44026_Elec.pdf

PDF 7 MB Posted

Attached to
Armor OSUT 2 Federal contract opportunity
Solicitation number
W911SF-19-R-0020
Issued by
Department of the Army Materiel Command Mission and Installation Contracting Command Fort Benning

About this file

44026

View the file

Other files for this federal contract opportunity

Other files attached to Armor OSUT 2, newest first.
File Type Posted
Armor_OSUT_2_Questions.pdf PDF
Attachment_4_Performance_Assessment_Questionnaire.pdf PDF
W911SF19R00200003.pdf PDF
44026_Morris_Oscar_5_Nad_83_Site_Plan_Model_Amended_12_July_2019.pdf PDF
ARMOR_OSUT_Site_Visit_Attendees.pdf PDF
ARMOR_OSUT_1_-_5_General_Questions.pdf PDF
44026-E7.pdf PDF
OSUT_32_01_19_Field_Molded_Sealants_for_Sealing_Jts_In_Rigid_Pavg.pdf PDF
44026-E9.pdf PDF
DSIT_ED-01A.pdf PDF
OSUT_01_42_00_Sources_for_Referencece_Publications.pdf PDF
OSUT_01_50_61_Dust_Control.pdf PDF
44026-E8.pdf PDF
44026-E14.pdf PDF
OSUT_32_15_00_Aggregate_Surface_Course.pdf PDF
44026-E10.pdf PDF
OSUT_26_41_01_Lightning_Protection_System.pdf PDF
OSUT_31_00_00_Earthwork.pdf PDF
44026-E3.pdf PDF
OSUT_01_32_01_Project_Schedule.pdf PDF
OSUT_01_78_02_00_10_Closeout_Submittals.pdf PDF
OSUT_32_05_33_Landscape_Establishment.pdf PDF
OSUT_26_28_01_Coordinated_Power_System_Protection.pdf PDF
OSUT_31_11_00_Clearing_and_Grubbing.pdf PDF
OSUT_01_62_35_Recycled_Recovered_Materails.pdf PDF
44026-E13.pdf PDF
OSUT_01_74_19_Construction_and_Demolition_Waste_Management.pdf PDF
SIT_ED-01.pdf PDF
44026-E11.pdf PDF
OSUT_01_57_20_Environmental_Protection.pdf PDF
OSUT_01_35_29_Safety_and_Occupational_Health_Requirements.pdf PDF
44026-E5.pdf PDF
26_00_00.00_20.pdf PDF
OSUT_32_31_13_High-Security_Chain_Link_Fences.pdf PDF
OSUT_31_32_11_Soil_Surface_Erosion_Control.pdf PDF
OSUT_01_50_00_Temporary_Construction_Faclities_and_Controls.pdf PDF
26_24_16.00_40.pdf PDF
Downrange_Power_&_Data_Distribution_-_Over_300M.pdf PDF
44026-E6.pdf PDF
OSUT_01_57_23_Storm_Water_Pollution_Prevention.pdf PDF
44026-E12.pdf PDF
OSUT_32_92_19_Seeding.pdf PDF
OSUT_26_00_00_Basic_Electrical_Materials_and_Methods.pdf PDF
OSUT_26_20_00_Interior_Distribution_System.pdf PDF
SIT_Clusters_ED-05.pdf PDF
44026-E2.pdf PDF
Statement_of_Work_-_OSCAR_5_Civil.pdf PDF
Statement_of_Work_-_OSCAR_5_Electrical.pdf PDF
AR_OSUT_2_SOW_Oscar_5_,_wdr,_18Jun19.pdf PDF
AR_OSUT_2_WD_GA20190118_dtd_12Apr19,_wdr,_26Jun19.pdf PDF
Show all 50

Armor OSUT 2 has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

44026-E1

E1

SCALE OF FEET

030 30 60

N

1 SCALE: 30’ = 1’-0"

E1

M2

M2

M

M

M

M7 M

M

M

OVERALL ELECTRICAL SITE PLAN

LEGEND

SPECIAL ELECTRICAL KEYED NOTES:

OVERALL ELECTRICAL SITE PLAN

SIT (STATIONARY INFANTRY TARGET)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

SEE ELECTRICAL SCOPE OF WORK FOR MORE DETAILS.

ALL EXTERIOR MOUNTED LOAD CENTERS TO BE NEMA 3R.

MINIMIZED.

BIRD-NESTING SEASONS, 15 MARCH THROUGH 31 MAY, CLEARING AND GRUBBING OPERATIONS SHALL BE

CONTRACTOR MAY PERFORM CONSTRUCTION WORK WITHIN THE NON-CORE HABITAT AREA; HOWEVER, DURING

UXO AREA TO GAIN ACCESS TO OTHER CONSTRUCTION AREAS.

UNEXPLODED ORDANCE (UXO) AREA AT ANY TIME; HOWEVER, CONTRACTOR MAY USE EXISTING ROADS IN THE

CONTRACTOR SHALL NOT ENCROACH OR PERFORM ANT CONSTRUCTION OPERATIONS WITHIN THE LIMITS OF THE

NO SPLICING OF ELECTRICAL CABLES BETWEEN MANHOLES AND EMPLACEMENTS.

ROW OR LANE COMMON TRENCHING.

ALL RANGE AREA PRIMARY, SECONDARY ELECTRICAL AND COMMUNICATION CABLE SHALL BE INSTALLED IN

ENCASED DUCTS THREE (3) FEETS BEYOND ROAD ON EACH SIDE.

ALL CONDUITS CROSSING ROADS AND SERVICE DRIVES WILL BE CONCRETE ENCASED. EXTEND CONCRETE

FORT BENNING DIRECTORATE OF PUBLIC WORK (DPW).

ALL PRIMARY OUTAGE WILL BE COORDINATED WITH THE AREA OFFICE OF CORP. OF ENGINEERS AND

NO SPLICING OF CABLES BETWEEN THE EMPLACEMENTS IS ALLOWED.

PERCENT OF THE SUPPLYING TRANSFORMER’S SECONDARY VOLTAGE.

OPERATING VOLTAGE AT THE MOST DISTANT EMPLACEMENT OR TARGET SHOULD NOT BE LESS THAN 95

FROM THE EMPLACEMENT.

DIRECT BURIED CABLES SHALL FEED EMPLACEMENTS THROUGH CONDUIT THAT IS STUBBED OUT 5 FEET

PENETRATION.

ACTUAL DEPTH OF THE CABLES SHALL BE DEEP ENOUGH TO PREVENT DANAGE FROM THE PROJECTILE

CONCRETE ENCASED DUCT BANKS MUST BE USED WHENEVER TRENCHING UNDERNEATH ROAD SYSTEMS.

MUCH AS PRACTICAL TO MINIMUM DISTURBANCE.

DESIGNER SHOULD ROUTE THE TRENCHES ALONG THE ACCESS ROADS AND THE MAINTENANCE TRAILS AS

ROADS AND MAINTENANCE ROADS.

REDUCE THE AMOUNT OF TRENCHING ON DOWN RANGE BY PLACING ELECTRICAL TRENCHES ALONG COURSE

CENTER FEEDERS FROM ROC-TOWER POWER PANELS PRIOR TO DETERMINING THE FEEDER WIRE SIZE.

IT IS IMPORTANT THAT DETAILED VOLTAGE DROP CALCULATIONS BE PERFORMED ON ALL TARGET LOAD

RANGES.

CAN CARRY THE LOAD OF THE ENTIRE RANGE IF ONE FEEDER MUST BACK FEED TARGETS ON OTHER

PHASES TO RUN DOWN RANGE, AND THE PRIMARY FEEDERS SHOULD BE SIZED SUCH THAT EACH FEEDER

THE DESIGNER SHOULD CONSIDER PHASE IMBALANCE ON UTILITY SYSTEM WHEN SELECTING SELECTING

THE DESIGNER SHOULD CONSIDER THE MEANS TO BACK FEED TARGETS EVERYWHERE PRACTICAL.

BE CLEAR OF TREES, BUSHES, STUMPS, LEDGE, LARGE ROCKS AND OTHER IMPEDIMENTS.

ALL TRENCH LINES SHALL BE NOT LESS THAN TEN FEET FROM THE ROAD. THE TRENCH ROUTE MUST

REQUIREMENTS WITHOUT EXCEPTION.

ALL EXCAVATION AND ROADWAY WORK SHALL ADHERE TO OSHA, DOT, AND FLINT ELECTRIC SAFETY

BY THE LOCAL UTILITY.

THE MINIMUM CABLE DEPTHS FOR MEDIUM VOLTAGE POWER ARE 48-INCH OR THE DEPTHS DETERMINED

CODE HAS A MINIMUM REQUIREMENTS FOR TRENCHING DEPTHS. FOR DOWNRANGE PORTION OF RANGES

THE POWER AND DATA CABLES SHALL BE INSTALLED IN THE SAME TRENCH. THE NATIONAL ELECTRIC

THE OSCAR 5 (MORRIS RANGE). USE FIBER OPTIC COMMUNICATION DISTRIBUTION SYSTEM.

CONTRACTOR IS REQUIRED TO DESIGN THE DOWNGROUND POWER AND DATA DISTRIBUTION SYSTEMS FOR

ELECTRICAL DESIGN FOR THE GOVERNMENT APPROVAL BEFORE STARTING THEIR WORK.

THIS IS 1 35% DESIGN BID DOCUMENTS. CONTRACTOR IS REQUIRED TO SUBMIT THE 100%

S Y

M B

O L

D A

T E

B Y

R E

V I S I O

N S

DRAWN BY:

APPROVED BY:

D.SAYLOR

L&E NO:

DRAWING NUMBER: SCALE:

AS NOTED

DATE:

FORT BENNING, GEORGIA

FORT BENNING, GEORGIA

F I L

E N

A M

E

DIRECTORATE

OF PUBLIC WORKS

K. CHAN

15 FEB 2019

PISTOL QUALIFICATION COURSE RANGE

CONVERT OSCAR 5 RANGE TO COMBAT

44026-E2

E2

E2

NO SCALE1

D A

T E

S Y

M B

O L

R E

V

IS

IO

N S

B Y

DRAWN BY

APPROVED

DRAWING NUMBER SCALE

DATE

L&E NO:

NOTED

D. SAYLOR

K. CHAN

DIRECTORATEDIRECTORATE

OF PUBLIC WORKS

FORT BENNING, GEORGIA

SITSITSITSITSITSITSITSITSIT

SIT X SIT X SIT X SIT X SIT X SIT X SIT X SIT X SIT X

SITSITSITSITSITSITSITSITSIT

SIT X SIT X SIT X SIT X SIT X SIT X SIT X SIT X SIT X

FR9.2-7M FR9.1-7M FR8.2-7M FR8.1-7M FR7.1-7M FR6.2-7MFR7.2-7M

SITSITSITSITSITSITSITSITSIT

SIT X SIT X SIT X SIT X SIT X SIT X SIT X SIT X SIT X

STATIONARY INFANTRY TARGET (SIT) FROM LANE 1 TO LANE 15 AT 7M

BID DOCUMENTS

35% DESIGN

FR5.2-7M

SIT

SIT X

FR6.1-7M

SIT

SIT X

SIT

SIT X

TARGETS FROM 7M

ONELINE SECONDARY POWER DIAGRAM AT SIT

FP1.1-7M FR1.2-7M FR2.1-7M FR2.2-7M FR3.1-7M FR3.2-7M FR4.1-7M FR4.2-7M FR5.1-7M

FR10.1-7MFR10.2-7M

FR11.1-7M FR11.2-7M FR12.1-7M FR12.2-7M FR13.1-7M FR13.2-7M FR14.1-7M FR14.2-7M FR15.1-7M FR15.2-7M

TOWER

AT

PANEL

GOTO

AT TOWER

GOTO PANEL

FORT BENNING, GEORGIA

PISTOL QUALIFICATION COURSE RANGE

15 FEB 2019

44026-E3

E3

E3

NO SCALE1

D A

T E

S Y

M B

O L

R E

V

IS

IO

N S

B Y

DRAWN BY

APPROVED

DRAWING NUMBER SCALE

DATE

L&E NO:

NOTED

D. SAYLOR

K. CHAN

DIRECTORATEDIRECTORATE

OF PUBLIC WORKS

FORT BENNING, GEORGIA

SIT SIT

SITSITSITSITSITSITSIT

SIT X SIT X SIT X SIT X SIT X SIT X SIT X

SIT XSIT X

SITSITSITSIT

SITSITSITSITSIT

SIT X SIT X SIT X SIT X SIT X

SIT X SIT X SIT X SIT X

FR15-10M FR13-10M FR12-10MFR14-10M

SITSITSITSITSITSIT

SITSITSIT

SIT X SIT X SIT X

SIT X SIT X SIT X SIT X SIT X SIT X

FR1-10M FR2-10M FR3-10M FR4-10M FR5-10M FR6-10M FR7-10M

FR8-10MFR9-10M

TARGETS FROM 10M TO 12.5M

ONELINE SECONDARY POWER DIAGRAM AT SIT

BID DOCUMENTS

35% DESIGN

SIT

SIT X

FR10-10M

SIT

SIT X

FR11-10M

FR15-12.5MFR14-12.5MFR13-12.5MFR12-12.5MFR11-12.5MFR8-12.5M FR9-12.5M FR10-12.5M

FR1-12.5M FR2-12.5M FR3-12.5M FR4-12.5M FR5-12.5M FR6-12.5M

SIT

SIT X

FR7-12.5M

STATIONARY INFANTRY TARGET (SIT) FROM LANE 1 TO LANE 15 AT 10M AND 12.5M

TOWER

AT

PANEL

GOTO

AT TOWER

GOTO PANEL

AT TOWER

GOTO PANEL

AT TOWER

GOTO PANEL

FORT BENNING, GEORGIA

PISTOL QUALIFICATION COURSE RANGE

44026-E4

E4

E4

NO SCALE1

D A

T E

S Y

M B

O L

R E

V

IS

IO

N S

B Y

DRAWN BY

APPROVED

DRAWING NUMBER SCALE

DATE

L&E NO:

NOTED

D. SAYLOR

K. CHAN

DIRECTORATEDIRECTORATE

OF PUBLIC WORKS

FORT BENNING, GEORGIA

SIT SIT

SITSITSITSITSITSITSIT

SIT X SIT X SIT X SIT X SIT X SIT X SIT X

SIT XSIT X

SITSITSITSIT

SITSITSITSITSIT

SIT X SIT X SIT X SIT X SIT X

SIT X SIT X SIT X SIT X

SITSITSITSITSITSIT

SITSITSIT

SIT X SIT X SIT X

SIT X SIT X SIT X SIT X SIT X SIT X

TARGETS FROM 16.5M TO 23M

ONELINE SECONDARY POWER DIAGRAM AT SIT

BID DOCUMENTS

35% DESIGN

SIT

SIT X

SIT

SIT X

SIT

SIT X

STATIONARY INFANTRY TARGET (SIT) FROM LANE 1 TO LANE 15 AT 16.5M AND 23M

TOWER

AT

PANEL

GOTO

AT TOWER

GOTO PANEL

AT TOWER

GOTO PANEL

AT TOWER

GOTO PANEL

FR1-16.5M FR2-16.5M FR3-16.5M FR4-16.5M FR5-16.5M FR6-16.5M FR7-16.5M

FR15-16.5M FR14-16.5M FR13-16.5M FR12-16.5M FR11-16.5M FR10-16.5M FR9-16.5M FR8-16.5M

FR1-23M FR2-23M FR3-23M FR4-23M FR5-23M FR6-23M FR7-23M

FR8-23M FR9-23M FR10-23M FR11-23M FR12-23M FR13-23M FR14-23M FR15-23M

FORT BENNING, GEORGIA

PISTOL QUALIFICATION COURSE RANGE

44026-E5

E5

E5

NO SCALE1

D A

T E

S Y

M B

O L

R E

V

IS

IO

N S

B Y

DRAWN BY

APPROVED

DRAWING NUMBER SCALE

DATE

L&E NO:

NOTED

D. SAYLOR

K. CHAN

DIRECTORATEDIRECTORATE

OF PUBLIC WORKS

FORT BENNING, GEORGIA

SIT SIT

SITSITSITSITSITSITSIT

SIT X SIT X SIT X SIT X SIT X SIT X SIT X

SIT XSIT X

SITSITSITSIT

SITSITSITSITSIT

SIT X SIT X SIT X SIT X SIT X

SIT X SIT X SIT X SIT X

SITSITSITSITSITSIT

SITSITSIT

SIT X SIT X SIT X

SIT X SIT X SIT X SIT X SIT X SIT X

BID DOCUMENTS

35% DESIGN

SIT

SIT X

SIT

SIT X

SIT

SIT X

TOWER

AT

PANEL

GOTO

AT TOWER

GOTO PANEL

AT TOWER

GOTO PANEL

AT TOWER

GOTO PANEL

FR1-31M FR2-31M FR3-31M FR4-31M FR5-31M FR6-31M FR7-31M

FR8-31M FR9-31M FR10-31M FR11-31M FR12-31M FR13-31M FR14-31M FR15-31M

FR1-27M FR2-27M FR3-27M FR4-27M FR5-27M FR6-27M FR7-27M

FR15-27M FR14-27M FR13-27M FR12-27M FR11-27M FR10-27M FR9-27M FR8-27M

STATIONARY INFANTRY TARGET (SIT) FROM LANE 1 TO LANE 15 AT 27M AND 31M

TARGETS FROM 27M TO 31M

ONELINE SECONDARY POWER DIAGRAM AT SIT

FORT BENNING, GEORGIA

PISTOL QUALIFICATION RANGE

44026-E6

E6

E6

NO SCALE1

D A

T E

S Y

M B

O L

R E

V

IS

IO

N S

B Y

DRAWN BY

APPROVED

DRAWING NUMBER SCALE

DATE

L&E NO:

NOTED

D. SAYLOR

K. CHAN

DIRECTORATEDIRECTORATE

OF PUBLIC WORKS

FORT BENNING, GEORGIA

SITSITSITSITSITSITSITSITSIT

SIT X SIT X SIT X SIT X SIT X SIT X SIT X SIT X SIT X

SITSITSITSITSITSITSITSITSIT

SIT X SIT X SIT X SIT X SIT X SIT X SIT X SIT X SIT X

FR9.2-7M FR9.1-7M FR8.2-7M FR8.1-7M FR7.1-7M FR6.2-7MFR7.2-7M

SITSITSITSITSITSITSITSITSIT

SIT X SIT X SIT X SIT X SIT X SIT X SIT X SIT X SIT X

STATIONARY INFANTRY TARGET (SIT) FROM LANE 1 TO LANE 15 AT 7M

BID DOCUMENTS

35% DESIGN

FR5.2-7M

SIT

SIT X

FR6.1-7M

SIT

SIT X

SIT

SIT X

TARGETS FROM 7M

ONELINE SECONDARY POWER DIAGRAM AT SIT

FP1.1-7M FR1.2-7M FR2.1-7M FR2.2-7M FR3.1-7M FR3.2-7M FR4.1-7M FR4.2-7M FR5.1-7M

FR10.1-7MFR10.2-7M

FR11.1-7M FR11.2-7M FR12.1-7M FR12.2-7M FR13.1-7M FR13.2-7M FR14.1-7M FR14.2-7M FR15.1-7M FR15.2-7M

AT TOWER

GOTO DTR

TOWER

AT

DTR

GOTO

FORT BENNING, GEORGIA

PISTOL QUALIFICATION COURSE RANGE

44026-E7

E7

E7

NO SCALE1

D A

T E

S Y

M B

O L

R E

V

IS

IO

N S

B Y

DRAWN BY

APPROVED

DRAWING NUMBER SCALE

DATE

L&E NO:

NOTED

D. SAYLOR

K. CHAN

DIRECTORATEDIRECTORATE

OF PUBLIC WORKS

FORT BENNING, GEORGIA

SIT SIT

SITSITSITSITSITSITSIT

SIT X SIT X SIT X SIT X SIT X SIT X SIT X

SIT XSIT X

SITSITSITSIT

SITSITSITSITSIT

SIT X SIT X SIT X SIT X SIT X

SIT X SIT X SIT X SIT X

FR15-10M FR13-10M FR12-10MFR14-10M

SITSITSITSITSITSIT

SITSITSIT

SIT X SIT X SIT X

SIT X SIT X SIT X SIT X SIT X SIT X

FR1-10M FR2-10M FR3-10M FR4-10M FR5-10M FR6-10M FR7-10M

FR8-10MFR9-10M

TARGETS FROM 10M TO 12.5M

ONELINE SECONDARY POWER DIAGRAM AT SIT

BID DOCUMENTS

35% DESIGN

SIT

SIT X

FR10-10M

SIT

SIT X

FR11-10M

FR15-12.5MFR14-12.5MFR13-12.5MFR12-12.5MFR11-12.5MFR8-12.5M FR9-12.5M FR10-12.5M

FR1-12.5M FR2-12.5M FR3-12.5M FR4-12.5M FR5-12.5M FR6-12.5M

SIT

SIT X

FR7-12.5M

STATIONARY INFANTRY TARGET (SIT) FROM LANE 1 TO LANE 15 AT 10M AND 12.5M

AT TOWER

GOTO DTR

AT TOWER

GOTO DTR

AT TOWER

GOTO DTR

TOWER

AT

DTR

GOTO

FORT BENNING, GEORGIA

PISTOL QUALIFICATION COURSE RANGE

44026-E8

E8

E8

NO SCALE1

D A

T E

S Y

M B

O L

R E

V

IS

IO

N S

B Y

DRAWN BY

APPROVED

DRAWING NUMBER SCALE

DATE

L&E NO:

NOTED

D. SAYLOR

K. CHAN

DIRECTORATEDIRECTORATE

OF PUBLIC WORKS

FORT BENNING, GEORGIA

SIT SIT

SITSITSITSITSITSITSIT

SIT X SIT X SIT X SIT X SIT X SIT X SIT X

SIT XSIT X

SITSITSITSIT

SITSITSITSITSIT

SIT X SIT X SIT X SIT X SIT X

SIT X SIT X SIT X SIT X

SITSITSITSITSITSIT

SITSITSIT

SIT X SIT X SIT X

SIT X SIT X SIT X SIT X SIT X SIT X

TARGETS FROM 16.5M TO 23M

ONELINE SECONDARY POWER DIAGRAM AT SIT

BID DOCUMENTS

35% DESIGN

SIT

SIT X

SIT

SIT X

SIT

SIT X

STATIONARY INFANTRY TARGET (SIT) FROM LANE 1 TO LANE 15 AT 16.5M AND 23M

FR1-16.5M FR2-16.5M FR3-16.5M FR4-16.5M FR5-16.5M FR6-16.5M FR7-16.5M

FR15-16.5M FR14-16.5M FR13-16.5M FR12-16.5M FR11-16.5M FR10-16.5M FR9-16.5M FR8-16.5M

FR1-23M FR2-23M FR3-23M FR4-23M FR5-23M FR6-23M FR7-23M

FR8-23M FR9-23M FR10-23M FR11-23M FR12-23M FR13-23M FR14-23M FR15-23M

AT TOWER

GOTO DTR

AT TOWER

GOTO DTR

AT TOWER

GOTO DTR

TOWER

AT

DTR

GOTO

FORT BENNING, GEORGIA

PISTOL QUALIFICATION COURSE RANGE

44026-E9

E9

E9

NO SCALE1

D A

T E

S Y

M B

O L

R E

V

IS

IO

N S

B Y

DRAWN BY

APPROVED

DRAWING NUMBER SCALE

DATE

L&E NO:

NOTED

D. SAYLOR

K. CHAN

DIRECTORATEDIRECTORATE

OF PUBLIC WORKS

FORT BENNING, GEORGIA

SIT SIT

SITSITSITSITSITSITSIT

SIT X SIT X SIT X SIT X SIT X SIT X SIT X

SIT XSIT X

SITSITSITSIT

SITSITSITSITSIT

SIT X SIT X SIT X SIT X SIT X

SIT X SIT X SIT X SIT X

SITSITSITSITSITSIT

SITSITSIT

SIT X SIT X SIT X

SIT X SIT X SIT X SIT X SIT X SIT X

BID DOCUMENTS

35% DESIGN

SIT

SIT X

SIT

SIT X

SIT

SIT X

FR1-31M FR2-31M FR3-31M FR4-31M FR5-31M FR6-31M FR7-31M

FR8-31M FR9-31M FR10-31M FR11-31M FR12-31M FR13-31M FR14-31M FR15-31M

FR1-27M FR2-27M FR3-27M FR4-27M FR5-27M FR6-27M FR7-27M

FR15-27M FR14-27M FR13-27M FR12-27M FR11-27M FR10-27M FR9-27M FR8-27M

STATIONARY INFANTRY TARGET (SIT) FROM LANE 1 TO LANE 15 AT 27M AND 31M

TARGETS FROM 27M TO 31M

ONELINE SECONDARY POWER DIAGRAM AT SIT

AT TOWER

GOTO DTR

AT TOWER

GOTO DTR

AT TOWER

GOTO DTR

TOWER

AT

DTR

GOTO

FORT BENNING, GEORGIA

PISTOL QUALIFICATION COURSE RANGE

SAT X

SPACE NOT REQUIRED.

DEVICE BY OTHERS.

10" X 10’ SPACE FOR

2 NO SCALE

1 NO SCALESIT EMPLACEMENT ELEVATION

GENERAL NOTES FOR SIT:

NO SCALETYPICAL MASTER TARGET DATA PANEL

NO SCALE

TYPICAL TARGET DATA PANELTYPICAL ENCLOSURE COVERSECTION

SCALE: NONESCALE: NONE

ENTERING MASTER TARGET DATA PANEL)

BOX FROM UNDERGROUND. (TYPICAL FOR ALL CABLE

PROVIDE CABLE SEAL FITTINGS AROUND CABLES ENTERING

TERMINATE WITH A MALE RJ-45 CONNECTOR.

TO MASTER TARGET DATA PANEL BASE PLATE GROUND.

MTDP AND PROVIDE STRAIN RELIEF. BOND CABLE SHIELD

TDPS AND MASTER TARGET DATA PANELS. 12" SLACK IN

DIRECT BURIAL CATEGORY 5E SHIELDED CABLES BETWEEN

BURIAL SHIELDED CATEGORY 5E CABLES.

CONDUIT WITH WATERTIGHT BOX CONNECTOR FOR DIRECT

GROUND BAR IN LOAD CENTER.

#6 AWG. COPPER GROUNDING CONDUCTOR IN CONDUIT TO

CABLES.

CONDUIT AND WATERTIGHT BOX CONNECTOR FOR FIBER OPTIC

FIBER EACH.

FIBER OPTIC CABLE BUFFER TUBES WITH 6-STRANDS OF

PROTECTOR. ALL CONNECTORS NOT SHOWN FOR CLARITY.

FIELD INSTALLABLE "SC" TYPE CONNECTORS WITH BEND

STRANDS WITH "SC" CONNECTORS.

GENERAL NOTE: FIBER TERMINATIONS, TERMINATE ALL

INTERRUPTING DEVICE.

SHALL BE WIRED AHEAD OF ANY GROUND FAULT

1-PHASE SERVICE TO DUPLEX RECEPTACLE. RECEPTACLE

3#12, 1#12G.�"C FROM LOAD CENTER FOR 120 VOLT,

DEVICE PLATE.

STANDARD SINGLE-GANG METAL BOX AND GALVANIZED STEEL

AMP, 125 VOLT, 2 POLE, 3 WIRE GROUNDING TYPE IN A

DUPLEX RECEPTACLE (DPR-DATA POWER RECEPTACLE) - 20

REFER TO DETAIL 3 ON SHEET ES-504.

#6 AWG. COPPER GROUNDING CONDUCTOR TO GROUND ROD.

GROUND BAR - SECURE TO METAL BASE PLATE.

KEYED NOTES FOR MTDP & TDP PANELS:

WITH WEATHERPROOF COVER

TPR IN EXTERIOR ENCLOSURE

(3" X 4" X 3")

(MR) IN EXTERIOR ENCLOSURE

MAINTENANCE RECEPTACLE

WITH WEATHERPROOF COVERS.

APR(S) IN EXTERIOR ENCLOSURES

MASTER TARGET DATA PANEL (MTDP)

LOADCENTER (LC)

NEMA 3R

CONDUIT

RIGID METAL

WALL

EMPLACEMENT

FOR ELECTRICAL EQUIPMENT.

120" MAX. SEE NOTE 8. AREA

PLACEMENT.

DETAILS FOR EXACT

TYPICAL OF 2. SEE CIVIL

ELECTRICAL BLOCKOUT

SEE NOTE 6

EMPLACEMENT WALL

CONDUIT. SEE NOTE 1.

SOURCE IN 2" PVC

120/240V POWER

POWER CABLE FROM

TARGET GROUND ROD

GROUND ROD

WELD TO THE TARGET

LOADCENTER, EXOTHERMIC

GROUND BAR OF

PVC CONDUIT BOND TO

#6 AWG BARE COPPER IN 1"

(IF REQUIRED)

TO NEXT TARGET PIT. (SEE NOTE 1)

POWER CABLE IN 2" PVC CONDUIT

LOCATIONS (NEMA L14-20R)

WEATHERPROOF COVER FOR WET

ENCLOSURE WITH GASKETED

IN WEATHERPROOF 6" x 4" METALLIC

120/240V, 20A, 4 WIRE, TWIST LOCK

TARGET POWER RECEPTACLE (TPR)

8"W X 11"H X 4"D

LOADCENTER, MAX SIZE

WALL MOUNTED NEMA 3R,

GROUNDING TO TARGET

6’ COILED FOR

CONDUCTORFROM LC.

#6 AWG BARE COPPER

MIN.

2"

MIN

12"

NOTES 1-3.

FIBER OPTIC CABLES SEE

1�" PVC CONDUIT WITH

8" MIN

MIN

2"

2"

MIN

DATA PANEL (MTDP)

MASTER TARGET

SEE NOTE 7

LOCATED INSIDE PANEL.

RECEPTACLE (DPR)

DATA POWER

ENCLOSURE WITH COVER

IN WEATHERPROOF

RECEPTACLE (MR)

GFCI MAINTENANCE

TYPICAL FOR 4

SIMULATORS, NCHMD, OR OTHER DEVICE.

USES: MECHANISM HEATERS,

WEATHERPROOF (4" X 4") ENCLOSURE.

COVER FOR WET LOCATIONS IN METALLIC

L5-20R) WITH GASKETED WEATHERPROOF

120V, 20A, 3 WIRE, TWIST LOCK (NEMA

AUXILIARY POWER RECEPTACLE (APR)

RGS CONDUIT (TYP)

24 25

152 (6")

610 (24")

TYPICAL DETAILS

REFERENCE ONLY

E10 ALL MTDPS.

9. PROVIDE SEAL FITTINGS AS SHOWN IN DETAIL 5 ON SHEET

8. MEASUREMENTS ARE IN INCHES UNLESS OTHERWISE NOTED.

RECEPTACLE TO AVOID NUISANCE TRIPPING.

7. WIRE THE DPR AHEAD OF THE GFCI MAINTENANCE

EMPLACEMENT ON A RANGE.

THE CIVIL AND ELECTRICAL DESIGNATIONS FOR EACH

6. PERMANENTLY LABEL THE EMPLACEMENT ACCORDING TO

FROM TOP OF EMPLACEMENT WALL.

5. ALL EQUIPMENT SHALL BE MOUNTED NO HIGHER THAN 2"

ROUTED IN.

4. ROUTE UNDER SLAB TO THE SAME TRENCH THE POWER IS

DIGGING INTO THE BERM.

OF BERM TO PREVENT CABLE DAMAGE FROM PROJECTILES

3. TYPICAL, CABLES/CONDUITS SHALL BE ROUTED FROM SIDE

WHEN REQUIRED.

2. EXTEND CONDUIT/CAT5E TO CLUSTER TARGETS OR SIMULATORS

1. CONDUITS SHALL EXTEND 5’ BEYOND EMPLACEMENT WALL.

HEX NUTS.

CENTRAL MEMBER STRAIN-RELIEF BRACKET WASHER AND

DETAIL 5 ON SHEET E10.

STEEL SOCKET HEAD CAP SCREWS AND WASHERS. SEE

STEEL DISCS, NEOPRENE SEALING RING AND STAINLESS

CONDUIT SEALING BUSHING WITH SLOTTED PVC COATED

ARMOR TO THE THE GROUNDING CLAMP.

GROUNDING CONNECTOR. CONNECT FIBER OPTIC CABLE

METALLIC CABLE SHEATH GROUNDING CLAMP AND

BRACKET.

RETENTION CLAMP. SECURE CABLE TO SHEATH RETENTION

CABLE(S), PREPARE CABLE AND INSTALL A SHEATH

ONE OR TWO 6-STRAND ARMORED TYPE FIBER OPTIC

CONNECTOR PATCH PANEL SUPPORT BRACKETS.

ENCLOSURE.

METAL BASE PLATE TO SECURE COMPONENTS INSIDE

DESTINATIONS.

INCOMING AND EXITING CABLES IDENTIFYING

GENERAL NOTE: PROVIDE PERMANENT LABELS ON

PANEL FOR FIELD INSTALLABLE CONNECTORS.

INJECTION-MOLDED PLASTIC CONNECTOR 12-PORT PATCH

RADIUS CONTROL GUIDES.

CABLE IDENTIFICATION DIRECTORY.

DUST-TIGHT SEAL.

SEAMLESS FOAM-IN-PLACE GASKET FOR A WATERTIGHT AND

SCREWS/CLAMPS.

CORROSION-RESISTANT STAINLESS STEEL CAPTIVE

HINGED, CLAMP-ON, OR BOLT-ON COVER WITH

TO AN IEC 529 IP66 RATING.

ENCLOSURE SHALL CARRY A NEMA 4 RATING IN ADDITION

STEEL SHEET METAL WITH A WALL MOUNT BRACKET.

ENCLOSURE SHALL BE 16 GUAGE MINIMUM GALVANIZED

D A

T E

S Y

M B

O L

R E

V

IS

IO

N S

B Y

DRAWN BY

APPROVED

DRAWING NUMBER SCALE

DATE

L&E NO:

NOTED

D. SAYLOR

K. CHAN

DIRECTORATEDIRECTORATE

OF PUBLIC WORKS

FORT BENNING, GEORGIA

STATIONARY INFANTRY TARGET

(SIT) PLAN

(TDP) DETAIL

(MTDP) DETAIL

E10

E10

E10

44026-E10

E10

STATIONARY INFANTRY TARGET (SIT) DETAIL

E10E10

TYP

E11E10

TYP

E11E10

E10E10

PEAK

SIT WITH THERMAL BLANKET

ADD 260V IF THERMAL BLANKET IS UTILIZED

700VA WILE RAISING OR LOWERING TARGET.

TYPE

EMPLACEMENT

TYPE

POWER FEED

PHASE

120/240V, SINGLE

260V

BLANKET

50VA THERMAL

LOAD

STATIC

LOAD

DESIGN

960VA

960VATOTAL

SIT EMPLACEMENT TARGET POWER TABLE

BID DOCUMENTS

35% DESIGN FORT BENNING, GEORGIA

PISTOL QUALIFICATION COURSE RANGE

TARGET POWER RECEPTACLE (TPR) AUXILIARY POWER RECEPTACLE (APR)

W

G G

X

W

Y

ENCLOSURE

INSIDE

ENCLOSURE

OUTSIDE

NOTE BELOW

BUSHING, SEE

NEOPHRENE

NUT

PACKING

CABLE

LOCKNUT

GASKET

SEALING

BODY

SEAL-FITTING

CONDUIT

SPRING DOOR (TYPICAL)

SELF CLOSING

PANELBOARD

RIGID CONDUIT TO

GASKET (TYPICAL)

ONE PIECE EPDM

RECEPTACLE

NEMA L5-20R

120/240V

BOXES WITH WEATHERPROOF WHILE IN USE COVERS.

PROVIDE OUTLETS IN WEATHERPROOF RIGID METALLIC

NOTE:

BOXES WITH WEATHERPROOF WHILE IN USE COVERS.

PROVIDE OUTLETS IN WEATHERPROOF RIGID METALLIC

NOTE:

SPRING DOOR (TYPICAL)

SELF CLOSING

PANELBOARD

RIGID CONDUIT TO

GASKET (TYPICAL)

ONE PIECE EPDM

RECEPTACLE

NEMA L14-20R

120/240V

CENTER HOLE

CONCRETE COVER WITH

CRUSHED STONE

GROUND CONNECTOR

(TYPICAL)

#1/0 AWG BARE COPPER

GROUND ROD

CONNECT TO NEXT

GROUND ROD 3/4" x 10’

COPPER CLAD STEEL

GROUND ROD

CONNECT TO NEXT

OF STATIC GROUND WIRE

CLEAR FOR CONNECTION

LEAVE THE TOP 2" OF ROD

TO PANEL

CONDUCTORS

CIRCUIT

OUTLET

TO NEXT TARGET

EXTEND CIRCUIT

BOX

OUTLET

TARGET

GND

SYS

GND

EQ

TPR APR

10" MIN

A

N

B

G

PIPE

CONCRETE

PRECAST

W

G

W

X

G

Y

TPR APR

REMOVAL OF THE RECEPTACLE WOULD INTERRUPT THE CONTINUITY.

GROUNDING CONDUCTORS SHALL NOT DEPEND ON THE RECEPTACLE CONNECTION, WHERE

THROUGH THE OTHER RECEPTACLE. THE CONTINUITY OF THE NEUTRAL AND EQUIPMENT

EACH RECEPTACLE SHALL BE TAPPED FROM THE CIRCUIT CONDUCTORS AND NOT CONNECTED

SECTION-CABLE SEAL-FITTING5

NO SCALE

NO SCALE

TYPICAL DETAIL SYMBOL1

NO SCALE

TYPICAL DETAIL SYMBOL

NO SCALE

GROUND ROD WELL DETAIL 4

NO SCALE

TARGET OUTLET WIRING DIAGRAM

TYPICAL DETAILS

44026-E11

E11 E11 E11

E11E11

REFERENCE ONLY

E11

D A

T E

S Y

M B

O L

R E

V

IS

IO

N S

B Y

DRAWN BY

APPROVED

DRAWING NUMBER SCALE

DATE

L&E NO:

NOTED

D. SAYLOR

K. CHAN

DIRECTORATEDIRECTORATE

OF PUBLIC WORKS

FORT BENNING, GEORGIA

BID DOCUMENTS

35% DESIGN

TYPICAL RECEPTACLE AND WIRING DETAILS

FORT BENNING, GEORGIA

PISTOL QUALIFICATION COURSE RANGE

44026-E12

E12

D A

T E

S Y

M B

O L

R E

V

IS

IO

N S

B Y

DRAWN BY

APPROVED

DRAWING NUMBER SCALE

DATE

L&E NO:

NOTED

D. SAYLOR

K. CHAN

DIRECTORATEDIRECTORATE

OF PUBLIC WORKS

FORT BENNING, GEORGIA

NO SCALE

TARGET (SIT) DETAILS

TYPICAL STATIONARY INFANTRY

E12

(SIT) DETAILS

TYPICAL STATIONARY INFANTRY TARGET

BID DOCUMENTS

35% DESIGN

FORT BENNING, GEORGIA

PISTOL QUALIFICATION COURSE RANGE

44026-E13

E13

D A

T E

S Y

M B

O L

R E

V

IS

IO

N S

B Y

DRAWN BY

APPROVED

DRAWING NUMBER SCALE

DATE

L&E NO:

NOTED

D. SAYLOR

K. CHAN

DIRECTORATEDIRECTORATE

OF PUBLIC WORKS

FORT BENNING, GEORGIA

NO SCALE

1 TYPICAL STATIONARY INFANTRY

E13

CLUSTER TARGET DETAILS

TARGET DETAILS

TYPICAL STATIONARY INFANTRY CLUSTER

BID DOCUMENTS

35% DESIGN

FORT BENNING, GEORGIA

PISTOL QUALIFICATION COURSE RANGE

TYPICAL DETAILS

GENERAL NOTES FOR DIRECT BURIED CABLE DETAILS:

OFFICER IF ACTUAL CONSTRUCTION ISSUES MAY CAUSE RUNS TO EXCEED 90 METERS.

7. COPPER CAT 5e CABLE RUNS SHALL BE NO LONGER THAN 90 METERS. CONTACT THE CONTRACTING

6. AFTER INSTALLATION REPAIR ALL SURFACES TO MATCH EXISITING.

CODE.

5. INSTALLATION SHALL BE IN ACCORDANCE WITH NFPA 70 AND THE NATIONAL ELECTRICAL SAFETY

BURIED CABLING.

SEPARATION DISTANCE, DESCRIBED IN NOTE 3 SHALL APPLY BETWEEN CONDUITS AND DIRECT

4. WHERE DIRECT BURIAL CABLE(S) ARE PLACED IN SAME TRENCH WITH CONDUIT DUCT BANKS, (HORIZONTAL) IS AT LEAST 4" BETWEEN CABLES. TRENCH WIDTH WILL VARY.

ONLY) CAN BE INSTALLED AT THE SAME ELEVATION AS LONG AS MINIMUM SEPARATION DISTANCE

3. ALL DETAILS ARE SHOWN WITH ONE(1) CABLE PER SECTION. MULTIPLE CABLES (OF SAME TYPE

ON SHEETS ES-509 THROUGH ES-512 FOR EXACT QUANTITY OF CABLES.

SHEETS ES-601 THROUGH ES-603 AND PANEL SCHEDULES AND POWER AND DATA DIAGRAMS

2. THESE ARE TYPICAL LAYOUT DETAILS. REFER TO POWER AND DATA ONE-LINE DIAGRAMS ON

1. TRENCHES SHALL BE EXCAVATED. PLOWING IN OF CABLES IS NOT ACCEPTABLE.

EXCAVATED MATERIAL

BACKFILL USING

WARNING TAPE

PLASTIC UG RIBBON

SAND OR SCREENED FILL

LOW VOLTAGE POWER CABLES

12"

42"

6"

4"

EXCAVATED MATERIAL

BACKFILL USING

WARNING TAPE

PLASTIC UG RIBBON

SAND OR SCREENED FILL

FIBER OPTIC DATA CABLES

12"

42"

6"

4"

WARNING TAPE

PLASTIC UG RIBBON

6" LAYERS

COMPACT SOIL IN

DUCT (TYP)

4"SCHEDULE 80 PVC

SAND ENCASEMENT

ON EACH SIDE OF STREAM)

STREAM AND TO A POINT 10 FEET

SPECIFICATIONS (USE STONE BELOW

MATERIAL IN ACCORDANCE WITH

BACKFILL USING SATISFACTORY

MATCH EXISTING SURFACE.

AND OTHERWISE REPAIRED TO

SURFACE MUST BE CUT, PATCHED

12"

3"

7 1/2"

3"

7 1/2"

3"3"

SURFACE

REPAIRED TO MATCH EXISTING

PATCHED AND OTHERWISE

SURFACE MUST BE CUT,

IN 6" LAYERS

COMPACT SOIL

WITH SPECIFICATIONS

MATERIAL IN ACCORDANCE

BACKFILL USING SATISFACTORY

SIZE.

FOR CONDUIT AND WIRE

REFER TO SHEET ES-602

SCHEDULE 80 PVC DUCT.

SAND

WARNING TAPE

PLASTIC UG RIBBON

"12"

3"

3"

3"3"

EXCAVATED MATERIAL

BACKFILL USING

WARNING TAPE

PLASTIC UG RIBBON

SAND OR SCREENED FILL

CABLES

FIBER OPTIC DATA

LOW VOLTAGE POWER CABLES

(US/USL/UF)(USL/UF)

DIRECT BURIED DATA CABLES IN THE SAME TRENCH (US/UF)

LOW VOLTAGE DIRECT BURIED POWER CABLES AND FIBER OPTIC

12"

42"

6"

4"

4"

CABLES.

DETAIL FOR TYPE AND NUMBER OF

REFER TO SPECIFIED DUCT BANK

4500 PSI CONCRETE

WARNING TAPE

PLASTIC UG RIBBON

EXCAVATED MATERIAL

BACKFILL USING

12"

45"

3"

4"

4"

SURFACE

REPAIRED TO MATCH EXISTING

PATCHED AND OTHERWISE

SURFACE MUST BE CUT,

WARNING TAPE

PLASTIC UG RIBBON

IN 6" LAYERS

COMPACT SOIL

WITH SPECIFICATIONS

MATERIAL IN ACCORDANCE

BACKFILL USING SATISFACTORY

#4 REINFORCING RODS

4500 PSI CONCRETE

NUMBER OF DUCTS OR CABLES.

BANK DETAIL FOR TYPE AND

REFER TO SPECIFIED DUCT

3" 3"

3"

3"

"12"

OF 11,000 PSI.

MINIMUM COMPRESSIVE STRENGTH

WITH HEAVY-WEAVE FIBERGLASS.

POLYMER CONCRETE REINFORCED COEFICIENT OF FRICTION.

LOAD. 0.5 MINIMUM

21600 POUND PER SQUARE FOOT

HEAVY DUTY COVER RATED FOR

STEEL BOLTS

3/8 " STAINLESS

TYPE X Y Z

242412HH

NOMINAL DIMENSIONS (INCHES)

Z

X

Y

NO SCALE

DIRECT BURIED DETAIL 5

NO SCALE

DUCT BANK DETAIL -4 NO SCALEDUCT BANK DETAIL

NO SCALE

NO SCALE

CONCRETE ENCASED DUCT 8 NO SCALEHANDHOLE DETAIL

NO SCALE

FIBER OPTIC DIRECT BURIED 2 NO SCALELOW VOLTAGE DIRECT BURIED

E14

E14 E14

E14

E14 E14

E14

E14

44026-E14

E14

REFERENCE ONLY

D A

T E

S Y

M B

O L

R E

V

IS

IO

N S

B Y

DRAWN BY

APPROVED

DRAWING NUMBER SCALE

DATE

L&E NO:

NOTED

D. SAYLOR

K. CHAN

DIRECTORATEDIRECTORATE

OF PUBLIC WORKS

FORT BENNING, GEORGIA

CONCRETE ENCASED DIRECT

BURIED CABLES BANK / CABLE

DIRECTIONAL BORE

(US/USL)

POWER CABLES (US) (USL)DATA CABLES (UF)

BID DOCUMENTS

35% DESIGN

TYPICAL HANDHOLE & DIRECT BURIED DETAILS

FORT BENNING, GEORGIA

PISTOL QUALIFICATION COURSE RANGE

44026-E1
44026-E2
44026-E3
44026-E4
44026-E5
44026-E6
44026-E7
44026-E8
44026-E9
44026-E10
44026-E11
44026-E12
44026-E13
44026-E14

File details come from the government source that posted it.