Attachment_0010__STATISTICAL_PROCESS_CONTROL_(SPC)_TABLES.pdf

PDF 41 KB Posted

Attached to
60mm, 81mm, 120mm Mortar Propelling Charges
Solicitation number
W52P1J-16-R-0134
Issued by

About this file

Attachment 0010 STATISTICAL PROCESS CONTROL (SPC) TABLES

View the file

Other files

File Type Posted
Attachment_0031__MINIMUM_GUARANTEED_AMOUNT_FOR_60_81_120MM_MORTAR_PROPELLING_CHARGES.pdf PDF
Attachment_0032__SCHEDULE.pdf PDF
Solicitation_W52P1J-16-R-0134_Amendment_0005.pdf PDF
RFP_W52P1J-16-R-0134_Amendment_0004.pdf PDF
RFP_W52P1J-16-R-0134_Amendment_0003.pdf PDF
RFP_W52P1J-16-R-0134_Amendment_0002.pdf PDF
RFP_W52P1J-16-R-0134_Amendment_0001.pdf PDF
Attachment_0020__52.246-4520_DRAWING_NUMBER_LISTING.PDF PDF
Attachment_0019__52.246-4520_END_ITEM_COMPONENT_LISTING.PDF PDF
Attachment_0020__52.246-4520_DRAWING_NUMBER_LISTING.PDF PDF
Attachment_0019__52.246-4520_END_ITEM_COMPONENT_LISTING.PDF PDF
Request_for_Proposal_(RFP)_W52P1J-16-R-0134_Amendment_0001.pdf PDF
Attachment_0001__PRICE_MATRIX.xlsx XLSX spreadsheet
Attachment_0011__ASC_FORM_715-7_-_HAZARDOUS_MATERIAL_FORM.pdf PDF
Attachment_0021__RECOMMENDATION_FOR_CHARGE_ESTABLISHMENT_&_UNIFORMITY_CALCULATIONS.pdf PDF
Attachment_0008__DD1695_-_NOTICE_OF_REVISION_(NOR).pdf PDF
Attachment_0017__SECURITY_STATEMENT_OF_WORK_-_PHYSICAL_SECURITY_STANDARDS_FOR_DOD_SECURITY_RISK_CATEGORY_III_IV_AMMUNITION_AND_EXPLOSIVES_(A&E)_AT_COCO_FACILITIES.pdf PDF
Attachment_0013__GUIDANCE_ON_DOCUMENTATION_OF_CONTRACT_DATA_REQUIREMENTS_LIST_(CDRL).pdf PDF
Attachment_0012__INSTRUCTIONS_FOR_COMPLETING_FORM_1423.pdf PDF
Attachment_0005__ADDRESS_LIST.pdf PDF
Attachment_0020__52.246-4520_DRAWING_NUMBER_LISTING.pdf PDF
Exhibit_F__CONTRACT_DATA_REQUIREMENTS_LIST_(CDRL)_-_81MM_M220_PROPELLING_CHARGE.pdf PDF
Attachment_0009__U.S._GOVERNMENT_POINT_OF_CONTACT_LISTING.pdf PDF
Attachment_0003__OPSEC_AQUISITION_PLAN.pdf PDF
Exhibit_G__CONTRACT_DATA_REQUIREMENTS_LIST_(CDRL)_-_120MM_M234A1_PROPELLING_CHARGE.pdf PDF
Exhibit_E__CONTRACT_DATA_REQUIREMENTS_LIST_(CDRL)_-_81MM_M219_PROPELLING_CHARGE.pdf PDF
Attachment_0019__52.246-4520_END_ITEM_COMPONENT_LISTING.pdf PDF
RFP_W52P1J-16-R-0134.pdf PDF
Exhibit_B__CONTRACT_DATA_REQUIREMENTS_LIST_(CDRL)_-_60MM_M235_PROPELLING_CHARGE.pdf PDF
Exhibit_D__CONTRACT_DATA_REQUIREMENTS_LIST_(CDRL)_-_81MM_M218_PROPELLING_CHARGE.pdf PDF
Attachment_0007__DD1694_-_REQUEST_FOR_VARIANCE_(RFV).pdf PDF
Attachment_0018__STATEMENT_OF_WORK_FOR_INERT_PROPELLING_CHARGES.pdf PDF
Attachment_0002__PAST_PERFORMANCE_QUESTIONNAIRE.docx DOCX document
Attachment_0006__DD1692_-_ENGINEERING_CHANGE_PROPOSAL_(ECP).pdf PDF
Exhibit_C__CONTRACT_DATA_REQUIREMENTS_LIST_(CDRL)_-_60MM_M236_PROPELLING_CHARGE.pdf PDF
Exhibit_A__CONTRACT_DATA_REQUIREMENTS_LIST_(CDRL)_-_60MM_M204_PROPELLING_CHARGE.pdf PDF
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Rock Island Statistical Process Control (SPC) Requirements

The contractor shall consider the below SPC requirements as well as any additional SPC when establishing his bid for this solicitation. At a minimum the following characteristics shall be subjected to the application of SPC techniques as identified:

Paragraph

4.4.2.1 Examination or Test

Type of Charting

Critical 1 Weight of propellant in excess of 3 grains below min or above max. X Bar R Critical 2 Gross weight of propelling charge, min. X Bar R

101 Weight of propellant from min. to and including 3 grains below min. X Bar R 102 Weight of propellant from max to and including 3 grains above max. X Bar R 103 Gross weight of propelling charge, max. X Bar R

Note 1* Tabbing process

Note 1: The contractor to provide a description of the process control procedures including the monitoring and charting of applicable parameters.

Revised 27 FEB 2017

60MM Drawing # 9312698/12982841/13008610 Characteristics for SPC Control Charting – MIL-DTL-32276

Attachment 0010 when establishing his bid for this solicitation. At a minimum the following characteristics shall be subjected to the application of SPC techniques as identified:

Paragraph 4.4.2.1

Examination or Test

Type of Charting

Critical 1 Weight of propellant in excess of 10 grains below min or above max. X Bar R Critical 2 Gross weight of propelling charge, min. X Bar R

101 Weight of propellant from min. to and including 10 grains below min.

X Bar R

102 Weight of propellant from max. to and including 10 grains above max.

X Bar R

103 Gross weight of propellant charge, max. X Bar R Note 1* Tabbing process

Note 1: The contractor to provide a description of the process control procedures including the monitoring and charting of applicable parameters.

Revised 27 FEB 2017

81MM Drawing # 9300234/9378134/9381510 Characteristics for SPC Control Charting – MIL-DTL-70545A when establishing his bid for this solicitation. At a minimum the following characteristics shall be subjected to the application of SPC techniques as identified:

Paragraph 4.4.2.1

Examination or Test

Type of Charting

Critical 1 Weight of propellant in excess of 3.0 grams below min. X Bar R Critical 2 Gross weight of propelling charge, 3.3 grams below min X Bar R

101 Weight of propellant from min. to and including 3.0 grams below min.

X Bar R

102 Weight of propellant, max. X Bar R 105 Gross weight of propelling charge X Bar R

Note 1* Tabbing process

Note 1: The contractor to provide a description of the process control procedures including the monitoring and charting of applicable parameters.

Revised 27 FEB 2017

120MM Drawing # 12577282/12977375/13038372 Characteristics for SPC Control Charting – DTL12977282