant use)

Qg = 540 A-h/lb (for magnesium, from manuf)

Wanode = 44 lb (from manuf)

Wreq'd = 1278 lb WInstalled = 1936

Nreq'd = 30 NInstalled = 44

888‐B405‐02

Cathodic Protection Design Calculations ‐ Hull Anodes ft (via GHS)

௧௧ ൌ

ሺ ௪

ൈ ሻ ൈ ௦

S e e A

B S O tt a w a L e tt e r R e f T D a te d

-O

C T -2

Barge Dimensions

L (ft) W (ft) D (ft)

150 38 7

142892 992.3055556 Via GHS:

Bottom 733248 5092 SA w 7872.4 ft

Bow Rake 77976 541.5

Stern 38304 266

Total 1135312 in

= 7884.111 ft

0.645855941

78.33846154

888‐B405‐02

Cathodic Protection Design Calculations ‐ Surface Area Calculations

Wetted Surface Area (in

Sides (individual)

S e e A

B S O tt a w a L e tt e r R e f T D a te d

-O

C T -2

888‐B405‐02

Cathodic Protection Design Calculations ‐ Example Data

S e e A

B S O tt a w a L e tt e r R e f T D a te d

-O

C T -2