ATTACHMENT 03 DRAWINGS Project No.XGFG182010 dated 31Jul2020.pdf

PDF 32 MB Posted

Attached to
F-35 ADD/ALTER SQUADRON OPERATIONS 404 Federal contract opportunity
Solicitation number
W50S9F-21-R-0001
Issued by
Department of the Army National Guard

About this file

This solicitation is for a firm fixed-price construction contract to alter and add to an F-35 Squadron Operations facility at Dane County Regional Airport in Madison, Wisconsin. The project seeks to reconfigure existing space for F-35 Autonomic Logistics Information System functions and optimization of the Human Weapon System, upgrade existing vault walls to meet security standards, and construct additional secure areas for operations and pilot training. Work includes minor demolition, construction, and modifications to mechanical, plumbing, electrical, and technology systems. The contract duration is 365 days from notice to proceed, with an estimated value between $1 million and $5 million. The solicitation closing date is January 20, 2021. Evaluation criteria are technical approach, past performance, and price. The intent is to award without discussions to the responsible offeror providing the best value. The North American Industry Classification code is 236220 and size standard is $39.5 million. The solicitation and plans are available at beta.SAM.gov.

View the file

Other files for this federal contract opportunity

Other files attached to F-35 ADD/ALTER SQUADRON OPERATIONS 404, newest first.
File Type Posted
08 71 00A Hardware Sets Schedule B404_Add02.pdf PDF
08 11 13_Add02.pdf PDF
W50S9F21R00010004.pdf PDF
08 71 00_Add02.pdf PDF
F35-ADAL B404 Addendum 2.doc DOC document
F35-ADAL B404 Addendum 1.doc DOC document
Question and Answer 07.docx DOCX document
W50S9F21R00010003.pdf PDF
XGFG182010 F-35 ADAL B404 Type B3 Drawings (G-011 Revised).pdf PDF
Question and Answer 06.docx DOCX document
W50S9F21R00010002.pdf PDF
EXHIBIT H PROPOSAL PRICE SCHEDULE V2.docx DOCX document
Question and Answer 05.docx DOCX document
B404 Walk-Through Photos.pdf PDF
Question and Answer 04.docx DOCX document
Question and Answer 03.docx DOCX document
Question and Answer 02.docx DOCX document
Geotechnical Report.pdf PDF
Question and Answer 01.docx DOCX document
Pre-Proposal Slides - F-35 B404.pptx PPTX presentation
Pre-Proposal Attendance Sheet.pdf PDF
W50S9F21R0001.pdf PDF
EXHIBIT D LETTER OF COMMITMENT.docx DOCX document
ATTACHMENT 09 SAP SINGLE SOURCE DETERMINATION HALLMAN LINDSEY.pdf PDF
EXHIBIT G SMALL BUSINGESS SUBCONTRACTING PLAN FORMAT.docx DOCX document
ATTACHMENT 11 SAP SINGLE SOURCE DETERMINATION KRIEGER.pdf PDF
ATTACHMENT 16 SFS FORM 12.xls XLS spreadsheet
EXHIBIT A PERFORMANCE RELEVANCY QUESTIONNAIRE AND SPECIALIZED COMPANY EXPERIENCE.docx DOCX document
EXHIBIT B SUBCONTRACTOR TEAM KEY PERSONNEL INFORMATION AND CONSENT FORM.doc DOC document
EXHIBIT H PROPOSAL PRICE SCHEDULE.docx DOCX document
W50S9F21R0001.pdf PDF
ATTACHMENT 01 PLANS AND SPECIFICATIONS Vol 1 of 2 Project No.XGFG182010 dated 31Jul2020.pdf PDF
ATTACHMENT 02 PLANS AND SPECIFICATIONS Vol 2 of 2 Project No.XGFG182010 dated 31Jul2020.pdf PDF
ATTACHMENT 04 AFE PILOT LOCKER DRAWINGS Project No.XGFG182010 dated 20Jul2020.pdf PDF
ATTACHMENT 07 SAP SINGLE SOURCE DETERMINATION ARMSTRONG.pdf PDF
ATTACHMENT 13 SAP SINGLE SOURCE DETERMINATION MILLIKEN.pdf PDF
ATTACHMENT 14 SAP SINGLE SOURCE DETERMINATION VENDURA.pdf PDF
ATTACHMENT 15 PRE PROPOSAL SITE VISIT INSTRUCTIONS.docx DOCX document
EXHIBIT F SMALL BUSINESS PARTICIPATION PLAN FORMAT.docx DOCX document
ATTACHMENT 06 SAP SINGLE SOURCE DETERMINATION ANDOVER.pdf PDF
ATTACHMENT 08 SAP SINGLE SOURCE DETERMINATION ATI.pdf PDF
ATTACHMENT 10 SAP SINGLE SOURCE DETERMINATION JOHNSONITE.pdf PDF
ATTACHMENT 12 SAP SINGLE SOURCE DETERMINATION MARSHALL BEST.pdf PDF
EXHIBIT C PAST PERFORMANCE REFERENCE QUESTIONNAIRE.docx DOCX document
ATTACHMENT 05 SAP SINGLE SOURCE DETERMINATION ADVANTOR.pdf PDF
Show all 45

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T

P

RED

W H

IT

E

YE

LL

O W

W H

IT

E

YE

LL

O W

W H

IT

E

W H

IT

E

YE

LL

O W

W H

IT

E

W H

IT

E

W H

IT

E

RED

STATE MAP:

STATE OF WISCONSIN

CITY OF MADISON,

DANE COUNTY

VICINITY MAP:

PROJECT LOCATION

TRUAX BASE MAP:

SOUTH RAMP

TAXIW

AY "D"

T A

X

IW

A Y

B

TAXIWAY "F" MILLER ST.

MITCHELL ST.

PIERSTORFF ST.

MAIN GATE/

ENTRY

T A

X

IW

A Y

G

BASE CIVIL

ENGINEERING

OFFICE (B1210)

PROJECT SITE

(B404)

CONSTRUCTION

HAUL ROUTE

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

/4

/2

:5

:1

P M

C

R e v it L o c a l\

-1

.0 -A

-C e n tr a l-s z k .r v t

ANG NO.: XGFG182010

F-35: ADAL BUILDING 404

MADISON, WI

TRUAX FIELD ANGB

T R

U A

X F

IE

L D

A N

G B

M A

D

IS

O N

W

I

F -3

A D

A L B

U

IL

D

IN

G

G-001

COVER SHEET

XGFG182010ANG NO.:

3141300-190289.02

KLU

JJB

JULY 31, 2020

SZK

ELECTRICAL

E-001 NOTES, SYMBOLS & ABBREVIATIONS

ED101 FIRST FLOOR DEMOLITION PLAN - POWER

ED121 FIRST FLOOR DEMOLITION PLAN - LIGHTING

E-101 FIRST FLOOR PLAN - POWER

E-121 FIRST FLOOR PLAN - LIGHTING

E-122 FIRST FLOOR ABOVE CEILING PLANS - LIGHTING

E-131 ROOF PLAN - LIGHTNING PROTECTION

E-401 ENLARGED PLANS

E-501 DETAILS

E-502 DETAILS

E-601 SCHEDULES

E-602 SCHEDULES

E-701 ONE-LINE DIAGRAMS

TECHNOLOGY SYSTEMS

T-001 NOTES, SYMBOLS & ABBREVIATIONS

TD101 FIRST FLOOR DEMOLITION PLAN - TECHNOLOGY

T-101 FIRST FLOOR PLAN - COMMUNICATIONS

T-131 FIRST FLOOR PLAN - SECURITY

T-161 FIRST FLOOR PLAN - AUDIO/VISUAL

T-401 ENLARGED PLANS - ROOM 107

T-402 ENLARGED PLANS - ROOM 171

T-403 ENLARGED PLANS - ROOM 112A

T-404 ENLARGED PLANS - ROOM 126

T-501 DETAILS

T-701 ONE-LINE DIAGRAMS

T-601 SCHEDULES

FIRE PROTECTION

F-001 FIRE PROTECTION LEGEND, NOTES AND

ABBREVIATIONS

F-102 FIRE PROTECTION HAZARD CLASSIFICATION PLAN

F-103 FIRE ALARM PLAN

F-501 FIRE PROTECTION DETAILS

F-502 FIRE ALARM DETAILS

F-602 FIRE ALARM FUNCTIONAL MATRIX

F-603 FIRE ALARM SYSTEM RISER DIAGRAM

PLUMBING

P-001 PLUMBING NOTES & SYMBOLS

P-100 UNDERGROUND DRAIN AND VENT PLUMBING PLAN

P-101 FIRST FLOOR - DRAIN AND VENT PLUMBING PLAN

P-131 FIRST FLOOR - SUPPLY PLUMBING PLAN

P-901 DRAIN AND VENT ISOMETRIC PLAN

P-931 SUPPLY ISOMETRIC PLAN

MECHANICAL

M-001 MECHANICAL NOTES & SYMBOLS

MD101 HVAC DEMOLITION FLOOR PLAN

MD102 HVAC DEMOLITION ROOF PLAN

MD131 MECHANICAL DEMOLITION FLOOR PLAN

M-101 HVAC FLOOR PLAN

M-102 HVAC ROOF PLAN

M-131 MECHANICAL FLOOR PLAN

M-501 MECHANICAL DETAILS

M-511 MECHANICAL DETAILS

M-601 MECHANICAL SCHEDULES

M-611 MECHANICAL SCHEDULES

M-801 CONTROL SCHEMATICS

GENERAL

G-001 COVER SHEET

G-011 OPERATIONS PLAN AND TEMPORARY FACILITIES

G-101 CODE ANALYSIS PLAN

G-102 SECURITY ZONE DIAGRAM PLAN

CIVIL

C-021 EXISTING SITE PLAN

C-041 SITE DEMOLITION PLAN

C-101 SITE IMPROVEMENTS PLAN

C-102 CONCRETE JOINTING PLAN

C-121 SITE GRADING AND EROSION CONTROL PLAN

C-141 SITE UTILITIES PLAN

C-151 CODE COMPLIANCE SITE PLAN

C-501 DETAILS

C-502 DETAILS

C-503 DETAILS

STRUCTURAL

S-001 STRUCTURAL NOTES

S-005 SPECIAL INSPECTIONS SCHEDULES AND NOTES

S-010 STRUCTURAL LOADING PLAN

S-101 FOUNDATION PLAN

S-111 FLATWORK PLAN

S-121 STRUCTURAL WALL PLAN

S-151 LOW ROOF FRAMING PLAN

S-152 INTERMEDIATE ROOF FRAMING PLAN

S-501 FOUNDATION DETAILS

S-511 FLATWORK DETAILS

S-521 STRUCTURAL WALL DETAILS

S-541 FRAMING DETAILS

S-551 FRAMING DETAILS

ARCHITECTURAL

A-001 NOTES & SYMBOLS

A-002 PARTITION TYPES

AD101 DEMOLITION PLANS

A-101 FIRST FLOOR PLAN

A-102 ROOF PLAN

A-121 FIRST FLOOR REFLECTED CEILING PLAN

A-201 EXTERIOR ELEVATIONS

A-301 BUILDING SECTIONS

A-501 DETAILS

A-601 DOOR & HARDWARE SCHEDULE

A-621 DOOR & WINDOW DETAILS

A-801 SIGNAGE

A-901 FURNITURE PLAN - FOR REFERENCE ONLY

SHEET INDEX

NO SCALE

3D VIEW- SOUTHWEST CORNER

07/31/20 TYPE B3 FINAL

0.106

B406

B404

B410

B402

OPERATIONS

0.102

CONSTRUCTION

PERIMETER

FENCE

DO NOT CROSS RED LINE

TEMP. USE

TEMP.

USE

ECP

x x x x x

ROOM 126

EXISTING

TRANSFORMER

EXISTING

TRANSFORMER

B400

B401

B409

T4

T3

T2

B503

B307

B305

T1

0.106

0.106

0.101

0.103

0.104

0.101

0.104

0.105

0.105

HOSE

BIB

0.106

00 30 60

G-011

OPERATIONS PLAN

AND TEMPORARY

FACILITIES

JJB

NJD

JJB

RESTRICTED AREAS/SAFTEY AREAS:

1. RUNWAYS, TAXIWAYS, AND APRON: CONSTRUCTION ACTIVITY ADJACENT TO THE RUNWAYS,

TAXIWAYS, AND APRONS WHICH WILL BE IN USE SHALL BE COORDINATED WITH AIRPORT

OPERATIONS THROUGH THE COR. CONSTRUCTION ACTIVITY WILL BE AUTHORIZED AFTER

NOTAMS (NOTICES TO AIRMEN) HAVE BEEN ISSUED BY THE AIRPORT (DCRA); AND AFTER IT HAS

BEEN DETERMINED THAT THE HEIGHT OF EQUIPMENT AND MATERIALS IS BEYOND THE REACH OF

THE AIRCRAFT OR SAFELY BELOW ANY PART OF THE AIRCRAFT USING THE OPERATIONS AREAS

WHICH MIGHT OVERHANG THESE AREAS. INFORMATION FOR RUNWAY APPROACHES AND OTHER

AREAS WILL BE SUPPLIED BY THE C.O.R. IF IT IS REQUIRED.

2. EXCEPT AS PROVIDED ON THE CONTRACT PLANS OR IN CONTRACT SPECIAL PROVISIONS OR AS

MAY BE AUTHORIZED BY THE C.O.R. IN WRITING, THE CONTRACTOR SHALL PERFORM

CONSTRUCTION ACTIVITIES WITHIN 80 FEET OF THE EDGE OF AN ACTIVE TAXIWAY OR APRON, WITHIN 250 FEET OF AN ACTIVE RUNWAY CENTERLINE, OR WITHIN 1000 FEET OF A RUNWAY END.

WHEN SO AUTHORIZED TO PERFORM CONSTRUCTION ACTIVITIES WITHIN SUCH AREAS, THE

CONTRACTOR SHALL FIRST IMPLEMENT APPROPRIATE MARKING AND LIGHTING PROVISIONS.

3. EXCAVATION AND OPEN TRENCHES LOCATED WITHIN 250 FEET FROM THE CENTERLINE OF AN

ACTIVE RUNWAY SHALL BE ADEQUATELY SIGNED, MARKED AND LIGHTED. EXCAVATIONS AND

OPEN TRENCHES LOCATED ADJACENT TO TAXIWAY AND APRON PAVEMENT SHALL BE

ADEQUATELY SIGNED, MARKED AND LIGHTED.

4. DEBRIS SHALL NOT BE DEPOSITED ON ANY PORTION OF AN OPERATIONAL RUNWAY, TAXIWAY, OR

APRON. SHOULD ANY DEBRIS BE DEPOSITED ACCIDENTALLY, IT SHALL BE REMOVED

IMMEDIATELY.

5. OPEN-FLAME WELDING OR TORCH-CUTTING OPERATIONS ARE PROHIBITED UNLESS ADEQUATE

FIRE AND SAFETY PRECAUTIONS ARE PROVIDED AND HAVE BEEN APPROVED BY THE TRUAX FIRE

DEPT. ALL VEHICLES ARE TO BE PARKED AND SERVICED BEHIND THE CONSTRUCTION

RESTRICTION LINE 750 FEET OR MORE FROM AN ACTIVE RUNWAY CENTERLINE OR 200 FEET FROM

AN ACTIVE TAXIWAY CENTERLINE.

6. MATERIALS SHALL BE STORED WITHIN THE FENCE PERIMETER OR THE BUILDING ITSELF.

MATERIALS SHALL BE SUBJECT TO RANDOM INSPECTIONS BY SECURITY FORCES.

MARKING AND LIGHTING:

1. EXCAVATION/STOCKPILES-EXCAVATION ADJACENT TO PAVED SURFACES MUST BE

APPROPRIATELY MARKED BY BARRICADES.

2. CONTRACTOR SHALL BARRICADE OPEN EXCAVATIONS AS REQUIRED BY THE C.O.R.

FUEL SUPPORT:

1. ANY TYPE OF FUELING SUPPORT FACILITY OR DEVICE USED TO REFUEL CONSTRUCTION

EQUIPMENT IS SUBJECT TO WANG FIRE INSPECTION. LOCAL FIRE CODES AND SAFETY

STANDARDS SHALL BE MET PRIOR TO COMMENCEMENT OF WORK.

SWEEPING/CLEAN-UP:

1. THE CONTRACTOR SHALL HAVE SWEEPING OR VACUUMING CAPABILITIES ON-SITE AT ALL TIMES

IN ORDER TO REMOVE DEBRIS AS IT OCCURS. UPON COMPLETION, THE CONTRACTOR IS

RESPONSIBLE FOR INSURING THAT THE AREA OF CONCERN IS RETURNED TO ITS ORIGINAL

CONDITION.

HAUL ROUTES:

1. HAUL ROUTES AND ACCESS TO THE CONSTRUCTION SITES WILL BE DISCUSSED AT THE PRE-BID

CONFERENCE AND ARE DEPICTED ON G-001.

2. THE CONTRACTOR SHALL CONDUCT HIS OPERATIONS ON THE BASE IN A MANNER THAT WILL

MINIMIZE INTERFERENCE WITH THE NORMAL OPERATIONS OF AIRPORT FACILITIES THAT ARE TO

REMAIN OPEN TO AIR TRAFFIC, AND THE CONTRACTOR SHALL IMPLEMENT ALL SPECIFIED AND

OTHER APPROPRIATE MEASURES TO ENSURE THE SAFETY OF ALL USERS OF THE AIRPORT.

3. THE CONTRACTOR SHALL ALSO ABIDE BY ALL WANG REQUIREMENTS CONTAINED WITHIN THE

SPECIFICATIONS.

4. CONTRACTOR SHALL NOT USE RADIO EQUIPMENT OR CELL PHONES WITHIN 400 FEET OF

AIRCRAFT.

ENFORCEMENT:

1. VIOLATION OF THESE RULES AND REGULATIONS, DEPENDING UPON

SEVERITY OF THE VIOLATION, MAY RESULT IN ONE OR MORE OF THE

FOLLOWING:

1.1. A VERBAL AND/OR WRITTEN WARNING.

1.2. REVOCATION OF AOA BADGE AND/OR VEHICLE ACCESS PERMIT.

1.3. THE CONTRACT WORK BEING STOPPED UNTIL CORRECTIVE

MEASURES ARE TAKEN TO PRECLUDE A RECURRENCE OF THE

VIOLATION.

2. CONTRACTOR SHALL ALSO ABIDE BY ALL WANG REQUIREMENTS

CONTAINED WITHIN THE SPECIFICATION.

KEYED NOTES:

X.XXX

0.101 MAINTAIN CLEAR DRIVE AND GATE, TYP.

0.102 TEMPORARY FACILITY DOUBLE WIDE TRAILER 24'-0" x 60'-0" - SEE

NOTES FOR TRAILER LAYOUT AND AMENITIES. REF CONTRACTING OFFICER

REPRESENTATIVE REGARDING FINAL LAYOUT.

0.103 PROVIDE TEMPORARY POWER TO TRAILERS FOR DURATION OF

CONSTRUCTION. PROVIDE A 100 AMP 120/240V SINGLE PHASE FEEDER TO

EACH TRAILER. CONTRACTOR SHALL FIELD VERIFY AND COORDINATE

SOURCE OF POWER. POWER MAY BE SUPPLIED BY A TEMPORARY UTILITY

SERVICE (WE ENERGIES), OR BY BUILDING ELECTRICAL DISTRIBUTION.

PROVIDE ALL NECESSARY FEEDER BREAKERS, CABLING, AND SUPPORT AS

NECESSARY. REMOVE TEMPORARY POWER AT END OF CONSTRUCTION.

0.104 PROVIDE TEMPORARY NETWORK COMMUNICATIONS TO TRAILERS FOR

DURATION OF CONSTRUCTION. PROVIDE TWO DUPLEX SINGLE MODE LC/UPC

FIBER CABLES AND A 25 PAIR CAT5 CABLE FROM ROOM 126 IN B402, THROUGH

THE ATTIC, EXITING THE WEST SIDE OF THE BUILDING.

0.105 PROVIDE 8' HIGH PORTABLE CHAIN LINK FENCING FOR SECURE TRAILER

SURROUNDING THE DOUBLE WIDE TRAILER. CONNECT TO EXISTING ACA

FENCE. FENCE POSTS MUST BOLT TO PAVEMENT. SEE SPECIFICATION 015100

FOR FENCE REQUIREMENTS.

0.106 MAINTAIN 15'-0" CLEAR, TYP.

"OPERATIONAL SAFETY ON AIRPORTS DURING CONSTRUCTION":

CONFORMS TO AC150/5370-2E

1. CONTRACTOR SHALL REMOVE FENCE AND PATCH PAVEMENT AND LANDSCAPING

DAMAGED FROM TRAILERS AND FENCING DURING PROJECT.

2. BUILDING 404 SHALL BE OCCUPIED THROUGHOUT CONSTRUCTION. ONLY THE SECURE

AREA WILL BE ABANDONED. CONSTRUCTION SHALL BE SEQUENCED TO MINIMIZE

DOWNTIME FOR THE SECURE AREA. COORDINATE WITH THE COR AND BUILDING

OCCUPANTS FOR ANY BUILDING DOWNTIME OR DISRUPTIONS. PROVIDE SECURED

PROTECTION (WOOD FRAMING AND PLASTIC SHEATHING) FROM CONSTRUCTION AREA

TO PREVENT DEBRIS FROM PENETRATING OCCUPIED AREAS.

GENERAL NOTES:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

SHEET NO.

© Copyright 2020

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

Mead & Hunt, Inc.

ANG NO.:

07/31/2020 TYPE B3 FINAL

JULY 31, 2020

T R

U A

X

F

I E

L D

A

N G

B

F

A

L T

E R

B

U I L

D I N

G

M A

D I S

O N

W

I

TRAILER LAYOUT & AMENITIES

1. PROVIDE TWO OFFICES ON EACH END, FOUR OFFICES TOTAL.

2. CONSTRUCTED WITH NO WINDOWS. IF WINDOWS ARE INTEGRAL, THEY

MUST BE BLOCKED FROM THE INSIDE WITH DRYWALL, FILLED WITH

INSULATION, AND THE EXTERIOR COVERED WITH PLYWOOD.

3. PROVIDE WOOD STAIR WITH 6'x6' LANDING AT PRIMARY ENTRY.

4. COVER MAIN ENTRY AND LANDING WITH AN AWNING.

5. SECONDARY ENTRY MAY UTILIZE A STANDARD DEMOUNTABLE STAIR.

6. PROVIDE EXTERIOR LIGHTING FOR SECURITY (ALL SIDES).

7. PROVIDE HEATING AND AIR CONDITIONING.

8. DOORS MUST BE KEY LOCKED.

9. INCLUDE SKIRTING FOR ELEVATED FACILITIES.

10. PROVIDE A CURTAIN AND TRACK AROUND ENTRY DOORS TO PREVENT

OPEN VIEWING INTO THE TRAILER WHEN THE DOOR IS OPENED.

F.E.

F.E.

REF.

D W

DW

ID-01ID-01

CODE PLAN LEGEND:

OCCUPANT LOAD

(OR MAX. CAPACITY)6

XX"

XX"

OCCUPANT LOAD FACTOR

REQ'D WIDTH

PROVIDED WIDTH

EXIT DISCHARGE

1 HR RATED WALL

F.E. FIRE EXTINGUISHER -

WALL MOUNTED

F.E.C. FIRE

EXTINGUISHER -

CABINET

AREA EXIT

EXIT PATHWAYS

13' - 4"

2.2"

72"

10' - 0"

31' - 1"7' - 9"

4' - 6"

20' - 0"

24' - 3"

24' - 7"

33' - 10" 33' - 1"

15' - 9"

11' - 1"

11' - 6"

26' - 11"

11' - 4"

39' - 7"

11' - 6"

11.2"

36"

10.8"

36"

11.2"

36"

11.4"

36"

11.2"

36"

11.4"

72"

FEC

FEC

FEC

FEC

FECAED

7.2"

36"

7.2"

36"

7.4"

36"

10' - 4"

18' - 3" 3' - 2"42' - 6"

36' - 8"

30' - 8"

20' - 10"

3.4

72"

11' - 1"

23' - 7"

FEC

WORK AREA 'A'

WORK AREA 'B'

WORK AREA 'C'

WORK AREA 'C'

CLASSROOM

ISSO/ SSM

OFFICE

112A

SERVER

ROOM

INTEL NCOIC

INTEL OIC

111A

BRIEFING

ROOM 5

INTEL

BRIEFING

ROOM 3

BRIEFING

ROOM 4

LIBRARY

STORAGE

BREAK ROOM

BRIEFING

ROOM 2

BRIEFING

ROOM 1

HALLWAY

MISSION

PLANNING

ISSO/ISSM

OFFICE

WEAPONS

COMM/

COMPUTER

STORAGE

MX DEBRIEF

SECURED

VEST

PM/GSSO

OPEN OFFICE

124B

FIRE ALARM

124A

ELEC

HALL

ALIS ADMIN

OFFICE

ALIS

SERVERS

OHWS 129

OFFICE

FLIGHT

COMMANDERS

STORAGE

TRAINING

OFFICER

SCHEDULING

HALLWAY

ARMS

ARMS NCOIC

VEST

SOF

VEST

AFMT NCOIC

AIRFIELD

MANAGEMENT

DIRECTOR OF

OPERATIONS

FIGHTER

SQUADRON

COMMANDER

OPERATIONS

GROUP

COMMANDER

VEST

HALLWAY

HALLWAY

CONFERENCE

ROOM

STAN EVAL 152

OPERATIONS

CHIEF

CCA

OSS

COMMANDER

CLASS ROOM

PEST

MEN'S

TOILET/

LOCKER

ROOM

AIRCREW

FLIGHT

EQUIPMENT

AFE NCOIC

NVG

AFE

SUPERINTENDENT,

FEO

WOMENS

ENTRY

WOMEN'S

TOILET/

LOCKER

ROOM

AFE

INSPECTION

ROOM

AFE WORK

ROOM

ELEC

COMM

MECH

BREAK ROOM

MAIN

BRIEFING

ROOM

LOBBY

HALLWAY

VEST

WORK AREA 'B'

WORK AREA 'A'

JANITOR

STORAGE

166A

STORAGE

166C

STORAGE

HALLWAY

VEST

KITCHEN/

VENDING

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

/4

/2

:5

:2

P M

C

R e v it L o c a l\

-1

.0 -A

-C e n tr a l-s z k .r v t

T R

U A

X F

IE

L D

A N

G B

M A

D

IS

O N

W

I

F -3

A D

A L B

U

IL

D

IN

G

G-101

CODE ANALYSIS

PLAN

XGFG182010ANG NO.:

3141300-190289.02

KLU

JJB

JULY 31, 2020

SZK

PLAN

NORTH

TRUE

NORTH

3/32" = 1'-0"1

CODE ANALYSIS PLAN

07/31/20 TYPE B3 FINAL

ASHRAE Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings - 2010

ASHRAE Standard 62.1: Ventilation for Acceptable Indoor Air Quality - 2010

ASHRAE Standard 55: Thermal Environmental Conditions for Human Occupancy - 2010

Mechanical/HVAC:

NFPA 170: Standard for Fire Safety and Emergency Symbols - 2018

NFPA 101: Life Safety Code - 2018

NFPA 90A: Standard for the Installation of Air Conditioning and Ventilating Systems - 2018

NFPA 75: Standard for Fire Protection of Information Technology Equipment - 2016

NFPA 72: National Fire Alarm Code and Signaling Code - 2019 NFPA 70: National Electrical Code - 2020

NFPA 24: Standard for the Installation of Private Service Mains and Their Appurtenances

- 2019

NFPA 13: Standard for the Installation of Sprinkler Systems - 2019

NFPA 1: Fire Code - 2018

Fire/Life Safety Code:

IBC, Chapter 34 and the International Existing Building Code (IEBC)

IBC v2018 as modified by Chapters 2 and 3 of UFC 1-200-01 in which certain sections of the IBC shall be superseded by UFC 3-600-01 and referenced public code NFPA 101

Public Codes:

● Applicable current ANG-ETL's as listed in ANG-ETL 15-01

ANG-ETL 15-01, Air National Guard Design Policy - May 1, 2015

Air National Guard Engineering Technical Letters (ANG-ETL)

Air National Guard Design Requirements:

Accessibility: Architectural Barriers Act (ABA) Standards (2015)

Energy Conservation: Public Law 1095-58; Energy Policy Act (EPAct of 2005),

- August 8, 2005

Public Law:

UFC 4-021-01: Design and O&M: Mass Notification Systems - Change 1, January 2010

UFC 4-010-05: Sensitive Compartmented Information Facilities

- Change 4, September 28, 2017

UFC 4-010-01: DoD Minimum Antiterrorism Standards for Buildings - December 12, 2018

UFC 3-600-01: Fire Protection Engineering for Facilities - Change 4, February 2020

UFC 3-580-01: Telecommunications Building Cabling Systems Planning and Design

- June 1, 2016

UFC 3-560-01: Electrical Safety, O&M - Change 1, February 21, 2019

UFC 3-550-01: Exterior Electrical Power Distribution - Change 2, March 13, 2019

UFC 3-530-01: Interior and Exterior Lighting Systems and Controls

- Change 3, June 1, 2016

UFC 3-520-01: Interior Electrical Systems - Change 1, March 20, 2019

UFC 3-501-01: Electrical Engineering - October 6, 2015 UFC 3-430-01FA: Heating and Cooling Distribution Systems - July 25, 2003

UFC 3-420-01: Plumbing Systems - Change 10, October 26, 2015

UFC 3-410-01: Heating, Ventilating, and Air Conditioning - Change 4, November 1, 2017

UFC 3-401-01: Mechanical Engineering - Change 1, October, 2015

UFC 3-301-01: Structural Engineering - October 1, 2019

UFC 3-240-01: WasteWater Collection - Change 2, January 1, 2019

UFC 3-230-01: Water Storage, Distribution, and Transmission

- Change 1, October 1, 2018

UFC 3-220-01: Geotechnical Engineering - November 1, 2012

UFC 3-210-10: Low Impact Development - Change 1, February 1, 2016

UFC 3-201-02: Landscape Architecture - Change 2, March 19, 2019

UFC 3-201-01: Civil Engineering - June 1, 2013 UFC 3-120-10: Interior Design - May 16, 2018

UFC 3-110-03: Roofing - Change 3, March 6, 2019

UFC 3-101-01: Architecture - Change 5, September 25, 2019

UFC 1-200-02: High Performance and Sustainable Building Requirements

- Change 4, October 1, 2019

UFC 1-200-01: General Building Requirements - October 8, 2019

Core Uniform Facility Criteria (UFC)

Department of Defense (DoD) Design Requirements:

Applicable Design Criteria and Codes:

Madison, Wisconsin

Truax Field ANGB

ANGB-ADAL Building 404 - Wisconsin Air National Guard Project Name and Location:

APPLICABLE CODES AND DESIGN CRITERIA

Group A (Assembly) Occupancies 250 feet Group B (Business) Occupancies 300 feet

NFPA 101

Travel Distance to Exits:

Group A (Assembly) Occupancies w/ fixed seating 75 feet with sprinkler Group B (Business) Occupancies 100 feet with sprinkler

NFPA 101

Common Path of Travel:

Group A (Assembly) Occupancies w/ fixed seating 20 feet with sprinkler Group B (Business) Occupancies 50 feet with sprinkler

NFPA 101

Dead-end Corridor Distance:

300 x .2 = 64 inches width required

Other egress = .2 inches per occupant

NFPA 101 Table 7.3.3.1 Minumum Exterior Door is = 36"

Minumum clear width = 32"

NFPA 101 Section 7.2.1.2.3

Means of Egress:

Not less than 44-inches minimum

Clear width of any corridor or passageway

NFPA 101 Section 12.2.3.8

Corridors:

Floor Classification: Class I or II (Minimum)

NFPA 101

Interior Walls and Ceilings: Class A or B (Minimum)

NFPA 101

Interior Wall and Ceiling Finishes:

X ≥ 30 ft 0 hr

Group B, Type IIB Construction

Exterior Nonbearing Walls and Partitions where "x" is distance from fire separation

IBC Table 602

Fire-Resistance Rating Requirements for Exterior Walls Based on Fire Separation...

Roof Construction 0 hr

Floor Construction 0 hr

Interior 0 hr Nonbearing walls and Partitions

Exterior 0 hr

Nonbearing walls and Partitions

Interior 0 hr Exterior 0 hr Bearing Walls

Primary structural frame 0 hr

Group B & A3, Type IIB Construction

IBC Table 601

Fire-Resistance Rating Requirements for Building Elements (Hours)

Actual Gross Building Area = 22,893 SF

Work Area 'C' = 1,030 SF

Work Area 'B' = 2,355 SF

Work Area 'A' = 4,700 SF

Group A3 / IIB = 38,000 s.f.

IBC Table 506.2:

Building Area:

Actual Stories = 1

Group A3 / IIB = 3 Stories

IBC Table 504.4:

Allowable Number of Stories Above Grade Plane

Actual Building Height = 20 feet

Group A-3 / IIB = 75 Feet High

IBC Table 504.3:

Allowable Building Height

Sprinklered: Yes

Type IIB, Non-Combustible, Unprotected

IBC Table 601

Construction Type:

NFPA 101 (Chapter 42): Assembly Group A3 (Training) Non-separated Mixed Use

NFPA 101 (Chapter 40): Storage Group S-1 (Industrial)

NFPA 101 (Chapter 38): Business Group B (Offices / Training)

Building Occupancy Classifications:

Madison, Wisconsin

Truax Field ANGB

ANGB-ADAL Squadron Operations, B404 - Wisconsin Air National Guard

Project Name and Location:

FIRE PROTECTION AND LIFE SAFETY CODE ANALYSIS

140 SOF 582 BUSINESS 150 4 GROUP B: BUSINESS BUSINESS

139 VEST 21 BUSINESS 150 1 GROUP B: BUSINESS BUSINESS

138 ARMS NCOIC 112 BUSINESS 150 1 GROUP B: BUSINESS BUSINESS

137 ARMS 312 BUSINESS 150 2 GROUP B: BUSINESS BUSINESS

135 STORAGE 24 STORAGE 500 1 ACCESSORY STORAGE INCIDENTAL STORAGE

134 TRAINING OFFICER 168 BUSINESS 150 2 GROUP B: BUSINESS BUSINESS

133 SCHEDULING 194 BUSINESS 150 2 GROUP B: BUSINESS BUSINESS

132 FLIGHT COMMANDERS 216 BUSINESS 150 2 GROUP B: BUSINESS BUSINESS

131 HALLWAY 538 BUSINESS 150 4 GROUP B: BUSINESS BUSINESS

130 OHWS 570 BUSINESS 150 4 GROUP B: BUSINESS BUSINESS

129 OFFICE 205 BUSINESS 150 2 GROUP B: BUSINESS BUSINESS

127 HALLWAY 132 BUSINESS 150 1 GROUP B: BUSINESS BUSINESS

126 ALIS SERVERS 602

SPECIAL PURPOSE

INDUSTRIAL

NA 6 ACCESSORY STORAGE INCIDENTAL STORAGE

125 ALIS ADMIN OFFICE 691 BUSINESS 150 5 GROUP B: BUSINESS BUSINESS

124B FIRE ALARM 11 STORAGE 500 1 ACCESSORY STORAGE INCIDENTAL STORAGE

124A ELEC 11 STORAGE 500 1 ACCESSORY STORAGE INCIDENTAL STORAGE

123 HALL 90 BUSINESS 150 1 GROUP B: BUSINESS BUSINESS

122 BREAK ROOM 288 ASSEMBLY 15 20 GROUP A: ASSEMBLY ASSEMBLY

121 STORAGE 101 STORAGE 500 1 ACCESSORY STORAGE INCIDENTAL STORAGE

120 LIBRARY 118

LIBRARY (READING

ROOM)

50 3 GROUP B: BUSINESS BUSINESS

119 BRIEFING ROOM 2 217 BUSINESS 150 2 GROUP B: BUSINESS BUSINESS

118 BRIEFING ROOM 4 217 BUSINESS 150 2 GROUP B: BUSINESS BUSINESS

117 HALLWAY 121 BUSINESS 150 1 GROUP B: BUSINESS BUSINESS

116 BRIEFING ROOM 3 187 BUSINESS 150 2 GROUP B: BUSINESS BUSINESS

115 BRIEFING ROOM 1 183 BUSINESS 150 2 GROUP B: BUSINESS BUSINESS

114 INTEL OIC 107 BUSINESS 150 1 GROUP B: BUSINESS BUSINESS

113 INTEL NCOIC 107 BUSINESS 150 1 GROUP B: BUSINESS BUSINESS

112A SERVER ROOM 76 STORAGE 500 1 ACCESSORY STORAGE INCIDENTAL STORAGE

112 ISSO/ SSM OFFICE 258 BUSINESS 150 2 GROUP B: BUSINESS BUSINESS

111A BRIEFING ROOM 5 185 BUSINESS 150 2 GROUP B: BUSINESS BUSINESS

111 INTEL 812 BUSINESS 150 6 GROUP B: BUSINESS BUSINESS

110 CLASSROOM 724 CLASSROOM 20 37 GROUP B: BUSINESS BUSINESS

109 MISSION PLANNING 1,243 BUSINESS 150 9 GROUP B: BUSINESS BUSINESS

108 WEAPONS 112 STORAGE 500 1 ACCESSORY STORAGE INCIDENTAL STORAGE

COMM/COMPUTER

STORAGE

169 STORAGE 500 1 ACCESSORY STORAGE INCIDENTAL STORAGE

106 ISSO/ISSM OFFICE 256 BUSINESS 150 2 GROUP B: BUSINESS BUSINESS

105 PM/GSSO OPEN OFFICE 567 BUSINESS 150 4 GROUP B: BUSINESS BUSINESS

104 MX DEBRIEF 161 BUSINESS 150 2 GROUP B: BUSINESS BUSINESS

103 SECURED VEST 83 BUSINESS 150 1 GROUP B: BUSINESS BUSINESS

101 LOBBY 408 BUSINESS 150 3 GROUP B: BUSINESS BUSINESS

100 VEST 151 BUSINESS 150 2 GROUP B: BUSINESS BUSINESS

ROOM

NO.

ROOM

NAME

AREA

(ft2)

NFPA 101 USE

PER TABLE TABLE

7.3.1.2

OCCUPANT LOAD

FACTOR (SQM

PER PERSON)

# OF

OCCUPANTS

IBC OCCUPANCY

CLASSIFICATION

NFPA 101 OCCUPANCY

CLASSIFICATION

B404 CALCULATED OCCUPANT LOAD

TOTAL: 363

175 CLASS ROOM 287 CLASSROOM 20 15 GROUP B: BUSINESS BUSINESS

174 PEST 627 STORAGE 500 2 ACCESSORY STORAGE INCIDENTAL STORAGE

173 AFE WORK ROOM 309 STORAGE 500 1 ACCESSORY STORAGE INCIDENTAL STORAGE

172 MECH 472 STORAGE 500 1 ACCESSORY STORAGE INCIDENTAL STORAGE

171 COMM 78 STORAGE 500 1 ACCESSORY STORAGE INCIDENTAL STORAGE

170 ELEC 69 STORAGE 500 1 ACCESSORY STORAGE INCIDENTAL STORAGE

169 VEST 34 BUSINESS 150 1 GROUP B: BUSINESS BUSINESS

168 KITCHEN/VENDING 155 BUSINESS 150 2 GROUP B: BUSINESS BUSINESS

167 BREAK ROOM 786 ASSEMBLY 15 53 GROUP A: ASSEMBLY ASSEMBLY

166C STORAGE 146 STORAGE 500 1 ACCESSORY STORAGE INCIDENTAL STORAGE

166A STORAGE 99 STORAGE 500 1 ACCESSORY STORAGE INCIDENTAL STORAGE

166 MAIN BRIEFING ROOM 956 ASSEMBLY FIXED 72 GROUP A: ASSEMBLY ASSEMBLY

165 HALLWAY 412 BUSINESS 150 3 GROUP B: BUSINESS BUSINESS

164 STORAGE 60 STORAGE 500 1 ACCESSORY STORAGE INCIDENTAL STORAGE

163 JANITOR 34 BUSINESS 150 1 GROUP B: BUSINESS BUSINESS

WOMEN'S TOILET/

LOCKER ROOM

301 BUSINESS 150 3 GROUP B: BUSINESS BUSINESS

161 WOMEN'S ENTRY 35 BUSINESS 150 1 GROUP B: BUSINESS BUSINESS

160 AFE INSPECTION ROOM 517 BUSINESS 150 4 GROUP B: BUSINESS BUSINESS

159 SUPERINTENDENT FEO 131 BUSINESS 150 1 GROUP B: BUSINESS BUSINESS

158 NVG 63 BUSINESS 150 1 GROUP B: BUSINESS BUSINESS

157 AFE NCOIC 120 BUSINESS 150 1 GROUP B: BUSINESS BUSINESS

AIRCREW FLIGHT

EQUIPMENT

748 BUSINESS 150 5 GROUP B: BUSINESS BUSINESS

MEN'S TOILET/ LOCKER

ROOM

699 BUSINESS 150 5 GROUP B: BUSINESS INCIDENTAL STORAGE

154 CONFERENCE ROOM 211

UFC 3-600-01 -

FACTOR

15 15 GROUP B: BUSINESS BUSINESS

153 STAN EVAL 176 BUSINESS 150 2 GROUP B: BUSINESS BUSINESS

152 OPERATIONS CHIEF 132 BUSINESS 150 1 GROUP B: BUSINESS BUSINESS

151 CCA 171 BUSINESS 150 2 GROUP B: BUSINESS BUSINESS

150 OSS COMMANDER 153 BUSINESS 150 2 GROUP B: BUSINESS BUSINESS

149 HALLWAY 88 BUSINESS 150 1 GROUP B: BUSINESS BUSINESS

148 VEST 33 BUSINESS 150 1 GROUP B: BUSINESS BUSINESS

OPERATIONS GROUP

COMMANDER

193 BUSINESS 150 2 GROUP B: BUSINESS BUSINESS

FIGHTER SQUADRON

COMMANDER

175 BUSINESS 150 2 GROUP B: BUSINESS BUSINESS

DIRECTOR OF

OPERATIONS

148 BUSINESS 150 1 GROUP B: BUSINESS BUSINESS

144 AIRFIELD MANAGEMENT 217 BUSINESS 150 2 GROUP B: BUSINESS BUSINESS

143 AFMT NCOIC 121 BUSINESS 150 1 GROUP B: BUSINESS BUSINESS

142 HALLWAY 147 BUSINESS 150 1 GROUP B: BUSINESS BUSINESS

141 VEST 41 BUSINESS 150 1 GROUP B: BUSINESS BUSINESS

140 SOF 582 BUSINESS 150 4 GROUP B: BUSINESS BUSINESS

ROOM

NO.

ROOM

NAME

AREA

(ft2)

NFPA 101 USE

PER TABLE TABLE

7.3.1.2

OCCUPANT LOAD

FACTOR (SQM

PER PERSON)

# OF

OCCUPANTS

IBC OCCUPANCY

CLASSIFICATION

NFPA 101 OCCUPANCY

CLASSIFICATION

B404 CALCULATED OCCUPANT LOAD - CONTINUED

SECURITY ZONE DIAGRAM LEGEND:

SECURITY ZONE 1

SECURITY ZONE 2

SECURITY ZONE 3

SECURITY WALLS

• ICD-705 REQUIREMENTS

• STC-55 RATED

• SECURE ALL

PENETRATIONS

• SURFACE MOUNT

OUTLETS AND CONDUIT

• DOOR AND FRAME

ASSEMBLY SHALL MEET

STC-50 SECURE

REQUIREMENTS

• PERIMETER OFFSET

RETURN AIRS

SECURE ROOM

SECURE AREA GENERAL NOTES:

1. THE VAULT AREA (MISSION PLANNING, INTELLIGENCE, ALIS SERVER AND

ASSOCIATED SUPPRORT AREAS) IS CONSIDERED A SECURE AREA. ALL NEW

CONSTRUCTION AND RENOVATION TO THE AREA INCLUDING WALL

CONSTRUCTION, FIRE PROTECTION/DETECTION, MECHANICAL/HVAC,

ELECTRICAL, AND TECHNOLOGY SYSTEMS MUST COMPLY WITH THE

REQUIREMENTS PROVIDED IN UNIFIED FACILITY CRITERIA 4-010-05 SENSITIVE

COMPARTMENTED INFORMATION FACILITY PLANNING, DESIGN, AND

CONSTRUCTION WITH CHANGE 1, 1 OCTOBER 2013, AND REFERENCED IC

TECH SPEC FOR ICD/ICS 705 TECHNICAL SPECIFICATIONS FOR

CONSTRUCTION AND MANAGEMENT OF SENSITIVE COMPARTMENTED

INFORMATION FACILITIES, VERSION 1.5, DATED 13 MARCH 2020.

2. CONSTRUCTION, GENERAL: UFC 4-010-05 REQUIREMENTS HAVE BEEN

INCORPORATED INTO THE DESIGN DRAWINGS AND SPECIFICATIONS.

CHANGES TO THE SCOPE OF WORK PROVIDED IN THE CONTRACT

DOCUMENTS MAY INVALIDATE THE APPROVALS RECEIVED FOR THIS

CONSTRUCTION, AND COULD RESULT IN THE REMOVAL AND

RECONSTRUCTION OF FINISHED WORK. ANY PROPOSED DEVIATIONS FROM

THE CONTRACT DOCUMENTS MUST BE FULLY REVIEWED AND APPROVED BY

THE COR PRIOR TO IMPLEMENTATION.

3. ALL CONSTRUCTION MUST BE DONE IN SUCH A MANNER AS TO PROVIDE

VISUAL EVIDENCE OF UNAUTHORIZED PENETRATION - WITH A LEVEL 5 GYP

BD OR EQUIVALENT FINISH FROM FINISH FLOOR TO ROOF DECK.

CONSTRUCTION MUST BE COMPLETED IN A MANNER TO PROVIDE THE

REQUIRED STC RATINGS FOR SOUND CONTROL AT THE WALLS IDENTIFIED.

THROUGH-WALL PENETRATIONS OF PIPE, CONDUIT, AND DUCTWORK

REQUIRE SPECIAL CONSTRUCTION AND INSPECTION PROVISIONS WHICH

HAVE BEEN INCORPORATED INTO THE CONTRACT DOCUMENTS.

4. THE CONTRACTOR SHALL SUBMIT A LIST OF ALL MATERIALS USED IN THE

CONSTRUCTION OF THE VAULT AREA, INCLUDING DIMENSIONAL EXTENTS OF

THE USE AND LOCATION(S) WHERE USED IN THE VAULT. THIS LIST SHALL BE

KEPT UP TO DATE DURING THE COURSE OF CONSTRUCTION AND SUBMITTED

TO THE COR AS PART OF THE CLOSE-OUT REQUIREMENTS AT THE END OF

CONSTRUCTION.

5. PHOTOGRAPHY REQUIREMENTS: THE CONTRACTOR IS NOT ALLOWED TO

HAVE PHOTOGRAPHIC OR RECORDING DEVICES IN THE VAULT AREA. 115 FW

CCZ PERSONNEL WILL BE TAKING PICTURES OF ON-GOING CONSTRUCTION

IN ORDER TO DOCUMENT THAT ALL SECURITY MEASURES ARE BEING MET.

THE COR SHALL BE NOTIFIED AT LEAST ONE WORKING DAY PRIOR TO KEY

CONSTRUCTION MILESTONES. KEY CONSTRUCTION MILESTONES INCLUDE

BUT ARE NOT LIMITED TO: WALL CONSTRUCTION, INCLUDING EACH OF

MULTIPLE LAYERS OF GYPSUM BOARD, FINISHING OF PENETRATIONS,

NON-CONDUCTIVE BREAKS OF PENETRATIONS, AND SOUND BATT

INSULATION INSTALLATIONS.

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

/4

/2

:5

:2

P M

C

R e v it L o c a l\

-1

.0 -A

-C e n tr a l-s z k .r v t

T R

U A

X F

IE

L D

A N

G B

M A

D

IS

O N

W

I

F -3

A D

A L B

U

IL

D

IN

G

G-102

SECURITY ZONE

DIAGRAM PLAN

XGFG182010ANG NO.:

3141300-190289.02

KLU

JJB

JULY 31, 2020

SZK

PLAN

NORTH

TRUE

NORTH

1/8" = 1'-0"1

SECURITY ZONE DIAGRAM

07/31/20 TYPE B3 FINAL

W

V

C

W V

D

S

D

S

D

S

D

S

D

S

D

S

W

V

W

V

W

V

B B

C

O

S

B

B

B

C

G

M

B

W

V

B400

FFE=858.4

T

D

W

V

C

O

B

W A

W A

W A

W A

W A

W A

G

M

T R

A N

S

B

C B

S

B

BBBB

BB

B

B B

BB

B

.5

.5

0 8

859.5

EXISTING CONCRETE SIDEWALK

EXISTING CONCRETE SIDEWALK

E X

I S

T I N

G

C

O N

C R

E T

E

S

I D

E W

A L

K

EXISTING

TURF

EXISTING ASPHALT

E X

I S

T I N

G

C

O N

C R

E T

E

S

I D

E W

A L

K

EXISTING ASPHALT

EXISTING

ASPHALT

E X

I S

T I N

G

C

O N

C R

E T

E

EXISTING CONCRETE SIDEWALK

EXISTING CONCRETE SIDEWALK

EXISTING TURF

EXISTING TRENCH DRAIN

EXISTING CURB INLET

RIM EL = 857.41

EXISTING AC UNITS

EXISTING

COMM. TOWER

EXISTING

LIGHT POLE

(1)FIREBIRD CRABAPPLE (STD)

Malus sargentii 'Select A' (STD)

(1)ICEE BLUE JUNIPER

Juniperus horizontalis 'Monber'

(5)EUONYMUS WINTERCREEPER

Euonymus fortunei 'Coloratus'

EXISTING SIGN

EXISTING

SIGN

LANDSCAPE STONE

LANDSCAPE STONE

SOIL BORING:

JUNE 2016

B404 OPERATIONS

FFE=859.84

PROTECT EXISTING

TOWER THROUGHOUT

CONSTRUCTION

EXISTING

TURF

EXISTING

TURF

EXISTING

TURF

EXISTING ASPHALT

EXISTING

TURF

EXISTING

TURF

EXISTING

TURF

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

SHEET NO.

© Copyright 2020

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

Mead & Hunt, Inc.

ANG NO.:

07/31/2020TYPE B3 FINAL

JULY 31, 2020

T R

U A

X

F

I E

G

B

F

A

L T

I L

D I N

G

M A

D I S

O N

W

I

ISSUED

3141300-190289.02

XGFG182010

00 10 20

C-021

EXISTING SITE PLAN

EXISTING LEGEND:

BENCHMARK

BOLLARD

CONTROL POINT

CLEANOUT, SANITARY OR STORM

DOWNSPOUT

ELECTRICAL / COMMUNICATIONS PEDESTAL

ELECTRICAL TRANSFORMER BOX

ELECTRICAL SERVICE PANEL

ELECTRICAL HANDHOLE/PULLBOX

FIRE HYDRANT

GAS METER

GUY WIRE

INLET, CURB

INLET, ROUND

INLET, SQUARE

LIGHT POLE (SINGLE)

MANHOLE, ELECTRIC

MANHOLE, SANITARY SEWER

MANHOLE, STORM SEWER

MANHOLE, TELECOMMUNICATIONS

POWER POLE

SIGN (SINGLE POST)

SOIL BORING

WATER VALVE

GAS

ELECTRIC, UNDERGROUND

EXISTING CONTOUR LINES

FENCE

FIBER OPTIC CABLE

SANITARY SEWER

STORM SEWER / CULVERT

SWALE

TELEPHONE

TV CABLE

WATER

ABANDONED WATER

OVERHEAD ELECTRIC

SITE LANDSCAPING ROCK

B

CO

DS

TRANS

ESP

E

GM

CB

CB

E

S

D

C

W V xxx.x xxx.x

W\\A//

KSF

CAJ

KSD

TRUE

NORTH

SURVEY DATA:

SURVEY DATE(S)

JUNE 10 & 14, 2016

COORDINATE SYSTEM DANE COUNTY

VERTICAL DATUM USGS NAVD 88

CONTROL SOURCE WISCORS

SURVEY UNITS US SURVEY FOOT

SITE SURVEY NOTES:

1. CONTOUR INTERVALS SHOWN ARE 0.5'.

2. CONTRACTOR SHALL NOT BEGIN EXCAVATION UNTIL ALL EXISTING

UNDERGROUND UTILITIES WITHIN THE PROJECT SITE HAVE BEEN

LOCATED. IT IS THE CONTRACTORS RESPONSIBILITY TO FIELD

VERIFY AND LOCATE UTILITIES. LOCATIONS IN THE PLANS ARE

SHOWN FOR REFERENCE ONLY. UTILITY LOCATIONS SHOWN IN

PLANS HAVE BEEN DETERMINED BY UTILITIES LOCATED PRIOR TO

FIELD SURVEY, AS-BUILT, AND OTHER AVAILABLE RESOURCES.

3. SANITARY SEWER AND STORM SEWER LOCATIONS HAVE BEEN

DETERMINED BY OBSERVABLE SURFACE STRUCTURES AND

RESPECTIVE FEATURES. INTERMEDIATE PIPE LOCATIONS ARE

APPROXIMATE AS ACCURATE LOCATIONS WERE NOT AVAILABLE AT

TIME OF SURVEY.

4. CONTROL POINTS AND BENCHMARKS SHOWN HEREON ARE FOR

REFERENCE PURPOSES ONLY. PRIOR TO STAKING, THE CONTROL

MUST BE INDEPENDENTLY VERIFIED AS UNDISTURBED. NO

WARRANTY IS MADE WITH RESPECT TO THE ACCURACY OF CONTROL

SHOWN HEREON AS THEY ARE SUBJECT TO POTENTIAL

DISTURBANCE.

EUONYMUS WINTER CREEPER

ICEE BLUE JUNIPER

FIREBIRD CRABAPPLE (STD)

W V

D

S

D

S

D

S

D

S

D

S

D

S

W

V

W

V

W

V

B B

C

O

S

B

B

B

C

G

M

B

W

V

B400

FFE=858.4

T

D

W

V

C

O

B

W A

W A

W A

W A

W A

W A

G

M

T R

A N

S

B

C B

S

B

BBBBBBB

B

B

BB

B

REMOVE LANDSCAPING

ADJACENT TO ADDITION

REMOVE BOLLARDS

RELOCATE TRANSFORMER

EXISTING CONCRETE SIDEWALK

EXISTING CONCRETE SIDEWALK

E X

I S

T I N

G

C

O N

C R

E T

E

S

I D

E W

A L

K

EXISTING ASPHALT

EXISTING ASPHALT

EXISTING

ASPHALT

E X

I S

T I N

G

C

O N

C R

E T

E

S

I D

E W

A L

K

REMOVE LANDSCAPE

STONE

REMOVE BOLLARDS

REMOVE CONCRETE PAD

XXXXXXXXXXXXXXXXXXXXXXXXXX

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X

X X

X X

X X

X X

X X

X X

REMOVE CONCRETE

REMOVE AND

CURB

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

6.10'

8.00'

81.46'

22.05'

33.01'

7.85'

10.54'

21.19'

9.64'

5.24'

11.01'

10.00'

28.00'

3.81'

12.31'

REMOVE ASPHALT

SAW CUT PAVEMENT TO NEAREST JOINT

PROJECT LIMIT

FOR BUILDING 404

26.67'

REMOVAL OF ROADWAY

BOLLARDS (ADDITIVE BID ITEM)

REMOVE TOPSOIL

B404 OPERATIONS

FFE=859.84

PROTECT

EXISTING TOWER

THROUGHOUT

CONSTRUCTION

ISSUED

3141300-190289.02

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

SHEET NO.

© Copyright 2020

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

Mead & Hunt, Inc.

ANG NO.:

07/31/2020 TYPE B3 FINAL

JULY 31, 2020

T R

U A

X

F

I E

G

B

F

A

L T

I L

D I N

G

M A

D I S

O N

W

I

XGFG182010

SITE DEMOLITION PLAN NOTES:

1. REMOVE CONCRETE TO THE NEAREST EXISTING JOINT AS REQUIRED TO

PERFORM WORK.

2. SAWCUT PAVEMENTS PRIOR TO REMOVAL.

3. RESAW ASPHALT PAVEMENTS, AS REQUIRED, PRIOR TO PATCHING.

00 10 20

C-041

SITE DEMOLITION

PLAN

KSF

CAJ

KSD

TRUE

NORTH

EUONYMUS WINTER CREEPER

ICEE BLUE JUNIPER

FIREBIRD CRABAPPLE (STD)

REMOVE GATE

REMOVE WATER

REMOVE SANITARY

REMOVE

SAW CUT PAVEMENT

ASPHALT REMOVAL

CONCRETE REMOVAL

GENERAL REMOVAL

FIRE TRUCK ACCESS

//FNC//

//W//

//SS//

XXXXXXXXXXXXXXXXXXX

FLOW DIRECTION

EXISTING CONTOUR LINES

PROPOSED CONTOUR LINES

GRADING LIMITS

FINISHED / PROPOSED SPOT ELEVATION

FINISHED / PROPOSED SLOPE

xxx.x xxx.x xxx(.xx) xxx(.xx)

2%

3:1

CONCRETE

ASPHALT

INLET PROTECTION

SILT FENCE

STORM SEWER / CULVERT

STORM FLARED END SECTION

STORM SEWER MANHOLE

D

PROPOSED LEGEND:

BENCHMARK

BOLLARD

CONTROL POINT

CLEANOUT, SANITARY OR STORM

DOWNSPOUT

ELECTRICAL / COMMUNICATIONS PEDESTAL

ELECTRICAL TRANSFORMER BOX

ELECTRICAL SERVICE PANEL

ELECTRICAL HANDHOLE/PULLBOX

FIRE HYDRANT

GAS METER

GUY WIRE

INLET, CURB

INLET, ROUND

INLET, SQUARE

LIGHT POLE (SINGLE)

MANHOLE, ELECTRIC

MANHOLE, SANITARY SEWER

MANHOLE, STORM SEWER

MANHOLE, TELECOMMUNICATIONS

POWER POLE

SIGN (SINGLE POST)

SOIL BORING

WATER VALVE

GAS

ELECTRIC, UNDERGROUND

EXISTING CONTOUR LINES

FENCE

FIBER OPTIC CABLE

SANITARY SEWER

STORM SEWER / CULVERT

SWALE

TELEPHONE

TV CABLE

WATER

ABANDONED WATER

OVERHEAD ELECTRIC

SITE LANDSCAPING ROCK

B

CO

DS

TRANS

ESP

E

GM

CB

CB

E

S

D

C

W V xxx.x xxx.x

W\\A//

C

W V

D

S

D

S

D

S

D

S

D

S

D

S

W

V

W

V

W

V

B B

C

O

S

B

B

B

C

G

M

W

V

B400

FFE=858.4

T

D

W

V

C

O

B

G

M

C B

S

F.E.

F.E.

REF.

D W

R E

F

DW

ID-01ID-01

FEC

FEC

FEC

FEC

FECAED

SC3

ALIS

SERVERS

ALIS

ADMIN

OFFICE

PEST

CLASS ROOM

CCA

OSS

COMMANDER

OPERATIONS

GROUP

COMMANDER

FIGHTER

SQUADRON

COMMANDER

VEST

HALLWAY

DIRECTOR OF

OPERATIONS

AIRFIELD

MANAGEMENT

AFMT

NCOIC

OPERATIONS

CHIEF

STAN

EVAL

CONFERENCE

ROOM

AFE

NCOIC

MEN'S

TOILET/

LOCKER

ROOM

AIRCREW

FLIGHT

EQUIPMENT

SOF

OFFICE

SCHEDULING

STORAGE

FLIGHT

COMMANDERS

ARMS

ARMS NCOIC

SECURED

VEST

MX DEBRIEF

COMM/

COMPUTER

STORAGE

WEAPONS

ISSO/ISSM

OFFICE

CLASSROOM

GSSO/ ISSO/

SSM OFFICE

INTEL

INTEL

NCOIC

INTEL

OIC

BRIEFING

ROOM 3

BRIEFING

ROOM 1

BRIEFING

ROOM 2

BRIEFING

ROOM 4

LIBRARY

STORAGE

BREAK

ROOM

MISSION

PLANNING

OPEN

OFFICE

VEST

LOBBY

MAIN

BRIEFING

ROOM

KITCHEN/

VENDING

BREAK ROOM

VEST

HALLWAY

STORAGE

AFE

INSPECTION

ROOM

COMM

ELEC

AFE

STORAGE

MECH

124A

ELEC

FIRE

ALARM

124B

JANITOR

WOMEN'S

TOILET/

LOCKER

ROOM

AFE

SUPERINTENDENT,

FEO

NVG

COPY ROOM

TRAINING

OFFICER

HALLWAY

VEST

HALLWAY

HALLWAY

WOMENS

ENTRY

166A

STORAGE

166B

STORAGE

166C

STORAGE

111A

BRIEFING

ROOM 5

MX6

SC3

SC6

SC6

4.100 4.100

111A

4.100

SA3

SA6

SA3

SA3

SA3

SA3

SA3

FC3 FC3

SA3

FA78

SC3

SA3

SC3

SC3

SA3

OHWS

4.100

SA6

FC2

SC3

SA3

SC3

SA3SA3SA3

SA3

SA3

SA3

HALLWAY

MA8

MA8

MA8

MA8

MA8

SA3

MISSION

PLANNING

A-301

MX6

SC6

4.100

FC3

FC3

FC3

FC3

FC3

ACRYLIC

PANEL

PARTITION

174C

B

SC3

SA3

124A

124B

TRANS

B

B

B

B

D

D

NEW ADDITION

NEW ADDITION

EXISTING ASPHALT

16.0'

LANDSCAPE

RESTORATION

EXISTING TURF

LANDSCAPE RESTORATION

S T

O R

M

D

R A

I N

A G

E

D R

Y

P

O N

D

STORM DRAINAGE

DRY POND

EXISTING CONCRETE SIDEWALK

EXISTING

CONCRETE

SIDEWALK

LANDSCAPE STONE

(1)FIREBIRD CRABAPPLE (STD)

Malus sargentii 'Select A' (STD)

(1)ICEE BLUE JUNIPER

Juniperus horizontalis 'Monber'

(5)EUONYMUS WINTERCREEPER

Euonymus fortunei 'Coloratus'

EXISTING PATIO

EXISTING SIDEWALK

EXISTING TURF

LANDSCAPE

RESTORATION

EXISTING TURF

EXISTING TURF

EXISTING TURF

EXISTING TURF

6.0'

10'X10' CONCRETE

BASE SLAB @

EXISTING TOWER TO

BE CONSTRUCTED

UNDER DIFFERENT

PROJECT, AFTER

THIS WORK

SEED AND SOD

8.00'

6.11'

CONCRETE PAD

ASPHALT

RELOCATED

TRANSFORMER

EXISTING CONCRETE STOOP

9'x7.5' ISU UNITS

PROJECT LIMIIT

FOR BUILDING 404

REPLACE CONCRETE

SIDEWALK SECTION

REPAIR 20LF OF

CURB AFTER STORM

SEWER CONNECTION

BOLLARDS

CURB, TYPICAL

LANDSCAPE RESTORATION

LANDSCAPE

RESTORATION

6.15'

LIMESTONE

3141300-190289.02

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

SHEET NO.

© Copyright 2020

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

Mead & Hunt, Inc.

ANG NO.:

07/31/2020 TYPE B3 FINAL

JULY 31, 2020

T R

U A

X

F

I E

G

B

F

A

L T

I L

D I N

G

M A

D I S

O N

W

I

XGFG182010

00 10 20

C-101

SITE IMPROVEMENTS

PLAN

KSF

CAJ

KSD

TRUE

NORTH

EUONYMUS WINTER CREEPER

ICEE BLUE JUNIPER

FIREBIRD CRABAPPLE (STD)

REMOVE GATE

REMOVE WATER

REMOVE SANITARY

REMOVE

SAW CUT PAVEMENT

ASPHALT REMOVAL

CONCRETE REMOVAL

GENERAL REMOVAL

FIRE TRUCK ACCESS

//FNC//

//W//

//SS//

XXXXXXXXXXXXXXXXXXX

FLOW DIRECTION

EXISTING CONTOUR LINES

PROPOSED CONTOUR LINES

GRADING LIMITS

FINISHED / PROPOSED SPOT ELEVATION

FINISHED / PROPOSED SLOPE

xxx.x xxx.x xxx(.xx) xxx(.xx)

2%

3:1

CONCRETE

ASPHALT

INLET PROTECTION

SILT FENCE

STORM SEWER / CULVERT

STORM FLARED END SECTION

STORM SEWER MANHOLE

D

PROPOSED LEGEND:

BENCHMARK

BOLLARD

CONTROL POINT

CLEANOUT, SANITARY OR STORM

DOWNSPOUT

ELECTRICAL / COMMUNICATIONS PEDESTAL

ELECTRICAL TRANSFORMER BOX

ELECTRICAL SERVICE PANEL

ELECTRICAL HANDHOLE/PULLBOX

FIRE HYDRANT

GAS METER

GUY WIRE

INLET, CURB

INLET, ROUND

INLET, SQUARE

LIGHT POLE (SINGLE)

MANHOLE, ELECTRIC

MANHOLE, SANITARY SEWER

MANHOLE, STORM SEWER

MANHOLE, TELECOMMUNICATIONS

POWER POLE

SIGN (SINGLE POST)

SOIL BORING

WATER VALVE

GAS

ELECTRIC, UNDERGROUND

EXISTING CONTOUR LINES

FENCE

FIBER OPTIC CABLE

SANITARY SEWER

STORM SEWER / CULVERT

SWALE

TELEPHONE

TV CABLE

WATER

ABANDONED WATER

OVERHEAD ELECTRIC

SITE LANDSCAPING ROCK

B

CO

DS

TRANS

ESP

E

GM

CB

CB

E

S

D

C

W V xxx.x xxx.x

SS

W

W\\A//

AutoCAD SHX Text

B404 OPERATIONS FFE=859.84

C

O

F.E.

PEST

OSS

COMMANDER

VEST

COMM

ELEC

AFE

STORAGE

MA8

A-301

B

30.0'

15.4'

XE

E

E E

X

X

X

XX

X X

X

X

X

X

8.5'

3.7'

5.9'

5.2' 4.9'

5.9'

5.9'

5.2'

3141300-190289.02

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

SHEET NO.

© Copyright 2020

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

Mead & Hunt, Inc.

ANG NO.:

07/31/2020 TYPE B3 FINAL

JULY 31, 2020

T R

U A

X

F

I E

G

B

F

A

L T

I L

D I N

G

M A

D I S

O N

W

I

XGFG182010

00 2 4

C-102

CONCRETE JOINTING

PLAN

XXX

CAJ

KSD

TRUE

NORTH

X = DOWELED CONTRACTION JOINTS

= EXPANSION JOINTSE

JOINTING PLAN NOTES:

SEE SHEET C503 FOR JOINTING DETAILS

EUONYMUS WINTER CREEPER

ICEE BLUE JUNIPER

FIREBIRD CRABAPPLE (STD)

REMOVE GATE

REMOVE WATER

REMOVE SANITARY

REMOVE

SAW CUT PAVEMENT

ASPHALT REMOVAL

CONCRETE REMOVAL

GENERAL REMOVAL

FIRE TRUCK ACCESS

//FNC//

//W//

//SS//

XXXXXXXXXXXXXXXXXXX

FLOW DIRECTION

EXISTING CONTOUR LINES

PROPOSED CONTOUR LINES

GRADING LIMITS

FINISHED / PROPOSED SPOT ELEVATION

FINISHED / PROPOSED SLOPE

xxx.x xxx.x xxx(.xx) xxx(.xx)

2%

3:1

CONCRETE

ASPHALT

INLET PROTECTION

SILT FENCE

STORM SEWER / CULVERT

STORM FLARED END SECTION

STORM SEWER MANHOLE

D

PROPOSED LEGEND:

BENCHMARK

BOLLARD

CONTROL POINT

CLEANOUT, SANITARY OR STORM

DOWNSPOUT

ELECTRICAL / COMMUNICATIONS PEDESTAL

ELECTRICAL TRANSFORMER BOX

ELECTRICAL SERVICE PANEL

ELECTRICAL HANDHOLE/PULLBOX

FIRE HYDRANT

GAS METER

GUY WIRE

INLET, CURB

INLET, ROUND

INLET, SQUARE

LIGHT POLE (SINGLE)

MANHOLE, ELECTRIC

MANHOLE, SANITARY SEWER

MANHOLE, STORM SEWER

MANHOLE, TELECOMMUNICATIONS

POWER POLE

SIGN (SINGLE POST)

SOIL BORING

WATER VALVE

GAS

ELECTRIC, UNDERGROUND

EXISTING CONTOUR LINES

FENCE

FIBER OPTIC CABLE

SANITARY SEWER

STORM SEWER / CULVERT

SWALE

TELEPHONE

TV CABLE

WATER

ABANDONED WATER

OVERHEAD ELECTRIC

SITE LANDSCAPING ROCK

B

CO

DS

TRANS

ESP

E

GM

CB

CB

E

S

D

C

W V xxx.x xxx.x

SS

C

W V

D

S

D

S

D

S

D

S

D

S

D

S

W

V

W

V

W

V

B B

C

O

S

B

B

B

C

G

M

W

V

B400

FFE=858.4

T

D

W

V

C

O

B

G

M

C B

S

F.E.

F.E.

REF.

D W

R E

F

DW

ID-01ID-01

FEC

FEC

FEC

FEC

FECAED

SC3

ALIS

SERVERS

ALIS

ADMIN

OFFICE

PEST

CLASS ROOM

CCA

OSS

COMMANDER

OPERATIONS

GROUP

COMMANDER

FIGHTER

SQUADRON

COMMANDER

VEST

HALLWAY

DIRECTOR OF

OPERATIONS

AIRFIELD

MANAGEMENT

AFMT

NCOIC

OPERATIONS

CHIEF

STAN

EVAL

CONFERENCE

ROOM

AFE

NCOIC

MEN'S

TOILET/

LOCKER

ROOM

AIRCREW

FLIGHT

EQUIPMENT

SOF

OFFICE

SCHEDULING

STORAGE

FLIGHT

COMMANDERS

ARMS

ARMS NCOIC

SECURED

VEST

MX DEBRIEF

COMM/

COMPUTER

STORAGE

WEAPONS

ISSO/ISSM

OFFICE

CLASSROOM

GSSO/ ISSO/

SSM OFFICE

INTEL

INTEL

NCOIC

INTEL

OIC

BRIEFING

ROOM 3

BRIEFING

ROOM 1

BRIEFING

ROOM 2

BRIEFING

ROOM 4

LIBRARY

STORAGE

BREAK

ROOM

MISSION

PLANNING

OPEN

OFFICE

VEST

LOBBY

MAIN

BRIEFING

ROOM

KITCHEN/

VENDING

BREAK ROOM

VEST

HALLWAY

STORAGE

AFE

INSPECTION

ROOM

COMM

ELEC

AFE

STORAGE

MECH

124A

ELEC

FIRE

ALARM

124B

JANITOR

WOMEN'S

TOILET/

LOCKER

ROOM

AFE

SUPERINTENDENT,

FEO

NVG

COPY ROOM

TRAINING

OFFICER

HALLWAY

VEST

HALLWAY

HALLWAY

WOMENS

ENTRY

166A

STORAGE

166B

STORAGE

166C

STORAGE

111A

BRIEFING

ROOM 5

MX6

SC3

SC6

SC6

4.100 4.100

111A

4.100

SA3

SA6

SA3

SA3

SA3

SA3

SA3

FC3 FC3

SA3

FA78

SC3

SA3

SC3

SC3

SA3

OHWS

4.100

SA6

FC2

SC3

SA3

SC3

SA3SA3SA3

SA3

SA3

SA3

HALLWAY

MA8

MA8

MA8

MA8

MA8

SA3

MISSION

PLANNING

A-301

MX6

SC6

4.100

FC3

FC3

FC3

FC3

FC3

ACRYLIC

PANEL

PARTITION

174C

B

SC3

SA3

124A

124B

TRANS

B

B

B

B

S D

S D

S D

S D

S D

S D

S D

S D

S D

D

D

NEW ADDITION

FFE=859.84

NEW ADDITION

FFE=859.84

EXISTING ASPHALT

EXISTING ASPHALT

LANDSCAPE

RESTORATION

EXISTING TURF

EXISTING TURF

S T

O R

M

D

R A

I N

A G

E

D R

Y

P

O N

D

STORM DRAINAGE

DRY POND

EXISTING CONCRETE SIDEWALK

EXISTING

CONCRETE

SIDEWALK

EXISTING PATIO

EXISTING SIDEWALK

EXISTING TURF

EXISTING TURF

EXISTING TURF

EXISTING TURF

x xxxxxx

6' TALL TEMPORARY CHAIN LINK

CONSTRUCTION FENCE PLACE

12" SEDIMENT LOG INSIDE FENCE.

(SEE DETAILS 1 AND 3 ON SHEET C502)

SILT FENCE

(SEE DETAIL 2

SHEET C502)

PROJECT LIMIT

FOR BUILDING 404

TYPE D INLET PROTECTION, TYP.

(SEE DETAIL 5 SHEET C502)

FLARED HEADWALL

(SEE DETAIL 6

SHEET C501)

FLARED HEADWALL

(SEE DETAIL 6

SHEET C501)

-1.80%

-1.72%

-1.80%

TOPSOIL STORAGE AREA

INLET PROTECTION

(SEE DETAIL 5

SHEET C502)

INLET PROTECTION

(SEE DETAIL 5

SHEET C502)

CAJ

KSD

3141300-190289.02

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

SHEET NO.

© Copyright 2020

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

Mead & Hunt, Inc.

ANG NO.:

07/31/2020 TYPE B3 FINAL

JULY 31, 2020

T R

U A

X

F

I E

G

B

F

A

L T

I L

D I N

G

M A

D I S

O N

W

I

XGFG182010

00 10 20

C-121

SITE GRADING AND

EROSION CONTROL

PLAN

EROSION CONTROL PLAN NOTES:

1. CONSTRUCTION SITE EROSION AND SEDIMENT CONTROL SHALL COMPLY WITH THE REQUIREMENTS OF

THE WISCONSIN DEPARTMENT OF NATURAL RESOURCES.

2. ALL EROSION CONTROL MEASURES SHALL BE ADJUSTED TO MEET FIELD CONDITIONS.

3. EROSION CONTROL MEASURES SHALL BE INSTALLED PRIOR TO ANY GRADING OR DISTURBANCE OF

SURFACE MATERIAL.

4. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS NEEDED.

5. EROSION AND SEDIMENT CONTROL SHALL BE INSPECTED WEEKLY AND WITHIN 24 HOURS OF ANY RAIN

EVENT OF 0.5-INCHES OR MORE IN A 24 HOUR PERIOD. A LOG OF ALL INSPECTIONS SHALL BE MAINTAINED

THROUGHOUT THE DURATION OF THE PROJECT.

6. CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANUP AND REMOVAL OF ALL SEDIMENT LEAVING THE SITE.

EROSION CONTROL MEASURES SHALL BE IN WORKING CONDITION AT THE END OF EACH WORKING DAY.

THE CONTRACTOR SHALL SWEEP THE DRIVES ACCESSING THE APRON AT LEAST ONCE PER DAY AND HAVE

SWEEPING EQUIPMENT AVAILABLE AT ALL TIMES DURING CONSTRUCTION.

7. EROSION CONTROL MEASURES SHALL BE MAINTAINED BY THE CONTRACTOR UNTIL THE SITE IS FULLY

STABILIZED.

8. CONFORM WITH SPECIFICATION 31 23 19 FOR DEWATERING DISCHARGE REQUIREMENTS.

9. CONTRACTOR SHALL IMMEDIATELY SWEEP OR USE VACUUM EQUIPMENT TO REMOVE ANY SEDIMENT THAT

REACHES THE PAVEMENT NEAR THE FLIGHT APRON.

10. GROUNDWATER IS 5 TO 6 FEET BELOW GRADE. IF DEWATERING IS REQUIRED, CONTRACTOR SHALL

SECURE PERMITS AND FOLLOW STATE AND LOCAL REGULATIONS.

KSF

TRUE

NORTH

EUONYMUS WINTER CREEPER

ICEE BLUE JUNIPER

FIREBIRD CRABAPPLE (STD)

REMOVE GATE

REMOVE WATER

REMOVE SANITARY

REMOVE

SAW CUT PAVEMENT

ASPHALT REMOVAL

CONCRETE REMOVAL

GENERAL REMOVAL

FIRE TRUCK ACCESS

//FNC//

//W//

//SS//

XXXXXXXXXXXXXXXXXXX

FLOW DIRECTION

EXISTING CONTOUR LINES

PROPOSED CONTOUR LINES

GRADING LIMITS

FINISHED / PROPOSED SPOT ELEVATION

FINISHED / PROPOSED SLOPE

xxx.x xxx.x xxx(.xx) xxx(.xx)

2%

3:1

CONCRETE

ASPHALT

INLET PROTECTION

SILT FENCE

STORM SEWER / CULVERT

STORM FLARED END SECTION

STORM SEWER MANHOLE

D

PROPOSED LEGEND:

BENCHMARK

BOLLARD

CONTROL POINT

CLEANOUT, SANITARY OR STORM

DOWNSPOUT

ELECTRICAL / COMMUNICATIONS PEDESTAL

ELECTRICAL TRANSFORMER BOX

ELECTRICAL SERVICE PANEL

ELECTRICAL HANDHOLE/PULLBOX

FIRE HYDRANT

GAS METER

GUY WIRE

INLET, CURB

INLET, ROUND

INLET, SQUARE

LIGHT POLE (SINGLE)

MANHOLE, ELECTRIC

MANHOLE, SANITARY SEWER

MANHOLE, STORM SEWER

MANHOLE, TELECOMMUNICATIONS

POWER POLE

SIGN (SINGLE POST)

SOIL BORING

WATER VALVE

GAS

ELECTRIC, UNDERGROUND

EXISTING CONTOUR LINES

FENCE

FIBER OPTIC CABLE

SANITARY SEWER

STORM SEWER / CULVERT

SWALE

TELEPHONE

TV CABLE

WATER

ABANDONED WATER

OVERHEAD ELECTRIC

SITE LANDSCAPING ROCK

B

CO

DS

TRANS

ESP

E

GM

CB

CB

E

S

D

C

W V xxx.x xxx.x

SS

W

W\\A//

C

W V

D

S

D

S

D

S

D

S

D

S

D

S

W

V

W

V

W

V

B B

C

O

S

B

B

B

C

G

M

W

V

B400

FFE=858.4

T

D

W

V

C

O

B

W A

W A

W A

W A

W A

W A

G

M

C B

S

F.E.

F.E.

REF.

D W

R E

F

DW

ID-01ID-01

FEC

FEC

FEC

FEC

FECAED

SC3

ALIS

SERVERS

ALIS

ADMIN

OFFICE

PEST

CLASS ROOM

CCA

OSS

COMMANDER

OPERATIONS

GROUP

COMMANDER

FIGHTER

SQUADRON

COMMANDER

VEST

HALLWAY

DIRECTOR OF

OPERATIONS

AIRFIELD

MANAGEMENT

AFMT

NCOIC

OPERATIONS

CHIEF

STAN

EVAL

CONFERENCE

ROOM

AFE

NCOIC

MEN'S

TOILET/

LOCKER

ROOM

AIRCREW

FLIGHT

EQUIPMENT

SOF

OFFICE

SCHEDULING

STORAGE

FLIGHT

COMMANDERS

ARMS

ARMS NCOIC

SECURED

VEST

MX DEBRIEF

COMM/

COMPUTER

STORAGE

WEAPONS

ISSO/ISSM

OFFICE

CLASSROOM

GSSO/ ISSO/

SSM OFFICE

INTEL

INTEL

NCOIC

INTEL

OIC

BRIEFING

ROOM 3

BRIEFING

ROOM 1

BRIEFING

ROOM 2

BRIEFING

ROOM 4

LIBRARY

STORAGE

BREAK

ROOM

MISSION

PLANNING

OPEN

OFFICE

VEST

LOBBY

MAIN

BRIEFING

ROOM

KITCHEN/

VENDING

BREAK ROOM

VEST

HALLWAY

STORAGE

AFE

INSPECTION

ROOM

COMM

ELEC

AFE

STORAGE

MECH

124A

ELEC

FIRE

ALARM

124B

JANITOR

WOMEN'S

TOILET/

LOCKER

ROOM

AFE

SUPERINTENDENT,

FEO

NVG

COPY ROOM

TRAINING

OFFICER

HALLWAY

VEST

HALLWAY

HALLWAY

WOMENS

ENTRY

166A

STORAGE

166B

STORAGE

166C

STORAGE

111A

BRIEFING

ROOM 5

MX6

SC3

SC6

SC6

4.100 4.100

111A

4.100

SA3

SA6

SA3

SA3

SA3

SA3

SA3

FC3 FC3

SA3

FA78

SC3

SA3

SC3

SC3

SA3

OHWS

4.100

SA6

FC2

SC3

SA3

SC3

SA3SA3SA3

SA3

SA3

SA3

HALLWAY

MA8

MA8

MA8

MA8

MA8

SA3

MISSION

PLANNING

A-301

MX6

SC6

4.100

FC3

FC3

FC3

FC3

FC3

ACRYLIC

PANEL

PARTITION

174C

B

SC3

SA3

124A

124B

TRANS

B

B

B

B

S D

S D

S D

S D

S D

S D

S D

S D

S D

D

D

NEW ADDITION

NEW ADDITION

EXISTING

ASPHALT

EXISTING ASPHALT

LANDSCAPE

RESTORATION

S T

O R

M

D

R A

I N

A G

E

D R

Y

P

O N

D

STORM DRAINAGE

DRY POND

EXISTING CONCRETE SIDEWALK

EXISTING CONCRETE

SIDEWALK

RELOCATED

TRANSFORMER

SEE MECHANICAL

PROJECT LIMIT

FOR BUILDING 404

EXISTING INLET

RIM EL = 857.41

EST SW INV EL = 854.41

NE INV EL = 855.61

7 LF - 8" PVC @ 1.0%

STM MH - 2, R-1550 OR EQUAL

RIM EL = 858.29

SW INV EL = 855.68

NW INV EL = 855.68

67 LF - 8" PVC @ 1.0%

ENDWALL

INV EL = 857.0

STM MH - 1, R-1550 OR EQUAL

RIM EL = 858.29

NW INV EL = 856.36

SW INV EL = 856.93

SE INV EL = 856.35

ENDWALL

INV EL = 857.0

64 LF - 8" PVC @ 1.0%

7 LF - 8" PVC @ 1.0%

INSTALL TWO (2)

4-INCH CONDUITS

3141300-190289.02

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

SHEET NO.

© Copyright 2020

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

Mead & Hunt, Inc.

ANG NO.:

07/31/2020 TYPE B3 FINAL

JULY 31, 2020

T R

U A

X

F

I E

G

B

F

A

L T

I L

D I N

G

M A

D I S

O N

W

I

XGFG182010

00 10 20

C-141

SITE UTILITIES PLAN

SITE UTILITY PLAN NOTES:

1. EXISTING UTILITIES WERE IDENTIFIED FROM THE OWNER'S UITILITY BASE MAP,

PREVIOUS CONSTRUCTION PLANS, AND LIMITED SITE OBSERVATIONS. ALL

UTILITY LOCATIONS SHALL BE CONFIRMED BY THE CONTRACTOR.

2. SITE UTILITY WORK CONSISTS OF NEW CABLING/PIPING REQUIRED FOR

RELOCATION OF TRANSFORMER.

KSF

CAJ

KSD

TRUE

NORTH

EUONYMUS WINTER CREEPER

ICEE BLUE JUNIPER

FIREBIRD CRABAPPLE (STD)

REMOVE GATE

REMOVE WATER

REMOVE SANITARY

REMOVE

SAW CUT PAVEMENT

ASPHALT REMOVAL

CONCRETE REMOVAL

GENERAL REMOVAL

FIRE TRUCK ACCESS

//FNC//

//W//

//SS//

XXXXXXXXXXXXXXXXXXX

FLOW DIRECTION

EXISTING CONTOUR LINES

PROPOSED CONTOUR LINES

GRADING LIMITS

FINISHED / PROPOSED SPOT ELEVATION

FINISHED / PROPOSED SLOPE

xxx.x xxx.x xxx(.xx) xxx(.xx)

2%

3:1

CONCRETE

ASPHALT

INLET PROTECTION

SILT FENCE

STORM SEWER / CULVERT

STORM FLARED END SECTION

STORM SEWER MANHOLE

D

PROPOSED LEGEND:

BENCHMARK

BOLLARD

CONTROL POINT

CLEANOUT, SANITARY OR STORM

DOWNSPOUT

ELECTRICAL / COMMUNICATIONS PEDESTAL

ELECTRICAL TRANSFORMER BOX

ELECTRICAL SERVICE PANEL

ELECTRICAL HANDHOLE/PULLBOX

FIRE HYDRANT

GAS METER

GUY WIRE

INLET, CURB

INLET, ROUND

INLET, SQUARE

LIGHT POLE (SINGLE)

MANHOLE, ELECTRIC

MANHOLE, SANITARY SEWER

MANHOLE, STORM SEWER

MANHOLE, TELECOMMUNICATIONS

POWER POLE

SIGN (SINGLE POST)

SOIL BORING

WATER VALVE

GAS

ELECTRIC, UNDERGROUND

EXISTING CONTOUR LINES

FENCE

FIBER OPTIC CABLE

SANITARY SEWER

STORM SEWER / CULVERT

SWALE

TELEPHONE

TV CABLE

WATER

ABANDONED WATER

OVERHEAD ELECTRIC

SITE LANDSCAPING ROCK

B

CO

DS

TRANS

ESP

E

GM

CB

CB

E

S

D

C

W V xxx.x xxx.x

W\\A//

C

C

B

W V

D

S

D

S

D

S

D

S

D

S

D

S

C

B

C

B

W

V

W

V

W

V

B B

C

O

S

B

B

B

C

G

M

W

V

T

D

W

V

C

O

B

G

M

C B

S

F.E.

F.E.

REF.

D W

R E

F

DW

ID-01ID-01

FEC

FEC

FEC

FEC

FECAED

SC3

ALIS

SERVERS

ALIS

ADMIN

OFFICE

PEST

CLASS ROOM

CCA

OSS

COMMANDER

OPERATIONS

GROUP

COMMANDER

FIGHTER

SQUADRON

COMMANDER

VEST

HALLWAY

DIRECTOR OF

OPERATIONS

AIRFIELD

MANAGEMENT

AFMT

NCOIC

OPERATIONS

CHIEF

STAN

EVAL

CONFERENCE

ROOM

AFE

NCOIC

MEN'S

TOILET/

LOCKER

ROOM

AIRCREW

FLIGHT

EQUIPMENT

SOF

OFFICE

SCHEDULING

STORAGE

FLIGHT

COMMANDERS

ARMS

ARMS NCOIC

SECURED

VEST

MX DEBRIEF

COMM/

COMPUTER

STORAGE

WEAPONS

ISSO/ISSM

OFFICE

CLASSROOM

GSSO/ ISSO/

SSM OFFICE

INTEL

INTEL

NCOIC

INTEL

OIC

BRIEFING

ROOM 3

BRIEFING

ROOM 1

BRIEFING

ROOM 2

BRIEFING

ROOM 4

LIBRARY

STORAGE

BREAK

ROOM

MISSION

PLANNING

OPEN

OFFICE

VEST

LOBBY

MAIN

BRIEFING

ROOM

KITCHEN/

VENDING

BREAK ROOM

VEST

HALLWAY

STORAGE

AFE

INSPECTION

ROOM

COMM

ELEC

AFE

STORAGE

MECH

124A

ELEC

FIRE

ALARM

124B

JANITOR

WOMEN'S

TOILET/

LOCKER

ROOM

AFE

SUPERINTENDENT,

FEO

NVG

COPY ROOM

TRAINING

OFFICER

HALLWAY

VEST

HALLWAY

HALLWAY

WOMENS

ENTRY

166A

STORAGE

166B

STORAGE

166C

STORAGE

111A

BRIEFING

ROOM 5

MX6

SC3

SC6

SC6

4.100 4.100

111A

4.100

SA3

SA6

SA3

SA3

SA3

SA3

S…

This is the start of the file's text. The full file is on GovTribe.