F35-ADAL B404 Addendum 1.doc
DOC document 96 KB Posted
- Attached to
- F-35 ADD/ALTER SQUADRON OPERATIONS 404 Federal contract opportunity
- Solicitation number
- W50S9F-21-R-0001
- Issued by
- Department of the Army National Guard
About this file
This federal solicitation requests proposals for construction services to alter and add to an F-35 Squadron Operations building at Truax Field Air National Guard Base in Madison, Wisconsin. The project includes renovating approximately 4,300 square feet of existing space for new F-35 functions and upgrading existing vault space. Additional construction includes 300 square feet for a Sensitive Compartmented Information Facility and 1,000 square feet for a Pilot Extraction Simulator Training area. Work involves minor demolition, new construction, and modifications to mechanical, plumbing, electrical, and technology systems. Proposals are due January 20, 2021 with award by the Department of the Army National Guard. The contract duration is 365 days with a value between $1-5 million. The North American Industry Classification code is 236220 and small businesses are encouraged to compete.
View the file
Other files for this federal contract opportunity
Show all 45
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project name:
| F-35: ADAL Building 404 |
| Client: |
| Truax Field ANGB |
| Project location: |
| Madison, WI |
| Client representative: |
| MSgt Kate Fox |
| Project number: |
| XGFG182010 |
| Date: |
| January 15, 2021 |
TO ALL BIDDERS: You are requested to make all changes and/or additions contained in this Addendum to the Bidding Documents. Failure to acknowledge this Addendum in Proposal shall result in rejection of bid.
I.
DRAWINGS
A. Drawing A-601:
a. DOOR AND HARDWARE SCHEDULE
i. Change the Frame Type from F1 to F3 for the following openings: 112, 114, 125A, 175.
B. Drawing E-601:
a. LUMINAIRE SCHEDULE
i. Change the fixture description for fixture type D1 as follows: 6" DIAMETER DOWNLIGHT WITH SOFT SATIN GLOW, CLEAR REFLECTOR FINISH; WHITE FLANGE FINISH; 70 DEGREE BEAM ANGLE.
II.
SPECIFICATIONS
A.
Section 033000 Cast-In-Place Concrete:
a.
Revise paragraph 2.3.3.1.d to read:
“Submit types, pit or quarry locations, producers' names, aggregate supplier statement of compliance with ASTM C33. Additionally, submit alkali-silica reaction results that comply with either of the following: (1) Expansion Result of Aggregate: Not more than 0.04 percent at one-year when tested in accordance with ASTM C1293 or (2) Expansion Results of Aggregate and Cementitious Materials in Combination: Not more than 0.10 percent at an age of 16 days when tested in accordance with ASTM C1567.”
B.
Section 083323-Overhead Coiling Doors:
a.
Delete section in its entirety.
END OF ADDENDUM