EXHIBIT A PERFORMANCE RELEVANCY QUESTIONNAIRE AND SPECIALIZED COMPANY EXPERIENCE.docx
DOCX document 31 KB Posted
- Attached to
- F-35 ADD/ALTER SQUADRON OPERATIONS 404 Federal contract opportunity
- Solicitation number
- W50S9F-21-R-0001
- Issued by
- Department of the Army National Guard
About this file
This document provides details for a federal contract solicitation to alter and construct additions to an existing facility at Dane County Regional Airport - Truax Field in Madison, Wisconsin. The solicitation seeks a firm fixed-price contract to reconfigure approximately 4,300 square feet of existing space for F-35 operations and construct an additional 1,300 square feet of new space, including 300 square feet for a Sensitive Compartmented Information Facility. Work includes minor demolition, construction of new spaces, and modifications to mechanical, plumbing, electrical and technology systems. The contract duration is 365 days with a pre-proposal site visit on December 28, 2020 and proposals due by January 20, 2021. Evaluation criteria are technical, past performance, and price with award intended without discussions. The solicitation is available through the SAM.gov website and inquiries should be directed to the point of contact specified.
View the file
Other files for this federal contract opportunity
Show all 45
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADAL Building 404, W50S9F-21-R-0001
EXHIBIT A
PERFORMANCE RELEVANCY QUESTIONNAIRE AND COMPANY SPECIALIZED EXPERIENCE
PART 1: Prepare questionnaires in the format provided.
Provide the following information requested in this format for each of the projects/contracts being described. Prepare not more than five (5) of these documents. Contractors should select their projects carefully because the quality of the contractor’s relevant performance is more important than the quantity of projects submitted. Projects may be on going, if complete to 50 %, and cannot have been completed any earlier than 6 years prior to the solicitation issue date. Provide frank, concise comments regarding your performance on the contracts you identify. Use as much space as required.
A. Offeror (Your) Name (Company/Division):
B. Project/Contract Title:
C. Contract Specifics:
| 1. | Description of Effort as ___________Prime or _________Subcontractor |
| 2. | Contract Number: |
| 3. | Original Contract $ Value:_____________ Current/Final Contract $ Value:____________ |
| 4. | If amounts in 3 above are different, provide a brief description of the reason: |
5. Completion Date:
| a. | Original Date: |
| b. | Current Schedule: |
| c. | Estimated/Final Completion Date: |
| d. | Primary cause for Contract Modifications: |
D. Provide detailed description of the work performed under the contract including, but not limited to your past performance. Note that your description will be evaluated for similarity of the construction methods, particularly in construction projects for corrosion control, fuel cell hangars and flight simulators or equivalent facilities with similar characteristics to those identified in this solicitation. The Government may also consider similarity of the client type (i.e. federal government) and/or the project sustainability requirements. The location at which work was performed to the location(s) at which work will be performed may also be considered.
1. Describe the specific elements of the work performed by your firm.
2. Indicate what elements of work were performed by your major subcontractors and if those same subcontractors will be used on this project. If you intend to use these subcontractors, please list name and principal areas of work they will perform. A letter of commitment, as described in Section 00120, will be required for subcontractors.
3. Address any technical areas about this project you consider uniquely relevant to this project. Include in your discussion if project had sustainability requirements. Of particular interest are USGBC LEED® and the level of recognition received. Indicate if no such requirements.
4. If you intend to use any of the same key personnel on this solicitation’s project, indicate by name and position those personnel proposed to be utilized on the referenced contract. (Project Manager, Site Superintendent, Quality Control Manager). Indicate what position they will have on this solicitation’s contract. . A letter of commitment, as described in Section 00120, will be required for key subcontractors personnel.
5. Describe why you believe the work is very relevant, relevant or semi-relevant to this solicited project. (see section 00120 for information.) (Use as much space as necessary).
E. List a point of Contact for Owner/Government agency Contracting Officer and/or inspector; include a current phone number and email address. (This information is required here even though you will be sending Exhibit C letters and questionnaires to these references. (Do NOT include a copy of the Exhibit Cs you sent to your references.)
End of Part 1 - Questionnaire Requirements – Prepare and send Exhibit C Package to the reference(s) for each of projects discussed in the Exhibit As.
PART 2: Provide the following information one time.
Additional offeror information required, but not project specific. This information need only be provided once in your submission package.
2 A. Applicable to all offerors - Describe your compliance with the requirements of FAR clause 52.219-8 Utilization of Small Business Concerns. Even if you are a Small or Small Disadvantaged Business, this clause in Federal Contracts applies. It is the policy of the United States that small business concerns, veteran-owned small business concerns, service-disabled veteran-owned small business concerns, HUBZone small business concerns, small disadvantaged business concerns, and women-owned small business concerns shall have the maximum practicable opportunity to participate in performing contracts let by any Federal agency, including contracts and subcontracts for subsystems, assemblies, components, and related services for major systems. It is also policy to establish procedures to ensure the timely payment of amounts due pursuant to the terms of their subcontracts. Describe below the methods you have used to comply with this policy on prior federal contracts. Include any evidence, or a point of contact to verify this information, if available.
2B: Offerors are strongly encouraged to include with their proposals information on problems encountered on relevant projects and the specific corrective actions taken to remedy the problem(s).
2C: List any projects within the last six (6) years that have been assessed Liquidated damages. If none have been assessed, make a positive statement to that effect.
2D: List any projects within the last six (6) years that have been terminated, for any reason. Provide an explanation. If none, make a positive statement to that effect.
2E. Compliance with Safety Standards. Provide proof of your Experience Modification Rate (EMR) for these years: 2015, 2016, 2017, 2018 and 2019.
End of Questionnaire Requirements