44026-E10.pdf

PDF 147 KB Posted

Attached to
Armor OSUT 2 Federal contract opportunity
Solicitation number
W911SF-19-R-0020
Issued by
Department of the Army Materiel Command Mission and Installation Contracting Command Fort Benning

About this file

E10

View the file

Other files for this federal contract opportunity

Other files attached to Armor OSUT 2, newest first.
File Type Posted
ARMOR_OSUT_1_-_5_Pre_Award_Addendum_1.pdf PDF
W911SF19R00200004.pdf PDF
W911SF19R00200003.pdf PDF
44026_Morris_Oscar_5_Nad_83_Site_Plan_Model_Amended_12_July_2019.pdf PDF
ARMOR_OSUT_Site_Visit_Attendees.pdf PDF
ARMOR_OSUT_1_-_5_General_Questions.pdf PDF
Blank_Bid_Breakdown_Form.xlsx XLSX spreadsheet
OSUT_31_11_00_Clearing_and_Grubbing.pdf PDF
OSUT_01_62_35_Recycled_Recovered_Materails.pdf PDF
44026-E13.pdf PDF
OSUT_01_74_19_Construction_and_Demolition_Waste_Management.pdf PDF
SIT_ED-01.pdf PDF
44026-E11.pdf PDF
OSUT_01_57_20_Environmental_Protection.pdf PDF
W911SF-19-R-0020-0001,_ARMOR_OSUT_2,_wdr,_1Jul19.pdf PDF
AR_OUST_Proj_2_Spec_Cover_and_Table_of_Contents_FT_Benn.docx DOCX document
OSUT_01_78_23_Operation_an_Maintenace_Data.pdf PDF
44026-E4.pdf PDF
OSUT_32_11_23_Aggregate_Base_Course.pdf PDF
OSUT_32_13_13_Portland_Cement_Concrete_Pavement.pdf PDF
Downrange_Power_&_Data_Distribution_-_General.pdf PDF
44026-E1.pdf PDF
OSUT_01_33_00_Submittal_Procedure.pdf PDF
OSUT_31_31_16_Soil_Treatment_for_Subt_Termites_Control.pdf PDF
26_20_00.pdf PDF
Stationary_Infantry_Target_(SIT).pdf PDF
OSUT_01_11_0_Summary_of_Work.pdf PDF
OSUT_01_35_29_Safety_and_Occupational_Health_Requirements.pdf PDF
44026-E5.pdf PDF
26_00_00.00_20.pdf PDF
OSUT_32_31_13_High-Security_Chain_Link_Fences.pdf PDF
OSUT_31_32_11_Soil_Surface_Erosion_Control.pdf PDF
OSUT_01_50_00_Temporary_Construction_Faclities_and_Controls.pdf PDF
26_24_16.00_40.pdf PDF
Downrange_Power_&_Data_Distribution_-_Over_300M.pdf PDF
44026_Elec.pdf PDF
44026-E6.pdf PDF
OSUT_01_57_23_Storm_Water_Pollution_Prevention.pdf PDF
44026-E12.pdf PDF
OSUT_32_92_19_Seeding.pdf PDF
OSUT_26_00_00_Basic_Electrical_Materials_and_Methods.pdf PDF
OSUT_26_20_00_Interior_Distribution_System.pdf PDF
SIT_Clusters_ED-05.pdf PDF
44026-E2.pdf PDF
OSUT_31_23_00_Excavation_and_Fill.pdf PDF
AR_OSUT_2_SOW_Oscar_5_,_wdr,_18Jun19.pdf PDF
AR_OSUT_2_WD_GA20190118_dtd_12Apr19,_wdr,_26Jun19.pdf PDF
W911SF-19-R-0020,_ARMOR_OSUT_2,_wdr,_27Jun19.pdf PDF
AR_OSUT__2_General_Requirements.pdf PDF
SOW_Cover_Page_-_Oscar_5.pdf PDF
Show all 50

Armor OSUT 2 has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SAT X

SPACE NOT REQUIRED.

DEVICE BY OTHERS.

10" X 10’ SPACE FOR

2 NO SCALE

1 NO SCALESIT EMPLACEMENT ELEVATION

GENERAL NOTES FOR SIT:

NO SCALETYPICAL MASTER TARGET DATA PANEL

NO SCALE

TYPICAL TARGET DATA PANELTYPICAL ENCLOSURE COVERSECTION

SCALE: NONESCALE: NONE

ENTERING MASTER TARGET DATA PANEL)

BOX FROM UNDERGROUND. (TYPICAL FOR ALL CABLE

PROVIDE CABLE SEAL FITTINGS AROUND CABLES ENTERING

TERMINATE WITH A MALE RJ-45 CONNECTOR.

TO MASTER TARGET DATA PANEL BASE PLATE GROUND.

MTDP AND PROVIDE STRAIN RELIEF. BOND CABLE SHIELD

TDPS AND MASTER TARGET DATA PANELS. 12" SLACK IN

DIRECT BURIAL CATEGORY 5E SHIELDED CABLES BETWEEN

BURIAL SHIELDED CATEGORY 5E CABLES.

CONDUIT WITH WATERTIGHT BOX CONNECTOR FOR DIRECT

GROUND BAR IN LOAD CENTER.

#6 AWG. COPPER GROUNDING CONDUCTOR IN CONDUIT TO

CABLES.

CONDUIT AND WATERTIGHT BOX CONNECTOR FOR FIBER OPTIC

FIBER EACH.

FIBER OPTIC CABLE BUFFER TUBES WITH 6-STRANDS OF

PROTECTOR. ALL CONNECTORS NOT SHOWN FOR CLARITY.

FIELD INSTALLABLE "SC" TYPE CONNECTORS WITH BEND

STRANDS WITH "SC" CONNECTORS.

GENERAL NOTE: FIBER TERMINATIONS, TERMINATE ALL

INTERRUPTING DEVICE.

SHALL BE WIRED AHEAD OF ANY GROUND FAULT

1-PHASE SERVICE TO DUPLEX RECEPTACLE. RECEPTACLE

3#12, 1#12G.�"C FROM LOAD CENTER FOR 120 VOLT,

DEVICE PLATE.

STANDARD SINGLE-GANG METAL BOX AND GALVANIZED STEEL

AMP, 125 VOLT, 2 POLE, 3 WIRE GROUNDING TYPE IN A

DUPLEX RECEPTACLE (DPR-DATA POWER RECEPTACLE) - 20

REFER TO DETAIL 3 ON SHEET ES-504.

#6 AWG. COPPER GROUNDING CONDUCTOR TO GROUND ROD.

GROUND BAR - SECURE TO METAL BASE PLATE.

KEYED NOTES FOR MTDP & TDP PANELS:

WITH WEATHERPROOF COVER

TPR IN EXTERIOR ENCLOSURE

(3" X 4" X 3")

(MR) IN EXTERIOR ENCLOSURE

MAINTENANCE RECEPTACLE

WITH WEATHERPROOF COVERS.

APR(S) IN EXTERIOR ENCLOSURES

MASTER TARGET DATA PANEL (MTDP)

LOADCENTER (LC)

NEMA 3R

CONDUIT

RIGID METAL

WALL

EMPLACEMENT

FOR ELECTRICAL EQUIPMENT.

120" MAX. SEE NOTE 8. AREA

PLACEMENT.

DETAILS FOR EXACT

TYPICAL OF 2. SEE CIVIL

ELECTRICAL BLOCKOUT

SEE NOTE 6

EMPLACEMENT WALL

CONDUIT. SEE NOTE 1.

SOURCE IN 2" PVC

120/240V POWER

POWER CABLE FROM

TARGET GROUND ROD

GROUND ROD

WELD TO THE TARGET

LOADCENTER, EXOTHERMIC

GROUND BAR OF

PVC CONDUIT BOND TO

#6 AWG BARE COPPER IN 1"

(IF REQUIRED)

TO NEXT TARGET PIT. (SEE NOTE 1)

POWER CABLE IN 2" PVC CONDUIT

LOCATIONS (NEMA L14-20R)

WEATHERPROOF COVER FOR WET

ENCLOSURE WITH GASKETED

IN WEATHERPROOF 6" x 4" METALLIC

120/240V, 20A, 4 WIRE, TWIST LOCK

TARGET POWER RECEPTACLE (TPR)

8"W X 11"H X 4"D

LOADCENTER, MAX SIZE

WALL MOUNTED NEMA 3R,

GROUNDING TO TARGET

6’ COILED FOR

CONDUCTORFROM LC.

#6 AWG BARE COPPER

MIN.

2"

MIN

12"

NOTES 1-3.

FIBER OPTIC CABLES SEE

1�" PVC CONDUIT WITH

8" MIN

MIN

2"

2"

MIN

DATA PANEL (MTDP)

MASTER TARGET

SEE NOTE 7

LOCATED INSIDE PANEL.

RECEPTACLE (DPR)

DATA POWER

ENCLOSURE WITH COVER

IN WEATHERPROOF

RECEPTACLE (MR)

GFCI MAINTENANCE

TYPICAL FOR 4

SIMULATORS, NCHMD, OR OTHER DEVICE.

USES: MECHANISM HEATERS,

WEATHERPROOF (4" X 4") ENCLOSURE.

COVER FOR WET LOCATIONS IN METALLIC

L5-20R) WITH GASKETED WEATHERPROOF

120V, 20A, 3 WIRE, TWIST LOCK (NEMA

AUXILIARY POWER RECEPTACLE (APR)

RGS CONDUIT (TYP)

24 25

152 (6")

610 (24")

TYPICAL DETAILS

REFERENCE ONLY

E10 ALL MTDPS.

9. PROVIDE SEAL FITTINGS AS SHOWN IN DETAIL 5 ON SHEET

8. MEASUREMENTS ARE IN INCHES UNLESS OTHERWISE NOTED.

RECEPTACLE TO AVOID NUISANCE TRIPPING.

7. WIRE THE DPR AHEAD OF THE GFCI MAINTENANCE

EMPLACEMENT ON A RANGE.

THE CIVIL AND ELECTRICAL DESIGNATIONS FOR EACH

6. PERMANENTLY LABEL THE EMPLACEMENT ACCORDING TO

FROM TOP OF EMPLACEMENT WALL.

5. ALL EQUIPMENT SHALL BE MOUNTED NO HIGHER THAN 2"

ROUTED IN.

4. ROUTE UNDER SLAB TO THE SAME TRENCH THE POWER IS

DIGGING INTO THE BERM.

OF BERM TO PREVENT CABLE DAMAGE FROM PROJECTILES

3. TYPICAL, CABLES/CONDUITS SHALL BE ROUTED FROM SIDE

WHEN REQUIRED.

2. EXTEND CONDUIT/CAT5E TO CLUSTER TARGETS OR SIMULATORS

1. CONDUITS SHALL EXTEND 5’ BEYOND EMPLACEMENT WALL.

HEX NUTS.

CENTRAL MEMBER STRAIN-RELIEF BRACKET WASHER AND

DETAIL 5 ON SHEET E10.

STEEL SOCKET HEAD CAP SCREWS AND WASHERS. SEE

STEEL DISCS, NEOPRENE SEALING RING AND STAINLESS

CONDUIT SEALING BUSHING WITH SLOTTED PVC COATED

ARMOR TO THE THE GROUNDING CLAMP.

GROUNDING CONNECTOR. CONNECT FIBER OPTIC CABLE

METALLIC CABLE SHEATH GROUNDING CLAMP AND

BRACKET.

RETENTION CLAMP. SECURE CABLE TO SHEATH RETENTION

CABLE(S), PREPARE CABLE AND INSTALL A SHEATH

ONE OR TWO 6-STRAND ARMORED TYPE FIBER OPTIC

CONNECTOR PATCH PANEL SUPPORT BRACKETS.

ENCLOSURE.

METAL BASE PLATE TO SECURE COMPONENTS INSIDE

DESTINATIONS.

INCOMING AND EXITING CABLES IDENTIFYING

GENERAL NOTE: PROVIDE PERMANENT LABELS ON

PANEL FOR FIELD INSTALLABLE CONNECTORS.

INJECTION-MOLDED PLASTIC CONNECTOR 12-PORT PATCH

RADIUS CONTROL GUIDES.

CABLE IDENTIFICATION DIRECTORY.

DUST-TIGHT SEAL.

SEAMLESS FOAM-IN-PLACE GASKET FOR A WATERTIGHT AND

SCREWS/CLAMPS.

CORROSION-RESISTANT STAINLESS STEEL CAPTIVE

HINGED, CLAMP-ON, OR BOLT-ON COVER WITH

TO AN IEC 529 IP66 RATING.

ENCLOSURE SHALL CARRY A NEMA 4 RATING IN ADDITION

STEEL SHEET METAL WITH A WALL MOUNT BRACKET.

ENCLOSURE SHALL BE 16 GUAGE MINIMUM GALVANIZED

D A

T E

S Y

M B

O L

R E

V

IS

IO

N S

B Y

DRAWN BY

APPROVED

DRAWING NUMBER SCALE

DATE

L&E NO:

NOTED

D. SAYLOR

K. CHAN

DIRECTORATEDIRECTORATE

OF PUBLIC WORKS

FORT BENNING, GEORGIA

STATIONARY INFANTRY TARGET

(SIT) PLAN

(TDP) DETAIL

(MTDP) DETAIL

E10

E10

E10

44026-E10

E10

STATIONARY INFANTRY TARGET (SIT) DETAIL

E10E10

TYP

E11E10

TYP

E11E10

E10E10

PEAK

SIT WITH THERMAL BLANKET

ADD 260V IF THERMAL BLANKET IS UTILIZED

700VA WILE RAISING OR LOWERING TARGET.

TYPE

EMPLACEMENT

TYPE

POWER FEED

PHASE

120/240V, SINGLE

260V

BLANKET

50VA THERMAL

LOAD

STATIC

LOAD

DESIGN

960VA

960VATOTAL

SIT EMPLACEMENT TARGET POWER TABLE

BID DOCUMENTS

35% DESIGN FORT BENNING, GEORGIA

PISTOL QUALIFICATION COURSE RANGE

CONVERT OSCAR 5 RANGE TO COMBAT

15 FEB 2019

File details come from the government source that posted it.