RTA DRAWINGS VOL 2.pdf

PDF 30 MB Posted

Attached to
Aircraft Maintenance Unit (AMU) and Weapons Hangar, Hurlburt Field, FL
Solicitation number
W9127820R0104
Issued by

About this file

This document contains details of a federal solicitation for construction services. The solicitation seeks to construct a new 105,041 square foot maintenance hangar, aircraft maintenance unit with shops, and weapons shop at Hurlburt Field, Florida. The scope of work includes a reinforced concrete foundation and floor slab, steel structure, masonry walls, standing seam metal roof, HVAC, fire detection and protection, mass notification system, utilities, pavements, site improvements, communications, and all necessary support to create a complete and usable facility. Roadway and parking will include associated primary utilities and communications, as well as realignment of existing infrastructure as required. Airfield pavements are also needed to provide aircraft access to the hangar. Special site conditions require excavation, fill, stabilization and demolition of seven existing buildings. The solicitation was issued by the Department of the Army Corps of Engineers Engineering District Mobile.

View the file

Other files

File Type Posted
AM05 DRAWINGS.pdf PDF
AM05.pdf PDF
AM04.pdf PDF
AM04 DRAWINGS.pdf PDF
AM03.pdf PDF
Minutes-Pre-Bid site visit.pdf PDF
Minutes-Pre-Bid demo site visit.pdf PDF
AM03 DRAWINGS.pdf PDF
AM02.pdf PDF
APPENDIX F- As Builts of Demo Buildings- 1 of 3.zip ZIP file
APPENDIX F- As Builts of Demo Buildings- 2 of 3.zip ZIP file
APPENDIX F- As Builts of Demo Buildings- 3 of 3.zip ZIP file
AM01 Drawings.pdf PDF
AM01.pdf PDF
VOL3.PDF PDF
VOL2.PDF PDF
VOL4.PDF PDF
RTA DRAWINGS VOL 1.pdf PDF
VOL6.PDF PDF
VOL1.PDF PDF
VOL5.PDF PDF
EM 385-1-1.pdf PDF
RTA DRAWINGS VOL 3.pdf PDF
Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US Army Corps of Engineers

MOBILE DISTRICT

109 SAINT JOSEPH STREET

MOBILE AL 36602

FTEV153009 SOF AMU &

WEAPONS HANGAR FACILITY

HURLBURT FIELD, FLORIDA

OKALOOSA COUNTY

AUGUST 2020

MOBILE DISTRICT PROJECT CODE: MEF20004

SOLICITATION NUMBER: W9127820R0104

VOLUME 2 OF 3

H U

R L

B U

R T

F

IE

L D

F

L O

R

ID

A H

A N

G A

R

A M

U

P R

O J E

C T

N O

F

T E

V

M O

B

IL

E D

IS

T

R

IC

T

M O

B

IL

E A

L A

B A

M A

Mobile District

US Army Corps of

Engineers ®

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R N

O

U S

A R

M Y

C O

R P

S O

F

E N

G

IN

E E

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

FILE:

DATE:

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y

M O

B U

R N

S

M c D

O N

N E

L L

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S B

M T

B Y

P L

O T

S C

A L E

S

IZ

E x

F

IL

E N

A M

E

C K

D B

Y

P L

O T

D A

T E

D A

T E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

P R

O J E

C T

N U

M B

E R

C A

D D

C O

D E

J U

L Y

W

-2

-R

-0

F T

E V

M E

F

JU

L

Y

A

M A

S H

E K

11/2/2020 8:53:44 AM

A

S N

E T

H E

N

A

S N

E T

H E

N A

M

A S

H E

K

G-001-0004

G -0

-0

G-001

S H

E E

T I N

D E

X

HANGAR AMU - VOLUME 1 - CIVIL/INFRASTRUCTURE DRAWING LIST

NUMBER NAME

CU507 UTILITY DETAILS 7

CU508 UTILITY DETAILS 8

CU509 UTILITY DETAILS 9

CU510 FUEL SPILL CONTAINMENT TANK DETAILS

CU511 LIFT STATION DETAILS 1

CU512 LIFT STATION DETAILS 2

CU513 LIFT STATION DETAILS 3

CU514 LIFT STATION DETAILS 4

CU515 CATHODIC PROTECTION DETAILS - 1

CU516 CATHODIC PROTECTION DETAILS - 2

CU517 DOOR TRACK CLEANOUT DETAILS

HANGAR AMU - VOLUME 1 - CIVIL/INFRASTRUCTURE DRAWING LIST

NUMBER NAME

CP102 PAVEMENT JOINTING PLAN 2

CP103 BASE BID + BID OPTION GSE CONCRETE PAVEMENT JOINTING PLAN 3

CP104 PAVEMENT JOINTING PLAN 4

CP110 PAVEMENT JOINTING PLAN 10 - BASE BID + BID OPTION GSE CONCRETE AND AIRCRAFT

PARKING APRON

CP111 PAVEMENT JOINTING PLAN 11 - BASE BID + BID OPTION AIRCRAFT PARKING APRON

CP121 PAVEMENT ELEVATION PLAN 1

CP122 PAVEMENT ELEVATION PLAN 2

CP123 PAVEMENT ELEVATION PLAN 3 BASE BID + BID OPTION GSE CONCRETE

CP124 PAVEMENT ELEVATION PLAN 4

CP130 PAVEMENT ELEVATION PLAN 10 - BASE BID + BID OPTION AIRCRAFT PARKING APRON AND

GSE CONCRETE

CP131 PAVEMENT ELEVATION PLAN 11 - BASE BID + BID OPTION AIRCRAFT PARKING APRON

CG100 OVERALL GRADING PLAN

CG101 GRADING PLAN GRID 1

CG102 GRADING PLAN GRID 2

CG103 GRADING PLAN GRID 3

CG104 GRADING PLAN GRID 4

CG105 GRADING PLAN GRID 5

CG106 GRADING PLAN GRID 6

CG107 GRADING PLAN GRID 7

CG108 GRADING PLAN GRID 8

CG109 GRADING PLAN GRID 9

CG110 GRADING PLAN GRID 10

CG113 GRADING PLAN GRID 13

CG114 GRADING PLAN GRID 14

CG120 BUILDING 90731 GRADING PLAN

CG121 BUILDING 90825 GRADING PLAN

CG130 BASE BID + BID OPTION PARKING GRADING PLAN GRID 1

CG131 BASE BID + BID OPTION AIRCRAFT PARKING APRON GRADING

CG301 CONSTRUCTION BERM PLAN

CG302 OVEREXCAVATION PLAN AND SETTLEMENT PLATE PLAN

CG305 EMBANKMENT AND BERM SECTIONS

CG306 EMBANKMENT AND BERM SECTIONS

CG501 GRADING DETAILS 1

CG502 GRADING DETAILS 2

CU100 OVERALL UTILITY PLAN

CU101 UTILITY PLAN GRID 1

CU102 UTILITY PLAN GRID 2

CU103 UTILITY PLAN GRID 3

CU104 UTILITY PLAN GRID 4

CU105 UTILITY PLAN GRID 5

CU106 UTILITY PLAN GRID 6

CU107 UTILITY PLAN GRID 7

CU108 UTILITY PLAN GRID 8

CU109 UTILITY PLAN GRID 9

CU110 UTILITY PLAN GRID 10

CU111 UTILITY PLAN GRID 11

CU112 UTILITY PLAN GRID 12

CU113 UTILITY PLAN GRID 13

CU114 UTILITY PLAN GRID 14

CU201 STORM DRAIN PROFILES 1

CU202 STORM DRAIN PROFILES 2

CU203 STORM DRAIN PROFILES 3

CU204 STORM DRAIN PROFILES 4

CU205 STORM DRAIN PROFILES 5

CU206 STORM DRAIN PROFILES 6

CU207 STORM DRAIN PROFILES 7

CU208 STORM DRAIN PROFILES 8

CU209 STORM DRAIN PROFILES 9

CU210 SANITARY SEWER PROFILES 1

CU211 SANITARY SEWER PROFILES 2

CU212 INDUSTRIAL WASTE PROFILES

CU213 WATER PROFILES

CU214 WATER PROFILES

CU215 WATER PROFILES

CU216 WATER PROFILES

CU220 COMMUNICATION PROFILES

CU221 COMMUNICATION PROFILES

CU222 COMMUNICATION PROFILES

CU223 ELECTRICAL PROFILES 1

CU224 ELECTRICAL PROIFILES 2

CU501 UTILITY DETAILS 1

CU502 UTILITY DETAILS 2

CU503 UTILITY DETAILS 3

CU504 UTILITY DETAILS 4

CU505 UTILITY DETAILS 5

CU506 UTILITY DETAILS 6

HANGAR AMU - VOLUME 1 - CIVIL/INFRASTRUCTURE DRAWING LIST

NUMBER NAME

GC001 CIVIL LEGEND AND ABBREVIATIONS

GC002 LOCATION AND VICINITY MAP

GC003 SITE ACCESS AND HAUL ROUTE

GC004 CONSTRUCTION ACCESS AND LOCATION PLAN

GC005 STAGING AND LAYDOWN PLAN

GC006 GENERAL CONSTRUCTION NOTES

GC007 GENERAL CONSTRUCTION NOTES

GC008 GENERAL CONSTRUCTION NOTES

GC009 CIVIL GENERAL NOTES

GC010 OVERALL TRAFFIC PLAN

GC011 BORROW PIT LOCATION

GC012 BORROW PIT B-40

GC501 GENERAL DETAILS 1

GC502 GENERAL DETAILS 2

B-100 BORING LOCATION PLAN

V-100 SURVEY LIMITS

V-101 EXISTING CONDITION GRID 1

V-102 EXISTING CONDITION GRID 2

V-103 EXISTING CONDITION GRID 3

V-104 EXISTING CONDITION GRID 4

V-105 EXISTING CONDITION GRID 5

V-106 EXISTING CONDITION GRID 6

V-107 EXISTING CONDITION GRID 7

V-108 EXISTING CONDITION GRID 8

V-109 EXISTING CONDITION GRID 9

V-110 EXISTING CONDITION GRID 10

V-111 EXISTING CONDITION GRID 11

V-112 EXISTING CONDITION GRID 12

V-113 EXISTING CONDITION GRID 13

V-114 EXISTING CONDITION GRID 14

CD100 OVERALL DEMOLITION PLAN

CD101 DEMOLITION PLAN GRID 1

CD102 DEMOLITION PLAN GRID 2

CD103 DEMOLITION PLAN GRID 3

CD104 DEMOLITION PLAN GRID 4

CD105 DEMOLITION PLAN GRID 5

CD106 DEMOLITION PLAN GRID 6

CD108 DEMOLITION PLAN GRID 8

CD109 DEMOLITION PLAN GRID 9

CD110 DEMOLITION PLAN GRID 10

CD112 DEMOLITION PLAN GRID 12

CD113 DEMOLITION PLAN GRID 13

CD114 DEMOLITION PLAN GRID 14

CD120 BUILDING 90731 DEMOLITION PLAN

CD121 BUILDING 90825 DEMOLITION PLAN

CS100 OVERALL SITE PLAN C-130 COMPLEX

CS101 SITE PLAN GRID 1

CS102 SITE PLAN GRID 2

CS103 SITE PLAN GRID 3

CS104 SITE PLAN GRID 4

CS105 SITE PLAN GRID 5

CS106 SITE PLAN GRID 6

CS107 SITE PLAN GRID 7

CS108 SITE PLAN GRID 8

CS109 SITE PLAN GRID 9

CS110 SITE PLAN GRID 10

CS115 PATIO LAYOUT PLAN

CS116 JOINT LAYOUT & REINFORCEMENT PLAN

CS120 BUILDING 90731 SITE PLAN

CS121 BUILDING 90825 SITE PLAN

CS122 SITE PLAN - HANGAR PROJECT FENCE

CS130 BASE BID + BID OPTION POV PARKING

CS131 SITE PLAN - BASE BID + BID OPTION APRON PAVEMENT

CS132 BASE BID + BID OPTION GSE CONCRETE AND AIRFIELD APRON STRIPING

CS150 ATFP PLAN

CS501 SITE DETAILS 1

CS502 SITE DETAILS 2

CS503 SITE DETAILS 3

CS504 SITE DETAILS 4

CS505 SITE DETAILS 5

CS506 SITE DETAILS 6

CS507 SITE DETAILS 7

CS508 SITE DETAILS 8

CS509 SITE DETAILS 9

CS510 SITE DETAILS 10

CS511 SITE DETAILS 11

CP101 PAVEMENT JOINTING PLAN 1

HU

RL

BU

RT

F

IE

LD

, F

LO

RI

DA

H

AN

G

AR

A M

U

PR

O

JE

C T

N O

. F

TE

V1

M O

BI

LE

D

IS

TR

IC

T M

O

BI

LE

, A

LA

BA

M A

Mobile District

US Army Corps of Engineers ®

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

N O

US

A

RM

Y

CO

RP

S O

F

EN

G

IN

EE

RS

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

FILE:

DATE:

W

AR

D P

AR

KW

AY

KA

N

SA

S C

IT

Y, M O

BU

RN

S

M cD

O

NN

EL

L

D

ES

IG

N

ED

B

Y:

D R

AW

N

B Y:

SB

M

T

BY

PL

O

T

SC

AL

E:

SI

ZE

" x

4"

FI

LE

N

AM

E:

C

KD

B Y:

PL

O

T D

AT

E:

D

AT

E:

SO

LI

C

IT

AT

IO

N N

U M

BE

R

PR

O

JE

C

T N

U M

BE

R

C

AD

D C

O D

E:

JU

LY

, 2

W

8-

-R

-0

FT

EV

M

EF

JU

LY

, 2

A.

M

AS

HE

K

7/8/2020 3:40:37 PM

A.

S

NE

TH

EN

A.

S

NE

TH

EN

A.

M

AS

HE

K

G-002-0004

G-

2-

G-002

SH

EE

T

IN

D

EX

HANGAR AMU - VOLUME 1 - STRUCTURAL DRAWING LIST

NUMBER NAME

S-510 STANDARD MASONRY DETAILS

S-511 STANDARD MASONRY DETAILS

S-520 STANDARD STEEL DETAILS

S-521 STANDARD ROOF DECK & JOIST DETAILS

S-522 STANDARD ROOF DECK & JOIST DETAILS

S-525 TRUSS DETAILS

S-526 TRUSS DETAILS

S-527 TRUSS DETAILS

S-528 TRUSS DETAILS

S-529 TRUSS DETAILS

S-530 VERTICAL BRACING CONNECTION DETAILS

S-531 VERTICAL BRACING CONNECTION DETAILS

S-532 VERTICAL BRACING CONNECTION DETAILS

S-533 VERTICAL BRACING CONNECTION DETAILS

S-534 SWAY FRAME CONNECTION DETAILS

S-535 HORIZONTAL BRACING CONNECTION DETAILS

S-550 FRAMING DETAILS - HANGAR

S-551 FRAMING DETAILS - HANGAR

S-552 FRAMING DETAILS - HANGAR

S-553 FRAMING DETAILS - HANGAR

S-554 FRAMING DETAILS - HANGAR

S-560 FRAMING DETAILS - ADMIN/SHOP

S-561 FRAMING DETAILS - ADMIN/SHOP

S-562 FRAMING DETAILS - ADMIN/SHOP

S-563 FRAMING DETAILS - ADMIN/SHOP

S-564 FRAMING DETAILS - ADMIN/SHOP

S-565 FRAMING DETAILS - ADMIN/SHOP

S-566 FRAMING DETAILS - ADMIN/SHOP

S-570 GIRT DETAILS

S-571 GIRT DETAILS

S-572 GIRT DETAILS

S-573 GIRT DETAILS

S-574 GIRT DETAILS

S-575 GIRT DETAILS

S-580 FALL PROTECTION AND CRANE DETAILS

S-581 FALL PROTECTION AND CRANE DETAILS

S-582 FALL PROTECTION AND CRANE DETAILS

S-583 FALL PROTECTION AND CRANE DETAILS

S-585 EXTERIOR STORAGE RACK DETAILS

S-586 EXTERIOR STORAGE RACK DETAILS

S-587 MECHANICAL PLATFORM AND LADDER DETAILS

S-590 HIGH EXPANSION FOAM GENERATOR FRAMING DETAILS

S-595 COLUMN DETAILS

S-596 COLUMN DETAILS

S-600 COLUMN AND FOUNDATION SCHEDULES

HANGAR AMU - VOLUME 1 - STRUCTURAL DRAWING LIST

NUMBER NAME

S-001 GENERAL NOTES

S-002 GENERAL NOTES

S-003 LEGENDS AND ABBREVIATIONS

S-004 WIND ISOMETRIC

S-005 WIND ISOMETRIC

S-006 WIND ISOMETRIC

S-007 WIND ISOMETRIC

S-100 OVERALL FOUNDATION PLAN

S-101 FOUNDATION PLAN - AREA A

S-102 FOUNDATION PLAN - AREA B

S-103 FOUNDATION PLAN - AREA C

S-104 FOUNDATION PLAN - AREA D

S-105 FOUNDATION PLAN - AREA E

S-106 FOUNDATION PLAN - AREA F

S-110 OVERALL SLAB PLAN

S-111 SLAB PLAN - AREA A

S-112 SLAB PLAN - AREA B

S-113 SLAB PLAN - AREA C

S-114 SLAB PLAN - AREA D

S-115 SLAB PLAN - AREA E

S-116 SLAB PLAN - AREA F

S-120 OVERALL LOW ROOF FRAMING PLAN

S-121 LOW ROOF FRAMING PLAN - AREA A

S-122 LOW ROOF FRAMING PLAN - AREA B

S-123 LOW ROOF FRAMING PLAN - AREA C

S-124 LOW ROOF FRAMING PLAN - AREA D

S-125 LOW ROOF FRAMING PLAN - AREA E

S-126 LOW ROOF FRAMING PLAN - AREA F

S-130 OVERALL BOTTOM CHORD FRAMING PLAN

S-131 BOTTOM CHORD FRAMING PLAN - AREA E

S-132 BOTTOM CHORD FRAMING PLAN - AREA F

S-140 OVERALL HIGH ROOF FRAMING PLAN

S-141 HIGH ROOF FRAMING PLAN - AREA E

S-142 HIGH ROOF FRAMING PLAN - AREA F

S-150 OVERALL FALL ARREST AND CRANE LAYOUT PLAN

S-151 CRANE LAYOUT PLAN - AREA D AND E

S-152 FALL ARREST AND CRANE LAYOUT PLAN - AREA E AND F

S-160 OVERALL HANGAR DOOR FRAMING PLAN

S-161 HANGAR DOOR FRAMING PLANS

S-170 OVERALL EXTERIOR STORAGE RACK AND CANOPY PLAN

S-171 EXTERIOR STORAGE RACK FOUNDATION PLANS

S-172 EXTERIOR STORAGE RACK FRAMING PLANS

S-173 EXTERIOR STORAGE RACK ROOF FRAMING PLANS

S-174 CANOPY FOUNDATION AND ROOF FRAMING PLAN

S-180 FRAMING AND GIRT ELEVATIONS PLAN

S-185 MASONRY WALL ELEVATIONS PLAN

S-200 FRAMING ELEVATIONS GRID A

S-201 FRAMING ELEVATIONS GRID B

S-202 FRAMING ELEVATIONS GRID E AND G

S-203 FRAMING ELEVATIONS GRID F AND J

S-204 FRAMING ELEVATIONS GRID K

S-205 FRAMING ELEVATIONS GRID 10 AND 11

S-206 FRAMING ELEVATIONS GRID 19 AND 20

S-207 FRAMING ELEVATIONS

S-208 FRAMING ELEVATIONS

S-210 GIRT ELEVATIONS GRID A

S-211 GIRT ELEVATIONS GRID B

S-212 GIRT ELEVATIONS GRID K

S-213 GIRT ELEVATIONS GRID 10 AND 11

S-214 GIRT ELEVATIONS GRID 19 AND 20

S-215 GIRT ELEVATIONS

S-216 GIRT ELEVATIONS

S-220 MASONRY WALL ELEVATIONS

S-221 MASONRY WALL ELEVATIONS

S-222 MASONRY WALL ELEVATIONS

S-223 MASONRY WALL ELEVATIONS

S-224 MASONRY WALL ELEVATIONS

S-225 MASONRY WALL ELEVATIONS

S-400 MECHANICAL PLATFORM ENLARGED PLANS

S-401 COMM ROOM ENLARGED SLAB PLAN AND DETAILS

S-500 STANDARD CONCRETE DETAILS

S-501 STANDARD CONCRETE DETAILS

S-502 STANDARD CONCRETE DETAILS

S-503 HANGAR DOOR TRACK DETAILS

S-504 HANGAR DOOR TRACK DETAILS

S-505 FOUNDATION DETAILS

S-506 FOUNDATION DETAILS

S-507 FOUNDATION DETAILS

S-508 FOUNDATION DETAILS

R L

B U

R T

F

IE

L D

F

L O

R

ID

A H

A N

G A

R

A M

U P

R O

J E

C T

N O

F

T E

V

M O

B

IL

E D

IS

T

R

IC

T M

O B

IL

E

A

L A

B A

M A

Mobile District

US Army Corps of

Engineers ®

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R N

O

U S

A R

M Y

C O

R P

S

G

IN

E E

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

FILE:

DATE:

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y

M O

B U

R N

S

M c D

O N

N E

L L

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S B

M T

B Y

P L

O T

S C

A L E

S

IZ

E x

F

IL

E N

A M

E

C K

D B

Y

P L

O T

D A

T E

D A

T E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

P R

O J E

C T

N U

M B

E R

C A

D D

C O

D E

J U

L Y

W

-2

-R

-0

F T

E V

M E

F

JU

L

Y

A

M A

S H

E K

8/10/2020 8:13:21 AM

A

S N

E T

H E

N

A

S N

E T

H E

N A

M

A S

H E

K

G-003-0004

G -0

-0

G-003

S H

E E

T I N

D E

X

HANGAR AMU - VOLUME 2 - ARCHITECTURAL DRAWING LIST

NUMBER NAME

A-542 CASEWORK DETAILS

A-543 MISCELLANEOUS DETAILS

A-551 ENLARGED LADDER ELEVATIONS & DETAILS

A-552 ENLARGED LADDER ELEVATIONS & DETAILS

A-561 CEILING DETAILS

A-571 ROOF DETAILS

A-572 ROOF HATCH DETAILS

A-573 PATIO CANOPY DETAILS

A-601 DOOR SCHEDULE

A-602 DOOR SCHEDULE

A-603 DOOR SCHEDULE

A-621 DOOR DETAILS

A-622 DOOR DETAILS

A-623 DOOR DETAILS

A-631 HANGAR DOOR DETAILS

A-632 HANGAR DOOR SECTIONS

A-641 SLIDING DOOR DETAILS

A-642 SLIDING DOOR SECTIONS

A-651 WINDOW, LOUVER, AND TRANSLUCENT WALL PANEL SCHEDULE AND TYPES

A-661 WINDOW DETAILS

A-671 LOUVER DETAILS

A-681 TRANSLUCENT WALL PANEL DETAILS

A-701 ROOM FINISH SCHEDULE

A-702 ROOM FINISH LEGEND & GENERAL NOTES

A-711 FINISH PLAN AREA - A

A-712 FINISH PLAN AREA - B

A-713 FINISH PLAN AREA - C

A-714 FINISH PLAN AREA - D

A-715 FINISH PLAN AREA - E

A-716 FINISH PLAN AREA - F

A-721 SIGNAGE PLAN AREA - A

A-722 SIGNAGE PLAN AREA - B

A-723 SIGNAGE PLAN AREA - C

A-724 SIGNAGE PLAN AREA - D

A-725 SIGNAGE PLAN AREA - E

A-726 SIGNAGE PLAN AREA - F

A-741 SIGNAGE SCHEDULE

A-742 SIGNAGE DETAILS

A-743 SIGNAGE DETAILS

A-744 SIGNAGE DETAILS

A-751 INTERIOR ELEVATIONS

I-010 OVERALL GROUND FLOOR FURNITURE PLAN

I-011 FF&E GENERAL NOTES AND LEGEND

I-101 FURNITURE PLAN AREA - A

I-102 FURNITURE PLAN AREA - B

I-103 FURNITURE PLAN AREA - C

I-104 FURNITURE PLAN AREA - D

I-105 FURNITURE PLAN AREA - E

I-106 FURNITURE PLAN AREA - F

F-001 LIFE SAFETY CODE AND CRITERIA

F-002 CODE COMPIANCE SITE PLAN

F-003 OVERALL LIFE SAFETY PLAN

F-004 ENLARGED LIFE SAFETY PLAN - AREA A

F-005 ENLARGED LIFE SAFETY PLAN - AREA C

HANGAR AMU - VOLUME 2 - ARCHITECTURAL DRAWING LIST

NUMBER NAME

A-001 ARCHITECTURAL LEGEND AND ABBREVIATIONS

A-002 ARCHITECTURAL GENERAL NOTES

A-003 ABA INFORMATION

A-004 ABA INFORMATION

A-101 OVERALL FLOOR PLAN

A-102 OVERALL REFLECTED CEILING PLAN

A-103 OVERALL ROOF PLAN

A-104 AIRCRAFT CLEARANCE REQUIREMENTS PLAN

A-105 AIRCRAFT CLEARANCE REQUIREMENTS SECTION

A-111 FLOOR PLAN - AREA A

A-112 FLOOR PLAN - AREA B

A-113 FLOOR PLAN - AREA C

A-114 FLOOR PLAN - AREA D

A-115 FLOOR PLAN - AREA E

A-116 FLOOR PLAN - AREA F

A-121 REFLECTED CEILING PLAN - AREA A

A-122 REFLECTED CEILING PLAN - AREA B

A-123 REFLECTED CEILING PLAN - AREA C

A-124 REFLECTED CEILING PLAN - AREA D

A-125 REFLECTED CEILING PLAN - AREA E

A-126 REFLECTED CEILING PLAN - AREA F

A-131 AIR BARRIER ENCLOSURE

A-132 AIR BARRIER SECTIONS

A-141 EXPANSION JOINT PLAN AND ISOMETRIC VIEWS

A-142 BRICK LEDGE PLAN AND ELEVATIONS

A-201 EXTERIOR BUILDING ELEVATIONS

A-202 EXTERIOR BUILDING ELEVATIONS

A-203 SECTION ELEVATIONS

A-211 ENLARGED EXTERIOR BUILDING ELEVATIONS

A-212 ENLARGED EXTERIOR BUILDING ELEVATIONS

A-213 ENLARGED EXTERIOR BUILDING ELEVATIONS

A-214 ENLARGED EXTERIOR BUILDING ELEVATIONS

A-215 ENLARGED EXTERIOR HIDDEN ELEVATIONS

A-301 BUILDING SECTIONS

A-302 BUILDING SECTIONS

A-311 WALL SECTIONS

A-312 WALL SECTIONS

A-313 WALL SECTIONS

A-314 WALL SECTIONS

A-315 WALL SECTIONS

A-316 WALL SECTIONS

A-317 WALL SECTIONS

A-318 WALL SECTIONS

A-319 WALL SECTIONS

A-320 WALL SECTIONS

A-321 WALL SECTIONS

A-322 EXTERIOR STORAGE DETAILS

A-323 EXTERIOR STORAGE DETAILS

A-401 ENLARGED FLOOR PLANS

A-402 ENLARGED FLOOR PLANS & ELEVATIONS

A-421 TOILET PLANS AND ELEVATIONS

A-422 TOILET PLANS AND ELEVATIONS

A-423 TOILET PLANS AND ELEVATIONS

A-424 TOILET ELEVATIONS

A-425 TOILET ELEVATIONS

A-431 ENLARGED EQUIPMENT PLATFORM PLANS

A-432 ENLARGED EQUIPMENT PLATFORM PLANS

A-441 EXTERIOR STORAGE PLANS

A-442 EXTERIOR STORAGE PLANS

A-451 DEMOUNTABLE PARTITION PLANS

A-452 DEMOUNTABLE PARTITION PLANS

A-501 PARTITION TYPES

A-502 PARTITION TYPE DETAILS

A-503 PENETRATION DETAILS

A-504 PENETRATION DETAILS

A-521 SECTION DETAILS

A-522 SECTION DETAILS

A-523 SECTION DETAILS

A-524 SECTION DETAILS

A-525 SECTION DETAILS

A-526 SECTION DETAILS

A-527 SECTION DETAILS

A-528 SECTION DETAILS

A-529 SECTION DETAILS

A-530 SECTION DETAILS

A-531 SECTION DETAILS

A-532 SECTION DETAILS

A-533 SECTION DETAILS

A-541 CASEWORK DETAILS

HANGAR AMU - VOLUME 2 - FIRE PROTECTION DRAWING LIST

NUMBER NAME

FA001 FIRE ALARM NOTES, LEGEND AND ABBREVIATIONS

FA101 FIRE ALARM AND MASS NOTIFICATION PLAN - AREA A

FA102 FIRE ALARM AND MASS NOTIFICATION PLAN - AREA B

FA103 FIRE ALARM AND MASS NOTIFICATION PLAN - AREA C

FA104 FIRE ALARM AND MASS NOTIFICATION PLAN - AREA D

FA105 FIRE ALARM AND MASS NOTIFICATION PLAN - AREA E

FA106 FIRE ALARM AND MASS NOTIFICATION PLAN - AREA F

FA501 FIRE ALARM DETAILS

FA601 FIRE ALARM ONE-LINE DIAGRAM

FA602 FIRE ALARM MATRIX

FA603 (RSFACU) RELEASING SYSTEM ALARM CONTROL PANEL

FX001 FIRE SUPPRESSION NOTES, LEGEND AND ABBREVIATIONS

FX101 FIRE SUPPRESSION PLAN - AREA A

FX102 FIRE SUPPRESSION PLAN - AREA B

FX103 FIRE SUPPRESSION PLAN - AREA C

FX104 FIRE SUPPRESSION PLAN - AREA D

FX105 FIRE SUPPRESSION PLAN - AREA E

FX106 FIRE SUPPRESSION PLAN - AREA F

FX501 FIRE SUPPRESSION RISER DETAILS

FX502 FIRE SUPPRESSION SIGNAGE

FX601 FIRE SUPPRESSION RISER DIAGRAM

R L

B U

R T

F

IE

L D

F

L O

R

ID

A H

A N

G A

R

A M

U P

R O

J E

C T

N O

F

T E

V

M O

B

IL

E D

IS

T

R

IC

T M

O B

IL

E

A

L A

B A

M A

Mobile District

US Army Corps of

Engineers ®

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R N

O

U S

A R

M Y

C O

R P

S

G

IN

E E

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

FILE:

DATE:

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y

M O

B U

R N

S

M c D

O N

N E

L L

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S B

M T

B Y

P L

O T

S C

A L E

S

IZ

E x

F

IL

E N

A M

E

C K

D B

Y

P L

O T

D A

T E

D A

T E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

P R

O J E

C T

N U

M B

E R

C A

D D

C O

D E

J U

L Y

W

-2

-R

-0

F T

E V

M E

F

JU

L

Y

A

M A

S H

E K

8/10/2020 8:20:58 AM

A

S N

E T

H E

N

A

S N

E T

H E

N A

M

A S

H E

K

G-004-0004

G -0

-0

G-004

S H

E E

T I N

D E

X

HANGAR AMU - VOLUME 3 - MECHANICAL DRAWING LIST

NUMBER NAME

M-001 MECHANICAL NOTES, LEGEND, SYMBOLS & ABBREVIATIONS

M-100 MECHANICAL PLAN - OVERALL

M-101 HVAC PLAN - AREA A

M-102 HVAC PLAN - AREA B

M-103 HVAC PLAN - AREA C

M-104 HVAC PLAN - AREA D

M-105 HVAC PLAN - AREA E

M-106 HVAC PLAN - AREA F

M-111 HVAC PIPING PLAN - AREA A

M-112 HVAC PIPING PLAN - AREA B

M-113 HVAC PIPING PLAN - AREA C

M-115 HVAC PIPING PLAN - AREA E

M-116 HVAC PIPING PLAN - AREA F

M-301 MECHANICAL SECTIONS

M-302 MECHANICAL SECTIONS

M-303 MECHANICAL SECTIONS

M-304 MECHANICAL SECTIONS

M-401 MECHANICAL ENLARGED PLAN

M-402 MECHANICAL ENLARGED PLAN

M-501 MECHANICAL DETAILS

M-502 MECHANICAL DETAILS

M-503 MECHANICAL DETAILS

M-504 MECHANICAL DETAILS

M-505 MECHANICAL DETAILS

M-506 MECHANICAL DETAILS

M-601 MECHANICAL SCHEDULES

M-602 MECHANICAL SCHEDULES

M-603 MECHANICAL SCHEDULES

M-604 MECHANICAL SCHEDULES

M-610 CHILLED WATER FLOW DIAGRAM

M-611 AHU-101 AIRFLOW DIAGRAM

M-612 AHU-102 AIRFLOW DIAGRAM (1/2)

M-613 AHU-102 AIRFLOW DIAGRAM (2/2)

M-614 AHU-103 AIRFLOW DIAGRAM

M-701 CONTROL LEGEND

M-702 SYSTEMS ARCHITECTURE AND MISCELLANEOUS CONTROLS

M-703 CONTROLS SCHEMATIC - AHU-101

M-704 CONTROL POINTS - AHU-101

M-705 CONTROLS - VAV TERMINAL UNITS

M-706 CONTROLS - HANGAR BAY

M-707 CONTROLS SCHEMATIC - MUA-101

M-708 CONTROLS POINTS - MUA-101

M-709 CONTROLS SCHEMATIC - MAU-102

M-710 CONTROLS SCHEMATIC - EF-101

M-711 CONTROLS SCHEMATIC - EF-103

M-712 CONTROLS - AIR COOLED CHILLED WATER SYSTEM

M-713 AC CHILLED WATER PRIMARY/SECONDARY SEQUENCE OF OPERATION

M-714 POINTS LIST - AIR COOLED CHILLED WATER SYSTEM

HANGAR AMU - VOLUME 3 - PLUMBING DRAWING LIST

NUMBER NAME

P-001 PLUMBING NOTES, LEGEND, SYMBOLS & ABBREVIATIONS

P-100 UNDERGROUND PLUMBING PLAN - OVERALL

P-101 UNDERGROUND PLUMBING PLAN - AREA A

P-102 UNDERGROUND PLUMBING PLAN - AREA B

P-103 UNDERGROUND PLUMBING PLAN - AREA C

P-104 UNDERGROUND PLUMBING PLAN - AREA D

P-105 UNDERGROUND PLUMBING PLAN - AREA E

P-106 UNDERGROUND PLUMBING PLAN - AREA F

P-110 ABOVE GROUND PLUMBING PLAN - OVERALL

P-111 ABOVE GROUND PLUMBING PLAN - AREA A

P-112 ABOVE GROUND PLUMBING PLAN - AREA B

P-113 ABOVE GROUND PLUMBING PLAN - AREA C

P-114 ABOVE GROUND PLUMBING PLAN - AREA D

P-115 ABOVE GROUND PLUMBING PLAN - AREA E

P-116 ABOVE GROUND PLUMBING PLAN - AREA F

P-401 PLUMBING PARTIAL PLAN

P-402 PLUMBING ENLARGED PLAN

P-403 PLUMBING ENLARGED PLAN

P-501 PLUMBING DETAILS

P-502 PLUMBING DETAILS

P-503 PLUMBING DETAILS

P-601 PLUMBING SCHEDULES

P-602 PLUMBING SCHEDULES

P-901 WASTE AND VENT RISER DIAGRAM

P-902 WASTE AND VENT RISER DIAGRAM

P-903 WASTE AND VENT RISER DIAGRAM

P-904 DOMESTIC WATER RISER DIAGRAM

P-905 DOMESTIC WATER RISER DIAGRAM

P-906 DOMESTIC WATER RISER DIAGRAM

P-907 NATURAL GAS RISER DIAGRAM

P-908 NATURAL GAS RISER DIAGRAM

P-909 COMPRESSED AIR RISER DIAGRAM

HANGAR AMU - VOLUME 3 - TELECOMMUNICATION DRAWING LIST

NUMBER NAME

T-001 TELECOMMUNICATIONS LEGEND

TS101 COMMUNICATION SITE PLAN

TS102 COMMUNICATION SITE PLAN

T-101 TELECOMMUNICATIONS PLAN - AREA A

T-102 TELECOMMUNICATIONS PLAN - AREA B

T-103 TELECOMMUNICATIONS PLAN - AREA C

T-104 TELECOMMUNICATIONS PLAN - AREA D

T-105 TELECOMMUNICATIONS PLAN - AREA E

T-106 TELECOMMUNICATIONS PLAN - AREA F

T-401 TELECOMMUNICATIONS ENLARGED PLANS

T-402 TELECOMMUNICATIONS ENLARGED PLANS

T-501 TELECOMMUNICATIONS DETAILS

T-502 TELECOMMUNICATION DETAILS

T-503 TELECOMMUNICATIONS DETAILS

T-504 TELECOMMUNICATIONS DETAILS

T-601 TELECOMMUNICATIONS RISERS

T-602 TELECOMMUNICATIONS SCHEDULES

HANGAR AMU - VOLUME 3 - ELECTRICAL DRAWING LIST

NUMBER NAME

E-001 ELECTRICAL SYMBOLS LEGEND

E-002 ELECTRICAL SYMBOLS LEGEND

E-010 OVERALL HAZARDOUS LOCATION PLAN

ES101 SITE PLAN

ES501 SITE DETAILS

ES502 SITE DETAILS

EG101 GROUNDING PLAN

EG102 LIGHTNING PROTECTION PLAN

EG501 GROUNDING DETAILS

EG502 GROUNDING DETAILS

EG601 GROUNDING SCHEMATIC

EL101 LIGHTING PLAN - AREA A

EL102 LIGHTING PLAN - AREA B

EL103 LIGHTING PLAN - AREA C

EL104 LIGHTING PLAN - AREA D

EL105 LIGHTING PLAN - AREA E

EL106 LIGHTING PLAN - AREA F

EL301 LIGHTING SECTIONS

EL401 LIGHTING ENLARGED PLANS

EL501 LIGHTING DETAILS

EL502 LIGHTING DETAILS

EL503 LIGHTING DETAILS - BID OPTION

EL504 LIGHTING DETAILS

EL505 LIGHTING DETAILS

EL506 LIGHTING DETAILS

EL601 LIGHTING CONTROL MATRIX

EL701 LIGHT FIXTURE SCHEDULE

EP101 POWER PLAN - AREA A

EP102 POWER PLAN - AREA B

EP103 POWER PLAN - AREA C

EP104 POWER PLAN - AREA D

EP105 POWER PLAN - AREA E

EP106 POWER PLAN - AREA F

EP401 POWER ENLARGED PLANS

EP402 POWER ENLARGED PLANS

EP403 POWER ELEVATIONS

EP501 POWER DETAILS

EP502 POWER DETAILS

EP503 POWER DETAILS

EP504 POWER DETAILS

EP601 ELECTRICAL ONE-LINE DIAGRAM

EP602 ELECTRICAL ONE-LINE DIAGRAM SCHEDULES

EP701 PANELBOARD SCHEDULES

EP702 PANELBOARD SCHEDULES

EP703 PANELBOARD SCHEDULES

EP704 PANELBOARD SCHEDULES

EP705 PANELBOARD SCHEDULES

EP706 PANELBOARD SCHEDULES

EP707 PANELBOARD SCHEDULES

EP708 MECHANICAL COORDINATION SCHEDULE

EP709 MECHANICAL COORDINATION SCHEDULE

RIGID INSULATION

FACE BRICK

PLYWOOD

CONCRETE

MASONRY UNIT

CONCRETE

UNDISTURBED

EARTH

GROUT OR

GYPSUM BOARD

STEEL OR

FERROUS METALS

GRAVEL

FINISHED WOOD

BATT INSULATION

DIMENSION

LUMBER

METAL STUD WALL

BACKER ROD AND

SEALANT

ALUMINUM OR

NON-FERROUS METALS

SAND, PLASTER, OR

PORTLAND CEMENT

COMPACTED

FILL

TERRAZZO

GRASS

MASONRY

PARTICLE BOARD

GLUED-LAMINATED WOOD

PLASTIC LAMINATE

SECTION, DETAIL, AND ELEVATION SYMBOL IDENTIFIERS:

DRAWING SEQUENCE NUMBER INDICATES

WHERE TITLE IS LOCATED (MAY NOT BE

PRESENT IF CALLOUT AND TITLE ARE ON

THE SAME DRAWING)

LETTER OR NUMBER

DESIGNATOR

ONE OR TWO CHARACTER DISCIPLINE

DESIGNATOR (MAY NOT BE PRESENT IF

CALLOUT AND TITLE ARE ON DRAWINGS

WITHIN THE SAME DISCIPLINE)

WALL OR DETAIL SECTION CALLOUT EXAMPLE:

DETAIL CALLOUT EXAMPLE:

ELEVATION CALLOUT EXAMPLE:

SECTION, DETAIL, AND ELEVATION TITLE EXAMPLE:

NORTH ARROW EXAMPLE:

SIM

A-888

LETTER OR NUMBER

INDICATES DETAIL

SHEET NUMBER WHERE

SECTION IS DRAWN

LETTER OR NUMBER

INDICATES DETAIL

SHEET NUMBER WHERE

SECTION IS DRAWN

SIM

A-888

BUILDING SECTION CALLOUT EXAMPLE:

VIEW REFERENCE EXAMPLE:

NUMBER INDICATES DETAIL

SHEET NUMBER WHERE SECTION IS DRAWN

LETTER OR NUMBER

INDICATES DETAIL

SHEET NUMBER WHERE

DETAIL IS DRAWN

A1 View Name 1/8" = 1'-0" 0 4' 8' 16'

VIEW SCALE

VIEW SCALE BAR

TRUE

NORTH

VIEW TITLE

LETTER AND NUMBER INDICATES

SHEET GRID COORDINATE OF VIEW

N

A101

A1

A1 A1

A1

A101

A1

EXTERIOR ELEVATION INTERIOR ELEVATION

DRAWING NUMBER WHERE

ELEVATION IS DRAWN

LETTER AND NUMBER

INDICATES ELEVATION

A1

A101

A1

A101

A1

A101

A1

A101

X

X-XXX

SIMILAR DETAIL

UP

DN

ISOMETRIC DIRECTION ARROW:

NEW DOOR

NEW WALL (RE: PARTITION TYPE)

PLAN LEGEND:

ROOM NAME

ROOM NUMBER

PARTITION TYPE

DOOR NUMBER

WINDOW TYPE

GLAZING TYPE

LOUVER TAG

GRID BUBBLE AND LINE

TOILET ACCESSORY TAG

L01

T-01

WORK

1' - 0" A.F.F.

FURNITURE SYSTEM TAG

ROOM NAME

CEILING HEIGHT TAG

S2AA

W1

1i SIGNAGE TAG

H U

R L

B U

R T

F

IE

L D

F

L O

R

ID

A H

A N

G A

R

A M

U P

R O

J E

C T

N O

F

T E

V

M O

B

IL

E D

IS

T

R

IC

T M

O B

IL

E

A

L A

B A

M A

Mobile District

US Army Corps of

Engineers ®

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R N

O

U S

A R

M Y

C O

R P

S

G

IN

E E

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

FILE:

DATE:

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y

M O

B U

R N

S

M c D

O N

N E

L L

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S B

M T

B Y

P L

O T

S C

A L E

S

IZ

E x

F

IL

E N

A M

E

C K

D B

Y

P L

O T

D A

T E

D A

T E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

P R

O J E

C T

N U

M B

E R

C A

D D

C O

D E

J U

L Y

W

-2

-R

-0

F T

E V

M E

F

JU

L

Y

A

M A

S H

E K

7/6/2020 12:28:53 PM

A s in d ic a te d

T

K

IM

C

L A

U B

E R

T H

A

C O

H E

N

A-001-0004

A -0

-0

A-001

A R

C H

IT

E

C T

U R

A L L

E G

E N

D A

N D

A B

B R

E V

IA

T

IO

N

S

OFF OFFICE

OIC OFFICER IN COMMAND

OPNG OPENING

OPP OPPOSITE

-P-

PA PUBLIC ADDRESS

PERIM PERIMETER

PKG PACKAGE

PL PLATE

PLMB PLUMBING

PLYWD PLYWOOD

POTFF PROTECTION OF THE FORCE & FAMILY

PROJ PROJECT

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PVC POLYVINYL CHLORIDE

-R-

R RADIUS

R/A RETURN AIR

RCP REFLECTIVE CEILING PLAN

RD ROOF DRAIN

RECP RECEPTACLE

REFER REFERENCE

REINF REINFORCED

REQ'D REQUIRED

REV REVISION

RH RIGHT HAND

RO ROUGH OPENING

-S-

S SOUTH

S/A SUPPLY AIR

SCHED SCHEDULE

SECT SECTION

SF SQUARE FOOT

SID STRUCTURAL INTERIOR DESIGN

SIM SIMILAR

SNC SIERRA NEVADA CORPORATION

SPEC SPECIFICATION

SPO SYSTEM PROGRAM OFFICE

SQ SQUARE, AS IN "SQ FT"

SSMR STANDING SEAM METAL ROOF

STC SOUND TRANSMISSION COEFFICIENT

STD STANDARD

STOR STORAGE

STRUCT STRUCTURAL

SUPP SUPPORT

SUSP SUSPENDED

SYS SYSTEM

-T-

TD TRENCH DRAIN

TECH TECHNICAL

THRU THROUGH

TLT TOILET

TO TOP OF, AS IN "TO STEEL"

TYP TYPICAL

-U-

UL UNDERWRITERS LABORATORY

UNO UNLESS NOTED OTHERWISE

UTIL UTILITY

-V-

VENT VENTILATE, VENTILATOR

VERT VERTICAL

VEST VESTIBULE

VOL VOLUME

-W-

W WEST, WIDTH

W/ WITH

W/O WITHOUT

WC WATER CLOSET

WD WOOD

WH WATER HEATER

WT WEIGHT

FE FIRE EXTINGUISHER WITH WALL BRACKET

FEC FIRE EXTINGUISHER CABINET

FF FINISH FLOOR

FF&E FURNITURE, FIXTURES & EQUIPMENT

FHC FIRE HOSE CABINET (WITH EXTINGUISHER &

BRACKET)

FHR FIRE HOSE REEL (WITH EXTINGUISHER &

BRACKET)

FIN FINISHED, FINISH

FLR FLOOR

FSR FACILITY SERVICE REQUEST

FT FEET / FOOT

FV FIELD VERIFY

°F FAHRENHEIT

-G-

GA GAUGE

GALV GALVANIZED

GL GIRT LINE

GRTG GRATING

GYP GYPSUM

GYP BD GYPSUM BOARD

-H-

H HIGH

HD HAND

HDWR HARDWARE

HM HOLLOW METAL

HORIZ HORIZONTAL

HT HEIGHT

HVAC HEATING, VENTILATION & AIR CONDITIONING

HYDRO HYDROLICS

-I-

ID INSIDE DIAMETER

IN INCH

INSUL INSULATION

INT INTERIOR

INTERM INTERMEDIATE

ISU INTERNAL STABILITY UNIT

-J-

JAN JANITOR'S CLOSET

-L-

L LEFT, LONG, LENGTH

LAB LABORATORY

LAT LATITUDE

LAV LAVATORY

LB or # POUND

LH LEFT HAND

LONG LONGITUDE

LVR LOUVER

-M-

M METER

MACH MACHINE

MAINT MAINTENANCE

MAS MASONRY

MATL MATERIAL

MAX MAXIMUM

MECH MECHANICAL

MFR MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

MM MILLIMETER

MO MASONRY OPENING

MTD MOUNTED

MTL METAL

-N-

N NORTH

N/A NOT APPLICABLE

NCOIC NON-COMMISSIONED OFFICER IN CHARGE

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NTP NOTICE TO PROCEED

NTS NOT TO SCALE

-O-

OC ON CENTER

OD OUTSIDE DIAMETER

-A-

A/E ARCHITECT/ENGINEER

ACOUST ACOUSTICAL

ADJ ADJACENT, ADJUSTABLE

AFETS AIR FORCE ENGINEERING & TECHNICAL

SERVICE

AFF ABOVE FINISH FLOOR

AHJ AUTHORITY HAVING JURISDICTION

ALT ALTERNATE

ALUM ALUMINUM

APPROX APPROXIMATE

ARCH ARCHITECTURE, ARCHITECT

ASST ASSISTANT

-B-

BD BOARD

BITUM BITUMINOUS

BLDG BUILDING

BLKG BLOCKING

BO BOTTOM OF, AS IN "BO STEEL"

BTWN BETWEEN

-C-

CAB CABINET

CCTV CLOSED CIRCUIT TELEVISION

CID COMPREHENSIVE INTERIOR DESIGN

CJ CONTROL JOINT, CONSTRUCTION JOINT

CL CENTER LINE

CLG CEILING

CLR CLEAR

CMU CONCRETE MASONRY UNIT

CO CLEANOUT

COL COLUMN

COMM COMMUNICATION

CONC CONCRETE

CONF CONFERENCE

CONSTR CONSTRUCTION

CONT CONTINUOUS

CONTR CONTRACT, CONTRACTOR

COORD COORDINATE

COR CONTRACTING OFFICER'S REPRESENTATIVE

CORR CORRUGATED OR CORRIDOR

CTK CONSOLIDATED TOOL KIT

CU CUBIC

°C CELSIUS

-D-

DBL DOUBLE

DEMO DEMOLITION

DESCR DESCRIPTION

DET DETAIL

DIA DIAMETER

DIAG DIAGONAL

DIM DIMENSION

DN DOWN

DR DOOR

DS DOWNSPOUT

DWG DRAWING

-E-

E EAST

EA EACH

EEW EMERGENCY EYEWASH

EEWS EMERGENCY EYEWASH & SHOWER

EF EXHAUST FAN

EJ EXPANSION JOINT

EL ELEVATION, AS IN HEIGHT

ELAST ELASTOMERIC

ELEC ELECTRIC / ELECTRICAL

ELEV ELEVATOR, OR ELEVATION AS IN NORTH ELEV

EQ EQUAL

EQUIP EQUIPMENT

ETC AND SO FORTH (ETCETERA)

EW EACH WAY

EWC ELECTRIC WATER COOLER

EXH EXHAUST

EXIST EXISTING

EXP EXPANSION

EXT EXTERIOR

-F-

FD FLOOR DRAIN

FDN FOUNDATION

ABBREVIATIONS

SEE ADDITIONAL FINISH MATERIAL

ABBREVIATIONS IN THE MATERIAL LEGENDPLAN LEGENDCALL OUT IDENTIFICATION MATERIAL SYMBOLS

R L

B U

R T

F

IE

L D

F

L O

R

ID

A H

A N

G A

R

A M

U P

R O

J E

C T

N O

F

T E

V

M O

B

IL

E D

IS

T

R

IC

T M

O B

IL

E

A

L A

B A

M A

Mobile District

US Army Corps of

Engineers ®

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R N

O

U S

A R

M Y

C O

R P

S

G

IN

E E

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

FILE:

DATE:

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y

M O

B U

R N

S

M c D

O N

N E

L L

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S B

M T

B Y

P L

O T

S C

A L E

S

IZ

E x

F

IL

E N

A M

E

C K

D B

Y

P L

O T

D A

T E

D A

T E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

P R

O J E

C T

N U

M B

E R

C A

D D

C O

D E

J U

L Y

W

-2

-R

-0

F T

E V

M E

F

JU

L

Y

A

M A

S H

E K

7/6/2020 12:28:56 PM

T

K

IM

C

L A

U B

E R

T H

A

C O

H E

N

A-002-0004

A -0

-0

A-002

A R

C H

IT

E

C T

U R

A L G

E N

E R

A L

N O

T E

S

ARCHITECTURAL GENERAL NOTES

36. CONTROL JOINTS (CJ) SHALL BE INSTALLED AT ALL PARTITIONS. CJ AT GYPSUM PARTITIONS

SHALL BE MAXIMUM 30'-0" OC. CJ AT CONCRETE MASONRY UNIT PARTITIONS SHALL BE

MAXIMUM 20'-0" OC. UNLESS OTHERWISE NOTED ON DRAWINGS REFER TO ELEVATION

DRAWINGS FOR EXTERIOR CONTROL JOINT LOCATIONS. REVIEW CJ LOCATIONS WITH

ARCHITECT'S OR C.O.R.'S PRIOR TO INSTALLATION.

37. NON-BEARING PARTITIONS SHALL BE ISOLATED FROM THE BUILDING STRUCTURE TO PREVENT

TRANSFER OF BUILDING LOADS FROM THE STRUCTURE TO THE PARTITIONS.

38. PRIOR TO BEGINNING ANY WORK, NOTIFY COR OF ANY EXISTING MATERIALS OBSERVED TO

POSSIBLY CONTAIN ASBESTOS.

39. ALL EXPOSED STEELS ARE PAINTED.

40. REMOVE EXISTING WORK AS INDICATED AND AS REQUIRED TO ACCOMPLISH NEW WORK.

41. WHERE EXISTING FINISHED SURFACES ARE CUT SO THAT A SMOOTH TRANSITION WITH NEW

WORK IS NOT POSSIBLE, TERMINATE EXISTING SURFACE ALONG A STRAIGHT LINE AT A

NATURAL LINE OF DIVISION AND MAKE RECOMMENDATION TO ARCHITECT.

42 PROVIDE WEATHER TIGHT EXPANSION JOINT COVER BETWEEN HANGAR BAY AND LEAN TO.

REFERENCE SHEET A-141 FOR EXPANSION JOINT LOCATIONS & DETAILS

43 THE DIMENSION FROM CENTER OF LADDER RUNG TO ANY SURFACE MOUNTED ELEMENTS OR

WALL OR STURCURE SHALL BE 7 INCH (CLEAR) MININUM. CONTRACTOR SHALL COORDINATE ALL

WALL MOUNTED ELEMENTS FOR LADDER LOCATION.

44 PROVIDE GAP BETWEEN LOAD BEARING CMU & NON-LOAD BEARING CMU. RE: A2/A533 & RE:

STRUCTURAL

1. ALL WORK SHALL COMPLY WITH ALL APPLICABLE CODES AND STANDARDS AS LISTED OR

REFERENCED ON LIFE SAFETY PLAN AND LIFE SAFETY CRITERIA.

2. ALL INTERIOR PARTITION WALL DIMENSIONS ARE TO FINISH FACE OF WALL.

3. DIMENSIONS SHALL GOVERN. DETAILS SHALL GOVERN OVER PLANS AND ELEVATIONS. LARGE

SCALE DETAILS OR PLANS SHALL GOVERN OVER SMALL SCALE DETAILS OR PLANS. DO NOT

SCALE DRAWINGS.

4. THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL EXIT SIGNS, EMERGENCY

LIGHTING SYSTEMS, ALARM SYSTEMS AND AUTOMATIC SPRINKLER SYSTEMS AS REQUIRED BY

APPLICABLE CODES AND STANDARDS.

5. ALL FLOORS SHALL BE INSPECTED FOR DAMAGE, WARPING OR OTHER NOTICEABLE

DEVIATIONS AND PATCHED AND LEVELED PRIOR TO COVERING WITH FLOOR FINISHES.

6. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL MANUFACTURER'S

RECOMMENDED MAINTENANCE PROCEDURES AND SCHEDULES.

7. ANY MANUFACTURER'S OR BRAND NAME PRODUCTS INDICATED OR SPECIFIED ARE DONE SO

TO ESTABLISH A MINIMUM LEVEL OF QUALITY.

8. ALL CONSTRUCTION SHALL MEET OR EXCEED LOCAL INDUSTRY STANDARDS. DETAILS ARE

PROVIDED TO INDICATE MINIMUM QUALITY AND TO GIVE STANDARDS OF CONSTRUCTION. IF A

CONDITION IS NOT SPECIFICALLY DETAILED, SUBMIT A SIMILAR DETAIL FOR GUIDE AND

APPROVAL.

9. THE LETTERS I, O, AND Q ARE NOT USED TO INDICATE DETAILS, SECTIONS OR ELEVATIONS.

10. PROVIDE PRESERVATIVE-TREATED WOOD AT ALL LOCATIONS WHERE WOOD IS IN DIRECT

CONTACT WITH CONCRETE OR MASONRY.

11. PROVIDE 3/4" FIRE-RETARDANT TREATED PLYWOOD BACKING AT ALL ELECTRICAL, PHONE, AND

SECURITY SYSTEM PANELS.

12. PROVIDE FIRE-RESISTANT TREATED WOOD BLOCKING FOR SECURE ANCHORAGE OF ALL

SHELVES, RUNNING TRIM, RAILINGS, SUSPENDED ITEMS, DOOR-STOPS, GRAB-BARS, AND

OTHER SIMILAR WOODWORK, HARDWARE, SPECIALTIES, ACCESSORIES, FIXTURES, OR

EQUIPMENT.

13. NOT USED

14. PROVIDE WATER-RESISTANT GYPSUM BOARD AT ALL WET OR UNCONDITIONED AREAS

INCLUDING, BUT NOT LIMITED TO, PARTITIONS BEHIND SINKS. CONTRACTOR TO INSURE THAT

FIRE RATING IS MAINTAINED.

15. PAINT, STAIN, OR COAT ALL EXPOSED SURFACES OF CONSTRUCTION UNLESS NOTED

OTHERWISE OR IF SURFACES ARE PRE-FINISHED.

16. ALL OPENING DIMENSIONS ARE NOMINAL. THE CONTRACTOR SHALL FIELD MEASURE ALL

OPENINGS AND COORDINATE WITH THE APPROPRIATE SUPPLIER FOR ALL DOORS, LOUVERS,

AND WINDOWS.

17. ALL CONDUITS, PLUMBING, PIPING, DUCTWORK, AND OTHER EQUIPMENT EXPOSED TO VIEW

SHALL BE LOCATED PARALLEL OR PERPENDICULAR TO THE STRUCTURAL FRAMING SYSTEM.

18. PROVIDE GALVANIC PROTECTION BETWEEN DISSIMILAR MATERIALS, WHERE REQUIRED.

19. NOT USED.

20. ARCHITECTURAL DETAILS ARE APPLICABLE WHERE INDICATED BY SECTION CUT, BY NOTE, OR

BY DETAIL TITLE. PROVIDE SIMILAR DETAILS AT SIMILAR CONDITIONS UNLESS NOTED

OTHERWISE. THE CONTRACTOR MAY REQUEST A CLARIFICATION IF REQUIRED, OTHERWISE

THE MORE STRINGENT REQUIREMENTS SHALL CONTROL.

21. PROVIDE FIRE-STOPPING SYSTEMS AT TOP OF AND AT ALL PENETRATIONS THROUGH

FIRE-RATED PARTITIONS.

22. SEAL ALL EXTERIOR BUILDING JOINTS AT BOTH THE EXTERIOR AND INTERIOR SURFACES

AGAINST MOISTURE AND AIR INFILTRATION.

23. SEAL AROUND ALL DOOR AND WINDOW FRAMES, COUNTERTOPS, WALL-MOUNTED FIXTURES

AND EQUIPMENT TO ADJACENT WALL SURFACES.

24. THE CONTRACTOR SHALL REVIEW THE DIMENSIONS OF ALL EQUIPMENT IN THE PROJECT

REGARDLESS OF THE SOURCE AND COORDINATE ACCESS TO THE SPACE AND VERIFY CLEAR

FLOOR SPACE IS PROVIDED AS REQUIRED TO ENSURE EASE OF INSTALLATION.

25. ALL WORK MUST BE OF GOOD QUALITY, FREE FROM DEFECTS, AND IN ACCORDANCE WITH THE

REQUIREMENTS OF THE CONTRACT DOCUMENTS.

26. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL PENETRATIONS IN THE

STRUCTURE FOR THE PROPER INSTALLATION OF THE WORK. REFER TO STRUCTURAL

DRAWING FOR SECONDARY FRAMING AND OR REINFORCING REQUIRED AT PENETRATIONS IN

STEEL, CONCRETE OR MASONRY.

27. THE CONTRACTOR SHALL PROVIDE ACCESS DOORS OR PANELS AS REQUIRED FOR SERVICING

OF PIPING, DUCTWORK, CABLE TRAYS, FIRE DAMPERS AND SIMILAR APPLICATIONS. ALL

PROPOSED ACCESS DOOR LOCATIONS TO BE SUBMITTED FOR APPROVAL PRIOR TO

INSTALLATION.

28. PROVIDE ALL HVAC, PLUMBING, GAS OR ELECTRIC SERVICE CONNECTIONS TO CASEWORK,

FIXTURES, SIGNAGE, OR EQUIPMENT INDICATED (WHETHER UNITS ARE INSTALLED BY

CONTRACTOR OR BY OTHERS).

29. BRACE PARTITIONS, SUSPENDED CEILINGS, SOFFITS, SUSPENDED ITEMS, ETC. ONLY TO

STRUCTURAL ELEMENTS ABOVE. DO NOT ANCHOR TO ROOF DECK, PLUMBING / SPRINKLER

PIPES, DUCTWORK, ELECTRICAL CONDUIT OR SIMILAR ELEMENTS.

30. EXTEND ALL FLOORING AND WALL-BASE COMPLETELY INTO RECESSES, UNDER OPEN

COUNTERTOPS, AND BEHIND ALL EQUIPMENT.

31. ALL MATERIALS USED FOR CONSTRUCTION SHALL BE NEW AND UNDAMAGED. THE

CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ALL WORK SHOWN.

32. THE CONTRACTOR SHALL BECOME FULLY ACQUAINTED WITH CONDITIONS RELATED TO THE

WORK. ANY DISCREPANCIES BETWEEN THE DRAWINGS AND THE ACTUAL CONDITIONS SHALL BE

REPORTED TO THE DESIGN PROFESSIONALS FOR RESOLUTION PRIOR TO PROCEEDING WITH

THE WORK.

33. DRAWINGS CONTAINED IN THIS SET SHALL NOT BE REPRODUCED FOR SHOP DRAWINGS.

COPIES OF THESE DRAWINGS SUBMITTED AS SHOP DRAWINGS WILL BE REJECTED AND

RETURNED TO THE CONTRACTOR.

34. EACH INSTALLER MUST EXAMINE SUBSTRATE AND/OR CONDITIONS UNDER WHICH THE WORK

WILL BE INSTALLED AND REPORT TO THE CONTRACTOR IN WRITING ANY CONDITIONS

DETRIMENTAL TO THE PROPER AND TIMELY EXECUTION OF THE INSTALLER'S WORK. DO NOT

PROCEED UNTIL UNSATISFACTORY CONDITIONS ARE CORRECTED. INSTALLATION SHALL

CONSTITUTE ACCEPTANCE OF THE SUBSTRATE AND/OR CONDITIONS.

35. "TYPICAL" AS USED IN THESE DOCUMENTS SHALL MEAN THAT THE CONDITIONS OR DIMENSION

IS THE SAME OR REPRESENTATIVE FOR SIMILAR CONDITIONS THROUGHOUT.

REFLECTED CEILING PLAN GENERAL NOTES

1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND ABBREVIATIONS REFER TO

SHEET A-001 AND A-002. REFER TO A-102 FOR CEILING LEGEND.

2. ARCHITECTURAL CEILING PLANS INDICATE DIMENSIONING AND PLACEMENT OF VARIOUS

CEILING MOUNTED DEVICES. REFER TO MEP DRAWINGS AND SPECIFICATIONS FOR ALL

OTHER INFORMATION FOR MEP SYSTEMS INCLUDING BUT NOT LIMITED TO FIRE

SUPPRESSION, FIRE ALARM DEVICES, SECURITY DEVICES, EXIT DEVICES, DIFFUSERS,

LIGHTING, LIGHTING CONTROL DEVICES, AND ACCESS PANELS.

3. CEILING HEIGHTS ARE SHOWN TO HEIGHT ABOVE FINISH FLOOR. CEILING HEIGHT IS 10'-0"

A.F.F. UNLESS NOTED OTHERWISE.

4. ALL CEILING GRIDS TO BE CENTERED IN ROOMS UNLESS NOTED OTHERWISE.

5. ALL LIGHTS, SPEAKERS, SPRINKLERS, SIGNAGE, STROBES AND OTHER HARDWARE INSTALLED

IN TILED CEILING SYSTEMS TO BE CENTERED IN TILES IN BOTH DIRECTIONS UNLESS NOTED

OTHERWISE.

6. ALIGN ALL CEILING MOUNTED DEVICES.

7. REFERENCE ROOM FINISH SCHEDULE FOR ADDITIONAL CEILING FINISH INFORMATION.

8. CEILING MOUNTED EXIT SIGNS TO BE CENTERED WITHIN DOOR FRAME OR OPENING. MOUNT

4" OFF FACE OF WALL.

9. ALL SPRINKLERS, JUNCTION BOXES & SMOKE DETECTORS TO ALIGN WITH ADJACENT LIGHT

FIXTURES, UNLESS NOTED OTHERWISE.

10. COORDINATE LOCATIONS OF CEILING ACCESS PANELS WITH THE FINAL LOCATIONS OF

MECHANICAL EQUIPMENT AS REQUIRED TO SERVICE EQUIPMENT AND TO PROVIDE ACCESS

TO ALL ABOVE CEILING EQUIPMENT.

11. AT CONTINUOUS RUNS OF GYPSUM BOARD ASSEMBLIES, PROVIDE CONTROL JOINTS AT A

MAXIMUM OF (1) PER 30 FEET, NOT TO EXCEED INDIVIDUAL AREAS OF 2,500 SQUARE FEET.

12. IN ROOMS THAT HAVE OPERABLE WALL PARTITIONS, CEILING DIMENSIONS AND HEIGHTS

NOTED ON ONE SIDE OF THE ROOM ALSO APPLY TO THE OTHER SIDE OF THE ROOM, UNLESS

NOTED OTHERWISE.

13. MOISTURE RESISTANT GYPSUM BOARD SHALL BE USED IN SOFFITS AND CEILINGS OF

RESTROOMS, LOCKER ROOMS, SHOWERS AND OTHER WET AREAS.

PROVIDE BLOCKING FOR ALL TOILET ACCESSORIES AS NEEDED.

FFL

M

IR

R O

R

(4

M A

X

(7 4"

M

IN

(3

M A

X

M

IR

R O

R A

B O

V E

L A

V A

T O

R Y

M

IR

R O

R

F U

L L

L E

N G

T H

(1

F O

L D

IN

G

S H

O W

E R

S E

A T

M O

P A

N D

B R

O O

M H

O L

D E

R

R O

B E

H O

O K

R O

B E

H O

O K

(3

B A

B Y

C H

A N

G

IN

G S

T A

T

IO

N

FFL

P A

P E

R T

O W

E L

D

IS

P E

N S

E R

S O

A P

D

IS

P E

N S

E R

T O

IL

E

T S

E A

T C

O V

E R

D

IS

P E

N S

E R

S A

N

IT

A R

Y N

A P

K

IN

D

IS

P O

S A

L

T O

IL

E

T P

A P

E R

D

IS

P E

N S

E R

S A

N

IT

A R

Y N

A P

K

IN

D

IS

P E

N S

E R

P A

P E

R T

O W

E L

D

IS

P E

N S

E R

W

IT

H W

A S

T E

D

IS

P O

S A

L

E L

E C

T R

IC

H

A N

D D

R Y

E R

" 48

(3

(3

(3

M A

X

H E

IG

H

T M

O U

N T

IN

G

(A B

A

R

Q U

IR

D

R

N G

E

(3

(3

(3

(3

D R

IN

K

IN

G

F O

U N

T A

IN

F

IX

T U

R E

/E Q

U

IP

M E

N T

T Y

P E

ADA

COMPLIANT

INDICATOR

LEGEND

FINISH FLOOR

LEVEL (FFL)

/2

NOTE:

(1

A N

S I .1

S

IN

G

L E

R O

L L

(1

A N

S I .1

D

U

B L E

R O

L L

(1

A D

A /A

B A

APRON

FRONT VIEW

(DOUBLE)

FACE OF

ADJACENT WALL

SIDE VIEW

EDGE OF WALL

BEYOND

WIDTH OF ALCOVE

48" MIN

T O

S P

O U

T

M A

X

TO SPOUT

24" MIN CLR

O F

L E

A D

IN

G

E D

G E

T O

B O

T T

O M

CLR FLOOR SPACE

30" MIN

DEPTH OF

24" MAX

ALCOVE

T O

S P

O U

T

M A

X

9" M

IN

6" MIN

8" MIN

T O

B O

T T

O M

M

IN

F O

R C

LR

15" MIN.

5" MAX.

11" MIN

4" MAX

CONTROL

WALL

SEAT WALL

B A

C K

W

L

L

4" MAX

1' - 3"

M A

X

M A

X

CL

CONTROL WALL

ELEVATION

LOCATION OF

CONTROLS AND

HAND SHOWER

M A

X

1/

2"

MAX

1 1/2"

14"-15"

3" MAX

OF SEAT

PLAN VIEW SIDE VIEW

3' - 0" 30" MIN

3'

M

IN

6" M

A X

4" M

IN

M

IN

CLEAR

FLOOR

SPACE

48" MIN.

19" MAX.

M

IN

KNEE

CLEARANCE

8" MIN.

25" MAX.

17" MIN.

11" MIN.

M A

X

B .O

. M

IR

R O

R

M A

X

M

IN

9" M

IN

6" MAX.

H U

R L

B U

R T

F

IE

L D

F

L O

R

ID

A H

A N

G A

R

A M

U P

R O

J E

C T

N O

F

T E

V

M O

B

IL

E D

IS

T

R

IC

T M

O B

IL

E

A

L A

B A

M A

Mobile District

US Army Corps of

Engineers ®

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R N

O

U S

A R

M Y

C O

R P

S

G

IN

E E

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

FILE:

DATE:

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y

M O

B U

R N

S

M c D

O N

N E

L L

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S B

M T

B Y

P L

O T

S C

A L E

S

IZ

E x

F

IL

E N

A M

E

C K

D B

Y

P L

O T

D A

T E

D A

T E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

P R

O J E

C T

N U

M B

E R

C A

D D

C O

D E

J U

L Y

W

-2

-R

-0

F T

E V

M E

F

JU

L

Y

A

M A

S H

E K

7/6/2020 12:28:59 PM

A s in d ic a te d

T

K

IM

C

L A

U B

E R

T H

A

C O

H E

N

A-003-0004

A -0

-0

A-003

A B

A I N

F O

R M

A T

IO

N

NTSSCALE:B3

STANDARD ABA MOUNTING HEIGHTS

NTSSCALE:A1

ELECTRIC WATER COOLER

NTSSCALE:B1

SHOWER STALLS

NTSSCALE:A3

LAVATORIES

FLUSH VALVE SHALL BE LOCATED

ON WIDE SIDE OF STALLS

12" MIN

36" MIN

TOILET

PAPER

42" MIN

A

7.

M

IN

IC

C

/A N

S I

12" MAX

TRANSFER

SIDE

39" - 41"

M

IN

7"- 9"

24" MIN

M

IN

A D

A /A

B A

D O

U B

LE

R

O

LL

(1 8"

M

S

G

LE

R

O

LL

1/

2" C

LE

A

R M

IN

NOTE:

INTERNATIONAL PLUMBING

CODE (IPC) GOVERNS

42" MIN

M

IN

42" MIN

12" MAX

54" MIN

56" MIN WALL WC

60" IPC 2000

59" MIN FLOOR WC

(ICC / ANSI A117.1 & ABA / ADA)

3'

M

IN

4" M

A X

6" MIN*

4" MAX

32" MIN

6" M

IN

ALTERNATE DOOR

LOCATION

TOE CLEARANCE 9"

HIGH AFF CLR *

32" MIN

36" MIN

42" ICC / ANSI A117.1

GOVERNS - CLEAR FROM

OUTSIDE FACE OF

ADJACENT STALL

42" MIN

56" MIN WALL WC

60" IPC 2000

59" MIN FLOOR WC

(ICC / ANSI 117.1 & ABA / ADA)

M

IN

42" MIN

12" MAX

M

IN

54" MIN

1. WHERE "*" IS INDICATED - TOE CLEARANCE AT THE FRONT OF THE PARTITION IS NOT REQUIRED IN A COMPARTMENT GREATER THAN 62" DEEP WITH A WALL-HUNG WATER CLOSET OR 65" DEEP WITH A FLOOR-MOUNTED WATER CLOSET. TOE CLEARANCE AT THE SIDE IS NOT REQUIRED IN A COMPARTMENT GREATER THAN 66" WIDE (ICC / ANSI A117.1 / ABA / ADA). TOE CLEARANCE IS EXCLUSIVE OF PARTITION SUPPORT MEMBERS.

STANDARD STALL STANDARD STALL

LATCH SIDE APPROACH

ONLY, ALL OTHER

APPROACHES TO BE 48"

(ABA / ADA)

INTERNATIONAL

PLUMBING CODE

(IPC) GOVERNS

M

IN

M

IN

1'

M

IN

M

IN

1'

CLEAR

FLOOR

SPACE

60" MIN

42" MIN

M

IN

A B

A

A D

A

G O

V E

R N

S

M

IN

IC

C

A

N S

I A

II7

.1

16" - 18"

CLEAR FLOOR SPACE @ WATER

CLOSETS NOT IN STALLS

CLEAR

FLOOR

SPACE

36" IF IN ALCOVE

GREATER THAN 24" DEEP

30" TYP

T Y

P

TAPERED

ELONGATED RIM13 1/2" MIN

A B

A

A D

A

M A

X A B

A

A D

A

M A

X

FINISHED WALL.

4" MIN. 3' - 4" 1' - 0"

1' - 6" MIN.

VERIFY THERE IS A MINIMUM 18" CLEAR

FROM DOOR STRIKE TO INTERSECTING

WALL FOR ACCESSIBLE COMPLIANCE.

NOTIFY CONTRACT OFFICER FOR NON-

COMPLIANCE BEFORE SETTING DOOR

FRAME AND WALL LOCATIONS.

TYPICAL DOOR JAMB

LOCATION UNLESS

DIMENSIONED OTHERWISE.

ALL ROOM SIGNS, LIGHT

SWITCHES AND

THERMOSTATS TO BE

LOCATED WITHIN THIS SPACE.

REVIEW GUIDELINES FOR OTHER DOOR

APPROACH CLEARANCE REQUIREMENTS.

NOTE:

H U

R L

B U

R T

F

IE

L D

F

L O

R

ID

A H

A N

G A

R

A M

U P

R O

J E

C T

N O

F

T E

V

M O

B

IL

E D

IS

T

R

IC

T M

O B

IL

E

A

L A

B A

M A

Mobile District

US Army Corps of

Engineers ®

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R N

O

U S

A R

M Y

C O

R P

S

G

IN

E E

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

FILE:

DATE:

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y

M O

B U

R N

S

M c D

O N

N E

L L

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S B

M T

B Y

P L

O T

S C

A L E

S

IZ

E x

F

IL

E N

A M

E

C K

D B

Y

P L

O T

D A

T E

D A

T E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

P R

O J E

C T

N U

M B

E R

C A

D D

C O

D E

J U

L Y

W

-2

-R

-0

F T

E V

M E

F

JU

L

Y

A

M A

S H

E K

7/6/2020 12:29:01 PM

/2

'-0

T

K

IM

C

L A

U B

E R

T H

A

C O

H E

N

A-004-0004

A -0

-0

A-004

A B

A I N

F O

R M

A T

IO

N

NTSSCALE:A4

GRAB BARS

NTSSCALE:C2

STANDARD STALLS

NTSSCALE:C1

WATER CLOSETS

NTSSCALE:A2

URINALS

NTSSCALE:A1

DOOR CLEARNACES

A-202

C1

A-202

B1

B

E

F

J

K

L

M

N

P

D

5 6 7 8 9 10 11 12 13 14 16 17 19 20 21 22

8'

3'

2'

301E

307 306

301D

311 308

506A

507 508

226224

222 221

217A

230A231

203 202A

213A

213 212

212A

401A

402117

109 108

110111

103A

124126 125

MECHANICAL

YARD

504503

A1

A-301

A1

A-302

C1

A-301

B4

A-302

6' - 0"

10' - 0" 25' - 0" 10' - 0"

3' - 7"

51' - 4" 60' - 2" 45' - 10" 53' - 11" 14' - 3" 28' - 1" 20' - 7 1/2" 20' - 7 1/2" 20' - 7 1/2" 20' - 7 1/2" 20' - 7 1/2" 20' - 7 1/2" 20' - 7 1/2" 20' - 7 1/2" 28' - 1" 18' - 9" 34' - 1"

6' - 1"

10' - 0"

8'

51' - 4" 63' - 4" 42' - 8" 166' - 8" 50' - 8" 128' - 0"

4'

122' - 0"

6'

"41' - 4"

42' - 8"

51' - 4"

102' - 8"

224' - 8" 35' - 8" 154' - 8" 35' - 8" 52' - 0"

RAMP

DN

RAMP

DN

RAMP

DN

CRANE

COVERAGE

301C

301B

301A

6'

317 605

A-201

C1

A-201

C3

C3

A-203

B3

A-203

C1

A-203

B1

A-203

9' - 4"

1 2

C

G

H

606516

B1

A-302

B3 & C3 B1 & C1

47' - 6" 30

32' - 0"

N

H U

R L

B U

R T

F

IE

L D

F

L O

R

ID

A H

A N

G A

R

A M

U P

R O

J E

C T

N O

F

T E

V

M O

B

IL

E D

IS

T

R

IC

T M

O B

IL

E

A

L A

B A

M A

Mobile District

US Army Corps of

Engineers ®

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R N

O

U S

A R

M Y

C O

R P

S

G

IN

E E

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

FILE:

DATE:

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y

M O

B U

R N

S

M c D

O N

N E

L L

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S B

M T

B Y

P L

O T

S C

A L E

S

IZ

E x

F

IL

E N

A M

E

C K

D B

Y

P L

O T

D A

T E

D A

T E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

P R

O J E

C T

N U

M B

E R

C A

D D

C O

D E

J U

L Y

W

-2

-R

-0

F T

E V

M E

F

JU

L

Y

A B C

D E F

KEY PLAN

NOT TO SCALE

A

M A

S H

E K

7/6/2020 12:29:16 PM

/6

'-0

T

K

IM

C

L A

U B

E R

T H

A

C O

H E

N

A-101-0004

A -1

-0

A-101

O V

E R

A L L F

L O

O R

P L A

N

SCALE: 3/64" = 1'-0"B1

OVERALL FLOOR PLAN

0 16' 32' 48'

N

ROOM SCHEDULE

NUMBER ROOM NAME

503 SENIOR SUPERINTENDENT

504 ASST SEC CHIEF

505 ASST SEC CHIEF AND NCOIC

506 PRODUCTION TEAM ROOM

506A PRODUCTION SUPERINTENDENT

507 SPO

508 AFETS

510 LEAD PRODUCTION SUPERINTENDENT

511 FSR

512 PLANNING AND SCHEDULING

513 DEBRIEF / JOB CONTROL

514 CORRIDOR

515 COVERED TUG DOOR

516 CORRIDOR

601 SUPPLY ROOM

602 HAZARDOUS STORAGE

603 COVERED LAUNCH PIT

604 EXTERIOR COVERED STORAGE

605 CORRIDOR

606 CORRIDOR

ROOM SCHEDULE

NUMBER ROOM NAME

305 DASH21 EQUIPMENT STORAGE

306 WOMENS TOILET

307 MENS TOILET

308 COMM

310 JAN

311 FIRE PUMP / FOAM ROOM

312 ELEC

313 MECH

314 VEST

315 CORRIDOR

316 VEST

317 CORRIDOR

401 OPEN-FLOOR GUN MAINTENANCE

401A ARMAMENT EQUIPMENT STORAGE

402 CRANE SECURE WEAPONS STORAGE

403 SNC BAY

404 SNC EXTERIOR COVERED STORAGE

405 SNC EXTERIOR COVERED STORAGE

501 HANGAR BAY

502 CREW CHIEFS TEAM ROOM

ROOM SCHEDULE

NUMBER ROOM NAME

230 WEAPONS TEAM ROOM

230A WEAPONS PRODUCTION ROOM

231 SENIOR SUPERINTENDENT

232 NCOIC & ASST NCOIC

233 SEC CHIEF & ASST SEC CHIEF

234 WOMENS TOILET

235 JAN

236 MENS TOILET

237 MECH

238 VEST

240 CORRIDOR

241 VEST

301 CTK

301A OFFICE SUPPLY & MISC STORAGE

301B TOOL INSPECTION REPAIR AREA

301C EXPENDABLES SPARE/BROKEN TOOL AREA

301D EQUIPMENT MANAGER / SUPPORT / TODO

301E ENGINE STORAGE

302 SUPPORT NCOIC

303 PRIVATE SUPPORT NCOIC

304 LASER ETCHER ROOM

ROOM SCHEDULE

NUMBER ROOM NAME

211 AMU CONF

212 OIC

212A AMU SUPERINTENDENT

213 ASST OIC

213A ASST AMU SUPERINTENDENT

214 COPY

215 NURSING

216 AUDITORIUM

217 MULTI-PURPOSE

217A RECYCLE

218 SECURE COMM

220 MOBILITY SECTION & TRAINING MANAGERS

221 MENS TOILET

222 WOMENS TOILET

223 SPECIALISTS TEAM ROOM

224 ENGINES, ELECTRIC, & HYDRO NCOIC

225 SECURE CLASSIFIED STORAGE VAULT

226 COMNAV, INTEGRATED, AVIONICS, &

ELECTRONIC WAREFARE NCOIC

227 ASSISTANT SECTION CHIEFS

228 SENIOR SUPERINTENDENT

ROOM SCHEDULE

NUMBER ROOM NAME

121 ARMAMENT NCOIC

122 CRANE FIELD SERVICE LEAD

123 ARMAMENT FLIGHT CHIEF

124 STORAGE

125 ELEC

126 COMM

127 VEST

128 CORRIDOR

129 VEST

130 FIRE PROTECTION ROOM

131 STORAGE

201 CCS COMMANDER SUPPORT SECTION

202 COMMANDER SUITE

202A RECEPTION

203 COMMANDER OFFICE

204 CONF

205 SECTION COMMANDER

206 MAINTENANCE OFFICER

207 SUPERINTENDENT (CHIEF MASTER SERGEANT)

208 FIRST SERGEANT

210 FIRST SERGEANT

ROOM SCHEDULE

NUMBER ROOM NAME

101 SNC SUPPORT

102 BREAK

103 SNC LOGISTICS SUPPORT

103A LOGISTICS OFFICE

104 SNC LOGISTICS MANAGER

105 SNC CLS READY ROOM

106 SNC FIELD MANAGER

107 SNC FIELD MANAGER

108 SNC FIELD MANAGER

109 SNC AIRCRAFT MAINTENANCE MANAGER

110 SNC QUALITY ASSURANCE

111 SNC STORAGE

112 MENS TOILET

113 WOMENS TOILET

114 SHARED CONF

115 POTFF

116 LOGISTICS WAREHOUSE

117 ARMAMENT SUPPORT SECTION

118 SUPPORT SECTION NCOIC

120 COMMON OFFICE / READY ROOM / CRANE

OPEN OFFICE

E

F

J

K

L

M

N

P

D

5 6 7 8 9 10 11 12 13 14 16 17 19 20 21 22 2418

8'

3'

2'

10' - 0"

25' - 0"

10' - 0" 3' - 7"

51' - 4" 60' - 2" 45' - 10" 53' - 11" 14' - 3" 28' - 1" 20' - 7 1/2" 20' - 7 1/2" 20' - 7 1/2" 20' - 7 1/2" 20' - 7 1/2" 20' - 7 1/2" 20' - 7 1/2" 20' - 7 1/2" 28' - 1" 18' - 9" 34' - 1"

6' - 1" 10' - 0"

43 231 2 15

DRAFT CURTAIN

C

G

H

7 TON UNDER RUNNING

CRANE COVERAGE.

3 TON TOP RUNNING

CRANE COVERAGE.

2' x 2' ACOUSTICAL CEILING TILE

GYPSUM BOARD - PAINT

RECESSED CAN LIGHT

10' - 0"

CEILING HEIGHT ABOVE FINISH FLOOR

HVAC AIR SUPPLY GRILLE

HVAC EXHAUST OR RETURN GRILLE

CRANE COVERAGE

STRUCTURAL STEEL BEAM - PAINT

COVE LIGHT

EXPOSED CEILING

WALL MOUNTED EXTERIOR LIGHT FIXTURE

EXTERIOR FIXTURE

OTS

1' x 4' FLUORESCENT EMERGENCY FIXTURE - SUSPENDED

OPEN TO STRUCTURE- ALL EXPOSED ELEMENTS

INLCUDING MEP AND FP ELEMENTS SHALL BE PAINTED

METAL CEILING / SOFFIT (MP-3) 1' x 4' FLUORESCENT FIXTURE - SUSPENDED

2' x 4' FLUORESCENT EMERGENCY FIXTURE - RECESSED

2' x 4' FLUORESCENT FIXTURE - RECESSED

2' x 2' FLOURESCENT EMERGENCY FIXTURE - RECESSED

RECESSED EMERGENCY CAN LIGHT

CEILING LEGEND:

1.5" GA. 18 GALV. STEEL DECKING

STEEL GRATING

EXPOSED CONCRETE - PAINTED

LARGE DIAMETER, LOW SPEED INDUSTRIAL CEILING FAN

2' x 4' FLUORESCENT EMERGENCY FIXTURE - SUSPENDED

2' x 4' FLUORESCENT FIXTURE - SUSPENDED

FOAM GENERATOR

GA. 16 GALV. STEEL METAL

2' x 2' FLUORESCENT FIXTURE - RECESSED

N

H U

R L

B U

R T

F

IE

L D

F

L O

R

ID

A H

A N

G A

R

A M

U P

R O

J E

C T

N O

F

T E

V

M O

B

IL

E D

IS

T

R

IC

T M

O B

IL

E

A

L A

B A

M A

Mobile District

US Army Corps of

Engineers ®

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R N

O

U S

A R

M Y

C O

R P

S

G

IN

E E

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

FILE:

DATE:

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y

M O

B U

R N

S

M c D

O N

N E

L L

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S B

M T

B Y

P L

O T

S C

A L E

S

IZ

E x

F

IL

E N

A M

E

C K

D B

Y

P L

O T

D A

T E

D A

T E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

P R

O J E

C T

N U

M B

E R

C A

D D

C O

D E

J U

L Y

W

-2

-R

-0

F T

E V

M E

F

JU

L

Y

A B C

D E F

KEY PLAN

NOT TO SCALE

A

M A

S H

E K

7/6/2020 12:29:26 PM

A s in d ic a te d

T

K

IM

C

L A

U B

E R

T H

A

C O

H E

N

A-102-0004

A -1

-0

A-102

O V

E R

A L L R

E F

L E

C T

E D

C E

IL

IN

G P

L A

N

SCALE: 3/64" = 1'-0"A1

OVERALL REFLECTED CEILING PLAN

0 16' 32' 48'

E

F

J

K

L

M

N

P

D

5 6 7 8 9 10 11 12 13 14 16 17 19 20 21 22 24

10' - 0"

25' - 0"

10' - 0" 3' - 7"

51' - 4" 60' - 2" 45' - 10" 53' - 11" 14' - 3" 28' - 1" 20' - 7 1/2" 20' - 7 1/2" 20' - 7 1/2" 20' - 7 1/2" 20' - 7 1/2" 20' - 7 1/2" 20' - 7 1/2" 20' - 7 1/2" 28' - 1" 18' - 9" 34' - 1"

6' - 1" 10' - 0"

8'

2'

1843 23

1" / 12" 1" / 12"

1" / 12"

1" / 12"

3" / 12" 3" / 12"

FALL PROTECTION CABLE

FALL PROTECTION

CABLE FALL

PROTECTION

CABLE

FALL PROTECTION

CABLE

FALL

PROTECTION

CABLE

1 2

ROOF HIP

FLASHING

ROOF PEAK

FLASHING

ROOF PEAK

FLASHING

ROOF HATCH

ROOF HATCH

DS DS

DS DS DS DS

DS DS DS DS DS

DS DS DS

DS DS DS DS DS

DS DS

DS

DS

DS

DS

C

DS DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

ROOF HATCH &

GUARDRAIL

15' - 0"

" 15

15' - 0"

15' - 0"

15' - 0"

15' - 0"

15' - 0"

15' - 0"

15' - 0"

15' - 0"

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS DS

SEE NOTE 13

SEE NOTE 13

DS DSDS

DS

C3

A-572

C3

A-572

H

DS

DS

LOW ROOF

RE:

SIM

/A1 A-311

LOW ROOF

RE: /A1 A-311

DS

3' - 0"

SEE NOTE 13

C4

A-530

C1

A-530

HIGH

INTERM.

SSMR

SSMR

SSMR

SSMR

DS DS DS DS

EQ EQ

E Q

E Q

E Q

E Q

EQ EQ EQ EQ

ROOF ACCESS

LADDER

ROOF ACCESS

LADDER

ROOF ACCESS

LADDER

ROOF ACCESS

LADDER

FALL PROTECTION

CABLE

FALL PROTECTION

CABLE

C1

A-572

C1

A-573

DS

ROOF PLATFORM

GRATING

RE:

CANOPY

CANOPY

CANOPY

ROOF PLATFORM

GRATING

RE:

ROOF PLATFORM

GRATING

RE: /A3 A-571

/A3 A-571

ROOF PLATFORM

GRATING

RE: /A3 A-571

FLUE PENETRATION (TYP.

WHERE OCCURS)

RE: /A1 A-571

1" / 12"

1" / 12" 1" / 12"

8' - 6"

14' - 6"

8' - 6"

3' - 6"

LOW ROOF ACCESS LADDER

RE:

ROOF PLATFORM GRATING

RE: /A3 A-571

/A3 A-571

/C3 A-551

DS

FALL PROTECTION

CABLE

FALL PROTECTION

CABLE

DS

D3

A-571

GENERAL ROOF PLAN NOTES:

1.

2.

3.

4.

5.

6.

MINIMUM GUTTER SIZE SHALL BE: 10"(W) X 10"(H).

PROVIDE RECTANGULAR DOWNSPOUTS. MINUMUM DOWNSPOUT SHALL BE: 6"(L) X 8"(W).

PROVIDE HYDROSTATIC ROOF SYSTEM PER UFC 3-110-03, 5-3. ALL ROOFS SHALL HAVE FIXED POINT AT MIDSPAN OF ROOF PANEL. ALLOW THERMAL MOVEMENT AT PEAK (OR RIDGE) AND EAVE.

PROVIDE 1:12 ROOF SLOPE U.N.O.

DOWNSPOUTS ARE CONNECTED TO UNDERGROUND STORM WATER PIPES. REFERENCE CIVIL

DRAWINGS FOR DOWNSPOUT BOOT DETAILS.

DS: DOWNSPOUTS

GUTTER, GUTTER BRACKET, GUTTER STRAP, DOWNSPOUT, AND CONDUCTOR SHALL BE DESIGNED

TO MEET SMACNA - ARCHITECTURAL SHEET METAL MANUAL REQUIREMENTS.

7.

8.

9.

INSTALL FALL PROTECTION SAFETY CABLE 15'-0" OFFSET FROM ROOF EDGE. U.N.O.

SEE A-571 THROUGH A-572 FOR ROOF DETAILS.

ROOF CONSTRUCTION FROM TOP OF ROOF (HANGAR BAY):

+ STANDING SEAM METAL ROOF

+ AIR / VAPOR BARRIER

+ 5/8" EXTERIOR GYPSUM COVERBOARD

+ MINIMUM 2 LAYERS RIGID INSULATION (5" / R-25 MIN)

+ 1/2" GYPSUM THERMAL BARRIER

+ GALVANIZED STEEL DECKING.

10.

11.

12.

13.

ROOF CONSTRUCTION FROM TOP OF ROOF (ALL ROOF AREAS EXCEPT BAY AND EXTERIOR

STORAGE):

+ STANDING SEAM METAL ROOF

+ AIR / VAPOR BARRIER

+ 5/8" EXTERIOR GYPSUM COVERBOARD

+ MINIMUM 2 LAYERS RIGID INSULATION (6.7" / R-33 MIN)

+ 1/2" GYPSUM THERMAL BARRIER

+ GALVANIZED STEEL DECKING.

ROOF AIR/VAPOR BARRIER SHALL BE EXTENDED AND OVERLAP W/ WALL AIR/VAPOR BARRIER.

PROVIDE METAL SPLASH PAN WHERE STORM WATER IS DISCHARGED TO LOWER ROOF. WATER

SHALL SPREAD OUT TO MINIMUM 3 ROOF PANELS.

EXTEND DOWNSPOUT(S) WITH 30 DEGREE DOWN SLOPE. SECURE EXTENDED DOWNSPOUTS TO

STANDING SEAM.

N

H U

R L

B U

R T

F

IE

L D

F

L O

R

ID

A H

A N

G A

R

A M

U P

R O

J E

C T

N O

F

T E

V

M O

B

IL

E D

IS

T

R

IC

T M

O B

IL

E

A

L A

B A

M A

Mobile District

US Army Corps of

Engineers ®

M A

R K

D E

S C

R

I…

This is the start of the file's text. The full file is on GovTribe.