AM04 DRAWINGS.pdf

PDF 2 MB Posted

Attached to
Aircraft Maintenance Unit (AMU) and Weapons Hangar, Hurlburt Field, FL
Solicitation number
W9127820R0104
Issued by

About this file

This solicitation is for the construction of a new 105,041 square-foot maintenance hangar, aircraft maintenance unit with shops, and weapons shop at Hurlburt Field, Florida. Supporting facilities include utilities, pavements, site improvements, communications, and demolition of seven existing buildings. Special site conditions require excavation, fill, stabilization and realignment of existing utilities/communications. Airfield pavements are required to provide access to the hangar. The work includes a reinforced concrete foundation and floor slab, steel structure, masonry walls and standing seam metal roof, environmental control, fire detection and protection, and mass notification system. The solicitation number is W9127820R0104 and was issued by the Department of the Army Corps of Engineers Engineering District Mobile.

View the file

Other files

File Type Posted
AM05 DRAWINGS.pdf PDF
AM05.pdf PDF
AM04.pdf PDF
AM03.pdf PDF
Minutes-Pre-Bid site visit.pdf PDF
Minutes-Pre-Bid demo site visit.pdf PDF
AM03 DRAWINGS.pdf PDF
AM02.pdf PDF
APPENDIX F- As Builts of Demo Buildings- 1 of 3.zip ZIP file
APPENDIX F- As Builts of Demo Buildings- 2 of 3.zip ZIP file
APPENDIX F- As Builts of Demo Buildings- 3 of 3.zip ZIP file
AM01 Drawings.pdf PDF
AM01.pdf PDF
RTA DRAWINGS VOL 2.pdf PDF
VOL3.PDF PDF
VOL2.PDF PDF
VOL4.PDF PDF
RTA DRAWINGS VOL 1.pdf PDF
VOL6.PDF PDF
VOL1.PDF PDF
VOL5.PDF PDF
EM 385-1-1.pdf PDF
RTA DRAWINGS VOL 3.pdf PDF
Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US Army Corps of Engineers

MOBILE DISTRICT

109 SAINT JOSEPH STREET

MOBILE AL 36602

FTEV153009 SOF AMU &

WEAPONS HANGAR FACILITY

HURLBURT FIELD, FLORIDA

OKALOOSA COUNTY

AUGUST 2020

MOBILE DISTRICT PROJECT CODE: MEF20004

SOLICITATION NUMBER: W9127820R0104

AMENDMENT NO. 0004

1. GENERAL:

A. THESE NOTES, AND OTHER DRAWING NOTES CONTAINED WITHIN, ARE PROVIDED TO MEET

SPECIFIC REQUIREMENTS AND TO SUPPLEMENT THE CONTRACT SPECIFICATIONS. THESE NOTES

NEITHER REPLACE NOR OVERRIDE THE PROVISIONS AND REQUIREMENTS OF THE CONTRACT

SPECIFICATIONS.

B. CONTRACTOR SHALL COORDINATE ALL STRUCTURAL WORK WITH WORK SHOWN ON ALL OTHER

DRAWINGS.

C. CONTRACTOR SHALL VERIFY ALL DIMENSIONS OF EXISTING CONSTRUCTION AND REPORT ANY

DISCREPANCIES FROM THE CONTRACT DRAWINGS TO THE CONTRACTING OFFICER'S

REPRESENTATIVE PRIOR TO COMMENCING WITH WORK. SCALING OF WORKING DIMENSIONS

FROM THE STRUCTURAL DRAWINGS IS PROHIBITED.

D. CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE.

CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODS OF CONSTRUCTION

INCLUDING, BUT NOT LIMITED TO, SHORING AND TEMPORARY BRACING. CONTRACTOR SHALL

UNDERTAKE ALL NECESSARY MEASURES TO ENSURE SAFETY OF ALL PERSONS AND

STRUCTURES AT THE SITE AND ADJACENT TO THE SITE. VISITS TO THE SITE BY THE

CONTRACTING OFFICER'S REPRESENTATIVE SHALL NOT RELIEVE THE CONTRACTOR OF SUCH

RESPONSIBILITY.

E. IF CERTAIN FEATURES ARE NOT FULLY SHOWN OR CALLED FOR ON THE CONTRACT DRAWINGS

OR SPECIFICATIONS, THEIR CONSTRUCTION SHALL BE OF THE SAME CHARACTER AS FOR

SIMILAR CONDITIONS THAT ARE SHOWN OR CALLED FOR, WITH THE APPROVAL OF THE

CONTRACTING OFFICER'S REPRESENTATIVE. WHERE SECTIONS VARY, CONTRACTOR SHALL

PROVIDE FOR SMOOTH TRANSITIONS BETWEEN THEM, UNLESS NOTED OTHERWISE.

F. ALL PRODUCTS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS' WRITTEN

INSTRUCTIONS AND RECOMMENDATIONS, UNLESS NOTED OTHERWISE.

G. ELEVATION 100' - 0" CORRESPONDS TO NAVD 88 ELEVATION 36.67'.

2. DESIGN STANDARDS

A. PRINCIPAL CODE OF RECORD: INTERNATIONAL BUILDING CODE 2015, AS MODIFIED BY THE

FOLLOWING CRITERIA: UNITED FACILITIES CRITERIA: 1-200-01, 3-301-01, 3-310-04, 4-0101-01, 4-211-01.

B. ASCE 7, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, 2010.

C. ACI 318, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, 2014.

D. ACI 530/ASCE 5/TMS 402, BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES, 2013.

E. AISC 325, STEEL CONSTRUCTION MANUAL, 14th EDITION, 2011.

F. AISC 360-10, SPECIFICATION FOR STRUCTURAL STEEL BUIDLINGS, 14th EDITION, 2010.

G. AISI COLD-FORMED STEEL DESIGN MANUAL, 2013.

5. GEOTECHNICAL INFORMATION

A. SOURCE: TERRACON CONSULTANTS, INC. PENSACOLA, FL (JULY 17, 2019)

B. SITE PREPARATION

1. EXCAVATION, FILL, AND BACKFILL SHALL BE IN ACCORDANCE WITH THE CONTRACT

DRAWINGS AND SPECIFICATIONS, DIVISION 31.

2. CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER WHEN LOOSE OR SOFT SOILS

ARE EXPOSED WHERE SLABS, MATS, OR FOOTINGS ARE TO BE PLACED SO THAT A

DETERMINATION MAY BE MADE REGARDING IMPROVEMENT OF THIS POTENTIALLY

UNDESIRABLE CONDITION.

C. SOIL CHARACTERISTICS

1. UNIT WEIGHT: 100 PCF

2. WATER TABLE DEPTH: ~9FT BELOW FINISH FLOOR

D. SLAB, MAT, AND FOOTING DESIGN PARAMETERS

1. MODULUS OF SUBGRADE REACTION: 150 PCI.

2. ALLOWABLE BEARING CAPACITIES

a. GRAVITY LOADS: 3000 PSF.

b. TRANSIENT LOADS: 4000 PSF.

3. CONCRETE-SOIL COEFFICIENT OF FRICTION: 0.35.

4. MINIMUM STABILITY FACTORS OF SAFETY (0.6DL+0.6WL)

a. OVERTURNING: 1.0.

b. UPLIFT: 1.0.

c. SLIDING: 1.0.

3. SPECIAL INSPECTIONS

A. STATEMENT OF SPECIAL INSPECTIONS

1. SEE SPECIFICATION 01 45 35

4. DESIGN LOADS

A. RISK CATEGORY: III (HANGAR), II (ADMIN/SHOP).

B. LIVE LOADS:

1. FLOOR LIVE LOAD:

a. 100 PSF (ADMIN = 6IN SLAB)

b. 250 PSF (SHOP = 8IN SLAB, SNC BAY/HANGAR = 15IN SLAB).

2. ROOF LIVE LOAD: 20 PSF NONREDUCIBLE, CONCENTRATED LOAD OF 1000 POUNDS

(CONCURRENT WITH UNIFORM LIVE LOAD).

C. COLLATERAL LOADS: 10 PSF, 25 PSF PUMP/FOAM ROOM, 25 PSF MECHANICAL EQUIPMENT

D. EQUIPMENT LOADS

1. AS INDICATED FOR EQUIPMENT WEIGHING IN EXCESS OF 1000 LBS. FRAMING AND

FOUNDATIONS ARE DESIGNED FOR EQUIPMENT WHICH SATISFIES THE CONTRACT

SPECIFICATIONS.

2. IF EQUIPMENT FURNISHED IS HEAVIER THAN THE WEIGHTS INDICATED, OR REQUIRES

STRUCTURAL CHANGES FOR ANY OTHER REASON, CONTRACTOR SHALL PROVIDE

ENGINEERING DESIGN CALCULATIONS AND ADDITIONAL STRUCTURAL WORK NECESSARY TO

SUPPORT ALL LOADS IN ACCORDANCE WITH THE DESIGN STANDARDS SPECIFIED ABOVE, AT

NO ADDITIONAL COST TO THE OWNER AND WITH NO INCREASE IN CONTRACT TIME.

E. WHEEL LOADS

1. HANGAR

a. AC130J AIRCRAFT WHEEL AND JACK LOADS

b. GROVE YB5515 ENGINE CRANE

c. MHU-83 AMMUNITION LOADER

d. MODEL MB-2 TOW TRACTOR

e. K LOADER

2. SHOP (8IN SLAB)

a. 3 TON FORKLIFT

3. SNC BAY (15IN SLAB)

a. K LOADER

F. MONORAIL CRANE LOADS

1. 7 TON AT HANGAR BAY

2. 3 TON AT GUN MAINTENANCE SHOP

G. SNOW LOAD

1. GROUND SNOW LOAD: 0 PSF.

H. WIND LOAD

1. ULTIMATE DESIGN WIND SPEED: 157 MPH (HANGAR), 145 MPH (ADMIN/SHOP) 3-SECOND GUST.

2. NOMINAL DESIGN WIND SPEED: 122 MPH (HANGAR), 112 MPH (ADMIN/SHOP) 3-SECOND GUST.

3. EXPOSURE CATEGORY: C.

4. BUILDING CONDITION:

a. HANGAR & SNC BAY: PARTIALLY ENCLOSED.

b. ADMIN/SHOP: ENCLOSED

5. DESIGN PRESSURES FOR COMPONENTS AND CLADDING ARE INDICATED ON

DRAWING S-004 - S-007.

6. HANGAR DOORS SHALL BE CLOSED AT 60 MPH.

J. SEISMIC LOAD

1. MAXIMUM CONSIDERED EARTHQUAKE SPECTRAL RESPONSE ACCELERATIONS Ss = 0.080, S1 = 0.05.

2. DESIGN EARTHQUAKE SPECTRAL RESPONSE ACCELERATIONS Sds = 0.085, Sd1 = 0.08.

3. RISK CATEGORY: III (HANGAR), II (ADMIN/SHOP).

4. SITE CLASS: D.

5. SEISMIC DESIGN CATEGORY: B.

6. BASIC SEISMIC FORCE RESISTING SYSTEM: STEEL SYSTEMS NOT SPECIFICALLY DETAILED

FOR SEISMIC RESISTANCE (HANGAR), ORDINARY REINFORCED MASONRY SHEAR WALLS

(ADMIN/SHOP).

7. RESPONSE MODIFICATION COEFFICIENT: R = 3 (HANGAR), R = 2 (ADMIN/SHOP).

8. SEISMIC RESPONSE COEFFICIENT: Cs = 0.0356 (HANGAR), Cs = 0.0427 (ADMIN/SHOP)

9. DESIGN BASE SHEAR:

105 KIPS (HANGAR), 707 KIPS (ADMIN/SHOP).

10. ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE.

K. FALL PROTECTION SYSTEM

1. CAPACITY: 3 USERS AT EACH FIXED ANCHOR POSITION (3 x 13 = 39 TOTAL).

2. SEE SPECIFICATION SECTION 11 01 50.

L. THERMAL DESIGN TEMPERATURE CHANGE: 28 DEGREES F (HANGAR), 16 DEGREES F (ADMIN/SHOP)

6. MATERIALS: SEE THE CONTRACT SPECIFICATIONS FOR COMPLETE REQUIREMENTS AND COMPLY

WITH ALL APPLICABLE OSHA REGULATIONS

A. REINFORCED CONCRETE:

1. REINFORCED CONCRETE SHALL BE PREPARED AND PLACED IN ACCORDANCE WITH ACI

MANUAL OF CONCRETE PRACTICE.

2. CONCRETE

a. UNLESS NOTED OTHERWISE: MINIMUM 28-DAY COMPRESSIVE STRENGTH f'c = 4000 PSI, NORMAL WEIGHT.

b. FOUNDATIONS: MINIMUM 28-DAY COMPRESSIVE STRENGTH f'c = 4000 PSI, NORMAL WEIGHT.

c. SLABS ON GRADE: MINIMUM 28-DAY COMPRESSIVE STRENGTH f'c = 5000 PSI, NORMAL WEIGHT, WITH A MINIMUM 28-DAY FLEXURAL STRENGTH OF 650 PSI.

d. INTERIOR SLABS WITH TROWEL FINISH SHALL NOT HAVE AIR ENTRAINMENT.

e. HANGAR SLAB CONCRETE SHALL COMPLY WITH SPECIFICATION 32 13 14.13.

3. FORMWORK

a. CONTRACTOR SHALL BE RESPONSIBLE FOR DESIGN, ENGINEERING, STRUCTURAL

ADEQUACY, AND CONSTRUCTION OF ALL CONCRETE FORMWORK IN ACCORDANCE

WITH THE CONTRACT SPECIFICATIONS.

b. COORDINATE ALL CONCRETE WORK WITH THE PLACEMENT OF PIPING, INSERTS, FLOOR DRAINS, AND OTHER EMBEDDED ITEMS INDICATED ON THE CONTRACT

DRAWINGS OR IN THE CONTRACT SPECIFICATIONS.

c. ALL NEW OR EXISTING PIPING OR UTILITIES PASSING THROUGH NEW CONCRETE

SHALL BE SLEEVED 1/2" CLEAR ALL AROUND, UNLESS NOTED OTHERWISE. SEE

OTHER DISCIPLINE DRAWINGS FOR SLEEVE DETAILS. CONTRACTOR SHALL PROVIDE

MEASURES TO ENSURE THAT SLEEVES REMAIN FREE OF DEBRIS AND WATER

DURING CONSTRUCTION.

d. PROVIDE 3/4" CHAMFER STRIPS ON ALL EDGES OF EXPOSED CONCRETE, UNLESS

NOTED OTHERWISE.

e. COLUMN AND WALL FOOTINGS SHALL NOT BE EARTH-FORMED.

f. FOUNDATION STEMWALLS EXPOSED ABOVE SLAB/GRADE SHALL MEET SF-3.0 FINISH.

4. REINFORCING STEEL

a. BARS: ASTM A615 GRADE 60/ASTM A706 GRADE 60.

b. ALL CONCRETE SHALL BE REINFORCED UNLESS SPECIFICALLY MARKED "NOT

REINFORCED" OR "UNREINFORCED".

c. CONTRACTOR SHALL DETAIL AND PLACE ALL REINFORCEMENT IN ACCORDANCE

WITH ACI SP-66, ACI 301, ACI 318, AND CRSI MANUAL OF STANDARD PRACTICE.

d. MINIMUM CONCRETE CLEAR COVER OVER REINFORCEMENT SHALL BE AS

FOLLOWS, UNLESS NOTED OTHERWISE:

(1) CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3".

(2) CONCRETE EXPOSED TO EARTH OR WEATHER: 3".

(3) CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND:

SLABS AND WALLS - 1"; BEAMS AND COLUMNS, PRIMARY REINFORCEMENT,

TIES, STIRRUPS, SPIRALS - 2".

e. SEE STANDARD CONCRETE DETAILS FOR DEVELOPMENT AND SPLICE LENGTH.

f. PROVIDE ADDITIONAL REINFORCEMENT AT ALL OPENINGS AND CORNER BARS AT ALL

INTERSECTING GRADE BEAMS, WALLS, AND CURBS IN ACCORDANCE WITH THE

STANDARD DETAILS,UNLESS NOTED OTHERWISE.

5. JOINTS

a. LOCATE ALL CONSTRUCTION, CONTRACTION, ISOLATION, EXPANSION, AND OTHER

JOINTS AS INDICATED OR SPECIFIED, OR OTHERWISE APPROVED BY THE

CONTRACTING OFFICER'S REPRESENTATIVE.

b. SURFACES OF ALL HORIZONTAL AND VERTICAL CONSTRUCTION JOINTS SHALL BE

CLEANED OF LAITANCE AND SHALL EXPOSE CLEAN COARSE AGGREGATE SOLIDLY

EMBEDDED IN MORTAR MIX. JUST PRIOR TO DEPOSITING CONCRETE, SURFACE OF

CONSTRUCTION JOINT SHALL BE THOROUGHLY CLEANED AND WETTED.

c. THESE PROVISIONS SHALL ALSO APPLY WHEN NEW CONCRETE IS PLACED AGAINST

EXISTING CONCRETE. IN ADDITION, EXISTING CONCRETE SURFACE SHALL BE

ADEQUATELY PREPARED BY APPLICATION OF A BONDING AGENT.

d. PROVIDE WATERSTOPS AT CONCRETE JOINTS WHERE INDICATED ON THE

CONTRACT DRAWINGS. ALL WATERSTOPS SHALL BE JET FUEL RESISTANT TYPE,

UNLESS NOTED OTHERWISE.

B. REINFORCED MASONRY

1. GENERAL

a. ENGINEERED MASONRY IS DESIGNED IN ACCORDANCE WITH "BUILDING CODE

REQUIREMENTS FOR MASONRY STRUCTURES" ACI 530/ ASCE 5/ TMS 402, 2013.

b. UNITS: ASTM C90, MEDIUM WEIGHT EXCEPT OVEN-DRY WEIGHT SHALL NOT BE LESS

THAN 105 PCF. COMPRESSIVE STRENGTH = 2000 PSI MINIMUM.

c. MORTAR: ASTM C270 TYPE S, PROPORTION METHOD ASSEMBLY/PRISM MINIMUM COMPRESSIVE STRENGTH, f'm = 2000 PSI

d. GROUT: ASTM C476, MINIMUM COMPRESSIVE STRENGTH = 2000 PSI, SLUMP = 8" TO 11".

e. REINFORCING STEEL BARS: ASTM 615 GRADE 60/ASTM A706 GRADE 60.

1. GENERAL: (CONTINUED)

f. FULLY GROUT ALL CELLS. PROVIDE MASONRY UNITS WITH MINIMUM SPACE IN CELLS

TO RECIEVE GROUT OF 3"X3" AND ALIGN THESE CELLS TO PROVIDE UNOBSTRUCTED

OPENINGS.

g. CONSOLIDATE GROUT IN ASSEMBLED WALLS BY MECHANICAL VIBRATION AT THE

TIME OF PLACEMENT. RECONSOLIDATE GROUT BY MECHANICAL VIBRATION AFTER

INITIAL WATER LOSS AND SETTLEMENT HAS OCCURRED.

h. PLACE GROUT WITHIN 1 1/2 HOURS AFTER ADDING MIX-DESIGNED WATER AND PRIOR

TO INITIAL SET. GROUT CONTINUOUSLY BETWEEN CONTROL JOINTS USING POUR

HEIGHTS NOT EXCEEDING 12 FT AND LIFTS NOT EXCEEDING 5 FT, WITH NO

INTERRUPTIONS EXCEEDING 1 HOUR.

j. USE FULL CONTACT LAP SPLICES FOR REINFORCING STEEL IN CMU

WALLS AS FOLLOWS:

#4 BARS: MINIMUM 25 INCHES

#5 BARS: MINIMUM 40 INCHES

#6 BARS: MINIMUM 54 INCHES

k. THREADED MECHANICAL COUPLERS SHALL BE USED IN LIEU OF FULL CONTACT LAP

SPLICES WHERE 2 REINFORCING BARS ARE REQUIRED IN ONE CMU CELL AND AT WALL

INTERSECTIONS.

l. MINIMUM CLEAR DISTANCE TO ANY FACE OF MASONRY UNIT OR FORMED SURFACE: 1/2".

m. USE RUNNING BOND PATTERN, UNLESS INDICATED OTHERWISE.

n. PROVIDE LATERAL SUPPORT AT THE TOP OF WALLS, UNLESS INDICATED OTHERWISE.

o. FULL MORTAR BEDDING SHALL BE EMPLOYED WHEN CONSTRUCTING PARTIALLY

GROUTED MASONRY WALLS.

p. ARCHITECTURAL COMPONENTS SUCH AS SEALANT, FLASHING, ETC, ARE NOT

ILLUSTRATED IN DETAILS. SEE ARCHITECTURAL DRAWINGS FOR THESE COMPONENTS.

q. SEE SPECIFICATION SECTION 01 45 35 FOR MASONRY SPECIAL INSPECTION

REQUIRMENTS.

r. SEE ARCHITECTURAL DRAWINGS FOR BRICK EXPANSION JOINT LOCATIONS IF

APPLICABLE FOR PROJECT.

s. MASONRY UNITS SHALL NOT BE FIELD MODIFIED UNLESS INTENDED TO BE MODIFIED.

t. U SHAPED BOND BEAMS SHALL BE USED AT WALL OPENING HEAD LOCATIONS.

u. KNOCK OUT BOND BEAMS SHALL BE USED AT WALL BOND BEAM LOCATIONS.

v. OPEN END MASONRY UNITS MAY BE USED TO FACILITATE WALL CONSTRUCTION.

w. DOUBLE OPEN END UNITS MAY BE USED WHEN WALL IS SOLID GROUTED.

x. CONTRACTOR RESPONSIBLE FOR ALL TEMPORARY WALL BRACING DURING

CONSTRUCTION.

2. VERTICAL REINFORCING

a. UNLESS NOTED OTHERWISE, PROVIDE THE FOLLOWING:

(1) EXTERIOR NON STRUCTURAL 8" CMU = 10FT TALL: (1) #6 @ 40" OC

(2) EXTERIOR NON STRUCTURAL 8" CMU > 10FT TALL: (2) #5 @ 8" OC

(3) INTERIOR NON STRUCTURAL 8"/12" CMU: (1) #6 @ 24" OC

(4) EXTERIOR STRUCTURAL 12" CMU: (1) #6 @ 24" OC

(5) INTERIOR STRUCTURAL 12" CMU: (1) #6 @ 24" OC

(6) INTERIOR STRUCTURAL 8" CMU: (1) #6 @ 40" OC

(7) ALL STRUCTURAL 12" CMU AT SNC BAY: (2) #6 @ 8" OC

b. PROVIDE ADDITIONAL VERTICAL REINFORCEMENT AT EACH SIDE OF CONTROL JOINTS

AND AT INTERSECTION OF WALLS. PROVIDE ADDITIONAL VERTICAL REINFORCMENT AT

EACH SIDE OF ALL MASONRY OPENINGS GREATER THAN 10" IN WIDTH, SEE TYPICAL

MASONRY JAMB DETAILS. ADDED VERTICAL REINFORCEMENT SHALL BE CONTINUOUS

FOR THE FULL HEIGHT OF WALL UNO. SEE ADD BAR DETAIL.

c. PROVIDE FOUNDATION DOWEL SAME SIZE AND LOCATION AS VERTICAL BARS IN THE

WALL ABOVE. DOWELS SHALL BE LOCATED AT EACH VERTICAL WALL REINFORCEMENT.

DOWELS SHALL BE CAST A MINIMUM OF 2" GREATER THAN REQUIRED LAP SPLICE.

AT THICKENED SLABS, EXTEND DOWELS TO WITHIN 2" OF THE BOTTOM OF SLAB AND

PROVIDE A STANDARD 90° HOOK.

d. EXTEND ALL VERTICAL BARS FROM THE BOTTOM COURSE THROUGH THE TOP MOST

BOND BEAM.

3. HORIZONTAL REINFORCING

a. CONSTRUCT BOND BEAMS USING (2) - #5 HORIZONTAL UNO (12" CMU), AND (2) - #4

HORIZONTAL (8" CMU).

b. PROVIDE BOND BEAMS AT 2' - 0" MAX VERTICAL SPACING WHERE NOT INDICATED

ON DRAWING, OR AT OTHER ELEVATIONS AS INDICATED.

c. PROVIDE BOND BEAM AT THE BOTTOM-MOST COURSE AND PROVIDE 2 COURSE BOND

BEAM AT THE TOP-MOST OR AT THE SECOND FROM TOP-MOST COURSES AS PRACTICAL

TO PROVIDE CONT BEAM.

d. PROVIDE BOND BEAM BELOW ALL MASONRY OPENINGS AND EXTEND A MINIMUM OF

24" BEYOND EACH SIDE OF OPENING.

e. BOND BEAM REINFORCEMENT SHALL BE CONTINUOUS AT ALL LOCATIONS.

4. EXPANSION / CONTRACTION JOINTS

a. PROVIDE A MINIMUM 3" GAP BETWEEN TOP OF NON STRUCTURAL CMU WALLS AND

THE BOTTOM OF THE STRUCTURE.

b. WHERE NON STRUCTURAL WALLS INTERSECT STRUCTURAL WALLS, PROVIDE

STRUCUTRAL SEPARATION OF 1" GAP TO ACCOMODATE BUILDING DRIFT.

c. PROVIDE CONTINUOUS COMPRESSIBLE FILLER OR FIRE SAFEING INSULATION AS

REQUIRED (FULL WIDTH AND FULL LENGTH) OF THE SAME THICKNESS AS THE JOINT.

d. STRUCTURAL MASONRY HAS BEEN DESIGNED TO MEET THE AREA OF REINFORCEMENT

STEEL REQUIRED BY THE NATIONAL CONCRETE MASONRY ASSOCIATION (NCMA) TEK

10-3 ALTERNATIVE ENGINEERED METHOD TO LIMIT CRACK WIDTH WITHOUT THE USE OF

CONTROL JOINTS. DO NOT INSTALL CONTROL JOINTS IN STRUCTURAL MASONRY.

5. TOP CLIP SUPPORTS:

a. PROVIDE BENT PLATE SUPPORTS OR DIAGONAL BRACING SUPPORT AT EVERY

VERTICAL REINFORCEMENT LOCATION AND AS LISTED BELOW, EXCEPT AT LOAD-

BEARING WALLS.

b. LOCATE AT DISCONTINUOUS ENDS OF WALLS, AT EACH SIDE OF INTERMEDIATE

CONTROL JOINTS, AND AT EACH SIDE ABOVE OPENINGS WIDER THAN 6' - 6".

c. TWO CELLS UNDER EACH TOP CLIP SHALL BE FULLY GROUTED. SOLID MASONRY

UNITS MAY BE PROVIDED.

6. LINTELS:

a. PROVIDE MASONRY LINTELS ABOVE OPENINGS IN MASONRY WALLS AS REQUIRED PER

DRAWINGS.

GENERAL NOTES:

M. STRUCTURAL SEPARATION

1. STRUCTURAL SEPARATION JOINTS ARE LOCATED AT THE FOLLOWING LOCATIONS:

a. 4" STRUCTURAL SEPARATION BETWEEN STEEL STRUCTURE (HANGAR) AND

REINFORCED MASONRY STRUCTURE (ADMIN/SHOPS). ANTICIPATED MOVEMENT +/- 2"

BETWEEN STEEL STRUCTURE AND REINFORCED MASONRY STRUCTURE.

b. COMPONENTS CROSSING THESE JOINTS SHALL ACCOMMODATE THIS MOVEMENT

H U

R L

B U

R T

F

IE

L D

F

L O

R

ID

A H

A N

G A

R

A M

U P

R O

J E

C T

N O

F

T E

V

M O

B

IL

E D

IS

T

R

IC

T M

O B

IL

E

A

L A

B A

M A

Mobile District

US Army Corps of

Engineers ®

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R N

O

U S

A R

M Y

C O

R P

S O

F

E N

G

IN

E E

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

FILE:

DATE:

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y

M O

B U

R N

S

M c D

O N

N E

L L

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S B

M T

B Y

P L

O T

S C

A L E

S

IZ

E x

F

IL

E N

A M

E

C K

D B

Y

P L

O T

D A

T E

D A

T E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

P R

O J E

C T

N U

M B

E R

C A

D D

C O

D E

J U

L Y

W

-2

-R

-0

F T

E V

M E

F

JU

L

Y

A

M A

S H

E K

AMENDMENT NO. 0004

12/11/2020 3:24:56 PM

/4

'-0

P

M A

N

IS

Z . A

D A

M S

S-001-0004

S -0

-0

S-001

G E

N E

R A

L N

O T

E S

A

M E

N D

/1

/2

U

P D

A T

E D

H A

N G

A R

S L A

B C

O

C

CONTRACTION JOINT (CTJ) ADMIN/SHOP

CONSTRUCTION JOINT (CJ) ADMIN/SHOP

VAPOR BARRIER

VAPOR BARRIER

H

H

/4 SEALED (SAWED)

WIDTH PER SCHEDULE,

SEALED (FORMED)

WIDTH PER SCHEDULE,

H /2

H

DOWELS - PAINT AND

GREASE ONE END -

SEE SCHEDULE

D4

S-501

D4

S-501

NOT TO SCALE

SLAB ON GRADE JOINTS

SLAB SCHEDULE

SLAB

THICKNESS H

DIA X LENGTH

(SMOOTH BARS)

SPACING

WIDTH DEPTH OF

SAWCUT

DOWELS JOINT

6"

8"

3/4" X 16" 12" 1/8" TO 1/4" H/4 +/- 1/2"

1" X 16" 12" 1/8" TO 1/4" H/4 +/- 1/2"

1. START DOWELS NO CLOSER THAN 2' - 0" FROM SLAB JOINTS.

2. COORDINATE JOINTS WITH DIVISION 07 SPECS AND FLOOR FINISH REQUIREMENTS.

3. SEE PLANS FOR JOINT LAYOUT.

H /2

SLAB REINFORCEMENT

AS INDICATED

DOWELS - PAINT AND

GREASE ON END -

SEE SCHEDULE

SLAB REINFORCEMENT

AS INDICATED

15" 1 1/4" X 20" 15" 3/8" 3"

3" MAX

H /4

3" MAX

H

U N

O

.5

H

VAPOR

BARRIER

SEE SLAB JOINT

DETAIL

NOTE: DISCONTINUE REINFORCEMENT AT JOINT, UNO

SLOPE 1:10

EXPANSION JOINT (EJ-H) AT HANGAR SLAB EDGE

3/8" EXPANSION

JOINT MATERIAL

2 LAYERS 30# FELT

EJ IJ

TYPICAL ISOLATION JOINTTYPICAL EXPANSION JOINT

NOTES:

4' - 0"

(48) #7 VERT

EQ SPA

#5 TIES

S

P A

O

C

S

P A

O C

LIGHT POLE

AND ANCHORS

PER POLE

SUPPLIER

3/4" CHAMFER

EXPOSED EDGES

LIGHT POLE FOUNDATION NOTES:

1. ALLOWABLE POLE SHEAR = 12 KIP

2. ALLOWABLE POLE MOMENT = 540 KIP-FT

3. ALLOWABLE POLE DEAD LOAD = 10 KIP

4. POLE LOADS SHALL BE REVIEWED PRIOR TO

FOUNDATION CONSTRUCTION.

65' - 0" TALL HIGH MAST POLE FOUNDATION

30' - 0" TALL PARKING POLE FOUNDATION

3/4" CHAMFER

EXPOSED EDGES 3' - 0" Ø

#4 TIES

(24) - #6

EQ SP

S

P A

O

C

S

P A

O C

8'-0" SQR

NOTES:

T/GRADE EL 99' - 4"

LIGHT POLE

AND ANCHORS

PER POLE

SUPPLIER

SECTION SECTION

LIGHT POLE FOUNDATION NOTES:

1. ALLOWABLE POLE SHEAR = 1.7 KIP

2. ALLOWABLE POLE MOMENT = 30 KIP-FT

3. ALLOWABLE POLE DEAD LOAD = 0.5 KIP

4. POLE LOADS SHALL BE REVIEWED

PRIOR TO FOUNDATION CONSTRUCTION.

5. SEE CIVIL/ELEC DRAWINGS FOR

LOCATION.

NOTES:

SEE PLAN

V A

R

IE

S

T/GRADE EL 100' - 0"

T/PED EL 103' - 0"

T/PED EL 103' - 0"

#5 @ 6" OC EW TB

CONSTRUCTION

JOINT, TYP

T/WALL EL 110' - 0"

#5 @ 12" OC,

EW, TYP

#5 @ 12" OC,

EW, TYP

2' - 8" 8" 2' - 8"

#5 @ 12"

OC, EW,TYP

#5 @ 6" OC,

EW, BOT

METAL COPING,

SEE SPCS

8" SPLIT FACE CMU,

#5 @ 24" OC VERT,

(2) - #5 @ 24" OC HORIZ,

SOLID GROUT WALL

#5 @ 12"

OC, EW,TOP

T/GRADE EL 100' - 0"

#5 @ 6" OC,

EW, BOT

TYPICAL DETAILS AT DOORWAY LOCATIONS

NOT TO SCALE

SLAB REINFORCING

PER PLAN

(3) - #4

#4 @ 12" OC

M

IN

SEE PLANS

FOR STEMWALL

SECTION - MAN DOORS

SEE NOTE 9/S-110

CIVIL

PAVEMENT/

SIDEWALK/

SLAB

/2

M

A X

6" MAX

(3) - #4

#4 @ 12" OC

M

IN

SEE PLANS

FOR STEMWALL

VAPOR BARRIER

SHALL EXTEND

OVER STEM WALL

SECTION - OVERHEAD DOORS

SEE NOTE 18/S-110

(SLOPE 1/2" MAX)

PER OH DOOR REQUIREMENTS

M A

X

/2

GALV L2X2X1/4 WITH

1/2"Ø X 4" LONG

HEADED STUDS

CIVIL PAVEMENT/

SIDEWALK/SLAB 1

M

IN

H A

N G

A R

M

IN

S H

O P

S

M

IN

H

A N

G A

R

M

IN

S

H O

P S

VAPOR BARRIER

SHALL EXTEND

OVER STEM WALL

PUMP, SEE FIRE

SUPPRESION DWGS,

ANCHORAGE BY

EQUIP SUPPLIER

CL PUMP

#5 @ 9" OC

VERT, EF

#4 TIES @ 2", 5", 8",

11" FROM TOP,

REST AT 9" OC MAX

#5 @ 12"

OC, EW, TOP

* CONTRACTOR SHALL

COORDINATE

WITH ACTUAL

EQUIP FURNISHED

EJ, TYP

1' - 0"1' - 0"

1' - 0" * 1' - 0" *

#5 @ 6"

OC, EW, BOT

#5 @ 6"

OC, EW, BOT

H U

R L

B U

R T

F

IE

L D

F

L O

R

ID

A H

A N

G A

R

A M

U P

R O

J E

C T

N O

F

T E

V

M O

B

IL

E D

IS

T

R

IC

T M

O B

IL

E

A

L A

B A

M A

Mobile District

US Army Corps of

Engineers ®

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R N

O

U S

A R

M Y

C O

R P

S

G

IN

E E

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

FILE:

DATE:

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y

M O

B U

R N

S

M c D

O N

N E

L L

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S B

M T

B Y

P L

O T

S C

A L E

S

IZ

E x

F

IL

E N

A M

E

C K

D B

Y

P L

O T

D A

T E

D A

T E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

P R

O J E

C T

N U

M B

E R

C A

D D

C O

D E

J U

L Y

W

-2

-R

-0

F T

E V

M E

F

JU

LY

, 2

A

. M A

S H

E K

AMENDMENT NO. 0004

12/11/2020 3:24:59 PM

A s in di ca te d

P . M

A N

IS

Z . A

D A

M S

S-502-0004

S -5

-0

S-502

S T

A N

D A

R D

C O

N C

R E

T E

D E

T A

IL

S

SCALE: 1/4" = 1'-0"A2

LIGHT POLE FOUNDATION DETAIL

0 2' 4' 8'

SCALE: 1/2" = 1'-0"B4

SCREEN WALL SECTION

0 1' 2' 4'SCALE: 3/4" = 1'-0"B2

FIRE SUPPRESSION PUMP

0 1' 2' 3'

A

M E

N D

/1

/2

U

P D

A T

E D

F D

FINISH REMARKS:

1.

2.

PAINT HANGAR BAY STEEL STRUCTURE ACCORDING

TO SPECIFICATION 09 97 13.27 EXTERIOR COATING

OF STEEL STRUCTURES.

BID OPTION: 5 COAT FUEL RESISTIVE RESINOUS

FLOORING (EF-2).

H U

R L

B U

R T

F

IE

L D

F

L O

R

ID

A H

A N

G A

R

A M

U P

R O

J E

C T

N O

F

T E

V

M O

B

IL

E D

IS

T

R

IC

T M

O B

IL

E

A

L A

B A

M A

Mobile District

US Army Corps of

Engineers ®

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R N

O

U S

A R

M Y

C O

R P

S

G

IN

E E

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

FILE:

DATE:

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y

M O

B U

R N

S

M c D

O N

N E

L L

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S B

M T

B Y

P L

O T

S C

A L E

S

IZ

E x

F

IL

E N

A M

E

C K

D B

Y

P L

O T

D A

T E

D A

T E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

P R

O J E

C T

N U

M B

E R

C A

D D

C O

D E

J U

L Y

W

-2

-R

-0

F T

E V

M E

F

JU

L

Y

A

M A

S H

E K

AMENDMENT NO. 0004

12/11/2020 5:16:40 PM

/8

'-0

E . A

L L

E N

E . A

L L

E N

A

C O

H E

N

A-701-0004

A -7

-0

A-701

R O

O M

F

IN

IS

H

S C

H E

D U

L E

ROOM FINISH SCHEDULE

ROOM

NUMBER ROOM NAME FLOOR

BASE WALLS

CEILING REMARKSMATERIAL NORTH EAST SOUTH WEST

224 ENGINES, ELECTRIC, & HYDRO NCOIC RF-2 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

225 SECURE CLASSIFIED STORAGE VAULT RF-2 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

226 COMNAV, INTEGRATED, AVIONICS, &

ELECTRONIC WAREFARE NCOIC

RF-2 RB-1 DP-1 DP-1 PA-2 PA-2 ACT-1

227 ASSISTANT SECTION CHIEFS RF-2 RB-1 PA-2 DP-1 DP-1 PA-2/DP-1 ACT-1

228 SENIOR SUPERINTENDENT RF-2 RB-1 DP-1 DP-1 DP-1 PA-2 ACT-1

230 WEAPONS TEAM ROOM RF-1,2 RB-1 PA-2 PA-2 DP-1 - ACT-1

230A WEAPONS PRODUCTION ROOM RF-1,2 RB-1 PA-2 - DP-1 PA-2 ACT-1

231 SENIOR SUPERINTENDENT RF-2 RB-1 DP-1 DP-1 PA-2 PA-2 ACT-1

232 NCOIC & ASST NCOIC RF-2 RB-1 DP-1 DP-1 PA-2 DP-1 ACT-1

233 SEC CHIEF & ASST SEC CHIEF RF-2 RB-1 DP-1 PA-2 PA-2 DP-1 ACT-1

234 WOMENS TOILET TLP-1 TLP-1 /

TLC-1,2

TLC-2/PA-1/SSF-

TLC-1,2/PA-1 TLC-2/PA-1 TLC-2/PA-1/SSF-

PA-8

235 JAN RF-2 RB-1 PE-1 FRP-1 FRP-1 FRP-1 PE-1

236 MENS TOILET TLP-1 TLP-1 /

TLC-1,2

TLC-1,2/PA-1/SS

F-3

TLC-2/PA-1/SS

F-3

TLC-1,2/PA-1/SS

F-3

TLC-1,2/PA-1 PE-1

237 MECH CH-1 - PA-1 PA-1 PA-1 PA-1 PA-8

238 VEST WOM-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-8

240 CORRIDOR RF-2 RB-1 RE: ELEV. RE: ELEV. RE: ELEV. RE: ELEV. ACT-1

241 VEST RF-2 RB-1 PA-2,7 PA-2 PA-2 PA-2 ACT-1

301 CTK CH-1/RF-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-8

301A OFFICE SUPPLY & MISC STORAGE CH-1/RF-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-8

301B TOOL INSPECTION REPAIR AREA CH-1/RF-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-8

301C EXPENDABLES SPARE/BROKEN TOOL AREA CH-1/RF-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-8

301D EQUIPMENT MANAGER / SUPPORT / TODO CH-1/RF-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-8

301E ENGINE STORAGE CH-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-8

302 SUPPORT NCOIC RF-1 RB-1 PA-2 PA-2 PA-2/DP-1 PA-2/DP-1 ACT-1

303 PRIVATE SUPPORT NCOIC RF-1 RB-1 DP-1 DP-1 PA-2 PA-2 ACT-1

304 LASER ETCHER ROOM CH-1 - PA-1 PA-1 PA-1 PA-1 PA-8

305 DASH21 EQUIPMENT STORAGE CH-1 - PA-1 PA-1 PA-1 PA-1 PA-8

306 WOMENS TOILET TLP-1 TLP-1 /

TLC-1,2

TLC-2/PA-1 TLC-2/PA-1 TLC-2/PA-1 TLC-2/PA-1 PE-1

307 MENS TOILET TLP-1 TLP-1 /

TLC-1,2

TLC-2/PA-1 TLC-2/PA-1 TLC-2/PA-1 TLC-2/PA-1 PE-1

308 COMM CH-1 - PA-1 PA-1 PA-1 PA-1 PA-8

310 JAN RF-2 RB-1 TLC-2 PE-1 PE-1 TLC-2 PE-1

311 FIRE PUMP / FOAM ROOM CH-1 - PA-1 PA-1 PA-1 PA-1 PA-8

312 ELEC CH-1 - PA-1 PA-1 PA-1 PA-1 PA-8

313 MECH CH-1 - PA-1 PA-1 PA-1 PA-1 PA-8

314 VEST WOM-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-8

315 CORRIDOR RF-1 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

316 VEST RF-1 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

317 CORRIDOR RF-1 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

401 OPEN-FLOOR GUN MAINTENANCE CH-1 - PA-1 PA-1 PA-1 PA-1 PA-8

401A ARMAMENT EQUIPMENT STORAGE CH-1 - PA-1 PA-1 PA-1 PA-1 PA-8

402 CRANE SECURE WEAPONS STORAGE CH-1 - PA-1 PA-1 PA-1 PA-1 PA-8

403 SNC BAY CH-1 - PA-1 PA-1 PA-1 PA-1 PA-8

404 SNC EXTERIOR COVERED STORAGE - - - - - - -

405 SNC EXTERIOR COVERED STORAGE - - - - - - -

501 HANGAR BAY EF-1 - PA-1 PA-1 PA-1 PA-1 PA-8 1, 2

502 CREW CHIEFS TEAM ROOM RF-1,2 RB-1 PA-2 PA-2/DP-1 PA-2 PA-2 ACT-1

503 SENIOR SUPERINTENDENT RF-2 RB-1 DP-1 PA-2 PA-2 PA-2/DP-1 ACT-1

504 ASST SEC CHIEF RF-2 RB-1 DP-1 PA-2 DP-1 DP-1 ACT-1

505 ASST SEC CHIEF AND NCOIC RF-2 RB-1 PA-2 PA-2 DP-1 DP-1 ACT-1

506 PRODUCTION TEAM ROOM RF-1,2 RB-1 PA-2/DP-1 PA-2/DP-1 PA-2 PA-2/DP-1 ACT-1

506A PRODUCTION SUPERINTENDENT RF-1,2 RB-1 PA-2 DP-1 PA-2 DP-1 ACT-1

507 SPO RF-2 RB-1 DP-1 PA-2/DP-1 PA-2 PA-2 ACT-1

508 AFETS RF-2 RB-1 PA-2 DP-1 DP-1 PA-2 ACT-1

510 LEAD PRODUCTION SUPERINTENDENT RF-2 RB-1 PA-2 DP-1 DP-1 DP-1 ACT-1

511 FSR RF-2 RB-1 PA-2 DP-1 DP-1 DP-1 ACT-1

512 PLANNING AND SCHEDULING RF-2 RB-1 DP-1 DP-1 PA-2 PA-2/DP-1 ACT-1

513 DEBRIEF / JOB CONTROL RF-1 RB-1 PA-2 PA-2 PA-2 DP-1 ACT-1

514 CORRIDOR RF-2 RB-1 RE: ELEV. RE: ELEV. RE: ELEV. RE: ELEV. ACT-1

515 COVERED TUG DOOR - - - - - - -

516 CORRIDOR EF-1 - PA-1 PA-1 PA-1 PA-1 PA-8 1, 2

601 SUPPLY ROOM RF-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-8

602 HAZARDOUS STORAGE CH-1 - PA-1 PA-1 PA-1 PA-1 PA-8

603 COVERED LAUNCH PIT - - - - - - -

604 EXTERIOR COVERED STORAGE - - - - - - -

605 CORRIDOR RF-1 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

606 CORRIDOR EF-1 - PA-1 PA-1 PA-1 PA-1 PA-8 1, 2

ROOM FINISH SCHEDULE

ROOM

NUMBER ROOM NAME FLOOR

BASE WALLS

CEILING REMARKSMATERIAL NORTH EAST SOUTH WEST

GROUND FLOOR

101 SNC SUPPORT RF-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-8

102 BREAK RF-1,2 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

103 SNC LOGISTICS SUPPORT RF-1 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

103A LOGISTICS OFFICE RF-1 RB-1 PA-2 PA-2 PA-2 PA-2 ACT-1

104 SNC LOGISTICS MANAGER RF-1 RB-1 PA-2 PA-2 PA-2 PA-2 ACT-1

105 SNC CLS READY ROOM RF-1,2 RB-1 PA-2/DP-1 PA-2/DP-1 PA-2/DP-1 PA-2 ACT-1

106 SNC FIELD MANAGER RF-1 RB-1 PA-2 DP-1 DP-1 PA-2 ACT-1

107 SNC FIELD MANAGER RF-1 RB-1 PA-2 PA-2 DP-1 DP-1 ACT-1

108 SNC FIELD MANAGER RF-1 RB-1 DP-1 PA-2 DP-1 DP-1 ACT-1

109 SNC AIRCRAFT MAINTENANCE MANAGER RF-1 RB-1 DP-1 PA-2 DP-1 DP-1 ACT-1

110 SNC QUALITY ASSURANCE RF-1 RB-1 DP-1 PA-2 DP-1 DP-1 ACT-1

111 SNC STORAGE RF-1 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

112 MENS TOILET TLP-1 TLP-1 /

TLC-1,2

TLC-2/PA-1 TLC-2/PA-1 TLC-2/PA-1 TLC-1,2/PA-1 PA-8

113 WOMENS TOILET TLP-1 TLP-1 /

TLC-1,2

TLC-2/PA-1 TLC-1,2/PA-1 TLC-2/PA-1 TLC-2/PA-1 PA-8

114 SHARED CONF CPT-1 RB-1 PA-2/FWP-1 PA-2 PA-2 PA-2 ACT-1

115 POTFF CPT-1 RB-1 PA-2 PA-2 PA-2 PA-2 ACT-1

116 LOGISTICS WAREHOUSE CH-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-1

117 ARMAMENT SUPPORT SECTION CH-1 - PA-1 PA-1 PA-1 PA-1 PA-8

118 SUPPORT SECTION NCOIC RF-1 RB-1 PA-2 PA-2 PA-2 PA-2 ACT-1

120 COMMON OFFICE / READY ROOM / CRANE

OPEN OFFICE

RF-1,2 RB-1 PA-2 PA-2 PA-2/DP-1 PA-2 ACT-1

121 ARMAMENT NCOIC RF-2 RB-1 DP-1 PA-2 PA-2 DP-1 ACT-1

122 CRANE FIELD SERVICE LEAD RF-2 RB-1 DP-1 DP-1 PA-2 DP-1 ACT-1

123 ARMAMENT FLIGHT CHIEF RF-2 RB-1 DP-1 DP-1 PA-2 PA-2 ACT-1

124 STORAGE CH-1 - PA-1 PA-1 PA-1 PA-1 PA-8

125 ELEC CH-1 - PA-1 PA-1 PA-1 PA-1 PA-8

126 COMM CH-1 - PA-1 PA-1 PA-1 PA-1 PA-8

127 VEST WOM-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-8

128 CORRIDOR RF-2 RB-1 RE: ELEV. RE: ELEV. RE: ELEV. RE: ELEV. ACT-1

129 VEST WOM-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-8

130 FIRE PROTECTION ROOM CH-1 - PA-1 PA-1 PA-1 PA-1 PA-8

131 STORAGE CH-1 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

201 CCS COMMANDER SUPPORT SECTION CPT-1 RB-1 PA-2 PA-2 PA-2 PA-1 ACT-1

202 COMMANDER SUITE CPT-2 RB-1 DP-1 PA-2 DP-1 DP-1 ACT-1

202A RECEPTION CPT-2 RB-1 PA-2 DP-1 DP-1 DP-1 ACT-1

203 COMMANDER OFFICE CPT-2 RB-1 PA-2 DP-1 DP-1 PA-2 ACT-1

204 CONF CPT-2 RB-1 DP-1 DP-1 PA-2 PA-2 ACT-1

205 SECTION COMMANDER CPT-2 RB-1 DP-1 DP-1 PA-2 DP-1 ACT-1

206 MAINTENANCE OFFICER CPT-2 RB-1 DP-1 DP-1 PA-2 DP-1 ACT-1

207 SUPERINTENDENT (CHIEF MASTER

SERGEANT)

CPT-2 RB-1 PA-2/DP-1 PA-2 PA-2 DP-1 ACT-1

208 FIRST SERGEANT CPT-2 RB-1 PA-2 PA-2 PA-2/DP-1 DP-1 ACT-1

210 FIRST SERGEANT CPT-2 RB-1 PA-2 DP-1 DP-1 DP-1 ACT-1

211 AMU CONF CPT-1 RB-1 PA-1 PA-1 PA-1 PA-2 ACT-1

212 OIC CPT-1 RB-1 PA-2 PA-2 PA-2 PA-2 ACT-1

212A AMU SUPERINTENDENT CPT-1 RB-1 PA-2 PA-2 PA-2 PA-2 ACT-1

213 ASST OIC CPT-1 RB-1 PA-2 PA-2 PA-2 PA-2 ACT-1

213A ASST AMU SUPERINTENDENT CPT-1 RB-1 PA-2 PA-2 PA-2 PA-2 ACT-1

214 COPY RF-2 RB-1 PA-2 PA-2 PA-2 PA-5 ACT-1

215 NURSING CPT-1 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

216 AUDITORIUM RF-1 RB-1 PA-2 PA-2 PA-2 PA-4 ACT-1

217 MULTI-PURPOSE RF-1,2 RB-1 PA-1 PA-1 PA-1,4 PA-1 ACT-1/PA-8

217A RECYCLE RF-1,2 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

218 SECURE COMM CH-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-8

220 MOBILITY SECTION & TRAINING MANAGERS CPT-1 RB-1 PA-2 PA-2 PA-2 PA-2 ACT-1

221 MENS TOILET TLP-1 TLP-1 /

TLC-1,2

TLC-1,2/PA-1 TLC-2/PA-1 TLC-2/PA-1 TLC-2 PA-8

222 WOMENS TOILET TLP-1 TLP-1 /

TLC-1,2

TLC-1,2/PA-1 TLC-2/PA-1 TLC-1,2/PA-1 TLC-2 PA-8

223 SPECIALISTS TEAM ROOM RF-1,2 RB-1 PA-2 PA-2 PA-2 PA-2/DP-1 ACT-1

A

M E

N D

U

P D

A T

E D

P L

A N

A N

D S

C H

E D

U L

E

/1

/2

GENERAL ROOM FINISH SCHEDULE NOTES:

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

22.

23.

24.

REFER TO SPECIFICATION 09 06 00 SCHEDULE OF FINISHES FOR EXTERIOR AND INTERIOR

FINISH MATERIALS. BASIS OF DESIGN OR EQUIVALENT COLOR AND FINISH CODES ARE AS

INDICATED ON THE ROOM FINISH SCHEDULE.

REFER TO INTERIOR ELEVATIONS, REFLECTED CEILING DRAWINGS, FINISH

DRAWINGS ,ENLARGED PLAN DRAWINGS AND INTERIOR DETAIL DRAWINGS FOR ADDITIONAL

FINISH PLACEMENT INFORMATION.

REFER TO ELECTRICAL DRAWINGS, MECHANICAL DRAWINGS, STRUCTURAL DRAWINGS AND

COMMUNICATION DRAWINGS FOR COORDINATION OF BUILDING FINISHES TO BUILDING

SYSTEMS.

REFER TO FINISH DRAWINGS FOR PLACEMENT OF FLOOR FINISHES, FLOOR PATTERNS AND

FLOOR MATERIAL CHANGES. REFER TO FLOORING TRANSITION DETAILS FOR TRANSITIONS

BETWEEN ADJOINING FLOORING MATERIALS.

REFER TO FINISH DRAWINGS AND INTERIOR ELEVATIONS FOR WALL FINISH EXTENTS,

CORNER GUARD LOCATIONS, SIGNAGE, AND SPECIALTY WALL FINISH LOCATIONS.

REFER TO REFLECTED CEILING DRAWINGS FOR CEILING HEIGHTS AND CEILING MATERIAL

EXTENTS.

REFER TO ENLARGED TOILET DRAWINGS, WALL FINISH PLANS AND INTERIOR ELEVATIONS

FOR PLACEMENT OF INTERIOR FINISHES IN TOILET/LOCKER ROOMS.

REFER TO MILLWORK DETAIL DRAWINGS AND INTERIOR ELEVATIONS FOR ASSIGNMENT OF

SOLID SURFACE AND PLASTIC LAMINATE FINISHES AND ADDITIONAL INFORMATION.

PROVIDE BLOCKING AS REQUIRED TO SECURE ALL WALL MOUNTED ITEMS INCLUDING

TOILET FIXTURES, TOILET ACCESSORIES, TOILET PARTITIONS, MILLWORK, SHELVES,

COUNTERTOP SUPPORTS, MARKERBOARDS, TACKBOARDS, FLAT PANEL DISPLAYS,

CAMERAS, ACOUSTICAL WALL PANELS, AND ANY OTHER WALL MOUNTED OBJECT.

UNLESS NOTED OTHERWISE, ALL EXPOSED STRUCTURAL STEEL TO BE PAINTED PA-8. ALL

EXTERIOR STEEL TO BE PAINTED IN ACCORDANCE WITH SPECIFICATION 09 97 13.27

EXTERIOR COATING OF STEEL STRUCTURE.

ALL WINDOW STOOLS TO BE SSF-2.

ALL DOOR FRAMES AND HOLLOW METAL DOORS TO BE PA-3.

ALL METAL FABRICATIONS AND HANDRAILS TO BE PA-3.

INTERIOR CAULKING TO MATCH ADJACENT WALL FINISH COLOR.

NO FINISHES REQUIRED ON CONCRETE WALLS OR CONCRETE CEILINGS UNLESS NOTED

OTHERWISE.

ALL EXPOSED CONCRETE FLOORS SHALL BE SEALED.

WALL CORNER GUARDS TO BE INSTALLED STARTING AT THE TOP OF THE SCHEDULED WALL

BASE.

AT GYPSUM BOARD SOFFITS AND BULKHEADS, PAINT ALL EXPOSED SURFACES.

PAINT ALL EXPOSED STRUCTURAL STEEL ELEMENTS, MISCELLANEOUS STEEL, PIPING,

HANGERS, VALVES AND CONDUITS EXCEPT PRE-FINISHED LINER PANELS AND FOAM

GENERATORS. THE PAINT COLOR SHALL BE AS INDICATED ON SCHEDULE. ALL FIRE

PROTECTION PIPING COLOR SHALL BE SAFETY RED.

ALL EXPOSED MECHANICAL AND ELECTRICAL EQUIPMENT AND ASSOCIATED SUPPORTING

EQUIPMENT TO BE PAINTED PA-8 UNLESS OTHERWISE REQUIRED BY CODE. COORDINATE

WITH MECHANICAL / ELECTRICAL FOR FINISHES ON MECHANICAL OR ELECTRICAL

EQUIPMENT.

DO NOT PAINT PRE-FINISHED ITEMS, FINISHED METAL SURFACES, OPERATING PARTS,

LABELS OR WARNINGS.

REFER TO AND COORDINATE WITH FURNITURE DRAWINGS AND TYPICAL MOUNTING HEIGHTS

DRAWING FOR WALL MOUNTING HEIGHTS OF FF&E, VISUAL DISPLAYS AND AUDIO VISUAL

EQUIPMENT.

PROVIDE HORIZONTAL WINDOW BLINDS ON ALL EXTERIOR WINDOWS, W1.

RESILIENT TILE

5 COATS FLOOR

COATING SYSTEM

STAINLESS STEEL

EDGE STRIP

CONCRETE FLOOR SLAB

RE: SPECIFICATION

ABA COMPLIANT SLOPING

RESILIENT REDUCER

RESILIENT FLOORING

/4

M

A X

CONCRETERESINOUS FLOORING

CONCRETE FLOOR SLAB

RESINOUS FLOORING

(NOT TO EXCEED 1:20

SLOPE)

SAW-CUT KERF (DEPTH AND

WIDTH SUFFICIENT TO ALLOW

RESINOUS FLOORING TO

TAPER AT FULL SPECIFIED

THICKNESS OR GREATER)

FACE OF FLOOR SLAB

RESINOUS FLOORING SYSTEM

RE: ROOM FINISH SCHEDULE

COVED CORNER -

COVER MORTAL JOINT

CMU - RE: PLANS

MORTAR JOINT

CARPETINGPORCELAIN TILE

ABA COMPLIANT SLOPING

METAL EDGE TRIM

CONCRETE FLOOR SLAB

PORCELAIN TILE

CARPET

FEATHER TOPPING AT CARPET-

TO-TILE TRANSITION IF

REQUIRED TO ENSURE 1/4" MAX

TRANSITION

/4

M

A X

RESILIENT FLOORINGCARPETING

ABA COMPLIANT SLOPING

METAL EDGE TRIM

CONCRETE FLOOR SLAB

CARPETING

RESILIENT FLOORING

/4

M

A X

RESILIENT FLOORINGPORCELAIN TILE

ABA COMPLIANT SLOPING

METAL EDGE TRIM

CONCRETE FLOOR SLAB

PORCELAIN TILE

RESILIENT FLOORING

/4

M

A X

FACILITY/SPACE

TYPE

CONFERENCE ROOM

CLASSROOM

OPEN OFFICE

PRIVATE OFFICE

SPACE ACOUSTIC REQUIREMENTS

SOUND ISOLATION

PARTITIONS DOORS

BACKGROUND

NOISE LEVEL

REVERBERATION

TIME

NIC 45 OR GREATER

NIC 45

NIC N/A

NIC 30-45 NIC 20

NIC n/a

NIC 25

NIC 25 OR GREATER 30

35 N/A

< 1.0 SEC

< 0.6 SEC

< 0.8 SEC

1. CONFERENCE ROOMS, CLASSROOMS, OPEN OFFICE AND PRIVATE OFFICES

SHALL BE TESTED ACCORDING TO ASTM E336 AND MEET NOISE ISOLATION

CLASS (NIC) REQUIRMENTS AS STATED IN UFC 3-101-01 28 NOVEMBER 2011

CHANGE 4, 6 MARCH 2019.

NOISE ISOLATION CLASS (NIC) REQUIREMENTS:

H U

R L

B U

R T

F

IE

L D

F

L O

R

ID

A H

A N

G A

R

A M

U P

R O

J E

C T

N O

F

T E

V

M O

B

IL

E D

IS

T

R

IC

T M

O B

IL

E

A

L A

B A

M A

Mobile District

US Army Corps of

Engineers ®

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R N

O

U S

A R

M Y

C O

R P

S

G

IN

E E

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

FILE:

DATE:

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y

M O

B U

R N

S

M c D

O N

N E

L L

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S B

M T

B Y

P L

O T

S C

A L E

S

IZ

E x

F

IL

E N

A M

E

C K

D B

Y

P L

O T

D A

T E

D A

T E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

P R

O J E

C T

N U

M B

E R

C A

D D

C O

D E

J U

L Y

W

-2

-R

-0

F T

E V

M E

F

JU

L

Y

A

M A

S H

E K

AMENDMENT NO. 0004

12/11/2020 5:11:11 PM

A s in d ic a te d

E . A

L L

E N

E . A

L L

E N

A

C O

H E

N

A-702-0004

A -7

-0

A-702

R O

O M

F

IN

IS

H

L E

G E

N D

G

E N

E R

A L

N O

T E

S

FINISH LEGEND - BASIS OF DESIGN OR EQUIVALENT

MATERIAL MANUF. PRODUCT NUMBER COLOR DESCRIPTION REMARKS

ACOUSTICAL CEILING TILE

ACT-1 ARMSTRONG ULTIMA TEGULAR #1942 WHITE 24" x 24" - ACOUSTICAL CEILING TILE

CONCRETE

CH-1 - - - HARDENED/SEALER RE: 03 30 00. 00 10

CORNER GUARD

CG-1 - - - STAINLESS STEEL SURFACE

MOUNTED

FLOORING

CPT-1 INTERFACE DETOURS AHEAD # 1472302500 105159 ONYX/ TONAL CARPET TILE

CPT-2 INTERFACE AE 3111 #138830AK00 104674 SMOKE CARPET TILE

EF-1 - - LIGHT GRAY WITH SHARKGRIP FUEL RESISTIVE RESINOUS

FLOORING - 3 COAT SYSTEM

EF-2 - - LIGHT GRAY WITH SHARKGRIP FUEL RESISTIVE RESINOUS

FLOORING - 5 COAT SYSTEM

RF-1 JOHNSONITE MINERALITY RUBBER TILE MRLR-XX PA9 BECKA RUBBER TILE

RF-2 JOHNSONITE MINERALITY RUBBER TILE MRLR-XX PA7 DOLO RUBBER TILE

WOM-1 CONSTRUCTION

SPECIALITIES

PEDITRED G4 7325 WROUGHT IRON WALK-OFF MAT

GROUT

GR-1 TEC SPECIALTY POWER GROUT 939 MIST LATEX GROUT

PAINT

PA-1 SHERWIN WILLIAMS SW7070 SITE WHITE LATEX

PA-2 SHERWIN WILLIAMS SW7066 GRAY MATTERS LATEX

PA-3 SHERWIN WILLIAMS SW7075 WEB GRAY LATEX

PA-4 SHERWIN WILLIAMS SW6531 INDIGO LATEX

PA-5 SHERWIN WILLIAMS SW6747 ARGYLE LATEX

PA-6 SHERWIN WILLIAMS SW6682 JUNE DAY LATEX

PA-7 SHERWIN WILLIAMS SW6258 TRICORN BLACK LATEX

PA-8 SHERWIN WILLIAMS SW7007 CEILING BRIGHT WHITE LATEX

PE-1 SHERWIN WILLIAMS SW7007 CEILING BRIGHT WHITE EPOXY

PLASTIC LAMINATE

PLAM-1 WILSONART 4882-38 OILED SOAPSTONE CASEWORK

PLAM-2 NEVAMAR MXT003-T SILVER ALU METALX CASEWORK

RESILIENT BASE

RB-1 JOHNSONITE TRADITIONAL WALL BASE 71 STORM CLOUD CG

SOLID SURFACE FABRICATION

SSF-1 CORIAN SILVER BIRCH COUNTERTOPS

SSF-2 WILSONART 9115GS ZEN GREY COUNTERTOPS AND WINDOWSILLS

SSF-3 INPRO CORP. BIOPRISM SOLID SURFACE GLACIER P9055 SHOWER WALL PANELS

TILE

TLC-1 CROSSVILLE COLOR BY NUMBERS A PERFECT TEN - MATTE CERAMIC 4X8

TLC-2 CROSSVILLE COLOR BY NUMBERS SIXTH SENSE - MATTE CERAMIC 4X8

TLP-1 MARAZZI SISTEM P PROJECT GRIGIO SCURA, UNPOLISHED PORCELAIN 12X24

WALLS

DP-1 - - - DEMOUNTABLE PARTITION

FRP-1 CRANE COMPOSITES GLASBORD 636 SMOOTH GRAY FIBERGLASS REINFORCED PANEL

FWP-1 KNOLL TEXTILES ELEMENT W1077/12 COBALT FABRIC WRAPPED ACOUSTICAL

PANEL

MWP-1 - - WHITE PREFINISHED METAL WALL PANEL

WM-1 - - - WIRE MESH PARTITION

NTSSCALE:A1

FLOOR TRANSITION

NTSSCALE:A2

FLOOR TRANSITION

NTSSCALE:A3

FLOORING DETAIL

NTSSCALE:B1

FLOOR TRANSITION

NTSSCALE:B2

FLOOR TRANSITION

NTSSCALE:B3

FLOOR TRANSITION

A

M E

N D

U

P D

A T

E D

P L

A N

A N

D S

C H

E D

U L

E

/1

K

L

M

N

P

8 9 10 11 12 13 14

A-751

A3

A-751C3

A-751

D4

A-751 B4

HANGAR BAY

SPECIALISTS TEAM

ROOM

ASSISTANT SECTION

CHIEFS

COMNAV,

INTEGRATED,

AVIONICS, &

ELECTRONIC

WAREFARE NCOIC

ENGINES, ELECTRIC,

& HYDRO NCOIC

SECURE CLASSIFIED

STORAGE VAULT

MOBILITY SECTION &

TRAINING

MANAGERS

WOMENS TOILET

MENS TOILET

AUDITORIUM

RECYCLE

217A

SECURE COMM

MULTI-PURPOSE

WEAPONS TEAM

ROOM

WEAPONS

PRODUCTION ROOM

230A

SENIOR

SUPERINTENDENT

NCOIC & ASST NCOIC

SEC CHIEF & ASST

SEC CHIEF

MENS TOILET

JAN

WOMENS TOILET

MECH

COMMANDER OFFICE

RECEPTION

202A

CONF

SECTION

COMMANDER

MAINTENANCE

OFFICER

SUPERINTENDENT

(CHIEF MASTER

SERGEANT)

FIRST SERGEANT

FIRST SERGEANT

COMMANDER SUITE

CCS COMMANDER

SUPPORT SECTION

COPY

NURSING

ASST AMU

SUPERINTENDENT

213A

ASST OIC

OIC

AMU

SUPERINTENDENT

212A

AMU CONF

CORRIDOR

VEST

VEST

CRANE SECURE

WEAPONS STORAGE

SUPPORT SECTION

NCOIC

CREW CHIEFS TEAM

ROOM

SENIOR

SUPERINTENDENT

CORRIDOR

A-422

D1

B1

C1

A1

TLC-1

TLC-1

TLC-1

TLC-1

TLC-1

TLC-1

12' - 0" 4' - 0"

3' - 8 3/8" 4' - 0"

24' - 0" 3' - 7"

TLC-2/

PA-1

TLC-2/PA-1

SSF-3

SSF-3 TLC-2/PA-1

TLC-2/

PA-1

TLC-2/

PA-1

PA-2,7

RE: TYP. DETAIL A-712

PA-2,7

RE: TYP. DETAIL A-712

P A

-2 ,4

R E

T

Y P

D

E T

A

IL

A -7

P A

-2 ,7

P A

-2 ,4

R E

T

Y P

D

E T

A

IL

A -7

PA-2,5

RE: TYP. DETAIL A-712

PA-2,5

RE: TYP. DETAIL A-712

PA-2,5

RE: TYP. DETAIL A-712

P A

-2 ,6

R E

T

Y P

D

E T

A

IL

A -7

-2 ,6

R E

T

Y P

D

E T

A

IL

A -7

-4

PA-2,5

PA-5

PA-5

PA-5

P A

-4

A1

A-702

CORRIDOR

12' - 0"

CG-1

CG-1CG-1

CG-1

CG-1

CG-1

CG-1CG-1

CG-1

CG-1

A-402

C4

A-402C3

A4

GENERAL FLOOR FINISH PLAN NOTES:

1. REFER TO A-711 FOR NOTES.

RF-1, RUBBER TILE

RF-2, RUBBER TILE

WOM-1, WALK-OFF MAT

TLP-1, PORCELAIN TILE

FINISH & SIGNAGE PLAN LEGEND

3" 1' - 0" 3"

**TYPICAL PAINT CONDITION AT DOOR

ALCOVES

** TYPICAL PAINT CONDITION AT

DOORS FLUSH IN WALL

INTERIOR ROOM

SIGNAGE, RE: MOUNTING

DETAIL A-742, TYP.

REFERENCE FINISH PLANS AND

ELEVATIONS FOR ACCENT COLOR CODE

N

H U

R L

B U

R T

F

IE

L D

F

L O

R

ID

A H

A N

G A

R

A M

U

P R

O J E

C T

N O

F

T E

V

M O

B

IL

E D

IS

T

R

IC

T

M O

B

IL

E A

L A

B A

M A

Mobile District

US Army Corps of

Engineers ®

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R N

O

U S

A R

M Y

C O

R P

S

G

IN

E E

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

FILE:

DATE:

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y

M O

B U

R N

S

M c D

O N

N E

L L

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S B

M T

B Y

P L

O T

S C

A L E

S

IZ

E x

F

IL

E N

A M

E

C K

D B

Y

P L

O T

D A

T E

D A

T E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

P R

O J E

C T

N U

M B

E R

C A

D D

C O

D E

J U

L Y

W

-2

-R

-0

F T

E V

M E

F

JU

L

Y

A B C

D E F

KEY PLAN

NOT TO SCALE

A

M A

S H

E K

AMENDMENT NO. 0004

12/11/2020 5:11:47 PM

A s in d ic a te d

E A

L L

E N

E A

L L

E N

A

C O

H E

N

A-712-0004

A -7

-0

A-712

F

IN

IS

H

P L A

N A

R E

A

B

SCALE: 1/8" = 1'-0"A1

FINISH PLAN AREA - B

0 4' 8' 16'

N

SCALE: 1/4" = 1'-0"B4

TYP. ACCENT STRIPE DETAIL

0 2' 4' 8'

A

M E

N D

U

P D

A T

E D

P L

A N

A N

D S

C H

E D

U L

E

/1

J

D

5 6 7 8

OPEN-FLOOR GUN

MAINTENANCE

ARMAMENT

EQUIPMENT

STORAGE

401A

ARMAMENT

SUPPORT SECTION

SNC BAY

LOGISTICS

WAREHOUSE

SNC CLS READY

ROOM

SNC AIRCRAFT

MAINTENANCE

MANAGER

SNC FIELD MANAGER

SNC FIELD MANAGER

SNC FIELD MANAGER

SNC QUALITY

ASSURANCE

SNC STORAGE

SNC LOGISTICS

SUPPORT

SNC LOGISTICS

MANAGER

CORRIDOR

SNC EXTERIOR

COVERED STORAGE

C

4' - 0" 32' - 0"

PA-2,7

RE: TYP. DETAIL A-712

P A

-2 ,7

PA-7

G

H

GENERAL FLOOR FINISH PLAN NOTES:

1. REFER TO A-711 FOR NOTES.

RF-1, RUBBER TILE

RF-2, RUBBER TILE

WOM-1, WALK-OFF MAT

TLP-1, PORCELAIN TILE

FINISH & SIGNAGE PLAN LEGEND

N

H U

R L

B U

R T

F

IE

L D

F

L O

R

ID

A H

A N

G A

R

A M

U

P R

O J E

C T

N O

F

T E

V

M O

B

IL

E D

IS

T

R

IC

T

M O

B

IL

E A

L A

B A

M A

Mobile District

US Army Corps of

Engineers ®

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R N

O

U S

A R

M Y

C O

R P

S

G

IN

E E

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

FILE:

DATE:

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y

M O

B U

R N

S

M c D

O N

N E

L L

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S B

M T

B Y

P L

O T

S C

A L E

S

IZ

E x

F

IL

E N

A M

E

C K

D B

Y

P L

O T

D A

T E

D A

T E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

P R

O J E

C T

N U

M B

E R

C A

D D

C O

D E

J U

L Y

W

-2

-R

-0

F T

E V

M E

F

JU

L

Y

A B C

D E F

KEY PLAN

NOT TO SCALE

A

M A

S H

E K

AMENDMENT NO. 0004

12/11/2020 5:12:24 PM

/8

'-0

E A

L L

E N

E A

L L

E N

A

C O

H E

N

A-714-0004

A -7

-0

A-714

F

IN

IS

H

P L

A N

A R

E A

D

SCALE: 1/8" = 1'-0"A1

FINISH PLAN AREA - D

0 4' 8' 16'

N

A

M E

N D

U

P D

A T

E D

P L

A N

A N

D S

C H

E D

U L

E

/1

GENERAL SIGNAGE SCHEDULE NOTES:

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

REFER TO SIGNAGE PLACEMENT DRAWINGS FOR LOCATION

OF INTERIOR SIGNS.

REFER TO EXTERIOR BUILDING ELEVATIONS, SIGNAGE

SCHEDULE AND SIGNAGE DRAWINGS FOR LOCATION OF ALL

EXTERIOR SIGNAGE.

REFER TO SIGNAGE DETAILS FOR SIGNAGE CONSTRUCTION

AND MOUNTING ELEVATION.

REFER TO ARCHITECTURAL DRAWINGS FOR COORDINATION

OF SIGNAGE INSTALLATION TO WALL CONSTRUCTION.

SIGNAGE MUST BE ANCHORED THRU THE SURFACE APPLIED

WALL FINISHES TO THE SUBSTRATE WALL.

ALL HARDWARE/MOUNTING ATTACHMENTS TO BE CONCEALED

AND APPROPRIATE FOR THE RECEIVING BUILDING SURFACE.

ALL SIGNAGE SHALL COMPLY WITH THE MOST CURRENT

VERSION OF THE ARCHITECTURAL BARRIERS ACT (ABA).

ALL SIGNAGE MOUNTED ON GLASS SHALL HAVE A MATCHING

BACK PLATE TO CONCEAL ATTACHMENT METHOD OF SIGN.

CONSTRUCT EXTERIOR GRADE SIGNAGE WITH MATERIAL

APPROPRIATE FOR EXTERIOR USAGE.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR

COORDINATING WITH SIGNAGE MANUFACTURER(S) TO

PROVIDE ANY ADDITIONAL SIGNAGE AS REQUIRED BY

GOVERNING MUNICIPALITY AT THE SITE LOCATION.

REFER TO INTERIOR ELEVATIONS, MURAL IMAGES, AND

SPECIFICATION SECTION 12 10 00 ENVIRONMENTAL GRAPHIC

ART MURAL SYSTEM FOR ADDITIONAL INFORMATION. MURAL

IMAGES ARE PLACE HOLDERS ONLY. FINAL ARTWORK FOR

MURAL IMAGES TO BE PROVIDED BY END USER PRIOR TO

SHOP DRAWING DOCUMENTATION.

ALL MESSAGE TEXT AS SHOWN ON THE SIGN SCHEDULE IS A

PLACE HOLDER ONLY AND IS NOT THE FINAL TEXT MESSAGE.

ALL MESSAGE TEXT SHALL BE CONFIRMED BY GOVERNMENT

END USER PRIOR TO SIGNAGE SHOP DRAWINGS. ALLOW FOR

MAXIMUM 4 DIGIT ROOM NUMBERS AND MINIMUM 25

CHARACTER ROOM NAMES TYPICAL FOR ALL SIGNS.

PROVIDE EXTERIOR BUILDING NUMBER SIGN PER BASE

STANDARDS AND IN ACCORDANCE WITH SIGN STANDARDS

UFC 3-120-1.

REFER TO 09 06 00 SCHEDULE OF FINISHES FOR BASIS OF DESIGN

OR EQUIVALENT MANUFACTURER, PRODUCT STYLE,

MATERIALS AND COLOR.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR

OBTAINING LOGO IMAGES FROM APPROVED GOVERNMENT

REPRESENTATIVE AND PROVIDING TO SIGNAGE

MANUFACTURER(S). SIGNAGE MANUFACTURER(S) SHALL BE

RESPONSIBLE FOR CREATING VECTOR IMAGES FOR

INCORPORATION INTO SIGNAGE BACKGROUND INSERTS AND

LOGO MEDALLION SIGNAGE.

PROVIDE MESSAGE INSERTS FOR WINDOW SIGNS WHERE

INDICATED IN THE SIGNAGE DRAWINGS OR SPECIFICATIONS.

H U

R L

B U

R T

F

IE

L D

F

L O

R

ID

A H

A N

G A

R

A M

U P

R O

J E

C T

N O

F

T E

V

M O

B

IL

E D

IS

T

R

IC

T M

O B

IL

E

A

L A

B A

M A

Mobile District

US Army Corps of

Engineers ®

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R N

O

U S

A R

M Y

C O

R P

S

G

IN

E E

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

FILE:

DATE:

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y

M O

B U

R N

S

M c D

O N

N E

L L

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S B

M T

B Y

P L

O T

S C

A L E

S

IZ

E x

F

IL

E N

A M

E

C K

D B

Y

P L

O T

D A

T E

D A

T E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

P R

O J E

C T

N U

M B

E R

C A

D D

C O

D E

J U

L Y

W

-2

-R

-0

F T

E V

M E

F

JU

L

Y

A

M A

S H

E K

AMENDMENT NO. 0004

12/11/2020 5:13:03 PM

/8

'-0

E . A

L L

E N

E . A

L L

E N

A

C O

H E

N

A-741-0004

A -7

-0

A-741

S

IG

N A

G E

S C

H E

D U

L E

SIGN TAG

SIGN

TYPE

MESSAGE TEXT

REMARKSNUMBER WORDING

S210 A 123 ARMAMENT FLIGHT CHIEF

S211 A 117 ARMAMENT SUPPORT SECTION

S212 A 118 SUPPORT SECTION NCOIC

S213 A 103 SNC LOGISTICS SUPPORT

S214 A 116 LOGISTICS WAREHOUSE

S215 A 104 SNC LOGISTICS MANAGER

S216 A 105 SNC CLS READY ROOM

S217 A 103 SNC LOGISTICS SUPPORT

S218 A 105 SNC CLS READY ROOM

S219 A 111 SNC STORAGE

S220 B 403 SNC BAY

S221 A 110 SNC QUALITY ASSURANCE

S222 A 109 SNC AIRCRAFT MAINTENANCE MANAGER

S223 A 108 SNC FIELD MANAGER

S224 A 107 SNC FIELD MANAGER

S225 A 106 SNC FIELD MANAGER

S226 A 105 SNC CLS READY ROOM

S227 A 401 OPEN-FLOOR GUN MAINTENANCE

S228 A 117 ARMAMENT SUPPORT SECTION

S229 A 105 SNC CLS READY ROOM

S230 A 401 OPEN-FLOOR GUN MAINTENANCE

S231 A 402 CRANE SECURE WEAPONS STORAGE

S232 A 502 CREW CHIEFS TEAM ROOM

S233 A 503 SENIOR SUPERINTENDENT

S234 A 504 ASST SEC CHIEF

S235 A 505 ASSISTANT SEC CHIEF & NCOIC

S236 A 401 OPEN-FLOOR GUN MAINTENANCE

S237 A 506 PRODUCTION TEAM ROOM

S238 A 507 SPO

S239 A 508 AFETS

S240 A 510 LEAD PRODUCTION SUPERINTENDENT

S241 A 511 FSR

S242 A 512 PLANNING AND SCHEDULING

S243 A 506 PRODUCTION TEAM ROOM

S244 A 513 DEBRIEF / JOB CONTROL

S245 A 301 CTK

S246 B 501 HANGAR BAY

S247 B 501 HANGAR BAY

S248 A 301 CTK

S249 A 301 CTK

S250 A 601 SUPPLY ROOM

S251 A 601 SUPPLY ROOM

S252 A 601 SUPPLY ROOM

S253 G - "SEE DETAIL"

S254 G - "SEE DETAIL"

S255 H - "SEE DETAIL"

S256 EXT2 - "SEE DETAIL"

S257 EXT2 - "SEE DETAIL"

S258 EXT2 - "SEE DETAIL"

S259 EXT2 - "SEE DETAIL"

S260 EXT2 - "SEE DETAIL"

S261 EXT2 - "SEE DETAIL"

S262 E - EMERGENCY EXIT

S263 J - NO ENTRY

S264 J - NO ENTRY

S265 E - EMERGENCY EXIT

S266 K - CONTROLLED AREA - FIRE DEPARTMENT

ACCESS ONLY

S267 B 124 STORAGE

S268 B 241 VESTIBULE TO HANGAR BAY

S268 L - NOT AN EXIT

S269 L NOT AN EXIT

S270 B 501 TO HANGAR BAY

S271 A 301 CTK

SIGN TAG

SIGN

TYPE

MESSAGE TEXT

REMARKSNUMBER WORDING

S155 B 501 HANGAR BAY

S156 B 310 JANITOR

S157 B 305 DASH21 EQUIPMENT STORAGE

S158 B 602 HAZARDOUS STORAGE

S159 A 217 MULTI-PURPOSE ROOM

S160 B 218 SECURE COMMUNICATION ROOM

S161 A 220 MOBILITY SECTION & TRAINING

MANAGERS

S162 C - MEN A

S163 C - WOMEN A

S164 A 216 AUDITORIUM

S165 F - BUILDING DIRECTORY B

S167 A 201 CCS COMMANDER SUPPORT SECTION

S168 A 211 AMU CONFERENCE ROOM

S169 A 230 WEAPONS PRODUCTION ROOM

S170 A 212 OIC / AMU SUPERINTENDENT

S171 A 213 ASSISTANT OIC / AMU SUPERINTENDENT

S172 A 215 NURSING

S173 A 201 CCS COMMANDER SUPPORT SECTION

S174 A 202 COMMANDER SUITE

S175 A 203 COMMANDER OFFICE

S176 A 204 CONFERENCE ROOM

S177 A 205 SECTION COMMANDER

S178 A 206 MAINTENANCE OFFICER

S179 A 210 FIRST SERGEANT

S180 A 207 SUPERINTENDENT

S181 A 208 FIRST SERGEANT

S182 A 202 COMMANDER SUITE

S183 C - MEN A

S184 B 235 JANITOR

S185 C - WOMEN A

S186 A 502 CREW CHIEFS TEAM ROOM

S187 A 230 WEAPONS TEAM ROOM

S188 A 233 SEC CHIEF & ASSISTANT SEC CHIEF

S189 A 232 NCOIC & ASSISTANT NCOIC

S190 A 231 SENIOR SUPERINTENDENT

S191 A 223 SPECIALISTS TEAM ROOM

S192 A 502 CREW CHIEFS TEAM ROOM

S193 A 223 SPECIALISTS TEAM ROOM

S194 B 501 HANGAR BAY

S195 A 224 ENGINES, ELECTRIC, & HYDRO NCOIC

S196 A 225 SECURE CLASSIFIED STORAGE VAULT

S197 A 226 COMNAV, INTEGRATED AVIONICS, &

ELECTRONIC WAREFARE NCOIC

S198 A 227 ASSISTANT SECTION CHIEFS

S199 A 228 SENIOR SUPERINTENDENT

S200 A 102 BREAK ROOM

S201 C - MEN A

S202 A 101 SNC SUPPORT

S203 C - WOMEN A

S204 A 114 CONFERENCE ROOM

S205 A 114 CONFERENCE ROOM

S206 A 115 POTFF

S207 A 120 COMMON OFFICE / READY ROOM

S208 A 121 ARAMENT NCOIC

S209 A 122 CRANE FIELD SERVICE LEAD

SIGN TAG

SIGN

TYPE

MESSAGE TEXT

REMARKSNUMBER WORDING

S100 D - NO SMOKING WITHIN 50' OF BUILDING

S101 EXT4 - "SEE DETAIL"

S102 EXT1 - BUILDING NUMBER

S103 EXT4 - "SEE DETAIL"

S104 B 237 MECHANICAL ROOM

S105 B 126 COMMUNICATION ROOM

S106 D - NO SMOKING WITHIN 25' OF BUILDING

S107 EXT4 - "SEE DETAIL"

S108 B 125 ELECTRICAL ROOM

S109 E 120 EMERGENCY EXIT ONLY

S110 D - NO SMOKING WITHIN 50' OF BUILDING

S111 EXT4 - "SEE DETAIL"

S112 B 101 SNC SUPPORT

S113 B 116 LOGISTICS WAREHOUSE

S114 EXT1 - BUILDING NUMBER

S115 E - EXIT ONLY

S116 B 403 SNC BAY

S117 B 403 SNC BAY

S118 EXT1 - BUILDING NUMBER

S119 B 401 OPEN-FLOOR GUN MAINTENANCE

S120 B 514 ADMIN & SHOPS

S121 B 501 HANGAR BAY

S122 G - "SEE DETAIL"

S123 G - "SEE DETAIL"

S124 EXT1 - BULIDING NUMBER

S125 B 501 HANGAR BAY

S126 B 301 CTK

S127 B 601 SUPPLY ROOM

S128 EXT1 - BUILDING NUMBER

S129 B 601 SUPPLY ROOM

S130 B 602 HAZARDOUS STORAGE

S131 A DASH21 EQUIPMENT STORAGE

S132 EXT1 - BUILDING NUMBER

S133 B 305 DASH21 EQUIPMENT STORAGE

S134 B - EMERGENCY EXIT

S135 E - EMERGENCY EXIT

S136 EXT1 - BUILDING NUMBER

S137 B 313 MECHANICAL ROOM

S138 B 312 ELECTRICAL ROOM

S139 EXT4 - "SEE DETAIL"

S140 D - NO SMOKING WITHIN 50' OF BUILDING

S141 B 311 FIRE PUMP / FOAM ROOM

S142 B 501 HANGAR BAY

S143 E - EMERGENCY EXIT

S144 B 240 MULTI-PURPOSE / AUDITORIUM

S145 EXT1 - BUILDING NUMBER

S146 B 217 MULTI-PURPOSE ROOM

S147 B 216 AUDITORIUM

S148 A 304 LASER ETCHER ROOM

S149 A 302 SUPPORT NCOIC

S150 A 303 PRIVATE SUPPORT NCOIC

S151 C - MEN A

S152 C - WOMEN A

S153 A 301 CTK

S154 B 308 COMMUNICATION ROOM

A. PROVIDE PICTOGRAM PER SIGN REQUIREMENTS.

B. COORDINATE WITH APPROVED GOVERNMENT REPRESENTATIVE

THE ROOM NAMES TO BE LISTED ON DIRECTIONAL AND

DIRECTORY SIGN TYPE(S).

SIGNAGE REMARKS:

A

M E

N D

U

P D

A T

E D

P L

A N

A N

D S

C H

E D

U L

E

/1

GENERAL FURNITURE PLAN NOTES:

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

REFER TO ARCHITECTURAL FLOOR PLANS FOR BUILDING LAYOUT,

DIMENSIONS, AND COORDINATION TO BUILDING SYSTEMS AND

STRUCTURE.

REFER TO ELECTRICAL DRAWINGS FOR COORDINATION OF LIGHTING,

POWER, DATA, COMMUNICATIONS, AND LOCATIONS OF OTHER WALL AND

FLOOR MOUNTED ELECTRICAL DEVICES AND EQUIPMENT FOR

COORDINATION TO FURNITURE LAYOUTS. CONTRACTOR SHALL IDENTIFY

ANY CONFLICTS WITH FURNITURE LAYOUTS.

REFER TO MECHANICAL DRAWINGS FOR COORDINATION OF PLUMBING

AND HVAC SYSTEMS TO FURNITURE LAYOUTS. THERMOSTATS,

DIFFUSERS AND ACCESS PANELS SHALL NOT CONFLICT WITH FURNITURE

LAYOUTS. CONTRACTOR SHALL IDENTIFY ANY CONFLICTS WITH

FURNITURE LAYOUTS.

REFER TO FF&E PACKAGE FOR FURNITURE PROCUREMENT

INFORMATION AND BASIS OF DESIGN OR EQUIVALENT SPECIFICATIONS.

FIELD VERIFY ALL BUILDING CONDITIONS PRIOR TO INSTALLATION OF

FF&E.

FURNITURE INSTALLER/CONTRACTOR SHALL COORDINATE

POWER/COMM/DATA CONNECTIONS WITH ELECTRICAL CONTRACTOR

PRIOR TO INSTALLATION OF ELECTRIFIED FURNISHINGS.

PROVIDE BLOCKING AS REQUIRED FOR ALL WALL MOUNTED

MARKERBOARDS, TACKBOARDS, STORAGE UNITS OR AV EQUIPMENT

INCLUDING FLAT PANEL DISPLAYS OR PROJECTION SCREENS.

INSTALL MARKERBOARDS AND TACKBOARDS AT 3'-0" TO THE BOTTOM OF

THE UNIT UNLESS NOTED OTHERWISE.

INSTALL CLOCKS AT 8'-0" AFF TO CENTER OF CLOCK UNLESS OTHERWISE

NOTED.

ALL FLAT PANEL DISPLAYS TO BE INSTALLED WITH ADJUSTABLE WALL

MOUNT BRACKETS TO ALLOW FOR CONCEALMENT OF ALL CORDS AND

ELECTRICAL/COMMUNICATIONS OUTLETS BEHIND THEM. COORDINATE

FLAT PANEL DISPLAY PLACEMENTS WITH WALL BLOCKING AND

ELECTRICAL DRAWINGS.

SYSTEMS FURNISHINGS ACCESSORIES SHALL BE PROCURED AS A KIT OF

PARTS. REFER TO FF&E DOCUMENTS FOR DETAILS.

FURNITURE, FIXTURES AND EQUIPMENT (FF&E) DRAWINGS PROVIDED

FOR COORDINATION WITH BUILDING SYSTEMS ONLY.

FOR TIME ZONE CLOCK MOUNTING HEIGHTS, REFER TO THE FF&E

PACKAGE ACCESSORIES SECTION. CENTER CLOCKS HORIZONTALLY ON

WALLS UNLESS NOTED OTHERWISE.

INSTALL ARTWORK AT LOCATIONS DESIGNATED ON DRAWINGS AND IN

ROOMS SPECIFIED IN THE FF&E DOCUMENTS.

PERSONAL TRASH AND RECYCLING BASKETS NOT SHOWN ON DRAWINGS

TO BE PROVIDED AT EACH WORKSTATION AND PRIVATE OFFICE DESK.

REFER TO FF&E SPECIFICATION PACKAGE FOR QUANTITIES AND

ADDITIONAL LOCATIONS.

FURNITURE AND EQUIPMENT SHOWN DASHED AND HALFTONED SHALL BE

GOVERNMENT FURNISHED, GOVERNMENT INSTALLED (GFGI). GFGI ITEMS

ARE NOT INCLUDED IN THE FF&E PACKAGE AND ARE SHOWN FOR

COORDINATION PURPOSES ONLY. GFGI ITEMS MAY INCLUDE PRINTERS,

COPIERS, FAX MACHINES, SHREDDERS, DIGITAL SENDERS, VENDING

MACHINES AND OTHER ITEMS AS INDICATED.

FF&E CONTRACTOR TO FIELD VERIFY ALL MEASUREMENTS AND SITE

CONDITIONS TO ENSURE PROPER FIT OF ALL FF&E. FURNISHINGS SHALL

NOT OVERLAP OR OBSTRUCT DOOR FRAMES, WALL SWITCHES,

THERMOSTATS, OR OTHER WALL MOUNTED ITEMS. MODIFICATIONS TO

FURNISHINGS LAYOUTS REQUIRED TO MEET BUILDING CONDITIONS AT

THE TIME OF INSTALLATION SHALL BE THE RESPONSIBILITY OF THE FF&E

CONTRACTOR. ALL MODIFICATIONS MUST BE APPROVED IN WRITING BY A

GOVERNMENT APPROVED REPRESENTATIVE PRIOR TO INSTALLATION OF

THE FURNISHINGS.

H U

R L

B U

R T

F

IE

L D

F

L O

R

ID

A H

A N

G A

R

A M

U P

R O

J E

C T

N O

F

T E

V

M O

B

IL

E D

IS

T

R

IC

T M

O B

IL

E

A

L A

B A

M A

Mobile District

US Army Corps of

Engineers ®

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R N

O

U S

A R

M Y

C O

R P

S

G

IN

E E

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

FILE:

DATE:

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y

M O

B U

R N

S

M c D

O N

N E

L L

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S B

M T

B Y

P L

O T

S C

A L E

S

IZ

E x

F

IL

E N

A M

E

C K

D B

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .