This document provides details for a federal contract solicitation to construct an aircraft maintenance hangar and weapons shop at Hurlburt Field, Florida. The solicitation seeks to award a contract for construction of a 105,041 square foot maintenance hangar with aircraft maintenance unit shops and a weapons shop, to include a reinforced concrete foundation and floor slab, steel structure, masonry walls and standing seam metal roof, HVAC, fire and mass notification systems. Supporting facilities such as utilities, pavements and site improvements are required, along with airfield pavement to provide hangar access. Special site conditions require excavation, fill and stabilization work along with demolition of seven existing buildings. The solicitation was issued by the Department of the Army Corps of Engineers Engineering District Mobile.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| AM05 DRAWINGS.pdf | ||
| AM05.pdf | ||
| AM04.pdf | ||
| AM04 DRAWINGS.pdf | ||
| AM03.pdf | ||
| Minutes-Pre-Bid site visit.pdf | ||
| Minutes-Pre-Bid demo site visit.pdf | ||
| AM03 DRAWINGS.pdf | ||
| AM02.pdf | ||
| APPENDIX F- As Builts of Demo Buildings- 1 of 3.zip | ZIP file | |
| APPENDIX F- As Builts of Demo Buildings- 2 of 3.zip | ZIP file | |
| APPENDIX F- As Builts of Demo Buildings- 3 of 3.zip | ZIP file | |
| AM01 Drawings.pdf | ||
| AM01.pdf | ||
| RTA DRAWINGS VOL 2.pdf | ||
| VOL2.PDF | ||
| VOL4.PDF | ||
| RTA DRAWINGS VOL 1.pdf | ||
| VOL6.PDF | ||
| VOL1.PDF | ||
| VOL5.PDF | ||
| EM 385-1-1.pdf | ||
| RTA DRAWINGS VOL 3.pdf |
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
THIS PROJECT IS ADVERTISED ON AN UNRESTRICTED BASIS
VOLUME 3 OF 6
SOLICITATION NO: W9127820R0104
CADD NO: MEF20004
SPECIFICATIONS
FOR
FTEV153009 SOF AMU
AND
WEAPONS HANGAR FACILITY
HURLBURT FIELD, FLORIDA
(OKALOOSA COUNTY)
“GOOD ENGINEERING RESULTS IN A BETTER ENVIRONMENT”
U.S. ARMY ENGINEER DISTRICT, MOBILE
109 St. Joseph St
Mobile, Alabama 36602
FTEV153009 SOF AMU AND WEAPONS HANGAR FACILITY W9127820R0104
HURLBURT FIELD, FLORIDA MEF20004
Table of Contents Page 1
TABLE OF CONTENTS
VOLUME 1 OF 6
CHECKLIST FOR PREPARATION OF OFFERS
BIDDING REQUIREMENTS
STANDARD FORM 1442 - SOLICITATION, OFFER, AND AWARD
BIDDING SCHEDULE
EXPLANATION OF BID ITEMS
STANDARD FORM 24 - BID BOND
STANDARD FORM 28 - AFFIDAVIT OF INDIVIDUAL SURETY
STANDARD FORM LLL - DISCLOSURE OF LOBBYING ACTIVITIES
SMALL BUSINESS SUBCONTRACTING PLAN TEMPLATE
00 11 00 PROPOSAL SUBMISSION REQUIREMENTS AND INSTRUCTIONS
00 12 00 EVALUATION CRITERIA AND BASIS OF AWARD
00 21 16 INSTRUCTIONS TO PROPOSERS
00 45 00 REPRESENTATIONS AND CERTIFICATIONS
00 70 00 CONDITIONS OF THE CONTRACT
SPECIFICATIONS
DIVISION 01 - GENERAL REQUIREMENTS
01 00 00 ADDITIONAL SPECIAL CONTRACT REQUIREMENTS
PROJECT SIGNS
DD FORM 1354
DD FORM 1354 CHECKLIST
WAGE RATES (BUILDING)
WAGE RATES (HEAVY)
01 00 01 GENERAL CONTRACT REQUIREMENTS
CESAM FORM 1151
01 32 01.00 10 PROJECT SCHEDULE
01 33 00 SUBMITTAL PROCEDURES
SUBMITTAL REGISTER
FORM 4025
01 33 29 SUSTAINABILITY REPORTING
AIR FORCE SUSTAINABILITY REQUIREMENTS SCORESHEET
GUIDING PRINCIPLES ASSESSMENT
01 35 26 GOVERNMENTAL SAFETY REQUIREMENTS
01 42 00 SOURCES FOR REFERENCE PUBLICATIONS
01 45 00.00 10 QUALITY CONTROL
01 45 00.15 10 RESIDENT MANAGEMENT SYSTEM CONTRACTOR MODE (RMS CM)
SAM FORM 696
01 45 35 SPECIAL INSPECTIONS
STATEMENT OF SPECIAL INSPECTIONS
SCHEDULE OF SPECIAL INSPECTIONS
01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS – HURLBURT STANDARD
01 74 19 CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT
01 78 23 OPERATION AND MAINTENANCE DATA
01 91 00.15 TOTAL BUILDING COMMISSIONING
DIVISION 02 - EXISTING CONDITIONS
02 41 00 DEMOLITION
02 61 13 EXCAVATION AND HANDLING OF CONTAMINATED MATERIAL
Table of Contents Page 2
DIVISION 02 - EXISTING CONDITIONS (CONTINUED)
02 81 00 TRANSPORTATION AND DISPOSAL OF HAZARDOUS MATERIALS
02 82 00 ASBESTOS REMEDIATION
02 83 00 LEAD REMEDIATION
02 84 16 HANDLING OF LIGHTING BALLASTS AND LAMPS CONTAINING PCBs
AND MERCURY
DIVISION 03 - CONCRETE
03 11 13.00 10 STRUCTURAL CAST-IN-PLACE CONCRETE FORMING
03 15 00.00 10 CONCRETE ACCESSORIES
03 20 00.00 10 CONCRETE REINFORCING
03 30 00.00 10 CAST-IN-PLACE CONCRETE
03 35 00.00 10 CONCRETE FINISHING
03 39 00.00 10 CONCRETE CURING
03 42 13.00 10 PLANT-PRECAST CONCRETE PRODUCTS FOR BELOW GRADE CONSTRUCTION
DIVISION 04 – MASONRY
04 20 00 UNIT MASONRY
VOLUME 2 OF 6
DIVISION 05 - METALS
05 05 23.16 STRUCTURAL WELDING
05 12 00 STRUCTURAL STEEL
05 21 00 STEEL JOIST FRAMING
05 30 00 STEEL DECKS
05 40 00 COLD-FORMED METAL FRAMING
05 50 13 MISCELLANEOUS METAL FABRICATIONS
05 51 33 METAL LADDERS
05 52 00 METAL RAILINGS
DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES
06 10 00 ROUGH CARPENTRY
06 41 16.00 10 PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS
06 61 16 SOLID SURFACING FABRICATIONS
DIVISION 07 - THERMAL AND MOISTURE PROTECTION
07 05 23 PRESSURE TESTING AN AIR BARRIER SYSTEM FOR AIR TIGHTNESS
07 11 13 BITUMINOUS DAMPPROOFING
07 21 13 BOARD AND BLOCK INSULATION
07 21 16 MINERAL FIBER BLANKET INSULATION
07 22 00 ROOF AND DECK INSULATION
07 27 10.00 10 BUILDING AIR BARRIER SYSTEM
07 27 19.01 SELF-ADHERING AIR BARRIERS
07 27 26 FLUID-APPLIED MEMBRANE AIR BARRIERS
07 27 36 SPRAY FOAM AIR BARRIERS
07 42 13 METAL WALL PANELS
07 42 63 FABRICATED WALL PANEL ASSEMBLIES
Table of Contents Page 3
DIVISION 07 - THERMAL AND MOISTURE PROTECTION (CONTINUED)
07 60 00 FLASHING AND SHEET METAL
07 61 14.00 20 STEEL STANDING SEAM ROOFING
07 84 00 FIRESTOPPING
07 92 00 JOINT SEALANTS
DIVISION 08 - OPENINGS
08 11 13 STEEL DOORS AND FRAMES
08 14 00 WOOD DOORS
08 31 00 ACCESS DOORS AND PANELS
08 33 13 COILING COUNTER DOORS
08 34 16.10 STEEL SLIDING HANGAR DOORS
08 34 19.10 20 ROLLING SERVICE DOORS
08 41 13 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS
08 51 13 ALUMINUM WINDOWS
08 51 23 STEEL WINDOWS
08 60 45 TRANSLUCENT PANELS
08 71 00 DOOR HARDWARE
08 81 00 GLAZING
08 91 00 METAL WALL LOUVERS
DIVISION 09 - FINISHES
09 06 00 SCHEDULES FOR FINISHES
09 22 00 SUPPORTS FOR PLASTER AND GYPSUM BOARD
09 29 00 GYPSUM BOARD
09 30 10 CERAMIC, QUARRY, AND GLASS TILING
09 51 00 ACOUSTICAL CEILINGS
09 65 00 RESILIENT FLOORING
09 67 23.15 FUEL RESISTIVE RESINOUS FLOORING, 3-COAT SYSTEM
09 67 23.16 FUEL RESISTIVE RESINOUS FLOORING, 5-COAT SYSTEM
09 68 00 CARPETING
09 90 00 PAINTS AND COATINGS
09 97 13.27 EXTERIOR COATING OF STEEL STRUCTURES
DIVISION 10 - SPECIALTIES
10 11 00 VISUAL DISPLAY UNITS
10 14 00.10 EXTERIOR SIGNAGE
10 14 00.20 INTERIOR SIGNAGE
10 21 13 TOILET COMPARTMENTS
10 22 13 WIRE MESH PARTITIONS
10 22 19 DEMOUNTABLE AND MOVABLE PARTITIONS
10 26 00 WALL AND DOOR PROTECTION
10 28 13 TOILET ACCESSORIES
10 51 13 METAL LOCKERS
DIVISION 11 - EQUIPMENT
11 01 50 FALL PROTECTION SYSTEMS
Table of Contents Page 4
VOLUME 3 OF 6
DIVISION 12 - FURNISHINGS
12 21 00 WINDOW BLINDS
12 48 13 ENTRANCE FLOOR MATS AND FRAMES
12 50 00.13 10 FURNITURE AND FURNITURE INSTALLATION
FFE ATTACHMENT
12 59 00 SYSTEMS FURNITURE
DIVISION 13 - SPECIAL CONSTRUCTION
13 48 00 BRACING FOR MISCELLANEOUS EQUIPMENT
DIVISION 21 - FIRE SUPPRESSION
21 13 13.00 10 WET PIPE SPRINKLER SYSTEM, FIRE PROTECTION
21 13 17.00 10 DRY PIPE SPRINKLER SYSTEM, FIRE PROTECTION
21 13 25.00 10 HIGH EXPANSION FOAM (HI EX HEF) FIRE PROTECTION SYSTEM
21 30 00 FIRE PUMPS
DIVISION 22 - PLUMBING
22 00 00 PLUMBING, GENERAL PURPOSE
DIVISION 23 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)
23 00 00 AIR SUPPLY, DISTRIBUTION, VENTILATION, AND EXHAUST SYSTEMS
23 05 48.19 BRACING FOR HVAC
23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC
23 07 00 THERMAL INSULATION FOR MECHANICAL SYSTEMS
23 09 00 INSTRUMENTATION AND CONTROL FOR HVAC
23 09 13 INSTRUMENTATION AND CONTROL DEVICES FOR HVAC
23 09 23.02 BACNET DIRECT DIGITAL CONTROL FOR HVAC AND OTHER BUILDING
CONTROL SYSTEMS
23 11 25 FACILITY GAS PIPING
23 54 16.00 10 HEATING SYSTEM; GAS-FIRED HEATERS
23 64 10 WATER CHILLERS, VAPOR COMPRESSION TYPE
23 64 26 CHILLED WATER PIPING SYSTEMS
23 81 00 DECENTRALIZED UNITARY HVAC EQUIPMENT
23 82 46.00 40 ELECTRIC UNIT HEATERS
DIVISION 25 - INTEGRATED AUTOMATION
25 05 11.01 CYBERSECURITY FOR FACILITY-RELATED CONTROL SYSTEMS ENERGY
MANAGEMENT CONTROL SYSTEM (EMCS) BUILDING LEVEL ONLY
25 05 11.02 CYBERSECURITY FOR FACILITY-RELATED CONTROL SYSTEMS FIRE
ALARM REPORTING SYSTEM/MASS NOTIFICATION SYSTEM BUILDING
LEVEL ONLY
25 10 10 UTILITY MONITORING AND CONTROL SYSTEM (UMCS) FRONT END AND
INTEGRATION
Table of Contents Page 5
VOLUME 4 OF 6
DIVISION 26 - ELECTRICAL
26 00 00.00 20 BASIC ELECTRICAL MATERIALS AND METHODS
26 12 19.10 THREE-PHASE PAD-MOUNTED TRANSFORMERS
26 20 00 INTERIOR DISTRIBUTION SYSTEM
26 24 13 SWITCHBOARDS
26 28 01.00 10 COORDINATED POWER SYSTEM PROTECTION
26 29 23 VARIABLE FREQUENCY DRIVE SYSTEMS UNDER 600 VOLTS
26 35 43 400-HERTZ (HZ) SOLID STATE FREQUENCY CONVERTER
26 41 00 LIGHTNING PROTECTION SYSTEM
26 42 14.00 10 CATHODIC PROTECTION SYSTEM (SACRIFICIAL ANODE)
26 51 00 INTERIOR LIGHTING
26 56 00 EXTERIOR LIGHTING
DIVISION 27 - COMMUNICATIONS
27 10 00 BUILDING TELECOMMUNICATIONS CABLING SYSTEM
27 51 16 PUBLIC ADDRESS SYSTEMS
DIVISION 28 - ELECTRONIC SAFETY AND SECURITY
28 31 76 INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM
DIVISION 31 - EARTHWORK
31 00 00 EARTHWORK
31 11 00 CLEARING AND GRUBBING
31 31 16.13 CHEMICAL TERMITE CONTROL
DIVISION 32 - EXTERIOR IMPROVEMENTS
32 01 16.71 COLD MILLING ASPHALT PAVING
32 01 19 FIELD MOLDED SEALANTS FOR SEALING JOINTS IN RIGID
PAVEMENTS
32 11 23 GRADED CRUSHED AGGREGATE AND AGGREGATE BASE COURSES
32 12 13 BITUMINOUS TACK AND PRIME COATS
32 12 15.13 ASPHALT PAVING FOR AIRFIELDS
32 12 16 HOT-MIX ASPHALT (HMA) FOR ROADS
32 13 13.06 PORTLAND CEMENT CONCRETE PAVEMENT FOR ROADS AND SITE
FACILITIES
32 13 14.13 CONCRETE PAVING FOR AIRFIELDS AND OTHER HEAVY DUTY PAVEMENTS
32 13 73 COMPRESSION JOINT SEALS FOR CONCRETE PAVEMENTS
32 16 19 CONCRETE CURBS, GUTTERS AND SIDEWALKS
32 17 23 PAVEMENT MARKINGS
32 31 13.53 HIGH-SECURITY CHAIN LINK FENCES AND GATES
32 92 23 SODDING
DIVISION 33 - UTILITIES
33 11 00 WATER UTILITY DISTRIBUTION PIPING
33 30 00 SANITARY SEWERAGE
33 32 16 PACKAGED UTILITY WASTEWATER PUMPING STATIONS
33 34 00 FORCE MAINS AND INVERTED SIPHONS; SEWER
33 40 00 STORM DRAINAGE UTILITIES
33 51 15 NATURAL-GAS / LIQUID PETROLEUM GAS DISTRIBUTION
Table of Contents Page 6
DIVISION 33 – UTILITIES (CONTINUED)
33 71 02 UNDERGROUND ELECTRICAL DISTRIBUTION
33 82 00 TELECOMMUNICATIONS OUTSIDE PLANT (OSP)
DIVISION 34 – TRANSPORTATION
34 73 13 MOORING AND GROUNDING POINTS FOR AIRCRAFT
DIVISION 41 – MATERIAL PROCESSING AND HANDLING EQUIPMENT
41 22 13.14 BRIDGE CRANES, OVERHEAD ELECTRIC, TOP RUNNING
41 22 13.15 BRIDGE CRANES, OVERHEAD ELECTRIC, UNDER RUNNING
VOLUME 5 OF 6
APPENDICES
APPENDIX A DRAFT SWPPP
APPENDIX B HAZARDOUS MATERIALS REPORTS
APPENDIX C EGLIN BORROW PIT GEOTECHNICAL DATA
VOLUME 6 OF 6
APPENDICES (CONTINUED)
APPENDIX D HAZARDOUS WASTE MANAGEMENT PLAN
APPENDIX E CAPA ERP
APPENDIX F AS-BUILTS OF DEMO BUILDINGS (PROVIDED ELECTRONICALLY ONLY)
APPENDIX G GEOTECHNICAL BORING LOGS
APPENDIX H HURLBURT ACM REPORT
APPENIDX I HURLBURT FIELD LEAD XRF AND CHIP SAMPLE REPORT
--End of Project Table of Contents--
SECTION 12 21 00
WINDOW BLINDS
08/17
PART 1 GENERAL
1.1 SUMMARY
Provide window treatment, conforming to NFPA 701 , complete with necessary brackets, fittings, and hardware. Provide each window treatment type as a complete unit in accordance with Paragraph "Window Treatment Placement Schedule". Mount and operate equipment in accordance with manufacturer's instructions. Completely cover windows to receive a treatment.
1.2 REFERENCES
The publications listed below form a part of this Specification to the extent referenced. The publications are referred to in the text by basic designation only.
CALIFORNIA DEPARTMENT OF PUBLIC HEALTH (CDPH)
CDPH SECTION 01350 (2010; Version 1.1) Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources using Environmental Chambers
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 701 (2019) Standard Methods of Fire Tests for Flame Propagation of Textiles and Films
SCIENTIFIC CERTIFICATION SYSTEMS (SCS)
SCS SCS Global Services (SCS) Indoor Advantage
UNDERWRITERS LABORATORIES (UL)
UL 2818 (2013) GREENGUARD Certification Program For Chemical Emissions For Building Materials, Finishes And Furnishings
1.3 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Installation
SECTION 12 21 00 Page 1
SD-03 Product Data
Window Blinds; G
Recycled Content for Aluminum Components; S
SD-04 Samples
Window Blinds; G, AE
SD-06 Test Reports
Window Blinds
SD-07 Certificates
Indoor Air Quality for Window Blinds; S
SD-08 Manufacturer's Instructions
Window Blinds; G
SD-10 Operation and Maintenance Data
Window Blinds; G
1.4 CERTIFICATIONS
1.4.1 Window Blinds
Provide products certified to meet indoor air quality requirements by UL 2818 Greenguard Gold, SCS Global Services Indoor Advantage Gold, or provide certification or validation by other third-party program that products meet the requirements of this Section. Provide current product certification documentation from certification body. When product does not have certification, provide validation that product meets the indoor air quality product requirements cited herein.
1.5 DELIVERY, STORAGE, AND HANDLING
Deliver components to the Job Site in the manufacturer's original packaging with the brand or company name, item identification, and Project reference clearly marked. Store components in a dry location that is adequately ventilated and free from dust, water, or other contaminants and has easy access for inspection and handling. Store materials flat in a clean dry area with temperature maintained above 50 degrees F. Do not open containers until needed for installation unless verification inspection is required.
1.6 WARRANTY
Provide manufacturer's standard performance guarantees or warranties that extend beyond a 1 year period.
PART 2 PRODUCTS
2.1 WINDOW BLINDS
Provide each blind, including hardware, accessory items, mounting brackets
SECTION 12 21 00 Page 2 and fastenings, as a complete unit produced by one manufacturer. Unless otherwise indicated, all parts will be the same color and will match the color of the blind slat. Treat steel features for corrosion resistance.
Submit product data and samples of each type and color of window treatment. Provide slat samples 6 inches in length for each color.
Window blinds must meet emissions requirements of CDPH SECTION 01350 (use the office or classroom requirement, regardless of space type). Provide certification or validation of indoor air quality for window blinds.
Provide Aluminum Components with a minimum of 24 percent recycled content. Provide data identifying percentage of recycled content for aluminum components.
Provide certification of indoor air quality for window blinds.
2.1.1 Horizontal Blinds
Provide horizontal blinds with 1 inch slats. Blind units must be capable of nominally 180 degree partial tilting operation and full-height raising. Blinds must be inside mount. Provide tapes for 2 inch slats with longitudinal reinforced vinyl plastic in 1-piece turn ladder construction. Tapes for 1 inch slats must be braided polyester or nylon.
2.1.1.1 Head Channel and Slats
Provide head channel made of aluminum with corrosion-resistant finish nominal 0.024 inch for 1 inch slats. Provide slats of aluminum, not less than 0.032 inch thick, and of sufficient strength to prevent sag or bow in the finished blind. Provide a sufficient amount of slats to assure proper control, uniform spacing, and adequate overlap. Enclose all hardware in the headrail.
2.1.1.2 Controls
A transparent tilting wand will be provided to tilt the slats, it will hang vertically by its own weight, and will swivel for easy operation.
Provide a tilter control of enclosed construction. Provide moving parts and mechanical drive made of compatible materials which do not require lubrication during normal expected life. The tilter will tilt the slats to any desired angle and hold them at that angle so that any vibration or movement of ladders and slats will not drive the tilter and change the angle of slats. Include a mechanism to prevent over tightening. Provide a wand of sufficient length to reach to within 5 feet of the floor.
2.1.1.3 Intermediate Brackets
Provide intermediate brackets for installation, as recommended by the manufacturer, of blinds over 60 inches wide.
2.1.1.4 Bottom Rail
Provide bottom rail made of corrosion-resistant steel with factory applied finish. Provide closed oval shaped bottom rail with double-lock seam for maximum strength. Bottom rail and end caps to match slats in color.
2.1.1.5 Braided Ladders
Provide braided ladders of 100 percent polyester yarn, color to match the slat color. Space ladders 15.2 slats per foot of drop in order to provide
SECTION 12 21 00 Page 3 a uniform overlap of the slats in a closed position.
2.2 COLOR
Provide color, pattern, and texture in accordance with Section 09 06 00 SCHEDULES FOR FINISHES. Color listed is not intended to limit the selection of equal colors from other manufacturers.
PART 3 EXECUTION
3.1 EXAMINATION
After becoming familiar with details of the Work, verify all dimensions in the field, and advise the Contracting Officer of any discrepancy before performing the Work.
3.2 WINDOW TREATMENT PLACEMENT SCHEDULE
All exterior windows include W01.
3.3 INSTALLATION
Do not install building construction materials that show visual evidence of biological growth.
Submit drawings showing fabrication and installation details. Show layout and locations of track, direction of draw, mounting heights, and details.
Provide Manufacturer's Instructions and Operation and Maintenance Data.
Perform installation of window blinds in accordance with the approved Detail Drawings and manufacturer's installation instructions. Install units level, plumb, secure, and at proper height and location relative to window units. Provide and install supplementary or miscellaneous items in total, including clips, brackets, or anchorages incidental to or necessary for a sound, secure, and complete installation. Do not start installation until completion of room painting and finishing operations.
3.4 CLEAN-UP
Upon completion of the installation, inspect window treatments for soiling, damage or blemishes; and adjust them for form and appearance and proper operating condition. Repair or replace damaged units as directed by the Contracting Officer. Isolate metal parts from direct contact with concrete, mortar, or dissimilar metals. Ensure blinds installed in recessed pockets can be removable without disturbing the pocket. The entire blind, when retracted, must be contained behind the pocket. For blinds installed outside the jambs and mullions, overlap each jamb and mullion 0.75 inch or more when the jamb and mullion sizes permit. Include all hardware, brackets, anchors, fasteners, and accessories necessary for a complete, finished installation.
-- End of Section --
SECTION 12 21 00 Page 4
SECTION 12 48 13
ENTRANCE FLOOR MATS AND FRAMES
08/17
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this Specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM B221 (2014) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes
ASTM D2047 (2017) Standard Test Method for Static Coefficient of Friction of Polish-Coated Floor Surfaces as Measured by the James Machine
ASTM E648 (2017a) Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines
1.2 SUSTAINABILITY REPORTING
Materials in this Technical Specification may increase Contract Compliance with sustainability requirements.
1.2.1 EPA Comprehensive Procurement Guidelines
See Section 01 33 29 SUSTAINABILITY REPORTING for requirements associated with EPA-designated products.
1.2.2 USDA Biobased
See Section 01 33 29 SUSTAINABILITY REPORTING for requirements associated with USDA Biobased products.
1.3 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in
SECTION 12 48 13 Page 1 accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Installation Drawings; G AE
Detail Drawings; G AE
SD-03 Product Data
Entrance Floor Mats and Frames; G AE
Adhesives and Concrete Primers; G AE S
SD-04 Samples
Entrance Floor Mats and Frames; G AE
SD-08 Manufacturer's Instructions
Manufacturer's Instructions
SD-10 Operation and Maintenance Data
Protection, Maintenance, and Repair Information
1.4 QUALITY CONTROL
Comply with 36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines for installed entrance floor mats and frames. Ensure that entrance floor mats and frames are slip-resistant in accordance with ASTM D2047, with a minimum 0.60 coefficient of friction, for accessible routes and are structurally capable of withstanding a uniform floor load of 300 pounds/square foot.
Ensure that flammability is in accordance with ASTM E648, Class 1, Critical Radiant Flux, minimum 0.45 watts/square meter.
1.5 DELIVERY, STORAGE, AND HANDLING
Deliver materials to the Project Site in their original packages or containers bearing labels clearly identifying the manufacturer, brand name, and quality or grade.
Store materials in their original unbroken packages or containers in the area in which they will be installed. Unwrap, inspect, and place mats at indicated locations. Remove all excess packing materials.
PART 2 PRODUCTS
2.1 MANUFACTURED UNITS
2.1.1 Entrance Floor Mats and Frames
Submit the manufacturer's catalog data. Submit samples of assembled sections of floor mats showing corners, intersections, and other details of construction. Submit samples of custom graphics, exposed floor mats, frame finishes and accessories.
SECTION 12 48 13 Page 2
2.1.1.1 Roll-Up Mats
Provide roll-up mats with mill finish aluminum tread rails spaced a maximum 2 inches on center and running counter to the traffic flow. Ensure that the mats must allow debris to fall to subfloor. Ensure that tread rails are connected by aluminum or vinyl hinges and include an aluminum edge around the perimeter and a continuous vinyl cushion.
Provide recessed mats mounted with carpet/bristle filament mix inserts.
2.1.1.2 Frames
Provide recessed frames in extruded aluminum alloy 6061-T6 or alloy 6063-T5 ASTM B221. Ensure that the frame depth accommodates the mat and system specified. Frame color is mill finish. Ensure that edge-frame members are fabricated in single lengths or with the fewest pieces possible, with hairline joints equally spaced and pieces spliced together by straight connecting pins. Ensure that any concealed surfaces of aluminum frames that contact cementitious material are coated with the manufacturer's standard protective coating. Ensure that frames include accessories and devices required for a complete installation.
2.1.2 Adhesives and Concrete Primers
Provide adhesives and concrete primers, where required, according to the manufacturer's recommendations.
Provide low-emitting materials in accordance with Section 01 33 29
SUSTAINABILITY REPORTING.
2.1.3 Color and Size
Ensure that color is in accordance with Section 09 06 00 SCHEDULES FOR FINISHES. Ensure that the size of mat is as indicated.
PART 3 EXECUTION
3.1 EXAMINATION
Comply with the manufacturer's requirements for substrates and floor conditions affecting installation of floor mats and frames. Ensure that all unsatisfactory conditions have been corrected before installation.
3.2 INSTALLATION
Submit Detail Drawings, and Custom Graphics Drawings as required. Provide Installation Drawings. Provide the manufacturer's protection, maintenance, and repair information.
Install floor mats and frames according to manufacturer's instructions.
Set mat tops at the height recommended by the manufacturer for the most effective cleaning action. Provide clearance between bottoms of doors and tops of mats. Coordinate recess frame installation with concrete construction to ensure that frame anchorage is correct and that the base is level and flat. Install grout and fill around frames and, if required to set mat tops at proper elevations, in recesses under mats. Finish grout and fill smooth and level.
SECTION 12 48 13 Page 3
SECTION 12 48 13 Page 4
SECTION 12 50 00.13 10
FURNITURE AND FURNITURE INSTALLATION
08/17
PART 1 GENERAL
Purchase and install furniture as identified within this Specification.
This Specification Section includes a Furniture, Fixtures and Equipment (FF&E) Package attachment.
The requirements of this Specification also apply to systems furniture unless otherwise specified in Section 12 59 00 Systems Furniture.
1.1 REFERENCES
The publications listed below form a part of this Specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING
ENGINEERS (ASHRAE)
ASHRAE 90.1 - IP (2013) Energy Standard for Buildings Except Low-Rise Residential Buildings
ASTM INTERNATIONAL (ASTM)
ASTM D4157 (2013; R 2017) Standard Test Method for Abrasion Resistance of Textile Fabrics (Oscillatory Cylinder Method)
ASTM E84 (2018a) Standard Test Method for Surface Burning Characteristics of Building Materials
BIFMA INTERNATIONAL (BIFMA)
ANSI/BIFMA X5.1 (2017) American National Standards For Office Furnishings - General Purpose Office Chairs
ANSI/BIFMA X5.3 (2007; R2012) American National Standards For Office Furnishings - Vertical Files
ANSI/BIFMA X5.4 (2012) American National Standards For Office Furnishings - Lounge Seating
ANSI/BIFMA X5.5 (2014) American National Standards For Office Furnishings -Desk Products
ANSI/BIFMA X5.6 (2016) American National Standards For Office Furnishings -Panel Systems
ANSI/BIFMA X5.9 (2012) American National Standards For Office Furnishings - Storage Units
SECTION 12 50 00.13 10 Page 1
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 101 (2018; TIA 18-1; TIA 18-2; TIA 18-3) Life Safety Code
NFPA 260 (2013) Standard Methods of Tests and Classification System for Cigarette Ignition Resistance of Components of Upholstered Furniture
NFPA 265 (2015) Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile Coverings on Full Height Panels and Walls
STATE OF CALIFORNIA DEPARTMENT OF CONSUMER AFFAIRS, BUREAU OF
ELECTRICAL AND APPLIANCE REPAIR, HOME FURNISHINGS AND THERMAL
INSULATION (BEARHFTI)
TB 117-2013 (2013) Requirements, Test Procedure and Apparatus for Testing the Smolder Resistance of Materials Used in Upholstered Furniture
TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA)
TIA-568-C.2 (2009; Errata 2010; Add 2 2014; Add 1 2016) Balanced Twisted-Pair Telecommunications Cabling and Components Standards
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines
UNDERWRITERS LABORATORIES (UL)
UL 723 (2018) UL Standard for Safety Test for Surface Burning Characteristics of Building Materials
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-01 Preconstruction Submittals
Storage Location; G
SD-02 Shop Drawings
SECTION 12 50 00.13 10 Page 2
Installation Drawings; G
Grommet and Wire Management; G
SD-03 Product Data
Product Data; G, AE
Product Style Options; G, AE
Energy Efficient Equipment; S
Reduced VOCs for Furniture; S
Recycled Content of Furniture; S
Bio-Based Content of Furniture; S
SD-04 Samples
Fabric and Finishes; G, AE
SD-07 Certificates
Authorized Dealer; G
Certified Furniture Installers; G
Licensed Electrician; G
Certified Telecommunications Installer; G
Manufacturer's Certification; G
Warranty; G
SD-10 Operation and Maintenance Data
Furniture, Data Package 1; G
1.3 SERVICES
Provide services to include furniture purchase, field measuring, Installation Drawings, shipping and delivery coordination, receiving, inspection, submitting and processing freight and warranty claims, unpacking, storing, assembly, installation and other related activities or tasks for a complete and functional installation. Reference Section 01 45 00.00 10 QUALITY CONTROL for inspection requirements. The Contracting Officer must be allowed to participate in inspections. In addition provide services for existing furniture as specified, reference Paragraph on "Existing Furniture" for more information. Develop Project timelines and establish shipping, receiving and installation dates that coordinate with the Building Construction Schedule. Hold at a minimum weekly team meetings to brief the Project Team, include the Contracting Officer. Notify the Contracting Officer immediately of any scheduling problems, discontinued furniture items including fabrics and finishes, or other conditions which may cause delays, and recommend available substitutes, solutions, and provide updated timeline to coordinate with
SECTION 12 50 00.13 10 Page 3
Building Construction Schedule. Substitutes and solutions must comply with the Specification and be approved by the Contracting Officer.
1.4 FURNITURE PURCHASE
Purchase furniture, including checking accuracy of all acknowledgements and schedules from manufacturers and making necessary corrections to insure that the manufacturer has a correct understanding of the order and requirement. Purchase furniture from the open market. The furniture provided needs to be available on the GSA Schedules to assist the User with future purchases. GSA information is provided FOR INFORMATIONAL PURPOSES ONLY. It is encouraged to solicit and provide GSA pricing on furniture. Compete the furniture purchase by obtaining a minimum of (3) separate proposals. Furniture is subject to FAR Clause 52.236-5 "Materials and Workmanship". If necessary to meet Project timeline requirements, furniture may be purchased using manufacturers quick-ship programs or by coordinating factory times.
1.5 ALTERNATE DESIGN
When a manufacturer's product is unable to provide desk and workstation configurations and filing/storage that conform exactly to the furniture layouts shown in the Contract Drawings and Specifications, alternate designs may be submitted for consideration by the Contracting Officer.
Alternate designs must meet or exceed the following criteria. Alternate designs that are submitted but do not meet these criteria will be rejected.
1.5.1 Desk and Workstation Size and Configuration
The alternate design must provide desks and workstations of the same basic size and configuration shown, with only the sizes of the individual components within the desk and workstation changed to meet the standard product of the manufacturer.
1.5.2 Filing and Storage Size and Configuration
The alternate design must provide filing and storage of the same basic size and configuration shown, with only the size changed to meet the standard product of the manufacturer. The storage capacity must not be reduced.
1.5.3 Furniture Requirements
The furniture provided must comply with the Drawings, Specifications, and the requirements identified in the FF&E Package Attachment.
1.5.4 Layout
The storage capacity, number of desks and workstations, number of persons accommodated, width of aisles, and functionality must be maintained.
Layout must comply with NFPA 101 and 36 CFR 1191 .
1.6 AUTHORIZED DEALER, CERTIFIED FURNITURE INSTALLERS, LICENSED ELECTRICIAN
AND CERTIFIED TELECOMMUNICATIONS INSTALLER
When required by the furniture manufacturer, furniture must be installed by an authorized dealer and a certified furniture installation crew must be used on the Project. All furniture requiring hardwiring must be completed by a licensed electrician. Communications installers must be
SECTION 12 50 00.13 10 Page 4
Building Industry Consulting Services International (BICSI) Registered Cabling Installers, Technician Level or have a minimum of 3 years experience in the installation of the specified cables and components.
All installers, furniture, electrical and communications, must be on-site if questions arise. Submit copies of authorized dealer, furniture installation crew, licensed electrician, and certified telecommunications installer certifications.
1.7 DELIVERY, STORAGE AND HANDLING
1.7.1 Delivery
Deliver furniture to the Job Site in manufacturer's original packaging or blanket wrapping. Original packaging must be marked with the manufacturer name, item identification, and Project reference clearly marked.
1.7.2 Furniture Inspection
Inspect furniture and provide notification of damage within the time frame required by the shipping company while carrier is still on-site. Complete claims for concealed damage within the time frame required by the shipping company and furniture manufacturer. A claim file must be maintained that documents each claim. Forward copies of claims to the Contracting Officer on a daily basis.
1.7.3 Storage
Storage space is not available on-site and furniture must be stored at an off-site location. Provide any storage space required for furniture and transport stored furniture to the Project Site for installation. Storage location must be approved by the Contracting Officer at the time of the furniture order. If storage is required, furniture must be stored in a dry location that is adequately ventilated and free from dirt and dust, water, and other contaminants, in a manner that permits easy access for inspection and handling, and in an environment in accordance with furniture manufacturers instructions.
1.7.4 Furniture Staging Area
Coordinate location of the furniture staging area with the Contracting Officer.
1.8 WARRANTY
Provide manufacturer performance guarantees or warranties for single-shift service and include parts, labor and transportation as follows, unless otherwise noted:
a. Systems Furniture - see Section 12 59 00 SYSTEMS FURNITURE.
b. Desks and Workstations - 12 year minimum.
c. Filing and Storage - 12 year minimum.
d. Seating:
(1) Seating, unless otherwise noted - 10 year minimum.
(2) 24/7 Seating (multiple shift use) - 10 year minimum.
SECTION 12 50 00.13 10 Page 5
(3) Seating Mechanisms and Pneumatic Cylinders - 10 year minimum.
(4) Lounge Seating - 10 year minimum.
(5) Stacking Chairs - 10 year minimum.
e. Tables:
(1) Unless otherwise noted - 10 year minimum.
(2) Table Mechanisms - 5 year minimum.
(3) Table Ganging Device - 1 year minimum.
f. Miscellaneous:
(1) Fabric - 3 year minimum.
(2) LED Task Lighting - 5 year minimum.
(3) Task Lighting - 3 year minimum.
Provide items not listed with a 1 year minimum. When manufacturers standard performance guarantees or warranties exceed the minimum requirements identified, provide the standard performance guarantee or warranty. Submit manufacturer's warranty information for all furniture items.
PART 2 PRODUCTS
2.1 PRODUCT SUSTAINABILITY CRITERIA
For products in this Section, where applicable and to extent allowed by performance criteria, provide and document the following:
2.1.1 Energy Efficient Equipment
Coordinate requirement for energy efficient equipment, such as appliances and lighting, and provide documentation in accordance with Section 01 33 29 SUSTAINABILITY REPORTING Paragraph "Energy Efficient Equipment".
2.1.2 Reduced VOC's for Furniture
Coordinate requirement for reduced VOC requirements for furniture and provide documentation in accordance with Section 01 33 29 SUSTAINABILITY REPORTING Paragraph "Reduce Volatile Organic Compounds".
2.1.3 Recycled Content of Furniture
Coordinate requirement for recycled content for furniture and provide documentation in accordance with Section 01 33 29 SUSTAINABILITY REPORTING Paragraph "Recycled Content".
2.1.4 Bio-Based Content of Furniture
Coordinate requirement for bio-based content for furniture and provide documentation in accordance with Section 01 33 29 SUSTAINABILITY REPORTING Paragraph "Bio-Based Products".
SECTION 12 50 00.13 10 Page 6
2.2 REFERENCE TO MANUFACTURER NAMES AND COLORS
Where product and color is shown as being specific to one manufacturer in the FF&E Package Attachment, an equivalent color or product by another manufacturer may be submitted for approval. Manufacturers, style lines, model numbers, finish, and fabric information are provided to establish design intent and are not intended to limit the selection of equal products and colors from other manufacturers.
2.3 FURNITURE REQUIREMENTS
Use the FF&E Package Attachment in conjunction with the Drawings and Specifications for the furniture requirements. Systems furniture is specified in Section 12 59 00 SYSTEMS FURNITURE. Provide furniture from manufacturer's standard product as shown in the most current published price list or amendment. Furniture provided must be part of current line as indicated with no intent to discontinue within two years. Provide furniture that is intended for commercial use not residential. Submit product data for all furniture items, to include catalog cuts, brochures, product information, and other necessary literature to indicate compliance with Specifications. Provide product data for all items together in a single submittal. Submit each grouping of similar type items in a single submittal. When applicable, include GSA schedule information to confirm that items are available on GSA schedule. Tag product data sheets with applicable furniture item code and name. Submit data for all product style options for selection when options are available. This applies to but is not limited to furniture items that have options such as edge details, hardware options, and grommet colors. Submit manufacturer's certification stating that furniture meets the Specifications.
2.3.1 Construction
a. Provide furniture that complies with the following testing requirements:
(1) ANSI/BIFMA:
(a) Office Seating - ANSI/BIFMA X5.1 .
(b) Vertical Files - ANSI/BIFMA X5.3 .
(c) Lounge Seating - ANSI/BIFMA X5.4 .
(d) Desk Products - ANSI/BIFMA X5.5 .
(e) Panel Systems - ANSI/BIFMA X5.6 .
(f) Storage - ANSI/BIFMA X5.9 .
(2) Flammability:
(a) Systems furniture and workstation panel components must meet requirements for flame spread and smoke development as specified by NFPA 101 except as follows. Conduct testing in accordance with either ASTM E84 or UL 723 on the entire assembled panel of the worst case (most combustible) combination of fabric and interior construction. In addition, fabric must meet the requirements of NFPA 265 . Panel flame spread shall not exceed 25 for Class A, and
SECTION 12 50 00.13 10 Page 7 panel smoke development shall not exceed 450 for Class A, B, and C.
(b) Upholstered furniture must comply with TB 117-2013 or NFPA 260 .
b. Provide furniture with no rough or sharp edges or exposed connections. Clips, screws, and other construction elements must be concealed wherever possible.
c. Items such as desks, workstations and systems furniture must include all necessary components to be structurally sound and must not be attached to the wall unless specified to be wall mounted in the Contract Documents.
d. Desks, workstations, storage, and tables must have leveling devices to compensate for uneven floors.
e. The underside of desks, workstations, and tables must be completely and smoothly finished.
f. The backside of freestanding desks, workstations, and storage must be finished.
g. Provide chair casters and glides appropriate for the floor material they are located on, such as carpet and resilient flooring.
2.3.2 Locks and Keying
a. All drawers and doors, including but not limited to overhead storage cabinets, storage towers, supply cabinets, storage cabinets, desk and workstation pedestals, and filing cabinets must be lockable.
b. Key each desk and workstation in an office differently and key locks within each desk and workstation alike.
c. Furniture storage components in private offices must be keyed alike.
Key each private office differently.
d. Provide field changeable lock cylinders in desks and workstations with a minimum of 100 different key options. Number keys and lock cylinders for ease of replacement or clearly label locks with a key number, except for those manufacturers who have removable format locks.
e. Drawers within a pedestal must be lockable either by a central lock that controls all pedestals under one work surface or an individual keyed lock in each pedestal.
f. Central file and storage units which are grouped together but are not a part of a workstation must be keyed differently unless otherwise specified.
g. Provide two keys for each workstation when components are keyed alike. Also provide two keys for each miscellaneous item such as filing cabinets, supply cabinets, storage cabinets, and similar type furniture items.
h. Provide three copies of each master key to the Contracting Officer.
i. Leave keys in locks.
SECTION 12 50 00.13 10 Page 8
2.3.3 Receptacle Bodies and Device Cover Plates
Provide furniture panel faceplates and receptacle body types and color as specified in 12 59 00 SYSTEMS FURNITURE. Provide color as follows:
a. Faceplate: Match panel trim color.
b. Receptacle Bodies: Match panel trim color.
c. Communication Cable Jackets: Match receptacle device cover plates in color.
d. Isolated Ground Receptacles: Orange or have distinct markings.
2.3.4 Keyboard Tray
Provide work surfaces that are capable of accepting an articulating keyboard tray at locations indicated. The keyboard tray must be capable of fully recessing under the work surface and extending to give the user full access to the keyboard. The keyboard tray must have height adjustability and positive and negative tilting capability and have 180-degree swing side travel rotation. The keyboard tray must have a wrist support and include a mouse pad at the same level as the keyboard that can accommodate both right and left handed users.
2.3.5 Fabric and Finish
Submit samples of all furniture fabric and finishes. Samples must be actual samples, not photographic representations, size must be a minimum of 3 by 3 inches. If necessary, provide larger size samples to clearly represent pattern. Label samples with fabric or finish code, furniture item code and name, manufacturer name, and color information. Fabric samples must also be labeled with fiber content and double rub testing information.
2.3.5.1 Fabric
a. Fabric must be from manufacturer's standard line and graded-in textile manufacturer's fabrics.
b. Provide a mid grade fabric. Example: Manufacturer available Grades 1 through 4 (even number of grades), provide Grade 3; manufacturer available Grades A through D (even number of grades), provide Grade C;
manufacturer available Grades A through E (odd number of grades), provide Grade C (middle grade).
c. Provide a topical or inherent soil retardant treatment where indicated.
d. Fabric for seating must comply with a minimum of 55,000 double rubs unless otherwise noted. Perform double rub testing in accordance with the ASTM D4157 Wyzenbeek Method.
e. Provide vinyl, polypropylene or similar type fabric for seating only if allowed in FF&E Package Attachment.
f. Pattern:
(1) Provide patterned upholstery fabric to help hide soiling.
SECTION 12 50 00.13 10 Page 9
(2) Provide patterns as specified in the FF&E Package Attachment.
g. See FF&E Package Attachment for additional information.
2.3.5.2 Finishes
Provide furniture finishes as listed below unless otherwise noted:
a. Finishes must be able to be cleaned with ordinary household cleaning solutions. Wood finishes must be able to be cleaned with damp cloth as directed by the manufacturer.
b. The finish of steel surfaces must be the manufacturer's most durable finish such as factory powder coat or baked enamel.
c. Grommet colors must be compatible and coordinated with desk, workstation, and table finish colors.
d. Finishes must be neutral in color.
e. Plastic laminate work surfaces and table tops must be neutral in color and must have a pattern to help hide soiling.
f. See FF&E Package Attachment for additional information.
2.4 FURNITURE LAYOUT
Provide furniture layout as indicated.
PART 3 EXECUTION
3.1 BUILDING EXAMINATION
Become familiar with details of the Work, inspect all areas and conditions under which furniture is to be installed, and coordinate scheduling of dedicated elevators and docks. Notify the Contracting Officer in writing of any conditions detrimental to the proper and timely completion of the installation. Work will proceed only when conditions have been corrected.
3.2 BUILDING PROTECTION
Protect building surfaces to prevent soiling and damage during delivery and installation. Any soiling and damage that occurs to the building during the installation of furniture must be cleaned and repaired, or replaced to its original condition and must be approved by the Contracting Officer.
3.3 INSTALLATION
3.3.1 Installation Drawings
Installation Drawings must include furniture layout, critical dimensions and locations of electrical and communications. Furniture layouts shall reflect field verified conditions. Drawings must be at 1/4 inch = 1 foot scale, unless otherwise specified. Provide typical plans and isometrics/elevations of desks and workstations at a scale of 1/2 inch = 1 foot. When applicable, provide desk and workstation electrical and communications locations. When applicable include controlled-circuit identification for each furniture receptacle and coordinate with the
SECTION 12 50 00.13 10 Page 10 building electrical system circuits in accordance with ASHRAE 90.1 - IP .
Critical dimensions include, but are not limited to clearances and aisle widths. Drawings must include layout for furniture systems workstations for coordination purposes. Label furniture with furniture item code identified in this Specification. Submit grommet, power and communication units, and wire management locations.
3.3.2 Furniture Installation Procedures
Complete installation in accordance with manufacturer's installation instructions, assembly manuals, warranty requirements and approved Installation Drawings. Also comply with the following requirements:
a. Use material handling equipment with rubber wheels.
b. Furniture and components must be installed level, plumb, square, and with proper alignment with adjoining furniture.
c. Match keys to locks and check locking mechanisms.
d. Check drawers, doors, lighting, and other operable items and mechanisms for proper operation.
e. Remove all protective wrapping tape, residue, and related type items.
f. Securely interconnect furniture components where required.
g. Securely attach and anchor furniture components to the building when required.
h. Securely anchor furniture such as shelving and storage units to the building when required by the manufacturer.
i. All items with an electrical plug, such as but not limited to task lighting and tables with electrical power, must be fully operational .
j. All hardwired furniture, such as but not limited to furniture systems, must be fully operational. Verify that voltage is present in electrical outlets. Verify controlled-circuit outlets are properly configured in accordance with the Installation Drawings.
k. Furniture must not block SIPRNET jacks or the jack enclosures on walls. Report conflicts to Contracting Officer to discuss resolution.
l. Upon completion of installation, all furniture must be completely cleaned, finished, leveled, aligned, operational and functional.
3.3.3 Furniture Communications Installation
Provide all Information/Technology (IT) cables (i.e., SIPRNET, NIPRNET, J-WIC'S, etc.) and phone wiring up to and including the face plate/box of all furniture as required and the services to install the cables, wiring and face plates/boxes in the furniture. Coordinate cable type, cable jacket and outlet jack color with Section 27 10 00 BUILDING TELECOMMUNICATIONS CABLING SYSTEM. Furniture communication installers must be on-site to install communication cables, wiring and other components for furniture during furniture installation. Coordinate the TIA-568-C.2 pin/pair assignments for communication outlets to match the
SECTION 12 50 00.13 10 Page 11 configuration of the building's non-furniture outlets; coordinate with Contracting Officer. All items with a communication interface must be fully operational. Installation of Information/Technology (IT) wiring, cables and face plates/boxes in the furniture will be completed by others.
3.4 CLEANING
Remove all packing materials and other trash from the Job Site. Upon completion of installation, all products must be clean, including inside all drawers and doors, and the area must be free of debris and left in a clean and neat condition. Any defects in or damage to furniture must be repaired or replaced and approved by the Contracting Officer. Damaged products that cannot be satisfactorily repaired must be replaced. Correct any problems with assembly and installation. Prior to any furniture repair, replacement, and/or assembly and installation corrections, protect the building surfaces.
3.5 OPERATION AND MAINTENANCE MANUALS
Submit the Furniture, Data Package 1 in accordance with Section 01 78 23 OPERATION AND MAINTENANCE DATA and include the following:
3.5.1 Assembly Manuals
Describe assembly and re-configuration procedures. Provide three sets of installation video tapes if available.
3.5.2 Installation Instructions
Provide a copy of the instructions used to install the furniture. Also describe any special procedures or helpful hints learned during the installation process.
3.5.3 Maintenance Manuals
Describe proper cleaning and minor repair procedures, include cleaning instructions for fabrics.
3.5.4 Electrical System Manuals
Describe the functions, configuration, and maintenance of the furniture electrical system (power, communication, and data). This information may be included in the assembly or maintenance manuals.
3.5.5 Special Tools
Provide three sets of special tools necessary for assembly and disassembly of furniture and components from each manufacturer. Mark tool(s) with manufacturer and product information.
3.5.6 Furniture Drawings
Provide hard copy and electronic, showing installed furniture layout.
Include all modifications. Provide electronic copies on a CD-ROM.
Coordinate type (such as but not limited to Microstation, AutoCad, and Revit) and version required with User. Include critical dimensions, and locations of building and furniture electrical and communications.
Provide drawings at 1/4 inch = 1 foot scale, unless otherwise specified.
Provide typical plans and isometrics/elevations of workstations at a scale
SECTION 12 50 00.13 10 Page 12 of 1/2 inch = 1 foot. Code all furniture with furniture item code identified in this Specification.
3.5.7 Furniture Listing
Provide complete listing, hard copy…