This document outlines requirements for a federal contract opportunity to provide an eXportable Combat Training Capability (XCTC) system. The Army Contracting Command - Orlando intends to award a contract on behalf of the Army National Guard to enable brigade combat teams to conduct force-on-force and live-fire training exercises to assess mission essential task proficiency. Interested offerors are encouraged to submit any questions, comments or recommendations on the draft solicitation to the contract specialist by March 4, 2019 to help refine the final solicitation requirements. This pre-solicitation notice provides an opportunity for industry engagement but does not constitute a commitment to award a contract.
TDP Item 50 - FlexTrain System Communications Shelter Assembly Manual
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SETUPREQUIREMENTS:Quantitythreemen,1.5hours TEARDOWNREQUIREMENTS:Quantitythreemen,45mins EQUIPMENTREQUIREDforSetupandTeardown:
Quantitytwo:6+feetA-frameladders Quantityone:bubblelevel(bestif<4ftinlength) Quantitythree:leveragetool(multitoolorscrewdriverissufficient)topryoffthesnapsduring disassembly
ForFirst-timeinstallers:
SRI International FlexTrain System Communications Shelter Assembly Manual
G
H
I
J
K
L
46" Wall Panel 88" X 46" 1/2" 1 VC-Panel-Wall-46
Back Ceiling 93" X 46" 1/2" 1 VC-Panel-Ceiling-8
Panel
Front Ceiling 93" X 46" 1/2" 1 VC-Panel-Ceiling-8F-SRI
Panel
34" Wall Panel 88" X 34" 1 VC-Panel-Wall-34-SRI
Door Wall Panel 88" X 461/2" 1 VC-Panel-Wall-46D
6" Wall Panel 88" X 6" 1 VC-Panel-Wall-6-SRI
Roof Panel 94" X 46 1/4" 2 VC-Panel-Roof-8-SRI
NOTE:Thesepieceswereactually numberednotletterdesignatedwhenwe openedupthetransitcrate.Disregardthe lettersinthisdiagram.
Noneedtomeasurethisspacingyet.Floorpanelswilldoitforyou inalaterstep...
BackFloorPanelisidentifiablebythemarkerlabel"PatchPanel"onthewood-grainsurface, longedgeofthepanel.
Theslotsareevenlyspaced ontheBackFloorPanelwhile theFrontFloorPanelhasa uniqueslotorientationthat hastwoslotsclosetogether wheretheDOORwillbe.
Thisisanotherwaytoidentify BackfromFrontFloorPanel ifthemarkerlabelshavefaded.
PATCH
PANEL
closest markerlabelreads:
Levelthestructureandorientthefloorplanbasedonthemarkerlabelsonthefloor.Showninblueabove.
HVACDOOR
Note:thereare fourscrewholes andaholepassthru onthis20"panel.
Itishardtoseehere.
NOT
THE
DOOR.
Thisisthebackwallpanel.
WARNING:
Snapasyougoor thestructurewillfall down!!!
Inthepictureit doesn'tshowthatall theslotshavea snapyet..wrong.
Snapasmanyas youcanasyougo.
Makesuretocheckthelevel oftheflooragainhere.The shelterwillsettleaswallsare installed.
Noticethatthereareslots ontheexteriorface onallfoursidesof thisBackCeilingpanel.
Youwillneedtheladders forthisstep.Bestresults experiencedwithtwo guysontheladdershere andathirdguytoguidethe ceilingpaneldownthetrack insidetheshelter
Thethirdmanwillknow youhaveitrightwhen helooksuponinteriorface andseethat
REAR
CEILING
arrowpointtowardtheRear shelterwallwithPatch Panel
Youcannowsnap onalltheceiling panelslots EXCEPTforthe nearestsloton eachside.There willbewiggleroom togettheDoorside onlater.
Tryfeedingthe6"panelintotheseams fromthetop.Willrequireaguyona ladder.
Thisdrawingseems exaggerated.With thesnapsonmostof thestructureyouwill NOTseethismuch separation.However, therewillbeenough givetomakethelast seamfitbetween frontfaceandfront ceilingpanel.
Haveaguyontheinsideliftingup,andasecondguyonaladderreadytosliptheseaminplace.
Notethattherearenospareparts...eachpieceofhardwareisneededsobecarefulto accountforallwhenputtingashelterupandtearingitdown
GettingtheHVACunitoutofitsshippingboxis quiteachallenge.Pleasebepatientandtrynotto destroythebox.Thewoodisveryweak!
TryplacingtheHVACintoatruckbedandbackingituptotheshelter.Fromhereyoucanget twoguystoliftitfromtruckbedintoHVACmount.Itwillslideinnicely.
Thissquidcoveriswherethe50Ageneratorcablewillfeedintotheshelterandsupplythe powerdistributionboxwithpower.
Besuretotapeupandseal thepassthruholehere.
Itwasbuiltforfutureexpansion andwillbeunusedthissummer.
StrappingthebuildingisOPTIONAL.Itisuptotheteamtodetermineif theenvironmentalconditionswarrantstrapdownstopreventdestructioninwindstorms.
Theshelterhasbeentestedunanchoredat45MPHwinds.