TE-11-6_FIRE ALARM ANNUAL INSP TESTING REPORT.pdf

PDF 300 KB Posted

Attached to
FACILITIES INVESTMENT SERVICES_REGION 6 FOR THE 63d READINESS DIVISION (RD) US ARMY RESERVES
Solicitation number
W9127S21Q0056
Issued by

View the file

Other files

File Type Posted
Region 6 Site Visit Minutes.pdf PDF
63d RD_REGION 6_FIS_PWS_Final Rev 2_20211031.pdf PDF
FIS_PWS_Section J_TE-09_Acronyms_and_ Definitions_20211028.pdf PDF
TE-10-4_GSA_FORM_55_07-2002.pdf PDF
Region6_FIS_PWS_Section J_TE-06_Quality Assurance Surveillance Plan_20211031.pdf PDF
TE-10-6_SPILL RESPONSE INCIDENT REPORT FORM.pdf PDF
TE-11-13_WET PIPE FIRE SPRINKLER SYSTEMS.pdf PDF
Region6_FIS_PWS_Section J_TE-01_Facilities Site Index and Maps_20211031.pdf PDF
DA_Fm5477_MAR2008.pdf PDF
FIS_PWS_Section J_TE-08_HVAC-Refrigeration Temp Standards_20211030.pdf PDF
TE-10-1_Certification of Work.pdf PDF
TE-11-2_DIESEL FIRE PUMP ASSEMBLIES.pdf PDF
TE-10-5_ENG_FORM_3394_2021Aug.pdf PDF
Region 6 Projnet Responses1.pdf PDF
FIS_PWS_Section J_TE-05_Deliverables_20211030.pdf PDF
TE-11-12_PORTABLE FIRE EXTINGUISHER ANNUAL INSPECTION.pdf PDF
TE-11-15_FIRE HYDRANT ANNUAL INSPECTION.pdf.pdf PDF
TE-11-4_ELECTRIC FIRE PUMP ASSEMBLIES.pdf PDF
TE-11-5_EMERGENCY LIGHT ANNUAL INSPECTION.pdf PDF
TE-10-2_Work Request Estimate and Completion Form.pdf PDF
TE-10-3_GSA_FORM_376_11-1967.pdf PDF
Contactor guidance doc_20210922 (002).pdf PDF
TE-11-11_NOTIFICATION AND INITIATING APPLIANCE SUPPLEMENT.pdf PDF
DA_Fm5479_MAR2008.pdf PDF
Region6_FIS_PWS_Section J_TE-03_Detailed Equipment Inventory_20211031.pdf PDF
TE-11-14_WATER STORAGE TANKS.pdf PDF
TE-11-8_KITCHEN HOOD SYSTEM ANNUAL INSPECTION.pdf PDF
Amendment_0002_21Q0056.pdf PDF
TE-11-10_MASS NOTIFICATION SYSTEM SUPP RECORD OF INSP AND TEST.pdf PDF
A.07.20_Site_Visit_Attendance_Sheet_21Q0056.pdf PDF
Region 6 Briefing Slides.pdf PDF
Region6_FIS_PWS_Section J_TE-04_Government Points of Contact_20211030.pdf PDF
TE-11-3_DRY PIPE FIRE SPRINKLER SYSTEMS.pdf PDF
FIS_PWS_Sect J_ATCH-05_ELINs_FIS_Region 6_20211031.xlsx XLSX spreadsheet
TE-11-9_MAIN DRAIN TEST.pdf PDF
Region6_FIS_PWS_Section J_TE-02_Summary Equipment Inventory_20211031.pdf PDF
FIS_PWS_Section J_TE-07_2018_GSA_PM Guide_FINAL.pdf PDF
FIS_PWS_Sect J_ATCH-05_ELINs_FIS-ENV_Region 6_20211031.xlsx XLSX spreadsheet
TE-11-1_DELUGE FIRE SPRINKLER SYSTEMS.pdf PDF
TE-11-7_FIRE DEPARTMENT CONNECTIONS.pdf PDF
W9127S21Q0056_AMENDMENT 0001_07-Oct-2021.pdf PDF
2018_GSA_PM_Guide_FINAL.pdf PDF
W9127S21Q0056_AMENDMENT 0001_20211007.pdf PDF
63d RD_REGION 6_FIS_PWS_Final REV 1_20210827.pdf PDF
W9127S21Q0056_R6 FIS Synopsis_Solicitation_20211006.pdf PDF
FIS_PWS_Sect J_ATCH-05_ELINs_FIS_Region 6_20210826.xlsx XLSX spreadsheet
TE-02_Region 6_Summary Equipment Inventory_26 August 2021.xlsx XLSX spreadsheet
63d RD DPW Operations Area Map FY20_20200909.pdf PDF
TE-03_Region 6_Detailed Equipment Inventory_26 August 2021.xlsx XLSX spreadsheet
FIS_PWS_Sect J_ATCH-05_ELINs_FIS-ENV_Region 6_20210826.xlsx XLSX spreadsheet
Show all 50

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

63rd Readiness Division Fire Alarm Record of Inspection and Testing

FACID

Building Number

Date of Inspection

Fire Alarm Annual Inspection & Testing Report Report of Annual Inspection, Testing & Maintenance of Fire Sprinkler Systems

ONE REPORT SHALL BE COMPLETED FOR EACH BUILDING

Fire Protec on Systems

Comments/Deficiencies

Fire Alarm System Assessment Green Yellow Red

Fire Alarm system appears to operate as designed—Color Code (Color code is based on the following criteria: Green = No deficiencies or only noncritical deficiencies; Yellow = System operates but has critical deficiencies; Red = System is inoperable

Complete the remainder of this page once inspection is complete.

Fire Alarm Information

Control Unit Manufacturer: Model Number: Location: Software Revision:

SLCs/IDCs Max #: # Utilized: Style/Class: NAC

Circuits Max #: # Utilized: Style/Class:

Primary Power

Voltage: Amps: Overcurrent Protection Type: Amps: Disconnecting Means Location:

Battery 1 Voltage: Amps: Mfr Year: Load Test

Battery 1 VDC: Ah: Temp (F):

Result of Battery 1 & 2

Battery 2 Voltage: Amps: Mfr Year: VDC: Ah: Temp (F):

Pass Fail Replaced

Secondary Power

Other Power Present Description Yes No

Load Test Battery 2

Mass Notification System Y N/A N

Building has a Mass Notification System (if yes, complete the Mass Notification Supplementary Record of Inspection and Testing)

Notifications are made Yes No Who Time

Monitoring Entity

Building Occupants

Building Management

AHJ Notified of Impairments

Notifications Prior Made to Any Testing

Alarm Initiating & Notification Device Count *See Notification & Initiating Appliances Supplementary Record of Inspection and Testing for Specific Results Circuit

Style Quantity of Devices

Tested

Manual Pull Station

Ion Smoke Detectors

Photo Smoke Detector

Duct Detectors

Heat Detectors

Carbon Monoxide Detectors

Waterflow Switches

Supervisory Switches Notification Devices (audio, visual, combo, etc)

Alarm Verification Feature is:

Type Visual Functional Results

Control Unit Pass Fail N/A

Lamps/LEDs/LCDs

Fuses

Trouble Signals

Disconnect Switches

Ground-Fault Monitoring

Disconnect Switches

Ground-Fault Monitoring

System Tests And Inspections

Supervision

Local Annunciator

Remote Annunciators

Power Extender Panels

Isolation modules

Other (specify)

N/A

Control Unit Power Supplies Type Visual Functional N/A Results

120-volt Power Pass Fail N/A

Generator or UPS

Battery Condition

Load Voltage

Discharge Test

Charger Test

Supervising Station Monitoring Type Visual Functional N/A Results

Alarm Signal Pass Fail N/A

Alarm Restoration

Trouble Signal

Trouble Restoration

Supervisory Signal

Supervisory Restoration

Time (sec)

Auxiliary Functions Type Visual Functional Comments

Door-releasing devices

Fan Shutdown Smoke Management/ Smoke Control

Smoke Damper Operation

Smoke Sutter Release

Door Unlocking

Elevator Recall

Elevator Shunt Trip

MNS Override of FA Sig-nals

Other (Specify)

N/A

Monitored Systems Type Visual Functional N/A Comments

Engine-driven Generator

Fire Pump

Kitchen Hood System

Dry Chemical System(s)

Notifications That Testing Is Complete

Notifications are made Yes No Who Time

Monitoring Entity Building Management

Inspector's Information I state that the information on this form is correct at the time and place of my inspection, and that all equipment tested at this time was left in operating condition upon completion of this inspection except as noted in the Comments.

Inspected By Inspector License:

Signature of Inspector Date